Loading...
2020.05.11_COD_FollowUp _-IM000 Gas Well Inspection Type 2020 Annual `OF Inspections Inspection Cycle 1st Half _ DENTOR 24hr Phone g Inspection Date 4-16-20 888-225-8141 Well Operator sage Record Active Padsite Name 21 LONG TERM Pad Close Date 5-1-20 Jurisdiction COD Re-Inspection Date 5-1-20 Site Address 1896 Nail Rd Padsite Type Multi Well Rt 09 2nd Re-Inspection Date Ordinance Reg 2004-059 R Weatherby Inspected by y Inspection Status Closed Plat/Site Permit No Plan No Lease Name .RRC Id Aai No. Spud Date Impact 1109-0139 AGWP04 LONG TERM 1 207197 12132392 11/20/2004 Moderate 1405-0183 GWSP13 LONG TERM AGF(SA)1H 275134 12134453 6/7/2014 Moderate 1405-0184 GWSP13 LONG TERM AGF(SA)2H 275956 12134454 6/5/2014 Moderate 1405-0185 GWSP13 LONG TERM AGF(SA)3H 275141 12134455 5/31/2014 Moderate 1406-0609 GWSP13 LONG TERM BALDINGER(SA)1H 275150 12134456 7/15/2014 Moderate 1406-0617 GWSP13 LONG TERM BALDINGER(SA)2H 275140 12134457 7/17/2014 Moderate 1407-0039 GWSP13 LONG TERM BALDINGER(SA)3H 276745 12134458 7/16/2014 Moderate 1407-0398 GWSP13 LONG TERM RENDA(SA)1 H 276903 12134473 9/2/2014 Moderate 1407-0402 GWSP13 LONG TERM RENDA(SA)2H 277062 12134469 9/4/2014 Moderate 1407-0411 GWSP13 LONG TERM RENDA(SA)3H 277063 12134470 9/5/2014 Moderate 1407-0412 GWSP13 LONG TERM RENDA(SA)4H 277640 12134471 9/6/2014 Moderate 1407-0413 GWSP13 LONG TERM RENDA(SA)5H 276967 12134472 9/7/2014 Moderate INSPECTION CHECK LIST Signs/Labels General Location Facility Equipment Operator • Good Need Resolve Wellhead Paint • Good Need Resolve p Fencing • Good Need Resolve Site Address • Good Need Resolve Wellhead Leaks Good Need • Resolve Well Name • Good Need Resolves Entry Gate • Good Need Resolve Site • Good Need Resolve T Battery Paint • Good Need Resolve 24hr. Phone • Good Need Resolves Stains Good Need • Resolve T Battery Leaks Good Need • Resolve RRC/A i# • Good Need Resolve Tank Integrity • Good Need Resolve p Trash/Debris • Good Need Resolve No Smoking • Good Need Resolves Weeds/Brus • Good Need Resolve Containment • Good Need Resolve Reflective • Good Need Resolves Oders/Fumes/Dus • Good Need Resolve Drip Pots • Good Need Resolve Wellhead • Good Need Resolves Site Lighting • Good Need Resolve Lightning • Good Need Resolve • Good Need Resolve Equip Height • Good Need Resolve Tank Battery Landscaping • Good Need Resolve Tank Labels • Good Need Resolves Erosion • Good Need Resolve No Wells Approved Db Level Miscellaneous Electric Lines • Good Need Resolve Pipeline • Good Need Resolves Layout • Good Need Resolves Markers per Site Inspection Comments Leaks at Tubing connectors (red flagged)on Wells: LTR3H, LTB2H, LT131 H, LTA3H, (C, D, E, 1). Note: Kimray valve at LTR1 H (G)was found working properly and not leaking. Contacted operator and operator advised the top works of the valve was changed out. Separator R2H- DV Controller venting needs repair(red flagged). West Compressor-2nd Stage Separator Dv Controller venting needs repair. East Compressor-Oil stains need remediation. On 5/1/20, RW conducted a follow-up inspection of the well site.Operator resolved all items requiring further attention. Inspections Conducted by Third Party and COD Follow Up Third Party Inspection Date: 3-25-20 COD Follow Up Date: 5-1-20 Leaks:Well C compression 4/16/20,Operator made fitting,Well G kimray valve, repairs to Kimray valve on and Separator B both Well G. actuators;NORM: '00 �"� Separator B and AST C ❑l a...e Issues addressed O AST • B � NKrvEav�+ 1p © lb+nE Ar 5•rorp iM I • • L _ +2%4 -ice fMlr•5[nrny Npmmt y •A B• • ,0'E I��. ODern•on Vsn • E f G iY.. tO. � Gas Well Inspection Type 2020 Annual - 1 Inspections Inspection Cycle CITY -- JJy 1st Half _ DENTUN�