Loading...
2018.02.22_COD_Inspection i Gas Well Inspection Type 2017 Annual � L��OF I n s p e ct i o n s Inspection Cycle 2nd Half _ DENTOR 24hr Phone 817-588-0372 Well Operator Enervest Inspection Date 12-4-17 Record Close Date 12-28-17 Active Padsite Name 146 ROBSON RANCH 500 Jurisdiction CoD Re-Inspection Date 12-28-17 Site Address 7593 Florence Rd. Padsite Type Multi Well Rt 20 2nd Follow-up Inspection Ordinance Reg 2005-223 Inspected by Rod Weatherby Inspection Status Closed Plat/Site Permit No Plan No Lease Name .RRC Id Aoi No. Spud Date Imoact 1109-0239 GWP08-0031 ROBSON RANCH 501H 259581 12133860 3/11/2010 3 Urban 1109-0235 GWP08-0031 ROBSON RANCH 502H 258247 12133862 3/28/2010 3 Urban 1109-0237 GWP08-0031 ROBSON RANCH 503H 258402 12133864 1/17/2010 3 Urban 1109-0238 GWP08-0031 ROBSON RANCH 504H 258532 12133863 2/19/2010 3 Urban 1109-0236 GWP08-0031 ROBSON RANCH 505H 258255 12133910 3/30/2010 3 Urban INSPECTION CHECK LIST Signs General Location I Operator Name x Good Need Resolved Fencing x Good Need Resolved Site Address x Good Need Resolved Entry Gate Locked x Good Need Resolved Well Name x Good Need Resolved Site Surface x Good Need Resolved 24hr. Phone No x Good Need Resolved Stains x Good Need Resolved RRC&Api No x Good Need Resolved Trash/Debris x Good Need Resolved No Smoking x Good Need Resolved Weeds/Brush Good Need x Resolved Reflective/Lighting x Good Need Resolved Oders/Fumes/Dust x Good Need Resolved Site Lighting x Good Need Resolved Facility Equipment Landscaping x Good Need Resolved Wellhead Paint x Good Need Resolved Wellhead Leaks Good Need x Resolved Miscellaneous Tank Battery Paint x Good Need Resolved Electric Lines Safe x Good Need Resolved Tank Battery Leaks Good Need x Resolved Pipeline Markers x Good Need Resolved Equip Height x Good Need Resolved Layout per Site Plan x Good Need Resolved No Wells Approved Db Level @Inspection Erosion Control Referred Fire Dept. Fire Lane Access Referred Tank Integrity Referred Foam Lines Referred Auto Safety Valve Referred Containment Integrity Referred Lightning Arresting Referred Tank Level Activated Referred Drip Pots @ Disconnects Referred Pit Fencing Referred Accessible ESD Referred Storage Tank Labels Referred Pit Liner Integrity Referred Inspection Comments Reg @ 505 WH needs repair, Fisher D4 controll valve(down stream of dump line)venting needs repair,weed control needed along east wall. Recommend DV Controller maint, Recommend replacing 505H RRC ID No at entrance sign-operator showing 685508 drilling permit correct number is 258255. On 12/28/17,RW conducted a follow-up inspection of the well site.All items i Gas Well Inspection Type 2017 Annual COF I n s p e ct i o n s Inspection Cycle 2nd Half _ DENTOR —requiring further attention from the Operator were resolved.