Loading...
2019.01.03_COD_FollowUp i Gas Well Inspection Type 2018 Annual COF I n s p e ct i o n s Inspection Cycle 2nd Half _ DENTOR 24hr Phone 855-820-6008 Well Operator Eagleridge Inspection Date 11-15-18 Record Close Date 12-17-18 Active Padsite Name 63 Rayzor West 3 Pad Jurisdiction CoD Re-Inspection Date 12-17-18 Site Address 852 S Western Blvd Padsite Type Multi Well Rt 01 2nd Follow-up Inspection Ordinance Reg 2013-014 Rod Weatherby Inspected by y Inspection Status Closed Plat/Site Permit No Plan No Lease Name .RRC Id Aoi No. Spud Date Imoact 1304-0679 GWP08-0029 Rayzor West Gas Unit 5H#7 273577 12134363 5/17/2013 Low 1304-0680 GWP08-0029 Rayzor West Gas Unit 5H#8 272689 12134362 7/1/2013 Low INSPECTION CHECK LIST Signs/Labels General Location Operator Name • Good Need Resolved Fencing • Good Need Resolved Site Address • Good Need Resolved Entry Gate Locked • Good Need Resolved Well Name • Good Need Resolved Site Surface • Good Need Resolved 24hr.Phone No • Good Need Resolved Stains • Good Need Resolved RRC&Api No • Good Need Resolved Trash/Debris • Good Need Resolved No Smoking • Good Need Resolved Weeds/Brush • Good Need Resolved Reflective/Lighting • Good Need Resolved Oders/Fumes/Dust • Good Need Resolved Wellhead Sign • Good Need Resolved Site Lighting • Good Need Resolved Tank Battery Sign Good Need • Resolved Landscaping • Good Need Resolved Storage Tank Labels • Good Need Resolved Erosion Control • Good Need Resolved Facility Equipment Miscellaneous Wellhead Paint • Good Need Resolved Electric Lines Safe • Good Need Resolved Wellhead Leaks • Good Need Resolved Pipeline Markers • Good Need Resolved Tank Battery Paint • Good Need Resolved Layout per Site Plan • Good Need Resolved Tank Battery Leaks Good Need • Resolved Tank Integrity Good Need • Resolved No Wells Approved Db Level @ Inspection Containment Integrity • Good Need Resolved Fire Dept. Drip Pots@ Load • Good Need Resolved Lightning Arresting • Good Need Resolved Fire Lane Access Referred Tank Level Activated Referred Equip Height • Good Need Resolved Foam Lines Referred Pit Fencing Referred Accessible ESD Referred Auto Safety Valve Referred Inspection Comments Tank Battery signs required by RRC non-compliant. Recommend replacing Chem Tank Hazcom Labels. DV Controller found not working properly, repaired during inspection. Tank 2 found seep leaking Needs repair. On 12/17/18,RW conducted a follow-up inspection —of the well site.Operator resolved all items requiring further attention.