Loading...
2019.11.08_COD_FollowUp Gas Well Inspection Type 2019 Annual C0F Inspections Inspection Cycle 2nd Half _ DENTOR 24hr Phone 888-225-8141 Well Operator Sage Inspection Date 10-15-19 Record Close Date 11-7-19 Active Padsite Name 28 Mitchell-Baldinger Pad Jurisdiction CoD Re-Inspection Date 11-7-19 Site Address 2672 Thomas J Egan Rd. Padsite Type Multi Well Rt 02 2nd Follow-up Inspection Ordinance Reg 2002-040 Rod Weatherby Inspected by Y Inspection Status Closed Plat/Site Permit No Plan No Lease Name .RRC Id Avi No. Spud Date Impact 1107-0356 GWP02-0001 MITCHELL,GERALD 2 189372 12131261 3/3/2002 Moderate 1108-0693 GWP02-0001 MITCHELL-BALDINGER 3H 264324 12134107 10/26/2011 Moderate 1108-0707 GWP02-0001 MITCHELL-BALDINGER 4H 264852 12134108 11/12/2011 Moderate INSPECTION CHECK LIST Signs/Labels General Location I Operator Name • Good Need Resolved Fencing • Good Need Resolved Site Address • Good Need Resolved Entry Gate Locked • Good Need Resolved Well Name • Good Need Resolved Site Surface • Good Need Resolved 24hr.Phone No • Good Need Resolved Stains Good Need • Resolved RRC&Api No • Good Need Resolved Trash/Debris • Good Need Resolved No Smoking • Good Need Resolved Weeds/Brush • Good Need Resolved Reflective/Lighting • Good Need Resolved Oders/Fumes/Dust • Good Need Resolved Wellhead Sign • Good Need Resolved Site Lighting • Good Need Resolved Tank Battery • Good Need Resolved Landscaping • Good Need Resolved Storage Tank Labels • Good Need Resolved Erosion Control • Good Need Resolved Facility Equipment I Miscellaneous I Wellhead Paint • Good Need Resolved Electric Lines Safe • Good Need Resolved Wellhead Leaks Good Need • Resolved Pipeline Markers • Good Need Resolved Tank Battery Paint • Good Need Resolved Layout Per Site Plan • Good Need Resolved Tank Battery Leaks Good Need • Resolved Tank Integrity • Good Need Resolved No Wells Approved Db Level @ Inspection Containment Integrity • Good Need Resolved Fire Dept. Drip Pots@ Load • Good Need Resolved Lightning Arresting • Good Need Resolved Fire Lane Access Referred Tank Level Activated Referred Equip Height • Good Need Resolved Foam Lines Referred Pit Fencing Referred Accessible ESD Referred Auto Safety Valve Referred Inspection Comments I Wellhead#4-Nipple leaking at hammer union (red flag) DV Controllers at Separators venting needs maintenance. Stains around compressor needs remediation. On 11/7/19, after receiving notice from Operator, RW conducted a re-inspection. Operator resolved —issues