Loading...
2018.06.07_COD_FollowUp i Gas Well Inspection Type 2018 Annual COF I n s p e ct i o n s Inspection Cycle 1st Half _ DENTOR 24hr Phone 888-225-8141 Well Operator Sage Inspection Date 4-20-18 Record Active Padsite Name 21 LONG TERM Pad Close Date 6-7-18 Jurisdiction CoD Re-Inspection Date 6-7-18 Site Address 1896 Nail Rd Padsite Type Multi Well Rt 09 2nd Follow-up Inspection Ordinance Reg 2004-059 Rod Weatherby Inspected by y Inspection Status Closed Plat/Site Permit No Plan No Lease Name .RRC Id Aai No. Spud Date Imoact 1109-0139 AGWP04 LONG TERM 1 207197 12132392 11/20/2004 Moderate 1405-0183 GWSP13 LONG TERM AGF(SA)1H 275134 12134453 6/7/2014 Moderate 1405-0184 GWSP13 LONG TERM AGF(SA)2H 275956 12134454 6/5/2014 Moderate 1405-0185 GWSP13 LONG TERM AGF(SA)3H 275141 12134455 5/31/2014 Moderate 1406-0609 GWSP13 LONG TERM BALDINGER(SA)1H 275150 12134456 7/15/2014 Moderate 1406-0617 GWSP13 LONG TERM BALDINGER(SA)2H 275140 12134457 7/17/2014 Moderate 1407-0039 GWSP13 LONG TERM BALDINGER(SA)3H 276745 12134458 7/16/2014 Moderate 1407-0398 GWSP13 LONG TERM RENDA(SA)1 H 276903 12134473 9/2/2014 Moderate 1407-0402 GWSP13 LONG TERM RENDA(SA)2H 277062 12134469 9/4/2014 Moderate 1407-0411 GWSP13 LONG TERM RENDA(SA)3H 277063 12134470 9/5/2014 Moderate 1407-0412 GWSP13 LONG TERM RENDA(SA)4H 277640 12134471 9/6/2014 Moderate 1407-0413 GWSP13 LONG TERM RENDA(SA)5H 276967 12134472 9/7/2014 Moderate INSPECTION CHECK LIST Signs General Location I Operator Name x Good Need Resolved Fencing x Good Need Resolved Site Address x Good Need Resolved Entry Gate Locked x Good Need Resolved Well Name x Good Need Resolved Site Surface x Good Need Resolved 24hr. Phone No x Good Need Resolved Stains x Good Need Resolved RRC&Api No x Good Need Resolved Trash/Debris x Good Need Resolved No Smoking x Good Need Resolved Weeds/Brush x Good Need Resolved Reflective/Lighting x Good Need Resolved Oders/Fumes/Dust x Good Need Resolved Site Lighting x Good Need Resolved Facility Equipment Landscaping x Good Need Resolved Wellhead Paint x Good Need Resolved Wellhead Leaks Good Need x Resolved Miscellaneous Tank Battery Paint x Good Need Resolved Electric Lines Safe x Good Need Resolved Tank Battery Leaks Good Need x Resolved Pipeline Markers x Good Need Resolved Equip Height x Good Need Resolved No Wells Approved Db Level @Inspection Layout per Site Plan x Good Need Resolved Erosion Control Referred _ 0 Gas Well Inspection Type 2018 Annual �oFilim I n s p e ct i o n s Inspection Cycle 1st Half _ DENTON Fire Dept. I Fire Lane Access Referred Tank Integrity Referred Foam Lines Referred Auto Safety Valve Referred Containment Integrity Referred Lightning Arresting Referred Tank Level Activated Referred Drip Pots @ Disconnects Referred Pit Fencing Referred Accessible ESD Referred Storage Tank Labels Referred Pit Liner Integrity Referred Inspection Comments LTR2H at well head Kimray Actuator venting needs repair, TB-Tank R3H equalizer line dripping,Tank R5h drain leaking,Tank 131 H load line leaking. Note: Due to wind speed and wind direction, unable to conduct accurate leak detection,will perform another leak detection at a later date inclusive with the first inspection not a re-inspection). On 6/7/18 RW conducted inspection —for emissions and follow up on previous items. At WH-2 regulators and 1 Hammer union found venting below compliance level= —recommended repair, At TB found 4 DV controllers venting, repairs made during inspection. All issues resolved