Loading...
2019.11.25_COD_FollowUp Gas Well Inspection Type 2019 Annual C0F Inspections Inspection Cycle 2nd Half _ DENTOR 24hr Phone 817-841-8885 Well Operator Bedrock Inspection Date 10-31-19 Record Close Date 11-21-19 Active Padsite Name 146 ROBSON RANCH 500 Jurisdiction CoD Re-Inspection Date 11-21-19 Site Address 7593 Florence Rd. Padsite Type Multi Well Rt 20 2nd Follow-up Inspection Ordinance Reg 2005-223 Rod Weatherby Inspected by Y Inspection Status Closed Plat/Site Permit No Plan No Lease Name .RRC Id Avi No. Spud Date Impact 1109-0235 GWP08-0031 ROBSON RANCH 502H 258247 12133862 3/28/2010 Moderate 1109-0236 GWP08-0031 ROBSON RANCH 505H 258255 12133910 3/30/2010 Moderate 1109-0237 GWP08-0031 ROBSON RANCH 503H 258402 12133864 1/17/2010 Moderate 1109-0238 GWP08-0031 ROBSON RANCH 504H 258532 12133863 2/19/2010 Moderate 1109-0239 GWP08-0031 ROBSON RANCH 501H 259581 12133860 3/11/2010 Moderate INSPECTION CHECK LIST Signs/Labels General Location I Operator Name • Good Need Resolved Fencing • Good Need Resolved Site Address • Good Need Resolved Entry Gate Locked • Good Need Resolved Well Name • Good Need Resolved Site Surface • Good Need Resolved 24hr.Phone No • Good Need Resolved Stains • Good Need Resolved RRC&Api No Good Need • Resolved Trash/Debris • Good Need Resolved No Smoking • Good Need Resolved Weeds/Brush • Good Need Resolved Reflective/Lighting • Good Need Resolved Oders/Fumes/Dust • Good Need Resolved Wellhead Sign • Good Need Resolved Site Lighting • Good Need Resolved Tank Battery Good Need Resolved Landscaping • Good Need Resolved Storage Tank Labels • Good Need Resolved Erosion Control • Good Need Resolved Facility Equipment I Miscellaneous I Wellhead Paint • Good Need Resolved Electric Lines Safe • Good Need Resolved Wellhead Leaks • Good Need Resolved Pipeline Markers • Good Need Resolved Tank Battery Paint • Good Need Resolved Layout per Site Plan • Good Need Resolved Tank Battery Leaks Good Need • Resolved Tank Integrity • Good Need Resolved No Wells Approved Db Level @ Inspection Containment Integrity • Good Need Resolved Fire Dept. Drip Pots@ Load • Good Need Resolved Lightning Arresting • Good Need Resolved Fire Lane Access Referred Tank Level Activated Referred Equip Height • Good Need Resolved Foam Lines Referred Pit Fencing Referred Accessible ESD Referred Auto Safety Valve Referred Inspection Comments At Entrance sign, 505H needs correct RRC#, correct number is 258255. Sep 503-DV controller venting needs repair(red flag). Recommend cleaning Well head resulting from workover and dressing up on.On 11/21/19, RW conducted a re-inspection. Operator addressed issues Gas Well Inspection Type 2019 Annual - 1 Inspections Inspection C cle cOF — Jy 2nd Half _ DENTU J