2018-145 Landfill Landscape Buffer and Tree Planting UpdateDate: October 5, 2018 Report No. 2018-145
INFORMAL STAFF REPORT
TO MAYOR AND CITY COUNCIL
SUBJECT:
Update on landfill landscape buffer and tree planting
BACKGROUND:
During the October 16, 2018 City Council meeting, the Council will be asked to consider
approval of a contract with Fannin Tree Farm Sales, LLC for the supply and installation of trees
for City of Denton parks, medians, right of ways, and public buildings (Item 18-1669). The
proposed purchase agreement, totaling $1,206,000 over four (4) years, includes $406,000 to
install trees as part of a landscape buffer surrounding the Solid Waste Department’s landfill
operation. The below report provides a summary of the department’s buffer zone standards and
an overview of plans to improve the landscape buffer.
LANDSCAPE BUFFER:
In solid waste operations, buffer zones are typically utilized to restrict residential or commercial
use of property within a certain distance of waste disposal activity. For the Solid Waste
Department’s waste disposal operation, the buffer is 115 feet wide and runs parallel along
Mayhill Road from Edwards Road to Foster Road. An additional 100 foot wide buffer runs along
Edwards Road. The Solid Waste Department’s buffer zone includes landscaping and other
screening to separate operational activities from adjacent properties.
The standards for maintaining the buffer zone are outlined within Solid Waste’s Specific Use
Permit S-204. The permit requires “sufficient landscaping and screening to ensure harmony and
compatibility with adjacent property.” Following the Texas Commission on Environmental
Quality’s approval of Permit No. MSW 1590-A in 1999, the Solid Waste Department installed
an appropriate landscape buffer; however, portions of the vegetation died in the years that
followed.
Earlier this year, staff partnered with Freese & Nichols to redesign the landscape buffer and
irrigation system. The purpose of this effort was to create a design that remediates trees lost in
recent years while working around obstructions related to existing utility infrastructure, a future
DME transmission project, and Mayhill Road realignment. The planting and irrigation project is
broken into phases. Designs for the first two phases of the project are complete, and the proposed
contract with Fannin Tree Farm allows for the purchase of 358 trees annually. Staff’s goals are to
remediate 100% of previous onsite tree loss (approximately 560 trees), and capitalize on
opportunities to plant elsewhere onsite.
Date: October 5, 2018 Report No. 2018-145
TREE PLANTING SCHEDULE:
Because landscape design and tree planting is being attempted while several construction
projects are occurring in the area, the tree planting project is occurring in phases. Below is a brief
overview of each phase and the developments that must occur before final planting and
irrigation:
Phase 1– Located between the westernmost inactive landfill cell and the recently
installed screening wall, Solid Waste is anticipating the installation 90 canopy trees and
88 understory trees and plants consistent with a June 2018 design by Freese and Nichols
(Exhibit 1). Mobilization and tree installation is anticipated promptly (fall 2018), once
the proposed contract is approved. Installation of the permanent irrigation system will
occur with Phase 2 and 3. As a result, a temporary irrigation system will be installed as
part of Phase 1.
Phase 2 – Located in the eastern public way approximately along Mayhill Road, from
approximately Foster Rd to Old Edwards Road, Solid Waste is anticipating the
installation 39 canopy trees and 144 understory trees and plants consistent with an
August 2018 design by Freese and Nichols (Exhibit 2). Mobilization and installation of
trees and irrigation will occur upon the completion of the Mayhill Road realignment and
the installation of transmission lines associated with a DME capital project.
Phase 3 – Located in the public way adjacent to reconstructed Mayhill Rd. South of Old
Edwards Rd. Once the final alignment and subsequent design of Mayhill Road south of
Old Edwards Rd. is complete, landscape design will proceed, and installation will
commence as road construction is completed.
Please feel free to contact me if you have additional questions or concerns.
ATTACHMENT(S):
Exhibit 1 – Phase One Landfill Buffer Landscape Design
Exhibit 2 – Phase Two Landfill Buffer Landscape Design
STAFF CONTACT(S):
Ethan Cox, Director of Solid Waste
(940) 349-7421
Ethan.Cox@cityofdenton.com
Date:Plotter:$ACCOUNT$May. 31, 2018 - 03:15:07 PMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfg02543N:\arc\Phase One Landscape\Drawings\LA-MAYHILL RD-P1-CV-COVER.sht9999.9800 ft / in.Plot Scale:MicroStation V8 User:Date: May. 31, 2018 - 03:15:07 PM User:02543File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\arc\Phase One Landscape\Drawings\LA-MAYHILL RD-P1-CV-COVER.shtProject:Mayhill SouthDefaultModel:DTN18117
CITY OF DENTON, TEXAS
LOCATION
PROJECT
COUNCIL MEMBER.........................SARA BAGHERI
COUNCIL MEMBER......................DALTON GREGORY
COUNCIL MEMBER..........................JOEY HAWKINS
COUNCIL MEMBER................KATHLEEN WAZNEY
COUNCIL MEMBER............................KEELY BRIGGS
COUNCIL MEMBER.............................KEVIN RODEN
MAYOR.....................................................CHRIS WATTS
8000'4000'0
SCALE IN FEET
JUNE 2018
TEXAS REGISTERED ENGINEERING FIRM F-2144
CITY MANAGER.................................TODD HILEMAN
CITY ENGINEER.................................FRANK G. PAYNE, P.E.
PHASE ONE
LANDFILL BUFFER LANDSCAPE DESIGN
PLANTING LISTLA-5
PLANTING DETAILSLA-4
LANDSCAPE PLANTING PLANLA-3
LANDSCAPE PLANTING PLANLA-2
ORIENTATION PLANLA-1
SHEET INDEX
NOT FOR CONSTRUCTION
DATE:
THIS DOCUMENT IS RELEASED FOR THE
PURPOSE OF INTERIM REVIEW UNDER THE
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION.
AUTHORITY OF MATTHEW L. MILANO
TEXAS NO: 3028 JUNE 2018
ISSUED FOR REVIEW
IR-1 IRRIGATION PLANS
IR-2 IRRIGATION PLANS
IR-3 IRRIGATION DETAILS I
IR-4 IRRIGATION DETAILS II
IR-1 IRRIGATION PLANS
IR-2 IRRIGATION PLANS
IR-3 IRRIGATION DETAILS I
IR-4 IRRIGATION DETAILS II
F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET
SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMELA-MAYHILL RD- CV-P1-KEYMAP.shtISSUES2220 San Jacinto Blvd., Suite 330MAY 2018CITY OF DENTONDate:Plotter:$ACCOUNT$May. 31, 2018 - 05:06:42 PMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfg02543N:\arc\Phase One Landscape\Drawings\LA-MAYHILL RD- CV-P1-KEYMAP.sht159.9997 ' / in.Plot Scale:MicroStation V8 User:Date: May. 31, 2018 - 05:06:42 PM User:02543File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\arc\Phase One Landscape\Drawings\LA-MAYHILL RD- CV-P1-KEYMAP.shtProject:Mayhill SouthDefaultModel:DTN18117PHASE TWOLANDFILLE BUFFER LANDSCAPE DESIGNGWSGWSGWS
PROPOSED S MAYHILL ROAD
LA-2 LA-2 LA-3 LA-3
NOT FOR CONSTRUCTIONDATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THENOT FOR REGULATORY APPROVAL,PERMITTING OR CONSTRUCTION.AUTHORITY OF MATTHEW L. MILANOTEXAS NO: 3028JUNE 2018HHEAFEAFMLMLANDSCAPE ARCHITECTUREORIENTATION PLANLA-1PHASE ONE160'80'0 40'
SCALE IN FEET
1 OF 5
PHASE ONE
PHASE TWO
F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET
SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMELA-MAYHILL RD- PL-P1-LANDSCAPE 01.shtISSUES2220 San Jacinto Blvd., Suite 330MAY 2018CITY OF DENTONDate:Plotter:$ACCOUNT$May. 31, 2018 - 04:41:42 PMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfg02543N:\arc\Phase One Landscape\Drawings\LA-MAYHILL RD- PL-P1-LANDSCAPE 01.sht39.9999 ' / in.Plot Scale:MicroStation V8 User:Date: May. 31, 2018 - 04:41:42 PM User:02543File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\arc\Phase One Landscape\Drawings\LA-MAYHILL RD- PL-P1-LANDSCAPE 01.shtProject:Mayhill SouthDefaultModel:DTN18117PHASE TWOLANDFILLE BUFFER LANDSCAPE DESIGNWVFL=600.68Silted inICV610'595'
6
0
0'
595'
600'600'605'600'605'WVFL=592.9424"PVCFL=592.00FL=592.26WV0595
'600'605'BUFFER LIMIT
54' LANDSCAPE
BUFFER LIMIT
54' LANDSCAPE
100'-0"10' O.C. TYP.
10' O.C. TYP.
100'-0" SPECIES
TREE
TYP.
20' O.C.
TYP.
15' O.C.
EXISTING RETAINING WALL
EXISTING RETAINING WALL
EXISTING METAL FENCE
EXISTING METAL FENCE
MLMEAFMLMLA-2 LANDSCAPE PLANTING PLANS LANDSCAPE ARCHITECT EAF2 OF 5
40'20'0 10'
SCALE IN FEET
LEGEND
UNDERSTORY TREE
CANOPY TREE DATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OFTEXAS NO:IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMIT PURPOSES.NOT FOR CONSTRUCTION3028JUNE 2018MATTHEW L. MILANO7. CONTRACTOR TO REPAIR ANY DAMAGED TURF GRASS RESULTING FROM INSTALLATION AT NO EXPANSE TO OWNER.
PROPOSED TREE LOCATIONS\ AS NOT TO IMPACT EXISTING TREES.
6. IF ANY PROPOSED TREE LOCATIONS CONFLICT WITH EXISTING TREE LOCATIONS, THE CONTRACTOR SHALL SHIFT THE
5. DO NOT REMOVE ANY EXISTING TREES.
4. REFER TO PLANT LIST SHEET LA-5 FOR PLANT QUANTITIES, SIZE, AND SPECIES INFORMATION.
3. REFER TO SHEET LA-4 FOR PLANTING DETAILS.
2. THE CONTRACTOR SHALL VERIFY ALL EASEMENT LINES AND VISIBILITY LINES IN THE FIELD PRIOR TO CONSTRUCTION.
1. ALL DIMENSIONS ARE TO CENTER OF TREE UNLESS NOTED OTHERWISE.
GENERAL NOTES MATCHLINE BMATCHLINE AMATCHLINE AXX
CE CE CE CE CE
CE CE CE CE CE CE CE CE
CE CE CE CE CE
CE
CE
CE
CE CE CECECECECECECECECECECECECECECE
CE
CE
CE CE CE CE CE CE CE CE CE
CE
CE CE CE CE PHASE ONECE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE
CE CE CE CE
CE CE CE CE CE CE
CE CE CE CE
CE CE CE CE
CE CE CE CE CE CE
CE CE
CE CE
CE CE
CE CE CE CE CE CE
F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET
SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMELA-MAYHILL RD- PL-P1-LANDSCAPE 02.shtISSUES2220 San Jacinto Blvd., Suite 330MAY 2018CITY OF DENTONDate:Plotter:$ACCOUNT$May. 31, 2018 - 04:16:18 PMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfg02543N:\arc\Phase One Landscape\Drawings\LA-MAYHILL RD- PL-P1-LANDSCAPE 02.sht39.9999 ' / in.Plot Scale:MicroStation V8 User:Date: May. 31, 2018 - 04:16:18 PM User:02543File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\arc\Phase One Landscape\Drawings\LA-MAYHILL RD- PL-P1-LANDSCAPE 02.shtProject:Mayhill SouthDefaultModel:DTN18117PHASE TWOLANDFILLE BUFFER LANDSCAPE DESIGNICVICVICV610'615'WVWV615'620'615'620'615'
BUFFER LIMIT
54' LANDSCAPE
10' O.C. TYP.
100'-0" 10' O.C. TYP.
TYP.
20' O.C.
TYP.
15' O.C.
100'-0"
SPECIES
TREE
BUFFER LIMIT
54' LANDSCAPE
EXISTING METAL FENCE
TYP.
20' O.C.
TYP.
15' O.C.
EXISTING RETAINING WALL
EXISTING RETAINING WALL
EXISTING METAL FENCE
MLMEAFMLMLA-3 LANDSCAPE PLANTING PLANS LANDSCAPE ARCHITECT EAF3 OF 5
40'20'0 10'
SCALE IN FEET
LEGEND
UNDERSTORY TREE
CANOPY TREE DATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OFTEXAS NO:IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMIT PURPOSES.NOT FOR CONSTRUCTIONMATTHEW L. MILANO3028JUNE 2018MATCHLINE CMATCHLINE BMATCHLINE C7. CONTRACTOR TO REPAIR ANY DAMAGED TURF GRASS RESULTING FROM INSTALLATION AT NO EXPANSE TO OWNER.
PROPOSED TREE LOCATIONS\ AS NOT TO IMPACT EXISTING TREES.
6. IF ANY PROPOSED TREE LOCATIONS CONFLICT WITH EXISTING TREE LOCATIONS, THE CONTRACTOR SHALL SHIFT THE
5. DO NOT REMOVE ANY EXISTING TREES.
4. REFER TO PLANT LIST SHEET LA-5 FOR PLANT QUANTITIES, SIZE, AND SPECIES INFORMATION.
3. REFER TO SHEET LA-4 FOR PLANTING DETAILS.
2. THE CONTRACTOR SHALL VERIFY ALL EASEMENT LINES AND VISIBILITY LINES IN THE FIELD PRIOR TO CONSTRUCTION.
1. ALL DIMENSIONS ARE TO CENTER OF TREE UNLESS NOTED OTHERWISE.
GENERAL NOTES
TO REMAIN
EXISTING TREE
XX
CECECE
CE CE CE CE CE CE CE CE CE CE CE CE CE
CE CE CE CE
CE CE CE CE CE CE CE CE CE CE CE CE CE
CE CE CE CE CE CE CE
CE
CE CE CE CE CE CE CE CE CE CE
CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE CE
PHASE ONE
F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET
SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMELA-MAYHILL RD- DT-P1-PLANT.shtISSUES2220 San Jacinto Blvd., Suite 330MAY 2018CITY OF DENTONDate:Plotter:$ACCOUNT$May. 31, 2018 - 03:31:09 PMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfg02543N:\arc\Phase One Landscape\Drawings\LA-MAYHILL RD- DT-P1-PLANT.sht20.0000 ' / in.Plot Scale:MicroStation V8 User:Date: May. 31, 2018 - 03:31:09 PM User:02543File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\arc\Phase One Landscape\Drawings\LA-MAYHILL RD- DT-P1-PLANT.shtProject:Mayhill SouthDefaultModel:DTN18117PHASE TWOLANDFILLE BUFFER LANDSCAPE DESIGNPLANT CROWN AT GRADE
3" MULCH
TEMPORARY TREE WELL
FINISH GRADE
BACKFILL PLANTING PIT WITH SURFACE LAYER
PREPARED PLANTING SOIL MIX AS SPECIFIED
SCARIFY SURFACE PRIOR TO BACKFILLING
TO IMPROVE ROOT PENETRATION
TAMP TO PREVENT SETTLEMENT
TREE
CENTERED
IN
HOLE
NOTES:
1.TREE PLANTINGS IN THE HARDWOOD MULCH BEDS
TO RECEIVE 3" SHREDDED HARDWOOD MULCH,
UNIFORM COVERAGE. (SEE PLANS FOR TREE
LOCATIONS)
PLANT CROWN AT GRADE
3" MULCH
TEMPORARY TREE WELL
FINISH GRADE
BACKFILL PLANTING PIT WITH PREPARED
PLANTING SOIL MIX AS SPECIFIED
SCARIFY SURFACE PRIOR TO BACKFILLING
TO IMPROVE ROOT PENETRATION
TAMP TO PREVENT SETTLEMENT
PLANTING SOIL MIXTURE EQUALS
THREE (3) PARTS EXISTING SOIL
AND ON (1) PART FINELY
GROUND HARDWOOD MULCH,
THOROUGHLY MIXED
TREE
CENTERED
IN
HOLE
1/2 INCH DIA. X 36
INCH LONG NAIL
STAKES WITH ANGLED
TIP AT BOTTOM
MULCH TO BE PLACED 3"
AWAY FROM TREE TRUNK
PLANTING SOIL MIXTURE EQUALS
THREE (3) PARTS EXISTING SOIL
AND ON (1) PART FINELY
GROUND HARDWOOD MULCH,
THOROUGHLY MIXED
(3) T-POSTS WITH POST CAPS
ARBOR TIE TREE STAKING MATERIAL
(3) T-POSTS WITH POST CAPS
ARBOR TIE TREE STAKING MATERIAL
NOTES:
WITH THE CITY.
INSTALLATION SHALL BE COORDINATED
2. ALL TREE PRUNING AT THE TIME OF
SEASON.
REMOVED AFTER ONE FULL GROWING
ANCHORS AND ARBOR TIE TO BE
1. TEMPORARY TREE WELL, TREE
(3) T-POSTS WITH POST CAPS
ARBOR TIE TREE STAKING MATERIAL
PLANT CROWN AT GRADE
3" MULCH
TEMPORARY TREE WELL
FINISH GRADE
BACKFILL PLANTING PIT WITH PREPARED
PLANTING SOIL MIX AS SPECIFIED
SCARIFY SURFACE PRIOR TO BACKFILLING
TO IMPROVE ROOT PENETRATION
TAMP TO PREVENT SETTLEMENT
UNDISTURBED SUBGRADE
TREE
CENTERED
IN
HOLE
NOTES:
LOCATIONS)
COVERAGE. (SEE PLANS FOR HARDWOOD MULCH BED
RECEIVE 3" SHREDDED HARDWOOD MULCH, UNIFORM
1. TREE PLANTINGS IN THE HARDWOOD MULCH BEDS TO
1'-0"3" MIN.6" (TYP.)
6" (TYP.)3" MIN.1'-0"
6" (TYP.)3" MIN.1'-0"MLMEAFMLMLA-4LANDSCAPE ARCHITECT EAF4 OF 5DATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OFTEXAS NO:IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMIT PURPOSES.NOT FOR CONSTRUCTIONMATTHEW L. MILANO3028JUNE 2018PLANTING DETAILSON ALL SIDES
1' MIN. CLEARANCE
2 TIMES CONTAINER SIZE
ON ALL SIDES
1' MIN. CLEARANCE
2 TIMES CONTAINER SIZE
1
NOT TO SCALELA-4
2
NOT TO SCALELA-4
CANOPY TREE PLANTING AND STAKING DETAIL
3
NOT TO SCALELA-4
UNDERSTORY EVERGREEN TREE PLANTING AND STAKING DETAIL
UNDERSTORY MULTI-TRUNK TREE PLANTING AND STAKING DETAIL
ON ALL SIDES
1' MIN. CLEARANCE
2 TIMES CONTAINER SIZE PHASE ONET-POSTS
F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET
SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMELA-MAYHILL RD- DT-P1-PLANTLIST.shtISSUES2220 San Jacinto Blvd., Suite 330MAY 2018CITY OF DENTONDate:Plotter:$ACCOUNT$May. 31, 2018 - 03:25:40 PMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfg02543N:\arc\Phase One Landscape\Drawings\LA-MAYHILL RD- DT-P1-PLANTLIST.sht20.0000 ' / in.Plot Scale:MicroStation V8 User:Date: May. 31, 2018 - 03:25:40 PM User:02543File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\arc\Phase One Landscape\Drawings\LA-MAYHILL RD- DT-P1-PLANTLIST.shtProject:Mayhill SouthDefaultModel:DTN18117PHASE TWOLANDFILLE BUFFER LANDSCAPE DESIGN PLANT SCHEDULE
SYMBOL PERCENTAGE SIZE COMMON NAME BOTANICAL NAME CONDITION COMMENTS
CANOPY TREE
SG #65 CLASS MINIMUM SWEETGUM LIQUIDAMBER STYRACIFLUA CONTAINER FEET; FULL DENSE CANOPY; MATCH SELECTIONS FOR UNIFORM HEIGHT AND SPREAD
MINIMUM TRUNK DIAMETER 3 INCHES; MINIMUM SPREAD SIX FEET; MINIMUM HEIGHT TWELVE
RC #65 CLASS MINIMUM RED CEDAR JUNIPERUS VIRGINIANA CONTAINER FEET; FULL DENSE CANOPY; MATCH SELECTIONS FOR UNIFORM HEIGHT AND SPREAD
MINIMUM TRUNK DIAMETER 3 INCHES; MINIMUM SPREAD SIX FEET; MINIMUM HEIGHT TWELVE
AP #65 CLASS MINIMUM AFGHAN PINE PINUS ELDARICA CONTAINER FEET; FULL DENSE CANOPY; MATCH SELECTIONS FOR UNIFORM HEIGHT AND SPREAD
MINIMUM TRUNK DIAMETER 3 INCHES; MINIMUM SPREAD SIX FEET; MINIMUM HEIGHT TWELVE
BO #65 CLASS MINIMUM BURR OAK QUERCUS MACCROCARPA CONTAINER FEET; FULL DENSE CANOPY; MATCH SELECTIONS FOR UNIFORM HEIGHT AND SPREAD
MINIMUM TRUNK DIAMETER 3 INCHES; MINIMUM SPREAD SIX FEET; MINIMUM HEIGHT TWELVE
LE #65 CLASS MINIMUM LACEBARK ELM ULUMUS PARVIFOLIA CONTAINER FEET; FULL DENSE CANOPY; MATCH SELECTIONS FOR UNIFORM HEIGHT AND SPREAD
MINIMUM TRUNK DIAMETER 3 INCHES; MINIMUM SPREAD SIX FEET; MINIMUM HEIGHT TWELVE
PE #65 CLASS MINIMUM PECAN CARYA ILLINOISENSIS CONTAINER FEET; FULL DENSE CANOPY; MATCH SELECTIONS FOR UNIFORM HEIGHT AND SPREAD
MINIMUM TRUNK DIAMETER 3 INCHES; MINIMUM SPREAD SIX FEET; MINIMUM HEIGHT TWELVE
RB #65 CLASS MINIMUM RIVER BIRCH BETULA NIGRA CONTAINER FEET; FULL DENSE CANOPY; MATCH SELECTIONS FOR UNIFORM HEIGHT AND SPREAD
MINIMUM TRUNK DIAMETER 3 INCHES; MINIMUM SPREAD SIX FEET; MINIMUM HEIGHT TWELVE
UNDERSTORY TREE
AV #45 CLASS MINIMUM ARBOR VITAE THUGA ACCIDENTAILS CONTAINER SELECTIONS FOR UNIFORM HEIGHT AND SPREAD
MINIMUM SPREAD, FIVE FEET; MINIMUM HEIGHT TEN FEET; FULL DENSE CANOPY; MATCH
EP #45 CLASS MINIMUM EAST PALATKA HOLLY ILEX EAST PALATKA CONTAINER SELECTIONS FOR UNIFORM HEIGHT AND SPREAD
MINIMUM SPREAD, FIVE FEET; MINIMUM HEIGHT TEN FEET; FULL DENSE CANOPY; MATCH
MR #45 CLASS MINIMUM MEXICAN/ OKLAHOMA REDBUD
MEXICANA OR 'OKLAHOMA'
CERCIC CANADENSIS VAR.
CONTAINER SELECTIONS FOR UNIFORM HEIGHT AND SPREAD
MINIMUM SPREAD, FIVE FEET; MINIMUM HEIGHT TEN FEET; FULL DENSE CANOPY; MATCH
MP #45 CLASS MINIMUM MEXICAN PLUM PRUNUS MEXICANA CONTAINER SELECTIONS FOR UNIFORM HEIGHT AND SPREAD
MINIMUM SPREAD, FIVE FEET; MINIMUM HEIGHT TEN FEET; FULL DENSE CANOPY; MATCH
SH #45 CLASS MINIMUM STEVENS HOLLY ILEX NELLI R STEVENS CONTAINER SELECTIONS FOR UNIFORM HEIGHT AND SPREAD
MINIMUM SPREAD, FIVE FEET; MINIMUM HEIGHT TEN FEET; FULL DENSE CANOPY; MATCH
PH #45 CLASS MINIMUM POSSUMHAW HOLLY ILEX DECIDUA CONTAINER SELECTIONS FOR UNIFORM HEIGHT AND SPREAD
MINIMUM SPREAD, FIVE FEET; MINIMUM HEIGHT TEN FEET; FULL DENSE CANOPY; MATCH
INDICATED IN THE PLANT LIST MAY BE NECESSARY TO PROVIDE THE OTHER MINIMUM CRITERIA INDICATED.
CRITERIA REQUIRED. A CONTAINER SIZE LARGER THAN THE MINIMUM SIZE CONTAINER MINIMUM1). ALL SIZES SHOWN FOR ALL PLANTS (SUCH AS CALIPER, CONTAINER SIZE, SPREAD, HEIGHT, BRANCHING HEIGHT, ETC.) ARE THE
NOTE: MLMEAFMLMLA-5LANDSCAPE ARCHITECT EAF5 OF 5DATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OFTEXAS NO:IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMIT PURPOSES.NOT FOR CONSTRUCTIONMATTHEW L. MILANO3028JUNE 2018PLANTING LIST18
18
18
9
9
9
8
22
22
13
13
9
9 PHASE ONE
F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET
SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMEIR-MAYHILL RD- PL-P1-Irrigation 01.shtISSUES2220 San Jacinto Blvd., Suite 330MAY 2018CITY OF DENTONDate:Plotter:$ACCOUNT$Jun. 14, 2018 - 07:51:10 AMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfgtmgN:\plbg\Phase 1\IR-MAYHILL RD- PL-P1-Irrigation 01.sht20.0000 ' / in.Plot Scale:MicroStation V8 User:Date: Jun. 14, 2018 - 07:51:10 AM User:tmg File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\plbg\Phase 1\IR-MAYHILL RD- PL-P1-Irrigation 01.shtProject:Mayhill SouthDefaultModel:DTN18117PHASE TWOLANDFILL BUFFER LANDSCAPE DESIGNWVWVutilityvaultICVmonitoringwellmonitoringwellFL=600.68Silted inWVWarning SignFiber OpticMarkerWater LineMarkerWater LineFL=592.9424"PVCFL=592.00FL=592.26monitoringwellWV0WVWVutilityvaultICVmonitoringwellmonitoringwellM
WVmonitoringwellWV0EXISTING RETAINING WALL
EXISTING RETAINING WALL
EXISTING METAL FENCE
EXISTING METAL FENCE
CONTROLLER
IRRIGATION
IRRIGATION
PHASE 1
FOR
VALVE
ISOLATION
REUSE WATER SUPPLY TO BE USED FOR IRRIGATION
FIELD VERIFY LOCATION OF EXISTING
PHASE 2 IRRIGATION
ISOLATION VALVES FOR RJKTMGTMGIR-1
TMG- OF -
40'20'0 10'
SCALE IN FEETMATCHLINE BMATCHLINE AMATCHLINE APHASE ONEIRRIGATIONIRRIGATION PLANGENERAL NOTES:
NOTE BY SYMBOL " ":
2
3 TYP.
3 TYP.
2
2
NOTE TO CONTRACTOR
PRIOR TO CONSTRUCTION
DEPARTMENT FOR APPROVAL
PLANS TO PERMIT
IRRIGATOR MUST SUBMIT
REFER TO IR-3 FOR GENERAL NOTES AND DETAILS.1.
2
2
3TYP.
3 TYP.
PROVIDE TREE RING AT EACH NEW TREE AND NEW SHRUB CLUSTER.3.
AND ROADWAYS PER CITY OF DENTON STANDARDS.
MAIN. SLEEVE RIGID PVC BENEATH WALKS, DRIVES
DRIP LINE IRRIGATION SYSTEM WATER SUPPLY 2.
REUSE WATER SUPPLY PER CITY OF DENTON STANDARDS.
IRRIGATION SYSTEM WATER SUPPLY. TAP INTO 1.DATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OFTEXAS NO:IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMIT PURPOSES.NOT FOR CONSTRUCTION3279ROBERT J. KINKEL6/14/18
F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET
SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMEIR-MAYHILL RD- PL-P1-Irrigation 02.shtISSUES2220 San Jacinto Blvd., Suite 330MAY 2018Date:Plotter:$ACCOUNT$Jun. 14, 2018 - 07:57:32 AMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfgtmgN:\plbg\Phase 1\IR-MAYHILL RD- PL-P1-Irrigation 02.sht20.0000 ' / in.Plot Scale:MicroStation V8 User:Date: Jun. 14, 2018 - 07:57:32 AM User:tmg File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\plbg\Phase 1\IR-MAYHILL RD- PL-P1-Irrigation 02.shtProject:Mayhill SouthDefaultModel:DTN18117Warning SignFiber OpticICVICVICVmonitoringwellWVWVmonitoringwellWVWVmonitoringwellICVICVICVmonitoringwellEXISTING METAL FENCE
EXISTING RETAINING WALL
STATION VALVE
MLMEAFMLMIR-2 EAF- OF -
40'20'0 10'
SCALE IN FEETMATCHLINE CMATCHLINE BMATCHLINE CIRRIGATIONIRRIGATION PLANSNOTE BY SYMBOL " ":
NOTE TO CONTRACTOR
PRIOR TO CONSTRUCTION
DEPARTMENT FOR APPROVAL
PLANS TO PERMIT
IRRIGATOR MUST SUBMIT
2 TYP.
2 TYP.
2
GENERAL NOTES:
REFER TO IR-3 FOR GENERAL NOTES AND DETAILS.1.
2 TYP.
PROVIDE TREE RING AT EACH NEW TREE AND NEW SHRUB CLUSTER.2.
AND ROADWAYS PER CITY OF DENTON STANDARDS.
MAIN. SLEEVE RIGID PVC BENEATH WALKS, DRIVES
DRIP LINE IRRIGATION SYSTEM WATER SUPPLY 1.
TYP.
1
1 DATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OFTEXAS NO:IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMIT PURPOSES.NOT FOR CONSTRUCTION3279ROBERT J. KINKEL6/14/18CITY OF DENTONPHASE TWOLANDFILL BUFFER LANDSCAPE DESIGNPHASE ONE
1
XFS-CV ON-SURFACE DRIPLINE INSERT ADAPTER
FOR 1" OR LARGER PVC
3
XFS-CV SUB-SURFACE/ON-SURFACE DRIPLINE
MULTIPLE TREE RING LAYOUT SIDE FED
2
XFS-CV SUB-SURFACE/ON-SURFACE DRIPLINE
QUICK LOOP LAYOUT-MEDIAN ISLAND DOWN SLOPE
2"-4"F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET
SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMEir-MAY-dt-detail01.dgnISSUESDTN103042220 San Jacinto Blvd., Suite 330AUG 2017N.T.S.
4
3
2
1
1 2
OF DIRECTION.
OR ELBOWS, USE TIE-DOWN STAKES ON EACH LEG OF THE CHANGE
2. AT FITTINGS WHERE THERE IS A CHANGE OF DIRECTION SUCH AS TEES
LOAM, AND FIVE FEET IN CLAY.
1. PLACE TIE DOWN STAKES EVERY THREE FEET IN SAND, F0UR FEET IN
NOTES:
3 4
5
6
7
6
5
10
8
7
98
109
N.T.S.
FP FP FP
1
2
3
4
5
6
7
8
9
OP
1
2
3
4
5
6 7
89
10
11
10
11
NOTES:
1.FOR ALL XFS-CV AND POLY CONNECTIONS INSTALL XFF AND/OR XFD FITTINGS
2.SEE XFS-CV TREE RING DOUBLE OR TRIPLE FOR DETAIL OF EACH SET OF RINGS.
3.FOR TOTAL SYSTEM FLOW GREATER THAN 5 GPM USE PVC TO CONNECT TREE RINGS,
DOUBLE OR TRIPLE, AND SIZE PVC APPROPRIATELY.
N.T.S.
RAIN BIRD TDS-050 WITH BEND
TIE DOWN STAKE:
RAIN BIRD XFD-CROSS (TYPICAL)
BARB X BARB INSERT CROSS:
INSTALLED IN VALVE BOX
RAIN BIRD XCZ DRIP CONTROL ZONE KIT
:IRRIGATION CONTROL VALVE
FLOW)
PVC SUPPLY HEADER (SIZE BASED ON TOTAL
RAIN BIRD MODEL: OPERIND
OPERATION INDICATOR
RECOMMENDATION
XFS-CV SPACING PER RAIN BIRD
NON-POTABLE: XFS-CVP DRIPLINE
RAIN BIRD XFS-CV SERIES DRIPLINE (TYPICAL)
SUB-SURFACE/ON-SURFACE DRIPLINE:
TREE TRUNK
RAIN BIRD XF SERIES BLANK TUBING
SEE RAIN BIRD DETAIL "XFS-CV FLUSH POINT"
FLUSH POINT (TYPICAL)
SQUARE CONFIGURATION
MINIMUM 1" IN DIAMETER
PVC LATERAL PIPE
1"X1"X1/2" SST PVC TEE
TWIST LOCK FITTING : TLF-MPT6-0600
RAIN BIRD XFD SERIES BLANK TUBING
1/2" POLYETHYLENE TUBING:
FINISH GRADE
MULCH
BEND (TYPICAL)
TIE DOWN STAKE: RAIN BIRD TDS-050 WITH
INLINE DRIP EMITTER OUTLET
NON-POTABLE: XFS-CVP DRIPLINE
(TYPICAL)
RAIN BIRD XFS-CV SERIES DRIPLINE
ON-SURFACE DRIPLINE:
TWIST LOCK FITTING : TLF-TEE 0600
RJKTMGTMGTMGIRRIGATION DETAILS IIR-3
GENERAL NOTES:
WITH A SINGLE 1/2" FLUSHING HEADER. PROVIDE WITH END OF MAIN FLUSH POINT VALVE IN VALVE BOX.
FOR ALL SHRUB BEDS AND SMALL TURF AREAS, EXTEND DRIP LINE THROUGH THESE AREAS. SUPPLY SHRUB BEDS 10.
OR METER BOX.
TO PROVIDE THE MINIMUM PRESSURE AT THE FURTHEST STATION. INSTALL THE PRV IN A LARGE DIAMETER TURF
AND DELIVERING MINIMUM OF 50 PSIG DOWNSTREAM OF THE PRV. ADJUST THE DISCHARGE PRESSURES OF THE PRV
A PRESSURE REGULATOR (PRV) CAPABLE OF RECEIVING THE ACTUAL INLET PRESSURE OBTAINED FROM THE CITY
THE MINIMUM PRESSURE AT THE FURTHEST POINT IN THE DRIP SYSTEM OR RZWS IS 40 PSIG. THEREFORE PROVIDE
THE BASIS OF DESIGN IS THAT THE MINIMUM PRESSURE AVAILABLE AT EACH STATION VALVE EXCEEDS 50 PSIG. 9.
COMPLIANCE REPORTS TO THE OWNER IN THE O & M MANUALS.
ALL ELECTRICAL COMPONENTS OF THE SYSTEM. TEST THE SYSTEM TO INSURE COMPLIANCE AND PROVIDE
PROVIDE GROUNDING RODS OR SYSTEMS IN ACCORDANCE WITH THE 2016 NATIONAL ELECTRICAL CODE (NEC) FOR 8.
ON THE ACTUAL DESIGN PROVIDED BY THE LANDSCAPE IRRIGATION CONTRACTOR.
PIPE SIZES INDICATED ARE THE MINIMUM SIZES AND ARE FOR BIDDING PURPOSES ONLY. PROVIDE PIPE SIZES BASED 7.
AND OTHER OBSTRUCTIONS.
PIPE ROUTING SHOWN IS DIAGRAMMATIC. LOCATE PIPING, VALVES, AND FITTINGS TO AVOID EXISTING TREE ROOTS, 6.
OF CENTER FEED SYSTEMS. LOOP ENDS OF ALL DRIPLINE SYSTEMS.
DRIP SYSTEMS BASIS OF DESIGN SHALL BE RAINBIRD DRIPLINE. MAXIMIZE FLOW AND PRESSURE THROUGH THE USE 5.
BOXES SHALL BE RATED FOR H20 LOADS.
DIAMETER, OR OLDCASTLE MODEL 1324 POLYMER VALVE BOX WITH SINGLE PIECE STEEL COVER. ALL VAULTS AND
VALVE BOXES SHALL BE NO LESS STRINGENT THAN OLDCASTLE FIBRELYTE MODEL FL08 COMPOSITE 9 INCH
HEAVY DUTY, COMMERCIAL GRADE IN CONFORMANCE TO THE CFW STANDARDS, CONTROL VALVE AND SHUT OFF
METER VAULTS, BACKFLOW PREVENTER VAULTS, MANUAL SHUT OFF AND CONTROL VALVE BOXES SHALL BE 4.
LICENSED LANDSCAPE IRRIGATORS DRAWINGS, PERMITS, INSPECTIONS, ETC, SHALL BE INCLUDED IN THE BID.
DESIGNING THE SYSTEM AND COMPLY THEREIN. PROVISIONS FOR TAPPING FEES, PLANS EXAMINATIONS OF THE
COORDINATE METERING AND BACKFLOW PREVENTION REQUIREMENTS WITH THE CITY OF DENTON PRIOR TO 3.
TO THE PUBLISHED MANUFACTURERS STANDARDS.
EVERY VOID TO MAKE THE SLEEVE WATER-TIGHT. DRIP AND RZWS SHALL BE PROVIDED IN STRICT CONFORMANCE
PVC SLEEVES WITH 25 YEAR CLEAR SILICONE, A MINIMUM OF 4 INCHES INTO EACH SLEEVE END AND TO FILL
40 RIGID PVC PIPE , ONE INCH DIAMETER NOMINAL PIPE, OR AS REQUIRED BY THE CFW STANDARDS. SEAL ENDS OF
LARGER THAN THE PIPE OR TUBING. LOW VOLTAGE CONDUCTORS SHALL BE SLEEVED IN NO LESS THAN SCHEDULE
IN CONFORMANCE WITH THE CFW STANDARDS, NO LESS STRINGENT THAN SCHEDULE 80 RIGID PVC TWO SIZES
TURFAND SHRUBS. PROVIDE RIGID PVC SLEEVES BETWEEN DRIP STATIONS, BENEATH ROADWAYS, DRIVES AND WALKS
PROVIDE ROOT ZONE WATERING SYSTEMS (RZWS) FOR ALL TREES (2 EACH) AND DRIPLINE IRRIGATION FOR ALL 2.
IRRIGATION FOR ALL NEW LANDSCAPE PRODUCTS.
COORDINATE WITH THE LANDSCAPE DRAWINGS FOR EXACT LOCATION OF ALL COMPONENTS AND PROVIDE
WITH THE TXDOT STANDARDS AND REQUIREMENTS. RESIDENTIAL GRADE PRODUCTS ARE NOT PERMITTED.
OPERABLE COMMERCIAL GRADE LANDSCAPE IRRIGATION SYSTEM FOR ALL LANDSCAPE PRODUCTS IN CONFORMANCE
BASED DESIGN SPECIFICATION, WHERE CONFLICTS EXIST THE MORE STRINGENT SHALL APPLY. PROVIDE A COMPLETE
ARCHITECT/ENGINEER AS SHOP DRAWINGS. THE SPECIFICATIONS ARE AN INTEGRAL PART OF THIS PERFORMANCE
SYSTEM FUNCTIONAL, SUBMIT THE DRAWINGS TO DENTON FOR APPROVAL BEFORE SUBMITTING TO THE
VALVES, PIPE AND FITTINGS, RZWS AND DRIP SYSTEMS INCLUDING EVERY APPURTENANCE REQUIRED TO MAKE THE
CONTRACTOR SHALL PROVIDE A COMPLETE DESIGN, INCLUDING EACH AND EVERY COMPONENT OF THE CONTROLS,
OF THE SYSTEM INCLUDING BASIC ROUTING, TYPE OF SYSTEM REQUIRED AND SPECIFICATIONS OF COMPONENTS. THE
THE SYSTEMS INDICATED ON THESE DRAWINGS ARE A PERFORMANCE BASED DESIGN, PROVIDING THE PARAMETERS 1.
- OF -DATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OFTEXAS NO:IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMIT PURPOSES.NOT FOR CONSTRUCTION3279ROBERT J. KINKEL6/14/18CITY OF DENTONPHASE TWOLANDFILL BUFFER LANDSCAPE DESIGNPHASE ONE
5
XFCV ON-SURFACE DRIPLINE
SLOPED LAYOUT
6
XFS-CV SUB-SURFACE/ON-SURFACE DRIPLINE
TYPICAL ISLAND LAYOUT W/ PVC HEADERS
12"1.33
8".53
1
2
4
3
5
6 8 97
BLACK WIRE
x
x+
x
x+
SLOPE SPACING
BOTTOM 1/3 OF
NORMAL SPACING
TOP 2/3 OF SLOPE
xxxxxxxx x
x+
x
(Feet)
XFCV Dripline Maximum Lateral Lengths
Inlet Pressure psi
12" Spacing 18" Spacing
Nominal Flow (gph)Nominal Flow (gph)
0.6 0.9 0.6 0.9
20 192 136 254 215
30 289 205 402 337
40 350 248 498 416
50 397 281 573 477
60 436 309 637 529
x
x+
BURIAL DEPTH
DRIP MANIFOLD
(Feet)
XFS-CV Dripline Maximum Lateral Lengths
Inlet Pressure psi
12" Spacing 18" Spacing
Nominal Flow (gph)Nominal Flow (gph)
0.6 0.9 0.6 0.9
20 192 136 254 215
30 289 205 402 337
40 350 248 498 416
50 397 281 573 477
60 436 309 637 529 F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET
SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMEir-MAY-dt-detail02.dgnISSUESDTN103042220 San Jacinto Blvd., Suite 330AUG 2017 RJKTMGTMGTMGIRRIGATION 1 LEIT CONTROLLER MODEL LEIT 4000
6 FINISH GRADE
1
2
3
4
6
5
MODEL 30-405
2 HIGH SECURITY STAINLESS STEEL DISC-LOCK
7
NOT TO SCALE
CONCRETE
BASE USING 90 Lb. (40 kg) BAG OF
5 12" X 18" (30 x 45 cm) CONCRETE
CONTROL VALVES.
7 DIRECT BURIAL CONTROL WIRES TO
MOUNTING MODEL ENCL 4000
AND INTERNAL CLAMP TO SECURE COLUMN
WITH LIGHT ACCESS THROUGH GRID ON TOP
3 HEAVY-DUTY STAINLESS STEEL ENCLOSURE
FOR LEIT 4000 AND 4000E
4 GALVANIZED STEEL MOUNTING COLUMN
a. MODEL MCOL 4000 32" (81 cm) SHORT
b. MODEL MCOL 4000L 48" (124 cm) LONG
6 to 10 FEET HIGH.
5 1" or 1.5" GALVANIZED PIPE
VALVE BOX.
9 6" ROUND
FROM SENSOR.
13 NORMALLY CLOSED WIRE
RAIN SENSOR.
1 "MINI CLIK"
WITH HOLE FOR WIRES.
1.5" CAP PART No. 23-053
1" CAP PART No. 23-001 or
2 DIG PLASTIC PIPE CAP
FROM SENSOR.
14 COMMON WIRE
11 TO CONTROLLER OR VALVE.
8" DEEP MINIMUM.
6 12" X 12" CONCRETE BASE
AND NUT.
WITH WASHER, LOCK WASHER
4 (2) #8-32 MACHINE SCREWS
FOR SENSOR BRACKET.
3 DRILL TWO 3/16 HOLES IN PIPE
SKIT
8 FINISH GRADE.
16 GRAVEL.
CONNECTORS.
12 (4) DRY SPLICE
2
LEGEND
7 1" or 1.5" PIPE ELBOW.
15 1"or 1.5" NIPPLE.
USE WITH EACH SENSOR.
PART NO. 8821-4
10 SKIT ADAPTER
16
15
14 13 12 11
10
NOT TO SCALE
WHITE WIREBLACK WIRE
RED WIRE
9
6
8
7
5
4
11111111111
3
2
2
5
6
8
10
11
VALVE BOX WITH COVER
12" SIZE
FINISH GRADE TOP
DIG LEIT 3/4" REMOTE
MODEL P52-075 (30 PSI)
PVC LATERAL LINE
PEA GRAVEL SUMP
MINIMUM 3"
BRICK SUPPORT AT EACH
CORNER
7
10
11
3 4
9
12 SCH 40 TEE
PVC SCH 40 90 DEGREE
ELL
13
12
1
13
23-004 1" F X 3/4" M
MAIN SUPPLY LINE
SWIVEL FITTING DIG MODEL
CONTROL WIRE TO OTHER VALVE
WIRE CONNECTORS
CONTROL VALVE ASSEMBLY
3/4" FEMALE NPT
COUPLING x SLIP
NOT TO SCALE
2 31
MINIMUM2"6
8
5
4
DRY SPLICE CONNECTORS.
4 DIG VALVE MODEL
3/4" 160HE - 075
1" 160HE - 100
7
9
10
11
12
13
10
11
12
13 12 OR 14 GAUGE WIRE.
REMOTE CONTROL VALVE FOR LEIT CONTROLLER
1
2
3
5
6
7
8
9
SIZE.
VALVE BOX WITH COVER 18"
FINISH GRADE TOP.
SWIVEL FITTING DIG MODEL
3/4" 23-004, 1" 23-003.
PVC SCH 40 MALE ADAPTER.
PVC LATERAL LINE.
BRICK SUPPORT AT EACH CORNER.
PEA GRAVEL SUMP - MINIMUM 3".
BACK-UP NPT PVC BALL VALVE.
PVC SCH 40 90 DEGREE ELL.
SCH 40 TEE.
LEGEND
160HE-075 3/4" AND 160HE-100 1"
NOT TO SCALE
RAIN SENSOR ASSEMBLY (COLUMN MOUNTED)
USING SKIT 8821-4 RAIN SENSOR
4000
STAINLESS STEEL ENCLOSURE MODEL ENCL
ACCESSIBLE STAINLESS STEEL ENCLOSURE
LEIT 4000 AND 4000E WITH LIGHT DRIP ZONE ASSEMBLY FOR LEIT SYSTEM
3/4" PRESET 30 PSI P52-075
DETAILS IIINSTALLED ON EACH FITTING.
50PSI, IT IS RECOMMENDED THAT STAINLESS STEEL CLAMPS BE
WHEN USING 17MM INSERT FITTINGS WITH DESIGN PRESSURE OVER 4.
THAT A NEW DRIPLINE ZONE BE CREATED.
3. WHEN ELEVATION CHANGE EXCEEDS 10 FEET IT IS RECOMMENDED
MAXIMUM LENGTH SHOWN IN THE ACCOMPANYING TABLE.
2. LENGTH OF LONGEST DRIPLINE LATERAL SHOULD NOT EXCEED THE
SPACING.
SEE RAIN BIRD XFD DRIPLINE INSTALLATION GUIDE FOR SUGGESTED
OF SLOPE TO BE SPACED GREATER THAN OPTIMAL ROW DISTANCE.
ELEVATION. DISTANCE BETWEEN LATERAL ROWS FOR BOTTOM 1/3
BASED ON SOIL TYPE, PLANT MATERIALS AND CHANGES IN
1. DISTANCE BETWEEN LATERAL ROWS AND EMITTER SPACING TO BE
NOTES:
PVC FLUSH HEADER
FOR FLUSH POINT INSTALLATION
FLUSH POINT: SEE RAIN BIRD XFCV DETAILS
POTABLE: XFCV DRIPLINE
RAIN BIRD XF SERIES DRIPLINE (TYPICAL)
ON-SURFACE DRIPLINE:
PVC SCH 40 TEE OR EL (TYPICAL)
PVC SUPPLY HEADER
RAIN BIRD XFF-MA FITTING (TYPICAL)
BARB X MALE FITTING:
FLOW DEMAND)
ZONE VALVE KIT (SIZED TO MEET LATERAL
PVC DRIP MANIFOLD FROM RAIN BIRD CONTROL 1
2
3
4
5
6
7
DETERMINED BY PLANT AND SOIL TYPE. SEE NOTE 1.
X = DISTANCE BETWEEN ROWS OF DRIP LATERALS AS
2
4
3
5
FP
OF SLOPE
BOTTOM 1/3
OF SLOPE
TOP 2/3
7
6
5
1
4
5
3
2
1
N.T.S.
INSTALLED IN VALVE BOX
RAIN BIRD XCZ DRIP CONTROL ZONE KIT
:IRRIGATION CONTROL VALVE
RAIN BIRD MODEL: OPERIND
OPERATION INDICATOR
FINISH GRADE
2" - 3" DEPTH OF MULCH
PAVEMENT AND CURB
OF MANIFOLD PIPE SIZE
PVC SCH 40 SLEEVE PIPE SIZED TWICE THE SIZE
PVC SUPPLY HEADER
RAIN BIRD XFF-ELBOW
RAIN BIRD XFF-TEE OR
BARB X BARB INSERT TEE OR EL:
DETAILS FOR FLUSH POINT INSTALLATION
FLUSH POINT (TYPICAL) - SEE RAIN BIRD XFD
2"-4" FROM PERIMETER OF AREA
PERIMETER DRIPLINE PIPE TO BE INSTALLED
PERIMETER OF AREA
NON-POTABLE: XFS-CVP DRIPLINE
RAIN BIRD XFS-CV SERIES DRIPLINE (TYPICAL)
SUB-SURFACE/ON-SURFACE DRIPLINE:
FLOW DEMAND)
ZONE VALVE KIT (SIZED TO MEET LATERAL
PVC DRIP MANIFOLD FROM RAIN BIRD CONTROL
RAIN BIRD XFF-MA FITTING (TYPICAL)
BARB X MALE FITTING:
PVC SCH 40 TEE OR EL (TYPICAL)
PVC SUPPLY HEADER
2
6
7
1 3
9
8
9
10
7
RECOMMENDED THAT STAINLESS STEEL CLAMPS BE INSTALLED ON EACH FITTING.
6. WHEN USING 17MM INSERT FITTINGS WITH DESIGN PRESSURE OVER 50PSI, IT IS
TIE-DOWN STAKES ON EACH LEG OF THE CHANGE OF DIRECTION.
5. AT FITTINGS WHERE THERE IS A CHANGE OF DIRECTION SUCH AS TEES OR ELBOWS, USE
FEET IN CLAY.
4. PLACE TIE DOWN STAKES EVERY THREE FEET IN SAND, F0UR FEET IN LOAM, AND FIVE
SHOWN IN THE ACCOMPANYING TABLE.
3. LENGTH OF LONGEST DRIPLINE LATERAL SHOULD NOT EXCEED THE MAXIMUM SPACING
RAIN BIRD WEB SITE (WWW.RAINBIRD.COM) FOR SUGGESTED SPACING.
PLANT MATERIALS AND CHANGES IN ELEVATION. SEE INSTALLATION SPECIFICATIONS ON
2. DISTANCE BETWEEN LATERAL ROWS AND EMITTER SPACING TO BE BASED ON SOIL TYPE,
1. FOR ALL XFS-CV AND POLY CONNECTIONS INSTALL XFF AND/OR XFD FITTINGS
NOTES:
INSET A
1
2
INSET B
12
14
13
4
5
8
INSET A
INSET B
6
11
10 11 12
13
14
15
FP
2"-4"
FP
FP
1
42
2
13
14 1
OP
16
16
15
OP
15
OP15
IR-4
- OF -
1 3 4 DATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OFTEXAS NO:IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMIT PURPOSES.NOT FOR CONSTRUCTION3279ROBERT J. KINKEL6/14/18CITY OF DENTONPHASE TWOLANDFILL BUFFER LANDSCAPE DESIGNPHASE ONE
Date:Plotter:$ACCOUNT$May. 31, 2018 - 03:15:43 PMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfg02543N:\arc\Phase Two Landscape\Drawings\LA-MAYHILL RD- CV-P2- COVER.sht9999.9800 ft / in.Plot Scale:MicroStation V8 User:Date: May. 31, 2018 - 03:15:43 PM User:02543File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\arc\Phase Two Landscape\Drawings\LA-MAYHILL RD- CV-P2- COVER.shtProject:Mayhill SouthDefaultModel:DTN18117
CITY OF DENTON, TEXAS
LOCATION
PROJECT
COUNCIL MEMBER.........................SARA BAGHERI
COUNCIL MEMBER......................DALTON GREGORY
COUNCIL MEMBER..........................JOEY HAWKINS
COUNCIL MEMBER................KATHLEEN WAZNEY
COUNCIL MEMBER............................KEELY BRIGGS
COUNCIL MEMBER.............................KEVIN RODEN
MAYOR.....................................................CHRIS WATTS
8000'4000'0
SCALE IN FEET
JUNE 2018
TEXAS REGISTERED ENGINEERING FIRM F-2144
CITY MANAGER.................................TODD HILEMAN
CITY ENGINEER.................................FRANK G. PAYNE, P.E.
ISSUED FOR REVIEW
PHASE TWO
LANDFILL BUFFER LANDSCAPE DESIGN
NOT FOR CONSTRUCTION
DATE:
THIS DOCUMENT IS RELEASED FOR THE
PURPOSE OF INTERIM REVIEW UNDER THE
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION.
AUTHORITY OF MATTHEW L. MILANO
TEXAS NO: 3028 JUNE 2018
PLANTING LISTLA-5
PLANTING DETAILSLA-4
LANDSCAPE PLANTING PLANLA-3
LANDSCAPE PLANTING PLANLA-2
ORIENTATION PLANLA-1
SHEET INDEX
IR-1 IRRIGATION PLANS
IR-2 IRRIGATION PLANS
IR-3 IRRIGATION GENERAL NOTES +
DETAILS
IR-4 IRRIGATION DETAILS II
F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET
SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMELA-MAYHILL RD- CV-P2-KEYMAP.shtISSUES2220 San Jacinto Blvd., Suite 330MAY 2018CITY OF DENTONDate:Plotter:$ACCOUNT$May. 31, 2018 - 03:36:37 PMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfg02543N:\arc\Phase Two Landscape\Drawings\LA-MAYHILL RD- CV-P2-KEYMAP.sht159.9997 ' / in.Plot Scale:MicroStation V8 User:Date: May. 31, 2018 - 03:36:37 PM User:02543File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\arc\Phase Two Landscape\Drawings\LA-MAYHILL RD- CV-P2-KEYMAP.shtProject:Mayhill SouthDefaultModel:DTN18117PHASE TWOLANDFILLE BUFFER LANDSCAPE DESIGNGWSGWSGWS
PROPOSED S MAYHILL ROAD
LA-2 LA-2 LA-3 LA-3
NOT FOR CONSTRUCTIONDATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THENOT FOR REGULATORY APPROVAL,PERMITTING OR CONSTRUCTION.AUTHORITY OF MATTHEW L. MILANOTEXAS NO: 3028JUNE 2018HHEAFEAFMLMLANDSCAPE ARCHITECTUREORIENTATION PLANLA-1
160'80'0 40'
SCALE IN FEET
PHASE TWO
PHASE ONE
1 OF 5
F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET
SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMELA-MAYHILL RD- PL-P2-LANDSCAPE 01.shtISSUES2220 San Jacinto Blvd., Suite 330MAY 2018CITY OF DENTONDate:Plotter:$ACCOUNT$May. 31, 2018 - 04:25:57 PMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfg02543N:\arc\Phase Two Landscape\Drawings\LA-MAYHILL RD- PL-P2-LANDSCAPE 01.sht39.9999 ' / in.Plot Scale:MicroStation V8 User:Date: May. 31, 2018 - 04:25:57 PM User:02543File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\arc\Phase Two Landscape\Drawings\LA-MAYHILL RD- PL-P2-LANDSCAPE 01.shtProject:Mayhill SouthDefaultModel:DTN18117PHASE TWOLANDFILLE BUFFER LANDSCAPE DESIGNFL=599.42FL=598.9112"CMPgravelconcrete12"rcpFL=600.68Silted inMail BoxGWSFL=600.04FL=593.11FL=592.9430"RCPBUFFER LIMIT
56' LANDSCAPE
BUFFER LIMIT
56' LANDSCAPE
TYP.
40' O.C.
TYP.
20' O.C.
100'-0"
10' O.C. TYP.
TYP.
20' O.C.
TYP.
40' O.C.
10' O.C. TYP.
100'-0" SPECIES
TREE MLMEAFMLMLA-2 LANDSCAPE PLANTING PLANS LANDSCAPE ARCHITECT EAF2 OF 5
40'20'0 10'
SCALE IN FEET
LEGEND
UNDERSTORY TREE
CANOPY TREE DATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OFTEXAS NO:IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMIT PURPOSES.NOT FOR CONSTRUCTION3028JUNE 2018MATTHEW L. MILANO7. CONTRACTOR TO REPAIR ANY DAMAGED TURF GRASS RESULTING FROM INSTALLATION AT NO EXPANSE TO OWNER.
PROPOSED TREE LOCATIONS\ AS NOT TO IMPACT EXISTING TREES.
6. IF ANY PROPOSED TREE LOCATIONS CONFLICT WITH EXISTING TREE LOCATIONS, THE CONTRACTOR SHALL SHIFT THE
5. DO NOT REMOVE ANY EXISTING TREES.
4. REFER TO PLANT LIST SHEET LA-5 FOR PLANT QUANTITIES, SIZE, AND SPECIES INFORMATION.
3. REFER TO SHEET LA-4 FOR PLANTING DETAILS.
2. THE CONTRACTOR SHALL VERIFY ALL EASEMENT LINES AND VISIBILITY LINES IN THE FIELD PRIOR TO CONSTRUCTION.
1. ALL DIMENSIONS ARE TO CENTER OF TREE UNLESS NOTED OTHERWISE.
GENERAL NOTES MATCHLINE BMATCHLINE AMATCHLINE ATO REMAIN
EXISTING TREE
XX
CE CE CE CE
CE
CE CE CE CE CE CE CE CE
CE CE CE CE CE
CE
CE
CE
CE CE CECECECECECECECECECECECECECECE
CE
CE
CE CE CE CE CE CE CE CE CE CE CE CE CE CE
F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET
SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMELA-MAYHILL RD- PL-P2-LANDSCAPE 02.shtISSUES2220 San Jacinto Blvd., Suite 330MAY 2018CITY OF DENTONDate:Plotter:$ACCOUNT$May. 31, 2018 - 05:03:35 PMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfg02543N:\arc\Phase Two Landscape\Drawings\LA-MAYHILL RD- PL-P2-LANDSCAPE 02.sht39.9999 ' / in.Plot Scale:MicroStation V8 User:Date: May. 31, 2018 - 05:03:35 PM User:02543File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\arc\Phase Two Landscape\Drawings\LA-MAYHILL RD- PL-P2-LANDSCAPE 02.shtProject:Mayhill SouthDefaultModel:DTN18117PHASE TWOLANDFILLE BUFFER LANDSCAPE DESIGN24"RCPFL=600.04FL=600.17gravelGWSGWSconcreteBUFFER LIMIT
56' LANDSCAPE
BUFFER LIMIT
56' LANDSCAPE
TYP.
40' O.C.
TYP.
20' O.C.
10' O.C. TYP.
100'-0" 10' O.C. TYP.
TYP.
40' O.C.
TYP.
20' O.C.
100'-0"
SPECIES
TREE MLMEAFMLMLA-3 LANDSCAPE PLANTING PLANS LANDSCAPE ARCHITECT EAF2 OF 5
40'20'0 10'
SCALE IN FEET
LEGEND
UNDERSTORY TREE
CANOPY TREE DATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OFTEXAS NO:IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMIT PURPOSES.NOT FOR CONSTRUCTIONMATTHEW L. MILANO3028JUNE 2018MATCHLINE CMATCHLINE BMATCHLINE C7. CONTRACTOR TO REPAIR ANY DAMAGED TURF GRASS RESULTING FROM INSTALLATION AT NO EXPANSE TO OWNER.
PROPOSED TREE LOCATIONS\ AS NOT TO IMPACT EXISTING TREES.
6. IF ANY PROPOSED TREE LOCATIONS CONFLICT WITH EXISTING TREE LOCATIONS, THE CONTRACTOR SHALL SHIFT THE
5. DO NOT REMOVE ANY EXISTING TREES.
4. REFER TO PLANT LIST SHEET LA-4 FOR PLANT QUANTITIES, SIZE, AND SPECIES INFORMATION.
3. REFER TO SHEET LA-3 FOR PLANTING DETAILS.
2. THE CONTRACTOR SHALL VERIFY ALL EASEMENT LINES AND VISIBILITY LINES IN THE FIELD PRIOR TO CONSTRUCTION.
1. ALL DIMENSIONS ARE TO CENTER OF TREE UNLESS NOTED OTHERWISE.
GENERAL NOTES
TO REMAIN
EXISTING TREE
XX
CECECECECE
CE CE CE CE CE CE CE CE CE CE CE CE CE
CE CE CE CE
CE CE CE CE CE CE CE CE CE CE CE CE CE
F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET
SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMELA-MAYHILL RD- DT-P2-PLANT.shtISSUES2220 San Jacinto Blvd., Suite 330MAY 2018CITY OF DENTONDate:Plotter:$ACCOUNT$May. 31, 2018 - 03:30:11 PMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfg02543N:\arc\Phase Two Landscape\Drawings\LA-MAYHILL RD- DT-P2-PLANT.sht20.0000 ' / in.Plot Scale:MicroStation V8 User:Date: May. 31, 2018 - 03:30:11 PM User:02543File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\arc\Phase Two Landscape\Drawings\LA-MAYHILL RD- DT-P2-PLANT.shtProject:Mayhill SouthDefaultModel:DTN18117PHASE TWOLANDFILLE BUFFER LANDSCAPE DESIGNMLMEAFMLMLA-4LANDSCAPE ARCHITECT EAF4 OF 5DATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OFTEXAS NO:IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMIT PURPOSES.NOT FOR CONSTRUCTIONMATTHEW L. MILANO3028JUNE 2018PLANTING DETAILSPLANT CROWN AT GRADE
3" MULCH
TEMPORARY TREE WELL
FINISH GRADE
BACKFILL PLANTING PIT WITH SURFACE LAYER
PREPARED PLANTING SOIL MIX AS SPECIFIED
SCARIFY SURFACE PRIOR TO BACKFILLING
TO IMPROVE ROOT PENETRATION
TAMP TO PREVENT SETTLEMENT
TREE
CENTERED
IN
HOLE
NOTES:
1.TREE PLANTINGS IN THE HARDWOOD MULCH BEDS
TO RECEIVE 3" SHREDDED HARDWOOD MULCH,
UNIFORM COVERAGE. (SEE PLANS FOR TREE
LOCATIONS)
PLANT CROWN AT GRADE
3" MULCH
TEMPORARY TREE WELL
FINISH GRADE
BACKFILL PLANTING PIT WITH PREPARED
PLANTING SOIL MIX AS SPECIFIED
SCARIFY SURFACE PRIOR TO BACKFILLING
TO IMPROVE ROOT PENETRATION
TAMP TO PREVENT SETTLEMENT
PLANTING SOIL MIXTURE EQUALS
THREE (3) PARTS EXISTING SOIL
AND ON (1) PART FINELY
GROUND HARDWOOD MULCH,
THOROUGHLY MIXED
TREE
CENTERED
IN
HOLE
1/2 INCH DIA. X 36
INCH LONG NAIL
STAKES WITH ANGLED
TIP AT BOTTOM
MULCH TO BE PLACED 3"
AWAY FROM TREE TRUNK
PLANTING SOIL MIXTURE EQUALS
THREE (3) PARTS EXISTING SOIL
AND ON (1) PART FINELY
GROUND HARDWOOD MULCH,
THOROUGHLY MIXED
(3) T-POSTS WITH POST CAPS
ARBOR TIE TREE STAKING MATERIAL
(3) T-POSTS WITH POST CAPS
ARBOR TIE TREE STAKING MATERIAL
NOTES:
WITH THE CITY.
INSTALLATION SHALL BE COORDINATED
2. ALL TREE PRUNING AT THE TIME OF
SEASON.
REMOVED AFTER ONE FULL GROWING
ANCHORS AND ARBOR TIE TO BE
1. TEMPORARY TREE WELL, TREE
(3) T-POSTS WITH POST CAPS
ARBOR TIE TREE STAKING MATERIAL
PLANT CROWN AT GRADE
3" MULCH
TEMPORARY TREE WELL
FINISH GRADE
BACKFILL PLANTING PIT WITH PREPARED
PLANTING SOIL MIX AS SPECIFIED
SCARIFY SURFACE PRIOR TO BACKFILLING
TO IMPROVE ROOT PENETRATION
TAMP TO PREVENT SETTLEMENT
UNDISTURBED SUBGRADE
TREE
CENTERED
IN
HOLE
NOTES:
LOCATIONS)
COVERAGE. (SEE PLANS FOR HARDWOOD MULCH BED
RECEIVE 3" SHREDDED HARDWOOD MULCH, UNIFORM
1. TREE PLANTINGS IN THE HARDWOOD MULCH BEDS TO
1'-0"3" MIN.6" (TYP.)
6" (TYP.)3" MIN.1'-0"
6" (TYP.)3" MIN.1'-0"
ON ALL SIDES
1' MIN. CLEARANCE
2 TIMES CONTAINER SIZE
ON ALL SIDES
1' MIN. CLEARANCE
2 TIMES CONTAINER SIZE
1
NOT TO SCALELA-4
2
NOT TO SCALELA-4
CANOPY TREE PLANTING AND STAKING DETAIL
3
NOT TO SCALELA-4
UNDERSTORY EVERGREEN TREE PLANTING AND STAKING DETAIL
UNDERSTORY MULTI-TRUNK TREE PLANTING AND STAKING DETAIL
ON ALL SIDES
1' MIN. CLEARANCE
2 TIMES CONTAINER SIZE
T-POSTS
F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET
SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMELA-MAYHILL RD- DT-P2-PLANTLIST.shtISSUES2220 San Jacinto Blvd., Suite 330MAY 2018Date:Plotter:$ACCOUNT$May. 31, 2018 - 03:22:48 PMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfg02543N:\arc\Phase Two Landscape\Drawings\LA-MAYHILL RD- DT-P2-PLANTLIST.sht20.0000 ' / in.Plot Scale:MicroStation V8 User:Date: May. 31, 2018 - 03:22:48 PM User:02543File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\arc\Phase Two Landscape\Drawings\LA-MAYHILL RD- DT-P2-PLANTLIST.shtProject:Mayhill SouthDefaultModel:DTN18117 PLANT SCHEDULE
SYMBOL PERCENTAGE SIZE COMMON NAME BOTANICAL NAME CONDITION COMMENTS
CANOPY TREE
SG #65 CLASS MINIMUM SWEETGUM LIQUIDAMBER STYRACIFLUA CONTAINER FEET; FULL DENSE CANOPY; MATCH SELECTIONS FOR UNIFORM HEIGHT AND SPREAD
MINIMUM TRUNK DIAMETER 3 INCHES; MINIMUM SPREAD SIX FEET; MINIMUM HEIGHT TWELVE
RC #65 CLASS MINIMUM RED CEDAR JUNIPERUS VIRGINIANA CONTAINER FEET; FULL DENSE CANOPY; MATCH SELECTIONS FOR UNIFORM HEIGHT AND SPREAD
MINIMUM TRUNK DIAMETER 3 INCHES; MINIMUM SPREAD SIX FEET; MINIMUM HEIGHT TWELVE
AP #65 CLASS MINIMUM AFGHAN PINE PINUS ELDARICA CONTAINER FEET; FULL DENSE CANOPY; MATCH SELECTIONS FOR UNIFORM HEIGHT AND SPREAD
MINIMUM TRUNK DIAMETER 3 INCHES; MINIMUM SPREAD SIX FEET; MINIMUM HEIGHT TWELVE
BO #65 CLASS MINIMUM BURR OAK QUERCUS MACCROCARPA CONTAINER FEET; FULL DENSE CANOPY; MATCH SELECTIONS FOR UNIFORM HEIGHT AND SPREAD
MINIMUM TRUNK DIAMETER 3 INCHES; MINIMUM SPREAD SIX FEET; MINIMUM HEIGHT TWELVE
LE #65 CLASS MINIMUM LACEBARK ELM ULUMUS PARVIFOLIA CONTAINER FEET; FULL DENSE CANOPY; MATCH SELECTIONS FOR UNIFORM HEIGHT AND SPREAD
MINIMUM TRUNK DIAMETER 3 INCHES; MINIMUM SPREAD SIX FEET; MINIMUM HEIGHT TWELVE
PE #65 CLASS MINIMUM PECAN CARYA ILLINOISENSIS CONTAINER FEET; FULL DENSE CANOPY; MATCH SELECTIONS FOR UNIFORM HEIGHT AND SPREAD
MINIMUM TRUNK DIAMETER 3 INCHES; MINIMUM SPREAD SIX FEET; MINIMUM HEIGHT TWELVE
RB #65 CLASS MINIMUM RIVER BIRCH BETULA NIGRA CONTAINER FEET; FULL DENSE CANOPY; MATCH SELECTIONS FOR UNIFORM HEIGHT AND SPREAD
MINIMUM TRUNK DIAMETER 3 INCHES; MINIMUM SPREAD SIX FEET; MINIMUM HEIGHT TWELVE
UNDERSTORY TREE
AV #45 CLASS MINIMUM ARBOR VITAE THUGA ACCIDENTAILS CONTAINER SELECTIONS FOR UNIFORM HEIGHT AND SPREAD
MINIMUM SPREAD, FIVE FEET; MINIMUM HEIGHT TEN FEET; FULL DENSE CANOPY; MATCH
EP #45 CLASS MINIMUM EAST PALATKA HOLLY ILEX EAST PALATKA CONTAINER SELECTIONS FOR UNIFORM HEIGHT AND SPREAD
MINIMUM SPREAD, FIVE FEET; MINIMUM HEIGHT TEN FEET; FULL DENSE CANOPY; MATCH
MR #45 CLASS MINIMUM MEXICAN/ OKLAHOMA REDBUD
MEXICANA OR 'OKLAHOMA'
CERCIC CANADENSIS VAR.
CONTAINER SELECTIONS FOR UNIFORM HEIGHT AND SPREAD
MINIMUM SPREAD, FIVE FEET; MINIMUM HEIGHT TEN FEET; FULL DENSE CANOPY; MATCH
MP #45 CLASS MINIMUM MEXICAN PLUM PRUNUS MEXICANA CONTAINER SELECTIONS FOR UNIFORM HEIGHT AND SPREAD
MINIMUM SPREAD, FIVE FEET; MINIMUM HEIGHT TEN FEET; FULL DENSE CANOPY; MATCH
SH #45 CLASS MINIMUM STEVENS HOLLY ILEX NELLI R STEVENS CONTAINER SELECTIONS FOR UNIFORM HEIGHT AND SPREAD
MINIMUM SPREAD, FIVE FEET; MINIMUM HEIGHT TEN FEET; FULL DENSE CANOPY; MATCH
PH #45 CLASS MINIMUM POSSUMHAW HOLLY ILEX DECIDUA CONTAINER SELECTIONS FOR UNIFORM HEIGHT AND SPREAD
MINIMUM SPREAD, FIVE FEET; MINIMUM HEIGHT TEN FEET; FULL DENSE CANOPY; MATCH
INDICATED IN THE PLANT LIST MAY BE NECESSARY TO PROVIDE THE OTHER MINIMUM CRITERIA INDICATED.
CRITERIA REQUIRED. A CONTAINER SIZE LARGER THAN THE MINIMUM SIZE CONTAINER MINIMUM1). ALL SIZES SHOWN FOR ALL PLANTS (SUCH AS CALIPER, CONTAINER SIZE, SPREAD, HEIGHT, BRANCHING HEIGHT, ETC.) ARE THE
NOTE: MLMEAFMLMLA-5LANDSCAPE ARCHITECT EAF5 OF 5DATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OFTEXAS NO:IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMIT PURPOSES.NOT FOR CONSTRUCTIONMATTHEW L. MILANO3028JUNE 2018PLANTING LIST7
7
7
4
4
4
3
36
36
22
22
14
14 CITY OF DENTONPHASE TWOLANDFILLE BUFFER LANDSCAPE DESIGN
F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET
SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMEIR-MAYHILL RD- PL-P2-IRRIGATION 01.shtISSUESDTN103042220 San Jacinto Blvd., Suite 330AUG 2017Date:Plotter:$ACCOUNT$Jun. 14, 2018 - 10:57:58 AMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfgtmgN:\plbg\Phase 2\IR-MAYHILL RD- PL-P2-IRRIGATION 01.sht20.0000 ' / in.Plot Scale:MicroStation V8 User:Date: Jun. 14, 2018 - 10:57:58 AM User:tmg File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\plbg\Phase 2\IR-MAYHILL RD- PL-P2-IRRIGATION 01.shtProject:Mayhill SouthDefaultModel:Mail BoxGWSFL=599.42FL=598.9112"CMPgravelconcrete12"rcpFL=600.68Silted in10.75" GAS GATHERINGFL=600.04FL=593.11FL=592.9430"RCPRJKTMGTMGIR-1MATCHLINE AMATCHLINE BMATCHLINE A TMG- OF -
40'20'0 10'
SCALE IN FEET IRRIGATIONIRRIGATION PLANS2 TYP.
NOTE TO CONTRACTOR
PRIOR TO CONSTRUCTION
DEPARTMENT FOR APPROVAL
PLANS TO PERMIT
IRRIGATOR MUST SUBMIT
1
1
2 TYP.
NOTE BY SYMBOL " ":
GENERAL NOTES:
REFER TO IR-3 FOR GENERAL NOTES AND DETAILS.1.
PROVIDE TREE RING AT EACH NEW TREE AND NEW SHRUB CLUSTER.2.
AND ROADWAYS PER CITY OF DENTON STANDARDS.
MAIN. SLEEVE RIGID PVC BENEATH WALKS, DRIVES
DRIP LINE IRRIGATION SYSTEM WATER SUPPLY 1.
1
2 TYP.
STATION VALVE
2 TYP.
1
1 DATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OFTEXAS NO:IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMIT PURPOSES.NOT FOR CONSTRUCTION3279ROBERT J. KINKEL6/14/18CITY OF DENTONPHASE TWOLANDFILLE BUFFER LANDSCAPE DESIGN
F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET
SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMEIR-MAYHILL RD- PL-P2-IRRIGATION 02.shtISSUESDTN103042220 San Jacinto Blvd., Suite 330AUG 2017Date:Plotter:$ACCOUNT$Jun. 14, 2018 - 11:04:53 AMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfgtmgN:\plbg\Phase 2\IR-MAYHILL RD- PL-P2-IRRIGATION 02.sht20.0000 ' / in.Plot Scale:MicroStation V8 User:Date: Jun. 14, 2018 - 11:04:53 AM User:tmg File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\plbg\Phase 2\IR-MAYHILL RD- PL-P2-IRRIGATION 02.shtProject:Mayhill SouthDefaultModel:GWSGWS24"RCPFL=600.04FL=600.17gravel10.75" GAS GATHERING10.75" GAS GATHERINGconcreteRJKTMGTMGIR-2MATCHLINE CMATCHLINE C TMG- OF -
40'20'0 10'
SCALE IN FEETMATCHLINE BIRRIGATIONIRRIGATION PLANSNOTE TO CONTRACTOR
PRIOR TO CONSTRUCTION
DEPARTMENT FOR APPROVAL
PLANS TO PERMIT
IRRIGATOR MUST SUBMIT
2 TYP.
1
1
2 TYP.
2 TYP.
2 TYP.
NOTE BY SYMBOL " ":
GENERAL NOTES:
REFER TO IR-3 FOR GENERAL NOTES AND DETAILS.1.
PROVIDE TREE RING AT EACH NEW TREE AND NEW SHRUB CLUSTER.2.
AND ROADWAYS PER CITY OF DENTON STANDARDS.
MAIN. SLEEVE RIGID PVC BENEATH WALKS, DRIVES
DRIP LINE IRRIGATION SYSTEM WATER SUPPLY 1.DATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OFTEXAS NO:IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMIT PURPOSES.NOT FOR CONSTRUCTION3279ROBERT J. KINKEL6/14/18CITY OF DENTONPHASE TWOLANDFILLE BUFFER LANDSCAPE DESIGN
1
XFS-CV ON-SURFACE DRIPLINE INSERT ADAPTER
FOR 1" OR LARGER PVC
3
XFS-CV SUB-SURFACE/ON-SURFACE DRIPLINE
MULTIPLE TREE RING LAYOUT SIDE FED
2
XFS-CV SUB-SURFACE/ON-SURFACE DRIPLINE
QUICK LOOP LAYOUT-MEDIAN ISLAND DOWN SLOPE
2"-4"F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET
SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMEir-MAY-dt-detail01.dgnISSUESDTN103042220 San Jacinto Blvd., Suite 330AUG 2017Date:Plotter:$ACCOUNT$Jun. 13, 2018 - 02:12:20 PMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfgtmgN:\plbg\Phase 2\ir-MAY-dt-detail01.dgn0:1 ':" / in.Plot Scale:MicroStation V8 User:Date: Jun. 13, 2018 - 02:12:20 PM User:tmg File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\plbg\Phase 2\ir-MAY-dt-detail01.dgnProject:Mayhill SouthSheetModel:N.T.S.
4
3
2
1
1 2
OF DIRECTION.
OR ELBOWS, USE TIE-DOWN STAKES ON EACH LEG OF THE CHANGE
2. AT FITTINGS WHERE THERE IS A CHANGE OF DIRECTION SUCH AS TEES
LOAM, AND FIVE FEET IN CLAY.
1. PLACE TIE DOWN STAKES EVERY THREE FEET IN SAND, F0UR FEET IN
NOTES:
3 4
5
6
7
6
5
10
8
7
98
109
N.T.S.
FP FP FP
1
2
3
4
5
6
7
8
9
OP
1
2
3
4
5
6 7
89
10
11
10
11
NOTES:
1.FOR ALL XFS-CV AND POLY CONNECTIONS INSTALL XFF AND/OR XFD FITTINGS
2.SEE XFS-CV TREE RING DOUBLE OR TRIPLE FOR DETAIL OF EACH SET OF RINGS.
3.FOR TOTAL SYSTEM FLOW GREATER THAN 5 GPM USE PVC TO CONNECT TREE RINGS,
DOUBLE OR TRIPLE, AND SIZE PVC APPROPRIATELY.
N.T.S.
RAIN BIRD TDS-050 WITH BEND
TIE DOWN STAKE:
RAIN BIRD XFD-CROSS (TYPICAL)
BARB X BARB INSERT CROSS:
INSTALLED IN VALVE BOX
RAIN BIRD XCZ DRIP CONTROL ZONE KIT
:IRRIGATION CONTROL VALVE
FLOW)
PVC SUPPLY HEADER (SIZE BASED ON TOTAL
RAIN BIRD MODEL: OPERIND
OPERATION INDICATOR
RECOMMENDATION
XFS-CV SPACING PER RAIN BIRD
NON-POTABLE: XFS-CVP DRIPLINE
RAIN BIRD XFS-CV SERIES DRIPLINE (TYPICAL)
SUB-SURFACE/ON-SURFACE DRIPLINE:
TREE TRUNK
RAIN BIRD XF SERIES BLANK TUBING
SEE RAIN BIRD DETAIL "XFS-CV FLUSH POINT"
FLUSH POINT (TYPICAL)
SQUARE CONFIGURATION
MINIMUM 1" IN DIAMETER
PVC LATERAL PIPE
1"X1"X1/2" SST PVC TEE
TWIST LOCK FITTING : TLF-MPT6-0600
RAIN BIRD XFD SERIES BLANK TUBING
1/2" POLYETHYLENE TUBING:
FINISH GRADE
MULCH
BEND (TYPICAL)
TIE DOWN STAKE: RAIN BIRD TDS-050 WITH
INLINE DRIP EMITTER OUTLET
NON-POTABLE: XFS-CVP DRIPLINE
(TYPICAL)
RAIN BIRD XFS-CV SERIES DRIPLINE
ON-SURFACE DRIPLINE:
TWIST LOCK FITTING : TLF-TEE 0600
GENERAL NOTES:
RJKTMGTMGTMGIRRIGATION IR-3
WITH A SINGLE 1/2" FLUSHING HEADER. PROVIDE WITH END OF MAIN FLUSH POINT VALVE IN VALVE BOX.
FOR ALL SHRUB BEDS AND SMALL TURF AREAS, EXTEND DRIP LINE THROUGH THESE AREAS. SUPPLY SHRUB BEDS 10.
OR METER BOX.
TO PROVIDE THE MINIMUM PRESSURE AT THE FURTHEST STATION. INSTALL THE PRV IN A LARGE DIAMETER TURF
AND DELIVERING MINIMUM OF 50 PSIG DOWNSTREAM OF THE PRV. ADJUST THE DISCHARGE PRESSURES OF THE PRV
A PRESSURE REGULATOR (PRV) CAPABLE OF RECEIVING THE ACTUAL INLET PRESSURE OBTAINED FROM THE CITY
THE MINIMUM PRESSURE AT THE FURTHEST POINT IN THE DRIP SYSTEM OR RZWS IS 40 PSIG. THEREFORE PROVIDE
THE BASIS OF DESIGN IS THAT THE MINIMUM PRESSURE AVAILABLE AT EACH STATION VALVE EXCEEDS 50 PSIG. 9.
COMPLIANCE REPORTS TO THE OWNER IN THE O & M MANUALS.
ALL ELECTRICAL COMPONENTS OF THE SYSTEM. TEST THE SYSTEM TO INSURE COMPLIANCE AND PROVIDE
PROVIDE GROUNDING RODS OR SYSTEMS IN ACCORDANCE WITH THE 2016 NATIONAL ELECTRICAL CODE (NEC) FOR 8.
ON THE ACTUAL DESIGN PROVIDED BY THE LANDSCAPE IRRIGATION CONTRACTOR.
PIPE SIZES INDICATED ARE THE MINIMUM SIZES AND ARE FOR BIDDING PURPOSES ONLY. PROVIDE PIPE SIZES BASED 7.
AND OTHER OBSTRUCTIONS.
PIPE ROUTING SHOWN IS DIAGRAMMATIC. LOCATE PIPING, VALVES, AND FITTINGS TO AVOID EXISTING TREE ROOTS, 6.
OF CENTER FEED SYSTEMS. LOOP ENDS OF ALL DRIPLINE SYSTEMS.
DRIP SYSTEMS BASIS OF DESIGN SHALL BE RAINBIRD DRIPLINE. MAXIMIZE FLOW AND PRESSURE THROUGH THE USE 5.
BOXES SHALL BE RATED FOR H20 LOADS.
DIAMETER, OR OLDCASTLE MODEL 1324 POLYMER VALVE BOX WITH SINGLE PIECE STEEL COVER. ALL VAULTS AND
VALVE BOXES SHALL BE NO LESS STRINGENT THAN OLDCASTLE FIBRELYTE MODEL FL08 COMPOSITE 9 INCH
HEAVY DUTY, COMMERCIAL GRADE IN CONFORMANCE TO THE CFW STANDARDS, CONTROL VALVE AND SHUT OFF
METER VAULTS, BACKFLOW PREVENTER VAULTS, MANUAL SHUT OFF AND CONTROL VALVE BOXES SHALL BE 4.
LICENSED LANDSCAPE IRRIGATORS DRAWINGS, PERMITS, INSPECTIONS, ETC, SHALL BE INCLUDED IN THE BID.
DESIGNING THE SYSTEM AND COMPLY THEREIN. PROVISIONS FOR TAPPING FEES, PLANS EXAMINATIONS OF THE
COORDINATE METERING AND BACKFLOW PREVENTION REQUIREMENTS WITH THE CITY OF DENTON PRIOR TO 3.
TO THE PUBLISHED MANUFACTURERS STANDARDS.
EVERY VOID TO MAKE THE SLEEVE WATER-TIGHT. DRIP AND RZWS SHALL BE PROVIDED IN STRICT CONFORMANCE
PVC SLEEVES WITH 25 YEAR CLEAR SILICONE, A MINIMUM OF 4 INCHES INTO EACH SLEEVE END AND TO FILL
40 RIGID PVC PIPE , ONE INCH DIAMETER NOMINAL PIPE, OR AS REQUIRED BY THE CFW STANDARDS. SEAL ENDS OF
LARGER THAN THE PIPE OR TUBING. LOW VOLTAGE CONDUCTORS SHALL BE SLEEVED IN NO LESS THAN SCHEDULE
IN CONFORMANCE WITH THE CFW STANDARDS, NO LESS STRINGENT THAN SCHEDULE 80 RIGID PVC TWO SIZES
TURFAND SHRUBS. PROVIDE RIGID PVC SLEEVES BETWEEN DRIP STATIONS, BENEATH ROADWAYS, DRIVES AND WALKS
PROVIDE ROOT ZONE WATERING SYSTEMS (RZWS) FOR ALL TREES (2 EACH) AND DRIPLINE IRRIGATION FOR ALL 2.
IRRIGATION FOR ALL NEW LANDSCAPE PRODUCTS.
COORDINATE WITH THE LANDSCAPE DRAWINGS FOR EXACT LOCATION OF ALL COMPONENTS AND PROVIDE
WITH THE TXDOT STANDARDS AND REQUIREMENTS. RESIDENTIAL GRADE PRODUCTS ARE NOT PERMITTED.
OPERABLE COMMERCIAL GRADE LANDSCAPE IRRIGATION SYSTEM FOR ALL LANDSCAPE PRODUCTS IN CONFORMANCE
BASED DESIGN SPECIFICATION, WHERE CONFLICTS EXIST THE MORE STRINGENT SHALL APPLY. PROVIDE A COMPLETE
ARCHITECT/ENGINEER AS SHOP DRAWINGS. THE SPECIFICATIONS ARE AN INTEGRAL PART OF THIS PERFORMANCE
SYSTEM FUNCTIONAL, SUBMIT THE DRAWINGS TO DENTON FOR APPROVAL BEFORE SUBMITTING TO THE
VALVES, PIPE AND FITTINGS, RZWS AND DRIP SYSTEMS INCLUDING EVERY APPURTENANCE REQUIRED TO MAKE THE
CONTRACTOR SHALL PROVIDE A COMPLETE DESIGN, INCLUDING EACH AND EVERY COMPONENT OF THE CONTROLS,
OF THE SYSTEM INCLUDING BASIC ROUTING, TYPE OF SYSTEM REQUIRED AND SPECIFICATIONS OF COMPONENTS. THE
THE SYSTEMS INDICATED ON THESE DRAWINGS ARE A PERFORMANCE BASED DESIGN, PROVIDING THE PARAMETERS 1.GENERAL NOTES AND DETAILS- OF -DATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OFTEXAS NO:IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMIT PURPOSES.NOT FOR CONSTRUCTION3279ROBERT J. KINKEL6/14/18CITY OF DENTONPHASE TWOLANDFILLE BUFFER LANDSCAPE DESIGN
5
XFCV ON-SURFACE DRIPLINE
SLOPED LAYOUT
6
XFS-CV SUB-SURFACE/ON-SURFACE DRIPLINE
TYPICAL ISLAND LAYOUT W/ PVC HEADERS
12"1.33
8".53
1
2
4
3
5
6 8 97
BLACK WIRE
x
x+
x
x+
SLOPE SPACING
BOTTOM 1/3 OF
NORMAL SPACING
TOP 2/3 OF SLOPE
xxxxxxxx x
x+
x
(Feet)
XFCV Dripline Maximum Lateral Lengths
Inlet Pressure psi
12" Spacing 18" Spacing
Nominal Flow (gph)Nominal Flow (gph)
0.6 0.9 0.6 0.9
20 192 136 254 215
30 289 205 402 337
40 350 248 498 416
50 397 281 573 477
60 436 309 637 529
x
x+
BURIAL DEPTH
DRIP MANIFOLD
(Feet)
XFS-CV Dripline Maximum Lateral Lengths
Inlet Pressure psi
12" Spacing 18" Spacing
Nominal Flow (gph)Nominal Flow (gph)
0.6 0.9 0.6 0.9
20 192 136 254 215
30 289 205 402 337
40 350 248 498 416
50 397 281 573 477
60 436 309 637 529 F&N JOB NO.DATEDESIGNEDDRAWNREVISEDCHECKEDDATEBY1NO.VERIFY SCALE0SHEET
SEQ.this sheet, adjust scale.drawing. If not one inch onBar is one inch on originalFILE NAMEir-MAY-dt-detail02.dgnISSUESDTN103042220 San Jacinto Blvd., Suite 330AUG 2017Date:Plotter:$ACCOUNT$Jun. 13, 2018 - 02:15:39 PMJ:\Plotdrv_V8.11\PDF_File\PDF-Mono.pltcfgtmgN:\plbg\Phase 2\ir-MAY-dt-detail02.dgn0:1 ':" / in.Plot Scale:MicroStation V8 User:Date: Jun. 13, 2018 - 02:15:39 PM User:tmg File:$ACCOUNT$Fort WorthOffice:Fort WorthOffice:N:\plbg\Phase 2\ir-MAY-dt-detail02.dgnProject:Mayhill SouthSheetModel: RJKTMGTMGTMGIRRIGATION 1 LEIT CONTROLLER MODEL LEIT 4000
6 FINISH GRADE
1
2
3
4
6
5
MODEL 30-405
2 HIGH SECURITY STAINLESS STEEL DISC-LOCK
1
7
NOT TO SCALE
CONCRETE
BASE USING 90 Lb. (40 kg) BAG OF
5 12" X 18" (30 x 45 cm) CONCRETE
CONTROL VALVES.
7 DIRECT BURIAL CONTROL WIRES TO
MOUNTING MODEL ENCL 4000
AND INTERNAL CLAMP TO SECURE COLUMN
WITH LIGHT ACCESS THROUGH GRID ON TOP
3 HEAVY-DUTY STAINLESS STEEL ENCLOSURE
FOR LEIT 4000 AND 4000E
4 GALVANIZED STEEL MOUNTING COLUMN
a. MODEL MCOL 4000 32" (81 cm) SHORT
b. MODEL MCOL 4000L 48" (124 cm) LONG
6 to 10 FEET HIGH.
5 1" or 1.5" GALVANIZED PIPE
VALVE BOX.
9 6" ROUND
FROM SENSOR.
13 NORMALLY CLOSED WIRE
RAIN SENSOR.
1 "MINI CLIK"
WITH HOLE FOR WIRES.
1.5" CAP PART No. 23-053
1" CAP PART No. 23-001 or
2 DIG PLASTIC PIPE CAP
FROM SENSOR.
14 COMMON WIRE
11 TO CONTROLLER OR VALVE.
8" DEEP MINIMUM.
6 12" X 12" CONCRETE BASE
AND NUT.
WITH WASHER, LOCK WASHER
4 (2) #8-32 MACHINE SCREWS
FOR SENSOR BRACKET.
3 DRILL TWO 3/16 HOLES IN PIPE
SKIT
8 FINISH GRADE.
16 GRAVEL.
CONNECTORS.
12 (4) DRY SPLICE
2
LEGEND
7 1" or 1.5" PIPE ELBOW.
15 1"or 1.5" NIPPLE.
USE WITH EACH SENSOR.
PART NO. 8821-4
10 SKIT ADAPTER
16
15
14 13 12 11
10
NOT TO SCALE
WHITE WIREBLACK WIRE
RED WIRE
9
6
8
7
5
4
11111111111
3
2
2
5
6
8
10
11
VALVE BOX WITH COVER
12" SIZE
FINISH GRADE TOP
DIG LEIT 3/4" REMOTE
MODEL P52-075 (30 PSI)
PVC LATERAL LINE
PEA GRAVEL SUMP
MINIMUM 3"
BRICK SUPPORT AT EACH
CORNER
7
10
11
3 4
9
12 SCH 40 TEE
PVC SCH 40 90 DEGREE
ELL
13
12
1
13
23-004 1" F X 3/4" M
MAIN SUPPLY LINE
SWIVEL FITTING DIG MODEL
CONTROL WIRE TO OTHER VALVE
WIRE CONNECTORS
CONTROL VALVE ASSEMBLY
3/4" FEMALE NPT
COUPLING x SLIP
NOT TO SCALE
4
2 31
MINIMUM2"6
8
5
4
DRY SPLICE CONNECTORS.
4 DIG VALVE MODEL
3/4" 160HE - 075
1" 160HE - 100
7
9
10
11
12
13
10
11
12
13 12 OR 14 GAUGE WIRE.
3
REMOTE CONTROL VALVE FOR LEIT CONTROLLER
1
2
3
5
6
7
8
9
SIZE.
VALVE BOX WITH COVER 18"
FINISH GRADE TOP.
SWIVEL FITTING DIG MODEL
3/4" 23-004, 1" 23-003.
PVC SCH 40 MALE ADAPTER.
PVC LATERAL LINE.
BRICK SUPPORT AT EACH CORNER.
PEA GRAVEL SUMP - MINIMUM 3".
BACK-UP NPT PVC BALL VALVE.
PVC SCH 40 90 DEGREE ELL.
SCH 40 TEE.
LEGEND
160HE-075 3/4" AND 160HE-100 1"
NOT TO SCALE
RAIN SENSOR ASSEMBLY (COLUMN MOUNTED)
USING SKIT 8821-4 RAIN SENSOR
4000
STAINLESS STEEL ENCLOSURE MODEL ENCL
ACCESSIBLE STAINLESS STEEL ENCLOSURE
LEIT 4000 AND 4000E WITH LIGHT DRIP ZONE ASSEMBLY FOR LEIT SYSTEM
3/4" PRESET 30 PSI P52-075
DETAILS IIINSTALLED ON EACH FITTING.
50PSI, IT IS RECOMMENDED THAT STAINLESS STEEL CLAMPS BE
WHEN USING 17MM INSERT FITTINGS WITH DESIGN PRESSURE OVER 4.
THAT A NEW DRIPLINE ZONE BE CREATED.
3. WHEN ELEVATION CHANGE EXCEEDS 10 FEET IT IS RECOMMENDED
MAXIMUM LENGTH SHOWN IN THE ACCOMPANYING TABLE.
2. LENGTH OF LONGEST DRIPLINE LATERAL SHOULD NOT EXCEED THE
SPACING.
SEE RAIN BIRD XFD DRIPLINE INSTALLATION GUIDE FOR SUGGESTED
OF SLOPE TO BE SPACED GREATER THAN OPTIMAL ROW DISTANCE.
ELEVATION. DISTANCE BETWEEN LATERAL ROWS FOR BOTTOM 1/3
BASED ON SOIL TYPE, PLANT MATERIALS AND CHANGES IN
1. DISTANCE BETWEEN LATERAL ROWS AND EMITTER SPACING TO BE
NOTES:
PVC FLUSH HEADER
FOR FLUSH POINT INSTALLATION
FLUSH POINT: SEE RAIN BIRD XFCV DETAILS
POTABLE: XFCV DRIPLINE
RAIN BIRD XF SERIES DRIPLINE (TYPICAL)
ON-SURFACE DRIPLINE:
PVC SCH 40 TEE OR EL (TYPICAL)
PVC SUPPLY HEADER
RAIN BIRD XFF-MA FITTING (TYPICAL)
BARB X MALE FITTING:
FLOW DEMAND)
ZONE VALVE KIT (SIZED TO MEET LATERAL
PVC DRIP MANIFOLD FROM RAIN BIRD CONTROL 1
2
3
4
5
6
7
DETERMINED BY PLANT AND SOIL TYPE. SEE NOTE 1.
X = DISTANCE BETWEEN ROWS OF DRIP LATERALS AS
2
4
3
5
FP
OF SLOPE
BOTTOM 1/3
OF SLOPE
TOP 2/3
7
6
5
1
4
5
3
2
1
N.T.S.
INSTALLED IN VALVE BOX
RAIN BIRD XCZ DRIP CONTROL ZONE KIT
:IRRIGATION CONTROL VALVE
RAIN BIRD MODEL: OPERIND
OPERATION INDICATOR
FINISH GRADE
2" - 3" DEPTH OF MULCH
PAVEMENT AND CURB
OF MANIFOLD PIPE SIZE
PVC SCH 40 SLEEVE PIPE SIZED TWICE THE SIZE
PVC SUPPLY HEADER
RAIN BIRD XFF-ELBOW
RAIN BIRD XFF-TEE OR
BARB X BARB INSERT TEE OR EL:
DETAILS FOR FLUSH POINT INSTALLATION
FLUSH POINT (TYPICAL) - SEE RAIN BIRD XFD
2"-4" FROM PERIMETER OF AREA
PERIMETER DRIPLINE PIPE TO BE INSTALLED
PERIMETER OF AREA
NON-POTABLE: XFS-CVP DRIPLINE
RAIN BIRD XFS-CV SERIES DRIPLINE (TYPICAL)
SUB-SURFACE/ON-SURFACE DRIPLINE:
FLOW DEMAND)
ZONE VALVE KIT (SIZED TO MEET LATERAL
PVC DRIP MANIFOLD FROM RAIN BIRD CONTROL
RAIN BIRD XFF-MA FITTING (TYPICAL)
BARB X MALE FITTING:
PVC SCH 40 TEE OR EL (TYPICAL)
PVC SUPPLY HEADER
2
6
7
1 3
9
8
9
10
7
RECOMMENDED THAT STAINLESS STEEL CLAMPS BE INSTALLED ON EACH FITTING.
6. WHEN USING 17MM INSERT FITTINGS WITH DESIGN PRESSURE OVER 50PSI, IT IS
TIE-DOWN STAKES ON EACH LEG OF THE CHANGE OF DIRECTION.
5. AT FITTINGS WHERE THERE IS A CHANGE OF DIRECTION SUCH AS TEES OR ELBOWS, USE
FEET IN CLAY.
4. PLACE TIE DOWN STAKES EVERY THREE FEET IN SAND, F0UR FEET IN LOAM, AND FIVE
SHOWN IN THE ACCOMPANYING TABLE.
3. LENGTH OF LONGEST DRIPLINE LATERAL SHOULD NOT EXCEED THE MAXIMUM SPACING
RAIN BIRD WEB SITE (WWW.RAINBIRD.COM) FOR SUGGESTED SPACING.
PLANT MATERIALS AND CHANGES IN ELEVATION. SEE INSTALLATION SPECIFICATIONS ON
2. DISTANCE BETWEEN LATERAL ROWS AND EMITTER SPACING TO BE BASED ON SOIL TYPE,
1. FOR ALL XFS-CV AND POLY CONNECTIONS INSTALL XFF AND/OR XFD FITTINGS
NOTES:
INSET A
1
2
INSET B
12
14
13
4
5
8
INSET A
INSET B
6
11
10 11 12
13
14
15
FP
2"-4"
FP
FP
142
2
13
14 1
OP
16
16
15
OP
15
OP15
IR-4
- OF -DATE:THIS DOCUMENT IS RELEASED FOR THEPURPOSE OF INTERIM REVIEW UNDER THEAUTHORITY OFTEXAS NO:IT IS NOT TO BE USED FOR CONSTRUCTION,BIDDING OR PERMIT PURPOSES.NOT FOR CONSTRUCTION3279ROBERT J. KINKEL6/14/18CITY OF DENTONPHASE TWOLANDFILLE BUFFER LANDSCAPE DESIGN