2020.06.25_COD_FollowUp i_ Gas Well Inspection Type 2020 Annual
Y Inspections Inspection Cycle 1st Half
_ DENTON
24hr Phone g g Inspection Date 5-22-20
855-820-6008 Well Operator Ea lerid e
Record Close Date 6-24-20
Active Padsite Name 119 ACME Brick D Pad
Jurisdiction CoD Re-Inspection Date 6-24-20
Site Address 163 N. 135
Padsite Type Multi Well Rt 55 2nd Re-Inspection Date
Ordinance Reg 2002-040 R Weatherby Inspected by y Inspection Status Closed
Plat/Site
Permit No Plan No Lease Name .RRC Id Api No. Spud Date Impa`
1108-0058 GWP02-0013 ACME BRICK"D" 1H 199511 12131340 10/15/2003 Low
1312-0045 See Ord. No. ACME Brick D 3H 277128 12134428 11/20/2013 Low
1312-0046 See Ord. No. ACME Brick D 4H 274658 12134429 12/5/2013 Low
INSPECTION CHECK LIST
Signs/Labels General Location Facility Equipment
Operator • Good Need Resolve Wellhead Paint • Good Need Resolve
p Fencing • Good Need Resolve
Site Address • Good Need Resolve Wellhead Leaks Good Need • Resolve
Entry Gate • Good Need Resolve
Well Name • Good Need Resolves Site • Good Need Resolve T Battery Paint • Good Need Resolve
24hr. Phone • Good Need Resolves Stains • Good Need Resolve T Battery Leaks Good Need • Resolve
RRC/A i# • Good Need Resolve Tank Integrity Good Need • Resolve
p Trash/Debris • Good Need Resolve
No Smoking • Good Need Resolves Weeds/Brus Good Need • Resolve Containment • Good Need Resolve
Reflective • Good Need Resolves Oders/Fumes/Dus • Good Need Resolve Drip Pots • Good Need Resolve
Wellhead • Good Need Resolves Site Lighting • Good Need Resolve Lightning • Good Need Resolve
Tank Battery Good Need • Resolves Landscaping • Good Need Resolve Equip Height • Good Need Resolve
Tank Labels • Good Need Resolves Erosion • Good Need Resolve No Wells Approved Db Level
Miscellaneous I
Electric Lines • Good Need Resolve Pipeline • Good Need Resolves Layout • Good Need Resolves
Markers per Site
Inspection Comments
Tank Battery sign for Well#3 and#4 are missing the RRC Id#'s. WellHead#4-Asco pilot leaking needs repair(red flag). Wellhead#3-
4-way cross on flowline leaking needs repair(red flag). Wellhead#1 heavy corrosion on flowline and off Casing needs repair(red flag)
East Separator DV controller venting needs repair(red flag). Tank#3(NW corner)Top of tank where thief hatch is attached has
corroded and can not seal properly. needs repair(red flag) Tank#3 has seeping hole needs to be repaired. Weed control needed. On
6-24-20,AP conducted a follow-up inspection of the well site with Jeff Smith attending. Operator resolved all issues requiring further
attention.
I Inspections Conducted by Third Party and COD Follow Up I
Third Party Inspection Date: COD Follow Up Date: