Loading...
2018.02.22_COD_Inspection i_ Gas Well Inspection Type 2017 Annual 1 I n s p e ct i o n s Inspection C cle C1T -- JJ y 2nd Half _ DENTOM 24hr Phone 888-791-9095 Well Operator Hillwood Inspection Date 12-6-17 Record Close Date 1-4-18 Active Padsite Name 152 HUNTER RANCH J Pad Jurisdiction CoD Re-Inspection Date 1-4-18 Site Address 7696 Robson Rd. Padsite Type Multi Well Rt 02 2nd Follow-up Inspection Ordinance Reg 2005-223 Inspected by Rod Weatherby Inspection Status Closed Plat/Site Permit No Plan No Lease Name .RRC Id Aoi No. Spud Date Imoact 1108-0654 GWP08-0028 HUNTER RANCH J 1 H 254528 12133619 5/11/2009 4 Rural 1108-0653 GWP08-0028 HUNTER RANCH J2H 254160 12133708 5/31/2009 4 Rural 1109-0271 GWP08-0028 W.J. LAKES UNIT J1 H 253739 12133620 3/30/2009 4 Rural 1109-0272 GWP08-0028 W.J. LAKES UNIT J2H 253741 12133613 12/30/2008 4 Rural INSPECTION CHECK LIST Signs General Location Operator Name x Good Need Resolved Fencing x Good Need Resolved Site Address x Good Need Resolved Entry Gate Locked x Good Need Resolved Well Name x Good Need Resolved Site Surface x Good Need Resolved 24hr. Phone No x Good Need Resolved Stains x Good Need Resolved RRC&Api No x Good Need Resolved Trash/Debris x Good Need Resolved No Smoking x Good Need Resolved Weeds/Brush x Good Need Resolved Reflective/Lighting x Good Need Resolved Oders/Fumes/Dust x Good Need Resolved Site Lighting x Good Need Resolved I Facility Equipment I Landscaping x Good Need Resolved Wellhead Paint x Good Need Resolved Wellhead Leaks Good Need x Resolved Miscellaneous Tank Battery Paint x Good Need Resolved Electric Lines Safe x Good Need Resolved Tank Battery Leaks Good Need x Resolved Pipeline Markers x Good Need Resolved Equip Height x Good Need Resolved Layout per Site Plan x Good Need Resolved No Wells Approved Db Level @Inspection Erosion Control Referred Fire Dept. I Fire Lane Access Referred Tank Integrity Referred Foam Lines Referred Auto Safety Valve Referred Containment Integrity Referred Lightning Arresting Referred Tank Level Activated Referred Drip Pots @ Disconnects Referred Pit Fencing Referred Accessible ESD Referred Storage Tank Labels Referred Pit Liner Integrity Referred Inspection Comments I _WJL L1 H Master Valve leaking immediate attention is required to address this issue. Issue resolved 12/12/17 Containment liner needs repair,WJL J2 Dump Valve venting needs repair,WJL J1 Dump Valve leaking @ Stem packing needs repair, HIR J1 Kimray SMT Venting recommend repair. 1/4/18 RW follow-up-Containment Liner scheduled to be repaired in —early spring. Containment integrity to 18" all other issues resolved i_ Gas Well Inspection Type 2017 Annual 1 I n s p e ct i o n s Inspection C cle CIT - J y 2nd Half _ DENTU J