2020.06.12_COD_FollowUp i_ Gas Well Inspection Type 2020 Annual Y Inspections Inspection Cycle 1st Half _ DENTON 24hr Phone g g Inspection Date 5-20-20 855-820-6008 Well Operator Ea lerid e Record Close Date 6-10-20 Active Padsite Name 77 MAYDAY-MASON UNIT Jurisdiction CoD Re-Inspection Date 6-10-20 Site Address 2052 S.Bonnie Brae Padsite Type Single Well Rt 31 2nd Re-Inspection Date Ordinance Reg 2002-040 R Weatherby Inspected by y Inspection Status Closed Plat/Site Permit No Plan No Lease Name .RRC Id Aoi No. Spud Date Imr)act 1109-0135 GWP02-0005 MAYDAY-MASON UNIT 2H 191995 12131351 5/8/2002 High INSPECTION CHECK LIST Signs/Labels General Location Facility Equipment Operator • Good Need Resolve Wellhead Paint • Good Need Resolve p Fencing • Good Need Resolve Site Address • Good Need Resolve Wellhead Leaks • Good Need Resolve Well Name • Good Need Resolves Entry Gate • Good Need Resolve Site • Good Need Resolve T Battery Paint • Good Need Resolve 24hr. Phone • Good Need Resolves Stains • Good Need Resolve T Battery Leaks Good Need • Resolve RRC/A i# • Good Need Resolve Tank Integrity Good Need • Resolve p� Trash/Debris • Good Need Resolve Containment • Good Need Resolve No Smoking • Good Need Resolves Weeds/Brus • Good Need Resolve Reflective • Good Need Resolves Oders/Fumes/Dus • Good Need Resolve Drip Pots • Good Need Resolve Wellhead • Good Need Resolves Site Lighting • Good Need Resolve Lightning • Good Need Resolve • Good Need Resolve Equip Height • Good Need Resolve Tank Battery Landscaping • Good Need Resolve Tank Labels • Good Need Resolves Erosion • Good Need Resolve No Wells Approved Db Level Miscellaneous Electric Lines • Good Need Resolve Pipeline • Good Need Resolves Layout • Good Need Resolves Markers per Site Inspection Comments At compressor DV controller venting needs repair(red flag), Open ended valve (on discharge side)leaking needs repair. At Separator, Regulator at supply pot leaking at tubing connector(red flag). Stairway landing missing top hand rail (red flag) . On 6/4/20 RW and AP conducted a spot inspection. DV controller at compressor was venting. All other issues were addressed . On 6/10/20, RW conducted a follow-up inspection of the well site. Operator resolved all items requiring further attention Inspections Conducted by Third Party and COD Follow Up Third Party Inspection Date: 4-7-20 COD Follow Up Date: 5-20-20 Leaks:AST B enardo Enardo valve working valve C �� Lacend properly 1 A O AST • A Nptt.V EQ.V'_A �/ ,. 9 • F—Lm L,. . ® Upw A.S mv"P-1 '® D.w 4 Ar S Vk V Pont ............. saro Saenptnq Po./ - ' tiw,a Dwctm ie, A• OPedw