2018.07.20_COD_FollowUp i Gas Well Inspection Type 2018 Annual �oF I n s p e ct i o n s Inspection Cycle 1st Half _ DENTOR 24hr Phone 855-820-6008 Well Operator Eagleridge Inspection Date 5-18-18 Record Active Close Date 7-16-18 Padsite Name 65 Rayzor West 12 Pad Jurisdiction CoD Re-Inspection Date 7-16-18 Site Address 2952 Airport Rd Padsite Type Multi Well Rt 24 2nd Follow-up Inspection Ordinance Reg 2013-014 Rod Weatherby Inspected by y Inspection Status Closed Plat/Site Permit No Plan No Lease Name .RRC Id Aoi No. Spud Date Imoact 1307-0048 Agwp10 Rayzor West Gas Unit 12H#1 276949 12134382 7/4/2013 Moderate 1307-0064 Agwp10 Rayzor West Gas Unit 12H#2 275601 12134383 7/7/2013 Moderate 1307-0070 Agwp10 Rayzor West Gas Unit 12H#3 274416 12134384 10/11/2013 Moderate 1307-0071 Agwp10 Rayzor West Gas Unit 12H#4 274980 12134385 11/9/2013 Moderate 1108-0598 GWP06 Rayzor West Gas Unit 12H#5D 255643 12132952 9/11/2006 Moderate INSPECTION CHECK LIST Signs General Location I Operator Name x Good Need Resolved Fencing x Good Need Resolved Site Address x Good Need Resolved Entry Gate Locked x Good Need Resolved Well Name x Good Need Resolved Site Surface x Good Need Resolved 24hr. Phone No x Good Need Resolved Stains x Good Need Resolved RRC&Api No x Good Need Resolved Trash/Debris x Good Need Resolved No Smoking x Good Need Resolved Weeds/Brush Good Need x Resolved Reflective/Lighting x Good Need Resolved Oders/Fumes/Dust x Good Need Resolved Site Lighting x Good Need Resolved Facility Equipment Landscaping x Good Need Resolved Wellhead Paint x Good Need Resolved Wellhead Leaks x Good Need Resolved Miscellaneous Tank Battery Paint x Good Need Resolved Electric Lines Safe x Good Need Resolved Tank Battery Leaks Good Need x Resolved Pipeline Markers x Good Need Resolved Equip Height x Good Need Resolved Layout per Site Plan x Good Need Resolved No Wells Approved Db Level @Inspection Erosion Control Referred Fire Dept. I Fire Lane Access Referred Tank Integrity Referred Foam Lines Referred Auto Safety Valve Referred Containment Integrity Referred Lightning Arresting Referred Tank Level Activated Referred Drip Pots @ Disconnects Referred Pit Fencing Referred Accessible ESD Referred Storage Tank Labels Referred Pit Liner Integrity Referred Inspection Comments I Brush needs to be removed, DV Controller needs repair(red flag),Tank 4 has seep leak needs repair, thief hatches need maint. On 6/19/18,RW conducted a follow-up inspection of the well site.All items requiring further attention from the Operator were not yet resolved.The —Operator was contacted and/or another follow-up inspection will be conducted.On 7/16//18,RW conducted a follow-up inspection of the well site. _Operator resolved all items noted on inspection comments. During follow up inspection RW observed what appeared to be a saltwater discharge __ Gas Well Inspection Type 2018 Annual 1 I n s p e ct i o n s Inspection C cle CIT - J y 1st Half _ DENTO J and traced it back to the containment wall and found a hole in the liner. Operator made repairs during inspection and will evaluate for remediation