2020.05.26_COD_Inspection _-IM000 Gas Well Inspection Type 2020 Annual
`OF Inspections Inspection Cycle 1st Half
_ DENTOR
24hr Phone Inspection Date 4-23-20
817-841-8885 Well Operator Bedrock
Record Close Date 5-15-20
Active Padsite Name 150 ROBSON RANCH 600
Jurisdiction COD Re-Inspection Date 5-15-20
Site Address 9500 Robson Ranch Rd.
Padsite Type Multi Well Rt 22 2nd Re-Inspection Date
Ordinance Reg 2005-223 R Weatherby Inspected by y Inspection Status Closed
Plat/Site
Permit No Plan No Lease Name .RRC Id Avi No. Spud Date Impact
1109-0231 GWP08-0033 ROBSON RANCH 601 H 254787 12133801 9/26/2009 Moderate
1109-0240 GWP08-0033 ROBSON RANCH 602H 261299 12133889 12/24/2009 Moderate
1109-0241 GWP08-0033 ROBSON RANCH 603H 260969 12133893 1/9/2010 Moderate
1109-0242 GWP08-0033 ROBSON RANCH 604H 260570 12133894 2/18/2010 Moderate
1109-0233 GWP08-0033 ROBSON RANCH 605H 257966 12133907 3/7/2010 Moderate
1109-0232 GWP08-0033 ROBSON RANCH 606H 257956 12133905 3/20/2010 Moderate
1109-0244 GWP08-0033 ROBSON RANCH 607H 264414 12133906 7/9/2010 Moderate
1109-0243 GWP08-0033 ROBSON RANCH 608H 260995 12133904 7/23/2010 Moderate
1109-0245 GWP08-0033 ROBSON RANCH 609H 263882 12133908 8/10/2010 Moderate
1109-0246 GWP08-0033 ROBSON RANCH 610H 260614 12133909 8/24/2010 Moderate
1109-0248 GWP08-0033 ROBSON RANCH 611 H 260722 12133917 9/5/2010 Moderate
1109-0247 GWP08-0033 ROBSON RANCH 612H 261261 12133916 9/20/2010 Moderate
INSPECTION CHECK LIST
Signs/Labels General Location Facility Equipment
Operator • Good Need Resolve Wellhead Paint • Good Need Resolve
p Fencing • Good Need Resolve
Site Address • Good Need Resolve Wellhead Leaks Good Need • Resolve
Well Name • Good Need Resolves Entry Gate • Good Need Resolve Site • Good Need Resolve T Battery Paint • Good Need Resolve
24hr. Phone • Good Need Resolves Stains • Good Need Resolve T Battery Leaks Good Need • Resolve
RRC/A i# • Good Need Resolve Tank Integrity • Good Need Resolve
p Trash/Debris • Good Need Resolve
No Smoking • Good Need Resolves Weeds/Brus • Good Need Resolve Containment • Good Need Resolve
Reflective • Good Need Resolves Oders/Fumes/Dus • Good Need Resolve Drip Pots Good Need Resolve
Wellhead • Good Need Resolves Site Lighting • Good Need Resolve Lightning • Good Need Resolve
Tank Battery Good Need Resolves Landscaping • Good Need Resolve Equip Height • Good Need Resolve
Tank Labels • Good Need Resolves Erosion • Good Need Resolve
No Wells Approved Db Level
Miscellaneous
Electric Lines • Good Need Resolve Pipeline • Good Need Resolves Layout • Good Need Resolves
Markers per Site
Inspection Comments
All equipment with issues are Red Flagged. @ WH-604 (J)Regulator venting needs repair. @Separators: 607 (B) Dv Controller venting,
608 (C) Regulator to DV Controller venting, 611 (F) DV Controller venting, 612 (G) DV Controller venting. On 5/15/20, RW conducted a
follow-up inspection of the well site. Operator addressed all items requiring further attention.
Inspections Conducted by Third Party and COD Follow Up
Third Party Inspection Date: 3-26-20 COD Follow Up Date: 4-23-20
Leaks:Separator D SepD actuator tested and
actuator,Separator F found working properly-
actuator,and Red -•� , DV Controller was found
Temporary AST thief hatch `.�•: working properly-
Temporary AST is a frac
' ----. tank-compliant. SepF
was tested and found
venting,and will check it
for compliance during Re-
"' inspection. 5/15/20
- O Inspection-issues
-• "� `°P" addressed
Gas Well Inspection Type 2020 Annual
- 1 Inspections Inspection Cycle CITYy 1st Half
_ DENTOM
,00�.