Loading...
2020.06.12_COD_FollowUp i_ Gas Well Inspection Type 2020 Annual Y Inspections Inspection Cycle 1st Half _ DENTON 24hr Phone g g Inspection Date 5-14-20 855-820-6008 Well Operator Ea lerid e Record Close Date 6-10-20 Active Padsite Name 47 Vaughn 1 H Jurisdiction CoD Re-Inspection Date 6-10-20 Site Address 3502 Jim Christal Rd. Padsite Type Single Well Rt 03 2nd Re-Inspection Date Ordinance Reg 2005-223 R Weatherby Inspected by y Inspection Status Closed Plat/Site Permit No Plan No Lease Name .RRC Id ADi No. Spud Date Impact 1109-0356 GWP08-0020 Vaughn 1 H 260527 12132624 7/3/2005 Moderate INSPECTION CHECK LIST Signs/Labels General Location Facility Equipment Operator • Good Need Resolve Wellhead Paint • Good Need Resolve p Fencing • Good Need Resolve Site Address • Good Need Resolve Wellhead Leaks • Good Need Resolve Well Name • Good Need Resolves Entry Gate • Good Need Resolve Site • Good Need Resolve T Battery Paint • Good Need Resolve 24hr. Phone • Good Need Resolves Stains • Good Need Resolve T Battery Leaks Good Need • Resolve RRC/A i# Good Need • Resolve Tank Integrity • Good Need Resolve p� Trash/Debris • Good Need Resolve Containment • Good Need Resolve No Smoking • Good Need Resolves Weeds/Brus • Good Need Resolve Reflective • Good Need Resolves Oders/Fumes/Dus • Good Need Resolve Drip Pots • Good Need Resolve Wellhead • Good Need Resolves Site Lighting • Good Need Resolve Lightning • Good Need Resolve • Good Need Resolve Equip Height • Good Need Resolve Tank Battery Landscaping • Good Need Resolve Tank Labels • Good Need Resolves Erosion • Good Need Resolve No Wells Approved Db Level Miscellaneous Electric Lines • Good Need Resolve Pipeline • Good Need Resolves Layout • Good Need Resolves Markers per Site Inspection Comments Entrance sign needs current RRC#posted. Separator(A) Dv Controller venting needs repair(red flag). Tank(A)Hi Liquid Level Shut off -Kimray controller venting needs repair. On 6/10/20, RW conducted a follow-up inspection of the well site.Operator resolved all items requiring further attention Inspections Conducted by Third Party and COD Follow Up Third Party Inspection Date: 4-6-20 COD Follow Up Date: 6-10-20 Leaks:AST A enardo valve Issues were addressed and DV controller L°and: Q wr ... r.■.■.■■■. . S.p„■1„ AST • ^ AntMryEWOm♦nl A. • ♦ .• • Fan.Lrws • .. .. ■ upwww AV s•vphp POMI lZ■ ■ ■ A g M •�.�■ 00nwrn0 A.simpkq Port 4" Wind Dream Clo� • �.y•�������•• �� F.na■M•Svea+uq Algmienl .r ■ '•■• l•-I o0••n00n P■" 1.�• O�