Loading...
2020.06.25_COD_FollowUp i_ Gas Well Inspection Type 2020 Annual Y Inspections Inspection Cycle 1st Half _ DENTON 24hr Phone g g Inspection Date 5-22-20 855-820-6008 Well Operator Ea lerid e Record Close Date 6-24-20 Active Padsite Name 119 ACME Brick D Pad Jurisdiction CoD Re-Inspection Date 6-24-20 Site Address 163 N. 135 Padsite Type Multi Well Rt 55 2nd Re-Inspection Date Ordinance Reg 2002-040 R Weatherby Inspected by y Inspection Status Closed Plat/Site Permit No Plan No Lease Name .RRC Id Api No. Spud Date Impa` 1108-0058 GWP02-0013 ACME BRICK"D" 1H 199511 12131340 10/15/2003 Low 1312-0045 See Ord. No. ACME Brick D 3H 277128 12134428 11/20/2013 Low 1312-0046 See Ord. No. ACME Brick D 4H 274658 12134429 12/5/2013 Low INSPECTION CHECK LIST Signs/Labels General Location Facility Equipment Operator • Good Need Resolve Wellhead Paint • Good Need Resolve p Fencing • Good Need Resolve Site Address • Good Need Resolve Wellhead Leaks Good Need • Resolve Entry Gate • Good Need Resolve Well Name • Good Need Resolves Site • Good Need Resolve T Battery Paint • Good Need Resolve 24hr. Phone • Good Need Resolves Stains • Good Need Resolve T Battery Leaks Good Need • Resolve RRC/A i# • Good Need Resolve Tank Integrity Good Need • Resolve p Trash/Debris • Good Need Resolve No Smoking • Good Need Resolves Weeds/Brus Good Need • Resolve Containment • Good Need Resolve Reflective • Good Need Resolves Oders/Fumes/Dus • Good Need Resolve Drip Pots • Good Need Resolve Wellhead • Good Need Resolves Site Lighting • Good Need Resolve Lightning • Good Need Resolve Tank Battery Good Need • Resolves Landscaping • Good Need Resolve Equip Height • Good Need Resolve Tank Labels • Good Need Resolves Erosion • Good Need Resolve No Wells Approved Db Level Miscellaneous I Electric Lines • Good Need Resolve Pipeline • Good Need Resolves Layout • Good Need Resolves Markers per Site Inspection Comments Tank Battery sign for Well#3 and#4 are missing the RRC Id#'s. WellHead#4-Asco pilot leaking needs repair(red flag). Wellhead#3- 4-way cross on flowline leaking needs repair(red flag). Wellhead#1 heavy corrosion on flowline and off Casing needs repair(red flag) East Separator DV controller venting needs repair(red flag). Tank#3(NW corner)Top of tank where thief hatch is attached has corroded and can not seal properly. needs repair(red flag) Tank#3 has seeping hole needs to be repaired. Weed control needed. On 6-24-20,AP conducted a follow-up inspection of the well site with Jeff Smith attending. Operator resolved all issues requiring further attention. I Inspections Conducted by Third Party and COD Follow Up I Third Party Inspection Date: COD Follow Up Date: