Loading...
2018.02.22_COD_Inspection i Gas Well Inspection Type 2017 Annual �oF I n s p e ct i o n s Inspection Cycle 2nd Half _ DENTOR 24hr Phone 817-588-0372 Well Operator Enervest Inspection Date 12-4-17 Record Close Date 12-22-17 Active Padsite Name 148 ROBSON RANCH 200 Jurisdiction CoD Re-Inspection Date 12-22-17 Site Address (12003)Gallery Drive Padsite Type Multi Well Rt 19 2nd Follow-up Inspection Ordinance Reg 2005-223 Inspected by Rod Weatherby Inspection Status Closed Plat/Site Permit No Plan No Lease Name .RRC Id Aoi No. Spud Date Imoact 1109-0226 GWP08-0027 ROBSON RANCH 201 H 252536 12133591 3/26/2009 1 High 1109-0224 GWP08-0027 ROBSON RANCH 2O2H 252534 12133600 3/9/2009 1 High 1109-0228 GWP08-0027 ROBSON RANCH 2O3H 253040 12133598 2/24/2008 1 High 1109-0227 GWP08-0027 ROBSON RANCH 2O4H 253033 12133599 2/10/2009 1 High INSPECTION CHECK LIST Signs General Location Operator Name x Good Need Resolved Fencing x Good Need Resolved Site Address x Good Need Resolved Entry Gate Locked x Good Need Resolved Well Name x Good Need Resolved Site Surface x Good Need Resolved 24hr. Phone No x Good Need Resolved Stains x Good Need Resolved RRC&Api No x Good Need Resolved Trash/Debris x Good Need Resolved No Smoking x Good Need Resolved Weeds/Brush Good Need x Resolved Reflective/Lighting x Good Need Resolved Oders/Fumes/Dust x Good Need Resolved Site Lighting x Good Need Resolved I Facility Equipment I Landscaping x Good Need Resolved Wellhead Paint x Good Need Resolved Wellhead Leaks x Good Need Resolved Miscellaneous Tank Battery Paint x Good Need Resolved Electric Lines Safe Good Need Resolved Tank Battery Leaks Good Need x Resolved Pipeline Markers Good Need Resolved Equip Height x Good Need Resolved Layout per Site Plan x Good Need Resolved No Wells Approved Db Level @Inspection Erosion Control Referred Fire Dept. I Fire Lane Access Referred Tank Integrity Referred Foam Lines Referred Auto Safety Valve Referred Containment Integrity Referred Lightning Arresting Referred Tank Level Activated Referred Drip Pots @ Disconnects Referred Pit Fencing Referred Accessible ESD Referred Storage Tank Labels Referred Pit Liner Integrity Referred Inspection Comments I Weed controll needed, Fisher D4 control valve venting needs repair, Reg @ sep(marked Norm)venting needs repair, _Recommend DV Controller maint. On 12/22/17, RW conducted a follow-up inspection of the well site.All items requiring further attention from the Operator were resolved. i_ Gas Well Inspection Type 2017 Annual 1 I n s p e ct i o n s Inspection C cle CIT - J y 2nd Half _ DENTU J