2019.05.24_COD_FollowUp Gas Well Inspection Type 2019 Annual - 1 Inspections ct i o n s Inspection C cle cOF -- JJ y 1st Half _ DENTOM 24hr Phone 888-791-9095 Well Operator Hillwood Inspection Date 4-19-19 Record Close Date 5-23-19 Active Padsite Name 152 HUNTER RANCH J Pad Jurisdiction CoD Re-Inspection Date 5-23-19 Site Address 7696 Robson Rd. Padsite Type Multi Well Rt 02 2nd Follow-up Inspection Ordinance Reg 2005-223 Rod Weatherby Inspected by y Inspection Status Closed Plat/Site Permit No Plan No Lease Name .RRC Id Avi No. Spud Date Impact 1108-0654 GWP08-0028 HUNTER RANCH J 1 H 254528 12133619 5/11/2009 Low 1108-0653 GWP08-0028 HUNTER RANCH J2H 254160 12133708 5/31/2009 Low 1109-0271 GWP08-0028 W.J. LAKES UNIT J1 H 253739 12133620 3/30/2009 Low 1109-0272 GWP08-0028 W.J. LAKES UNIT J2H 253741 12133613 12/30/2008 Low INSPECTION CHECK LIST Signs/Labels General Location I Operator Name • Good Need Resolved Fencing • Good Need Resolved Site Address • Good Need Resolved Entry Gate Locked • Good Need Resolved Well Name • Good Need Resolved Site Surface • Good Need Resolved 24hr.Phone No • Good Need Resolved Stains • Good Need Resolved RRC&Api No • Good Need Resolved Trash/Debris • Good Need Resolved No Smoking • Good Need Resolved Weeds/Brush Good Need • Resolved Reflective/Lighting • Good Need Resolved Oders/Fumes/Dust • Good Need Resolved Wellhead Sign • Good Need Resolved Site Lighting • Good Need Resolved Tank Battery • Good Need Resolved Landscaping • Good Need Resolved Storage Tank Labels • Good Need Resolved Erosion Control • Good Need Resolved Facility Equipment I Miscellaneous Wellhead Paint • Good Need Resolved Electric Lines Safe • Good Need Resolved Wellhead Leaks • Good Need Resolved Pipeline Markers • Good Need Resolved Tank Battery Paint • Good Need Resolved Layout Per Site Plan • Good Need Resolved Tank Battery Leaks Good Need • Resolved Tank Integrity • Good Need Resolved No Wells Approved Db Level @ Inspection Containment Integrity • Good Need Resolved Fire Dept. Drip Pots@ Load • Good Need Resolved Lightning Arresting • Good Need Resolved Fire Lane Access Referred Tank Level Activated Referred Equip Height • Good Need Resolved Foam Lines Referred Pit Fencing Referred Accessible ESD Referred Auto Safety Valve Referred Inspection Comments I DV Controller venting at J2 sep. Operator made repairs. Weed control needed. Recommend applying new Operator Name Stickers to Well signs. On 5/23/19, RW conducted a follow-up inspection. Operator addressed issues Gas Well Inspection Type 2019 Annual - 1 Inspections Inspection C cle cOF — Jy 1st Half _ DENTU J