2020.06.25_COD_FollowUp i_ Gas Well Inspection Type 2020 Annual
Y Inspections Inspection Cycle 1st Half
_ DENTON
24hr Phone g g Inspection Date 5-19-20
855-820-6008 Well Operator Ea lerid e
Record Close Date 6-24-20
Active Padsite Name 65 Rayzor West 12 Pad
Jurisdiction CoD Re-Inspection Date 6-24-20
Site Address 2952 Airport Rd
Padsite Type Multi Well Rt 24 2nd Re-Inspection Date
Ordinance Reg 2013-014 R Weatherby Inspected by y Inspection Status Closed
Plat/Site
Permit No Plan No Lease Name .RRC Id Api No. Spud Date Impact
1307-0048 Agwp10 Rayzor West Gas Unit 12H#1 276949 12134382 7/4/2013 High
1307-0064 Agwp10 Rayzor West Gas Unit 12H#2 275601 12134383 7/7/2013 High
1307-0070 Agwp10 Rayzor West Gas Unit 12H#3 274416 12134384 10/11/2013 High
1307-0071 Agwp10 Rayzor West Gas Unit 12H#4 274980 12134385 11/9/2013 High
1108-0598 GWP06 Rayzor West Gas Unit 12H#5D 255643 12132952 9/11/2006 High
INSPECTION CHECK LIST
Signs/Labels General Location Facility Equipment
Operator • Good Need Resolves Fencing • Good Need Resolve Wellhead Paint • Good Need Resolve
Site Address • Good Need Resolve Wellhead Leaks Good Need • Resolve
Well Name • Good Need Resolve Entry Gate • Good Need Resolve Site • Good Need Resolve T Battery Paint • Good Need Resolve
24hr. Phone • Good Need Resolves Stains • Good Need Resolve T Battery Leaks Good Need • Resolve
RRC/Api# • Good Need Resolves Trash/Debris Good Need • Resolve Tank Integrity Good Need • Resolve
No Smoking • Good Need Resolve Containment Good Need • Resolve
Weeds/Brus Good Need • Resolve
Reflective • Good Need Resolves Oders/Fumes/Dus • Good Need Resolve Drip Pots • Good Need Resolve
Wellhead • Good Need Resolves Site Lighting • Good Need Resolve Lightning • Good Need Resolve
Tank Battery • Good Need Resolves Landscaping • Good Need Resolve Equip Height • Good Need Resolve
Tank Labels Good Need • Resolves Erosion • Good Need Resolve
No Wells Approved Db Level
Miscellaneous
Electric Lines • Good Need Resolve Pipeline • Good Need Resolves Layout • Good Need Resolves
Markers per Site
Inspection Comments
Weed Control needed. Chem Tank needs Hazcom label. Surplus Tank on location needs to be removed. Well#5-Choke stem packing
leaking needs repair(red flag). Separators E,F Dv controllers venting needs repair(red flag) Tanks C,D Thief hatches venting needs
repair(red flag). Containment in Northeast corner leaking onto ground into ditch leading to creek. On 6/19/20, RW,AP and Jeff Smith
conducted a followup inspection. Hole in NW corner of Containment liner not repaired, Sep E Dv controller still venting. a 2nd re-
inspection is scheduled for 7/19/20. On 6-24-20,AP conducted a follow-up inspection of the well site with Jeff Smith attending. Operator
resolved all issues requiring further attention.
Inspections Conducted by Third Party and COD Follow Up I
Third Party Inspection Date: 4-6-20 COD Follow Up Date: 5-19-20
Leaks: Separator B DV Sep B DV controller was
controller, AST A O tested and found working
enardo valve, AST E .. �W' properly. Compressor was
n shut down and pressure at
enardo valve, and
0. DV controllers were
Compressor A A ! O _„ tested and found not
pneumatic liquid level 0 AST- venting.
controller; Corrosion: ^A�•,f..
AST piping A • ��-
0
\......r. •A•C D E
• A fnN SnWifbv
• C
• A, 4f 1MY dom Ibl
OT-a-