Loading...
2018.02.22_COD_Inspection i Gas Well Inspection Type 2017 Annual � L��OF I n s p e ct i o n s Inspection Cycle 2nd Half _ DENTOR 24hr Phone 855-820-6008 Well Operator Eagleridge Inspection Date 10-11-17 Record Close Date 12-13-17 Active Padsite Name 75 Mayday-Lattimore Pad Jurisdiction CoD Re-Inspection Date 12-13-17 Site Address 1522 S I-35 Padsite Type Multi Well Rt 25 2nd Follow-up Inspection Ordinance Reg 2010-196 Inspected by Rod Weatherby Inspection Status Closed Plat/Site Permit No Plan No Lease Name .RRC Id Aoi No. Spud Date Imoact 1109-0143 GWP10-0015 MAYDAY-LATTI MORE GAS UNIT I 264186 12134126 5/4/2011 2 High 1201-0467 GWP10-0015 Mayday-Lattimore Gas Unit 2H 267776 12134173 3/29/2012 2 High 1304-0001 GWP10-0015 Mayday-Mason Unit 3H 273100 12134365 4/27/2013 2 High 1304-0004 GWP10-0015 Mayday-Mason Unit 4H 274427 12134366 5/15/2013 2 High 1308-0648 GWP10-0015 Mayday-UNT 5H 275569 12134414 8/29/2013 2 High INSPECTION CHECK LIST Signs General Location I Operator Name x Good Need Resolved Fencing x Good Need Resolved Site Address x Good Need Resolved Entry Gate Locked x Good Need Resolved Well Name x Good Need Resolved Site Surface x Good Need Resolved 24hr. Phone No x Good Need Resolved Stains x Good Need Resolved RRC&Api No x Good Need Resolved Trash/Debris x Good Need Resolved No Smoking x Good Need Resolved Weeds/Brush x Good Need Resolved Reflective/Lighting x Good Need Resolved Oders/Fumes/Dust x Good Need Resolved Site Lighting x Good Need Resolved Facility Equipment Landscaping x Good Need Resolved Wellhead Paint x Good Need Resolved Wellhead Leaks x Good Need Resolved Miscellaneous Tank Battery Paint x Good Need Resolved Electric Lines Safe x Good Need Resolved Tank Battery Leaks Good Need x Resolved Pipeline Markers x Good Need Resolved Equip Height x Good Need Resolved Layout Per Site Plan x Good Need Resolved No Wells Approved Db Level @Inspection Erosion Control Referred Fire Dept. Fire Lane Access Referred Tank Integrity Referred Foam Lines Referred Auto Safety Valve Referred Containment Integrity Referred Lightning Arresting Referred Tank Level Activated Referred Drip Pots @ Disconnects Referred Pit Fencing Referred Accessible ESD Referred Storage Tank Labels Referred Pit Liner Integrity Referred Inspection Comments Cap open Rat hole, Pry at compressor leaking, HPG 30 Kimray Regulator to compressor Ieaking,DV Controller hung needs repair -operator made repair during inspection, Stairway needs modification to meet Osha standards, Thief hatch needs repair, Unt#5 tank showing signs of heavy corrosion. 12/13/17 GWI Follow-up-Operator addressed issues i_ Gas Well Inspection Type 2017 Annual 1 I n s p e ct i o n s Inspection C cle CIT - J y 2nd Half _ DENTU J