2018.07.03_COD_FollowUp Gas Well Inspection Type 2018 Annual �oF Inspections Inspection Cycle 1st Half _ DENTOR 24hr Phone 855-820-6008 Well Operator Eagleridge Inspection Date 5-21-18 Record Close Date 6-28-18 Active Padsite Name 16 PARKS UNIT Pad Jurisdiction CoD Re-Inspection Date 6-28-18 Site Address 2400 W.Payne Dr.(Windsor) Padsite Type Multi Well Rt 28 2nd Follow-up Inspection Ordinance Reg 2005-223 Rod Weatherby Inspected by y Inspection Status Closed Plat/Site Permit No Plan No Lease Name .RRC Id Aoi No. Spud Date Imoact 1106-0505 GWP06-0023 PARKS UNIT I 236682 12133026 2/26/2007 High 1106-0504 GWP06-0023 PARKS UNIT 2H 235551 12133062 4/1/2007 High INSPECTION CHECK LIST Signs General Location I Operator Name x Good Need Resolved Fencing x Good Need Resolved Site Address x Good Need Resolved Entry Gate Locked x Good Need Resolved Well Name x Good Need Resolved Site Surface x Good Need Resolved 24hr. Phone No x Good Need Resolved Stains x Good Need Resolved RRC&Api No x Good Need Resolved Trash/Debris x Good Need Resolved No Smoking x Good Need Resolved Weeds/Brush Good Need x Resolved Reflective/Lighting x Good Need Resolved Oders/Fumes/Dust x Good Need Resolved Site Lighting x Good Need Resolved Facility Equipment Landscaping x Good Need Resolved Wellhead Paint x Good Need Resolved Miscellaneous Wellhead Leaks x Good Need Resolved Tank Battery Paint x Good Need Resolved Electric Lines Safe x Good Need Resolved Tank Battery Leaks Good Need x Resolved Pipeline Markers x Good Need Resolved Equip Height x Good Need Resolved Layout per Site Plan x Good Need Resolved No Wells Approved Db Level @Inspection Erosion Control Referred I Fire Dept. Fire Lane Access Referred Tank Integrity Referred Foam Lines Referred Auto Safety Valve Referred Containment Integrity Referred Lightning Arresting Referred Tank Level Activated Referred Drip Pots @ Disconnects Referred Pit Fencing Referred Accessible ESD Referred Storage Tank Labels Referred Pit Liner Integrity Referred Inspection Comments Recomment adding RRC#to entry sign and TB signs, Weed control touch up needed, Compressor 2nd stage DV controler needs repair (red flag), TB Separoator Dv Controler needs repair(red flag). On 6/21/18,RW conducted a follow-up inspection of the well site.All items —requiring further attention from the Operator were not yet resolved.The Operator was contacted and/or another follow-up inspection will be- -conducted. On 6/28/18,RW conducted a follow-up inspection of the well site.Operator resolved all items requiring further attention.