2019.03.06_COD_FollowUp Gas Well Inspection Type 2018 Annual �oF Inspections Inspection Cycle 2nd Half _ DENTOR 24hr Phone 855-820-6008 Well Operator Eagleridge Inspection Date 12-3-18 Record Active Close Date Padsite Name 81 CHAMBERLAIN-ELDER Jurisdiction CoD Re-Inspection Date 1-7-19 Site Address 3900 Roselawn Padsite Type Multi Well Rt 36 2nd Follow-up Inspection 3-4-19 Ordinance Reg 2014-084 Rod Weatherby Inspected by y Inspection Status Closed Plat/Site Permit No Plan No Lease Name .RRC Id Aoi No. Spud Date Imoact 1106-0500 GWP02-0024 CHAMBERLAIN-ELDER UNIT 1 206947 12132411 09/14/2004 High 1106-0501 GWP02-0024 CHAMBERLAIN-ELDER UNIT 2H 238803 12133178 3/8/2008 High 1106-0502 GWP02-0024 CHAMBERLAIN-ELDER UNIT 3H 239252 12133263 1/25/2008 High INSPECTION CHECK LIST Signs/Labels General Location I Operator Name • Good Need Resolved Fencing • Good Need Resolved Site Address • Good Need Resolved Entry Gate Locked • Good Need Resolved Well Name • Good Need Resolved Site Surface • Good Need Resolved 24hr.Phone No • Good Need Resolved Stains • Good Need Resolved RRC&Api No Good Need • Resolved Trash/Debris • Good Need Resolved No Smoking • Good Need Resolved Weeds/Brush • Good Need Resolved Reflective/Lighting • Good Need Resolved Oders/Fumes/Dust • Good Need Resolved Wellhead Sign • Good Need Resolved Site Lighting • Good Need Resolved Tank Battery Sign Good Need • Resolved Landscaping • Good Need Resolved Storage Tank Labels • Good Need Resolved Erosion Control • Good Need Resolved Facility Equipment I Miscellaneous I Wellhead Paint • Good Need Resolved Electric Lines Safe • Good Need Resolved Wellhead Leaks Good Need • Resolved Pipeline Markers • Good Need Resolved Tank Battery Paint • Good Need Resolved Layout per Site Plan • Good Need Resolved Tank Battery Leaks Good Need • Resolved Tank Integrity Good Need • Resolved No Wells Approved Db Level @ Inspection Containment Integrity Good • Need Resolved Fire Dept. Drip Pots@ Load • Good Need Resolved Lightning Arresting • Good Need Resolved Fire Lane Access Referred Tank Level Activated Referred Equip Height • Good Need Resolved Foam Lines Referred Pit Fencing Referred Accessible ESD Referred Auto Safety Valve Referred Inspection Comments Signs need correct RRC ID. #1 WH ss fitting loose and venting 10% lel. Tank Battery signs need RRC ID#. Tank out of service not disconnected from In-service tanks and found venting thru hole. DV Controllers found venting at 10% lel. Containment Liner needs repair. On 1/7/19 RW conducted a re-inspection,WH Leaks were repaired DV controllers were repaired. Hole in tank repaired, Signs —and Containment liner issues not addressed. On 3/4/19, RW conducted a re-inspection. Upon arriving on location a leak from the _containment liner was discovered. The liquid was checked with a salinity analyizer and found to be greater than allowable. Operator advised that the spill would be reported to the RRC and remediation would begin. Issues with the signs were resolved