2019.01.03_COD_FollowUp i Gas Well Inspection Type 2018 Annual �oF I n s p e ct i o n s Inspection Cycle 2nd Half _ DENTOR 24hr Phone 888-225-8141 Well Operator Sage Inspection Date 10-30-18 Record Close Date 11-30-18 Active Padsite Name 28 Mitchell-Baldinger Pad Jurisdiction CoD Re-Inspection Date 11-30-18 Site Address 2672 Thomas J Egan Rd. Padsite Type Multi Well Rt 02 2nd Follow-up Inspection Ordinance Reg 2002-040 Rod Weatherby Inspected by y Inspection Status Closed Plat/Site Permit No Plan No Lease Name .RRC Id Aoi No. Spud Date Imoact 1108-0693 GWP02-0001 MITCHELL-BALDINGER 3H 264324 12134107 10/26/2011 Moderate 1108-0707 GWP02-0001 MITCHELL-BALDINGER 4H 264852 12134108 11/12/2011 Moderate 1107-0356 GWP02-0001 MITCHELL,GERALD 2 189372 12131261 3/3/2002 Moderate INSPECTION CHECK LIST Signs/Labels General Location I Operator Name • Good Need Resolved Fencing • Good Need Resolved Site Address • Good Need Resolved Entry Gate Locked • Good Need Resolved Well Name • Good Need Resolved Site Surface • Good Need Resolved 24hr.Phone No • Good Need Resolved Stains • Good Need Resolved RRC&Api No • Good Need Resolved Trash/Debris • Good Need Resolved No Smoking • Good Need Resolved Weeds/Brush • Good Need Resolved Reflective/Lighting • Good Need Resolved Oders/Fumes/Dust • Good Need Resolved Wellhead Sign • Good Need Resolved Site Lighting • Good Need Resolved Tank Battery Sign • Good Need Resolved Landscaping • Good Need Resolved Storage Tank Labels Good Need • Resolved Erosion Control • Good Need Resolved Facility Equipment I Miscellaneous I Wellhead Paint Good Need • Resolved Electric Lines Safe • Good Need Resolved Wellhead Leaks Good Need • Resolved Pipeline Markers • Good Need Resolved Tank Battery Paint • Good Need Resolved Layout Per Site Plan • Good Need Resolved Tank Battery Leaks Good Need • Resolved Tank Integrity • Good Need Resolved No Wells Approved Db Level @ Inspection Containment Integrity • Good Need Resolved Fire Dept. Drip Pots@ Load • Good Need Resolved Lightning Arresting • Good Need Resolved Fire Lane Access Referred Tank Level Activated Referred Equip Height • Good Need Resolved Foam Lines Referred Pit Fencing Referred Accessible ESD Referred Auto Safety Valve Referred Inspection Comments Recommend replacing Well Head sign stickers due to fading. Bare pipe at WH need paint, Casing valves venting at stem packing needs maintenance(red flag). Chem Tanks need Hazcom Labels. At middle sep. Kimray SMA valve venting at Actuator(red flag). On —11/30/18,RW conducted a follow-up inspection of the well site.Operator addressed all items requiring further attention.