2019.01.03_COD_FollowUp i Gas Well Inspection Type 2018 Annual � L��OF I n s p e ct i o n s Inspection Cycle 2nd Half _ DENTOR 24hr Phone 432-570-1911 Well Operator Endeavor Inspection Date 10-16-18 Record Active Padsite Name 137 WSW Pad Close Date 11-28-18 Jurisdiction CoD Re-Inspection Date 11-28-18 Site Address 3602 Tuscan Hills Circle Padsite Type Multi Well Rt 01 2nd Follow-up Inspection Ordinance Reg 2004-059 Rod Weatherby Inspected by y Inspection Status Closed Plat/Site Permit No Plan No Lease Name _ RRC Id Aoi No. Spud Date Imoact 1109-0298 GWP04-0019 DENTON STATE SCHOOL 1H 247096 12132413 1/4/2005 Moderate 1109-0308 GWP04-0019 WESTMINSTER 1H 250079 12132422 4/6/2006 Moderate 1109-0310 GWP04-0019 WINDJAMMER 1H 2O8172 12132417 10/14/2004 Moderate INSPECTION CHECK LIST Signs/Labels General Location I Operator Name • Good Need Resolved Fencing • Good Need Resolved Site Address • Good Need Resolved Entry Gate Locked • Good Need Resolved Well Name • Good Need Resolved Site Surface • Good Need Resolved 24hr.Phone No • Good Need Resolved Stains • Good Need Resolved RRC&Api No • Good Need Resolved Trash/Debris • Good Need Resolved No Smoking • Good Need Resolved Weeds/Brush Good Need • Resolved Reflective/Lighting • Good Need Resolved Oders/Fumes/Dust • Good Need Resolved Wellhead Sign Good Need • Resolved Site Lighting • Good Need Resolved Tank Battery Sign Good Need • Resolved Landscaping • Good Need Resolved Storage Tank Labels • Good Need Resolved Erosion Control • Good Need Resolved Facility Equipment I Miscellaneous I Wellhead Paint • Good Need Resolved Electric Lines Safe • Good Need Resolved Wellhead Leaks • Good Need Resolved Pipeline Markers • Good Need Resolved Tank Battery Paint • Good Need Resolved Layout per Site Plan • Good Need Resolved Tank Battery Leaks Good Need • Resolved Tank Integrity • Good Need Resolved No Wells Approved Db Level @ Inspection Containment Integrity • Good Need Resolved Fire Dept. Drip Pots@ Load Good Need • Resolved Lightning Arresting • Good Need Resolved Fire Lane Access Referred Tank Level Activated Referred Equip Height • Good Need Resolved Foam Lines Referred Pit Fencing Referred Accessible ESD Referred Auto Safety Valve Referred Inspection Comments Wellhead signs need to be posted, Well signs at Tank Battery needed. Middle Sep DV Controller venting needs repair. Drip Pot needed at TB Load line that's outside containment. Weed control needed. on 11/28/18,RW conducted a follow-up inspection of the well site. —Operator resolved all items requiring further attention.