Loading...
2020.06.22_COD_FollowUp _.,./ Gas Well Inspection Type 2020 Annual Cp , Inspections Inspection Cycle 1 st Half _ DENTON 24hr Phone 855-820-6008 Well Operator Eagleridge Inspection Date 5-19-20 Record Close Date 6-19-20 Active Padsite Name 75 Mayday-Lattimore Pad Jurisdiction CoD Re-Inspection Date 6-19-20 Site Address 1522 S I-35 Padsite Type Multi Well Rt 25 2nd Re-Inspection Date Ordinance Reg 2010-196 R Weatherby Inspected by y Inspection Status Closed Plat/Site 'ermit No Plan No Lease Name . RRC Id Api No. Spud Date Impact 1109-0143 GWP10-0015 MAYDAY-LATTI MORE GAS UNIT 1H 264186 12134126 5/4/2011 High 1201-0467 GWP10-0015 Mayday-Lattimore Gas Unit 2H 267776 12134173 3/29/2012 High 1304-0001 GWP10-0015 Mayday-Mason Unit 3H 273100 12134365 4/27/2013 High 1304-0004 GWP10-0015 Mayday-Mason Unit4H 274427 12134366 5/15/2013 High 1308-0648 GWP10-0015 Mayday-UNT 5H 275569 12134414 8/29/2013 High INSPECTION CHECK LIST Signs/Labels General Location Facility Equipment Operator • Good Need Resolve Wellhead Paint • Good Need Resolve p Fencing • Good Need Resolve Site Address • Good Need Resolve Wellhead Leaks • Good Need Resolve Well Name • Good Need Resolve Entry Gate • Good Need Resolve Site • Good Need Resolve T Battery Paint • Good Need Resolve 24hr. Phone • Good Need Resolves Stains • Good Need Resolve T Battery Leaks Good Need • Resolve RRC/A i# • Good Need Resolve Tank Integrity Good Need • Resolve p• Trash/Debris • Good Need Resolve No Smoking • Good Need Resolves Weeds/Brush • Good Need Resolve Containment • Good Need Resolve Reflective • Good Need Resolves Oders/Fumes/Dus • Good Need Resolve Drip Pots • Good Need Resolve Wellhead • Good Need Resolves Site Lighting • Good Need Resolve Lightning • Good Need Resolve • Good Need Resolve Equip Height • Good Need Resolve Tank Battery Landscaping • Good Need Resolve Tank Labels Good Need • Resolve Erosion • Good Need Resolve No Wells Approved Db Level IMiscellaneous I Electric Lines • Good Need Resolve Pipeline • Good Need Resolves Layout • Good Need Resolves Markers per Site Inspection Comments Tanks A,D missing Hazcom labels. Tank C Thief Hatch venting needs repair(red flag). Compressor is venting over 20% lel from engine, needs to be checked by mechanic. Kimray 30 HPG Pilot near compressor venting needs repair(red flag). Separators A,B,C,E,F-DV controllers venting needs repair(red flag). Recommend securing Stairway landing to braces. On 6/19/20, RW&AP conducted a follow- up inspection of the well site. Operator resolved all items requiring further attention. I Inspections Conducted by Third Party and COD Follow Up I Third Party Inspection Date: 4.7.20 COD Follow Up Date: 6-19-20 Leaks: Separator B DV Issues resolved controller, Separator C DV controller,AST A _ enardo valve,AST B Low* n thief hatch, and ❑ Compressor A kimray 0 valve;Corrosion: ;�, r-q-g O •» separator piping and AST piping ...... .... ---- . _ WMdN S.1yWQ fbry ABCOC ' • t • •C --- m 0..•..gN9.^'W4 Pow• II� • AI •. ...... .........�• Nvo Pnomlm ;.�ua.mm on Ej