Loading...
2018.07.03_COD_FollowUp Gas Well Inspection Type 2018 Annual �oF I n s p e ct i o n s Inspection Cycle 1st Half _ DENTOR 24hr Phone 855-820-6008 Well Operator Eagleridge Inspection Date 5-15-18 Record Active Padsite Name 44 Paddock Pad Close Date 6-29-18 Jurisdiction CoD Re-Inspection Date 6-29-18 Site Address 4393 Jim Christal Rd. Padsite Type Multi Well Rt 04 2nd Follow-up Inspection Ordinance Reg 2005-223 Rod Weatherby Inspected by y Inspection Status Closed Plat/Site Permit No Plan No Lease Name .RRC Id Aoi No. Spud Date Imoact 1109-0153 GWP06-0011 PADDOCK 1 H 252531 12133388 5/7/2008 Low 1109-0156 GWP02-0006 PADDOCK 2H 252754 12133441 6/6/2008 Low 1109-0155 GWP02-0006 PADDOCK 3H 252533 12133443 7/18/2008 Low INSPECTION CHECK LIST Signs General Location I Operator Name x Good Need Resolved Fencing x Good Need Resolved Site Address x Good Need Resolved Entry Gate Locked Good Need x Resolved Well Name x Good Need Resolved Site Surface x Good Need Resolved 24hr. Phone No x Good Need Resolved Stains x Good Need Resolved RRC&Api No x Good Need Resolved Trash/Debris x Good Need Resolved No Smoking x Good Need Resolved Weeds/Brush x Good Need Resolved Reflective/Lighting x Good Need Resolved Oders/Fumes/Dust x Good Need Resolved Site Lighting x Good Need Resolved Facility Equipment Landscaping x Good Need Resolved Wellhead Paint x Good Need Resolved Miscellaneous Wellhead Leaks x Good Need Resolved Tank Battery Paint x Good Need Resolved Electric Lines Safe x Good Need Resolved Tank Battery Leaks Good Need x Resolved Pipeline Markers x Good Need Resolved Equip Height x Good Need Resolved No Wells Approved Db Level @Inspection Layout per Site Plan x Good Need Resolved Erosion Control Referred Fire Dept. Fire Lane Access Referred Tank Integrity Referred Foam Lines Referred Auto Safety Valve Referred Containment Integrity Referred Lightning Arresting Referred Tank Level Activated Referred Drip Pots @ Disconnects Referred Pit Fencing Referred Accessible ESD Referred Storage Tank Labels Referred Pit Liner Integrity Referred Inspection Comments I No lock @ Entry Gate, Operator replaced lock during inspection, Tank 1 seep leaking needs repair, Recommend DV Controller maint, dump line piping showing heavy corrosion recommend replaciement. On 6/18/18,RW conducted a follow-up inspection of the well site.All —items requiring further attention from the Operator were not yet resolved.The Operator was contacted and/or another follow-up inspection will be —conducted.. On 6/29/18,RW conducted a follow-up inspection of the well site.Operator resolved all items requiring further attention.