Loading...
2020.06.12_COD_FollowUp i_ Gas Well Inspection Type 2020 Annual Y Inspections Inspection Cycle 1st Half _ DENTON 24hr Phone g g Inspection Date 5-21-20 855-820-6008 Well Operator Ea lerid e Record Close Date 6-10-20 Active Padsite Name 81 CHAMBERLAIN-ELDER Jurisdiction CoD Re-Inspection Date 6-10-20 Site Address 3900 Roselawn Padsite Type Multi Well Rt 36 2nd Re-Inspection Date Ordinance Reg 2014-084 R Weatherby Inspected by y Inspection Status Closed Plat/Site Permit No Plan No Lease Name .RRC Id Api No. Spud Date Impact 1106-0500 GWP02-0024 CHAMBERLAIN-ELDER UNIT 1 206947 12132411 09/14/2004 High 1106-0501 GWP02-0024 CHAMBERLAIN-ELDER UNIT 2H 238803 12133178 3/8/2008 High 1106-0502 GWP02-0024 CHAMBERLAIN-ELDER UNIT 3H 239252 12133263 1/25/2008 High INSPECTION CHECK LIST Signs/Labels General Location Facility Equipment Operator • Good Need Resolve Wellhead Paint • Good Need Resolve p Fencing • Good Need Resolve Site Address • Good Need Resolve Wellhead Leaks Good Need • Resolve Entry Gate • Good Need Resolve Well Name • Good Need Resolves Site Good Need • Resolve T Battery Paint • Good Need Resolve 24hr. Phone • Good Need Resolves Stains Good Need • Resolve T Battery Leaks Good Need • Resolve RRC/A i# • Good Need Resolve Tank Integrity Good Need • Resolve p Trash/Debris • Good Need Resolve No Smoking • Good Need Resolves Weeds/Brus Good Need • Resolve Containment Good Need • Resolve Reflective • Good Need Resolves Oders/Fumes/Dus • Good Need Resolve Drip Pots • Good Need Resolve Wellhead • Good Need Resolves Site Lighting • Good Need Resolve Lightning • Good Need Resolve • Good Need Resolve Equip Height • Good Need Resolve Tank Battery Landscaping • Good Need Resolve Tank Labels • Good Need Resolves Erosion • Good Need Resolve No Wells Approved Db Level Miscellaneous I Electric Lines • Good Need Resolve Pipeline • Good Need Resolves Layout • Good Need Resolves Markers per Site Inspection Comments Lease road has pools of water(holding water), ruts, holes and errosion cuts needs repair. Well-head (well C)tubing connector leaking needs repair(red flag), Chem Tank pump leaking needs repair(red flag). Well A tubing connector leaking needs repair(red flag). Separators A, C, Dv controllers venting needs repair(red flag). Tanks B,C thief hatches venting needs repair(red flag). Containment liner flange attaching liner to wall is separated and not sealing resulting in Containment leaks. Oil Stains where compressor was installed needs remediation. Weed control needed. On 6/4/20, RW&AP conducted a spot inspection. Thief Hatches B&C need repair. All other issues were addressed. On 6/10/20, RW conducted a follow-up inspection of the well site. Operator resolved all items requiring further attention I Inspections Conducted by Third Party and COD Follow Up Third Party Inspection Date: 4-7-20 COD Follow Up Date: 5-20-20 Corrosion: AST piping Corrosion reported is •� ■ c piping that was taken out of service prior to the MGS •......■ C A— inspection. ........... �__