Loading...
2020.05.11_COD_FollowUp _-IM000 Gas Well Inspection Type 2020 Annual `OF Inspections Inspection Cycle 1st Half _ DENTOR 24hr Phone g Inspection Date 4-17-20 888-225-8141 Well Operator sage Record Active Padsite Name 25 BALDINGER Pad Close Date 5-4-20 Jurisdiction COD Re-Inspection Date 5-4-20 Site Address 10343 W. University Dr. Padsite Type Multi Well Rt 10 2nd Re-Inspection Date Ordinance Reg 2002-040 R Weatherby Inspected by y Inspection Status Closed Plat/Site Permit No Plan No Lease Name .RRC Id Avi No. Spud Date Impact 1108-0312 DVP01-0008 BALDINGER 3 192884 12131010 8/29/2002 Low 1410-0808 AGSP14 BALDINGER(SA)10H 280568 12134476 12/4/2015 Low 1410-0810 AGSP14 BALDINGER(SA)11 H 280570 12134477 12/3/2015 Low 1410-0812 AGSP14 BALDINGER(SA)12H 280566 12134478 12/5/2015 Low 1410-0813 AGSP14 MITCH ELL-BALDINGER(SA)5H 280567 12134492 12/6/2015 Low 1410-0815 AGSP14 MITCH ELL-BALDINGER(SA)6H 280569 12134479 12/4/2015 Low INSPECTION CHECK LIST Signs/Labels General Location Facility Equipment Operator • Good Need Resolve Wellhead Paint • Good Need Resolve p Fencing • Good Need Resolve Site Address • Good Need Resolve Wellhead Leaks Good Need • Resolve Well Name • Good Need Resolves Entry Gate • Good Need Resolve Site • Good Need Resolve T Battery Paint • Good Need Resolve 24hr. Phone • Good Need Resolves Stains • Good Need Resolve T Battery Leaks • Good Need Resolve RRC/A i# • Good Need Resolve Tank Integrity Good Need • Resolve p Trash/Debris • Good Need Resolve No Smoking • Good Need Resolves Weeds/Brus Good Need • Resolve Containment • Good Need Resolve Reflective • Good Need Resolves Oders/Fumes/Dus • Good Need Resolve Drip Pots • Good Need Resolve Wellhead • Good Need Resolves Site Lighting • Good Need Resolve Lightning • Good Need Resolve • Good Need Resolve Equip Height • Good Need Resolve Tank Battery Landscaping • Good Need Resolve Tank Labels • Good Need Resolves Erosion • Good Need Resolve No Wells Approved Db Level Miscellaneous Electric Lines • Good Need Resolve Pipeline • Good Need Resolves Layout • Good Need Resolver Markers per Site Inspection Comments @WH#12(D)-Tubing connections to Kimray leaking (red flagged). Tanks-West 1311,1310,1312 (C,G,I)Thief Hatches venting needs maintenance. Weed control needed along berm. On 5/4/20, RW conducted a follow-up inspection of the well site. Operator resolved all items requiring further attention. Inspections Conducted by Third Party and COD Follow Up Third Party Inspection Date: 3.25-20 COD Follow Up Date: 4-17-20 Leaks:AST A thief hatch Thief Hatch A was tested and enardo valve; ,.... and found to be working Secondary Containment: : ° '` properly. Water trapped water trapped underneath, underneath containment check integrity of lining ' ` ` ' is due to ground water below the containment ._, liner. Containment L integrity found good. Lowed: n A . ❑ saParaw • T •...• O AST �,r Q AlaWq Eq.1-0 • Fq b— 1.�1 OC•xvaam Patti OPam to Gas Well Inspection Type 2020 Annual - 1 Inspections Inspection Cycle CITY - Jy 1st Half _ DENTO J