Loading...
2018.02.22_COD_Inspection i Gas Well Inspection Type 2017 Annual �oF I n s p e ct i o n s Inspection Cycle 2nd Half _ DENTOR 24hr Phone 888-225-8141 Well Operator Sage Inspection Date 10-30-17 Record Close Date 12-19-17 Active Padsite Name 28 Mitchell-Baldinger Pad Jurisdiction CoD Re-Inspection Date 12-19-17 Site Address 2672 Thomas J Egan Rd. Padsite Type Multi Well Rt 02 2nd Follow-up Inspection Ordinance Reg 2002-040 Inspected by Rod Weatherby Inspection Status Closed Plat/Site Permit No Plan No Lease Name .RRC Id Aoi No. Spud Date Imoact 1108-0693 GWP02-0001 MITCHELL-BALDINGER 3H 264324 12134107 10/26/2011 3 Urban 1108-0707 GWP02-0001 MITCHELL-BALDINGER 4H 264852 12134108 11/12/2011 3 Urban 1107-0356 GWP02-0001 MITCHELL,GERALD 2 189372 12131261 3/3/2002 3 Urban INSPECTION CHECK LIST Signs General Location I Operator Name x Good Need Resolved Fencing x Good Need Resolved Site Address x Good Need Resolved Entry Gate Locked Good Need x Resolved Well Name x Good Need Resolved Site Surface x Good Need Resolved 24hr. Phone No x Good Need Resolved Stains Good Need x Resolved RRC&Api No x Good Need Resolved Trash/Debris x Good Need Resolved No Smoking x Good Need Resolved Weeds/Brush Good Need x Resolved Reflective/Lighting x Good Need Resolved Oders/Fumes/Dust x Good Need Resolved Site Lighting x Good Need Resolved Facility Equipment Landscaping x Good Need Resolved Wellhead Paint x Good Need Resolved Wellhead Leaks Good Need x Resolved Miscellaneous Tank Battery Paint x Good Need Resolved Electric Lines Safe x Good Need Resolved Tank Battery Leaks x Good Need Resolved Pipeline Markers x Good Need Resolved Equip Height x Good Need Resolved No Wells Approved Db Level @Inspection Layout Per Site Plan x Good Need Resolved Erosion Control Referred Fire Dept. Fire Lane Access Referred Tank Integrity Referred Foam Lines Referred Auto Safety Valve Referred Containment Integrity Referred Lightning Arresting Referred Tank Level Activated Referred Drip Pots @ Disconnects Referred Pit Fencing Referred Accessible ESD Referred Storage Tank Labels Referred Pit Liner Integrity Referred Inspection Comments Upon entry, Gate found open, upon exit gate closed and locked,#3H wing valve needs repair-stem packing leaking, remove dead vegetation from inside WH fence, Chem Tank labels need replaced, Containment liner needs repaired, Stains around sump needs remediation, Recommend: Preventative maintenance to Tank 24846-manway showing heavy corrosion. On 12/19/17, RW conducted a follow-up inspection of the well site.All items requiring further attention from the Operator were —resolved.