IFB 7154 - Addendum 1SHADY OAKSDR
COLORA
DOBLVD SPENCER RD GLENNGARY WAYS TRINITY RDMILLS RD LAKEVIEWBLVDBLAGG RDAUDRA LN
CARDINAL DRN MAYHILL RDS MAYHILL RDGRISSOM RDMACK DRSPRINGTREE STBELLAIRE DRMOCKINGBIRD LNN CARPENTER RDDUCHESS DRLANE DUCHESS
DENTON
McKINNEYSTREET
Mc
KI
NNEYS
T
RE
ETMINGO RD
AUDRALN
CAMPBELLLN288
380
380
35E
77
35E
288 S FORK DRWOODROWLNI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-GCV01.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-GCV01.dgn1:404:37:24 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLPhone (214) 871-3311 Fax (214) 871-0757
1717 McKinney Avenue, Suite 1400
Dallas, Texas 75202-1236
CONSTRUCTION PLANS FOR
CITY OF DENTON, TEXAS
CHRIS WATTSMAYOR..................
CITY COUNCIL
DEB ARMINTOR
PAUL MELTZER
TODD HILEMAN
COUNCIL MEMBER........
COUNCIL MEMBER........
GERARD HUDSPETH
KEELY G. BRIGGS
JOHN RYAN
TODD ESTES, P.E.
COUNCIL MEMBER.....
COUNCIL MEMBER...........
CITY MANAGER..........
DESIGN SPEED = 40 MPH
LOCATION MAP
NTS
LOCATION
PROJECT
COUNCIL MEMBER.....
8 -23
FROM EAST OF LOOP 288 TO WEST OF GRISSOM ROAD
PROJECT LAYOUT
24 -49
50 -53
54 -66
67 -84
85 -88
89 -94
95 -
-
-
-
-
-
-
-
3 -7
DRAINAGE DETAILS
192
195
203 218
219 227
228 234DIRECTOR OF
CAPITAL PROJECTS...
PROJECT NO. 880005
JESSE DAVISCOUNCIL MEMBER.........
TRAFFIC CONTROL DETAILS
TYPICAL SECTIONS
DEMOLITION PLAN
PAVING PLAN & PROFILE
PAVING DETAILS
TRAFFIC SIGNAL PLAN
TRAFFIC SIGNAL DETAILS
PAVEMENT MARKING AND SIGNAGE PLAN
PAVEMENT MARKING AND SIGNAGE DETAILS
CROSS-SECTIONS
DRAINAGE AREA MAP
DRAINAGE CALCULATIONS
DRAINAGE PLAN & PROFILE
LATERAL PROFILES
247-235
250-248
276-251
EROSION CONTROL PLAN
EROSION CONTROL DETAILS
WATER PLAN & PROFILE
298-278
300-299
WASTEWATER PLAN & PROFILE
311-302
LIGHTING PLAN
LIGHTING & ELECTRICAL DETAILS
SIDEWALK PLAN
117
118 127
128 138
139
196
-202196
277
COVER SHEET1
DESCRIPTIONSHEET NO.
PHASE 2
McKINNEY STREET
SD-1 -SD-16 CITY OF DENTON STANDARD DETAILS
TRAFFIC CONTROL SEQUENCE OF CONSTR.
2 GENERAL NOTES
KENNETH A. ROBERTS
55446P
ROFES
SIONAL ENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
DATE: SEPTEMBER 4, 2019
REG. NO. 55446
KENNETH A ROBERTS, P.E.
TO THIS PROJECT.
BY THE ENGINEER AS APPLICABLE
DRAWINGS HAVE BEEN DESIGNATED
TO THESE CONSTRUCTION
THE STANDARD DETAILS ATTACHED
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
GENERAL NOTES
UTILITY CONTACTS
2
LARRY BALDWIN
LARRY GUAY
GRAHAM WALDEN
CASEY PATTERSON
KENT KONKLE
REBECCA DIVINEY
JAMES ANDREWS
P.S. ARORA
COY WERNER
TOBY HAMM
OMAR CAMPOS
CONTACT PERSON
ONCOR
FRONTIER
DENTON ISD FIBER
DENTON MUNICIPAL ELECTRIC
CITY OF DENTON-WATER
CITY OF DENTON-WATER
CITY OF DENTON-WATER
CITY OF DENTON-TRAFFIC
CITY OF DENTON-STORM
CITY OF DENTON-SEWER
CITY OF DENTON-SEWER
CITY OF DENTON-FIBER
CITY OF DENTON-AFTER HOURS DISPATCH
CHARTER/SPECTRUM
ATMOS ENERGY
COMPANY
(817)215-6184
(870)215-5564
(940)369-0576
(940)349-7513
(940)349-7176
(940)349-7181
(940)349-8461
(940)349-8462
(940)349-7116
(940)349-7189
(940)349-7300
(940)349-7459
(940)349-7000
(817)298-3586
(940)380-7463
PHONE
4.
3.
2.
1.
III. TRAFFIC CONTROL
II. CONSTRUCTION
4.
3.
2.
1.
I. GENERAL IV. DRAINAGE/EXCAVATION CONTINUED
IV. DRAINAGE/EXCAVATION
V. WATER/WASTEWATER
VI. ENVIRONMENTAL MANAGEMENT
3.
2.
1.
THIS WORK IS ALSO A COMPONENT OR INCIDENTAL.
THIS WORK IN THE CONTRACT UNIT PRICE FOR ITEMS OF WHICH
PROPOSAL OF THE CONTRACT DOCUMENTS. INCLUDE COST OF
THESE PLANS UNLESS SPECIFICALLY ESTABLISHED IN THE BID
THERE WILL BE NO SEPARATE PAYMENT FOR WORK SHOWN ON
CENTRAL TEXAS.
OF DENTON, PUBLIC WORKS CONSTRUCTION STANDARDS - NORTH
BE IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, CITY
ALL WATER LINE AND WASTEWATER LINE CONSTRUCTION SHALL
VERSION AS SUPPLEMENTED).
HIGHWAYS, STREETS, BRIDGES AND WATERLINES (MOST RECENT
TXDOT STANDARD SPECIFICATIONS FOR CONSTRUCTION OF
CONSTRUCTION STANDARDS - NORTH CENTRAL TEXAS, AND THE
PROJECT SPECIFICATIONS, CITY OF DENTON, PUBLIC WORKS
ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE
OFFICE.(940)349-8910.
SHALL BE DIRECTED TO THE DENTON ENGINEERING
NOTICE BEFORE BEGINNING CONSTRUCTION. THE NOTIFICATION
THE CONTRACTOR SHALL GIVE THE CITY A MINIMUM OF 1 WEEK
SHALL BE REMOVED PRIOR TO CITY APPROVAL.
REMOVED UNLESS OTHERWISE NOTED IN THE PLANS. NO TREE
ALL TREES WITHIN LIMITS OF CONSTRUCTION ARE TO BE
AND SHALL BE CONSIDERED SUBSIDIARY TO THE CONTRACT.
CONSTRUCTION SHALL BE GRASSED AS DIRECTED BY THE CITY
EROSION CONTROL. AREAS DISTURBED OUTSIDE THE LIMITS OF
SUSTAINING HEALTHY PLANT LIFE AND SEEDED OR SODDED FOR
CLEAN TOPSOIL, FREE OF STONES AND DEBRIS, CAPABLE OF
ARE NOT SURFACED SHALL BE TOPPED WITH FOUR (4) INCHES
ALL AREAS DISTURBED BY CONSTRUCTION ACTIVITIES WHICH
THE VARIOUS BID ITEMS.
FOR THIS WORK BUT IT SHALL BE CONSIDERED SUBSIDIARY TO
CONTROL, AS NECESSARY. NO DIRECT PAYMENT WILL BE MADE
THE CONTRACTOR WILL BE REQUIRED TO SPRINKLE FOR DUST
EROSION CONTROL ITEMS SHALL BE IN PLACE.
PRIOR TO BEGINNING ANY CONSTRUCTION, THE TEMPORARY
OTHERWISE INDICATED ON THE APPROVED CONSTRUCTION PLANS.
MAXIMUM CUT/FILL SLOPES SHALL BE 3:1 (H:V) UNLESS
SIDE OF PROPOSED ROAD AS PROPERTY.
ROAD FROM PROPERTY ADDRESS. TO BE RELOCATED TO SAME
ALL MAILBOXES THAT ARE CURRENTLY ON OPPOSITE SIDE OF
CONTRACTOR SHALL COORDINATE WITH PROPERTY OWNERS FOR
CONSTRUCTION ACTIVITIES.
DELIVERY WILL NOT BE INTERRUPTED AS A RESULT OF THE
CONSTRUCTION AND TAKE MEASURES TO ASSURE THAT MAIL
REPLACING ANY MAIL BOXES THAT ARE IN THE WAY OF
THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING AND
FINAL APPROVAL OF THE JOB.
THAN THE ORIGINAL AT THE CONTRACTOR'S EXPENSE PRIOR TO
BE REMOVED AND RESTORED WITH MATERIALS EQUAL OR BETTER
REMOVED, BUT WHICH IS DISTURBED BY CONSTRUCTION, SHALL
PAVEMENT WHICH IS NOT SCHEDULED TO BE ALTERED OR
ANY EXISTING SIDEWALK, CURB, DRIVEWAY, FENCING OR
INCIDENTAL TO THE PROJECT.
MEASURED OR PAID FOR DIRECTLY BUT SHALL BE CONSIDERED
AT ALL STREET TIE-IN'S. SAWCUTTING WILL NOT BE
CONTRACTOR SHALL "SAWCUT AND MATCH EXISTING PAVEMENT"
REQUIREMENTS.
AIR QUALITY CONTROL BOARD AND ALL CITY AND COUNTY
COMPLIANCE WITH THE REGULATIONS SET FORTH BY THE TEXAS
DISPOSAL OF ALL BRUSH, TRASH OR DEBRIS SHALL BE IN
ACCESS TO RESIDENCES DURING CONSTRUCTION.
CONTRACTOR IS REQUIRED TO MAINTAIN RESIDENTIAL AND FIRE
CURRENT REVISION.
TEXAS MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES,
OTHER DEVICES OF THE TYPE AND SIZE INDICATED IN THE
REMOVE ALL BARRICADES, WARNING SIGNS, FLASHERS, AND
THE CONTRACTOR SHALL FURNISH, INSTALL, MAINTAIN, AND
REFLECTORIZED AND/OR ILLUMINATED.
ALL TRAFFIC CONTROL DEVICES USED AT NIGHT SHALL BE
TRAFFIC CONTROL DEVICES.
THE LATEST EDITION OF THE TEXAS MANUAL ON UNIFORM
CONTROL DEVICES, INCLUDING PLACEMENT, SHALL CONFORM TO
ALL SIGNS, BARRICADES, PAVEMENT MARKINGS AND TRAFFIC
MEASURES TO PREVENT SEDIMENTATION OF THE WATERWAY.
CROSSINGS OFF SITE OR INTO WATERWAYS WITHOUT TAKING
CONTAINING SUSPENDED SOLIDS FROM EXCAVATIONS AND STREAM
THE CONTRACTOR SHALL NOT DISCHARGE PUMPED WATER
MAINTENANCE WITHIN SPECIFIED TIME FRAMES.
PERFORM THE REQUIRED ROUTINE TEMPORARY CONTROL
THE CONTRACTOR IS RESPONSIBLE UNDER THIS CONTRACT TO
REMOVE EXCESS SEDIMENT TO SPOIL AREAS WITHIN 48 HOURS.
CONTRACTOR SHALL PERFORM ALL NECESSARY REPAIRS AND
SEDIMENTATION HAS EXCEEDED SPECIFICATIONS.THE
CONTROLS ARE INTACT AND FUNCTIONING, AND OBSERVE IF
RAINFALL IN EXCESS OF 0.5", TO DETERMINE IF THE
WEEKLY AND WITHIN 48 HOURS OF EVERY SIGNIFICANT
THE CONTRACTOR SHALL INSPECT THE CONTROLS AT LEAST
SEDIMENTATION CONTROLS.
AND/OR ADDITIONS MADE TO THE TEMPORARY EROSION AND
ADDITIONAL PAYMENT WILL BE MADE FOR ANY ADJUSTMENTS
INADEQUATE TO PREVENT OFF-SITE SEDIMENTATION. NO
TEMPORARY CONTROL PLAN IN AREAS WHERE IT IS OBSERVED
TO ADJUST LOCATIONS OR ADD FOOTAGE TO THE APPROVED
APPROVED PLANS.THE INSPECTOR MAY REQUIRE THE CONTRACTOR
AND DEBRIS FROM THE PROJECT IN ACCORDANCE WITH THE
IS COMPLETED TO PREVENT OFF-SITE TRANSPORT OF SEDIMENT
EROSION AND SEDIMENTATION CONTROLS UNTIL REVEGETATION
THE CONTRACTOR SHALL INSTALL AND MAINTAIN TEMPORARY
INCLUSIVE.
OTHER UTILITIES IS NOT GUARANTEED TO BE ACCURATE OR ALL
PLANS CONCERNING TYPE AND LOCATION OF UNDERGROUND AND
REFERENCE PURPOSES ONLY. THE INFORMATION SHOWN ON THESE
AVAILABLE DURING THE DESIGN PERIOD AND ARE FOR
PLANS ARE BASED ON THE MOST CURRENT INFORMATION
DAMAGE THERETO. UNDERGROUND UTILITIES SHOWN ON THESE
UNDERGROUND UTILITIES AS MAY BE NECESSARY TO AVOID
DETERMINATION AS TO THE TYPE AND LOCATION OF
CONTRACTOR IS RESPONSIBLE FOR MAKING HIS OWN
WORK THAT WOULD AFFECT UNDERGROUND UTILITIES. THE
DISTRICT OR COMPANY AT LEAST 48 HOURS BEFORE COMMENCING
THE CONTRACTOR SHALL CONTACT THE APPROPRIATE UTILITY
INSTALLED AROUND ALL MATERIAL STOCKPILES.
YEAR FLOOD PLAIN. EROSION CONTROL MEASURES SHALL BE
CONTRACTOR SHALL NOT STOCKPILE MATERIAL WITHIN THE 100
CONTRACTOR AT NO COST TO THE CITY.
CAUSED BY THE CONTRACTOR SHALL BE REMEDIED BY THE
DURING CONSTRUCTION. ANY DAMAGE TO IN SERVICE MANHOLES
EXISTING IN - SERVICE MANHOLES ARE TO BE PROTECTED
PROJECT.
CONSTRUCTION TRENCH PRIOR TO BEGINNING ANY WORK ON THE
SUPPORT WATER, STORM DRAIN OR OTHER LINES THAT SPAN THE
CONTRACTOR SHALL PREPARE AND PRESENT A PLAN ON HOW TO
CONTRACTOR'S OPERATIONS.
DONE TO SUCH EXISTING FACILITIES AS A RESULT OF THE
CONSTRUCTION. THE CONTRACTOR IS LIABLE FOR ALL DAMAGES
AND THE STRUCTURES BOTH ABOVE AND BELOW GROUND DURING
DRAINAGE PIPES, UTILITY SERVICES, ALL OTHER UTILITIES,
TELEPHONE CABLES, SANITARY SEWER LINES, ELECTRIC CABLES,
SUPPORT AND PROTECTION OF ALL UTILITY POLES. GAS MAINS,
THE CONTRACTOR SHALL MAKE NECESSARY PROVISION FOR THE
THE CONTRACTOR TO PROVIDE SAFE WORKING CONDITIONS.
CONSTITUTE A BASIS FORA DELAY OR COMPENSATION CLAIM BY
PLANS TO SHOW EXISTING POWER LINE LOCATIONS SHALL NOT
REIMBURSABLE BY THE CITY. FAILURE OF THE CONSTRUCTION
BORNE SOLELY BY THE CONTRACTOR AND WILL NOT BE
WORKING SAFELY AROUND EXISTING POWER LINES SHALL BE
THE MINIMUM APPROACH DISTANCE. COSTS ASSOCIATED WITH
ANYONE WORKING FROM AN ELEVATED POSITION STAYS OUTSIDE
CONTRACTOR MUST POST WARNING SIGNS AND ENSURE THAT
INVOLVED, AND THE PROTECTIVE MEASURES TO BE TAKEN.
AWARE OF THE LOCATION OF ANY POWER LINES, THE HAZARDS
IS RESPONSIBLE TO ENSURE THAT ALL PERSONS WORKING ARE
MEASURES ARE TAKEN BEFORE WORK IS STARTED. CONTRACTOR
DE-ENERGIZED AND GROUNDED OR THAT OTHER PROTECTIVE
OVERHEAD LINES, OSHA REQUIRES THAT POWER LINES BE
FROM ALL POWER LINES. WHERE CONSTRUCTION IS NEAR
ADMINISTRATION) REGULATIONS AND WORK A SAFE DISTANCE
FOLLOW OSHA (OCCUPATIONAL SAFETY AND HEALTH
TOWERS.
SHORING AND FOR PROTECTING ALL ELECTRICAL POLES AND
THE CONTRACTOR IS SOLELY RESPONSIBLE FOR DESIGNING ALL
THE POLE AND TOWER FOUNDATIONS ACTING ON THE SHORING.
SHORING TO ACCOUNT FOR ADDITIONAL SURCHARGE LOADS OF
UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL DESIGN THE
DISTRIBUTION POLES AND 25' OF TRANSMISSION TOWERS,
USED IN OPEN TRENCHES WITHIN 5 ' (ANY DIRECTION) OF
ELECTRIC COMPANIES TYPICALLY REQUIRE THAT SHORING BE
PROPERTY OWNERS.
PROPERTY WITHOUT WRITTEN PERMISSION FROM THE AFFECTED
NO EQUIPMENT OR MATERIAL SHALL BE DEPOSITED ON PRIVATE
WHICH EXISTED PRIOR TO THE PROJECT.
OPERATIONS TO A CONDITION AS GOOD OR BETTER THAN THAT
THE CONTRACTOR SHALL CLEAN UP AND RESTORE THE AREA OF
EASEMENT OR R.O.W.
LIMIT ACTIVITIES TO WITHIN THE EXISTING UTILITY
CONSTRUCTION EASEMENTS ARE AVAILABLE, CONTRACTOR SHALL
UTILITY EASEMENTS OR R.O.W. IN THE AREAS WHERE NO
THROUGH THE TEMPORARY CONSTRUCTION EASEMENTS. EXISTING
INGRESS AND EGRESS TO THE WORK SITE SHALL BE ONLY
EASEMENTS. UNLESS GRANTED BY THE PROPERTY OWNER,
CONDITIONS SET FORTH IN TEMPORARY CONSTRUCTION
CONTRACTOR SHALL BECOME FAMILIAR WITH THE TERMS AND
AUTHORIZED.
$5000 FOR EACH TREE WHICH IS REMOVED WHERE NOT
REPRESENTATIVE. THE CONTRACT AMOUNT WILL BE REDUCED BY
OR R.O.W. WITHOUT PRIOR APPROVAL OF THE OWNER'S
NO TREES MAY BE REMOVED OUTSIDE THE PERMANENT EASEMENTS
PRIOR TO THE CLOSURE OF THEIR ACCESS.
SHALL BE NOTIFIED BY THE CONTRACTOR TWO WORKING DAYS
OCCUPIED THAT WILL BE DENIED ACCESS TO THEIR DRIVEWAY
ACCESS MUST BE PROVIDED BY CONTRACTOR. ALL PROPERTIES
MULTIPLE INGRESS/EGRESS POINTS AVAILABLE OR ALTERNATE
EXISTING ROADS AND DRIVES IS INTERRUPTED MUST HAVE
DRIVES AT ALL TIMES. PROPERTIES WHERE ACCESS TO
PROVIDE ACCESS FOR LANDOWNERS AT EXISTING ROADS AND
CONSTRUCTION.
OF THE VIDEO TO THE CITY INSPECTOR PRIOR TO
SUBSIDIARY WORK. THE CONTRACTOR SHALL PROVIDE ONE COPY
THE PRE- CONSTRUCTION VIDEOTAPING SHALL BE CONSIDERED
IDENTIFICATION OF PROPERTY ADDRESS AND LINE DESIGNATION.
WORK. VIDEOS SHALL INCLUDE DATE NOTATION AND AUDIO
POTENTIALLY IMPACTED PRIVATE PROPERTY AREAS PRIOR TO
THE CONTRACTOR SHALL VIDEO THE PROJECT AND ALL
CONTRACT.
OF LETTERS SHALL BE CONSIDERED AS SUBSIDIARY TO THE
PERFORMING ANY WORK ON PRIVATE PROPERTY. DISTRIBUTION
CONTRACTOR SHALL NOTIFY OWNERS 48 HOURS IN ADVANCE OF
LETTERS SHALL BE FORWARDED TO THE CITY INSPECTOR. THE
AND TIME FRAME FOR DOING THE WORK. COPIES OF THE
CONTRACTOR CONTACTS, A DESCRIPTION OF WORK TO BE DONE,
LETTERS SHALL INCLUDE NAMES AND PHONE NUMBERS OF
OWNERS PRIOR TO BEGINNING WORK ON EACH PROPERTY. THE
THE CONTRACTOR SHALL DISTRIBUTE LETTERS TO ALL PROPERTY
LINES TO BE RELOCATED BY OTHERS.
EXISTING ELECTRICAL, TELEPHONE, GAS, FIBER AND CABLE TV
ENTIRE EXPENSE.
CONTRACTOR AS REQUIRED BY THE CITY AT THE CONTRACTOR'S
CONTRACTOR'S OPERATIONS WILL BE REMOVED BY THE
ANY OBSTRUCTIONS TO EXISTING DRAINAGE DUE TO THE
VARIOUS BID ITEMS.
DIRECTLY, BUT SHALL BE CONSIDERED SUBSIDIARY TO THE
PLUGGING OF PIPES OR CULVERTS WILL NOT BE PAID FOR
BLASTING WITHIN THIS PROJECT AREA WILL NOT BE PERMITTED.
REMAIN THE RESPONSIBILITY OF THE CONTRACTOR.
DESIGN, INSTALLATION, MAINTENANCE, AND REMOVAL WILL
EXCEEDING 5 FEET IN DEPTH. OVERALL TRENCH SAFETY
TRENCH SUPPORT SYSTEMS WILL BE REQUIRED IN ALL TRENCHES
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.
2.
1.
19.
18.
17.
16.
15.
14.
13.
12.
11.
10.
9.
8.
7.
6.
5.
4.
3.
CONCRETE BLOCKING.
THRUST RESTRAINT FOR WATERLINES SHALL BE PROVIDED BY
AND RESTRAINED.
AND RESTRAINED. ALL IN-LINE GATE VALVES SHALL BE "MJ"
ALL GATE VALVES ON AN OUTLET BRANCH SHALL BE "FLxMJ"
OUTLETS AND LATERALS SHALL BE "MJxFL".
WATERLINE FITTINGS SHALL BE "MJ", EXCEPT THAT TEES FOR
ALL WATERLINE FITTINGS SHALL BE DUCTILE IRON. ALL
BLOCKED.
ALL WATERLINE FITTINGS SHALL BE RESTRAINED AND CONCRETE
TO FINISHED GRADE PLUS 6".
C. MANHOLE RIMS/COVERS OUTSIDE OF PAVEMENT ADJUSTED
FINISHED GRADE.
B. MANHOLE RIMS/COVERS IN PAVEMENT ADJUSTED TO
A. VALVE STACKS/BOXES ADJUSTED TO FINISHED GRADE.
FOLLOWS:
UTILITIES THAT ARE TO REMAIN SHALL BE ADJUSTED AS
ALL VALVE STACKS/BOXES AND ALL MANHOLE RIMS/COVERS FOR
SEWER AT CROSSINGS.
VERTICAL SEPARATION BETWEEN SANITARY SEWER AND STORM
BETWEEN SANITARY SEWER AND WATERLINES AND 1 FT. MIN.
IN GENERAL, MAINTAIN 2' MIN. VERTICAL SEPARATION
CENTERLINE OF THE PIPELINE.
ABOVE THE PIPE), OR AS SHOWN ON THE PLANS, ALONG THE
INSTALLED ON TOP OF THE GRANULAR PIPE EMBEDMENT (18"
SANITARY SEWER PIPE UNDERNEATH. THE PIPE TAPE SHALL BE
SHALL CONTINUOUSLY INDICATE THE PRESENCE OF BURIED
TAPE OVER ALL SEWER LINES INSTALLED. THE PIPE TAPE
CONTRACTOR SHALL FURNISH AND INSTALL PIPE DETECTION
REPLACEMENT OF REMOVED CAPS.
CLEAN-UP ASSOCIATED WITH OPENING CLEAN OUTS AND FOR
AVAILABLE. THE CONTRACTOR WILL BE RESPONSIBLE FOR ALL
CONTRACTOR WILL BE ALLOWED TO OPEN CLEAN OUTS WHERE
RESULT DURING THE INSTALLATION OF NEW SEWER PIPE. THE
BUSINESSES, HOMES, OR BASEMENTS FROM BACKUP WHICH MAY
THE CONTRACTOR SHALL BE LIABLE FOR DAMAGES TO
OVERNIGHT.
CASE SHALL SERVICES BE ALLOWED TO REMAIN OUT OF SERVICE
SEWER CONNECTIONS IN WORKING ORDER AT ALL TIMES. IN NO
CONTRACTOR IS RESPONSIBLE FOR MAINTAINING WATER AND
LINES.
SERVICES SHALL BE RECONNECTED TO PROPOSED SEWER MAIN
AND REQUIRE CONTRACTOR VERIFICATION. ALL EXISTING
SERVICES SHOWN ARE APPROXIMATE IN NUMBER AND LOCATION
SERVICES ALONG EXISTING SANITARY SEWER MAINS. PROPOSED
CONTRACTOR SHALL USE TV TO LOCATE ALL SANITARY SEWER
PROPOSED SANITARY SEWER MAIN LINES AND SEWER SERVICES.
SEPARATION OF 9' (O.D. TO O.D.) FROM ALL EXISTING OR
ALL WATER SERVICES SHALL BE LOCATED AT A MINIMUM
SUBSIDIARY TO THE CONTRACT.
GRADE. ADJUSTMENT OF THESE ITEMS SHALL BE CONSIDERED
METERS, VAULTS AND ALL OTHER FACILITIES TO THE FINAL
ADJUST ALL EXISTING AND PROPOSED VALVE BOXES, WATER
12.
11.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-GNT01.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-GNT01.dgn1:404:37:26 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837NTS
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL 2019
SEP
GENERAL NOTES
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
CITY OF DENTON - McKINNEY STREET PHASE TWO1:80
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CHC01.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CHC01.dgn1:804:37:32 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
20 40 60 80
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
PARKING AREA
PA
RKING AR
EA
PARKING AREA
E
E
S
S
S
S
592.08
X CUT SET
29 58
7.72
5/
8" I
RS W/RANDOM
3
0
LOOP 288
7-ELEVEN INC
101 N LOOP 288
DENNIS J KOOP
3612 E McKINNEY STREET
McKINNEY BUILDING, LP
3612 E McKINNEY STREET
McKINNEY BUILDING, LP
3600 E McKINNEY STREET
McKINNEY BUILDING, LP
LOT 24A
LOT 1
LOT 1
LOT 1LOT 2R
LOT 1
LOT 1R
CAB. Y, PG. 121
16' UTILITY EASEMENT
CAB. Y, PG. 121
SIDEWALK EASEMENT
20' UTILITY & VOL. 1674, PG. 69UTILITY EASEMENTMAINTAINING PUBLIC VOL. 1115, PG. 421
60' POWERLINE EASEMENT
VOL. 1115, PG. 421
20' CONSTRUCTION EASEMENT
VOL. 1115, PG. 421
20' UTILITY EASEMENT
VOL. 1674, PG. 69
TO THE CITY
25' UTILITY EASEMENT
CAB. F, PG. 336
ELEC. EASEMENT
20' UTILITY &
CAB. F, PG. 336
& ELEC.EASEMENT
16' UTILITY
CAB. K, PG. 208
INGRESS & EGRESS EASEMENT
VARIABLE WIDTH CROSS-USE
VOL. 1029, PG. 281
TO THE CITY OF DENTON
75' UTILITY EASEMENT
VOL. 1029, PG. 281
UTILITY EASEMENT
75' MAINTAINING PUBLIC
DOC. # 2005-130810
VARIABLE WIDTH EASEMENT
VOL.
60
3, PG. 5
20EASEMENT16' PUBLI
C UTI
LI
TYVOL. 60
3, PG. 5
20EASEMENT16' PUBLI
C UTI
LI
TYVOL. 603, PG. 520
16' PUBLIC UTILITY EASEMENT
CA
B.
R, PG. 32EASEM
ENT20' PUB
LI
C
U
TI
LI
TYVOL. 1115, PG. 421EASEMENT 20' CONSTRUCTION VOL. 1115, PG. 418
TO THE CITY
20' UTILITY EASEMENT
CAB. Y, PG. 121
16' UTILITY EASEMENT
3621 E McKINNEY STREET
DENNIS J KOOP
3601 E McKINNEY STREET
PIONEER ORT INVESTMENTS INC
LOT 44
101 S LOOP 288
INVESTMENT COMPANY
SEJ ASSET MANAGEMENT &
COMMISIONER'S COURT MINUTES, DENTON COUNTY, TX
ATTACHED TO VOL. S, PAGE 366
RIGHT OF WAY EASEMENT DATED: 10-08-1947
88+00
89+00
91+0090+0086+0082+00 83+00 85+0084+00 87+00 10072+0010073+0010074+0010075+00 PC 86+94.15 PT 90+20.18V
V
V
PARKING AREA
E
PARKING AREA
S
S
S S
PARKING AREA
590.91
5/8" IRS W/RANDOM
31
E McKINNEY STREET
CCD-RLG DENTON I LP
3701 E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
3730 E McKINNEY STREET
LISA FONG LEUNG
100 N LOOP 288
100 NORTH LOOP 288, LLC
101 S LOOP 288
DNB INVESTMENTS LTD
LOOP 288
7-ELEVEN INC
LOT 1
LOT 1
LOT 1
LOT 1
LOT 1
LOT 41
LOT 24A
LOT 1VOL. 603, PG. 52016' PUBLIC UTILITY EASEMENTVOL. 603, PG. 520
EASEMENT
16' PUBLIC UTILITY
CAB. R, PG. 32EASEMENT
20' PUBLIC UTILITY CAB. D, PG. 191
16' UTILITY EASEMENT
CAB. XX, PG. XX
EASEMENT
PRIVATE DRAINAGE
CAB. D, PG. 15
UTILITY EASEMENT
20' PUBLIC
CAB. X, PG. XX
EASEMENT
8' PUBLIC UTILITY
CAB. O, PG. 264
EASEMENT
15' PUBLIC UTILITY
CAB. O, PG. 264
EASEMENT
10' UTILITY
101 S LOOP 288
INVESTMENT COMPANY
SEJ ASSET MANAGEMENT &
191 DUCHESS DRIVE
JBJ/CALDER FUND VII JOINT VENTURE
92+00
100+0099+00 101+0098+0094+0093+00 95+00 97+0096+00
PC 93+74.59 PT 94+85.56 PC 99+35.08McKINNEY STREETCARDINAL DRIVEMATCHLINE STA 91+50N LOOP 288S LOOP 288MATCHLINE STA 91+50DUCHESS DRIVE3
EX. R.O.W
EX. R.O.W
EX. R.O.W
EX. R.O.W
EX. R.O.W
EX. R.O.W
CV-1
354.41'S 63° 20' 05.00" ECV-2 CV-3
McKINNEY STREET
EX. R.O.W
EX. R.O.W
EX. R.O.W
N = 7128212.49
E = 2399828.06
DEG = 6° 29' 50.28"
T = 164.90'
L = 326.03'
= 21° 11' 00.00" RT
R = 881.84'
N = 7127954.53
E = 2400341.73
DEG = 1° 38' 13.28"
PI STA = 94+30.08
L = 110.97'
= 1° 49' 00.00" RT
T = 55.49'
R = 3,500.00'
CURVE 1 (CV-1)
CURVE 2 (CV-2)
N = 7127635.39
E = 2400929.96
DEG = 1° 05' 28.85"
L = 328.34'
= 3° 35' 00.00" LT
R = 5,250.00'
T = 164.22'
CURVE 3 (CV-3)MATCHLINE STA 101+50McKINNEY ST BEGIN TO 101+50
PROJECT LAYOUT
1,143.29'
S 84° 31' 05.00" E
354.41'S 63° 20' 05.00" E
449.52'
S 61° 31' 05.00" E
E: 2399330.32
N: 7127799.78
PC CV-2 93+74.59
E: 2399440.94
N: 7127790.94
PT CV-2 94+85.56
E: 2399888.40
N: 7127747.99
PC CV-3 99+35.08
CAB. R, PG. 32
EASEMENT
20' PUBLIC UTILITY
ELEV. 590.91
5/8" IRS RANDOM CAP
CONTROL POINT #31
EX. R.O.W STREETM
cKI
NNEY
E: 2399854.00
N: 7128188.52
STA 10073+29.69 LOOP 288
STA 88+88.74 McKINNEY STREET=
E: 2399663.92
N: 7128228.24
PC CV-1 86+94.15
E: 2399975.42
N: 7128138.49
PT CV-1 90+20.18
ELEV. 587.72
5/8" IRS RANDOM CAP
CONTROL POINT #30
ELEV. 592.08
"X" CUT SET
CONTROL POINT #29
PI STA = 88+57.17
PI STA = 100+99.25
E: 2400810.08
N: 7127700.52
CL DUCHESS DRIVE
STA 99+62.87 McKINNEY STREET
POINT
CONTROL POINTS
ELEV.NORTHING EASTING DESCRIPTION
592.08297128206.79 2399349.00
587.72307128217.29 2400020.41 5/8" IRS RANDOM CAP
"X" CUT SET
590.91317127818.45 2399652.90 5/8" IRS RANDOM CAP
CITY OF DENTON - McKINNEY STREET PHASE TWO1:80
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CHC02.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CHC02.dgn1:804:37:34 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
20 40 60 80
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
V
PARKING AREA
PARKING AREA
PARKING AREA
PARKING AREA
CONCRETE
E
PARKING AREA
PARKING AREA
PARKING AREA
24" HACKBERRY
DBL. 12" TREE
24" TREE
TRI 6" TREE
DBL. 10" HACKBERRY 18" ELM
6" TREE
TRI 4" TREE
QUAD 6" ELM
DBL. 8" HACKBERRY 6" ELM DBL. 6"/12" HACKBERRY DBL. 6" HACKBERRY DBL. 8" HACKBERRY
4" ELM
6" ELM 15" HACKBERRY10" CEDAR
DBL. 10" TREEDBL. 12" HACKBERRYDBL. 6" ELM
10" TREE
S S
586.24
X CUT SET
32
E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
LOT 27 CAB. D, PG. 15
20' PUBLIC UTILITY EASEMENT
CAB. O, PG. 264
10' UTILITY EASEMENT
CAB. B, PG. 7116' UTILITY EASEMENT
CAB. B, PG. 7125' UTILITY EASEMENT
E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
LOT 29 LOT 38
3801 E McKINNEY STREET
ANGEL & GRISELDA ENRIQUEZ
LOT 1R
3919/3921 E McKINNEY STREET
NSA PROPERTY HOLDINGS, LLC
LOT 1
191 DUCHESS DRIVE
JBJ/CALDER FUND VII JOINT VENTURE
LOT 1
3910 E McKINNEY STREET
SCOTTIE ADAMS
LOT 2
3912 E McKINNEY STREET
DUNCAN STREET COMMERCIAL LLC
LOT 3
3916 E McKINNEY STREET
EDWARD D & SHARYL K DIELEMAN
STREET
3918-3920 E McKINNEY
ORINGDERFF
LESLIE A & MICHAEL L
CAB. O, PG. 264
10' UTILITY EASEMENT
CAB. Y, PG. 289EASEMENT20' UTILITY
110+00
106+00
105+00 107+00
109+00
108+00104+00
103+00
102+00
PT 102+63.42 PC 104+55.99 PT 107+79.73PARKING AREA
PARKING AREA
CONCRETE
CONCRETE
E E
PARKING AREA
S
S
S
D
D
S
585.34
PK NAIL SET
33
S
VOL. 5039, PG. 01970
DRAINAGE EASEMENT
20' PERMANENT
LOT 4
STREET
3918-3920 E McKINNEY
ORINGDERFF
LESLIE A & MICHAEL L
LOT 3
3923 E McKINNEY STREET
3919 McKINNEY, LLC
LOT 152
STREET
McKINNEY
4001 E
DENTON
CITY OF
LOT 153
E McKINNEY STREET
CITY OF DENTON
LOT 154
4301 E McKINNEY STREET
CITY OF DENTON
LOT 159
4393 E McKINNEY STREET
KENNETH L & GLADYS F STOUT
LOT 161
LOT 5R1
3922 E McKINNEY STREET
GOEL VENTURES ONE, LLC
LOT 151 (PT)
E McKINNEY STREET (200' STRIP)
BCI REAL ESTATE VENTURES, LP
CAB. B, PG. 71
EASEMENT
25' UTILITYCAB. Y, PG. 289
EASEMENT
20' UTILITY
PG. 147
CAB. B,
EASEMENT
16' UTILITY
STREET
McKINNEY
4515 E
STOUT
& GLADYS F
KENNETH L
112+00111+00 115+00114+00 116+00 118+00117+00 119+00113+00
2
24+00223+0
0222+00221+00 PC 111+52.17 PC 116+81.83 PT 112+56.894MATCHLINE STA 110+50MATCHLINE STA 101+50MATCHLINE STA 110+50McKINNEY ST 101+50 TO 119+00
PROJECT LAYOUT
McKINNEY STREETN MAYHI
LL ROADS MAYHI
LL ROADLOT 4
E McKINNEY STREET
3918-3920
MICHAEL L ORINGDERFF
LESLIE A &
EX. R.O.W
EX. R.O.W
EX. R.O.W
CV-4
N = 7127635.39
E = 2400929.96
DEG = 1° 05' 28.85"
L = 328.34'
= 3° 35' 00.00" LT
R = 5,250.00'
T = 164.22'
CURVE 3 (CV-3)
CV-5
CV-3
CV-6
N = 7127416.80
E = 2401400.90
DEG = 3° 30' 02.71"
L = 323.74'
R = 1,636.67'
T = 162.40'
= 11° 20' 00.00" LT
CURVE 4 (CV-4)
N = 7127279.07
E = 2401971.72
DEG = 0° 38' 11.83"
PI STA = 112+04.53
L = 104.72'
= 0° 40' 00.00" RT
T = 52.36'
R = 9,000.00'
CURVE 5 (CV-5)
N = 7127057.59
E = 2402844.97
DEG = 0° 29' 59.69"
L = 846.81'
= 4° 14' 00.00" RT
T = 423.60'
R = 11,461.16'
CURVE 6 (CV-6)
192.57'
S 65° 06' 05.00" E
372.44'S 76° 26' 05.00" E
372.44'
S 76° 26' 05.00" E
424.94'
S 75° 46' 05.00" E
E: 2400925.52
N: 7127177.35
PC CV-5 111+52.17
E: 2401024.22
N: 7127142.35
PT CV-5 112+56.89
E: 2401423.89
N: 7126998.01
PC CV-6 116+81.83
E: 2401558.77
N: 7127378.71
PT CV-4 107+79.73
E: 2401078.92
N: 7127566.25
PT CV-3 102+63.42
EX. R.O.W
EX. R.O.W
ELEV. 585.34
PK NAIL SET
CONTROL POINT #33
ELEV. 586.24
"X" CUT SET
CONTROL POINT #32
E: 2402040.57
N: 7127261.61
STA 222+65.23 MAYHILL ROAD
STA 112+75.57 McKINNEY STREET=
E: 2401253.59
N: 7127485.17
PC CV-4 104+55.99
R.O.WEX. MATCHLINE STA 119+00REFERENCE ONLY
PI STA = 100+99.25
PI STA = 106+17.86
PI STA = 121+05.24
DONE BY OTHERS TO STA 119+50
CONTRACT, BEGIN WORK TO BE
STA 106+00 END WORK THIS
McKINNEY STREET
POINT
CONTROL POINTS
ELEV.NORTHING EASTING DESCRIPTION
586.24327127426.28 2401248.06
585.34337127178.02 2401056.72 PK NAIL SET
"X" CUT SET
CITY OF DENTON - McKINNEY STREET PHASE TWO1:80
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CHC03.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CHC03.dgn1:804:37:37 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
20 40 60 80
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
PARKING AREA
PBX
PBX
PBX
48" PECAN
DBL. 4"/15" HACKBERRY
6" HACKBERRY
21" CEDAR
8" HACKBERRY
DBL. 15"/24" PECAN24" PECAN27" PECANDBL. 18" ELM
15" PECAN
TRI 12" PECAN
30" PECAN
DBL. 8" TREEDBL. 8"/15" TREE
S
S
586.97
5/8" IRS W/RANDOM
35
585.195/8" IRS W/RANDOM34
LOT 151 (PT)
LOT 162, 163, 164 (OLD DCAD 1P, 1P2, 1R), AC LOT 166 LOT 167
LOT 151 (PT)
LOT 168LOT 161
BAYLOR UNIVERSITY
4663 E McKINNEY STREET
MEMORIAL BAPTIST CHURCH OF DENTON
4673 E McKINNEY STREET
MEMORIAL BAPTIST CHURCH OF DENTON
4683 E McKINNEY STREET
SAYR RESOURCES INC
BCI REAL ESTATE VENTURES,LP
5001 E McKINNEY STREET
BARBARA McDONALD COBB
DOC # 99-R0026679 EASEMENT
20' PUBLIC UTILITY
VOL. 5039, PG. 01056
EASEMENTCONSTRUCTION
20' TEMPORARY
VOL. 5039, PG. 01056
EASEMENT
20' PUBLIC UTILITY
VOL. 5039, PG. 01056
EASEMENT
8' PUBLIC UTILITY DOC
# 99-R0
0
7
7
3
0
9EASEMENT
2
0' PUBLI
C UTI
LI
TY
STREET
4515 E McKINNEY
GLADYS F STOUT
KENNETH L &
128+00
124+00123+00 125+00 127+00126+00122+00
119+00 121+00120+00 PT 125+28.65CONCRETE
PBX
E
E
36" TREE
36" PECAN
2" TREE
36" PECAN
2" TREE 587.02
5/8" IRS W/RANDOM
36
136+00
135+00
137+00
138+00
134+00
130+00
129+00
131+00 133+00132+00
128+00 PC 129+61.61LOT 169
LOT 151 (PT)
LOT 1R4
LOT 150
LOT 1
5043 E McKINNEY STREET
CHELA DARLINE McDONALD
BCI REAL ESTATE VENTURES,LP
5101 E McKINNEY STREET
DENTON ISD
5090 E McKINNEY STREET
EDIBERTO A RODRIGUEZ
E McKINNEY STREET
KIM Y PHAM
CAB. H, PG. 62
20' UTILITY EASEMENT
CAB. E, PG. 330
4' SIDEWALK EASEMENT
5MATCHLINE STA 128+00McKINNEY ST 119+00 TO 138+00
PROJECT LAYOUT
EX. R.O.W
CV-6
E: 2403246.76
N: 7126923.42
PT CV-6 125+28.65
MATCHLINE STA 128+00MATCHLINE STA 138+00EX. R.O.W
EX. R.O.W
EX. R.O.W
McKINNEY STREET
McKINNEY STREET
E: 2403657.43
N: 7126923.42
PC CV-7 129+61.61
432.96'
S 71° 32' 05.00" E
432.96'S 71° 32' 05.00" E
ELEV. 585.19
5/8" IRS RANDOM CAP
CONTROL POINT #34
ELEV. 586.97
5/8" IRS RANDOM CAP
CONTROL POINT #35
ELEV. 587.02
5/8" IRS RANDOM CAP
CONTROL POINT #36
EX. R.O.W
EX. R.O.W
EX. R.O.W
CURVE 6 (CV-6)
CURVE 7 (CV-7)
CV-7
PI STA = 121+05.24
N = 7127057.59
E = 2402844.97
= 4° 14' 00.00" RT
DEG = 0° 29' 59.69"
T = 423.60'
L = 846.81'
R = 11,461.16'
PI STA = 134+96.12
N = 7126786.29
E = 2403657.43
= 9° 48' 00.00" RT
DEG = 0° 55' 00.24"
T = 535.81'
L = 1,069.01'
R = 6,250.00'RYAN WAYCARPENTER ROADCARPENTERMATCHLINE STA 119+00END WORK TO BE DONE BY OTHERS
BEGIN WORK THIS CONTRACT
STA 119+50
E: 2403521.17
N: 7126831.79
CL CARPENTER ROAD
STA 128+17.95 McKINNEY STREET
POINT
CONTROL POINTS
ELEV.NORTHING EASTING DESCRIPTION
585.19347127037.38 2402752.25
586.97357126888.98 2403487.69 5/8" IRS RANDOM CAP
5/8" IRS RANDOM CAP
587.02367126624.81 2404189.92 5/8" IRS RANDOM CAP
CITY OF DENTON - McKINNEY STREET PHASE TWO1:80
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CHC04.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CHC04.dgn1:804:37:39 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
20 40 60 80
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
V
E
ES S
592.87
5/8" IRS W/RANDOM
37
LOT 1R4
LOT 1
LOT 147BLOT 1, BLOCK A LOT 1, BLOCK B
5101 E McKINNEY STREET
DENTON ISD
E McKINNEY STREET
KIM Y PHAM E McKINNEY STREET
KIM Y PHAM
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
E McKINNEY STREET
ATMOS ENERGY CORP
CAB. E, PG. 330
4' SIDEWALK EASEMENT
CAB. H, PG. 62
16' UTILITY EASEMENT
CAB. H, PG. 62
20' UTILITY EASEMENT CAB. H,
P
G.
6
2
1
6'
U
TI
LI
T
Y
E
AS
E
ME
NT
CAB. E, PG. 60
16' UTILITY EASEMENT
CAB. E, PG. 330
4' SIDEWALK EASEMENT
139+00138+00 140+00 148+00147+00146+00142+00141+00 143+00 145+00144+00 PT 140+30.62CONCRETE E
S
S
S
582.48X CUT SET38
S
148+00 149+00
151+00150+00
158+00
157+00
153+00
152+00
154+00
156+00
155+00
PC 152+46.66 PT 156+32.66LOT 147B
LOT 1
LOT 1
LOT 147A
E McKINNEY STREET
ATMOS ENERGY CORP
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
E McKINNEY STREET
ATMOS ENERGY CORP
CAB. E, PG. 6016' UTILITY EASEMENT CAB. E, PG. 60
16' UTILITY EASEMENT
K
OR
NU
P
AUL
& WE
N
T
S
AI
L
OT
1
08
6MATCHLINE STA 148+00McKINNEY ST 138+00 TO 158+00
PROJECT LAYOUT
McKINNEY STREETCV-7
EX. R.O.W
MATCHLINE STA 138+00MATCHLINE STA 148+00
E: 2404637.59
N: 7126923.42
PT CV-7 140+30.62
1216.03'
S 61° 44' 05.00" E
1216.03'S 61° 44' 05.00" E
EX. R.O.W
EX. R.O.W
EX. R.O.W
EX. R.O.W
EX. R.O.W
EX. R.O.W
ELEV. 592.87
5/8" IRS RANDOM CAP
CONTROL POINT #37
ELEV. 582.48
"X" CUT SET
CONTROL POINT #38
CURVE 8 (CV-8)
PI STA = 154+39.66
N = 7125695.37
E = 2405879.01
= 9° 39' 00.00" RT
DEG = 2° 30' 00.00"
T = 193.46'
R = 2,291.83'
CURVE 7 (CV-7)
PI STA = 134+96.12
N = 7126786.29
E = 2403657.43
= 9° 48' 00.00" RT
DEG = 0° 55' 00.24"
T = 535.81'
L = 1,069.01'
R = 6,250.00'
L = 386.00'
CV-8
MATCHLINE STA 158+00McKINNEY STREETS FORK ROAD
E: 2405708.62
N: 7126923.42
PC CV-8 152+46.66
804.20'S 52° 05' 05.00" E
EX. R.O.WWAYGLENNGARY
E: 2406031.64
N: 7125576.49
PT CV-8 156+32.66
E: 2404591.45
N: 7126387.40
CL GLENNGARY WAY
STA 139+78.36 McKINNEY STREET
E: 2405512.03
N: 7125892.69
CL S FORK ROAD
STA 150+23.45 McKINNEY STREET
POINT
CONTROL POINTS
ELEV.NORTHING EASTING DESCRIPTION
592.87377126294.73 2404863.34
582.48387125923.85 2405527.26 "X" CUT SET
5/8" IRS RANDOM CAP
CITY OF DENTON - McKINNEY STREET PHASE TWO1:80
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CHC05.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CHC05.dgn1:804:37:41 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
20 40 60 80
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
585.97
PK NAIL SET
39
594.115/8" IRS W/RANDOM40
DD
LOT 147A
LOT 143, 144
LOT 146
L
OT 108
E McKINNEY STREET
ATMOS ENERGY CORP
E McKINNEY STREET & TRINITY ROAD
THE WOODLANDS ON McKINNEY STREET LLC
E McKINNEY STREET
ATMOS ENERGY CORP
K
OR
N
U
P
A
UL
& WE
N TS
AI
LOT 145
E McKINNEY STREET & TRINITY ROAD
THE WOODLANDS ON McKINNEY STREET LLC
V
OL. 990, P
G.640
15'
UTILIT
Y E
ASE
ME
NT
K
O
R
N
U
PA
UL
& WE
N TS
AI
159+00158+00 160+00 162+00161+00 163+00 165+00164+00 166+00 167+00
PC 164+36.86S
S
S
S
587.065/8" IRS W/RANDOM41
D D
177+00
176+00175+00171+00170+00 172+00 174+00173+00169+00168+00167+00 PT 168+00.19 PC 175+86.79LOT 146
LOT 145 LOT 143, 144
LOT 146
LOT 143, 144
E McKINNEY STREET & TRINITY ROAD
THE WOODLANDS ON McKINNEY STREET LLC
E McKINNEY STREET
ATMOS ENERGY CORP
E McKINNEY STREET & TRINITY ROAD
THE WOODLANDS ON McKINNEY STREET LLC
E McKINNEY STREET
ATMOS ENERGY CORP
E McKINNEY STREET & GRISSOM ROAD
YES COMPANIES KEY LLC
E McKINNEY STREET & TRINITY ROAD
THE WOODLANDS ON McKINNEY STREET LLC
VOL. XX, PG. XX
25' UTILITY EASEMENT
VOL. XX, PG. XX
EASEMENT
30' TEMPORARY CONSTRUCTION PG. 351
VOL. 695,
EASEMENT
16' UTILITY
PG. XX
VOL. XX,
EASEMENT
16' UTILITY
VOL. XX, PG. XX
UTILITY EASEMENT
VARIABLE WIDTH
VOL. 1637, PG. 131
EASEMENT
16' SANITARY SEWER
7
E: 2399330.32N: 7127799.78PC CV-2 STA 93+74.59
MATCHLINE STA 167+00MATCHLINE STA 158+00
E: 2406666.09
N: 7125082.32
PC CV-9 164+36.86
804.20'
S 52° 05' 05.00" EELEV. 585.97
PK NAIL SET
CONTROL POINT #39
PI STA = 166+18.53
N = 7124970.64
E = 2406809.45
= 3° 38' 00.00" LT
DEG = 1° 00' 00.00"
T = 181.73'
R = 5,729.58'MATCHLINE STA 167+00EX. R.O.W
EX. R.O.W EX. R.O.W
EX. R.O.W
EX. R.O.W
L = 363.33'
ELEV. 594.11
5/8" IRS RANDOM CAP
CONTROL POINT #40
ELEV. 585.97
5/8" IRS RANDOM CAP
CONTROL POINT #41
E: 2405985.98
N: 7125110.80
PT CV-9 168+00.19
McKINNEY STREET
McKINNEY STREET ORR ROAD786.60'
S 55° 43' 05.00" E
CV-9
CURVE 9 (CV-9)
CV-9
McKINNEY ST 158+00 TO END
PROJECT LAYOUT
POINT
CONTROL POINTS
ELEV.NORTHING EASTING DESCRIPTION
585.97397125464.03 2406245.03
594.11407124928.76 2406771.04 5/8" IRS RANDOM CAP
PK NAIL SET
585.97417124586.09 2407437.90 5/8" IRS RANDOM CAP
CITY OF DENTON - McKINNEY STREET PHASE TWO1:80
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TCP00.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TCP00.dgn1:804:37:44 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
8
PHASE ONE
SEQUENCE OF CONSTRUCTION
PHASE TWO
SEQUENCE OF CONSTRUCTIONSEQUENCE OF CONSTRUCTION GENERAL NOTES
OF CONSTRUCTION NOTES
TRAFFIC CONTROL SEQUENCE
FACILITATE EARLY OPENING TO TRAFFIC.
(MINIMUM 3200 PSI COMPRESSIVE STRENGTH AND 450 PSI FLEXURAL STRENGTH IN 24 HR.) TO
MANAGER. SCHOOL DRIVEWAYS ARE TO BE CONSTRUCTED WITH HIGH EARLY STRENGTH CONCRETE
SCHOOL IS OUT OF SESSION FOR THE SUMMER OR ON WEEKENDS AS APPROVED BY CITY PROJECT
INTERSECTION AND THE BUS DRIVEWAY AT STATION 135+88.67 TO TAKE PLACE ONLY WHEN
9. IN ORDER TO LESSEN IMPACT TO SCHOOL TRAFFIC, CONSTRUCTION OF RYAN WAY
8. CONTRACTOR SHALL MAINTAIN POSITIVE DRAINAGE DURING ALL PHASES OF CONSTRUCTION.
7. SCHOOL ZONE FLASHERS SHALL BE OPERATIONAL DURING ALL PHASES OF CONSTRUCTION.
CONSTRUCTION.
6. VERIFY THE LOCATION OF ALL EXISTING UTILITIES PRIOR TO THE START OF ANY PHASE OF
PHASES OF CONSTRUCTION.
5. EROSION CONTROL DEVICES SHALL BE PROPERLY INSTALLED AND MAINTAINED DURING ALL
PROVIDED AT ALL TIMES.
4. SIDEWALKS AND/OR CLEAR PASSAGE WAYS THAT ARE CLEARLY IDENTIFIABLE SHALL BE
TO SETTING UP FOR EACH PHASE OF CONSTRUCTION.
EDITION OF THE TEXAS MUTCD AND SUBMIT THEM TO THE CITY OF DENTON FOR APPROVAL PRIOR
BARRICADES, MARKINGS, BUTTONS, AND DETOUR ROUTES IN ACCORDANCE WITH THE LATEST
3. THE CONTRACTOR SHALL PREPARE DETAILED TRAFFIC CONTROL PLANS SHOWING ALL SIGNS,
MAINTAINED AT ALL TIMES UNLESS OTHERWISE AUTHORIZED IN WRITING BY THE CITY.
MAINTAINED) ON McKINNEY STREET. ACCESS TO ALL SIDE STREETS AND DRIVEWAYS SHALL BE
PAVEMENT WIDTH INCLUDING DETOUR PAVEMENT, ONE LANE IN EACH DIRECTION SHALL BE
2. DURING ALL PHASES OF CONSTRUCTION A MINIMIUM OF TWO LANES OF TRAFFIC (20' MIN.
ADJUSTMENTS SHALL BE MADE.
SCHEDULE OR SEQUENCE BECOMES UNWORKABLE OR UNSATISFACTORY AS WORK PROCEEDS,
BE SUBMITTED TO THE CITY FOR APPROVAL PRIOR TO THE START OF CONSTRUCTION. IF THE
PROJECT DURING CONSTRUCTION. THE SCHEDULE & SEQUENCING OF CONSTRUCTION PLAN SHALL
THAT SHALL CAUSE MINIMUM INTERFERENCE WITH TRAFFIC ALONG, ACROSS AND ADJACENT TO THE
A CONSTRUCTION SCHEDULE, SEQUENCE OF CONSTRUCTION, AND DETAILED TRAFFIC CONTROL PLAN
OF BIDS ONLY. PRIOR TO THE START OF WORK, THE CONTRACTOR SHALL DEVELOP, IN DETAIL,
1. THE SEQUENCE OF CONSTRUCTION SHOWN IN THE PLANS IS FOR PREPARATION AND COMPARISON
PLACE THE PHASE TWO TEMPORARY MARKINGS AND SIGNS AND SHIFT TRAFFIC.10.
DRIVEWAY CONNECTIONS; AND TRANSITIONS.
CONSTRUCT THE SOUTH HALF (EAST BOUND LANES) OF McKINNEY STREET; ALL STREET AND 9F.
CONSTRUCT PROPOSED LIGHTING FOUNDATIONS AND INSTALL CONDUIT AND LIGHTING POLES.9E.
CONNECTIONS ALONG McKINNEY STREET BETWEEN MAYHILL ROAD AND STA 143+00.
TO EXISTING MAINS, FIRE HYDRANTS, WATER SERVICE LINES, METERS AND SERVICE
CONSTRUCT THE 16-INCH WATER MAIN ON THE SOUTH SIDE OF THE ROAD, ALL CONNECTIONS 9D.
CONNECTIONS ALONG McKINNEY STREET BETWEEN LOOP 288 AND MAYHILL ROAD.
TO EXISTING MAINS, FIRE HYDRANTS, WATER SERVICE LINES, METERS AND SERVICE
CONSTRUCT THE 12-INCH WATER MAIN ON THE SOUTH SIDE OF THE ROAD, ALL CONNECTIONS 9C.
ALL TIMES DURING CONSTRUCTION.
OF McKINNEY STREET. MAKE NECESSARY PIPE CONNECTIONS TO MAINTAIN POSITIVE DRAINAGE AT
CONSTRUCT STORMWATER MAINS, BOX CULVERTS, LATERALS, AND INLETS ON THE SOUTH HALF 9B.
WASTEWATER LINE JUST EAST OF MAYHILL ROAD.
CONSTRUCT A 10-INCH WASTEWATER LINE IN THE SAME TRENCH AS THE EXISTING 8" 9A.
CONSTRUCT THE FOLLOWING, CONTRACTOR TO DETERMINE ORDER OF CONSTRUCTION:9.
PLACE TEMPORARY PAVEMENT MARKINGS.8.
WIDTH).
CONSTRUCT TEMPORARY PAVEMENT ON NORTH SIDE OF McKINNEY STREET (20' MIN. PAVEMENT 7.
CONTRACTOR TO ADJUST SIGNALS ACCORDINGLY PER PHASE ONE.6.
THE NEW SYSTEM IS IN OPERATION.
TRAFFIC SIGNAL HEADS. THE EXISTING TRAFFIC SIGNAL SYSTEM SHALL NOT BE REMOVED UNTIL
THE CONTRACTOR SHALL INSTALL TEMPORARY TRAFFIC SIGNAL CABLE TO THE PEDESTRIAN AND 5.
ARMS, HEADS, AND EQUIPMENT FOR TRAFFIC CONTROL DURING PHASE ONE.
CONSTRUCT PROPOSED TRAFFIC SIGNAL FOUNDATIONS AND INSTALL THE SIGNAL POLES, MAST 4.
INSTALL EQUIPMENT FOR TRAFFIC CONTROL DURING PHASE ONE.3.
AGREEMENT HAS BEEN REACHED WITH THE PROPERTY OWNER TO CLOSE ACCESS TO THEIR PROPERTY.
2. MAINTAIN ACCESS TO ALL PROPERTIES THROUGH THIS PHASE OF CONSTRUCTION UNLESS AN
EDITION OF THE TEXAS MUTCD AND TXDOT STANDARD DETAILS.
INSTALL PHASE ONE TRAFFIC CONTROL SIGNS AND DEVICES IN ACCORDANCE WITH THE LATEST 1.
OPEN ALL LANES TO TRAFFIC.11.
REMOVE THE TEMPORARY MARKINGS AND SIGNS. PLACE THE PERMANENT MARKINGS AND SIGNS.10.
DRIVEWAY CONNECTIONS; AND TRANSITIONS.
CONSTRUCT THE NORTH HALF (WEST BOUND LANES) OF McKINNEY STREET; ALL STREET AND 9E.
CONSTRUCT PROPOSED LIGHTING FOUNDATIONS AND INSTALL CONDUIT AND LIGHTING POLES.9D.
CONNECTIONS ALONG McKINNEY STREET BETWEEN MAYHILL ROAD AND STA 143+00.
TO EXISTING MAINS, FIRE HYDRANTS, WATER SERVICE LINES, METERS AND SERVICE
CONSTRUCT THE 16-INCH WATER MAIN ON THE NORTH SIDE OF THE ROAD, ALL CONNECTIONS 9C.
CONNECTIONS ALONG McKINNEY STREET BETWEEN LOOP 288 AND MAYHILL ROAD.
TO EXISTING MAINS, FIRE HYDRANTS, WATER SERVICE LINES, METERS AND SERVICE
CONSTRUCT THE 20-INCH WATER MAIN ON THE NORTH SIDE OF THE ROAD, ALL CONNECTIONS 9B.
DURING CONSTRUCTION.
OF McKINNEY STREET. MAKE NECESSARY PIPE CONNECTIONS TO MAINTAIN POSITIVE DRAINAGE
CONSTRUCT STORMWATER MAINS, BOX CULVERTS, LATERALS, AND INLETS ON THE NORTH SIDE 9A.
CONSTRUCT THE FOLLOWING, CONTRACTOR TO DETERMINE ORDER OF CONSTRUCTION:9.
PLACE TEMPORARY PAVEMENT MARKINGS.8.
WIDTH).
CONSTRUCT TEMPORARY PAVEMENT ON SOUTH SIDE OF McKINNEY STREET (20' MIN. PAVEMENT 7.
CONTRACTOR TO ADJUST SIGNALS ACCORDINGLY PER PHASE TWO.6.
REMOVED UNTIL THE NEW SYSTEM IS IN OPERATION.
TRAFFIC SIGNAL HEADS FOR PHASE TWO. THE EXISTING TRAFFIC SIGNAL SYSTEM SHALL NOT BE
THE CONTRACTOR SHALL ADJUST NEW TRAFFIC SIGNAL CABLE TO THE PEDESTRIAN AND 5.
INSTALL EQUIPMENT FOR TRAFFIC CONTROL DURING PHASE TWO.4.
AGREEMENT HAS BEEN REACHED WITH THE PROPERTY OWNER TO CLOSE ACCESS TO THEIR PROPERTY.
MAINTAIN ACCESS TO ALL PROPERTIES THROUGH THIS PHASE OF CONSTRUCTION UNLESS AN 3.
EDITION OF THE TEXAS MUTCD AND TXDOT STANDARD DETAILS.
INSTALL PHASE TWO TRAFFIC CONTROL SIGNS AND DEVICES IN ACCORDANCE WITH THE LATEST 2.
ASPHALT PAVEMENT ON THE SOUTH SIDE OF McKINNEY STREET.
1. TRAFFIC WILL TRAVEL ON THE NEWLY CONSTRUCTED EAST BOUND LANES AND TEMPORARY
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TCP00A.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TCP00A.dgn1:404:37:46 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837NTS
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL 2019
SEP
CONSTRUCTION - TYP. SECTIONS
TRAFFIC CONTROL SEQUENCE OF
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
LC
GROUND
EXISTING
100' EX. R.O.W
TYP.
12"
TYP.
6"
LANE
11'
LANE
10'
(TYP.)
GUTTER
CURB &
STANDARD
SIDEWALK
LANE
11'
LANE
10'
3" ASPHALT BASE (TYPE B)
6" ASPHALT BASE (TYPE B)
EXISTING GROUNDR.O.W.EX. R.O.W.EX. SUBGRADE (36 LB/SY/LIFT)
12" LIME STABILIZED
57' B-B
2% MAX
1.5% TYP.
6:1 MAX
3:1 MAX
4:1 TYP.
2'
5.5'
6:1 MAX
1.5% TYP.
6:1 MAX
1.5% TYP.
3:1 MAX
4:1 TYP.
& GUTTER (TYP.)
STANDARD CURB
2% MAX
1.5% TYP.
FUTURE
6'
7'-9.5'
BIKE/PED PATH
12' FUTURE
5'
3'-5.5'
LC
GROUND
EXISTING
100' EX. R.O.W
LANE
10'
LANE
11'
SIDEWALK
LANE
10'
LANE
11'
3" ASPHALT BASE (TYPE B)6" ASPHALT BASE (TYPE B)
EXISTING GROUNDR.O.W.EX. R.O.W.EX. SUBGRADE (36 LB/SY/LIFT)
12" LIME STABILIZED
6:1 MAX
1.5% TYP.
3:1 MAX
4:1 TYP.
& GUTTER (TYP.)
STANDARD CURB
2% MAX1.5% TYP.
FUTURE
6'
7'-9.5'
3'-5.5'
CONSTRUCTION PHASE ONE TYPICAL SECTION
PARTIAL
6'
BARRIER FOR CONSTRUCTION
PAVEMENT
EXISTING
PAVEMENT
ASPHALT
TEMPORARY
CONSTRUCTION PHASE TWO TYPICAL SECTION
3'
PARTIAL
6'
CONSTRUCTION
BARRIER FOR
PAVEMENT
EXISTING
BARRELS TO PROTECT CURB
AND CURB TO ALLOW FOR
EDGE OF TRAVEL LANE
3' GAP BETWEEN
LANE
LEFT TURN
TWO-WAY
LANE
LEFT TURN
TWO-WAY
9
SIDEWALK
REINF.CONCRETE
FUTURE 4"
SIDEWALK
REINF.CONCRETE
FUTURE 4"
SIDEWALK
CONCRETE
REINF.
FUTURE 6"
THE BID ITEM "TRAFFIC CONTROL".
FOR TRAFFIC CONTROL TO BE SUBSIDIARY TO
2.ALL TEMPORARY PAVEMENT MARKINGS REQUIRED
UPON COMPLETION OF CONSTRUCTION PHASE TWO.
1.3" ASPHALT SURFACE COURSE TO BE PLACED
NOTES:
CITY OF DENTON - McKINNEY STREET PHASE TWO1:80
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TCP01.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TCP01.dgn1:804:37:53 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
20 40 60 80
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
NOTES:
PERMANENT TRANSITION PAVEMENT.
THE SOUTH SIDE/EAST-BOUND LANES AND
WEST-BOUND LANES ON THE NORTH SIDE AND BUILD
PHASE 2: CONTRACTOR TO SHIFT TRAFFIC TO NEW
TRANSITION PAVEMENT.
NORTH SIDE/WEST-BOUND LANES AND TEMPORARY
SOUTH SIDE OF EXISTING PAVEMENT AND BUILD
PHASE 1: CONTRACTOR TO SHIFT TRAFFIC TO
SUGGESTED SEQUENCE OF CONSTRUCTION:
BARRIER FOR CONSTRUCTION
PHASE 1 TRAFFIC
CONSTRUCTION
PHASE 1 TEMP. PAVEMENT
PAVEMENT CONSTRUCTION
PHASE 1
LEGEND:
TRAFFIC FLOW
PHASE 1 SIGN
2019
SEP
OF CONSTRUCTION - PHASE ONE
TRAFFIC CONTROL SEQUENCE
CHANNELIZING DEVICE
INSPECTOR.
AND AS APPROVED BY CITY OF DENTON
BARRIERS BETWEEN PHASES, PER TEXAS MUTCD,
3. CONTRACTOR TO PROVIDE ADEQUATE TRAFFIC
ALL TIMES.
2. CONTRACTOR TO MAINTAIN LOCAL ACCESS AT
CONSTRUCTION ZONE SIGNING.
1. CONTRACTOR TO FOLLOW TEXAS MUTCD FOR
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
PARKING AREA
PA
RKING AR
EA
PARKING AREA
E
E
S
S
S
S ONLYONLYONLYONLYONLYONLYONLY
LOOP 288
7-ELEVEN INC
101 N LOOP 288
DENNIS J KOOP
3612 E McKINNEY STREET
McKINNEY BUILDING, LP
3612 E McKINNEY STREET
McKINNEY BUILDING, LP
3600 E McKINNEY STREET
McKINNEY BUILDING, LP
LOT 24A
LOT 1
LOT 1
LOT 1
LOT 1
LOT 1R
3621 E McKINNEY STREET
DENNIS J KOOP
3601 E McKINNEY STREET
PIONEER ORT INVESTMENTS INC
LOT 44
101 S LOOP 288
INVESTMENT COMPANY
SEJ ASSET MANAGEMENT &
88+00
89+00
91+0090+0086+0082+00 83+00 85+0084+00 87+00 10072+0010073+0010074+0010075+00 PC 86+94.15 PT 90+20.18V
V
V
PARKING AREA
E
PARKING AREA
S
S
S S
PARKING AREA
E McKINNEY STREET
CCD-RLG DENTON I LP
3701 E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
3730 E McKINNEY STREET
LISA FONG LEUNG
100 N LOOP 288
100 NORTH LOOP 288, LLC
101 S LOOP 288
DNB INVESTMENTS LTD
LOOP 288
7-ELEVEN INC
LOT 1
LOT 1
LOT 1
LOT 1
LOT 1
LOT 41
LOT 24A
LOT 1
101 S LOOP 288
INVESTMENT COMPANY
SEJ ASSET MANAGEMENT &
191 DUCHESS DRIVE
JBJ/CALDER FUND VII JOINT VENTURE
92+00
100+0099+00 101+0098+0094+0093+00 95+00 97+0096+00
PC 93+74.59 PT 94+85.56 PC 99+35.08D DONLYMcKINNEY STREETCARDINAL DRIVEMATCHLINE STA 91+50N LOOP 288S LOOP 288MATCHLINE STA 91+5010
McKINNEY STREET
MATCHLINE STA 101+5020'20'DRIVEDUCHESS48x24
G20-2
ROAD WORK
END
3612 E McKINNEY STREET
McKINNEY BUILDING, LP
LOT 2R
LOT 1
E McKINNEY STREET
CCD-RLG DENTON I LP
LOT 1
191 DUCHESS DRIVE
VII JOINT VENTURE
JBJ/CALDER FUND
100' TAPER
TEMPORARY PAVEMENT
CONSTRUCT
STRIPE
PAINTED
YELLOW
4" DOUBLE
CONSTRUCTION
BARRIER FOR
LANES
BOUND
EAST
CONSTRUCT
EAST BOUND LANES
CONSTRUCT
100' STORAGE
CL McKINNEY STREET
CL McKINNEY STREET
CONSTRUCTION
BARRIER FOR
MEDIAN AND STRIPING
REMOVE EXISTING
STRIPING
EXISTING
REMOVE
320'320'320'(TYP.)640'(TYP.)320'320'
(TYP.)
320'
640'
(TYP.)
TRAFFIC CONTROL
FOR PH. 1 LOOP 288
SEE SHEET 14
CHANNELIZING DEVICE
48x48
CW9-2TR
RIGHT
MERGE
LANE ENDS
LEFT
MERGE
LANE ENDS
48x48
CW9-2TL
48x42
R20-3T
STATE LAW
SIGNS
WARNING
OBEY
48x48
CW20-1
AHEAD
WORK
ROAD
NEXT X MILES
ROAD WORK
BEGIN
STATE
CITY
ADDRESS
NAME
CONTRACTOR
48x30
G20-6T
36X24
G20-5T
WORK ZONE
END
48x24
G20-2bT
CLOSED
SIDEWALK
24x12
R9-9
36x36
R20-5aTP
36x36
R20-5T
DOUBLE
FINES
TRAFFIC
ZONE
WORK
BEGIN
PRESENT
ARE
WORKERS
WHEN
36x24
G20-5aP
NEXT X MILES
ROAD WORK
BEGIN
STATE
CITY
ADDRESS
NAME
CONTRACTOR
48x30
G20-6T
36X24
G20-5T
48x48
CW20-1
AHEAD
WORK
ROAD
48x42
R20-3T
STATE LAW
SIGNS
WARNING
OBEY
48x24
G20-2
ROAD WORK
END
WORK ZONE
END
48x24
G20-2bT
DEVICE
CHANNELIZING
36x36
R20-5aTP
36x36
R20-5T
DOUBLE
FINES
TRAFFIC
ZONE
WORK
BEGIN
PRESENT
ARE
WORKERS
WHEN
36x24
G20-5aP
PAINTED STRIPE
4" DOUBLE YELLOW
CITY OF DENTON - McKINNEY STREET PHASE TWO1:80
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TCP02.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TCP02.dgn1:804:37:55 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
20 40 60 80
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
NOTES:
PERMANENT TRANSITION PAVEMENT.
THE SOUTH SIDE/EAST-BOUND LANES AND
WEST-BOUND LANES ON THE NORTH SIDE AND BUILD
PHASE 2: CONTRACTOR TO SHIFT TRAFFIC TO NEW
TRANSITION PAVEMENT.
NORTH SIDE/WEST-BOUND LANES AND TEMPORARY
SOUTH SIDE OF EXISTING PAVEMENT AND BUILD
PHASE 1: CONTRACTOR TO SHIFT TRAFFIC TO
SUGGESTED SEQUENCE OF CONSTRUCTION:
BARRIER FOR CONSTRUCTION
PHASE 1 TRAFFIC
CONSTRUCTION
PHASE 1 TEMP. PAVEMENT
PAVEMENT CONSTRUCTION
PHASE 1
LEGEND:
TRAFFIC FLOW
PHASE 1 SIGN
2019
SEP
OF CONSTRUCTION - PHASE ONE
TRAFFIC CONTROL SEQUENCE
CHANNELIZING DEVICE
INSPECTOR.
AND AS APPROVED BY CITY OF DENTON
BARRIERS BETWEEN PHASES, PER TEXAS MUTCD,
3. CONTRACTOR TO PROVIDE ADEQUATE TRAFFIC
ALL TIMES.
2. CONTRACTOR TO MAINTAIN LOCAL ACCESS AT
CONSTRUCTION ZONE SIGNING.
1. CONTRACTOR TO FOLLOW TEXAS MUTCD FOR
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
V
PARKING AREA
PARKING AREA
PARKING AREA
PARKING AREA
CONCRETE
E
PARKING AREA
PARKING AREA
PARKING AREA
24" HACKBERRY
DBL. 12" TREE
24" TREE
TRI 6" TREE
DBL. 10" HACKBERRY 18" ELM
6" TREE
TRI 4" TREE
QUAD 6" ELM
DBL. 8" HACKBERRY 6" ELM DBL. 6"/12" HACKBERRY DBL. 6" HACKBERRY DBL. 8" HACKBERRY
4" ELM
6" ELM 15" HACKBERRY10" CEDAR
DBL. 10" TREEDBL. 12" HACKBERRYDBL. 6" ELM
10" TREE
S S
586.24
X CUT SET
32
E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
LOT 27
E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
LOT 29 LOT 38
3801 E McKINNEY STREET
ANGEL & GRISELDA ENRIQUEZ
LOT 1R
3919/3921 E McKINNEY STREET
NSA PROPERTY HOLDINGS, LLC
LOT 1
191 DUCHESS DRIVE
JBJ/CALDER FUND VII JOINT VENTURE
LOT 1
3910 E McKINNEY STREET
SCOTTIE ADAMS
LOT 2
3912 E McKINNEY STREET
DUNCAN STREET COMMERCIAL LLC
LOT 3
3916 E McKINNEY STREET
EDWARD D & SHARYL K DIELEMAN
STREET
3918-3920 E McKINNEY
ORINGDERFF
LESLIE A & MICHAEL L
D
D
110+00
106+00
105+00 107+00
109+00
108+00104+00
103+00
102+00
PT 102+63.42 PC 104+55.99 PT 107+79.73PARKING AREA
PARKING AREA
CONCRETE
CONCRETE
E E
PARKING AREA
S
S
S
D
D
S
S
LOT 4
STREET
3918-3920 E McKINNEY
ORINGDERFF
LESLIE A & MICHAEL L
LOT 3
3923 E McKINNEY STREET
3919 McKINNEY, LLC
LOT 152
STREET
McKINNEY
4001 E
DENTON
CITY OF
LOT 153
E McKINNEY STREET
CITY OF DENTON
LOT 154
4301 E McKINNEY STREET
CITY OF DENTON
LOT 159
4393 E McKINNEY STREET
KENNETH L & GLADYS F STOUT
LOT 161
LOT 5R1
3922 E McKINNEY STREET
GOEL VENTURES ONE, LLC
LOT 151 (PT)
E McKINNEY STREET (200' STRIP)
BCI REAL ESTATE VENTURES, LP
STREET
McKINNEY
4515 E
STOUT
& GLADYS F
KENNETH L
D D
112+00111+00 115+00114+00 116+00 118+00117+00 119+00113+00
2
24+00223+0
0222+00221+00 PC 111+52.17 PC 116+81.83 PT 112+56.8911MATCHLINE STA 110+50MATCHLINE STA 101+50MATCHLINE STA 110+50McKINNEY STREET
McKINNEY STREETN MAYHI
LL ROADS MAYHI
LL ROADLOT 4
E McKINNEY STREET
3918-3920
MICHAEL L ORINGDERFF
LESLIE A &MATCHLINE STA 119+00TRAFFIC CONTROL
FOR PH. 1 MAYHILL RD
SEE SHEET 15
200' ASPHALT TRANSITION
PAINTED STRIPE
4" DOUBLE YELLOW
EAST BOUND LANES
CONSTRUCT20'PAVEMENT
TEMPORARY
CONSTRUCT
STRIPING
MATCH EXISTING
DONE BY OTHERS TO STA 119+50
CONTRACT, BEGIN WORK TO BE
STA 106+00 END WORK THIS
CL McKINNEY STREET
CONSTRUCTION
BARRIER FOR
CONSTRUCTED BY OTHERS
STATION 119+50 TO BE
STREET STATION 106+00 TO
INTERSECTION AND McKINNEY
MAYHILL ROAD/McKINNEY STREET
TRANSITION
200' ASPHALT
STRIPING
MATCH EXISTING
REFERENCE ONLY
REFERENCE ONLY
48x48
CW1-4R
48x48
CW1-4L
CITY OF DENTON - McKINNEY STREET PHASE TWO1:80
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TCP03.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TCP03.dgn1:804:37:58 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
20 40 60 80
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
NOTES:
PERMANENT TRANSITION PAVEMENT.
THE SOUTH SIDE/EAST-BOUND LANES AND
WEST-BOUND LANES ON THE NORTH SIDE AND BUILD
PHASE 2: CONTRACTOR TO SHIFT TRAFFIC TO NEW
TRANSITION PAVEMENT.
NORTH SIDE/WEST-BOUND LANES AND TEMPORARY
SOUTH SIDE OF EXISTING PAVEMENT AND BUILD
PHASE 1: CONTRACTOR TO SHIFT TRAFFIC TO
SUGGESTED SEQUENCE OF CONSTRUCTION:
BARRIER FOR CONSTRUCTION
PHASE 1 TRAFFIC
CONSTRUCTION
PHASE 1 TEMP. PAVEMENT
PAVEMENT CONSTRUCTION
PHASE 1
LEGEND:
TRAFFIC FLOW
PHASE 1 SIGN
2019
SEP
OF CONSTRUCTION - PHASE ONE
TRAFFIC CONTROL SEQUENCE
CHANNELIZING DEVICE
INSPECTOR.
AND AS APPROVED BY CITY OF DENTON
BARRIERS BETWEEN PHASES, PER TEXAS MUTCD,
3. CONTRACTOR TO PROVIDE ADEQUATE TRAFFIC
ALL TIMES.
2. CONTRACTOR TO MAINTAIN LOCAL ACCESS AT
CONSTRUCTION ZONE SIGNING.
1. CONTRACTOR TO FOLLOW TEXAS MUTCD FOR
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
PARKING AREA
PBX
PBX
PBX
48" PECAN
DBL. 4"/15" HACKBERRY
6" HACKBERRY
21" CEDAR
8" HACKBERRY
DBL. 15"/24" PECAN24" PECAN27" PECANDBL. 18" ELM
15" PECAN
TRI 12" PECAN
30" PECAN
DBL. 8" TREEDBL. 8"/15" TREE
S
S
BAYLOR UNIVERSITY
4663 E McKINNEY STREET
MEMORIAL BAPTIST CHURCH OF DENTON
4673 E McKINNEY STREET
MEMORIAL BAPTIST CHURCH OF DENTON
4683 E McKINNEY STREET
SAYR RESOURCES INC
BCI REAL ESTATE VENTURES,LP
5001 E McKINNEY STREET
BARBARA McDONALD COBB
LOT 151 (PT)
LOT 162, 163, 164 (OLD DCAD 1P, 1P2, 1R), AC
LOT 166 LOT 167
LOT 151 (PT)
LOT 168
LOT 151 (PT)
BAYLOR UNIVERSITY
STREETMcKINNEY 4515 E STOUT& GLADYS F KENNETH L
D
128+00
124+00123+00 125+00 127+00126+00122+00
119+00 121+00120+00 PT 125+28.65D
D
CONCRETE
PBX
E
E
36" TREE
36" PECAN
2" TREE
36" PECAN
2" TREE
136+00
135+00
137+00
138+00
134+00
130+00
129+00
131+00 133+00132+00
128+00 PC 129+61.61LOT 169
LOT 151 (PT)
LOT 1R4
LOT 150
LOT 1
5043 E McKINNEY STREET
CHELA DARLINE McDONALD
BCI REAL ESTATE VENTURES,LP
5101 E McKINNEY STREET
DENTON ISD
5090 E McKINNEY STREET
EDIBERTO A RODRIGUEZ
E McKINNEY STREET
KIM Y PHAM
12MATCHLINE STA 128+00MATCHLINE STA 128+00MATCHLINE STA 138+00McKINNEY STREET
McKINNEY STREETRYAN WAYCARPENTER ROADCARPENTERMATCHLINE STA 119+00TEMPORARY PAVEMENT
CONSTRUCT
CL McKINNEY STREET
PAINTED STRIPE
4" DOUBLE YELLOW
20'20'EAST BOUND LANES
CONSTRUCT
EAST BOUND LANES
CONSTRUCT
CONSTRUCTION
BARRIER FOR
CONSTRUCTION
BARRIER FOR
CL McKINNEY STREET
PAVEMENT
TEMPORARY
CONSTRUCT
PAINTED STRIPE
4" DOUBLE YELLOW 320'320'(TYP.)320'640'(TYP.)16
TRAFFIC CONTROL
FOR PH. 1 CARPENTER RD
SEE SHEET
16
TRAFFIC CONTROL
AND CARPENTER RD
FOR PH. 1 RYAN WY
SEE SHEET
END WORK TO BE DONE BY OTHERS
BEGIN WORK THIS CONTRACT
STA 119+50
TRANSITION
200' ASPHALT
NEXT X MILES
ROAD WORK
BEGIN
STATE
CITY
ADDRESS
NAME
CONTRACTOR
48x30
G20-6T
36X24
G20-5T
48x48
CW20-1
AHEAD
WORK
ROAD
36x36
R20-5aTP
36x36
R20-5T
DOUBLE
FINES
TRAFFIC
ZONE
WORK
BEGIN
PRESENT
ARE
WORKERS
WHEN
36x24
G20-5aP
48x42
R20-3T
STATE LAW
SIGNS
WARNING
OBEY
WORK ZONE
END
48x24
G20-2bT
48x24
G20-2
ROAD WORK
END
CITY OF DENTON - McKINNEY STREET PHASE TWO1:80
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TCP04.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TCP04.dgn1:804:38:01 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
20 40 60 80
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
NOTES:
PERMANENT TRANSITION PAVEMENT.
THE SOUTH SIDE/EAST-BOUND LANES AND
WEST-BOUND LANES ON THE NORTH SIDE AND BUILD
PHASE 2: CONTRACTOR TO SHIFT TRAFFIC TO NEW
TRANSITION PAVEMENT.
NORTH SIDE/WEST-BOUND LANES AND TEMPORARY
SOUTH SIDE OF EXISTING PAVEMENT AND BUILD
PHASE 1: CONTRACTOR TO SHIFT TRAFFIC TO
SUGGESTED SEQUENCE OF CONSTRUCTION:
BARRIER FOR CONSTRUCTION
PHASE 1 TRAFFIC
CONSTRUCTION
PHASE 1 TEMP. PAVEMENT
PAVEMENT CONSTRUCTION
PHASE 1
LEGEND:
TRAFFIC FLOW
PHASE 1 SIGN
2019
SEP
OF CONSTRUCTION - PHASE ONE
TRAFFIC CONTROL SEQUENCE
CHANNELIZING DEVICE
INSPECTOR.
AND AS APPROVED BY CITY OF DENTON
BARRIERS BETWEEN PHASES, PER TEXAS MUTCD,
3. CONTRACTOR TO PROVIDE ADEQUATE TRAFFIC
ALL TIMES.
2. CONTRACTOR TO MAINTAIN LOCAL ACCESS AT
CONSTRUCTION ZONE SIGNING.
1. CONTRACTOR TO FOLLOW TEXAS MUTCD FOR
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
V
E
ES S
LOT 1R4
LOT 1
LOT 147BLOT 1, BLOCK A LOT 1, BLOCK B
5101 E McKINNEY STREET
DENTON ISD
E McKINNEY STREET
KIM Y PHAM E McKINNEY STREET
KIM Y PHAM
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
E McKINNEY STREET
ATMOS ENERGY CORP
139+00138+00 140+00 148+00147+00146+00142+00141+00 143+00 145+00144+00 PT 140+30.62CONCRETE E
S
S
S
S
148+00 149+00
151+00150+00
158+00
157+00
153+00
152+00
154+00
156+00
155+00
PC 152+46.66 PT 156+32.66LOT 147B
LOT 1
LOT 1
LOT 147A
E McKINNEY STREET
ATMOS ENERGY CORP
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
E McKINNEY STREET
ATMOS ENERGY CORP
K
OR
NU
P
AUL
& WE
N
T
S
AI
L
OT
1
08
6+00 7+00 8+00 5+006+007+004+00
2+00
3+00
2+00 3+00
13MATCHLINE STA 148+00McKINNEY STREET
MATCHLINE STA 138+00MATCHLINE STA 148+00McKINNEY STREET
TEMPORARY PAVEMENT
CONSTRUCT
TEMPORARY PAVEMENT
CONSTRUCT
CL McKINNEY STREET
CL McKINNEY STREET
PAINTED STRIPE
4" DOUBLE YELLOW
PAINTED STRIPE
4" DOUBLE YELLOW
EAST BOUND LANES
CONSTRUCT
EAST BOUND LANES
CONSTRUCT
CONSTRUCTION
BARRIER FOR
CONSTRUCTION
BARRIER FOR20'20'100' TAPERROADS FORKPAINTED STRIPE
4" SINGLE WHITE
100' TAPER320'320'
(TYP.
)320'320'320'(TYP.)320'640'(TYP.)640'
(TYP.
)
640'
(TYP.)
320
'(TYP.)
320'CLOSED
SIDEWALK
24x12
R9-9
48x48
CW20-1
AHEAD
WORK
ROAD36x36
R20-5aTP
36x36
R20-5T
DOUBLE
FINES
TRAFFIC
ZONE
WORK
BEGIN
PRESENT
ARE
WORKERS
WHEN
36x24
G20-5aP
48x42
R20-3T
STATE LAW
SIGNS
WARNING
OBEY
WORK ZONE
END
48x24
G20-2bT
48x24
G20-2
ROAD WORK
END
WORK ZONE
END
48x24
G20-2bT
48x24
G20-2
ROAD WORK
END
WORK ZONE
END
48x24
G20-2bT
48x24
G20-2
ROAD WORK
END
48x48
CW20-1
AHEAD
WORK
ROAD
NEXT X MILES
ROAD WORK
BEGIN
STATE
CITY
ADDRESS
NAME
CONTRACTOR
48x30
G20-6T
36X24
G20-5T
NEXT X MILES
ROAD WORK
BEGIN
STATE
CITY
ADDRESS
NAME
CONTRACTOR
48x30
G20-6T
36X24
G20-5T
NEXT X MILES
ROAD WORK
BEGIN
STATE
CITY
ADDRESS
NAME
CONTRACTOR
48x30
G20-6T
36X24
G20-5T
36x36
R20-5aTP
36x36
R20-5T
DOUBLE
FINES
TRAFFIC
ZONE
WORK
BEGIN
PRESENT
ARE
WORKERS
WHEN
36x24
G20-5aP
48x42
R20-3T
STATE LAW
SIGNS
WARNING
OBEY
48x48
CW20-1
AHEAD
WORK
ROADWAYGLENNGARY
48x48
CW1-4L
48x48
CW1-6aT
CITY OF DENTON - McKINNEY STREET PHASE TWO1:80
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TCP05.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TCP05.dgn1:804:38:03 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
20 40 60 80
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
NOTES:
PERMANENT TRANSITION PAVEMENT.
THE SOUTH SIDE/EAST-BOUND LANES AND
WEST-BOUND LANES ON THE NORTH SIDE AND BUILD
PHASE 2: CONTRACTOR TO SHIFT TRAFFIC TO NEW
TRANSITION PAVEMENT.
NORTH SIDE/WEST-BOUND LANES AND TEMPORARY
SOUTH SIDE OF EXISTING PAVEMENT AND BUILD
PHASE 1: CONTRACTOR TO SHIFT TRAFFIC TO
SUGGESTED SEQUENCE OF CONSTRUCTION:
BARRIER FOR CONSTRUCTION
PHASE 2 TRAFFIC
CONSTRUCTION
PHASE 2 TEMP. PAVEMENT
PAVEMENT CONSTRUCTION
PHASE 2
LEGEND:
TRAFFIC FLOW
PHASE 2 SIGN
2019
SEP
OF CONSTRUCTION - PHASE ONE
TRAFFIC CONTROL SEQUENCE
INSPECTOR.
AND AS APPROVED BY CITY OF DENTON
BARRIERS BETWEEN PHASES, PER TEXAS MUTCD,
3. CONTRACTOR TO PROVIDE ADEQUATE TRAFFIC
ALL TIMES.
2. CONTRACTOR TO MAINTAIN LOCAL ACCESS AT
CONSTRUCTION ZONE SIGNING.
1. CONTRACTOR TO FOLLOW TEXAS MUTCD FOR
CHANNELIZING DEVICE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN ISV
PA
RKING AR
EA
PARKING AREA
E
PARKIN
G AREAS
S
S
S ONLYONLYONLYONLYONLYONLYONLY
ONLY
101 S LOO
P 288D
NB I
NVESTM
EN
TS LTDLOOP 288
7-ELEVEN INC
LOOP 2887-ELEV
EN I
NC3612 E McKINNEY STREET
McKINNEY BUILDING, LP
3612 E McKINNEY STREET
McKINNEY BUILDING, LP
LOT 41LOT 24A
LOT 1 LOT 24A
LOT 1
LOT 1
LOT 13621 E McKINNEY STREET
DENNIS J KOOP
101 S LOOP 288
INVESTMENT COMPANY
SEJ ASSET MANAGEMENT & 10
1 S LOOP 288I
NVESTM
EN
T COM
PAN
YSEJ ASSET M
ANA
GEMENT
&
88+00
89+00
91+0090+0086+0085+00
92+0093+0087+00 10071+0010072+0010073+0010074+0010075+0010076+00 PC 86+94.15 PT 90+20.18ONLYMcKINNEY STREET N LOOP 288S LOOP 28814
CL McKINNEY STREET
20'3612 E McKINNEY STREET
McKINNEY BUILDING, LP
LOT 2R
101 N LOOP 288
DENNIS J KOOP
LOT 1
101 S LOO
P 288D
NB I
NVESTM
EN
TS LTDLOT 41320'320'(TYP.)320'320'320'(TYP.)320'640'(TYP.)640'(TYP.)10
TRAFFIC CONTROL
FOR PH. 1 McKINNEY ST
THROUGHSEE SHEETS 13
TRAFFIC CONTROL
LOOP 288 PHASE ONE
NEXT X MILES
ROAD WORK
BEGIN
STATE
CITY
ADDRESS
NAME
CONTRACTOR
48x30
G20-6T
36X24
G20-5T
48x48
CW20-1
AHEAD
WORK
ROAD
36x36
R20-5aTP
36x36
R20-5T
DOUBLE
FINES
TRAFFIC
ZONE
WORK
BEGIN
PRESENT
ARE
WORKERS
WHEN
36x24
G20-5aP
48x42
R20-3T
STATE LAW
SIGNS
WARNING
OBEY
WORK ZONE
END
48x24
G20-2bT
48x24
G20-2
ROAD WORK
END
NEXT X MILES
ROAD WORK
BEGIN
STATE
CITY
ADDRESS
NAME
CONTRACTOR
48x30
G20-6T
36X24
G20-5T
48x48
CW20-1
AHEAD
WORK
ROAD
36x36
R20-5aTP
36x36
R20-5T
DOUBLE
FINES
TRAFFIC
ZONE
WORK
BEGIN
PRESENT
ARE
WORKERS
WHEN
36x24
G20-5aP
48x42
R20-3T
STATE LAW
SIGNS
WARNING
OBEY
WORK ZONE
END
48x24
G20-2bT
48x24
G20-2
ROAD WORK
END
CITY OF DENTON - McKINNEY STREET PHASE TWO1:80
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TCP06.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TCP06.dgn1:804:38:06 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
20 40 60 80
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
NOTES:
PERMANENT TRANSITION PAVEMENT.
THE SOUTH SIDE/EAST-BOUND LANES AND
WEST-BOUND LANES ON THE NORTH SIDE AND BUILD
PHASE 2: CONTRACTOR TO SHIFT TRAFFIC TO NEW
TRANSITION PAVEMENT.
NORTH SIDE/WEST-BOUND LANES AND TEMPORARY
SOUTH SIDE OF EXISTING PAVEMENT AND BUILD
PHASE 1: CONTRACTOR TO SHIFT TRAFFIC TO
SUGGESTED SEQUENCE OF CONSTRUCTION:
BARRIER FOR CONSTRUCTION
PHASE 2 TRAFFIC
CONSTRUCTION
PHASE 2 TEMP. PAVEMENT
PAVEMENT CONSTRUCTION
PHASE 2
LEGEND:
TRAFFIC FLOW
PHASE 2 SIGN
2019
SEP
OF CONSTRUCTION - PHASE ONE
TRAFFIC CONTROL SEQUENCE
INSPECTOR.
AND AS APPROVED BY CITY OF DENTON
BARRIERS BETWEEN PHASES, PER TEXAS MUTCD,
3. CONTRACTOR TO PROVIDE ADEQUATE TRAFFIC
ALL TIMES.
2. CONTRACTOR TO MAINTAIN LOCAL ACCESS AT
CONSTRUCTION ZONE SIGNING.
1. CONTRACTOR TO FOLLOW TEXAS MUTCD FOR
CHANNELIZING DEVICE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
V
PARKING AREA PARKING AREA
PARKING AREA
CONCRETE
CONCRETE
CONCRETE
E
E
PARKING AREA
PARKING AREA
PARKING AREA
PARKING AREA
S
S
S
D
D
S
D
S
LOT 1R
3919/3921 E McKINNEY STREET
NSA PROPERTY HOLDINGS, LLC
LOT 3
3916 E McKINNEY STREET
EDWARD D & SHARYL K DIELEMAN
LOT 4
STREET
3918-3920 E McKINNEY
ORINGDERFF
LESLIE A & MICHAEL L
LOT 3
3923 E McKINNEY STREET
3919 McKINNEY, LLC
LOT 152
STREET
McKINNEY
4001 E
DENTON
CITY OF
LOT 153
E McKINNEY STREET
CITY OF DENTON
LOT 154
4301 E McKINNEY STREET
CITY OF DENTON
LOT 5R1
3922 E McKINNEY STREET
GOEL VENTURES ONE, LLC
LOT 151 (PT)
E McKINNEY STREET (200' STRIP)
BCI REAL ESTATE VENTURES, LP
D D
112+00111+00 115+00114+00110+00109+00 116+00 117+00113+00224+00223+0
0222+00221+00 PC 111+52.17 PC 116+81.83 PT 112+56.8915
McKINNEY STREET N MAYHI
LL ROADS MAYHI
LL ROAD320'320'
(TYP.
)320'320'320'
(TYP.)320'640'
(TYP.
)640'
(TYP.
)
10
TRAFFIC CONTROL
FOR PH. 1 McKINNEY ST
THROUGHSEE SHEETS 13
CONSTRUCTED BY OTHERS
STATION 119+50 TO BE
STREET STATION 106+00 TO
INTERSECTION AND McKINNEY
MAYHILL ROAD/McKINNEY STREET
REFERENCE ONLY
TRAFFIC CONTROL
MAYHILL PHASE ONE
NEXT X MILES
ROAD WORK
BEGIN
STATE
CITY
ADDRESS
NAME
CONTRACTOR
48x30
G20-6T
36X24
G20-5T
48x48
CW20-1
AHEAD
WORK
ROAD
36x36
R20-5aTP
36x36
R20-5T
DOUBLE
FINES
TRAFFIC
ZONE
WORK
BEGIN
PRESENT
ARE
WORKERS
WHEN
36x24
G20-5aP
48x42
R20-3T
STATE LAW
SIGNS
WARNING
OBEY
WORK ZONE
END
48x24
G20-2bT
48x24
G20-2
ROAD WORK
END
CLOSED
SIDEWALK
24x12
R9-9
CLOSED
SIDEWALK
24x12
R9-9
CLOSED
SIDEWALK
24x12
R9-9
CLOSED
SIDEWALK
24x12
R9-9
NEXT X MILES
ROAD WORK
BEGIN
STATE
CITY
ADDRESS
NAME
CONTRACTOR
48x30
G20-6T
36X24
G20-5T
48x48
CW20-1
AHEAD
WORK
ROAD
48x42
R20-3T
STATE LAW
SIGNS
WARNING
OBEY
36x36
R20-5aTP
36x36
R20-5T
DOUBLE
FINES
TRAFFIC
ZONE
WORK
BEGIN
PRESENT
ARE
WORKERS
WHEN
36x24
G20-5aP
WORK ZONE
END
48x24
G20-2bT
48x24
G20-2
ROAD WORK
END
CITY OF DENTON - McKINNEY STREET PHASE TWO1:80
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TCP07.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TCP07.dgn1:804:38:08 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
20 40 60 80
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
NOTES:
PERMANENT TRANSITION PAVEMENT.
THE SOUTH SIDE/EAST-BOUND LANES AND
WEST-BOUND LANES ON THE NORTH SIDE AND BUILD
PHASE 2: CONTRACTOR TO SHIFT TRAFFIC TO NEW
TRANSITION PAVEMENT.
NORTH SIDE/WEST-BOUND LANES AND TEMPORARY
SOUTH SIDE OF EXISTING PAVEMENT AND BUILD
PHASE 1: CONTRACTOR TO SHIFT TRAFFIC TO
SUGGESTED SEQUENCE OF CONSTRUCTION:
BARRIER FOR CONSTRUCTION
PHASE 1 TRAFFIC
CONSTRUCTION
PHASE 1 TEMP. PAVEMENT
PAVEMENT CONSTRUCTION
PHASE 1
LEGEND:
TRAFFIC FLOW
PHASE 1 SIGN
2019
SEP
OF CONSTRUCTION - PHASE ONE
TRAFFIC CONTROL SEQUENCE
CHANNELIZING DEVICE
INSPECTOR.
AND AS APPROVED BY CITY OF DENTON
BARRIERS BETWEEN PHASES, PER TEXAS MUTCD,
3. CONTRACTOR TO PROVIDE ADEQUATE TRAFFIC
ALL TIMES.
2. CONTRACTOR TO MAINTAIN LOCAL ACCESS AT
CONSTRUCTION ZONE SIGNING.
1. CONTRACTOR TO FOLLOW TEXAS MUTCD FOR
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
D
D
CONCRETE
PBX
PBX
E
36" TREE
36" PECAN
2" TREE
36" PECAN
2" TREE
48" PECAN
DBL. 4"/15" HACKBERRY
6" HACKBERRY
21" CEDAR
8" HACKBERRY
DBL. 15"/24" PECAN
24" PECAN
S
130+00
129+00
131+00 133+00132+00
128+00
125+00
127+00
126+00
PT 125+28.65 PC 129+61.6120' PUBLIC UTILITY
EASEMENT
DOC # 99-R0077309
LOT 167
LOT 151 (PT)
LOT 168
LOT 169
LOT 151 (PT)
LOT 1R4
LOT 150
4683 E McKINNEY STREETSAYR RESOURCES INC
BCI REAL ESTATE VENTURES,LP
5001 E McKINNEY STREETBARBARA McDONALD COBB
5043 E McKINNEY STREET
CHELA DARLINE McDONALD
BCI REAL ESTATE VENTURES,LP
5101 E McKINNEY STREET
DENTON ISD
5090 E McKINNEY STREET
EDIBERTO A RODRIGUEZ
16
McKINNEY STREET RYAN WAYCARPENTER ROAD20'LOT 1R4
5101 E McKINNEY STREET
DENTON ISD
LOT 168
McKINNEY STREET5001 E
COBB
McDONALDBARBARA
LOT 167
4683 E McKINNEY STREETSAYR RESOURCES INC
TEMPORARY PAVEMENT
CONSTRUCT
EAST BOUND LANES
CONSTRUCT CONSTRUCTION
BARRIER FOR
CL McKINNEY STREET 320'320'
(TYP.
)320'
3
2
0'
3
2
0'
(TYP.
)
3
2
0'6
4
0'
(TYP.
)640'(TYP.)ONE TRAFFIC CONTROL
AND RYAN WAY PHASE
CARPENTER ROAD
10
TRAFFIC CONTROL
FOR PH. 1 McKINNEY ST
THROUGHSEE SHEETS 13
NEXT X MILES
ROAD WORK
BEGIN
STATE
CITY
ADDRESS
NAME
CONTRACTOR
48x30
G20-6T
36X24
G20-5T
36x36
R20-5aTP
36x36
R20-5T
DOUBLE
FINES
TRAFFIC
ZONE
WORK
BEGIN
PRESENT
ARE
WORKERS
WHEN
36x24
G20-5aP
WORK ZONE
END
48x24
G20-2bT
48x24
G20-2
ROAD WORK
END
48x24
G20-2
ROAD WORK
END
WORK ZONE
END
48x24
G20-2bT
36x36
R20-5aTP
36x36
R20-5T
DOUBLE
FINES
TRAFFIC
ZONE
WORK
BEGIN
PRESENT
ARE
WORKERS
WHEN
36x24
G20-5aP
48x42
R20-3T
STATE LAW
SIGNS
WARNING
OBEY
48x42
R20-3T
STATE LAW
SIGNS
WARNING
OBEY
48x48
CW20-1
AHEAD
WORK
ROAD
48x48
CW20-1
AHEAD
WORK
ROAD
NEXT X MILES
ROAD WORK
BEGIN
STATE
CITY
ADDRESS
NAME
CONTRACTOR
48x30
G20-6T
36X24
G20-5T
CITY OF DENTON - McKINNEY STREET PHASE TWO1:80
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TCP08.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TCP08.dgn1:804:38:11 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
20 40 60 80
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
NOTES:
PERMANENT TRANSITION PAVEMENT.
THE SOUTH SIDE/EAST-BOUND LANES AND
WEST-BOUND LANES ON THE NORTH SIDE AND BUILD
PHASE 2: CONTRACTOR TO SHIFT TRAFFIC TO NEW
TRANSITION PAVEMENT.
NORTH SIDE/WEST-BOUND LANES AND TEMPORARY
SOUTH SIDE OF EXISTING PAVEMENT AND BUILD
PHASE 1: CONTRACTOR TO SHIFT TRAFFIC TO
SUGGESTED SEQUENCE OF CONSTRUCTION:
BARRIER FOR CONSTRUCTION
PHASE 2 TRAFFIC
CONSTRUCTION
PHASE 2 TEMP. PAVEMENT
PAVEMENT CONSTRUCTION
PHASE 2
LEGEND:
TRAFFIC FLOW
PHASE 2 SIGN
2019
SEP
OF CONSTRUCTION - PHASE TWO
TRAFFIC CONTROL SEQUENCE
INSPECTOR.
AND AS APPROVED BY CITY OF DENTON
BARRIERS BETWEEN PHASES, PER TEXAS MUTCD,
3. CONTRACTOR TO PROVIDE ADEQUATE TRAFFIC
ALL TIMES.
2. CONTRACTOR TO MAINTAIN LOCAL ACCESS AT
CONSTRUCTION ZONE SIGNING.
1. CONTRACTOR TO FOLLOW TEXAS MUTCD FOR
CHANNELIZING DEVICE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
PARKING AREA
PA
RKING AR
EA
PARKING AREA
E
E
S
S
S
S ONLYONLYONLYONLYONLYONLYONLY
LOOP 288
7-ELEVEN INC
101 N LOOP 288
DENNIS J KOOP
3612 E McKINNEY STREET
McKINNEY BUILDING, LP
3612 E McKINNEY STREET
McKINNEY BUILDING, LP
3600 E McKINNEY STREET
McKINNEY BUILDING, LP
LOT 24A
LOT 1
LOT 1
LOT 1
LOT 1R
3621 E McKINNEY STREET
DENNIS J KOOP
3601 E McKINNEY STREET
PIONEER ORT INVESTMENTS INC
LOT 44
101 S LOOP 288
INVESTMENT COMPANY
SEJ ASSET MANAGEMENT &
88+00
89+00
91+0090+0086+0082+00 83+00 85+0084+00 87+00 10072+0010073+0010074+0010075+00 PC 86+94.15 PT 90+20.18V
V
PARKING AREA
E
PARKING AREA
S
S
S S
PARKING AREA
E McKINNEY STREET
CCD-RLG DENTON I LP
3701 E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
3730 E McKINNEY STREET
LISA FONG LEUNG
100 N LOOP 288
100 NORTH LOOP 288, LLC
101 S LOOP 288
DNB INVESTMENTS LTD
LOOP 288
7-ELEVEN INC
LOT 1
LOT 1
LOT 1
LOT 1
LOT 41
LOT 24A
LOT 1
101 S LOOP 288
INVESTMENT COMPANY
SEJ ASSET MANAGEMENT &
191 DUCHESS DRIVE
JBJ/CALDER FUND VII JOINT VENTURE
92+00
100+0099+00 101+0098+0094+0093+00 95+00 97+0096+00
PC 93+74.59 PT 94+85.56 PC 99+35.08D
D
D
D
McKINNEY STREETCARDINAL DRIVEMATCHLINE STA 91+50N LOOP 288S LOOP 288MATCHLINE STA 91+5017
McKINNEY STREET
MATCHLINE STA 101+5020'20'DRIVEDUCHESS3612 E McKINNEY STREET
McKINNEY BUILDING, LP
LOT 2R
LOT 1
E McKINNEY STREET
CCD-RLG DENTON I LP
LOT 1
191 DUCHESS DRIVE
VII JOINT VENTURE
JBJ/CALDER FUND
ONLY
30x36
R3-5R
ONLY
30x36
R3-5L
101 N LOOP 288
DENNIS J KOOP
LOT 1
320'320'
(TYP.)
320'
640'
(TYP.)320'320'(TYP.)320'640'(TYP.)100' TAPER
TEMPORARY PAVEMENT
CONSTRUCT
PAINTED STRIPE
4" DOUBLE YELLOW
LANES
BOUND
EAST
CONSTRUCT
CURB
BARRELS TO PROTECT
CURB TO ALLOW FOR
OF TRAVEL LANE AND
3' GAP BETWEEN EDGE
WEST BOUND LANES
CONSTRUCT
100' STORAGE
WORD
EXISTING
REMOVE
STRIPE
PAINTED
YELLOW
4" DOUBLE
CL McKINNEY STREET
CL McKINNEY STREET
CONSTRUCTION
BARRIER FOR
ARROW
REMOVE EXISTING
TRAFFIC CONTROL
FOR PH. 2 LOOP 288
SEE SHEET 21
CURB
BARRELS TO PROTECT
CURB TO ALLOW FOR
OF TRAVEL LANE AND
3' GAP BETWEEN EDGE
DEVICE
CHANNELIZING
DEVICE
CHANNELIZING
1 2'
TRAFFIC CONTROL
TO BE BUILT IN PHASES FOR
THIS PORTION OF PAVEMENT
CLOSED
SIDEWALK
24x12
R9-9
NEXT X MILES
ROAD WORK
BEGIN
STATE
CITY
ADDRESS
NAME
CONTRACTOR
48x30
G20-6T
36X24
G20-5T
48x48
CW20-1
AHEAD
WORK
ROAD
48x42
R20-3T
STATE LAW
SIGNS
WARNING
OBEY
WORK ZONE
END
48x24
G20-2bT
48x24
G20-2
ROAD WORK
END
36x36
R20-5aTP
36x36
R20-5T DOUBLE
FINES
TRAFFIC
ZONE
WORK
BEGIN
PRESENT
ARE
WORKERS
WHEN
36x24
G20-5aP
36x36
R20-5aTP
36x36
R20-5T DOUBLE
FINES
TRAFFIC
ZONE
WORK
BEGIN
PRESENT
ARE
WORKERS
WHEN
36x24
G20-5aP
48x48
CW20-1
AHEAD
WORK
ROAD
48x24
G20-2
ROAD WORK
END
WORK ZONE
END
48x24
G20-2bT
48x42
R20-3T
STATE LAW
SIGNS
WARNING
OBEY
NEXT X MILES
ROAD WORK
BEGIN
36X24
G20-5T
RIGHT
MERGE
TRAFFIC
THRU
36x36
W4-7
RIGHT
MERGE
TRAFFIC
THRU
36x36
W4-7
STATE
CITY
ADDRESS
NAME
CONTRACTOR
48x30
G20-6T
CITY OF DENTON - McKINNEY STREET PHASE TWO1:80
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TCP09.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TCP09.dgn1:804:38:13 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
20 40 60 80
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
NOTES:
PERMANENT TRANSITION PAVEMENT.
THE SOUTH SIDE/EAST-BOUND LANES AND
WEST-BOUND LANES ON THE NORTH SIDE AND BUILD
PHASE 2: CONTRACTOR TO SHIFT TRAFFIC TO NEW
TRANSITION PAVEMENT.
NORTH SIDE/WEST-BOUND LANES AND TEMPORARY
SOUTH SIDE OF EXISTING PAVEMENT AND BUILD
PHASE 1: CONTRACTOR TO SHIFT TRAFFIC TO
SUGGESTED SEQUENCE OF CONSTRUCTION:
BARRIER FOR CONSTRUCTION
PHASE 2 TRAFFIC
CONSTRUCTION
PHASE 2 TEMP. PAVEMENT
PAVEMENT CONSTRUCTION
PHASE 2
LEGEND:
TRAFFIC FLOW
PHASE 2 SIGN
2019
SEP
OF CONSTRUCTION - PHASE TWO
TRAFFIC CONTROL SEQUENCE
INSPECTOR.
AND AS APPROVED BY CITY OF DENTON
BARRIERS BETWEEN PHASES, PER TEXAS MUTCD,
3. CONTRACTOR TO PROVIDE ADEQUATE TRAFFIC
ALL TIMES.
2. CONTRACTOR TO MAINTAIN LOCAL ACCESS AT
CONSTRUCTION ZONE SIGNING.
1. CONTRACTOR TO FOLLOW TEXAS MUTCD FOR
CHANNELIZING DEVICE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
V
PARKING AREA
PARKING AREA
PARKING AREA
PARKING AREA
CONCRETE
E
PARKING AREA
PARKING AREA
PARKING AREA
24" HACKBERRY
DBL. 12" TREE
24" TREE
TRI 6" TREE
DBL. 10" HACKBERRY 18" ELM
6" TREE
TRI 4" TREE
QUAD 6" ELM
DBL. 8" HACKBERRY 6" ELM DBL. 6"/12" HACKBERRY DBL. 6" HACKBERRY DBL. 8" HACKBERRY
4" ELM
6" ELM 15" HACKBERRY10" CEDAR
DBL. 10" TREEDBL. 12" HACKBERRYDBL. 6" ELM
10" TREE
S S
586.24
X CUT SET
32ONLYE McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
LOT 27
E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
LOT 29 LOT 38
3801 E McKINNEY STREET
ANGEL & GRISELDA ENRIQUEZ
LOT 1R
3919/3921 E McKINNEY STREET
NSA PROPERTY HOLDINGS, LLC
LOT 1
191 DUCHESS DRIVE
JBJ/CALDER FUND VII JOINT VENTURE
LOT 1
3910 E McKINNEY STREET
SCOTTIE ADAMS
LOT 2
3912 E McKINNEY STREET
DUNCAN STREET COMMERCIAL LLC
LOT 3
3916 E McKINNEY STREET
EDWARD D & SHARYL K DIELEMAN
STREET
3918-3920 E McKINNEY
ORINGDERFF
LESLIE A & MICHAEL L
D
D
110+00
106+00
105+00 107+00
109+00
108+00104+00
103+00
102+00
PT 102+63.42 PC 104+55.99 PT 107+79.73PARKING AREA
PARKING AREA
CONCRETE
CONCRETE
E E
PARKING AREA
S
S
S
D
D
S
S
LOT 4
STREET
3918-3920 E McKINNEY
ORINGDERFF
LESLIE A & MICHAEL L
LOT 3
3923 E McKINNEY STREET
3919 McKINNEY, LLC
LOT 152
STREET
McKINNEY
4001 E
DENTON
CITY OF
LOT 153
E McKINNEY STREET
CITY OF DENTON
LOT 154
4301 E McKINNEY STREET
CITY OF DENTON
LOT 159
4393 E McKINNEY STREET
KENNETH L & GLADYS F STOUT
LOT 161
LOT 5R1
3922 E McKINNEY STREET
GOEL VENTURES ONE, LLC
LOT 151 (PT)
E McKINNEY STREET (200' STRIP)
BCI REAL ESTATE VENTURES, LP
STREET
McKINNEY
4515 E
STOUT
& GLADYS F
KENNETH L
D D
112+00111+00 115+00114+00 116+00 118+00117+00 119+00113+00
2
24+00223+0
0222+00221+00 PC 111+52.17 PC 116+81.83 PT 112+56.8918MATCHLINE STA 110+50MATCHLINE STA 101+50MATCHLINE STA 110+50McKINNEY STREET
McKINNEY STREETN MAYHI
LL ROADS MAYHI
LL ROADLOT 4
E McKINNEY STREET
3918-3920
MICHAEL L ORINGDERFF
LESLIE A &MATCHLINE STA 119+0020'200' ASPHALT TRANSITION
PAINTED STRIPE
4" DOUBLE YELLOW
WEST BOUND LANES
CONSTRUCT
PAVEMENT
TEMPORARY
CONSTRUCT
CL McKINNEY STREET
CONSTRUCTION
BARRIER FOR
TRAFFIC CONTROL
FOR PH. 2 MAYHILL RD
SEE SHEET 22
CURB
BARRELS TO PROTECT
CURB TO ALLOW FOR
OF TRAVEL LANE AND
3' GAP BETWEEN EDGE
DONE BY OTHERS TO STA 119+50
CONTRACT, BEGIN WORK TO BE
STA 106+00 END WORK THIS
STRIPING
MATCH EXISTING
CONSTRUCTED BY OTHERS
STATION 119+50 TO BE
STREET STATION 106+00 TO
INTERSECTION AND McKINNEY
MAYHILL ROAD/McKINNEY STREET
TRANSITION
200' ASPHALT
STRIPING
MATCH EXISTING
REFERENCE ONLY
REFERENCE ONLY
48x48
CW1-4L
48x48
CW1-4R
CITY OF DENTON - McKINNEY STREET PHASE TWO1:80
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TCP10.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TCP10.dgn1:804:38:16 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
20 40 60 80
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
NOTES:
PERMANENT TRANSITION PAVEMENT.
THE SOUTH SIDE/EAST-BOUND LANES AND
WEST-BOUND LANES ON THE NORTH SIDE AND BUILD
PHASE 2: CONTRACTOR TO SHIFT TRAFFIC TO NEW
TRANSITION PAVEMENT.
NORTH SIDE/WEST-BOUND LANES AND TEMPORARY
SOUTH SIDE OF EXISTING PAVEMENT AND BUILD
PHASE 1: CONTRACTOR TO SHIFT TRAFFIC TO
SUGGESTED SEQUENCE OF CONSTRUCTION:
BARRIER FOR CONSTRUCTION
PHASE 2 TRAFFIC
CONSTRUCTION
PHASE 2 TEMP. PAVEMENT
PAVEMENT CONSTRUCTION
PHASE 2
LEGEND:
TRAFFIC FLOW
PHASE 2 SIGN
2019
SEP
OF CONSTRUCTION - PHASE TWO
TRAFFIC CONTROL SEQUENCE
INSPECTOR.
AND AS APPROVED BY CITY OF DENTON
BARRIERS BETWEEN PHASES, PER TEXAS MUTCD,
3. CONTRACTOR TO PROVIDE ADEQUATE TRAFFIC
ALL TIMES.
2. CONTRACTOR TO MAINTAIN LOCAL ACCESS AT
CONSTRUCTION ZONE SIGNING.
1. CONTRACTOR TO FOLLOW TEXAS MUTCD FOR
CHANNELIZING DEVICE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
PARKING AREA
PBX
PBX
PBX
48" PECAN
DBL. 4"/15" HACKBERRY
6" HACKBERRY
21" CEDAR
8" HACKBERRY
DBL. 15"/24" PECAN24" PECAN27" PECANDBL. 18" ELM
15" PECAN
TRI 12" PECAN
30" PECAN
DBL. 8" TREEDBL. 8"/15" TREE
S
S
LOT 151 (PT)
LOT 162, 163, 164 (OLD DCAD 1P, 1P2, 1R), AC LOT 166 LOT 167
LOT 151 (PT)
LOT 168LOT 161
BAYLOR UNIVERSITY
4663 E McKINNEY STREET
MEMORIAL BAPTIST CHURCH OF DENTON
4673 E McKINNEY STREET
MEMORIAL BAPTIST CHURCH OF DENTON
4683 E McKINNEY STREET
SAYR RESOURCES INC
BCI REAL ESTATE VENTURES,LP
5001 E McKINNEY STREET
BARBARA McDONALD COBB
STREET
4515 E McKINNEY
GLADYS F STOUT
KENNETH L &
D
128+00
124+00123+00 125+00 127+00126+00122+00
119+00 121+00120+00 PT 125+28.65D
D
CONCRETE
PBX
E
E
36" TREE
36" PECAN
2" TREE
36" PECAN
2" TREE
136+00
135+00
137+00
138+00
134+00
130+00
129+00
131+00 133+00132+00
128+00 PC 129+61.61LOT 169
LOT 151 (PT)
LOT 1R4
LOT 150
LOT 1
5043 E McKINNEY STREET
CHELA DARLINE McDONALD
BCI REAL ESTATE VENTURES,LP
5101 E McKINNEY STREET
DENTON ISD
5090 E McKINNEY STREET
EDIBERTO A RODRIGUEZ
E McKINNEY STREET
KIM Y PHAM
19MATCHLINE STA 128+00MATCHLINE STA 128+00MATCHLINE STA 138+00McKINNEY STREET
McKINNEY STREETRYAN WAYCARPENTER ROADCARPENTERMATCHLINE STA 119+00CL McKINNEY STREET
PAINTED STRIPE
4" DOUBLE YELLOW
20'20'EAST BOUND LANES
CONSTRUCT
EAST BOUND LANES
CONSTRUCT
CONSTRUCTION
BARRIER FOR
CONSTRUCTION
BARRIER FOR
CL McKINNEY STREET320'320'(TYP.)320'640'(TYP.) CURB
BARRELS TO PROTECT
CURB TO ALLOW FOR
OF TRAVEL LANE AND
3' GAP BETWEEN EDGE
CURB
BARRELS TO PROTECT
CURB TO ALLOW FOR
OF TRAVEL LANE AND
3' GAP BETWEEN EDGE
PAINTED STRIPE
4" DOUBLE YELLOW
23
TRAFFIC CONTROL
FOR PH. 2 CARPENTER RD
SEE SHEET
23
TRAFFIC CONTROL
AND CARPENTER RD
FOR PH. 2 RYAN WY
SEE SHEET
END WORK TO BE DONE BY OTHERS
BEGIN WORK THIS CONTRACT
STA 119+50
TRANSITION
200' ASPHALT
NEXT X MILES
ROAD WORK
BEGIN
STATE
CITY
ADDRESS
NAME
CONTRACTOR
48x30
G20-6T
36X24
G20-5T
48x48
CW20-1
AHEAD
WORK
ROAD
36x36
R20-5aTP
36x36
R20-5T
DOUBLE
FINES
TRAFFIC
ZONE
WORK
BEGIN
PRESENT
ARE
WORKERS
WHEN
36x24
G20-5aP
48x42
R20-3T
STATE LAW
SIGNS
WARNING
OBEY
WORK ZONE
END
48x24
G20-2bT
48x24
G20-2
ROAD WORK
END
CITY OF DENTON - McKINNEY STREET PHASE TWO1:80
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TCP11.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TCP11.dgn1:804:38:18 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
20 40 60 80
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
NOTES:
PERMANENT TRANSITION PAVEMENT.
THE SOUTH SIDE/EAST-BOUND LANES AND
WEST-BOUND LANES ON THE NORTH SIDE AND BUILD
PHASE 2: CONTRACTOR TO SHIFT TRAFFIC TO NEW
TRANSITION PAVEMENT.
NORTH SIDE/WEST-BOUND LANES AND TEMPORARY
SOUTH SIDE OF EXISTING PAVEMENT AND BUILD
PHASE 1: CONTRACTOR TO SHIFT TRAFFIC TO
SUGGESTED SEQUENCE OF CONSTRUCTION:
BARRIER FOR CONSTRUCTION
PHASE 2 TRAFFIC
CONSTRUCTION
PHASE 2 TEMP. PAVEMENT
PAVEMENT CONSTRUCTION
PHASE 2
LEGEND:
TRAFFIC FLOW
PHASE 2 SIGN
2019
SEP
OF CONSTRUCTION - PHASE TWO
TRAFFIC CONTROL SEQUENCE
INSPECTOR.
AND AS APPROVED BY CITY OF DENTON
BARRIERS BETWEEN PHASES, PER TEXAS MUTCD,
3. CONTRACTOR TO PROVIDE ADEQUATE TRAFFIC
ALL TIMES.
2. CONTRACTOR TO MAINTAIN LOCAL ACCESS AT
CONSTRUCTION ZONE SIGNING.
1. CONTRACTOR TO FOLLOW TEXAS MUTCD FOR
CHANNELIZING DEVICE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
V
E
ES S
LOT 1R4
LOT 1
LOT 147BLOT 1, BLOCK A LOT 1, BLOCK B
5101 E McKINNEY STREET
DENTON ISD
E McKINNEY STREET
KIM Y PHAM E McKINNEY STREET
KIM Y PHAM
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
E McKINNEY STREET
ATMOS ENERGY CORP
139+00138+00 140+00 148+00147+00146+00142+00141+00 143+00 145+00144+00 PT 140+30.62CONCRETE E
S
S
S
S
148+00 149+00
151+00150+00
158+00
157+00
153+00
152+00
154+00
156+00
155+00
PC 152+46.66 PT 156+32.66LOT 147B
LOT 1
LOT 1
LOT 147A
E McKINNEY STREET
ATMOS ENERGY CORP
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
E McKINNEY STREET
ATMOS ENERGY CORP
K
OR
NU
P
AUL
& WE
N
T
S
AI
L
OT
1
08
6+00 7+00 8+00 9+005+006+007+004+00
2+00
3+00
2+00 3+00
20MATCHLINE STA 148+00McKINNEY STREET
MATCHLINE STA 138+00MATCHLINE STA 148+00McKINNEY STREET
CL McKINNEY STREET
CL McKINNEY STREET
PAINTED STRIPE
4" DOUBLE YELLOW
WEST BOUND LANES
CONSTRUCT
WEST BOUND LANES
CONSTRUCT
CONSTRUCTION
BARRIER FOR
CONSTRUCTION
BARRIER FOR20'20'100' TAPERROADS FORK100' TAPER
PAINTED STRIPE
4" SINGLE WHITE
PAINTED STRIPE
4" DOUBLE YELLOW
STRIPING
MATCH EXISTING
CURB
BARRELS TO PROTECT
CURB TO ALLOW FOR
OF TRAVEL LANE AND
3' GAP BETWEEN EDGE
CURB
BARRELS TO PROTECT
CURB TO ALLOW FOR
OF TRAVEL LANE AND
3' GAP BETWEEN EDGE 320'320'(TYP.)320'640'(TYP.)320'(TYP.)
320'
640'
(TYP.)
NEXT X MILES
ROAD WORK
BEGIN
STATE
CITY
ADDRESS
NAME
CONTRACTOR
48x30
G20-6T
36X24
G20-5T
36x36
R20-5aTP
36x36
R20-5T
DOUBLE
FINES
TRAFFIC
ZONE
WORK
BEGIN
PRESENT
ARE
WORKERS
WHEN
36x24
G20-5aP
48x42
R20-3T
STATE LAW
SIGNS
WARNING
OBEY
48x24
G20-2
ROAD WORK
END
WORK ZONE
END
48x24
G20-2bT
48x24
G20-2
ROAD WORK
ENDWORK ZONE
END
48x24
G20-2bT
48x24
G20-2
ROAD WORK
END
WORK ZONE
END
48x24
G20-2bT
CLOSED
SIDEWALK
24x12
R9-9
48x42
R20-3T
STATE LAW
SIGNS
WARNING
OBEY
48x48
CW20-1
AHEAD
WORK
ROAD
48x48
CW20-1
AHEAD
WORK
ROAD
48x48
CW20-1
AHEAD
WORK
ROAD
NEXT X MILES
ROAD WORK
BEGIN
STATE
CITY
ADDRESS
NAME
CONTRACTOR
48x30
G20-6T
36X24
G20-5T
NEXT X MILES
ROAD WORK
BEGIN
STATE
CITY
ADDRESS
NAME
CONTRACTOR
48x30
G20-6T
36X24
G20-5T
36x36
R20-5aTP
36x36
R20-5T
DOUBLE
FINES
TRAFFIC
ZONE
WORK
BEGIN
PRESENT
ARE
WORKERS
WHEN
36x24
G20-5aP
48x48
CW1-4L
CITY OF DENTON - McKINNEY STREET PHASE TWO1:80
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TCP12.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TCP12.dgn1:804:38:21 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
20 40 60 80
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
NOTES:
PERMANENT TRANSITION PAVEMENT.
THE SOUTH SIDE/EAST-BOUND LANES AND
WEST-BOUND LANES ON THE NORTH SIDE AND BUILD
PHASE 2: CONTRACTOR TO SHIFT TRAFFIC TO NEW
TRANSITION PAVEMENT.
NORTH SIDE/WEST-BOUND LANES AND TEMPORARY
SOUTH SIDE OF EXISTING PAVEMENT AND BUILD
PHASE 1: CONTRACTOR TO SHIFT TRAFFIC TO
SUGGESTED SEQUENCE OF CONSTRUCTION:
BARRIER FOR CONSTRUCTION
PHASE 2 TRAFFIC
CONSTRUCTION
PHASE 2 TEMP. PAVEMENT
PAVEMENT CONSTRUCTION
PHASE 2
LEGEND:
TRAFFIC FLOW
PHASE 2 SIGN
2019
SEP
OF CONSTRUCTION - PHASE TWO
TRAFFIC CONTROL SEQUENCE
INSPECTOR.
AND AS APPROVED BY CITY OF DENTON
BARRIERS BETWEEN PHASES, PER TEXAS MUTCD,
3. CONTRACTOR TO PROVIDE ADEQUATE TRAFFIC
ALL TIMES.
2. CONTRACTOR TO MAINTAIN LOCAL ACCESS AT
CONSTRUCTION ZONE SIGNING.
1. CONTRACTOR TO FOLLOW TEXAS MUTCD FOR
CHANNELIZING DEVICE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN ISV
PA
RKING AR
EA
PARKING AREA
E
PARKIN
G AREAS
S
S
S ONLYONLYONLYONLYONLYONLYONLY
ONLY
101 S LOO
P 288D
NB I
NVESTM
EN
TS LTDLOOP 288
7-ELEVEN INC
LOOP 2887-ELEV
EN I
NC3612 E McKINNEY STREET
McKINNEY BUILDING, LP
3612 E McKINNEY STREET
McKINNEY BUILDING, LP
LOT 41LOT 24A
LOT 1 LOT 24A
LOT 1
LOT 1
LOT 13621 E McKINNEY STREET
DENNIS J KOOP
101 S LOOP 288
INVESTMENT COMPANY
SEJ ASSET MANAGEMENT & 10
1 S LOOP 288I
NVESTM
EN
T COM
PAN
YSEJ ASSET M
ANA
GEMENT
&
88+00
89+00
91+0090+0086+0085+00
92+0093+0087+00 10071+0010072+0010073+0010074+0010075+0010076+00 PC 86+94.15 PT 90+20.18McKINNEY STREET N LOOP 288S LOOP 28821
CL McKINNEY STREET
3612 E McKINNEY STREET
McKINNEY BUILDING, LP
LOT 2R
101 N LOOP 288
DENNIS J KOOP
LOT 1
101 S LOO
P 288D
NB I
NVESTM
EN
TS LTDLOT 41320'320'(TYP.)320'640'(TYP.)320'320'(TYP.)320'640'(TYP.)17
TRAFFIC CONTROL
FOR PH. 2 McKINNEY ST
THROUGHSEE SHEETS 20
TRAFFIC CONTROL
LOOP 288 PHASE TWO
NEXT X MILES
ROAD WORK
BEGIN
STATE
CITY
ADDRESS
NAME
CONTRACTOR
48x30
G20-6T
36X24
G20-5T
48x48
CW20-1
AHEAD
WORK
ROAD
36x36
R20-5aTP
36x36
R20-5T
DOUBLE
FINES
TRAFFIC
ZONE
WORK
BEGIN
PRESENT
ARE
WORKERS
WHEN
36x24
G20-5aP
48x42
R20-3T
STATE LAW
SIGNS
WARNING
OBEY
WORK ZONE
END
48x24
G20-2bT
48x24
G20-2
ROAD WORK
END
48x24
G20-2
ROAD WORK
END
WORK ZONE
END
48x24
G20-2bT
48x42
R20-3T
STATE LAW
SIGNS
WARNING
OBEY
36x36
R20-5aTP
36x36
R20-5T
DOUBLE
FINES
TRAFFIC
ZONE
WORK
BEGIN
PRESENT
ARE
WORKERS
WHEN
36x24
G20-5aP
48x48
CW20-1
AHEAD
WORK
ROAD
NEXT X MILES
ROAD WORK
BEGIN
STATE
CITY
ADDRESS
NAME
CONTRACTOR
48x30
G20-6T
36X24
G20-5T
CITY OF DENTON - McKINNEY STREET PHASE TWO1:80
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TCP13.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TCP13.dgn1:804:38:24 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
20 40 60 80
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
NOTES:
PERMANENT TRANSITION PAVEMENT.
THE SOUTH SIDE/EAST-BOUND LANES AND
WEST-BOUND LANES ON THE NORTH SIDE AND BUILD
PHASE 2: CONTRACTOR TO SHIFT TRAFFIC TO NEW
TRANSITION PAVEMENT.
NORTH SIDE/WEST-BOUND LANES AND TEMPORARY
SOUTH SIDE OF EXISTING PAVEMENT AND BUILD
PHASE 1: CONTRACTOR TO SHIFT TRAFFIC TO
SUGGESTED SEQUENCE OF CONSTRUCTION:
BARRIER FOR CONSTRUCTION
PHASE 2 TRAFFIC
CONSTRUCTION
PHASE 2 TEMP. PAVEMENT
PAVEMENT CONSTRUCTION
PHASE 2
LEGEND:
TRAFFIC FLOW
PHASE 2 SIGN
2019
SEP
OF CONSTRUCTION - PHASE TWO
TRAFFIC CONTROL SEQUENCE
INSPECTOR.
AND AS APPROVED BY CITY OF DENTON
BARRIERS BETWEEN PHASES, PER TEXAS MUTCD,
3. CONTRACTOR TO PROVIDE ADEQUATE TRAFFIC
ALL TIMES.
2. CONTRACTOR TO MAINTAIN LOCAL ACCESS AT
CONSTRUCTION ZONE SIGNING.
1. CONTRACTOR TO FOLLOW TEXAS MUTCD FOR
CHANNELIZING DEVICE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
V
PARKING AREA PARKING AREA
PARKING AREA
CONCRETE
CONCRETE
CONCRETE
E
E
PARKING AREA
PARKING AREA
PARKING AREA
PARKING AREA
S
S
S
D
D
S
D
S
LOT 1R
3919/3921 E McKINNEY STREET
NSA PROPERTY HOLDINGS, LLC
LOT 3
3916 E McKINNEY STREET
EDWARD D & SHARYL K DIELEMAN
LOT 4
STREET
3918-3920 E McKINNEY
ORINGDERFF
LESLIE A & MICHAEL L
LOT 3
3923 E McKINNEY STREET
3919 McKINNEY, LLC
LOT 152
STREET
McKINNEY
4001 E
DENTON
CITY OF
LOT 153
E McKINNEY STREET
CITY OF DENTON
LOT 154
4301 E McKINNEY STREET
CITY OF DENTON
LOT 5R1
3922 E McKINNEY STREET
GOEL VENTURES ONE, LLC
LOT 151 (PT)
E McKINNEY STREET (200' STRIP)
BCI REAL ESTATE VENTURES, LP
D D
112+00111+00 115+00114+00110+00109+00 116+00 117+00113+00224+00223+0
0222+00221+00 PC 111+52.17 PC 116+81.83 PT 112+56.8922
McKINNEY STREETN MAYHI
LL ROADS MAYHI
LL ROADCLOSED
SIDEWALK
30x18
R9-9
320'
(TYP.
)320'320'
(TYP.
)320'640'
(TYP.
)640'
(TYP.
)
17
TRAFFIC CONTROL
FOR PH. 2 McKINNEY ST
THROUGHSEE SHEETS 20
CONSTRUCTED BY OTHERS
STATION 119+50 TO BE
STREET STATION 106+00 TO
INTERSECTION AND McKINNEY
MAYHILL ROAD/McKINNEY STREET
REFERENCE ONLY
TRAFFIC CONTROL
MAYHILL PHASE TWO
NEXT X MILES
ROAD WORK
BEGIN
STATE
CITY
ADDRESS
NAME
CONTRACTOR
48x30
G20-6T
36X24
G20-5T
48x48
CW20-1
AHEAD
WORK
ROAD
36x36
R20-5aTP
36x36
R20-5T
DOUBLE
FINES
TRAFFIC
ZONE
WORK
BEGIN
PRESENT
ARE
WORKERS
WHEN
36x24
G20-5aP
48x42
R20-3T
STATE LAW
SIGNS
WARNING
OBEY
WORK ZONE
END
48x24
G20-2bT
CLOSED
SIDEWALK
24x12
R9-9
CLOSED
SIDEWALK
24x12
R9-9
48x24
G20-2
ROAD WORK
END
CLOSED
SIDEWALK
24x12
R9-9
48x24
G20-2
ROAD WORK
END
WORK ZONE
END
48x24
G20-2bT
36x36
R20-5aTP
36x36
R20-5T
DOUBLE
FINES
TRAFFIC
ZONE
WORK
BEGIN
PRESENT
ARE
WORKERS
WHEN
36x24
G20-5aP
48x42
R20-3T
STATE LAW
SIGNS
WARNING
OBEY
48x48
CW20-1
AHEAD
WORK
ROAD
NEXT X MILES
ROAD WORK
BEGIN
STATE
CITY
ADDRESS
NAME
CONTRACTOR
48x30
G20-6T
36X24
G20-5T 320'320'
CITY OF DENTON - McKINNEY STREET PHASE TWO1:80
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TCP14.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TCP14.dgn1:804:38:27 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
20 40 60 80
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
NOTES:
PERMANENT TRANSITION PAVEMENT.
THE SOUTH SIDE/EAST-BOUND LANES AND
WEST-BOUND LANES ON THE NORTH SIDE AND BUILD
PHASE 2: CONTRACTOR TO SHIFT TRAFFIC TO NEW
TRANSITION PAVEMENT.
NORTH SIDE/WEST-BOUND LANES AND TEMPORARY
SOUTH SIDE OF EXISTING PAVEMENT AND BUILD
PHASE 1: CONTRACTOR TO SHIFT TRAFFIC TO
SUGGESTED SEQUENCE OF CONSTRUCTION:
BARRIER FOR CONSTRUCTION
PHASE 2 TRAFFIC
CONSTRUCTION
PHASE 2 TEMP. PAVEMENT
PAVEMENT CONSTRUCTION
PHASE 2
LEGEND:
TRAFFIC FLOW
PHASE 2 SIGN
2019
SEP
OF CONSTRUCTION - PHASE TWO
TRAFFIC CONTROL SEQUENCE
INSPECTOR.
AND AS APPROVED BY CITY OF DENTON
BARRIERS BETWEEN PHASES, PER TEXAS MUTCD,
3. CONTRACTOR TO PROVIDE ADEQUATE TRAFFIC
ALL TIMES.
2. CONTRACTOR TO MAINTAIN LOCAL ACCESS AT
CONSTRUCTION ZONE SIGNING.
1. CONTRACTOR TO FOLLOW TEXAS MUTCD FOR
CHANNELIZING DEVICE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
D
D
CONCRETE
PBX
PBX
E
36" TREE
36" PECAN
2" TREE
36" PECAN
2" TREE
48" PECAN
DBL. 4"/15" HACKBERRY
6" HACKBERRY
21" CEDAR
8" HACKBERRY
DBL. 15"/24" PECAN
24" PECAN
S
130+00
129+00
131+00 133+00132+00
128+00
125+00
127+00
126+00
PT 125+28.65 PC 129+61.6120' PUBLIC UTILITY
EASEMENT
DOC # 99-R0077309
LOT 167
LOT 151 (PT)
LOT 168
LOT 169
LOT 151 (PT)
LOT 1R4
LOT 150
4683 E McKINNEY STREETSAYR RESOURCES INC
BCI REAL ESTATE VENTURES,LP
5001 E McKINNEY STREETBARBARA McDONALD COBB
5043 E McKINNEY STREET
CHELA DARLINE McDONALD
BCI REAL ESTATE VENTURES,LP
5101 E McKINNEY STREET
DENTON ISD
5090 E McKINNEY STREET
EDIBERTO A RODRIGUEZ
23
McKINNEY STREET RYAN WAYCARPENTER ROAD20'LOT 1R4
5101 E McKINNEY STREET
DENTON ISD
LOT 168
McKINNEY STREET5001 E
COBB
McDONALDBARBARA
LOT 167
4683 E McKINNEY STREETSAYR RESOURCES INC
CONSTRUCTION
BARRIER FOR
WEST BOUND LANES
CONSTRUCT
CL McKINNEY STREET
PAINTED STRIPE
4" DOUBLE YELLOW
CURB
BARRELS TO PROTECT
CURB TO ALLOW FOR
OF TRAVEL LANE AND
3' GAP BETWEEN EDGE
(TYP.
)320'640'(TYP.)3
2
0'
3
2
0'
(TYP.
)
3
2
0'6
4
0'
(TYP.
)
17
TRAFFIC CONTROL
FOR PH. 2 McKINNEY ST
THROUGHSEE SHEETS 20
TWO TRAFFIC CONTROL
AND RYAN WAY PHASE
CARPENTER ROAD
CLOSED
SIDEWALK
24x12
R9-9
NEXT X MILES
ROAD WORK
BEGIN
STATE
CITY
ADDRESS
NAME
CONTRACTOR
48x30
G20-6T
36X24
G20-5T
48x48
CW20-1
AHEAD
WORK
ROAD
48x42
R20-3T
STATE LAW
SIGNS
WARNING
OBEY
WORK ZONE
END
48x24
G20-2bT
48x24
G20-2
ROAD WORK
END
36x36
R20-5aTP
36x36
R20-5T
DOUBLE
FINES
TRAFFIC
ZONE
WORK
BEGIN
PRESENT
ARE
WORKERS
WHEN
36x24
G20-5aP
48x24
G20-2
ROAD WORK
END
WORK ZONE
END
48x24
G20-2bT
36x36
R20-5aTP
36x36
R20-5T
DOUBLE
FINES
TRAFFIC
ZONE
WORK
BEGIN
PRESENT
ARE
WORKERS
WHEN
36x24
G20-5aP
48x42
R20-3T
STATE LAW
SIGNS
WARNING
OBEY
48x48
CW20-1
AHEAD
WORK
ROAD
NEXT X MILES
ROAD WORK
BEGIN
STATE
CITY
ADDRESS
NAME
CONTRACTOR
48x30
G20-6T
36X24
G20-5T 320'
SHEET 1 OF 12
7-13
BC(1)-14
8-14
bc-14.dgn
3.0" Radius, 1.25" Border, 0.75" Indent, Black on Yellow;
3.0" Radius, 1.25" Border, 0.75" Indent, Black on Orange;
.75"1.5"2"2"BACKGROUND
ORANGE
AND SYMBOL
BORDER
LEGEND,
BLACK
R=1.1".94.94.94.94.41.42.31"1"
.67".67"
1".31"
9"
R=.44"
R=.79"
R=.13".31".31"14".31"1.14"1.14"R=.75"2.57"2.88"1.17"5.55"17.5"6.38"
1.68"1.68"1.68"
8.38"
4.9"19.7"6"24.5"4.9"3.25"6"D12"48"4"1.25"3.5"20"36"3.5"5"C20"20"20"
3.5"12"2.8"6.3"2.8"11.7"2.8"14.6"3.5"
60"
1.25"
SIGN DETAIL (G20-10T)5"LEGEND
BORDER AND
BLACK
BACKGROUND
YELLOW
COLORS:.41[STAY ALERT] Font: D
[TALK OR TEXT LATER] Font: C specified length;
WHITE
BLACK
WHITER=.26"
R=1.5"
DN:CK:DW:CK:FILE:
---
-
JOB
COUNTY
SECT
DIST
REVISIONS
TxDOT TxDOT TxDOT TxDOT
-
HIGHWAY
-
SHEET NO.
C TxDOTof this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:CONTNovember 2002 FILE:DATE:$FILE$$DATE$$TIME$ 95
AND REQUIREMENTS
GENERAL NOTES
BARRICADE AND CONSTRUCTION
4-03
9-07
5-10
Standard
Division
Operations
Traffic
http://www.txdot.gov
THE DOCUMENTS BELOW CAN BE FOUND ON-LINE AT
COMPLIANT WORK ZONE TRAFFIC CONTROL DEVICES LIST (CWZTCD)
TEXAS MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (TMUTCD)
STANDARD HIGHWAY SIGN DESIGNS FOR TEXAS (SHSD)
TRAFFIC ENGINEERING STANDARD SHEETS
MATERIAL PRODUCER LIST (MPL)
ROADWAY DESIGN MANUAL - SEE "MANUALS (ONLINE MANUALS)"
DEPARTMENTAL MATERIAL SPECIFICATIONS (DMS)
Phone (512) 416-3118
Traffic Operations Division - TE
Texas Department of Transportation
below or by contacting:
and their sources and may be found on-line at the web address given
Traffic Control Devices List" (CWZTCD) describes pre-qualified products
Only pre-qualified products shall be used. The "Compliant Work Zone
BARRICADE AND CONSTRUCTION (BC) STANDARD SHEETS GENERAL NOTES:
or as approved by the Engineer.
right-of-way line as possible, or located behind a barrier or guardrail,
must be parked away from travel lanes. They should be as close to the
13. Inactive equipment and work vehicles, including workers' private vehicles
devices.
12. The Engineer has the final decision on the location of all traffic control
exists.
be in place only while work is actually in progress or a definite need
11. Except for devices required by Note 10, traffic control devices should
shall be erected at or near the CSJ limits.
strips. The BEGIN ROAD WORK NEXT X MILES, CONTRACTOR and END ROAD WORK signs
solely of mobile operation work, such as striping or milling edgeline rumble
the TRAFFIC FINES DOUBLE sign will not be required on projects consisting
sign with plaque shall be erected in advance of the CSJ limits. However,
TEXT LATER (see Sign Detail G20-10T) and the WORK ZONE TRAFFIC FINES DOUBLE
10. As shown on BC(2), the OBEY WARNING SIGNS STATE LAW sign, STAY ALERT TALK OR
appropriate traffic control devices to be used.
BC sheets are examples. As necessary, the Engineer will determine the most
9. The temporary traffic control devices shown in the illustrations of the
provide a detail to the Contractor before the sign is manufactured.
not shown in this manual shall be shown in the plans or the Engineer shall
"Standard Highway Sign Designs for Texas," latest edition. Sign details
8. All signs shall be constructed in accordance with the details found in the
justify the signing.
divided highways where median width will permit and traffic volumes
7. The Engineer may require duplicate warning signs on the median side of
revised to show appropriate work zone distance.
directed by the Engineer. The BEGIN ROAD WORK NEXT X MILES sign shall be
necessary warning signs as shown on these sheets, the TCP sheets or as
adjacent project is completed first, the Contractor shall erect the
redundant and the work areas appear continuous to the motorists. If the
FINES DOUBLE, and other advance warning signs if the signing would be
6. When projects abut, the Engineer(s) may omit the END ROAD WORK, TRAFFIC
Design Manual" or engineering judgment.
"A Policy on Geometric Design of Highways and Streets," the TxDOT "Roadway
Association of State Highway and Transportation Officials (AASHTO),
applicable design criteria contained in manuals such as the American
5. Geometric design of lane shifts and detours should, when possible, meet the
the approximate location of any device without the approval of the Engineer.
control devices as shown in the plans. The Contractor may not move or change
4. The Contractor is responsible for installing and maintaining the traffic
sign and seal Contractor proposed changes.
by a licensed professional engineer for approval. The Engineer may develop,
3. The Contractor may propose changes to the TCP that are signed and sealed
responsibility of the Engineer.
2. The development and design of the Traffic Control Plan (TCP)is the
shown in the "Texas Manual on Uniform Traffic Control Devices" (TMUTCD).
The information contained in these sheets meet or exceed the requirements
devices, construction pavement markings, and typical work zone signs.
to show typical examples for placement of temporary traffic control
1. The Barricade and Construction Standard Sheets (BC sheets) are intended
WORKER SAFETY APPAREL NOTES:
considered for high traffic volume work areas or night time work.
performance for Class 2 or 3 risk exposure. Class 3 garments should be
Apparel," or equivalent revisions, and labeled as ANSI 107-2004 standard
the requirements of ISEA "American National Standard for High-Visibility
within the right-of-way shall wear high-visibility safety apparel meeting
1. Workers on foot who are exposed to traffic or to construction equipment
24
SHEET 2 OF 12
7-13
(G20-1bTR)" signs shall be replaced by the detour signing called for in the plans.
The "ROAD WORK NEXT X MILES" left arrow(G20-1bTL) and "ROAD WORK NEXT X MILES" right arrow
NAME"(G20-6T) sign behind the Type 3 Barricades for the road closure (see BC(10) also).
2. If construction closes the road at a T-intersection the Contractor shall place the "CONTRACTOR
being performed at or near an intersection.
such as a flagger and accompanying signs, or other signs, that should be used when work is
1. The Engineer will determine the types and location of any additional traffic control devices,
PROJECT LIMIT
BARRICADE AND CONSTRUCTION
the plans or as determined by the Engineer/Inspector, shall be in place.
6. When work occurs in the intersection area, appropriate traffic control devices, as shown elsewhere in
5. Additional traffic control devices may be shown elsewhere in the plans for higher volume crossroads.
will determine whether a roadway is considered high volume.
motorists of the length of construction in either direction from the intersection. The Engineer
4. The "ROAD WORK NEXT X MILES"(G20-1aT)sign shall be required at high volume crossroads to advise
Zone Standard Sheets.
location and spacing of any sign not shown on the BC sheets, Traffic Control Plan sheets or the Work
be considered part of the minimum requirements. The Engineer/Inspector will determine the proper
AHEAD, LOOSE GRAVEL, or other appropriate signs. When additional signs are required, these signs will
3. Based on existing field conditions, the Engineer/Inspector may require additional signs such as FLAGGER
in the plans.
crossroads. The Engineer will determine whether a road is low volume. This information shall be shown
Texas" manual for sign details. The Engineer may omit the advance warning signs on low volume
"Typical Construction Warning Sign Size and Spacing"). See the "Standard Highway Sign Designs for
with the reduced size 36" x 18" "END ROAD WORK"(G20-2) sign on low volume crossroads (see Note 4 under
2. The Engineer may use the reduced size 36" x 36" ROAD WORK AHEAD (CW20-1D) sign mounted back to back
(G20-2) "END ROAD WORK" sign, unless noted otherwise in plans.
1. The typical minimum signing on a crossroad approach should be a "ROAD WORK AHEAD" (CW20-1D)sign and a
location
with sign
coordinate
line should
NO-PASSING
Beginning of
BC(2)-14
8-14
*G20-10T
appropriate)
(as
R4-1
sizes.
Sign Designs for Texas" manual for complete list of available sign design
6. See sign size listing in "TMUTCD", Sign Appendix or the "Standard Highway
5. Only diamond shaped warning sign sizes are indicated.
Location of Crossroad Signs".
crossroads at the discretion of the Engineer. See Note 2 under "Typical
4. 36" x 36" "ROAD WORK AHEAD" (CW20-1D)signs may be used on low volume
or more advance warning.
3. Distance between signs should be increased as required to have 1/2 mile
advance warning.
2. Distance between signs should be increased as required to have 1500 feet
1. Special or larger size signs may be used as necessary.
work area and/or distance between each additional sign.
Minimum distance from work area to first Advance Warning sign nearest the
(TMUTCD) typical application diagrams or TCP Standard Sheets.
see Part 6 of the "Texas Manual on Uniform Traffic Control Devices"
For typical sign spacings on divided highways, expressways and freeways,
G20-10T
(See note 2 below)
May be mounted on back of "ROAD WORK AHEAD"(CW20-1D) sign with approval of Engineer.
DN:CK:DW:CK:FILE:
---
-
JOB
COUNTY
SECT
DIST
REVISIONS
TxDOT TxDOT TxDOT
-
HIGHWAY
-
SHEET NO.
C TxDOT
of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:CONT
bc-14.dgn
November 2002 FILE:DATE:$FILE$$DATE$$TIME$96
R11-2
ROAD
CLOSED
XX
ROAD
WORK
AHEAD
END
ROAD WORK
END
ROAD WORK
CW20-1D
CW1-6
ROAD
WORK
AHEAD
CW20-1D
NAME
ADDRESS
CITY
STATE
CONTRACTOR
ROAD WORK
NEXT X MILES
BEGIN
ROAD
WORK
AHEAD
ROAD
WORK
AHEAD PROJECT1 Block - City
1 Block - City
ROAD WORK
NEXT X MILESROAD WORK
END
ROAD WORK
NEXT X MILES
PROJECTCROSSROAD
*
X
X
X
X
ROAD
WORK
AHEAD
END
ROAD WORK
END
ROAD WORK
CW20-1D
NAME
ADDRESS
CITY
STATE
CONTRACTOR
WORK
ZONE
TRAFFIC
FINES
DOUBLE
WHEN
WORKERS
ARE PRESENT
*
*
ROAD WORK
BEGIN
T-INTERSECTION
ROAD
WORK
AHEAD
CW20-1D
CW20-1D
CW20-1D
3X
3X
XX
ROAD WORK
NEXT X MILES
ROAD WORK
NEXT X MILES
NEXT X MILES
INTERSECTED
ROADWAY 1000'-1500' - Hwy
1000'-1500' - Hwy
CSJ Limit
CSJ Limit
XXXXX
XXXXX
*
1,5,6
X
X
TYPICAL LOCATION OF CROSSROAD SIGNS
X
X
WORK
ZONE
TRAFFIC
FINES
DOUBLE
WHEN
WORKERS
ARE PRESENT
WORK
ZONE
TRAFFIC
FINES
DOUBLE
WHEN
WORKERS
ARE PRESENT
R20-5T
G20-5T
G20-5T
CW1-4R
WORK AREAS IN MULTIPLE LOCATIONS WITHIN CSJ LIMITS
SAMPLE LAYOUT OF SIGNING FOR WORK BEGINNING AT THE CSJ LIMITS
**
**
**
**
**
**
**
**
**
SAMPLE LAYOUT OF SIGNING FOR WORK BEGINNING DOWNSTREAM OF THE CSJ LIMITS
CW1-4L
**
CW20-1E
WORK
ROAD G20-5T
/ MILE1
2
NEXT X MILES
*
*
TYPICAL CONSTRUCTION WARNING SIGN SIZE AND SPACING
30
MPH
35
40
45
50
55
60
320
400
500
600
Posted
Speed
Sign
Spacing
(Apprx.)
2
65 700
70 800
3**
2
2
2
"X"
Feet
120
160
240
75 900 2
80 1000 2
SPACINGSIZE
4
9-07
Devices
Channelizing
Devices
Channelizing
min.
80'
AREA
WORK
Limit
CSJ
1 and 4)
see Note
(Optional
1 and 4)
see Note
(Optional
G20-2
G20-1aT
G20-1aT
NEXT X MILES
G20-2
CW13-1P
SPACE
WORK
CW13-1PMPH
MPH
G20-2
SPACE
WORK
Channelizing Devices
LEGEND
Sign
Type 3 Barricade
spacing requirements.
TMUTCD for sign
Spacing chart or the
Warning Sign Size and
See Typical Construction
G20-1bTR G20-1bTL
R20-5T
R20-5aTP G20-6T
G20-2
R20-5aTP
R20-5T
G20-5aP
G20-5aP
G20-2
G20-6T
channelizing devices
Type 3 Barricade or
devices
channelizing
Barricade or
Type 3
G20-6T
GENERAL NOTES
or Series
Number
Sign
Freeway
Expressway/
Road
Conventional
CW20
CW21
CW22 48" x 48" 48" x 48"
CW23
CW25
CW1, CW2,
CW7, CW8, 36" x 36" 48" x 48"
CW9, CW11,
CW14
CW3, CW4,
CW5, CW6, 48" x 48" 48" x 48"
CW8-3,
CW10, CW12
CSJ LIMITS AT T-INTERSECTION
R20-3T
**
TxDOT
G20-5aP
R20-5aTP
Standard
Division
Operations
Traffic
X
channelizing devices.
within the project limits. See the applicable TCP sheets for exact location and spacing of signs and
"ROAD WORK AHEAD"(CW20-1D)signs are placed in advance of these work areas to remind drivers they are still
When extended distances occur between minimal work spaces, the Engineer/Inspector should ensure additional
WARNING
SIGNS
STATE LAW
OBEY
**R20-3T*
WARNING
SIGNS
STATE LAW
OBEY
WORK
ZONE
TRAFFIC
FINES
DOUBLE
WHEN
WORKERS
ARE PRESENT
BEGIN**G20-9TP
**R20-5T
**R20-5aTP
SPEED
LIMIT
XX
X
*
SPEED
LIMIT
XX*
R2-1
R2-1
R2-1
SPEED
LIMIT
XX
*
X
XX
CW1-4L
MPHCW13-1P
NAME
ADDRESS
CITY
STATE
CONTRACTOR
ROAD WORK
NEXT X MILES
BEGIN
*
**
*
NOTES
* the end of the work zone.
Contractor will install a regulatory speed limit sign at
Control Plan.
and other signs or devices as called for on the Traffic
Area for placement of "ROAD WORK AHEAD" (CW20-1D)sign
consisting solely of mobile operations work.
FINES DOUBLE signs will not be required on projects
Required CSJ Limit signing. See Note 10 on BC(1). TRAFFIC
if workers are present.
lying outside the CSJ Limits where traffic fines may double
motorist of entering or leaving a part of the work zone
signs are required outside the CSJ Limits. They inform the
shall be used as shown on the sample layout when advance
The "BEGIN WORK ZONE"(G20-9TP) and "END WORK ZONE" (G20-2bT)
No decimals shall be used.
to the nearest whole mile with the approval of the Engineer.
This distance shall replace the "X" and shall be rounded
WORK NEXT X MILES"(G20-5T)sign for each specific project.
to be placed on the G20-1 series signs and "BEGIN ROAD
The Contractor shall determine the appropriate distance
DO
NOT
PASS
SPEED
LIMIT
R2-1
XX
**
X X
X
**
*
G20-2bT
END
WORK ZONE
**
25
SHEET 3 OF 12
7-13
WORK ZONE SPEED LIMIT
BARRICADE AND CONSTRUCTION
BC(3)-14
8-14
DN:CK:DW:CK:FILE:
---
-
JOB
COUNTY
SECT
DIST
REVISIONS
TxDOT TxDOT TxDOT
-
HIGHWAY
-
SHEET NO.
C TxDOTof this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:CONT
bc-14.dgn
November 2002 FILE:DATE:$FILE$$DATE$$TIME$97
TxDOT
9-07
Standard
Division
Operations
Traffic
SPEED
LIMIT
60
SPEED
LIMIT
70
TYPICAL APPLICATION OF WORK ZONE SPEED LIMIT SIGNS
WORK
ZONE
SPEED
LIMIT
60
WORK
ZONE WORK
ZONE
SPEED
LIMIT
70
(750' - 1500')(750' - 1500')
R2-1
R2-1
R2-1
R2-1
Reduced speeds should only be posted in the vicinity
of work activity and not throughout the entire project.
LIMIT
SPEED
CW3-5
See General Note 4
60
and approved by the Texas Transportation Commission, or by City Ordinance when within Incorporated City Limits.
Work zone speed limits shall be regulatory, established in accordance with the "Procedures for Establishing Speed Zones,"
or covered during periods when they are not needed.
Regulatory work zone speed signs (R2-1) shall be removed
signing.
additional advance
See BC(2) for
one direction only.
Signing shown for
LIMITS
CSJ
Note 4
See General
LIMIT
SPEED
CW3-5
60
G20-5aP
G20-5aP
SPEED
LIMIT
60
GENERAL NOTES
GUIDANCE FOR USE:
mounting height.
3. Speed zone signs are illustrated for one direction of travel and are normally posted
for each direction of travel.
40 mph and greater 0.2 to 2 miles
35 mph and less 0.2 to 1 mile
5. Regulatory speed limit signs shall have black legend and border on a white reflective
B. Flagger stationed next to sign.
A. Law enforcement.
C. Portable changeable message sign (PCMS).
This type of work zone speed limit should be included on the design of
the traffic control plans when restricted geometrics with a lower design
speed are present in the work zone and modification of the geometrics to
a higher design speed is not feasible.
Work activity may also be defined as a change in the roadway that requires
a reduced speed for motorists to safely negotiate the work area, including:
a) rough road or damaged pavement surface
b) substantial alteration of roadway geometrics (diversions)
c) construction detours
d) grade
e) width
As long as any of these conditions exist, the work zone speed limit signs
SHORT TERM WORK ZONE SPEED LIMITS
the traffic control plans when workers or equipment are not behind concrete
f) other conditions readily apparent to the driver
projects where speed control is of major importance.
E. Speed monitor trailers or signs.
D. Low-power (drone) radar transmitter.
(See Removing or Covering on BC(4)).
Long/Intermediate Term Work Zone Speed Limit signs, when approved as described
above, should be posted and visible to the motorist when work activity is present.
motorists only when work activity is present. When work activity is not
present, signs shall be removed or covered.
Short Term Work Zone Speed Limit signs should be posted and visible to the
background (See "Reflective Sheeting" on BC(4)).
4. Frequency of work zone speed limit signs should be:
8. Techniques that may help reduce traffic speeds include but are not limited to:
2. Regulatory work zone speed limit signs shall be placed on supports at a 7 foot minimum
should remain in place.
1. Regulatory work zone speed limits should be used only for sections of construction
LONG/INTERMEDIATE TERM WORK ZONE SPEED LIMITS
zone reduction see TxDOT form #1204 in the TxDOT e-form system.
conditions and factors impacting allowable regulatory construction speed
10.For more specific guidance concerning the type of work, work zone
Work Zone Speed Limits should only be posted as approved for each project.
9. Speeds shown on details above are for illustration only.
This type of work zone speed limit may be included on the design of
barrier, when work activity is within 10 feet of the traveled way or actually
in the travelled way.
otherwise noted under "REMOVING OR COVERING" on BC(4).
7. Turning signs from view, laying signs over or down will not be allowed, unless as
directly, but shall be considered subsidiary to Item 502.
"WORK ZONE"(G20-5aP) plaque and the "SPEED LIMIT"(R2-1)signs shall not be paid for
6. Fabrication, erection and maintenance of the"ADVANCE SPEED LIMIT"(CW3-5)sign,
Note 4
See General
R2-1
WORK
ZONE
SPEED
LIMIT
60 R2-1
signing.
additional advance
See BC(2) for
one direction only.
Signing shown for
G20-5aPG20-5aP
SPEED
LIMIT
70 R2-1
LIMITS
CSJ
26
SHEET 4 OF 12
7-13
TEMPORARY SIGN NOTES
BARRICADE AND CONSTRUCTION
BC(4)-14
8-14
DN:CK:DW:CK:FILE:
---
-
JOB
COUNTY
SECT
DIST
REVISIONS
TxDOT TxDOT TxDOT TxDOT
-
HIGHWAY
-
SHEET NO.
C TxDOTof this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:CONT
bc-14.dgn
November 2002 FILE:DATE:$FILE$$DATE$$TIME$98
9-07
Standard
Division
Operations
TrafficCurbXXTravel lane edge 12' min.
FRONT ELEVATION
SIDE ELEVATIONTravel lane edge OR
TYPICAL MINIMUM CLEARANCES FOR LONG TERM AND INTERMEDIATE TERM SIGNS
*
*
CONTRACTOR REQUIREMENTS FOR MAINTAINING PERMANENT SIGNS
WITHIN THE PROJECT LIMITS
0'-6'
1. Permanent signs are used to give notice of traffic laws or regulations, call
attention to conditions that are potentially hazardous to traffic operations,
show route designations, destinations, directions, distances, services, points
of interest, and other geographical, recreational, or cultural information.
Drivers proceeding through a work zone need the same, if not better route
guidance as normally installed on a roadway without construction.
2. When permanent regulatory or warning signs conflict with work zone conditions,
3. When existing permanent signs are moved and relocated due to construction
purposes, they shall be visible to motorists at all times.
4. If existing signs are to be relocated on their original supports, they shall be
installed on crashworthy bases as shown on the SMD Standard sheets. The signs
shall meet the required mounting heights shown on the BC Sheets or the SMD
Standards. This work should be paid for under the appropriate pay item for
relocating existing signs.
5. If permanent signs are to be removed and relocated using temporary supports,
the Contractor shall use crashworthy supports as shown on the BC sheets or the
CWZTCD. The signs shall meet the required mounting heights shown on the
BC Sheets or the SMD Standards during construction. This work should be paid
for under the appropriate pay item for relocating existing signs.
6. Any sign or traffic control device that is struck or damaged by the Contractor
or his/her construction equipment shall be replaced as soon as possible by the
Contractor to ensure proper guidance for the motorists. This will be subsidiary
to Item 502.
remove or cover the permanent signs until the permanent sign message matches
the roadway condition.
**
**
ATTACHMENT FOR SIGN SUPPORTS
Wood
STOP/SLOW PADDLES
10"10"
24"
24"
24"
24"
8"C 8"B
†"
9"8Å "
R=2"3"
„"+
6.0' min.
Fiber Reinforced Plastic
Wood, metal or
the ground.
SIZE OF SIGNS
SIGN SUBSTRATES
SIGN LETTERS
Hand Signaling Devices in the TMUTCD.
shall only be as specifically described in Section 6E.03
4. Any lights incorporated into the STOP or SLOW paddle faces
length of 6' to the bottom of the sign.
3. STOP/SLOW paddles may be attached to a staff with a minimum
retroreflectorized.
2. When used at night, the STOP/SLOW paddle shall be
as detailed below.
by flaggers. The STOP/SLOW paddle size should be 24" x 24"
1. STOP/SLOW paddles are the primary method to control traffic
curb
from
minimum
2 '
min.
6'
9.0' max.
7.0' min.
9.0' max.
7.0' min.
9.0' max.
7.0' min.
shoulder
Paved
shoulder
Paved
above sign
protrude
shall not
Support
above sign
protrude
shall not
Support
substrate.
back of the sign
1/2 way up the
extend more than
Sign supports shall
Legend & Border - White
Background - Red
Legend & Border - Black
Background - Orange
Supplemental plaques (advisory or distance) should not cover the surface of the parent sign.
When plaques are placed on dual-leg supports, they should be attached to the upright nearest the travel lane.
Objects shall NOT be placed under skids as a means of leveling.
When placing skid supports on unlevel ground, the leg post lengths must be adjusted so the sign appears straight and plumb.
MPH
be allowed.
other means.
by splicing or
extended or repaired
supports shall not be
any means. Wood
joined or spliced by
signs shall not be
support. Multiple
directly to the sign
shall be attached
Each sign
Nails shall NOT
sign supports
substrates to other types of
procedures for attaching sign
manufacturer's recommended
or screws. Use TxDOT's or
will be by bolts and nuts
Attachment to wooden supports
FLAGS ON SIGNS
greater
6' or
of at least the same gauge material.
should be at least 5 times nominal post size, centered on the splice and
the sign substrate, not near the base of the support. Splice insert lengths
above and two below the spice point. Splice must be located entirely behind
height will only be allowed when the splice is made using four bolts, two
Splicing embedded perforated square metal tubing in order to extend post
GENERAL NOTES FOR WORK ZONE SIGNS
1. Contractor shall install and maintain signs in a straight and plumb condition and/or as directed by the Engineer.
2. Wooden sign posts shall be painted white.
3. Barricades shall NOT be used as sign supports.
4. All signs shall be installed in accordance with the plans or as directed by the Engineer. Signs shall be used to regulate, warn, and
guide the traveling public safely through the work zone.
5. The Contractor may furnish either the sign design shown in the plans or in the "Standard Highway Sign Designs for Texas" (SHSD). The
Engineer/Inspector may require the Contractor to furnish other work zone signs that are shown in the TMUTCD but may have been omitted
from the plans. Any variation in the plans shall be documented by written agreement between the Engineer and the Contractor's
Responsible Person. All changes must be documented in writing before being implemented. This can include documenting the changes in
the Inspector's TxDOT diary and having both the Inspector and Contractor initial and date the agreed upon changes.
6. The Contractor shall furnish sign supports listed in the "Compliant Work Zone Traffic Control Device List" (CWZTCD). The Contractor
shall install the sign support in accordance with the manufacturer's recommendations. If there is a question regarding installation
procedures, the Contractor shall furnish the Engineer a copy of the manufacturer's installation recommendations so the Engineer can
verify the correct procedures are being followed.
7. The Contractor is responsible for installing signs on approved supports and replacing signs with damaged or cracked substrates and/or
damaged or marred reflective sheeting as directed by the Engineer/Inspector.
8. Identification markings may be shown only on the back of the sign substrate. The maximum height of letters and/or company logos used
for identification shall be 1 inch.
DURATION OF WORK (as defined by the "Texas Manual on Uniform Traffic Control Devices" Part 6)
1. The types of sign supports, sign mounting height,the size of signs, and the type of sign substrates can vary based on the type of
work being performed. The Engineer is responsible for selecting the appropriate size sign for the type of work being performed. The
Contractor is responsible for ensuring the sign support, sign mounting height and substrate meets manufacturer's recommendations in
regard to crashworthiness and duration of work requirements.
a. Long-term stationary - work that occupies a location more than 3 days.
more than one hour.
c. Short-term stationary - daytime work that occupies a location for more than 1 hour in a single daylight period.
d. Short, duration - work that occupies a location up to 1 hour.
e. Mobile - work that moves continuously or intermittently (stopping for up to approximately 15 minutes.)
SIGN MOUNTING HEIGHT
1. The bottom of Long-term/Intermediate-term signs shall be at least 7 feet, but not more than 9 feet, above the paved surface, except
as shown for supplemental plaques mounted below other signs.
2. The bottom of Short-term/Short Duration signs shall be a minimum of 1 foot above the pavement surface but no more than 2 feet above
3. Long-term/Intermediate-term Signs may be used in lieu of Short-term/Short Duration signing.
appropriate Long-term/Intermediate sign height.
5. Regulatory signs shall be mounted at least 7 feet, but not more than 9 feet, above the paved surface regardless of work duration.
REFLECTIVE SHEETING
1. All signs shall be retroreflective and constructed of sheeting meeting the color and retro-reflectivity requirements of DMS-8300
for rigid signs or DMS-8310 for roll-up signs. The web address for DMS specifications is shown on BC(1).
1. All sign letters and numbers shall be clear, and open rounded type uppercase alphabet letters as approved by the Federal Highway
Administration (FHWA) and as published in the "Standard Highway Sign Design for Texas" manual. Signs, letters and numbers shall be of
first class workmanship in accordance with Department Standards and Specifications.
REMOVING OR COVERING
1. When sign messages may be confusing or do not apply, the signs shall be removed or completely covered.
2. Long-term stationary or intermediate stationary signs installed on square metal tubing may be turned away from traffic 90 degrees when
3. Signs installed on wooden skids shall not be turned at 90 degree angles to the roadway. These signs should be removed or completely
covered when not required.
4. When signs are covered, the material used shall be opaque, such as heavy mil black plastic, or other materials which will cover the
9. The Contractor shall replace damaged wood posts. New or damaged wood sign posts shall not be spliced.
1. The Contractor shall furnish the sign sizes shown on BC (2) unless otherwise shown in the plans or as directed by the Engineer.
intersections where the sign may be seen from approaching traffic.
the sign message is not applicable. This technique may not be used for signs installed in the median of divided highways or near any
1. The Contractor shall ensure the sign substrate is installed in accordance with the manufacturer's recommendations for the type of sign
support that is being used. The CWZTCD lists each substrate that can be used on the different types and models of sign supports.
2. "Mesh" type materials are NOT an approved sign substrate, regardless of the tightness of the weave.
3. All wooden individual sign panels fabricated from 2 or more pieces shall have one or more plywood cleat, 1/2" thick by 6" wide,
fastened to the back of the sign and extending fully across the sign. The cleat shall be attached to the back of the sign using wood
screws that do not penetrate the face of the sign panel. The screws shall be placed on both sides of the splice and spaced at 6"
centers. The Engineer may approve other methods of splicing the sign face.
b. Intermediate-term stationary - work that occupies a location more than one daylight period up to 3 days, or nighttime work lasting
2. White sheeting, meeting the requirements of DMS-8300 Type A, shall be used for signs with a white background.
FL3. Orange sheeting, meeting the requirements of DMS-8300 Type B or Type C , shall be used for rigid signs with orange backgrounds.FL
4. Short-term/Short Duration signs shall be used only during daylight and shall be removed at the end of the workday or raised to
5. Burlap shall NOT be used to cover signs.
SIGN SUPPORT WEIGHTS
6. Duct tape or other adhesive material shall NOT be affixed to a sign face.
1. Where sign supports require the use of weights to keep from turning over,
the use of sandbags with dry, cohesionless sand should be used.
2. The sandbags will be tied shut to keep the sand from spilling and to
maintain a constant weight.
3. Rock, concrete, iron, steel or other solid objects shall not be permitted
for use as sign support weights.
4. Sandbags should weigh a minimum of 35 lbs and a maximum of 50 lbs.
5. Sandbags shall be made of a durable material that tears upon vehicular
6. Rubber ballasts designed for channelizing devices should not be used for
ballast on portable sign supports. Sign supports designed and manufactured
with rubber bases may be used when shown on the CWZTCD list.
7. Sandbags shall only be placed along or laid over the base supports of the
traffic control device and shall not be suspended above ground level or
hung with rope, wire, chains or other fasteners. Sandbags shall be placed
along the length of the skids to weigh down the sign support.
8. Sandbags shall NOT be placed under the skid and shall not be used to level
sign supports placed on slopes.
impact. Rubber (such as tire inner tubes) shall NOT be used.
the sign face.
red-orange in color. Flags shall not be allowed to cover any portion of
shall be 16 inches square or larger and shall be orange or fluorescent
1. Flags may be used to draw attention to warning signs. When used the flag
entire sign face and maintain their opaque properties under automobile headlights at night, without damaging the sign sheeting.
7. Signs and anchor stubs shall be removed and holes backfilled upon completion of work.
27
7-1384"41"21"131 1/2 "4"
sign panel and supports
(2 per support) joining
3/8" x 3" gr. 5 bolt
TYPICAL SIGN SUPPORT
BARRICADE AND CONSTRUCTION
SHEET 5 OF 12
BC(5)-14
8-14
DN:CK:DW:CK:
---
-
JOB
COUNTY
SECT
DIST
TxDOT TxDOT TxDOT TxDOT
-
HIGHWAY
-
SHEET NO.
CONT
FILE:DATE:$FILE$$DATE$$TIME$ 99of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:30"
40"
27"
36"
24"
2x6
2x4 x 40"
72"
2x6
Front Side
Top
*
*
that can be used for each approved sign support.
See the CWZTCD for the type of sign substrate
NOT be allowed. Posts shall be painted white.
Wood sign posts MUST be one piece. Splicing will
See BC(4) for definition of "Work Duration."
post
wood
4x4
sign face
21 sq. ft. of
Maximum
block
4x4
post
wood
4x4
requirement
height
for sign
See BC(4)
This will be considered subsidiary to Item 502.
foundations shall be removed from the project site.
3. When project is completed, all sign supports and
CWZTCD List.
7 ft. circle, except for specific materials noted on the
2. No more than 2 sign posts shall be placed within a
connection.
lag screws must be used on every joint for final
supports, but 3/8" bolts with nuts or 3/8" x 3 1/2"
1. Nails may be used in the assembly of wooden sign
GENERAL NOTES
Front
*
post
wood
4x4
requirement
height
for sign
See BC(4)
sign face
12 sq. ft. of
Maximum 24"
60"
2x6
2x6
Top
block
4x4
skid
2x6
additional stability.
be increased for
Length of skids may
24"2x4 brace
4x4 block4x4 block
Side
screws
(min.) lag
or 3/8" x 3 1/2"
3/8" bolts w/nuts
LONG/INTERMEDIATE TERM STATIONARY - PORTABLE SKID MOUNTED SIGN SUPPORTS
SKID MOUNTED WOOD SIGN SUPPORTS
PERFORATED SQUARE METAL TUBING
GROUND MOUNTED SIGN SUPPORTS
Two post installations can be used for larger signs.
The maximum sign square footage shall adhere to the manufacturer's recommendation.
Refer to the CWZTCD and the manufacturer's installation procedure for each type sign support.
4" max.
Ground surface
WING CHANNEL
Post
Sign
Post
Base
for embedment.
See the CWZTCD
48"
5'
square tubing
or 1 3/4" x 1 3/4"
with 5/16" holes
1 3/4" galv. round
(DO NOT SPLICE)
12 ga post
1 3/4" x 1 3/4" x 11 foot
CWZTCD LIST. SEE BC(1) FOR WEBSITE LOCATION.
AND SHORT TERM SUPPORTS CAN BE FOUND ON THE
MORE DETAILS OF APPROVED LONG/INTERMEDIATE
Posts
of
Number
MOUNTED SIGN SUPPORTS
WOOD POST SYSTEM FOR GROUND
WEDGE ANCHORS
18"
4"
*
4"
6"
of Traffic
Direction
Dia.(typ)
1 1/2"17 1/2"20 1/2"5 BOLT (TYP.)
3/8" X 4-1/2 gr.
3"
telescopes into sleeve
(hole to hole) 12 ga. support
1 3/4 " x 1 3/4 " x 129"
tubing diagonal brace
to hole) 12 ga. square perforated
1 3/4 " x 1 3/4 " x 52" (hole
tubing cross brace
to hole) 12 ga. square perforated
1 3/4 " x 1 3/4 " x 32" (hole
20 1/2"above pavement
provide 7' height
telescope to
Upright must
5 bolt
3/8 " X 3" gr.
Ground surface
Post
Sign
(Direct Embedment)
OPTION 1
max.
4"
Ground surface
Post
Sign
weak soils.
55" min. in
strong soils,
34" min. in
(Anchor Stub)
OPTION 2
post)
than sign
(1/4" larger
Anchor Stub
desirable
9"
max.
4"
Ground surface
Post
Sign
post) x 18"
than sign
(1/2" larger
sleeve
reinforcing
Optional
18"
weak soils.
55" min. in
strong soils,
34" min. in
(Anchor Stub and Reinforcing Sleeve))
OPTION 3
post)
than sign
(1/4" larger
Anchor Stub
desirable
9"
bolted anchor
Lap-splice/base
minimum
48"
sign only
thinwall plastic
10mm extruded
9 sq. ft. or less-
1/2" plywood is allowed.
the CWZTCD, except 5/8" plywood.
substrate listed in section J.2.d of
16 sq. ft. or less of any rigid sign
OTHER DESIGNS
"Traffic Engineering Standard Sheets" on BC(1)).
if approved by the Engineer. (See web address for
face. They may be set in concrete or in sturdy soils
sign supports for signs up to 10 square feet of sign
on the SMD Standard Sheets may be used as temporary
Both steel and plastic Wedge Anchor Systems as shown
FILE:
REVISIONS
C TxDOT
bc-14.dgn
November 2002
9-07
36"
match sideslope
needed to
pin at angle
weld starts here
weldhere
starts
weld
back fill puddle.
weld, do not
directions. Minimum
going in opposite
opposite sides
Welds to start on
48"
2"
Side View
upright
12 ga.
2" x 2" x
2.5'
60"
3"
SKID MOUNTED PERFORATED SQUARE STEEL TUBING SIGN SUPPORTS
around tubing
Completely welded8 1/2" 7/16"
32'SINGLE LEG BASE
5'
weld
welded to skid
tubing sleeve
perforated
12 ga. square
(hole to hole)
2" x 2" x 8"
tubing upright
perforated
12 ga. square
(hole to hole)
1 3/4 " x 1 3/4 " x 129"
tubing skid
12 ga. perforated
(hole to hole)
2" x 2" x 59"
Standard
Division
Operations
Traffic
28
SHEET 6 OF 12
MESSAGE SIGN (PCMS)
PORTABLE CHANGEABLE
BARRICADE AND CONSTRUCTION
abbreviated, unless shown in the TMUTCD.
bars is appropriate.
PCMS has malfunctioned. A pattern such as a series of horizontal solid
not alarm motorists and will only be used to alert workers that the
17. If disabled, the PCMS should default to an illegible display that will
left or right justified.
16. Each line of text should be centered on the message board rather than
and must be legible from at least 400 feet.
daylight. Truck mounted units must have a character height of 10 inches
should be legible from at least 600 feet at night and 800 feet in
units. They should be visible from at least 1/2 (.5) mile and the text
15. PCMS character height should be at least 18 inches for trailer mounted
13. Do not display messages that scroll horizontally or vertically across
11. Do not use the word "Danger" in message.
7-13of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER: no more than one week prior to the work.
a minimum of 1000 ft. Each PCMS shall be limited to two phases,
BC(6)-14
8-14
DN:CK:DW:CK:
---
-
JOB
COUNTY
SECT
DIST
REVISIONS
-
HIGHWAY
-
SHEET NO.
CONT
bc-14.dgn
November 2002 FILE:DATE:$FILE$$DATE$$TIME$100
Standard
Division
Operations
Traffic
TxDOT TxDOTTxDOT TxDOT FILE:
C TxDOT
9-07
PCMS SIGNS WITHIN THE R.O.W. SHALL BE BEHIND GUARDRAIL OR
CONCRETE BARRIER OR SHALL HAVE A MINIMUM OF FOUR (4)
PLASTIC DRUMS PLACED PERPENDICULAR TO TRAFFIC ON THE
LANES SHIFT in Phase 1 must be used with STAY IN LANE in Phase 2.**
Roadway
designation # IH-number, US-number, SH-number, FM-number
1. When Full Matrix PCMS signs are used, the character height and legibility/visibility requirements shall be maintained as listed in Note 15 under "PORTABLE
CHANGEABLE MESSAGE SIGNS" above.
shall maintain the legibility/visibility requirement listed above.
for, or replace that sign.
4. A full matrix PCMS may be used to simulate a flashing arrow board provided it meets the visibility, flash rate and dimming requirements on BC(7), for the
same size arrow.
FULL MATRIX PCMS SIGNS
Access Road ACCS RD Major MAJ
Construction
WORDING ALTERNATIVES
1. The words RIGHT, LEFT and ALL can be interchanged as appropriate.
2. Roadway designations IH, US, SH, FM and LP can be interchanged as
appropriate.
3. EAST, WEST, NORTH and SOUTH (or abbreviations E, W, N and S) can
be interchanged as appropriate.
4. Highway names and numbers replaced as appropriate.
5. ROAD, HIGHWAY and FREEWAY can be interchanged as needed.
6. AHEAD may be used instead of distances if necessary.
7. FT and MI, MILE and MILES interchanged as appropriate.
8. AT, BEFORE and PAST interchanged as needed.
9. Distances or AHEAD can be eliminated from the message if a
location phase is used.
3. When symbol signs are represented graphically on the Full Matrix PCMS, they shall only supplement the use of the static sign represented, and shall not substitute
APPLICATION GUIDELINES
1. Only 1 or 2 phases are to be used on a PCMS.
2. The 1st phase (or both) should be selected from the
"Road/Lane/Ramp Closure List" and the "Other Condition List".
3. A 2nd phase can be selected from the "Action to Take/Effect
on Travel, Location, General Warning, or Advance Notice
Phase Lists".
4. A Location Phase is necessary only if a distance or location
is not included in the first phase selected.
5. If two PCMS are used in sequence, they must be separated by
and should be understandable by themselves.
6. For advance notice, when the current date is within seven days
of the actual work date, calendar days should be replaced with
days of the week. Advance notification should typically be for
CLOSED
BLVD
XXXXXXXX
**LANE
IN
STAY
CONST AHD
CROSSING XING RT LN
Vehicles (s)VEH, VEHS
UPR LEVEL
LWR LEVEL
HR, HRS
1. The Engineer/Inspector shall approve all messages used on portable
changeable message signs (PCMS).
2. Messages on PCMS should contain no more than 8 words (about four to
eight characters per word), not including simple words such as "TO,"
"FOR," "AT," etc.
3. Messages should consist of a single phase, or two phases that
alternate. Three-phase messages are not allowed. Each phase of the
message should convey a single thought, and must be understood by
itself.
4. Use the word "EXIT" to refer to an exit ramp on a freeway; i.e.,
"EXIT CLOSED." Do not use the term "RAMP."
5. Always use the route or interstate designation (IH, US, SH, FM)
along with the number when referring to a roadway.
6. When in use the bottom of a stationary PCMS message panel should be
a minimum 7 feet above the roadway, where possible.
7. The message term "WEEKEND" should be used only if the work is to
start on Saturday morning and end by Sunday evening at midnight.
Actual days and hours of work should be displayed on the PCMS if work
is to begin on Friday evening and/or continue into Monday morning.
8. The Engineer/Inspector may select one of two options which are avail-
able for displaying a two-phase message on a PCMS. Each phase may be
displayed for either four seconds each or for three seconds each.
9. Do not "flash" messages or words included in a message. The message
should be steady burn or continuous while displayed.
10. Do not present redundant information on a two-phase message; i.e.,
keeping two lines of the message the same and changing the third line.
12. Do not display the message "LANES SHIFT LEFT" or "LANES SHIFT RIGHT"
on a PCMS. Drivers do not understand the message.
the face of the sign.
14. The following table lists abbreviated words and two-word phrases that
are acceptable for use on a PCMS. Both words in a phrase must be
displayed together. Words or phrases not on this list should not be
PORTABLE CHANGEABLE MESSAGE SIGNS
SHOULD BE PLACED WITH ONE DRUM AT EACH OF THE FOUR CORNERS OF THE UNIT.
OF TRAFFIC. WHEN EXPOSED TO TWO WAY TRAFFIC, THE FOUR DRUMS
UPSTREAM SIDE OF THE PCMS, WHEN EXPOSED TO ONE DIRECTION
WHEN NOT IN USE, REMOVE THE PCMS FROM THE RIGHT-OF-WAY OR PLACE THE PCMS
BEHIND BARRIER OR GUARDRAIL WITH SIGN PANEL TURNED PARALLEL TO TRAFFIC
WORD OR PHRASEABBREVIATION ABBREVIATION WORD OR PHRASE
2. When symbol signs, such as the "Flagger Symbol"(CW20-7) are represented graphically on the Full Matrix PCMS sign and, with the approval of the Engineer, it
RECOMMENDED PHASES AND FORMATS FOR PCMS MESSAGES DURING ROADWORK ACTIVITIES
Phase 2: Possible Component Lists
CAUTION
USE
Notice List
** Advance
List
Warning
XX MPH
SPEED
ADVISORY
XX MPH
LIMIT
SPEED
XX MPH
SPEED
MAXIMUM
XX MPH
SPEED
MINIMUM
EXIT
LANE
RIGHT
SAFELY
DRIVE
CARE
WITH
DRIVE
X PM
XX AM-
TUE-FRI
MONDAY
BEGINS
MAY XX
BEGINS
XX AM
XX PM -
MAY X-X
X PM-X AM
XX
APR XX-
FRI-SUN
NEXT
XX PM
TO
XX AM
AUG XX
TUE
NEXT
XX AM
XX PM-
TONIGHT
Road/Lane/Ramp Closure List
(The Engineer may approve other messages not specifically covered here.)
*
DELAYS
EXPECT
Other Condition List
Phase 1: Condition Lists
See Application Guidelines Note 6.
List
Action to Take/Effect on Travel
List
Location
XXX FT
CLOSED
SHOULDER
XXX FT
CLOSED
RIGHT LN
X MILE
CLOSED
EXIT XXX
CLOSED
TO BE
RIGHT LN
CLOSED
ROAD
FRONTAGE
OPEN
LANES
RIGHT X
CLOSURES
LANE
DAYTIME
CLOSED
EXIT
I-XX SOUTH
TUE - FRI
CLOSED
X LANES
XXX FT
ROADWORK
XXXX FT
FLAGGER
XXXX FT
NARROWS
RIGHT LN
XXXX FT
TRAFFIC
MERGING
XXXX FT
GRAVEL
LOOSE
X MILE
DETOUR
SH XXXX
PAST
ROADWORK
XXXX FT
BUMP
XXXX FT
SIGNAL
TRAFFIC
XXXX FT
REPAIRS
ROAD
XXXX FT
NARROWS
LANE
XX MILE
TRAFFIC
TWO-WAY
XXXX FT
LANES
UNEVEN
XXXX FT
ROAD
ROUGH
FRI-SUN
NEXT
ROADWORK
X MILES
EXIT
US XXX
SHIFT
LANES
SOUTH
US XXX
STAY ON
RIGHT
MERGE
X EXITS
NEXT
DETOUR
US XXX N
USE
TRUCKS
TRUCKS
FOR
WATCH
XXX FT
SPEED
REDUCE
ROUTES
OTHER
USE
RIGHT
X LINES
FORM
RD EXIT
XXXXX
USE
NORTH
I-XX
USE EXIT
TO I-XX N
I-XX E
USE
TRUCKS
FOR
WATCH
DELAYS
EXPECT
STOP
TO
PREPARE
USE
SHOULDER
END
WORKERS
FOR
WATCH
FM XXXX
AT
CROSSING
RAILROAD
BEFORE
MILES
X
NEXT
EXIT
US XXX
PAST
XXXXXXX
TO
XXXXXXX
FM XXXX
TO
US XXX
XXX FT
TRAFFIC
CONST
EXIT XXX
USE
CLOSED
EXIT
X MILE
CLOSED
FREEWAY
CLOSED
LANES
RIGHT X
CLOSED
LANES
VARIOUS
AT SH XXX
CLOSED
ROAD
FM XXXX
CLSD AT
ROAD
CLOSED
LANE
CENTER
CLOSURES
LANE
NIGHT
CLOSED
DRIVEWAY
MALL
29
30 square inches
reflective surface area of at least
or square.Must have a yellow
Warning reflector may be round
area. Their use shall be as indicated on this sheet and/or other sheets of the plans by the designation "FL". The Type A Warning Lights shall
not be used with signs manufactured with Type B or C Sheeting meeting the requirements of Departmental Material Specification DMS-8300.
BC(7)-14
7-13
WARNING LIGHTS & ATTENUATOR
ARROW PANEL, REFLECTORS,
BARRICADE AND CONSTRUCTION
DN:CK:DW:CK:FILE:
JOB
COUNTY
SECT
DIST
REVISIONS
TxDOT TxDOT TxDOT TxDOT
HIGHWAY
SHEET NO.
C TxDOT
CONT
bc-14.dgn
November 2002
101
9-07 8-14
---
--
-
of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:FILE:DATE:$FILE$$DATE$$TIME$CONCRETE TRAFFIC BARRIER (CTB)
LOW PROFILE CONCRETE BARRIER (LPCB)
16"
DELINEATION OF END TREATMENTS
BARRIER REFLECTORS FOR CONCRETE TRAFFIC BARRIER AND ATTENUATORS
treatments and manufacturers.
the CWZTCD List for approved end
Highway Research Report 350. Refer to
as defined in the National Cooperative
zones shall meet crashworthy standards
End treatments used on CTB's in work
END TREATMENTS FOR
CTB'S USED
IN WORK ZONES
WARNING LIGHTS
1. Warning lights shall meet the requirements of the TMUTCD.
2. Warning lights shall NOT be installed on barricades.
3. Type A-Low Intensity Flashing Warning Lights are commonly used with drums. They are intended to warn of or mark a potentially hazardous
4. Type-C and Type D 360 degree Steady Burn Lights are intended to be used in a series for delineation to supplement other traffic control
devices. Their use shall be as indicated on this sheet and/or other sheets of the plans by the designation "SB".
5. The Engineer/Inspector or the plans shall specify the location and type of warning lights to be installed on the traffic control devices.
6. When required by the Engineer, the Contractor shall furnish a copy of the warning lights certification. The warning light manufacturer will
certify the warning lights meet the requirements of the latest ITE Purchase Specifications for Flashing and Steady-Burn Warning Lights.
WARNING LIGHTS MOUNTED ON PLASTIC DRUMS
1. Type A flashing warning lights are intended to warn drivers that they are approaching or are in a potentially hazardous area.
2. Type A random flashing warning lights are not intended for delineation and shall not be used in a series.
3. A series of sequential flashing warning lights placed on channelizing devices to form a merging taper may be used for delineation. If used,
the successive flashing of the sequential warning lights should occur from the beginning of the taper to the end of the merging taper in
order to identify the desired vehicle path. The rate of flashing for each light shall be 65 flashes per minute, plus or minus 10 flashes.
4. Type C and D steady-burn warning lights are intended to be used in a series to delineate the edge of the travel lane on detours, on lane
changes, on lane closures, and on other similar conditions.
5. Type A, Type C and Type D warning lights shall be installed at locations as detailed on other sheets in the plans.
6. Warning lights shall not be installed on a drum that has a sign, chevron or vertical panel.
7. The maximum spacing for warning lights on drums should be identical to the channelizing device spacing.
1. A warning reflector or approved substitute may be mounted on a plastic drum as a substitute for a Type C, steady burn warning light at the
discretion of the Contractor unless otherwise noted in the plans.
2. The warning reflector shall be yellow in color and shall be manufactured using a sign substrate approved for use with plastic drums listed
on the CWZTCD.
3. The warning reflector shall have a minimum retroreflective surface area (one-side) of 30 square inches.
4. Round reflectors shall be fully reflectorized, including the area where attached to the drum.
5. Square substrates must have a minimum of 30 square inches of reflectorized sheeting. They do not have to be reflectorized where it
attaches to the drum.
6. The side of the warning reflector facing approaching traffic shall have sheeting meeting the color and retroreflectivity requirements for
7. When used near two-way traffic, both sides of the warning reflector shall be reflectorized.
8. The warning reflector should be mounted on the side of the handle nearest approaching traffic.
9. The maximum spacing for warning reflectors should be identical to the channelizing device spacing requirements.
WARNING REFLECTORS MOUNTED ON PLASTIC DRUMS AS A SUBSTITUTE FOR TYPE C (STEADY BURN) WARNING LIGHTS
Reflectors
Barrier
3. Where traffic is on one side of the CTB, two (2) Barrier Reflectors
shall be mounted in approximately the midsection of each section of CTB.
An alternate mounting location is uniformly spaced at one end of each
CTB. This will allow for attachment of a barrier grapple without
damaging the reflector. The Barrier Reflector mounted on the side of
the CTB shall be located directly below the reflector mounted on top of
the barrier, as shown in the detail above.
4. Where CTB separates two-way traffic, three barrier reflectors shall be
mounted on each section of CTB. The reflector unit on top shall have
two yellow reflective faces (Bi-Directional)while the reflectors on each
side of the barrier shall have one yellow reflective face, as shown in
the detail above.
5. When CTB separates traffic traveling in the same direction, no barrier
reflectors will be required on top of the CTB.
6. Barrier Reflector units shall be yellow or white in color to match
the edgeline being supplemented.
7. Maximum spacing of Barrier Reflectors is forty (40) feet.
8. Pavement markers or temporary flexible-reflective roadway marker tabs
shall NOT be used as CTB delineation.
9. Attachment of Barrier Reflectors to CTB shall be per manufacturer's
recommendations.
10.Missing or damaged Barrier Reflectors shall be replaced as directed
by the Engineer.
11.Single slope barriers shall be delineated as shown on the above detail.
See D & OM (VIA)
recommendations.
as per manufacturer's
3 Barrier Reflectors
Install a minimum of
TRUCK-MOUNTED ATTENUATORS
Type C Warning Light or
approved substitute mounted on a
drum adjacent to the travel way.
4. The Flashing Arrow Board should be able to display the following symbols:
control devices that should be used in conjunction with the Flashing Arrow Board.
3. The Engineer/Inspector shall choose all appropriate signs, barricades and/or other traffic
or work on shoulders unless the "CAUTION" display (see detail below) is used.
2. Flashing Arrow Boards should not be used on two-lane, two-way roadways, detours, diversions
moving maintenance or construction activities on the travel lanes.
1. The Flashing Arrow Board should be used for all lane closures on multi-lane roadways, or slow
to bottom of panel.
14. Minimum mounting height of trailer mounted Arrow Boards should be 7 feet from roadway
flash rate and dimming requirements on this sheet for the same size arrow.
13. A full matrix PCMS may be used to simulate a Flashing Arrow Board provided it meets visibility,
12. A Flashing Arrow Board SHALL NOT BE USED to laterally shift traffic.
11. The Flashing Arrow Board shall be mounted on a vehicle, trailer or other suitable support.
display may be used during daylight operations.
10. The flashing arrow display is the TxDOT standard; however, the sequential Chevron
9. The sequential arrow display is NOT ALLOWED.
intervals of 25 percent for each sequential phase of the flashing chevron.
8. Minimum lamp "on time" shall be approximately 50 percent for the flashing arrow and equal
The flashing rate of the lamps shall not be less than 25 nor more than 40 flashes per minute.
7. The Flashing Arrow Board shall be capable of minimum 50 percent dimming from rated lamp voltage.
6. The straight line caution display is NOT ALLOWED.
Diamond Caution mode as shown.
5. The "CAUTION" display consists of four corner lamps flashing simultaneously, or the Alternating
REQUIREMENTS
C 48 x 96 15 1 mile
B 30 x 60 13 3/4 mile
MINIMUM
TRAFFIC BARRIER OR GUARDRAIL.
ARROW BOARD BEHIND CONCRETE
RIGHT-OF-WAY OR PLACE THE
THE ARROW BOARD FROM THE
WHEN NOT IN USE, REMOVE
shall be equipped with
automatic dimming devices.
Flashing Arrow Boards
devices placed perpendicular to traffic on the upstream side of traffic.
taper or merging taper, otherwise they shall be delineated with four (4) channelizing
Arrow Boards may be located behind channelizing devices in place for a shoulder
ATTENTION
LEFT & RIGHT
CHEVRON ARROWLEFT & RIGHT
ALTERNATING DIAMOND CAUTION
DOUBLE ARROW
OR
4 CORNER CAUTION
FLASHING ARROW BOARDS
16" tall plastic bracket
Barrier Reflector on
manufacturer's recommendations.
Attach the delineators as per
reflectors is 20 feet.
Max. spacing of barrier
extended distance from the TMA.
area is spread down the roadway and the work crew is an
6. The only reason a TMA should not be required is when a work
without adversely affecting the work performance.
30 to 100 feet in advance of the area of crew exposure
5. A TMA should be used anytime that it can be positioned
in the plans.
4. TMAs are required on freeways unless otherwise noted
3. Refer to the CWZTCD for a list of approved TMAs.
Level 3 TMAs.
2. Refer to the CWZTCD for the requirements of Level 2 or
or the Manual for Assessing Safety Hardware (MASH).
Cooperative Highway Research Report No. 350 (NCHRP 350)
must meet the requirements outlined in the National
1. Truck-mounted attenuators (TMA) used on TxDOT facilities
8. The location of warning lights and warning reflectors on drums shall be as shown elsewhere in the plans.
7. When used to delineate curves, Type-C and Type D Steady Burn Lights should only be placed on the outside of the curve, not the inside.
DMS 8300-Type B or Type C.
FL FL
1. Barrier Reflectors shall be pre-qualified, and conform to the color and
reflectivity requirements of DMS-8600. A list of prequalified Barrier
Reflectors can be found at the Material Producer List web address
shown on BC(1).
2. Color of Barrier Reflectors shall be as specified in the TMUTCD. The
cost of the reflectors shall be considered subsidiary to Item 512.
SHEET 7 OF 12
Standard
Division
Operations
Traffic
30
SHEET 8 OF 12
7-13
CHANNELIZING DEVICES
BARRICADE AND CONSTRUCTION
FILE:DATE:102
Standard
Division
Operations
Traffic
Pre-qualified plastic drums shall meet the following requirements:of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER: affect their appearance or serviceability.
BC(8)-14
8-14
DN:CK:DW:CK:FILE:
---
-
JOB
COUNTY
SECT
DIST
REVISIONS
TxDOT TxDOT TxDOT TxDOT
-
HIGHWAY
-
SHEET NO.
C TxDOT
CONT
bc-14.dgn
November 2002 $FILE$$DATE$$TIME$4-03
9-07
mount with diagonals
sloping down towards
travel way
(Maximum Sign Dimension)
18" x 24" Sign
1. For long term stationary work zones on freeways, drums shall be used as
the primary channelizing device.
2. For intermediate term stationary work zones on freeways, drums should be
used as the primary channelizing device but may be replaced in tangent
sections by vertical panels, or 42" two-piece cones. In tangent sections
if personnel are present on the project at all times to maintain the
cones in proper position and location.
3. For short term stationary work zones on freeways, drums are the preferred
approved by the Engineer.
4. Drums and all related items shall comply with the requirements of the
current version of the "Texas Manual on Uniform Traffic Control Devices"
(TMUTCD) and the "Compliant Work Zone Traffic Control Devices List"
(CWZTCD).
5. Drums, bases, and related materials shall exhibit good workmanship and
shall be free from objectionable marks or defects that would adversely
6. The Contractor shall have a maximum of 24 hours to replace any plastic
drums identified for replacement by the Engineer/Inspector. The replace-
ment device must be an approved device.
1. Plastic drums shall be a two-piece design; the "body" of the drum shall
be the top portion and the "base" shall be the bottom.
2. The body and base shall lock together in such a manner that the body
separates from the base when impacted by a vehicle traveling at a speed
of 20 MPH or greater but prevents accidental separation due to normal
handling and/or air turbulence created by passing vehicles.
3. Plastic drums shall be constructed of lightweight flexible, and
deformable materials. The Contractor shall NOT use metal drums or
single piece plastic drums as channelization devices or sign supports.
4. Drums shall present a profile that is a minimum of 18 inches in width
at the 36 inch height when viewed from any direction. The height of
drum unit (body installed on base) shall be a minimum of 36 inches and
a maximum of 42 inches.
5. The top of the drum shall have a built-in handle for easy pickup and
shall be designed to drain water and not collect debris. The handle
shall have a minimum of two widely spaced 9/16 inch diameter holes to
allow attachment of a warning light, warning reflector unit or approved
compliant sign.
6. The exterior of the drum body shall have a minimum of four alternating
orange and white retroreflective circumferential stripes not less than
4 inches nor greater than 8 inches in width. Any non-reflectorized
space between any two adjacent stripes shall not exceed 2 inches in
width.
7. Bases shall have a maximum width of 36 inches, a maximum height of 4
inches, and a minimum of two footholds of sufficient size to allow base
to be held down while separating the drum body from the base.
8. Plastic drums shall be constructed of ultra-violet stabilized, orange,
high-density polyethylene (HDPE) or other approved material.
Chevron CW1-8, Opposing Traffic Lane
Divider, Driveway sign D70a, Keep Right
channelizing device but may be replaced in tapers, transitions and tangent
one-piece cones may be used with the approval of the Engineer but only
1. Signs used on plastic drums shall be manufactured using
substrates listed on the CWZTCD.
2. Chevrons and other work zone signs with an orange background
3. Vertical Panels shall be manufactured with orange and white
4. Other sign messages (text or symbolic) may be used as
approved by the Engineer. Sign dimensions shall not exceed
5. Signs shall be installed using a 1/2 inch bolt (nominal)
and nut, two washers, and one locking washer for each
connection.
6. Mounting bolts and nuts shall be fully engaged and
adequately torqued. Bolts should not extend more than 1/2
inch beyond nuts.
7. Chevrons may be placed on drums on the outside of curves,
on merging tapers or on shifting tapers. When used in these
locations they may be placed on every drum or spaced not
more than on every third drum. A minimum of three (3)
should be used at each location called for in the plans.
approval of the Engineer.
8. R9-9, R9-10, R9-11 and R9-11a Sidewalk Closed signs which
are 24 inches wide may be mounted on plastic drums, with
Vertical Panel
12" x 24"
ON PLASTIC DRUMS
SIGNS, CHEVRONS, AND VERTICAL PANELS MOUNTED
by Engineer
R4 series or other signs as approved
GENERAL DESIGN REQUIREMENTS
GENERAL NOTES
1. The stripes used on drums shall be constructed of sheeting meeting the
1. Unballasted bases shall be large enough to hold up to 50 lbs. of sand.
This base, when filled with the ballast material, should weigh between
35 lbs (minimum) and 50 lbs (maximum). The ballast may be sand in one
to three sandbags separate from the base, sand in a sand-filled plastic
base, or other ballasting devices as approved by the Engineer. Stacking
of sandbags will be allowed, however height of sandbags above pavement
surface may not exceed 12 inches.
2. Bases with built-in ballast shall weigh between 40 lbs. and 50 lbs.
Built-in ballast can be constructed of an integral crumb rubber base or
a solid rubber base.
would become hazardous to motorists, pedestrians, or workers when the
drum is struck by a vehicle.
holes in the bottoms so that water will not collect and freeze becoming
a hazard when struck by a vehicle.
color and retroreflectivity requirements of Departmental Materials
2. The sheeting shall be suitable for use on and shall adhere to the drum
surface such that, upon vehicular impact, the sheeting shall remain
adhered in-place and exhibit no delaminating, cracking, or loss of
retroreflectivity other than that loss due to abrasion of the sheeting
surface.
24"
36"8"
12"
4" White
4" Orange
45o
CW1-6L
18" minHandle
36" min42" max4" max
4" max(typ)
8" max
4" min
(typ.)
2" max
dia. max)
Base (36"
drums
minimum of 5
for stacking a
Taper to allow
debris
of water or
allow collection
Top should not
warning lights
signs and
for mounting
9/16" dia. (typ)
DIRECTION INDICATOR BARRICADE DETECTABLE PEDESTRIAN BARRICADES
BALLAST
RETROREFLECTIVE SHEETING
10.Drum and base shall be marked with manufacturer's name and model number.
sections by vertical panels, two-piece cones or one-piece cones as
plastic drums
substrates shall NOT be used on
Plywood, Aluminum or Metal sign
36"
Barricades
Detectable Pedestrian
providers of approved
and the CWZTCD list for
for fabrication. See note 3
This detail is not intended
rail for hand trailing
Continuous smooth
Detectable Edge
2" Max.
trailing with no splinters, burrs, or sharp edges.
rail provides a smooth continuous rail suitable for hand
barricade rails as shown on BC(10) provided that the top
6. Detectable pedestrian barricades may use 8" nominal
barricades.
5. Warning lights shall not be attached to detectable pedestrian
as a control for pedestrian movements.
for Buildings and Facilities (ADAAG)" and should not be used
"Americans with Disabilities Act Accessibility Guidelines
detectable, do not comply with the design standards in the
4. Tape, rope, or plastic chain strung between devices are not
path.
detectable edging can satisfactorily delineate a pedestrian
barriers, and wood or chain link fencing with a continuous
above, longitudinal channelizing devices, some concrete
3. Detectable pedestrian barricades similar to the one pictured
shall be placed across the full width of the closed sidewalk.
with a visual disability traveling with the aid of a long cane
closed sidewalk, a device that is detectable by a person
2. Where pedestrians with visual disabilities normally use the
the features present in the existing pedestrian facility.
detectable and include accessibility features consistent with
relocated in a TTC zone, the temporary facilities shall be
1. When existing pedestrian facilities are disrupted, closed, or
9. Drum body shall have a maximum unballasted weight of 11 lbs.
for this type of ballast on the CWZTCD list.
3. Recycled truck tire sidewalls may be used for ballast on drums approved
4. The ballast shall not be heavy objects, water, or any material that
5. When used in regions susceptible to freezing, drums shall have drainage
6. Ballast shall not be placed on top of drums.
7. Adhesives may be used to secure base of drums to pavement.
series signs discussed in note 8 below.
18 inches in width or 24 inches in height, except for the R9
Specification DMS-8300, "Sign Face Materials." Type A reflective
sheeting shall be supplied unless otherwise specified in the plans.
FL
the intended traveled lane.
Diagonal stripes on Vertical Panels shall slope down toward
sheeting meeting the requirements of DMS-8300 Type A
FL
Ballast shall be as approved by the manufacturers instructions.
5. Approved manufacturers are shown on the CWZTCD List.
allowed.
4. Double arrows on the Direction Indicator Barricade will not be
shall be as per DMS 8300.
45 degrees in the direction road users are to pass. Sheeting types
white and orange stripes sloping downward at an angle of
above a rail with Type A retroreflective sheeting in alternating 4"
on a background of Type B or Type C Orange retroreflective sheeting
Large Arrow (CW1-6) sign in the size shown with a black arrow
3. The Direction Indicator Barricade shall consist of One-Direction
the intended travel lane.
in series to direct the driver through the transition and into
2. If used, the Direction Indicator Barricade should be used
guidance to drivers is necessary.
transitions, and other areas where specific directional
1. The Direction Indicator Barricade may be used in tapers,
FL
FL
specified in the plans.
of DMS-8300, "Sign Face Material," unless otherwise
sheeting meeting the color and retroreflectivity requirements
shall be manufactured with Type B or Type C Orange
being orange.
with the top stripe
reflective sheeting
using Type A retro-
and 2 white stripes
a minimum of 2 orange
Each drum shall have
31
SHEET 9 OF 12
Min.
18"
12"
note 7
See
note 7
See
note 7
See
CHEVRONS
VERTICAL PANELS (VPs)
HOLLOW OR WATER BALLASTED SYSTEMS USED AS
LONGITUDINAL CHANNELIZING DEVICES OR BARRIERSOPPOSING TRAFFIC LANE DIVIDERS (OTLD)
MINIMUM DESIRABLE TAPER LENGTHS
CHANNELIZING DEVICES AND
SUGGESTED MAXIMUM SPACING OF
7. Where the height of reflective material on the vertical
6 inches shall be used.
panel is 36 inches or greater, a panel stripe of
4. VP's used on expressways and freeways or other high
7-13
CHANNELIZING DEVICES
BARRICADE AND CONSTRUCTION
DN:CK:DW:CK:FILE:
JOB
COUNTY
SECT
DIST
REVISIONS
TxDOT TxDOT TxDOT TxDOT
HIGHWAY
SHEET NO.
C TxDOT
BC(9)-14
CONT
bc-14.dgn
November 2002
103
Standard
Division
Operations
Traffic
9-07
LCD along the full length of the device.
sheeting meeting the requirements for barricade rails as shown on BC(10) placed near the top of the
6. LCDs used as barricades placed perpendicular to traffic should have at least one row of reflective
on BC(7) when placed roughly parallel to the travel lanes.
5. LCDs shall be supplemented with retroreflective delineation as required for temporary barriers
8-14
---
--
- of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:FILE:DATE:$FILE$$DATE$$TIME$24" min.36" min. distance above travel way45
VP-1L VP-1R
o
45o
36"
12"
36"
18"
18"
4"
4"
4"
4"
4"
4"
4"
4"
4"
DRIVEABLE
PORTABLE
FIXED
(Rigid or self-righting)
(Rigid or self-righting)
1. Work Zone channelizing devices illustrated on this sheet may be installed
in close proximity to traffic and are suitable for use on high or low
speed roadways. The Engineer/Inspector shall ensure that spacing and
placement is uniform and in accordance with the "Texas Manual on Uniform
Traffic Control Devices" (TMUTCD).
2. Channelizing devices shown on this sheet may have a driveable, fixed or
portable base. The requirement for self-righting channelizing devices must
be specified in the General Notes or other plan sheets.
3. Channelizing devices on self-righting supports should be used in work zone
areas where channelizing devices are frequently impacted by errant vehicles
or vehicle related wind gusts making alignment of the channelizing devices
difficult to maintain. Locations of these devices shall be detailed else-
where in the plans. These devices shall conform to the TMUTCD and the
"Compliant Work Zone Traffic Control Devices List" (CWZTCD).
damaged, nonreflective, faded, or broken devices and bases as required by
the Engineer/Inspector. The Contractor shall be required to maintain proper
device spacing and alignment.
5. Portable bases shall be fabricated from virgin and/or recycled rubber. The
6. Pavement surfaces shall be prepared in a manner that ensures proper bonding
between the adhesives, the fixed mount bases and the pavement surface.
Adhesives shall be prepared and applied according to the manufacturer's
recommendations.
7. The installation and removal of channelizing devices shall not cause
detrimental effects to the final pavement surfaces, including pavement
permitted on final pavement surfaces. The Engineer/Inspector shall approve
all application and removal procedures of fixed bases.
1. Opposing Traffic Lane Dividers (OTLD) are
delineation devices designed to convert a
normal one-way roadway section to two-way
operation. OTLD's are used on temporary
centerlines. The upward and downward arrows
on the sign's face indicate the direction of
traffic on either side of the divider. The
3. Spacing between the OTLD shall not exceed 500
the OTLD's should not exceed 100 foot spacing.
4. The OTLD shall be orange with a black non-
reflective legend. Sheeting for the OTLD shall
1. The chevron shall be a vertical rectangle with a
minimum size of 12 by 18 inches.
2. Chevrons are intended to give notice of a sharp
change of alignment with the direction of travel
and provide additional emphasis and guidance for
vehicle operators with regard to changes in
horizontal alignment of the roadway.
3. Chevrons, when used, shall be erected on the out-
side of a sharp curve or turn, or on the far side
of an intersection. They shall be in line with
and at right angles to approaching traffic.
Spacing should be such that the motorist always
has three in view, until the change in alignment
eliminates its need.
4. To be effective, the chevron should be visible
for at least 500 feet.
5. Chevrons shall be orange with a black nonreflec-
tive legend. Sheeting for the chevron shall be
6. For Long Term Stationary use on tapers or
transitions on freeways and divided highways
self-righting chevrons may be used to supplement
plastic drums but not to replace plastic drums.
4. The Contractor shall maintain devices in a clean condition and replace
surface discoloration or surface integrity. Driveable bases shall not be
1. Vertical Panels (VP's) are normally used to channelize
traffic or divide opposing lanes of traffic.
2. VP's may be used in daytime or nighttime situations.
They may be used at the edge of shoulder drop-offs and
other areas such as lane transitions where positive
daytime and nighttime delineation is required. The
Engineer/Inspector shall refer to the Roadway Design
Manual Appendix B "Treatment of Pavement Drop-offs in
Work Zones" for additional guidelines on the use of
VP's for drop-offs.
3. VP's should be mounted back to back if used at the edge
of cuts adjacent to two-way two lane roadways. Stripes
are to be reflective orange and reflective white and
should always slope downward toward the travel lane.
of retroreflective area facing traffic.
5. Self-righting supports are available with portable base.
See "Compliant Work Zone Traffic Control Devices List"
(CWZTCD).
CW6-4
8" to 12"8" to 12"8" to 12"8" to 12"
8" to 12"
WATER BALLASTED SYSTEMS USED AS BARRIERS
1. Water ballasted systems used as barriers shall not be used solely to channelize road users, but also to protect the
work space per the appropriate NCHRP 350 crashworthiness requirements based on roadway speed and barrier application.
2. Water ballasted systems used to channelize vehicular traffic shall be supplemented with retroreflective delineation
or channelizing devices to improve daytime/nighttime visibility. They may also be supplemented with pavement markings.
3. Water ballasted systems used as barriers shall be placed in accordance to application and installation requirements
specific to the device, and used only when shown on the CWZTCD list.
4. Water ballasted systems used as barriers should not be used for a merging taper except in low speed (less than 45 MPH)
urban areas. When used on a taper in a low speed urban area, the taper shall be delineated and the taper length
should be designed to optimize road user operations considering the available geometric conditions.
5. When water ballasted systems used as barriers have blunt ends exposed to traffic, they should be attenuated
Surface
Roadway
Base
Mount
Surface
min.
24"
min.
24"
Adhesive
w/ Approved
Fixed Base
depth
embedment
12" minimum
min.
36"
Support
Self-righting
Support
Rigid
Support can be used)
(Driveable Base, or Flexible
Fixed Base w/ Approved Adhesive
on drums.
mounted
or may be
may be used,
Driveable Base
Fixed or
Portable,
back to back
mounted
Panels
speed roadways, may have more than 270 square inches
unless noted otherwise.
conforming to Departmental Material Specification DMS-8300,
GENERAL NOTES
Taper lengths have been rounded off.
S=Posted Speed (MPH)
L=Length of Taper (FT.) W=Width of Offset (FT.) **
2
***
75 750'
720'
825'900'75'
60'
70'
80'
90'
100'
110'
120'
130'
140'
150'
30'
35'
40'
45'
50'
55'
60'
65'
70'
150'
205'
265'
450'
500'
550'
600'
165'
225'
295'
495'
550'
605'
660'
180'
320'
600'
660'
650'715'780'
245'
540'
700'770'840'
30
35
40
45
50
55
60
65
70
60
WSL=
Posted
Speed
On a
Tangent
On a
Taper
12'
OffsetOffset
11'
Offset
10'
Minimum
Desirable
Taper Lengths
Suggested Maximum
Spacing of
Channelizing
Devices
Formula
L=WS
80 800'880'960'80'160'
LONGITUDINAL CHANNELIZING DEVICES (LCD)
2. LCDs may be used instead of a line of cones or drums.
used only when shown on the CWZTCD list.
3. LCDs shall be placed in accordance to application and installation requirements specific to the device, and
4. LCDs should not be used to provide positive protection for obstacles, pedestrians or workers.
connected together. They are not designed to contain or redirect a vehicle on impact.
1. LCDs are crashworthy, lightweight, deformable devices that are highly visible, have good target value and can be
adhesive or rubber weight to minimize movement
base is secured to the pavement with an
caused by a vehicle impact or wind gust.
portable bases shall weigh a minimum of 30 lbs.
6. Sheeting for the VP's shall be retroreflective Type A
FL
FL
as per manufacturer recommendations or flared to a point outside the clear zone.
of the unit shall not be less than 32 inches in height.
systems must have a continuous detectable bottom for users of long canes and the top
If used to channelize pedestrians, longitudinal channelizing devices or water ballasted
2. The OTLD may be used in combination with 42"
cones or VPs.
feet. 42" cones or VPs placed between
the requirements of DMS-8300.
unless noted otherwise. The legend shall meet
to Departmental Material Specification DMS-8300,
be retroreflective Type B or Type C conforming FL
requirements of DMS-8300.
unless noted otherwise. The legend shall meet the
Departmental Material Specification DMS-8300,
retroreflective Type B or Type C conforming to FL
32
SHEET 10 OF 12
7-13
PROJECTS LET AFTER MARCH 2014.
THIS DEVICE SHALL NOT BE USED ON
BC(10)-14
CHANNELIZING DEVICES
BARRICADE AND CONSTRUCTIONof this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:FILE:DATE:
to Departmental Material Specification DMS-8300 unless otherwise noted.
9. Sheeting for barricades shall be retroreflective Type A conforming
for details of the Type 3 Barricades and a list of all materials
used in the construction of Type 3 Barricades.
8-14
DN:CK:DW:CK:FILE:
---
-
JOB
COUNTY
SECT
DIST
REVISIONS
TxDOT TxDOT TxDOT TxDOT
-
HIGHWAY
-
SHEET NO.
C TxDOT
CONT
bc-14.dgn
November 2002 $FILE$$DATE$$TIME$104
9-07
2" max.3"-4"
1. Where positive redirectional
2. Plastic construction fencing
safety as required in the plans.
3. Vertical Panels on flexible support
capability is provided, drums
may be omitted.SB
SB
SB
SB
6" min.
4" min.
3" min.
3" min.
may be used with drums for
may be omitted if drums are used.
Detour
Roadway
R11-2
M4-10L DETOUR
ROAD
CLOSED
NAME
ADDRESS
CITY
STATE
CONTRACTOR
30 feet
2" min.
3"-4"
6" min.
4" min.
2" min.
shoulder width is less than 4 feet.
than 12 feet, steady-burn lights
42"
4"
4"
4"
4"
2"
2"
2"EDGELINE
CHANNELIZER
PLAN VIEW
PLAN VIEW
2. Advance signing shall be as specified elsewhere in the plans.
PERSPECTIVE VIEW
PERSPECTIVE VIEW
3"-4"
2" min.
10'
may be substituted for drums when the
4. When the shoulder width is greater
1. This device is intended only for use in place of a vertical panel to
2" min.
2" min.
4" min. orange
4" min. white
4" min. orange
4" min. white
Drums, vertical panels or 42" cones
STOCKPILE
channelize traffic by indicating the edge of the travel lane. It is
not intended to be used in transitions or tapers.
2. This device shall not be used to separate lanes of traffic (opposing
or otherwise) or warn of objects.
3. This device is based on a 42 inch, two-piece cone with an alternate
striping pattern: four 4 inch retroreflective bands, with an
approximate 2 inch gap between bands. The color of the band should
correspond to the color of the edgeline (yellow for left edgeline,
white for right edgeline) for which the device is substituted or for
which it supplements. The reflectorized bands shall be retroreflective
at 50' maximum spacing
omitted here
or barricade may be
downstream drums
On one-way roads
within 30' from travel lane.
should be used when stockpile is
Channelizing devices parallel to traffic
Two-Piece cones One-Piece cones Tubular Marker
G20-6T
SB
CONES
3" to 4"
2" to 6"
Alternate
Alternate
clear zone.
is outside
stockpile location
Desirable
Plastic Drum
Typical
min.
28"
min.
28"
min.
28"min.
42"
on one-way roadway
are not required
These drums
barricaded in the same manner.
divided highway shall be
Each roadway of a
and maximum of 4 drums)
width makes it necessary. (minimum of 2
side of approaching traffic if the crown
Increase number of plastic drums on the
be used across the work area.A minimum of two drums shall50'
Approx.
50'
Approx.
1. Refer to the Compliant Work Zone Traffic Control Devices List (CWZTCD)
projects closed to all traffic.
3. Barricades extending across a roadway should have stripes that slope
downward in the direction toward which traffic must turn in detouring.
When both right and left turns are provided, the chevron striping may
slope downward in both directions from the center of the barricade.
Where no turns are provided at a closed road striping should slope
downward in both directions toward the center of roadway.
4. Striping of rails, for the right side of the roadway, should slope
downward to the left. For the left side of the roadway, striping
should slope downward to the right.
5. Identification markings may be shown only on the back of the
barricade rails. The maximum height of letters and/or company logos
used for identification shall be 1".
6. Barricades shall not be placed parallel to traffic unless an adequate
clear zone is provided.
7. Warning lights shall NOT be installed on barricades.
8. Where barricades require the use of weights to keep from turning over,
the use of sandbags with dry, cohesionless sand is recommended. The
sandbags will be tied shut to keep the sand from spilling and to
maintain a constant weight. Sand bags shall not be stacked in a manner
that covers any portion of a barricade rails reflective sheeting.
Rock, concrete, iron, steel or other solid objects will NOT be
permitted. Sandbags should weigh a minimum of 35 lbs and a maximum of
50 lbs. Sandbags shall be made of a durable material that tears upon
vehicular impact. Rubber (such as tire inner tubes) shall not be used
for sandbags. Sandbags shall only be placed along or upon the base
supports of the device and shall not be suspended above ground level
or hung with rope, wire, chains or other fasteners.
be used as a sign support.
Barricades shall NOT 10' max.10' max.10' max.4. The base must weigh a minimum of 30 lbs.
or yellow warning reflector
Steady burn warning light
or yellow warning reflector
Plastic drum with steady burn light
Plastic drum
LEGEND
of the culvert widening.
5. Drums must extend the length
30 lbs. including base.
42" 2-piece cones shall have a minimum weight of
28" Cones shall have a minimum weight of 9 1/2 lbs.
CULVERT WIDENING OR OTHER ISOLATED WORK WITHIN THE PROJECT LIMITS
TRAFFIC CONTROL FOR MATERIAL STOCKPILES
TYPICAL PANEL DETAIL
FOR SKID OR POST TYPE BARRICADES
TYPICAL STRIPING DETAIL FOR BARRICADE RAIL
8' max. length Type 3 Barricades
downward in the direction of detour.
Barricade striping should slant
for two-way traffic.
facing one-way traffic and both sides
reflective white stripes on one side
shall be reflectorized orange and
The three rails on Type 3 barricades
barricade
or 1 Type 3
Min. 2 drums
barricade
or 1 Type 3
Min. 2 drums
TYPE 3 BARRICADES
2. Type 3 Barricades shall be used at each end of construction
TYPE 3 BARRICADE (POST AND SKID) TYPICAL APPLICATION
minimum of 10 feet behind Type 3 Barricades.
mounting height in center of roadway. The signs should be a
1. Signs should be mounted on independent supports at a 7 foot
1. Traffic cones and tubular markers shall be predominantly orange, and
meet the height and weight requirements shown above.
2. One-piece cones have the body and base of the cone molded in one consolidated
unit. Two-piece cones have a cone shaped body and a separate rubber base,
or ballast, that is added to keep the device upright and in place.
height shown, in order to aid in retrieving the device.
3. Two-piece cones may have a handle or loop extending up to 8" above the minimum
reflective bands as shown above. The reflective bands shall have a smooth, sealed
7. Cones or tubular markers used on each project should be of the same size
and shape.
to maintain them in their proper upright position.
for intermediate-term or long-term stationary work unless personnel is on-site
short-term stationary work as defined on BC(4). These should not be used
5. 28" cones and tubular markers are generally suitable for short duration and
durations.
6. 42" two-piece cones, vertical panels or drums are suitable for all work zone
4. Cones or tubular markers used at night shall have white or white and orange
DMS-8300 Type A.
outer surface and meet the requirements of Departmental Material Specification
unless otherwise noted.
Type A conforming to Departmental Material Specification DMS-8300,
45o
6"6"7 inches.
Sheeting
Reflective
Width of
Minimum
nominal
8"
Standard
Division
Operations
Traffic20"20"48"Flat rail
Stiffener
2 stiffeners shall be allowed on one barricade.
Stiffener may be inside or outside of support, but no more than
4' min., 8' max.
33
SHEET 11 OF 12
7-13
PAVEMENT MARKINGS
BARRICADE AND CONSTRUCTION
DN:CK:DW:CK:FILE:
JOB
COUNTY
SECT
DIST
REVISIONS
TxDOT TxDOT TxDOT TxDOT
HIGHWAY
SHEET NO.
C TxDOT
BC(11)-14
CONT
bc-14.dgn
February 1998
105
Standard
Division
Operations
Traffic
9-07
11-02
1-02
2-98
8-14
---
--
-
of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:FILE:DATE:$FILE$$DATE$$TIME$TOP VIEW FRONT VIEW SIDE VIEW
Adhesive pad
4"+ ‚"
2"
GENERAL REMOVAL OF PAVEMENT MARKINGS
1. The Contractor shall be responsible for maintaining work zone and
within the CSJ limits unless otherwise stated in the plans.
2. Color, patterns and dimensions shall be in conformance with the
"Texas Manual on Uniform Traffic Control Devices" (TMUTCD).
3. Additional supplemental pavement marking details may be found in the
plans or specifications.
4. Pavement markings shall be installed in accordance with the TMUTCD
and as shown on the plans.
5. When short term markings are required on the plans, short term
markings shall conform with the TMUTCD, the plans and details as
shown on the Standard Plan Sheet WZ(STPM).
6. When standard pavement markings are not in place and the roadway
is opened to traffic, DO NOT PASS signs shall be erected to mark
the beginning of the sections where passing is prohibited and
PASS WITH CARE signs at the beginning of sections where passing
is permitted.
7. All work zone pavement markings shall be installed in accordance
with Item 662, "Work Zone Pavement Markings."
RAISED PAVEMENT MARKERS
1. Raised pavement markers are to be placed according to the patterns
on BC(12).
2. All raised pavement markers used for work zone markings shall meet
PREFABRICATED PAVEMENT MARKINGS
1. Removable prefabricated pavement markings shall meet the requirements
of DMS-8241.
2. Non-removable prefabricated pavement markings (foil back) shall meet
the requirements of DMS-8240.
MAINTAINING WORK ZONE PAVEMENT MARKINGS
1. The Contractor will be responsible for maintaining work zone pavement
markings within the work limits.
2. Work zone pavement markings shall be inspected in accordance with
the frequency and reporting requirements of work zone traffic control
device inspections as required by Form 599.
3. The markings should provide a visible reference for a minimum
distance of 300 feet during normal daylight hours and 160 feet when
illuminated by automobile low-beam headlights at night, unless sight
distance is restricted by roadway geometrics.
4. Markings failing to meet this criteria within the first 30 days after
placement shall be replaced at the expense of the Contractor as per
Specification Item 662.
days, where flaggers and/or sufficient channelizing devices are used
in lieu of markings to outline the detour route.
3. Pavement markings shall be removed to the fullest extent possible,
so as not to leave a discernable marking. This shall be by any method
approved by TxDOT Specification Item 677 for "Eliminating Existing
Pavement Markings and Markers".
4. The removal of pavement markings may require resurfacing or seal
5. Subject to the approval of the Engineer, any method that proves to be
successful on a particular type pavement may be used.
6. Blast cleaning may be used but will not be required unless specifically
7. Over-painting of the markings SHALL NOT BE permitted.
8. Removal of raised pavement markers shall be as directed by the
Engineer.
9. Removal of existing pavement markings and markers will be paid for
directly in accordance with Item 677, "ELIMINATING EXISTING PAVEMENT
MARKINGS AND MARKERS," unless otherwise stated in the plans.
10.Black-out marking tape may be used to cover conflicting existing
markings for periods less than two weeks when approved by the Engineer.
1. Temporary flexible-reflective roadway marker tabs used as guidemarks
shall meet the requirements of DMS-8242.
2. Tabs detailed on this sheet are to be inspected and accepted by the
Engineer or designated representative. Sampling and testing is not
normally required, however at the option of the Engineer, either "A"
or "B" below may be imposed to assure quality before placement on the
roadway.
B. Select five (5) tabs and perform the following test. Affix five
(5) tabs at 24 inch intervals on an asphaltic pavement in a
straight line. Using a medium size passenger vehicle or pickup,
run over the markers with the front and rear tires at a speed
of 35 to 40 miles per hour, four (4) times in each direction. No
more than one (1) out of the five (5) reflective surfaces shall
be lost or displaced as a result of this test.
3. Small design variances may be noted between tab manufacturers.
4. See Standard Sheet WZ(STPM) for tab placement on new pavements. See
1. Raised pavement markers used as guidemarks shall be from the approved
product list, and meet the requirements of DMS-4200.
3. Adhesive for guidemarks shall be bituminous material hot applied or
butyl rubber pad for all surfaces, or thermoplastic for concrete
surfaces.
Guidemarks shall be designated as:
YELLOW - (two amber reflective surfaces with yellow body).
WHITE - (one silver reflective surface with white body).
Standard Sheet TCP(7-1) for tab placement on seal coat work.
TABS TO THE PAVEMENT SURFACE
TEMPORARY FLEXIBLE-REFLECTIVE ROADWAY MARKER
STAPLES OR NAILS SHALL NOT BE USED TO SECURE
1/4" and less than 1".
is usually more than
Height of sheeting
WORK ZONE PAVEMENT MARKINGS Roadway Marker Tabs
Temporary Flexible-Reflective
DEPARTMENTAL MATERIAL SPECIFICATIONS
DMS-6130
EPOXY AND ADHESIVES DMS-6100
DMS-4300
DMS-8240
DMS-8241
DMS-8242
DMS-4200
TRAFFIC BUTTONS
PERMANENT PREFABRICATED PAVEMENT MARKINGS
PAVEMENT MARKINGS
TEMPORARY REMOVABLE, PREFABRICATED
ROADWAY MARKER TABS
TEMPORARY FLEXIBLE, REFLECTIVE
A list of prequalified reflective raised pavement markers,
non-reflective traffic buttons, roadway marker tabs and other
pavement markings can be found at the Material Producer List
web address shown on BC(1).
BITUMINOUS ADHESIVE FOR PAVEMENT MARKERS
PAVEMENT MARKERS (REFLECTORIZED)
RAISED PAVEMENT MARKERS USED AS GUIDEMARKS
project shall be of the same manufacturer.
2. All temporary construction raised pavement markers provided on a
the requirements of Item 672, "RAISED PAVEMENT MARKERS" and Departmental
Material Specification DMS-4200 or DMS-4300.
shown in the plans.
existing pavement markings, in accordance with the standard
specifications and special provisions, on all roadways open to traffic
1. Pavement markings that are no longer applicable, could create confusion
or direct a motorist toward or into the closed portion of the roadway
shall be removed or obliterated before the roadway is opened to traffic.
Section to determine specification compliance.
and submit to the Construction Division, Materials and Pavement
A. Select five (5) or more tabs at random from each lot or shipment
2. The above shall not apply to detours in place for less than three
coating portions of the roadway as described in Item 677.
34
SHEET 12 OF 12
7-13
PAVEMENT MARKING PATTERNS
BARRICADE AND CONSTRUCTIONof this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:FILE:DATE:8-14
BC(12)-14
DN:CK:DW:CK:FILE:
---
-
JOB
COUNTY
SECT
DIST
REVISIONS
TxDOT TxDOT TxDOT TxDOT
-
HIGHWAY
-
SHEET NO.
C TxDOT
CONT
bc-14.dgn
February 1998 $FILE$$DATE$$TIME$106
9-071-97
2-98
11-02
10 to 12"
PAVEMENT MARKING PATTERNS
Yellow
Yellow
White
White
Yellow
Yellow
Yellow
Type II-A-A Type II-A-A
Type Y buttons
Type Y buttons
Type II-A-A
Type II-A-A
Type I-A
Type I-A
Type W buttons
Type I-C
Type Y buttons
Type Y buttons
Type W buttons
Type I-C
Type I-C or II-C-R
Type I-C or II-C-R 10'30'
-
-
-
DISCOURAGE LANE CHANGING.)
EDGE LINE
OR SINGLE
Yellow
White
White or Yellow
White or Yellow
NO-PASSING LINE
WIDE
LINE
(FOR LEFT TURN CHANNELIZING LINE
OR CHANNELIZING LINE USED TO
Type Y buttons
Type I-C , I-A or II-A-A Type W or Y buttons
Type I-C Type W buttons
Type I-C or II-A-A
STANDARD WORK ZONE PAVEMENT MARKINGS DETAILS
Type II-A-A
REMOVABLE MARKINGS
WITH RAISED
PAVEMENT MARKERS
Type I-C or II-A-A
(when required)
Raised Pavement Markers
If raised pavement markers are used
to supplement REMOVABLE markings,
the markers shall be applied to the
top of the tape at the approximate
mid length of tape used for broken
60" + 3"
-REFLECTORIZED PAVEMENT MARKINGS - PATTERN B
REFLECTORIZED PAVEMENT MARKINGS - PATTERN A
REFLECTORIZED PAVEMENT MARKINGS
10 to 12"
4 to 8"6 to 8"
60" + 3"
60" + 3"
4"
4 to 12"
4 to 12"
4"
8"
1-2"
10'
10'30'
40' + 1'
5' + 6"
20' + 1'
30'
RAISED PAVEMENT MARKERS - PATTERN A
RAISED PAVEMENT MARKERS - PATTERN B
RAISED PAVEMENT MARKERS
Pattern A is the TXDOT Standard, however Pattern B may be used if approved by the Engineer.
lines or at 20 foot spacing for
solid lines. This allows an easier
removal of raised pavement markers
and tape.
Centerline only - not to be used on edge lines
Prefabricated markings may be substituted for reflectorized pavement markings.
Prefabricated markings may be substituted for reflectorized pavement markings.
MARKINGS
PAVEMENT
REFLECTORIZED
MARKINGS
PAVEMENT
REFLECTORIZED
LINE
NO-PASSING
DOUBLE
MARKINGS
PAVEMENT
REFLECTORIZED
MARKERS
PAVEMENT
RAISED
MARKERS
PAVEMENT
RAISED
MARKERS
PAVEMENT
RAISED
MARKERS
PAVEMENT
RAISED
Type II-A-A
3'9'
5'5'
8"
3'9'
Type I-C or II-C-R
MARKERS
PAVEMENT
RAISED
MARKERS
PAVEMENT
RAISEDLINE
LANEDROP
OR
AUXILIARY
LINE
LANE
OR
LINE
CENTER
Item 672 "RAISED PAVEMENT MARKERS."
products list and meet the requirements of
pavement markings shall be from the approved
Raised pavement markers used as standard
TWO-WAY LEFT TURN LANE
LANE & CENTER LINES FOR MULTILANE UNDIVIDED HIGHWAYS
EDGE & LANE LINES FOR DIVIDED HIGHWAY
CENTER LINE & NO-PASSING ZONE BARRIER LINES FOR TWO-LANE, TWO-WAY HIGHWAYS
LINES
SOLID
LINES
BROKEN
Standard
Division
Operations
Traffic
Yellow
White
White
Type Y buttons
Type I-C
Type II-A-A
Type I-C
REFLECTORIZED PAVEMENT MARKINGS RAISED PAVEMENT MARKERS
Prefabricated markings may be substituted for reflectorized pavement markings.
Yellow
White
White Type Y buttonsType II-A-A
Type I-C
Type I-C
REFLECTORIZED PAVEMENT MARKINGS RAISED PAVEMENT MARKERS
Prefabricated markings may be substituted for reflectorized pavement markings.
35
Standard
Division
Operations
Traffic
2-18 36
tcp1-1-18.dgn
TCP(1-1)-18
DN:CK:DW:CK:FILE:
---
-
JOB
COUNTY
SECT
DIST
REVISIONS
-
HIGHWAY
-
SHEET NO.
C TxDOT
of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:CONT
FILE:DATE:$FILE$$DATE$$TIME$
30'Min.BMin.
10'Work SpaceDevices
Channelizing
(See note 2)Work Space30'Min.WORK SPACE ON SHOULDER
48" X 24"
G20-2
ShoulderShoulderShoulder48" X 24"
G20-2
(See note 2)(See note 2)20' spacingDevices at100' Max.150' Min.1/3 LShoulderTCP (1-1b)
48" X 48"
CW20-1D
See note 1)
(Flags-
Devices
Channelizing
(See note 2)
CW20-1D
See note 1)
(Flags-
48" X 48"3X for over 50 mphX for 50 mph or lesstraveled way.
from the nearest
minimum of 30'
work area is a
omitted if the
devices may be
Channelizing 3X for over 50 mphX for 50 mph or less3X for over 50 mphX for 50 mph or less3X for over 50 mphX for 50 mph or less(See notes 4 & 5)
or strobe lights.
oscillating
flashing,
intensity rotating,
with TMA and high
Shadow Vehicle
TCP (1-1a)
WORK SPACE NEAR SHOULDER
Devices
Channelizing
(See note 2)
(See note 2)
Devices
Channelizing
(See note 2)
(See notes 4 & 5)
strobe lights.
oscillating or
flashing,
rotating,
high intensity
with TMA and
Shadow Vehicle
Conventional Roads Conventional Roads
CW20-1D
48" X 48"
See notes 1 & 7)
(Flags-
48" X 48"
CW20-1D
See notes 1 & 7)
(Flags-
GENERAL NOTES
B1/3 LWork SpaceRight-of-way Line(See note 2)20' spacingDevices at100' Max.150' Min.L=Length of Taper(FT) W=Width of Offset(FT) S=Posted Speed(MPH)
Taper lengths have been rounded off.
Conventional Roads Only*
**
TERM STATIONARY
INTERMEDIATE
STATIONARY
LONG TERM
STATIONARY
SHORT TERM
TYPICAL USAGE
MOBILE DURATION
SHORT
Type 3 Barricade
Heavy Work Vehicle
Channelizing Devices
Flag
LEGEND
Flagger
Sign
Message Sign (PCMS)
Portable Changeable
Flashing Arrow Board
Trailer Mounted
M
Traffic Flow
Attenuator (TMA)
Truck Mounted
2
***
75 750'
720'
825'900'75'900'540'
90'
120'
155'
195'
240'
295'
350'
410'
475'
60'
70'
80'
90'
100'
110'
120'
130'
140'
150'
120'
160'
240'
320'
400'
500'
700'
600'
800'
30'
35'
40'
45'
50'
55'
60'
65'
70'
150'
205'
265'
450'
500'
550'
600'
165'
225'
295'
495'
550'
605'
660'
180'
320'
600'
660'
650'715'780'
245'
540'
700'770'840'
30
35
40
45
50
55
60
65
70
60
WSL=
Posted
Speed
"B"
Buffer Space
Longitudinal
Suggested
Tangent
On a
Taper
On a12'
OffsetOffset
11'
Offset
10'
Taper Lengths
Desirable
Minimum
Devices
Channelizing
Spacing of
Suggested Maximum
Formula
L=WS
Spacing
Sign
Minimum
Distance
"X"
48" X 24"
G20-2
(See note 2)
(See Note 3)
vehicle
work
Inactive
roadways.
" signs for shoulder work on conventional "ROAD WORK AHEAD
7. CW21-5 "SHOULDER WORK" signs may be used in place of CW20-1D
freeways.
6. See TCP(5-1)for shoulder work on divided highways, expressways and
surface, next to those shown in order to protect wider work spaces.
5. Additional Shadow Vehicles with TMAs may be positioned off the paved
may be substituted for the Shadow Vehicle and TMA.
to remain in place, Type 3 Barricades or other channelizing devices
longer present but road or work conditions require the traffic control
affecting the performance or quality of the work. If workers are no
30 to 100 feet in advance of the area of crew exposure without adversely
4. A Shadow Vehicle with a TMA should be used anytime it can be positioned
right-of-way line and not parked on the paved shoulder.
3. Inactive work vehicles or other equipment should be parked near the
Engineer.
in the plans, or for routine maintenance work, when approved by the
denoted with the triangle symbol may be omitted when stated elsewhere
2. All traffic control devices illustrated are REQUIRED, except those
1. Flags attached to signs where shown are REQUIRED.
Min.
10'
WORK VEHICLES ON SHOULDERShoulderShoulder48" X 24"
G20-2
(See note 2)
Devices
Channelizing
(See note 2)
TCP (1-1c)Min.30'3X for over 50 mphX for 50 mph or less3X for over 50 mphX for 50 mph or less48" X 48"
CW20-1D
See note 1)
(Flags-
Devices
Channelizing
(See note 2)
devices at all times.
channelization
lanes of traffic by
separated from
remain in areas
cranes, etc., shall
as trucks, moveable
work operation, such
necessary for the
other equipment
Work vehicles or
(See notes 4 & 5)
strobe lights.
oscillating or
rotating, flashing,
high intensity
with TMA and
Shadow Vehicle
Conventional Roads
48" X 48"
CW20-1D
See notes 1 & 7)
(Flags-
SHOULDER WORK
CONVENTIONAL ROAD
TRAFFIC CONTROL PLAN
8-95
2-94
2-12
4-98
1-97
151
December 1985
Standard
Division
Operations
Traffic
2-18 37
tcp1-2-18.dgn
December 1985
TCP(1-2)-18
DN:CK:DW:CK:FILE:
---
-
JOB
COUNTY
SECT
DIST
REVISIONS
-
HIGHWAY
-
SHEET NO.
C TxDOT
of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:CONT
FILE:DATE:$FILE$$DATE$$TIME$X30'Min.50' Min.R1-2aP
48" X 48"Work Space150' Min.BWork SpaceB20' spacingDevices at100' Max.24" X 18"100'200'XXX
CW20-4D
48" X 48"
48" X 48"
CW20-1D
See note 1)
(Flags-
48" X 24"
G20-220' spacingDevices at100' Approx.30'Min..niM '05120' spacingDevices at100" Max.50' Min.
48" X 48"
(See note 2)
(See note 2)
(See note 2)XXX
CW20-4D
48" X 48"
48" X 48"
CW20-1D
See note 1)
(Flags-
48" X 24"
G20-2
TCP (1-2b)
ONE LANE TWO-WAY
X
48" X 36"
42" X 42 " X 42"
Same as Below
in Opposite Direction
Warning Sign Sequence
CW20-4D
48" X 48"
48" X 48"
CW20-1D
See note 1)
(Flags-
48" X 36"
R1-2aP
42" X 42 " X 42"
R1-2
15'XXXTCP (1-2a)
(See note 8)
(See note 8)
ONE LANE TWO-WAY
TCP (1-2a)
TCP (1-2b)
48" X 24"
G20-2
lights.(See notes 5 & 6)
oscillating or strobe
rotating, flashing,
TMA and high intensity
Shadow Vehicle with20' spacingDevices at100' Approx.MOBILE DURATION
SHORT
from traveled way
separate work space
Channelizing devices
CONTROL WITH YIELD SIGNS
(Less than 2000 ADT - See note 7)CONTROL WITH FLAGGERS
at night
illuminated
shall be
flagger stations
emergencies,
Except in
at night
illuminated
shall be
flagger stations
emergencies,
Except in
GENERAL NOTES
Conventional Roads Only*
**
2
***
75 750'825'
150'
205'
265'
450'
500'
550'
600'
165'
225'
295'
495'
550'
605'
660'
650'715'
700'770'
30
35
40
45
50
55
60
65
70
60
WSL=
Posted
Speed
Offset
11'
Offset
10'
Formula
L=WS
(See notes 5 & 6)
or strobe lights.
oscillating
flashing,
intensity rotating,
with TMA and high
Shadow Vehicle
R1-2 48" X 48"
CW3-4
(See note 2)
CW20-7
48" X 48"
CW16-2P
CW20-7
48" X 48"
24" X 18"
CW16-2P
CW3-4
CW3-2
TERM STATIONARY
INTERMEDIATE
STATIONARY
LONG TERM
STATIONARY
SHORT TERM
Type 3 Barricade
Heavy Work Vehicle
Channelizing Devices
Flag
LEGEND
Flagger
Sign
Message Sign (PCMS)
Portable Changeable
Flashing Arrow Board
Trailer Mounted
M
Traffic Flow
Attenuator (TMA)
Truck Mounted
TYPICAL USAGE
L=Length of Taper(FT) W=Width of Offset(FT) S=Posted Speed(MPH)
Taper lengths have been rounded off.
720'
900'75'900'540'
90'
120'
155'
195'
240'
295'
350'
410'
475'
60'
70'
80'
90'
100'
110'
120'
130'
140'
150'
120'
160'
240'
320'
400'
500'
700'
600'
800'
30'
35'
40'
45'
50'
55'
60'
65'
70'
180'
320'
600'
660'
780'
245'
540'
840'
"B"
Buffer Space
Longitudinal
Suggested
Tangent
On a
Taper
On a12'
Offset
Taper Lengths
Desirable
Minimum
Devices
Channelizing
Spacing of
Suggested Maximum
Spacing
Sign
Minimum
Distance
"X"Distance
Sight
Stopping
200'
250'
305'
360'
425'
495'
570'
645'
730'
820'
limited to emergency situations.
13. Flaggers should use 24" STOP/SLOW paddles to control traffic. Flags should be
traffic and approved by the Engineer.
12. Channelizing devices on the center-line may be omitted when a pilot car is leading
and a queue of stopped vehicles (see table above).
should be increased in order to maintain adequate stopping sight distance to the flagger
11. If the work space is located near a horizontal or vertical curve, the buffer distances
10. Length of work space should be based on the ability of flaggers to communicate.
9. Flaggers should use two-way radios or other methods of communication to control traffic.
at a 7 foot minimum mounting height.
8. R1-2 "YIELD" sign with R1-2aP "TO ONCOMING TRAFFIC" plaque shall be placed on a support
spaces should be no longer than 400 feet.
than one half city block. In rural areas on roadways with less than 2000 ADT, work
adequate sight distance. For projects in urban areas, work spaces should be no longer
7. R1-2 "YIELD" sign traffic control may be used on projects with approaches that have
those shown in order to protect wider work spaces.
6. Additional Shadow Vehicles with TMAs may be positioned off the paved surface, next to
may be substituted for the Shadow Vehicle and TMA.
the traffic control to remain in place, Type 3 Barricades or other channelizing devices
quality of the work. If workers are no longer present but road or work conditions require
in advance of the area of crew exposure without adversely affecting the performance or
5. A Shadow Vehicle with a TMA should be used anytime it can be positioned 30 to 100 feet
used if advance warning ahead of the flagger or R1-2 "YIELD" sign is less than 1500 feet.
4. Sign spacing may be increased or an additional CW20-1D "ROAD WORK AHEAD" sign may be
ROAD AHEAD" sign, but proper sign spacing shall be maintained.
3. The CW3-4 "BE PREPARED TO STOP" sign may be installed after the CW20-4D "ONE LANE
maintenance work, when approved by the Engineer.
triangle symbol may be omitted when stated elsewhere in the plans, or for routine
2. All traffic control devices illustrated are REQUIRED, except those denoted with the
1. Flags attached to signs where shown are REQUIRED.
TRAFFIC CONTROL
ONE-LANE TWO-WAY
TRAFFIC CONTROL PLAN
2-12
4-90
2-94
1-97
4-98
152
Standard
Division
Operations
Traffic
2-18
38
tcp1-3-18.dgn
TCP(1-3)-18
DN:CK:DW:CK:FILE:
---
-
JOB
COUNTY
SECT
DIST
REVISIONS
-
HIGHWAY
-
SHEET NO.
C TxDOT
of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:CONT FILE:DATE:$FILE$$DATE$$TIME$XShoulderShoulderShoulder30'2XX/2CW1-4R
Work SpaceBBBBWork SpaceBMin.30'48" X 48"
48" X 48"
CW20-1D
See note 1)
(Flags-
GENERAL NOTES
48" X 24"
G20-2 ShoulderX/2Min. 2XX
TCP (1-3a)TCP (1-3b)
2-LANE ROADWAY WITH PAVED SHOULDERS
ADEQUATE FIELD OF VIEW
ONE LANE CLOSED
2-LANE ROADWAY WITH PAVED SHOULDERS
INADEQUATE FIELD OF VIEW
ONE LANE CLOSED100' Approx.48" X 24"
G20-2
48" X 48"
CW1-4R
Xas needed
Flagger
(See note 3)
48" X 48"
CW20-1D
See note 1)
(Flags-2XX 50'-100'100'Approx.Min.30'lane (See note 5)
placed across closed
Channelizing devices
Xlights.(See notes 6 & 7)
oscillating or strobe
rotating, flashing,
TMA and high intensity
Shadow Vehicle with
as needed
Flagger
(See note 3)
See note 1)
(Flags-
CW20-1D
48" X 48"
lights. (See notes 6 & 7)
oscillating or strobe
rotating, flashing,
TMA and high intensity
Shadow Vehicle with
lights.(See notes 2 & 6)
oscillating or strobe
rotating, flashing,
TMA and high intensity
Shadow Vehicle with
1/2 L1/2 L1/2 L1/2 L1/2 L1/2 L1/2 L1/2 L(See note 2)
24" X 24"
CW13-1P
CW1-6aT
36" X 36"
(See note 2)
24" X 24"
CW13-1P
(See note 2)
24" X 24"
CW13-1P
CW1-6aT
36" X 36"
(See note 2)
CW20-7
48" X 48"
CW1-6aT
36" X 36"
CW1-6aT
36" X 36"
(See note 2)
(See note 2)
24" X 24"
CW13-1P
48" X 48"
CW1-4R
48" X 24"
G20-2
CW1-4L
48" X 48"
(See note 2)
24" X 24"
CW13-1P
CW1-6aT
36" X 36"
(See note 2)
G20-2
48" X 24"
(See note 2)
24" X 24"
CW13-1P
48" X 48"
CW1-4L
48" X 48"
CW3-4
CONTROL TRAFFIC
USE ONLY WHEN FLAGGERS
48" X 48"
CW1-4L
CW1-4L
48" X 48"
CW13-1P
(See note 2)
24" X 24"
CW20-1D
48" X 48"
See note 1)
(Flags-
CW1-6aT
36" X 36"
(See note 2)ecapS kroW(See Notes 2 & 3)
For either TCP(1-3a) or TCP(1-3b)
TERM STATIONARY
INTERMEDIATE
STATIONARY
LONG TERM
STATIONARY
SHORT TERM
TYPICAL USAGE
MOBILE DURATION
SHORT
Type 3 Barricade
Heavy Work Vehicle
Channelizing Devices
Flag
LEGEND
Flagger
Sign
Message Sign (PCMS)
Portable Changeable
Flashing Arrow Board
Trailer Mounted
M
Traffic Flow
Attenuator (TMA)
Truck Mounted
L=Length of Taper(FT) W=Width of Offset(FT) S=Posted Speed(MPH)
Taper lengths have been rounded off.
Conventional Roads Only*
**
2
*
**
75 750'
720'
825'900'75'900'540'
90'
120'
155'
195'
240'
295'
350'
410'
475'
60'
70'
80'
90'
100'
110'
120'
130'
140'
150'
120'
160'
240'
320'
400'
500'
700'
600'
800'
30'
35'
40'
45'
50'
55'
60'
65'
70'
150'
205'
265'
450'
500'
550'
600'
165'
225'
295'
495'
550'
605'
660'
180'
320'
600'
660'
650'715'780'
245'
540'
700'770'840'
30
35
40
45
50
55
60
65
70
60
WSL=
Posted
Speed
"B"
Buffer Space
Longitudinal
Suggested
Tangent
On a
Taper
On a12'
OffsetOffset
11'
Offset
10'
Taper Lengths
Desirable
Minimum
Devices
Channelizing
Spacing of
Suggested Maximum
Formula
L=WS
Spacing
Sign
Minimum
Distance
"X"
area of conflicting markings not the entire work zone.
where S is the speed in mph. This tighter device spacing is intended for the
if posted speed are 35 mph or slower, and for tangent sections, at 1/2S
which separate two-way traffic should be spaced on tapers at 20', or 15'
8. Where traffic is directed over a yellow centerline, channelizing devices
surface, next to those shown in order to protect wider work spaces.
7. Additional Shadow Vehicles with TMAs may be positioned off the paved
devices may be substituted for the Shadow Vehicle and TMA.
traffic control to remain in place, Type 3 Barricades or other channelizing
workers are no longer present but road or work conditions require the
adversely affecting the performance or quality of the work. If
30 to 100 feet in advance of the area of crew exposure without
6. A Shadow Vehicle with a TMA should be used anytime it can be positioned
feet in urban areas and every 1/4 to 1/2 mile in rural areas.
Laterally placed channelizing devices should be repeated every 500 to 1000
should be placed laterally across the closed lane to re-emphasize closure.
5. When the work zone is made up of several work spaces, channelizing devices
zone signs may be installed downstream of the ROAD WORK AHEAD signs.
4. DO NOT PASS, PASS WITH CARE and construction regulatory speed
alert traffic to reduce speed.
Additional flaggers may be positioned in advance of traffic queues to
traffic volume require additional emphasis to safely control traffic.
3. Flagger control should NOT be used unless roadway conditions or heavy
or for routine maintenance work, when approved by the Engineer.
with the triangle symbol may be omitted when stated elsewhere in the plans,
2. All traffic control devices illustrated are REQUIRED, except those denoted
1. Flags attached to signs where shown are REQUIRED.
TWO LANE ROADS
TRAFFIC SHIFTS ON
TRAFFIC CONTROL PLAN
December 1985
8-95
2-94
2-12
1-97
4-98
153
Standard
Division
Operations
Traffic
2-18
TCP(1-4)-18
39
tcp1-4-18.dgn DN:CK:DW:CK:FILE:
---
-
JOB
COUNTY
SECT
DIST
REVISIONS
-
HIGHWAY
-
SHEET NO.
C TxDOT
of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:CONT FILE:DATE:$FILE$$DATE$$TIME$TCP (1-4b)Work SpaceBWork SpaceBBLXXXXXX1/3 LLMin.30'ShoulderCW20-5TL
48" X 48"Min.30'XXX1/3 LLCW20-1D
See note 1)
(Flags-
48" X 48"
lights.(See notes 4 & 5)
oscillating or strobe
rotating, flashing,
TMA and high intensity
Shadow Vehicle with
48" X 24"
G20-2
48" X 24"
G20-2
Approx.100' TWO LANES CLOSED
CW20-1D
48" X 48"
See note 1)
(Flags-
CW20-5TR
48" X 48"
CW1-4L
48" X 48"
(See note 2)
24" X 24"
CW1-4R
48" X 48"
CW20-1D
48" X 48"
See note 1)
(Flags-ShoulderShoulderShoulderCW20-1D
48" X 48"
See note 1)
(Flags-LShoulder(See note 7)
lights.(See notes 4 & 5)
oscillating or strobe
rotating, flashing,
TMA and high intensity
Shadow Vehicle with
48" X 24"
G20-2 Shoulder200'Approx.XX
48" X 24"
G20-2
CW20-5TR
48" X 48"1Min./2 L1Min./2 Lx for 50 mph or less3x for over 50 mphONE LANE CLOSED
CW1-6aT
36" X 36"
CW13-1P
TCP (1-4a)
Type 3 Barricade
Heavy Work Vehicle
Channelizing Devices
Flag
LEGEND
Flagger
Sign
Message Sign (PCMS)
Portable Changeable
Flashing Arrow Board
Trailer Mounted
M
Traffic Flow
Attenuator (TMA)
Truck Mounted
L=Length of Taper(FT) W=Width of Offset(FT) S=Posted Speed(MPH)
Taper lengths have been rounded off.
Conventional Roads Only*
**
2
***
75 750'
720'
825'900'75'900'540'
90'
120'
155'
195'
240'
295'
350'
410'
475'
60'
70'
80'
90'
100'
110'
120'
130'
140'
150'
120'
160'
240'
320'
400'
500'
700'
600'
800'
30'
35'
40'
45'
50'
55'
60'
65'
70'
150'
205'
265'
450'
500'
550'
600'
165'
225'
295'
495'
550'
605'
660'
180'
320'
600'
660'
650'715'780'
245'
540'
700'770'840'
30
35
40
45
50
55
60
65
70
60
WS
L=
Posted
Speed
"B"
Buffer Space
Longitudinal
Suggested
Tangent
On a
Taper
On a12'
OffsetOffset
11'
Offset
10'
Taper Lengths
Desirable
Minimum
Devices
Channelizing
Spacing of
Suggested Maximum
Formula
L=WS
Spacing
Sign
Minimum
Distance
"X"
TERM STATIONARY
INTERMEDIATE
STATIONARY
LONG TERM
STATIONARY
SHORT TERM
TYPICAL USAGE
MOBILE DURATION
SHORT
GENERAL NOTES
TCP (1-4a)
TCP (1-4b)
for the areas of conflicting markings, not the entire work zone.
where S is the speed in mph. This tighter device spacing is intended
if posted speeds are 35 mph or slower, and for tangent sections, at 1/2S
which separate two-way traffic should be spaced on tapers at 20' or 15'
7. Where traffic is directed over a yellow centerline, channelizing devices
the arrow panel placed in the closed lane near the end of the merging taper.
centerline where needed to protect the work space from opposing traffic with
signs shall be used and channelizing devices shall be placed on the
6. If this TCP is used for a left lane closure , CW20-5TL "LEFT LANE CLOSED"
surface, next to those shown in order to protect wider work spaces.
5. Additional Shadow Vehicles with TMAs may be positioned off the paved
for the Shadow Vehicle and TMA.
place, Type 3 Barricades or other channelizing devices may be substituted
present but road or work conditions require the traffic control to remain in
affecting the performance or quality of the work. If workers are no longer
30 to 100 feet in advance of the area of crew exposure without adversely
4. A Shadow Vehicle with a TMA should be used anytime it can be positioned
visibility of the work zone is less than 1500 feet.
3. The CW20-1D "ROAD WORK AHEAD" sign may be repeated if the
or for routine maintenance work, when approved by the Engineer.
with the triangle symbol may be omitted when stated elsewhere in the plans,
2. All traffic control devices illustrated are REQUIRED, except those denoted
1. Flags attached to signs where shown are REQUIRED.
(See note 2)
24" X 24"
CW13-1P
CW1-6aT
36" X 36"
(See note 2)
CONVENTIONAL ROADS
LANE CLOSURES ON MULTILANE
TRAFFIC CONTROL PLAN
CONVENTIONAL ROADS
LANE CLOSURES ON MULTILANE
TRAFFIC CONTROL PLAN
2-94
8-95
1-97
4-98
2-12
154
December 1985
Standard
Division
Operations
Traffic
tcp1-5-18.dgn
2-18
TCP(1-5)-18
40
DN:CK:DW:CK:FILE:
---
-
JOB
COUNTY
SECT
DIST
REVISIONS
-
HIGHWAY
-
SHEET NO.
C TxDOT
of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:CONT
FILE:DATE:$FILE$$DATE$$TIME$MedianShoulderShoulderMedianShoulderWork SpaceWork SpaceBL500' Min.TCP (1-5b)TCP (1-5c)
LANE CLOSURE NEAR ENTRANCE RAMPS
48" X 24"
G20-2
closure
for lane
devices
control
for traffic
See TCP(1-5a) 500'FRONTAGE RD.1/3 LLMin.30'48" X 48"
CW20RP-3D500' min.
48" X 24"
G20-2
ShoulderLANE CLOSURE NEAR EXIT RAMPS1/3 LMin.30' L100' Min.1000'48" X 36"
E5-2
1
0' Mi
n.Work SpaceBTCP (1-5a)2600'1000'1600'1/3 LL500' Min. MedianShoulderShoulderCW20-5TR
48" X 48"
CW20-5TR
48" X 48"Shoulder30' Min.ONE LANE CLOSURE
to enter the ramp.
is normally required
to close a lane which
lane closure is needed
closure details if a
See TCP(1-4a) for lane
4 & 5)
(See notes
G20-2
48" X 24"
(See notes 4 & 5)
(See notes 4 & 5)
48" X 30"
R11-2bT
CW20-1F
48" X 48"
See note 1)
(Flags-
48" X 42"
E5-1
for lane closure
warning signs
for advance
See TCP(1-5a)
for lane closure
warning signs
for advance
See TCP(1-5a)
GENERAL NOTES
TERM STATIONARY
INTERMEDIATE
STATIONARY
LONG TERM
STATIONARY
SHORT TERM
TYPICAL USAGE
MOBILE DURATION
SHORT
Type 3 Barricade
Heavy Work Vehicle
Channelizing Devices
Flag
LEGEND
Flagger
Sign
Message Sign (PCMS)
Portable Changeable
Flashing Arrow Board
Trailer Mounted
M
Traffic Flow
Attenuator (TMA)
Truck Mounted
L=Length of Taper(FT) W=Width of Offset(FT) S=Posted Speed(MPH)
Taper lengths have been rounded off.
Conventional Roads Only*
**
2
***
75 750'
720'
825'900'75'900'540'
90'
120'
155'
195'
240'
295'
350'
410'
475'
60'
70'
80'
90'
100'
110'
120'
130'
140'
150'
120'
160'
240'
320'
400'
500'
700'
600'
800'
30'
35'
40'
45'
50'
55'
60'
65'
70'
150'
205'
265'
450'
500'
550'
600'
165'
225'
295'
495'
550'
605'
660'
180'
320'
600'
660'
650'715'780'
245'
540'
700'770'840'
30
35
40
45
50
55
60
65
70
60
WS
L=
Posted
Speed
"B"
Buffer Space
Longitudinal
Suggested
Tangent
On a
Taper
On a12'
OffsetOffset
11'
Offset
10'
Taper Lengths
Desirable
Minimum
Devices
Channelizing
Spacing of
Suggested Maximum
Formula
L=WS
Spacing
Sign
Minimum
Distance
"X"
shown in order to protect a wider work space.
closed lane, on the shoulder or off the paved surface, next to those
5. Additional Shadow Vehicles with TMAs may be positioned in each
Shadow Vehicle and TMA.
Barricades or other channelizing devices may be substituted for the
work conditions require the traffic control to remain in place, Type 3
quality of the work. If workers are no longer present but road or
of crew exposure without adversely affecting the performance or
used anytime it can be positioned 30 to 100 feet in advance of the area
oscillating or strobe lights. A Shadow Vehicle with a TMA should be
4. Shadow Vehicle with TMA and high intensity rotating, flashing,
device. Chevrons may be attached to plastic drums as per BC Standards.
with the Chevron Alignment Sign placed on every other channelizing
3. Channelizing devices used to close lanes may be supplemented
Engineer.
in the plans, or for routine maintenance work, when approved by the
denoted with the triangle symbol may be omitted when stated elsewhere
2. All traffic control devices illustrated are REQUIRED, except those
1. Flags attached to signs where shown, are REQUIRED.
48" X 48"
CW25-1T
20' spacing
Devices at
Channelizing
DIVIDED HIGHWAYS
LANE CLOSURES FOR
TRAFFIC CONTROL PLAN
February 2012
155
Standard
Division
Operations
Traffic
TCP(1-6)-18
41
tcp1-6-18.dgn
2-18
DN:CK:DW:CK:FILE:
---
-
JOB
COUNTY
SECT
DIST
REVISIONS
-
HIGHWAY
-
SHEET NO.
C TxDOT
of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:CONT
FILE:DATE:$FILE$$DATE$$TIME$XWork SpaceBXX
CW20-4D
48" X 48"
48" X 48"
CW20-1D
See note 1)
(Flags-
48" X 24"
G20-220' spacingDevices at100' Approx.30'Min..niM '05120' spacingDevices at100' Max.50' Min.
48" X 48"XX
CW20-4D
48" X 48"
48" X 48"
CW20-1D
See note 1)
(Flags-
48" X 24"
G20-2
TCP (1-6b)
ONE LANE TWO-WAY
X
(See notes 7 & 8)
or strobe lights.
oscillating
flashing,
intensity rotating,
with TMA and high
Shadow Vehicle
CW3-4
ONE LANE TWO-WAY CONTROL
WITH RED/YELLOW LENS AFADs
10' spacing
6 CDs at
STOP
HERE ON
RED 100' to 200'20'
(See note 15)
24" X 36"
R10-6
spacing
6 CDs at 10'
STOP
HERE ON
RED
(See note 15)
24" X 36"
R10-6
20'B48" X 48"
CW20-1D
See note 1)
(Flags-
48" X 24"
G20-220' spacingDevices at100' Approx.30'Min.
48" X 24"
G20-2
(See notes 7 & 8)
or strobe lights.
oscillating
flashing,
intensity rotating,
with TMA and high
Shadow Vehicle
10' spacing
6 CDs at
100' to 200'
spacing
6 CDs at 10'
(See note 14)
24" X 30"
R1-7aT
24" X 30"
R1-8aT
(See note 14)
24" X 30"
R1-7aT
TCP (1-6a)
CW20-4D
48" X 48"
XX
X
20' spacingDevices at100' Max.50' Min.XXXWork Space48" X 48"
CW3-4
CW20-4D
48" X 48"
48" X 48"
CW20-1D
See note 1)
(Flags-
.niM '05148" X 48"
CW3-4
48" X 48"
CW3-4
SLOW
SLOW
24" X 30"
R1-8aT
CONTROL WITH STOP/SLOW AFADs
TERM STATIONARY
INTERMEDIATE
STATIONARY
LONG TERM
STATIONARY
SHORT TERMMOBILEDURATION
SHORT
GENERAL NOTES
TYPICAL USAGE
L=Length of Taper(FT) W=Width of Offset(FT) S=Posted Speed(MPH)
Taper lengths have been rounded off.
Conventional Roads Only*
**
2
***
75 750'
720'
825'900'75'900'540'
90'
120'
155'
195'
240'
295'
350'
410'
475'
60'
70'
80'
90'
100'
110'
120'
130'
140'
150'
120'
160'
240'
320'
400'
500'
700'
600'
800'
30'
35'
40'
45'
50'
55'
60'
65'
70'
150'
205'
265'
450'
500'
550'
600'
165'
225'
295'
495'
550'
605'
660'
180'
320'
600'
660'
650'715'780'
245'
540'
700'770'840'
30
35
40
45
50
55
60
65
70
60
WS
L=
Posted
Speed
"B"
Buffer Space
Longitudinal
Suggested
Tangent
On a
Taper
On a12'
OffsetOffset
11'
Offset
10'
Taper Lengths
Desirable
Minimum
Devices
Channelizing
Spacing of
Suggested Maximum
Formula
L=WS
Spacing
Sign
Minimum
Distance
"X"
Type 3 Barricade
Heavy Work Vehicle
Channelizing Devices (CDs)
Flag
LEGEND
Flagger
Sign
Message Sign (PCMS)
Portable Changeable
M
Traffic Flow
Attenuator (TMA)
Truck Mounted
(AFAD)
Assistance Device
Automated Flagger
Distance
Sight
Stopping
200'
250'
305'
360'
425'
495'
570'
645'
730'
820'
the lenses of the AFAD.
15. The R10-6 "STOP HERE ON RED" arrow sign shall be offset so as not to obscure
one 48" x 30" sign. They shall not obscure the face of the STOP/SLOW AFAD.
be installed at the AFAD location on separate supports or they may be fabricated as
14. The R1-7aT "WAIT ON STOP" sign and the R1-8aT "GO ON SLOW" sign shall
traffic and approved by the Engineer.
13. Channelizing devices on the center line may be omitted when a pilot car is leading
should be increased in order to maintain stopping sight distance to the AFAD.
12. If the work space is located near a horizontal or vertical curve, the buffer distances
11. Length of work space should be based on the ability of flaggers to communicate.
10. Flaggers should use two-way radios or other methods of communication to control traffic.
those shown in order to protect wider work spaces.
9. Additional Shadow Vehicles with TMAs may be positioned off the paved surface, next to
other channelizing devices may be substituted for the Shadow Vehicle and TMA.
work conditions require the traffic control to remain in place, Type 3 Barricades or
the performance or quality of the work. If workers are no longer present but road or
100 feet in advance of the area of crew exposure without adversely affecting
8. A Shadow Vehicle with a TMA should be used anytime it can be positioned 30 to
flag attached to the end of the gate arm. The flag shall be a minimum of 16" square.
7. All AFADs shall be equipped with gate arms with an orange or fluorescent red-orange
approach. AFADs shall not be operated by the pilot car operator.
6. When pilot cars are used, a flagger controlling traffic shall be located on each
both AFADs and of the approaching traffic in both directions.
5. One flagger may operate two AFADs only when the flagger has an unobstructed view of
shall not leave them unattended while they are in use.
4. Each AFAD shall be operated by a qualified/certified flagger. Flaggers operating AFADs
traffic. (See table above).
3. Adequate stopping sight distance must be provided to each AFAD location for approaching
in the direction to be controlled.
2. AFADs shall only be used in situations where there is one lane of approaching traffic
1. Flags attached to signs where shown are REQUIRED.
TRAFFIC CONTROL PLAN
(AFADS)
ASSISTANCE DEVICES
AUTOMATED FLAGGER
156
February 2012
Standard
Division
Operations
TrafficApprox.100'Min.30'Work Space100'Min.30' 1/3 LB 1/3 LBWork SpaceMin.30'Min.
10'100'Approx.100'Min.30'Min.30'Min.30'Min.
10'x for 50 mph or less3x for over 50 mphor lessx for 50 mph 50 mph3x for over 50 mph3x for over or lessx for 50 mph or lessx for 50 mph or lessx for 50 mph or lessx for 50 mph 50 mph3x for over 50 mph3x for over 50 mph3x for over TCP(2-1)-18
2-18
DN:tcp2-1-18.dgn
42
CK:DW:CK:FILE:
---
-
JOB
COUNTY
SECT
DIST
REVISIONS
-
HIGHWAY
-
SHEET NO.
C TxDOT
of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:CONT FILE:DATE:$FILE$$DATE$$TIME$Work SpaceShoulderShoulderShoulderTCP (2-1b)TCP (2-1c)
WORK SPACE ON SHOULDER WORK VEHICLES ON SHOULDER
See note 1)
48" X 48"
(Flags-
CW20-1D
CW20-1D
48" X 48"
See note 1)
(Flags-
(See note 2)
G20-2
48" X 24"ShoulderShoulder See note 1)
48" X 48"
(Flags-
CW20-1D
48" X 24"
(See note 2)
G20-2
See note 1)
48" X 48"
(Flags-
CW20-1D
(See note 2)
G20-2
48" X 24"
48" X 24"
(See note 2)
G20-2
Right-of-way LineShoulderShoulderShoulderShoulderShoulderShoulderShoulder See note 1)
48" X 48"
(Flags-
CW20-1D
(See notes 4 & 5)
(See notes 4 & 5)
CW20-1D
48" X 48"
See note 1)
(Flags-
nearest traveled way.
of 30' from the
work area is a minimum
may be omitted if the
Channelizing devices
at all times.
channelizing devices
lanes of traffic by
areas separated from
etc., shall remain in
moveable cranes,
such as trucks,
work operation,
necessary for the
or other equipment
Work vehicles
TCP (2-1a)
WORK SPACE NEAR SHOULDER
Conventional Roads Conventional Roads Conventional Roads
(See Note 7)
work vehicle
Inactive
(See notes 4 & 5)
Type 3 Barricade
Heavy Work Vehicle
Channelizing Devices
Flag
LEGEND
Flagger
Sign
Message Sign (PCMS)
Portable Changeable
Flashing Arrow Board
Trailer Mounted
M
Traffic Flow
Attenuator (TMA)
Truck Mounted
L=Length of Taper(FT) W=Width of Offset(FT) S=Posted Speed(MPH)
Taper lengths have been rounded off.
Conventional Roads Only*
**
2
***
75 750'
720'
825'900'75'900'540'
90'
120'
155'
195'
240'
295'
350'
410'
475'
60'
70'
80'
90'
100'
110'
120'
130'
140'
150'
120'
160'
240'
320'
400'
500'
700'
600'
800'
30'
35'
40'
45'
50'
55'
60'
65'
70'
150'
205'
265'
450'
500'
550'
600'
165'
225'
295'
495'
550'
605'
660'
180'
320'
600'
660'
650'715'780'
245'
540'
700'770'840'
30
35
40
45
50
55
60
65
70
60
WSL=
Posted
Speed
"B"
Buffer Space
Longitudinal
Suggested
Tangent
On a
Taper
On a12'
OffsetOffset
11'
Offset
10'
Taper Lengths
Desirable
Minimum
Devices
Channelizing
Spacing of
Suggested Maximum
Formula
L=WS
Spacing
Sign
Minimum
Distance
"X"
TERM STATIONARY
INTERMEDIATE
STATIONARY
LONG TERM
STATIONARY
SHORT TERM
TYPICAL USAGE
MOBILE DURATION
SHORT
GENERAL NOTES
"ROAD WORK AHEAD" signs for shoulder work on conventional roadways.
8. CW21-5 "SHOULDER WORK" signs may be used in place of CW21-1D
right-of-way line and not parked on the paved shoulder.
7. Inactive work vehicles or other equipment should be parked near the
freeways.
6. See TCP(5-1) for shoulder work on divided highways, expressways and
surface, next to those shown in order to protect a wider work space.
5. Additional Shadow Vehicles with TMAs may be positioned off the paved
substituted for the Shadow Vehicle and TMA.
place, Type 3 Barricades or other channelizing devices may be
but road or work conditions require the traffic control to remain in
performance or quality of the work. If workers are no longer present
the area of crew exposure without adversely affecting the
used anytime it can be positioned 30 to 100 feet in advance of
oscillating or strobe lights. A Shadow Vehicle with a TMA should be
4. Shadow Vehicle with TMA and high intensity rotating, flashing,
nearest traveled way.
3. Stockpiled material should be placed a minimum of 30 feet from
plans, or for routine maintenance work, when approved by the Engineer.
denoted with the triangle symbol may be omitted when stated in the
2. All traffic control devices illustrated are REQUIRED, except those
1. Flags attached to signs where shown, are REQUIRED.
SHOULDER WORK
CONVENTIONAL ROAD
TRAFFIC CONTROL PLAN
2-94
8-95
1-97
4-98
161
2-12
December 1985
Standard
Division
Operations
Traffic100'2-18
tcp2-2-18.dgn
TCP(2-2)-18
43
DN:CK:DW:CK:FILE:
---
-
JOB
COUNTY
SECT
DIST
REVISIONS
-
HIGHWAY
-
SHEET NO.
C TxDOT
of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:CONT
FILE:DATE:$FILE$$DATE$$TIME$XXXWork SpaceBMin.30'Min.100'TCP (2-2a)
2-LANE ROADWAY WITHOUT PAVED SHOULDERS
48" X 24"
G20-2
(See Note 2)
Yield Line
Temporary
Approx.100'100' Max.50' Min.48" X 48"
CW20-4D
48" X 48"
48" X 48"
CW20-1D
See note 1)
(Flags-
42" X 42 " X 42"
R1-2
48" X 24"
G20-2 15'(See Note 2)
Yield Line
Temporary
W3-2
R1-2
42" X 42 " X 42"
Same as Below
in Opposite Direction
Warning Sign Sequence
lights.(See notes 6 & 7)
oscillating or strobe
rotating, flashing,
TMA and high intensity
Shadow Vehicle with
CONTROL WITH YIELD SIGNS
ONE LANE TWO-WAY
(Less than 2000 ADT - See Note 9)200'Min.30'BWork SpaceXXX
50'Min.100' Max.Temporary
(See Note 2)Min.100'
48" X 24"
G20-2
CW20-4
48" X 48"
48" X 24"
G20-2
48" X 48"
CW20-1D
See note 1)
(Flags-
CW20-4
48" X 48"
24" X 18"XXXX
48" X 48"
(See note 2)
X
24" Stop Line
at night
illuminated
shall be
flagger stations
emergencies,
Except in
at night
illuminated
shall be
flagger stations
emergencies,
Except in
Temporary
(See Note 2)
24" Stop Line
2-LANE ROADWAY WITHOUT PAVED SHOULDERS
ONE LANE TWO-WAY
CONTROL WITH FLAGGERS
TCP (2-2b)
(See notes 6 & 7)
strobe lights.
oscillating or
flashing,
rotating,
high intensity
with TMA and
Shadow Vehicle
24" X 18"
CW16-2P
CW20-7
48" X 48"
CW20-7
48" X 48"
CW16-2P
CW3-4
48" X 48"
(See note 2)
CW3-4
R1-2aP
48" X 36"
(See note 9)
48" X 36"
R1-2aP
(See note 9)
20' spacing
Devices at
100' Approx.
spacing on the Taper
Devices at 20'
spacing on the Taper
Devices at 20'
on the Taper
20' spacing
Devices at
GENERAL NOTES
TCP (2-2b)
TCP (2-2a)
TERM STATIONARY
INTERMEDIATE
STATIONARY
LONG TERM
STATIONARY
SHORT TERM
TYPICAL USAGE
MOBILE DURATION
SHORT
Type 3 Barricade
Heavy Work Vehicle
Channelizing Devices
Flag
LEGEND
Flagger
Sign
Message Sign (PCMS)
Portable Changeable
Flashing Arrow Board
Trailer Mounted
M
Traffic Flow
Attenuator (TMA)
Truck Mounted
L=Length of Taper(FT) W=Width of Offset(FT) S=Posted Speed(MPH)
Taper lengths have been rounded off.
Conventional Roads Only*
**
2
***
75 750'
720'
825'900'75'900'540'
90'
120'
155'
195'
240'
295'
350'
410'
475'
60'
70'
80'
90'
100'
110'
120'
130'
140'
150'
120'
160'
240'
320'
400'
500'
700'
600'
800'
30'
35'
40'
45'
50'
55'
60'
65'
70'
150'
205'
265'
450'
500'
550'
600'
165'
225'
295'
495'
550'
605'
660'
180'
320'
600'
660'
650'715'780'
245'
540'
700'770'840'
30
35
40
45
50
55
60
65
70
60
WSL=
Posted
Speed
"B"
Buffer Space
Longitudinal
Suggested
Tangent
On a
Taper
On a12'
OffsetOffset
11'
Offset
10'
Taper Lengths
Desirable
Minimum
Devices
Channelizing
Spacing of
Suggested Maximum
Formula
L=WS
Spacing
Sign
Minimum
Distance
"X"
48" X 48"
CW20-1D
See note 1)
(Flags-
Distance
Sight
Stopping
200'
250'
305'
360'
425'
495'
570'
645'
730'
820'
mounting height.
9. The R1-2aP "YIELD TO ONCOMING TRAFFIC" sign shall be placed on a support at a 7 foot minimum
In rural areas, roadways with less than 2000 ADT, work space should be no longer than 400 feet.
distance. For projects in urban areas, work space should be no longer than one half city block.
8. The R1-2 "YIELD" sign traffic control may be used on projects with approaches that have adequate sight
in order to protect a wider work space.
7. Additional Shadow Vehicles with TMAs may be positioned off the paved surface, next to those shown
Vehicle and TMA.
to remain in place, Type 3 Barricades or other channelizing devices may be substituted for the Shadow
the work. If workers are no longer present but road or work conditions require the traffic control
in advance of the area of crew exposure without adversely affecting the performance or quality of
6. A Shadow Vehicle with a TMA should be used anytime it can be positioned 30 to 100 feet
5. Length of work space should be based on the ability of flaggers to communicate.
4. Flaggers should use two-way radios or other methods of communication to control traffic.
ROAD XXX FT" sign, but proper sign spacing shall be maintained.
3. The CW3-4 "BE PREPARED TO STOP" sign may be installed after the CW20-4 "ONE LANE
by the Engineer.
may be omitted when stated elsewhere in the plans, or for routine maintenance work, when approved
2. All traffic control devices illustrated are REQUIRED, except those denoted with the triangle symbol
1. Flags attached to signs where shown, are REQUIRED.
emergency situtations.
12.Flaggers should use 24" STOP/SLOW paddles to control traffic. Flags should be limited to
(See table above).
increased in order to maintain stopping sight distance to the flagger and a queue of stopped vehicles.
11.If the work space is located near a horizontal or vertical curve, the buffer distances should be
approved by the Engineer.
10.Channelizing devices on the center line may be omitted when a pilot car is leading traffic and
TRAFFIC CONTROL
ONE-LANE TWO-WAY
TRAFFIC CONTROL PLAN
8-95
1-97
4-98
3-03
2-12
162
December 1985
Standard
Division
Operations
Traffic
TCP(2-3)-18
44
tcp(2-3)-18.dgn
2-18
DN:CK:DW:CK:FILE:
---
-
JOB
COUNTY
SECT
DIST
REVISIONS
-
HIGHWAY
-
SHEET NO.
C TxDOT
of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:CONT
FILE:DATE:$FILE$$DATE$$TIME$Paved ShoulderPaved Shoulder 1/2 L 1/2 L 1/2 L 1/2 LBWork SpaceB 1/2 LWork SpaceWork Space 1/2 LBBTCP (2-3a)TCP (2-3b)XXXX48" X 24"
G20-2
24" X 30"
R4-2
24" X 30"
R4-1
48" X 48"
CW20-1D
See note 1)
(Flags-
lights. (See notes 7 & 8)
oscillating or strobe
rotating, flashing,
TMA and high intensity
Shadow Vehicle with
CW1-4R
48" X 48"XXXXMin.30'100' Approx.24" X 30"
R4-1
See note 1)
(Flags-
48" X 48"
CW20-1D
ONE LANE CLOSED
2-LANE ROADWAY WITH PAVED SHOULDERS
24" X 24"
CW1-4L
48" X 48"XXX100' Approx.100'50'-30'Min.30'Min.1/2 L 1/3 LXXX48" X 48"
CW20-1D
See note 1)
(Flags-
24" X 30"
R4-1
CW1-4R
48" X 48"
G20-2
Edgeline
White
4" Solid
Island
in Buffer
Yellow
4" Double
Yellow Line
4" Double
+4"
40' C-C.
Markers on
Pavement
Raised
Type II-A-A
1"-2"Paved ShoulderPaved Shoulderlights. (See notes 7 & 8)
oscillating or strobe
rotating, flashing,
TMA and high intensity
Shadow Vehicle with
CW1-4L
48" X 48"
G20-2
48" X 24"
CW1-4L
48" X 48"
2-LANE ROADWAY WITH PAVED SHOULDERS
ONE LANE CLOSED
INADEQUATE FIELD OF VIEWADEQUATE FIELD OF VIEW XCW1-4L
CW20-1D
48" X 48"
CW1-4R
CW1-4R
X 1/3 L24" X 24"
CW13-1P
24" X 24"
CW13-1P
CW1-6aT
36" X 36"
(See note 2)CW13-1P
CW1-6aT
36" X 36"
(See note 2)
24" X 24"
CW13-1P
CW1-6aT
36" X 36"
24" X 24"
CW13-1P
CW1-6aT
36" X 36"
24" X 24"
CW13-1P CW13-1P
CW1-6aT
36" X 36"
(See note 2)
If applicable
If applicable
24" X 30"
R4-2
G20-2
48" X 24"
If applicable
24" X 30"
R4-2
GENERAL NOTES
48" X 24"
24" X 30"
R4-2
24" X 24"
48" X 48"
24" X 30"
R4-1
TCP (2-3a)
48" X 48"
TCP(2-3b)ONLY
TERM STATIONARY
INTERMEDIATE
STATIONARY
LONG TERM
STATIONARY
SHORT TERM
TYPICAL USAGE
MOBILE DURATION
SHORT
Type 3 Barricade
Heavy Work Vehicle
Channelizing Devices
Flag
LEGEND
Flagger
Sign
Flashing Arrow Board
Trailer Mounted
Traffic Flow
Attenuator (TMA)
Truck Mounted
Markers Ty II-AA
Raised Pavement
L=Length of Taper(FT) W=Width of Offset(FT) S=Posted Speed(MPH)
Taper lengths have been rounded off.
Conventional Roads Only*
**
2
***
75 750'
720'
825'900'75'900'540'
90'
120'
155'
195'
240'
295'
350'
410'
475'
60'
70'
80'
90'
100'
110'
120'
130'
140'
150'
120'
160'
240'
320'
400'
500'
700'
600'
800'
30'
35'
40'
45'
50'
55'
60'
65'
70'
150'
205'
265'
450'
500'
550'
600'
165'
225'
295'
495'
550'
605'
660'
180'
320'
600'
660'
650'715'780'
245'
540'
700'770'840'
30
35
40
45
50
55
60
65
70
60
WS
L=
Posted
Speed
"B"
Buffer Space
Longitudinal
Suggested
Tangent
On a
Taper
On a12'
OffsetOffset
11'
Offset
10'
Taper Lengths
Desirable
Minimum
Devices
Channelizing
Spacing of
Suggested Maximum
Formula
L=WS
Spacing
Sign
Minimum
Distance
"X"
24" X 24"
CW13-1P
If applicable
work spaces
areas betweem recurrent
1/4 to 1/2 mile in rural
1000' in urban areas, or
Devices spaced at 500' to
Transverse Channelizing
is intended for the area of the conflicting markings, not the entire work zone.
sections, at 1/2(S) where S is the speed in mph. This tighter device spacing
tapers at 20' or 15' if posted speeds are 35 mph or slower, and for tangent
channelizing devices which separate two-way traffic should be spaced on
For shorter durations where traffic is directed over a yellow centerline,
9. Conflicting pavement markings shall be removed for long-term projects.
next to those shown in order to protect a wider work space.
8. Additional Shadow Vehicles with TMAs may be positioned off the paved surface,
in place, Type 3 Barricades or other channelizing devices may be substituted.
present but road or work conditions require the traffic control to remain
affecting the performance or quality of the work. If workers are no longer
30 to 100 feet in advance of the area of crew exposure without adversely
7. A Shadow Vehicle with a TMA should be used anytime it can be positioned
6. Conflicting pavement marking shall be removed for long term projects.
AHEAD" signs. Proper spacing of signs shall be maintained.
regulatory speed zone signs may be installed within CW20-1D "ROAD WORK
5. The R4-1 "DO NOT PASS," R4-2 " PASS WITH CARE" and construction
be positioned at end of traffic queue.
volume require additional emphasis to safely control traffic. Flagger should
4. Flagger control should NOT be used unless roadway conditions or heavy traffic
traffic.
markings may remain in place. Channelizing devices shall be used to separate
3. When work space will be in place less than three days existing pavement
or for routine maintenance work, when approved by the Engineer.
with the triangle symbol may be omitted when stated elsewhere in the plans,
2. All traffic control devices illustrated are REQUIRED, except those denoted
1. Flags attached to signs where shown, are REQUIRED.
See note 1)
(Flags-
48" X 48"
TWO-LANE ROADS
TRAFFIC SHIFTS ON
TRAFFIC CONTROL PLAN
8-95
1-97 2-12
4-98
3-03
163
December 1985
Standard
Division
Operations
TrafficShoulderShoulder200'Approx. 1/2 LShoulderShoulderXXX 1/3 LLLWork SpaceMin.30'B 1/2 LXXXXLBXX100'Approx.XWork Space3X for over 50 MPHX for 50 MPH or lessTCP(2-4)-18
45
tcp2-4-18.dgn
2-18
DN:CK:DW:CK:FILE:
---
-
JOB
COUNTY
SECT
DIST
REVISIONS
-
HIGHWAY
-
SHEET NO.
C TxDOT
of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:CONT FILE:DATE:$FILE$$DATE$$TIME$Shoulder30'MIN.XTCP (2-4b)TCP (2-4a)
ONE LANE CLOSED TWO LANES CLOSEDShoulderShoulderLB
48" X 24"
G20-2
CW20-5TL
48" X 48"
48" X 24"
G20-2
CW20-1D
48" X 48"
See note 1)
(Flags-
48" X 24"
G20-2
CW20-1D
48" X 48"
See note 1)
(Flags-
CW1-4L
48" X 48"
36" X 36"
CW1-4R
48" X 48"
48" X 24"
G20-2
XXX 1/3 L(See note 4)
30" X 12"
CW16-3aP
CW20-5TR
48" X 48"
CW20-5TR
48" X 48"
(See note 4)
30" X 12"
CW16-3aP
CW20-1D
48" X 48"
See note 1)
(Flags-
24" X 24"Shoulderlights.(See notes 5 & 6)
oscillating or strobe
rotating, flashing,
TMA and high intensity
Shadow Vehicle with
(See note 8)
(See notes 5 & 6)
strobe lights.
oscillating or
rotating, flashing,
high intensity
with TMA and
Shadow Vehicle
CW20-1D
48" X 48"
See note 1)
(Flags-
note 4)
(See
30" X 12"
CW16-3aP
CW1-6aT
36" X 36"
24" X 24"
CW13-1P
CW1-6aT
CW13-1P
Type 3 Barricade
Heavy Work Vehicle
Channelizing Devices
Flag
LEGEND
Flagger
Sign
Message Sign (PCMS)
Portable Changeable
Flashing Arrow Board
Trailer Mounted
M
Traffic Flow
Attenuator (TMA)
Truck Mounted
L=Length of Taper(FT) W=Width of Offset(FT) S=Posted Speed(MPH)
Taper lengths have been rounded off.
Conventional Roads Only*
**
2
***
75 750'
720'
825'900'75'900'540'
90'
120'
155'
195'
240'
295'
350'
410'
475'
60'
70'
80'
90'
100'
110'
120'
130'
140'
150'
120'
160'
240'
320'
400'
500'
700'
600'
800'
30'
35'
40'
45'
50'
55'
60'
65'
70'
150'
205'
265'
450'
500'
550'
600'
165'
225'
295'
495'
550'
605'
660'
180'
320'
600'
660'
650'715'780'
245'
540'
700'770'840'
30
35
40
45
50
55
60
65
70
60
WSL=
Posted
Speed
"B"
Buffer Space
Longitudinal
Suggested
Tangent
On a
Taper
On a12'
OffsetOffset
11'
Offset
10'
Taper Lengths
Desirable
Minimum
Devices
Channelizing
Spacing of
Suggested Maximum
Formula
L=WS
Spacing
Sign
Minimum
Distance
"X"
TERM STATIONARY
INTERMEDIATE
STATIONARY
LONG TERM
STATIONARY
SHORT TERM
TYPICAL USAGE
MOBILE DURATION
SHORT
TCP (2-4a)
TCP (2-4b)
GENERAL NOTES
the area of conflicting markings, not the entire work zone.
1/2(S) where S is the speed in mph. This tighter devices spacing is intended for
at 20' or 15' if posted speeds are 35 mph or slower, and for tangent sections, at
channelizing devices which separate two-way traffic should be spaced on tapers
8. For shorter durations where traffic is directed over a yellow centerline,
closed lane near the end of the merging taper.
protect the work space from opposing traffic with the arrow board placed in the
shall be used and channelizing devices shall be placed on the centerline to
7. If this TCP is used for a left lane closure, CW20-5TL "LEFT LANE CLOSED"signs
to protect a wider work space.
lane, on the shoulder or off the paved surface, next to those shown in order
6. Additional Shadow Vehicles with TMAs may be positioned in each closed
Vehicle and TMA.
Barricades or other channelizing devices may be substituted for the Shadow
or work conditions require the traffic control to remain in place, Type 3
the performance or quality of the work. If workers are no longer present but road
30 to 100 feet in advance of the area of crew exposure without adversely affecting
5. A Shadow Vehicle with a TMA should be used anytime it can be positioned
plaque.
legend may be shown on the sign face rather than on a CW16-3aP supplemental
4. For short term applications, when post mounted signs are not used, the distance
length per lane.
3. The downstream taper is optional. When used, it should be 100 feet minimum
or for routine maintenance work, when approved by the Engineer.
with the triangle symbol may be omitted when stated elsewhere in the plans,
2. All traffic control devices illustrated are REQUIRED, except those denoted
1. Flags attached to signs where shown, are REQUIRED.
CONVENTIONAL ROADS
LANE CLOSURES ON MULTILANE
TRAFFIC CONTROL PLAN
December 1985
2-12
8-95
1-97
4-98
3-03
164
Standard
Division
Operations
Traffic3X for over 50 MPHX for 50 MPH or lessShoulderShoulder46
TCP(2-5)-18
2-18
tcp2-5-18.dgn DN:CK:DW:CK:FILE:
---
-
JOB
COUNTY
SECT
DIST
REVISIONS
-
HIGHWAY
-
SHEET NO.
C TxDOT
of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:CONT FILE:DATE:$FILE$$DATE$$TIME$Type 3 Barricade
Heavy Work Vehicle
Channelizing Devices
Flag
LEGEND
Flagger
Sign
Message Sign (PCMS)
Portable Changeable
Flashing Arrow Board
Trailer Mounted
M
Traffic Flow
Attenuator (TMA)
Truck Mounted 30'MIN.X 1/3 LWork SpaceBBBWork SpaceL 1/2 LCW20-1D
See note 1)
(Flags-
48" X 48"XL100'Approx.ShoulderShoulderShoulderShoulder200'Approx.Min.30'
48" X 24"
G20-2
CW20-1D
48" X 48"
See note 1)
(Flags-
48" X 24"
G20-2
XXXXLLXXXXX1/3 L20' spacingdevices at 1/2 L Min.
CW20-5TR
48" X 48"
48" X 48"
CW1-4L
36" X 36"
CW20-1D
48" X 48"
See note 1)
(Flags-
CW20-5TL
48" X 48"
CW20-1D
48" X 48"
See note 1)
(Flags-
48" X 24"
G20-2
TCP (2-5b)TCP (2-5a)
ONE LANE CLOSED TWO LANES CLOSED
lights.(See notes 3 & 4)
oscillating or strobe
rotating, flashing,
TMA and high intensity
Shadow Vehicle with
48" X 24"
G20-2
30" X 12"
CW16-3aP
24" X 24"
30" X 12"
CW16-3aP
CW20-5TR
48" X 48"
30" X 12"
CW16-3aP
ShoulderShoulderXX48" X 48"
CW1-4R
(See notes 3 & 4)
or strobe lights.
oscillating
flashing,
intensity rotating,
TMA and high
Shadow Vehicle with
CW13-1P
CW1-6aT
CW1-6aT
36" X 36"
24" X 24"
CW13-1P
Markings
Pavement
Markings
Pavement
TCP (2-5a)
GENERAL NOTES
TERM STATIONARY
INTERMEDIATE
STATIONARY
LONG TERM
STATIONARY
SHORT TERM
TYPICAL USAGE
MOBILE DURATION
SHORT
TCP (2-5b)
L=Length of Taper(FT) W=Width of Offset(FT) S=Posted Speed(MPH)
Taper lengths have been rounded off.
Conventional Roads Only*
**
2
***
75 750'
720'
825'900'75'900'540'
90'
120'
155'
195'
240'
295'
350'
410'
475'
60'
70'
80'
90'
100'
110'
120'
130'
140'
150'
120'
160'
240'
320'
400'
500'
700'
600'
800'
30'
35'
40'
45'
50'
55'
60'
65'
70'
150'
205'
265'
450'
500'
550'
600'
165'
225'
295'
495'
550'
605'
660'
180'
320'
600'
660'
650'715'780'
245'
540'
700'770'840'
30
35
40
45
50
55
60
65
70
60
WSL=
Posted
Speed
"B"
Buffer Space
Longitudinal
Suggested
Tangent
On a
Taper
On a12'
OffsetOffset
11'
Offset
10'
Taper Lengths
Desirable
Minimum
Devices
Channelizing
Spacing of
Suggested Maximum
Formula
L=WS
Spacing
Sign
Minimum
Distance
"X"
7. Conflicting pavement markings shall be removed for long-term projects.
taper.
arrow board placed in the closed lane near the end of the merging
centerline to protect the work space from opposing traffic, with the
signs shall be used and channelizing devices shall be placed on the
6. If this TCP is used for a left lane closure, CW20-5TL "LEFT LANE CLOSED"
approximately per lane, with channelizing devices spaced at 20 feet.
5. The downstream taper is optional. When used, it should be 100 feet
shown in order to protect a wider work space.
closed lane, on the shoulder or off the paved surface, next to those
4. Additional Shadow Vehicles with TMAs may be positioned in each
channelizing devices may be substitutued for the Shadow Vehicle and TMA.
require the traffic control to remain in place, Type 3 Barricades or other
If workers are no longer present but road or work conditions
without adversely affecting the performance or quality of the work.
positioned 30 to 100 feet in advance of the area of crew eposure
3. A Shadow Vehicle with a TMA should be used anytime it can be
the plans, or for routine maintenance work, when approved by the Engineer.
denoted with the triangle symbol may be omitted when stated elsewhere in
2. All traffic control devices illustrated are REQUIRED, except those
1. Flags attached to signs where shown, are REQUIRED.
MULTILANE CONVENTIONAL RDS.
LONG TERM LANE CLOSURES
TRAFFIC CONTROL PLAN
December 1985
2-128-95
1-97
4-98
3-03
165
Standard
Division
Operations
Traffic
TCP(2-6)-18
472-18
tcp2-6-18.dgn DN:CK:DW:CK:FILE:
---
-
JOB
COUNTY
SECT
DIST
REVISIONS
-
HIGHWAY
-
SHEET NO.
C TxDOT
of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:CONT
FILE:DATE:$FILE$$DATE$$TIME$MedianShoulderShoulderMedianShoulderWork SpaceBBWork SpaceWork SpaceB1000'100'TCP (2-6a)2600'1000'1600'1/3 LL500' Min.1/3 LLL30'Min.500' Min. MedianShoulderShoulder
48" X 24"
G20-2
30" X 12"
CW16-3aP
30" X 12"
CW16-3aPShoulder
ONE LANE CLOSURE
TCP (2-6b)TCP (2-6c)
LANE CLOSURE NEAR ENTRANCE RAMPS
48" X 24"
G20-2
48" X 42"
E5-1
500'FRONTAGE RD.1/3 LLMin.30'48" X 48"
CW20RP-3D500' min.
48" X 24"
G20-2
20' spacing
Devices at
Channelizing
(See notes 5)
Marking
Pavement ShoulderLANE CLOSURE NEAR EXIT RAMPS30' Min. Min.10'Min.
6 & 7)
(See notes (See notes 6 & 7)
the ramp.
required to enter
which is normally
to close a lane
closure is needed
details if a lane
for lane closure
See TCP(2-5a)
48" X 48"
CW20-5TR
48" X 48"
CW20-5TR
48" X 48"
CW25-1T
6 & 7)
(See notes Approx.100'Approx.100'Approx.100'48" X 30"
R11-2bT
CW20-1F
48" X 48"
See note 1)
(Flags-
48" X 42"
E5-1
(See note 5)
Marking
Pavement
(See note 5)
Marking
Pavement
(See note 5)
Marking
Pavement
for lane closure
warning signs
for advance
See TCP(2-6a)
for lane closure
warning signs
for advance
See TCP(2-6a)
48" X 60"
CW13-2
Type 3 Barricade
Heavy Work Vehicle
Channelizing Devices
Flag
LEGEND
Flagger
Sign
Message Sign (PCMS)
Portable Changeable
Flashing Arrow Board
Trailer Mounted
M
Traffic Flow
Attenuator (TMA)
Truck Mounted
L=Length of Taper(FT) W=Width of Offset(FT) S=Posted Speed(MPH)
Taper lengths have been rounded off.
Conventional Roads Only*
**
2
***
75 750'
720'
825'900'75'900'540'
90'
120'
155'
195'
240'
295'
350'
410'
475'
60'
70'
80'
90'
100'
110'
120'
130'
140'
150'
120'
160'
240'
320'
400'
500'
700'
600'
800'
30'
35'
40'
45'
50'
55'
60'
65'
70'
150'
205'
265'
450'
500'
550'
600'
165'
225'
295'
495'
550'
605'
660'
180'
320'
600'
660'
650'715'780'
245'
540'
700'770'840'
30
35
40
45
50
55
60
65
70
60
WSL=
Posted
Speed
"B"
Buffer Space
Longitudinal
Suggested
Tangent
On a
Taper
On a12'
OffsetOffset
11'
Offset
10'
Taper Lengths
Desirable
Minimum
Devices
Channelizing
Spacing of
Suggested Maximum
Formula
L=WS
Spacing
Sign
Minimum
Distance
"X"
TERM STATIONARY
INTERMEDIATE
STATIONARY
LONG TERM
STATIONARY
SHORT TERM
TYPICAL USAGE
MOBILE DURATION
SHORT
shown in order to protect a wider work space.
closed lane, on the shoulder or off the paved surface, next to those
7. Additional Shadow Vehicles with TMAs may be positioned in each
Shadow Vehicle and TMA.
Barricades or other channelizing devices may be substituted for the
conditions require the traffic control to remain in place, Type 3
or quality of the work. If workers are no longer present but road or work
of the area of crew exposure without adversely affecting the performance
should be used anytime it can be positioned 30 to 100 feet in advance
flashing, oscillating or strobe lights. A Shadow Vehicle with a TMA
or strobe lights. Shadow Vehicle with TMA and high intensity rotating,
6. Shadow Vehicle with TMA and high intensity rotating, flashing,oscillating
stationary work zones with the approval of the Engineer.
5. The placement of pavement markings may be omitted on Intermediate-term
least two VPs, the VPs may be placed on each channelizing device.
channelizing device. If night time conditions make it difficult to see at
may be supplemented with vertical panels (VP) placed on everyother
4. Channelizing devices used along the work space or along tangent sections
device. Chevrons may be attached to plastic drums as per BC Standards.
with the Chevron Alignment Sign placed on every other channelizing
3. Channelizing devices used to close lanes may be supplemented
the plans, or for routine maintenance work, when approved by the Engineer.
denoted with the triangle symbol may be omitted when stated elsewhere in
2. All traffic control devices illustrated are REQUIRED, except those
1. Flags attached to signs where shown, are REQUIRED.
GENERAL NOTES
DIVIDED HIGHWAYS
LANE CLOSURES ON
TRAFFIC CONTROL PLAN
2-12
2-94
8-95
1-97
4-98
166
December 1985
Standard
Division
Operations
Traffic
2-18
tcp2-7-18.dgn
TCP(2-7)-18
48
DN:CK:DW:CK:FILE:
---
-
JOB
COUNTY
SECT
DIST
REVISIONS
-
HIGHWAY
-
SHEET NO.
C TxDOT
of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:CONT
FILE:DATE:$FILE$$DATE$$TIME$XXXXXX10'TCP (2-7b)
shown for one direction
Traffic Control Devices
Edgeline
White
4" Solid
Markers
Object
OM-3
(See note 5)
this point.
extend to
surface should
New pavement
space.
enter and exit work
and equipment to
offset to permit workers
Barricades may be
Yellow Line
4" Double
+4"
40' C-C.
Markers on
Pavement
Raised
Type II-A-A
1"-2"
CW20-1D
48" X 48"
See note 1)
(Flags-
48" X 48"
CW20-1A,B or C
CW20-1D
48" X 48"
See note 1)
(Flags-
(See note 2)
24" X 24"
CW1-4L
48" X 48"
48" X 24"
G20-2
48" X 24"
CW1-6
48" X 30"
R11-2
Yellow Line
4" Double +4"
40' C-C.
Markers on
Pavement
Raised
Type II-A-A
1"-2"
TCP (2-7a)
ROADWAY DIVERSION
(See note 2)
this point.
extend to
surface should
New pavement
48" X 24"
G20-2
24" X 30"
R4-2
in the plans.
detailed elsewhere
barrier system as
treatment, or other
CTB with safety end
24" X 30"
R4-1
(See note 6)
48" X 48"
CW5-2
shown for one direction
Traffic Control Devices
BRIDGE WIDENING
(See note 2)
48" X 24"
CW1-6
(See note 2)
48" X 24"
CW1-6
Edgeline
White
4" Solid
(Both directions)
channelizing devices are used.
be added if drums or longitudinal
steady-burn warning lights may
Warning Reflectors, chevrons or
additional conspicuity at night.
top of channelizing devices for
Warning Reflectors may be added on
48" X 48"
CW1-4R
24" X 24"
CW13-1P
CW13-1P
If applicable
GENERAL NOTES
TCP (2-7b)
TCP (2-7a)
TERM STATIONARY
INTERMEDIATE
STATIONARY
LONG TERM
STATIONARY
SHORT TERM
TYPICAL USAGE
MOBILE DURATION
SHORT
Heavy Work Vehicle
Channelizing Devices
Flag
LEGEND
Flagger
Sign
Flashing Arrow Board
Trailer Mounted
Traffic Flow
Attenuator (TMA)
Truck Mounted
Markers Ty II-AA
Raised Pavement
Type 3 Barricade
L=Length of Taper(FT) W=Width of Offset(FT) S=Posted Speed(MPH)
Taper lengths have been rounded off.
Conventional Roads Only*
**
2
***
75 750'
720'
825'900'75'900'540'
90'
120'
155'
195'
240'
295'
350'
410'
475'
60'
70'
80'
90'
100'
110'
120'
130'
140'
150'
120'
160'
240'
320'
400'
500'
700'
600'
800'
30'
35'
40'
45'
50'
55'
60'
65'
70'
150'
205'
265'
450'
500'
550'
600'
165'
225'
295'
495'
550'
605'
660'
180'
320'
600'
660'
650'715'780'
245'
540'
700'770'840'
30
35
40
45
50
55
60
65
70
60
WS
L=
Posted
Speed
"B"
Buffer Space
Longitudinal
Suggested
Tangent
On a
Taper
On a12'
OffsetOffset
11'
Offset
10'
Taper Lengths
Desirable
Minimum
Devices
Channelizing
Spacing of
Suggested Maximum
Formula
L=WS
Spacing
Sign
Minimum
Distance
"X"
widths are maintained.
6. The CW5-2 "Narrow Bridge" sign may be omitted if lane and shoulder
marking.
during project do not conflict with construction area pavement
edge to a point where existing pavement markings left in place
5. New pavement surface should be extended across existing roadway
speed limit or prevailing speed.
4. Roadway diversion design requirements should be based on posted
throughout project.
3. Raised pavement markers shall be placed 40 feet c-c on centerline
Engineer.
in the plans, or for routine maintenance work, when approved by the
denoted with the triangle symbol may be omitted when stated elsewhere
2. All traffic control devices illustrated are REQUIRED, except those
1. Flags attached to signs where shown are REQUIRED.
NARROW BRIDGES
DIVERSIONS AND
TRAFFIC CONTROL PLAN
8-95
1-97
4-98
2-12
3-03
167
December 1985
Standard
Division
Operations
Traffic
49
tcp2-8-18.dgn
2-18
TCP(2-8)-18
DN:CK:DW:CK:FILE:
---
-
JOB
COUNTY
SECT
DIST
REVISIONS
-
HIGHWAY
-
SHEET NO.
C TxDOT
of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:CONT
FILE:DATE:$FILE$$DATE$$TIME$100'50'-100'100' Max.TCP (2-8a)TCP (2-8b)XXXXX50' - 100'100'-150'150'40' toXXXX50'-100'100'-150'150'40' todirection)
in the opposing
DO NOT PASS sign
from the R4-1
be located across
(This sign shouldX
100' Max.R1-2
48" X 36"
R1-2aP
(See note 7)
24" X 30"
R4-1
See note 1)
(Flags-
CW20-1D
48" X 48"
ONE LANE TWO-WAY
TRAFFIC CONTROL WITH YIELD SIGNS
R1-2
R1-2aP
48" X 36"
42" X 42 " X 42"
(See note 7)
48" X 24"
G20-2
24" X 30"
R4-2
48" X 48"
48" X 48"
(See note 2)
48" X 48"
CW20-4D
48" X 48"
CW1-4R
Yield Line
Temporary
Yield Line
Temporary
24" X 30"
R4-1
48" X 48"
48" X 48"
CW1-4R
(See note 2)
48" X 48"
CW20-4D
24" Stop Line
Temporary
24" X 36"
R10-6L
48" X 24"
G20-2
24" X 30"
R4-2
ONE LANE TWO-WAY
TRAFFIC CONTROL WITH TRAFFIC SIGNAL
24" X 36"
R10-6L
24" Stop Line
Temporary
CW5-3
CW5-3
OR
OR
+4"
1"-2"40' C-C.
Markers on
Pavement
Raised
Type II-A-A
Yellow Line
4" Double +4"
1"-2"40' C-C.
Markers on
Pavement
Raised
Type II-A-A
Yellow Line
4" Double
Edgeline
White
4" Solid
Edgeline
White
4" Solid
Edgeline
White
4" Solid
same as below
in opposite direction
Warning Sign Sequence
(Less Than 2000 ADT-See Note 5)
11' - Rural
10' - Urban (Urban Street
Speed Conditions 30-40 mph)
11' - Rural
10' - Urban (Urban Street
Speed Conditions 30-40 mph)
42"X 42"X 42"
(See note 6)
Beacon.
Light or Flashing
Flashing Warning
Intensity
Type B High
same as below
in opposite direction
Warning Sign Sequence
CW20-1D
48" X 48"
See note 1)
(Flags-
24" X 24"
CW13-1P
24" X 24"
CW13-1P
24" X 24"
CW13-1P
(Red Ball on Top)
48" X 48"
24" X 24"
CW13-1P
CW3-2
MINIMUM LANE WIDTH
MINIMUM LANE WIDTH
CW3-3
If applicable
GENERAL NOTES
TCP (2-8a)
TCP (2-8b)
TERM STATIONARY
INTERMEDIATE
STATIONARY
LONG TERM
STATIONARY
SHORT TERM
TYPICAL USAGE
MOBILE DURATION
SHORT
Traffic Signal
Temporary or Portable
Markers Ty II-AA
Raised Pavement
Channelizing Devices
Flag
LEGEND
Flagger
Sign Traffic Flow
Type 3 Barricade
L=Length of Taper(FT) W=Width of Offset(FT) S=Posted Speed(MPH)
Taper lengths have been rounded off.
Conventional Roads Only*
**
2
***
75 750'
720'
825'900'75'900'540'
90'
120'
155'
195'
240'
295'
350'
410'
475'
60'
70'
80'
90'
100'
110'
120'
130'
140'
150'
120'
160'
240'
320'
400'
500'
700'
600'
800'
30'
35'
40'
45'
50'
55'
60'
65'
70'
150'
205'
265'
450'
500'
550'
600'
165'
225'
295'
495'
550'
605'
660'
180'
320'
600'
660'
650'715'780'
245'
540'
700'770'840'
30
35
40
45
50
55
60
65
70
60
WSL=
Posted
Speed
"B"
Buffer Space
Longitudinal
Suggested
Tangent
On a
Taper
On a12'
OffsetOffset
11'
Offset
10'
Taper Lengths
Desirable
Minimum
Devices
Channelizing
Spacing of
Suggested Maximum
Formula
L=WS
Spacing
Sign
Minimum
Distance
"X"Distance
Sight
Stopping
200'
250'
305'
360'
425'
495'
570'
645'
730'
820'
distance for approaching motorist (See table above).
9. Portable traffic signals should be located to provide adequate stopping sight
Work Zone Traffic Control Devices" list.
8. A list of approved Portable Traffic Signals can be found in the "Compliant
regulatory signs shall be installed at 7 foot minimum mounting height.
7. The R1-2 "YIELD" and R1-2aP "TO ONCOMING TRAFFIC" signs and other
"YIELD AHEAD" symbol sign for emphasis.
6. If power is available, a flashing beacon should be attached to the CW3-2
traffic signals should be used.
400 feet long and roadways with less than 2000 ADT. Otherwise, portable
traffic control operations should be limited to work spaces less than
5. Traffic control by CW3-2 "YIELD AHEAD" symbol signs for one lane two-way
intended for the area of conflicting information and not the entire work zone.
recommended. The 20 foot channelizing device spacing recommendation is
In such locations a maximum channelizing device spacing of 20 feet is
information, such as where traffic is directed over a double yellow centerline.
close spacing. This is especially important in locations of conflicting
pavement markings, the channelization must be made dominant by using a very
4. For intermediate term situations, when it is not feasible to remove and restore
DO NOT PASS signs and stop or yield lines.
3. Raised pavement markers shall be placed 40 feet c-c on centerline between
is required with either warning sign.
of the CW5-3 "ONE LANE BRIDGE" signs. The CW13-1P Advisory Speed Plaque
a 48" x 48" CW20-4D "ONE LANE ROAD AHEAD" signs should be used in lieu
2. When this TCP is used at a location which does not involve a bridge,
1. Flags attached to signs where shown are REQUIRED.
TWO-WAY CONTROL
LONG TERM ONE-LANE
TRAFFIC CONTROL PLAN
December 1985
2-12
8-95
1-97
4-98
3-03
168
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
TYPICAL SECTIONS
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDT01.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDT01.dgn1:404:38:30 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837NTS
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
LC
TYP.
6"
50
CURB
EXISTING GROUND
6"
TYP. GROUND
EXISTING
2% MAX
1.5% TYP.
McKINNEY STREET TYPICAL SECTION
12"
TYP.
6:1 MAX
EX. R.O.W VARIES
6:1 MAX
1.5% TYP.
N.T.S.STATION 90+79.49 TO 93+60.58
2% MAX
1.5% TYP.R.O.W.EX. R.O.W.EX. 3:1 MAX
4:1 TYP.
& GUTTER (TYP.)
STANDARD CURB
SLOPE TRANSITION TO 2.00%SLOPE TRANSITION TO 2.00%
VARIES 2.5'-7'
VARIES
BIKE/PED PATH
12' FUTURE
2'
LANE
14'
6:1 MAX
1.5% TYP.
PGL RT
PGL LT
BUFFER
STRIPED
VARIES
WIDTH WIDTH VARIES
THRU LANE
TURN LANE
13'
5.5'FUTURE LANE
STRIPED
WIDTH VARIES
LC
6" GROUND
EXISTING
31.5' RT
PGL RT 25.5' LT
PGL LT
100' EX. R.O.W
TYP.
12"
TYP.
6"
LANE
11'
LANE
11'
TWO-WAY LEFT
12'
TURN LANE
(TYP.)
GUTTER
CURB &
STANDARD
SIDEWALK
TYP.
LANE
11'
LANE
11'
2.00%
3" ASPHALT SURFACE (TYPE C)
3" ASPHALT BASE (TYPE B)
6" ASPHALT BASE (TYPE B)
EXISTING GROUNDR.O.W.EX. R.O.W.EX. 57' B-B
2% MAX
1.5% TYP.
6:1 MAX
3:1 MAX
4:1 TYP.
2'
5.5'
6:1 MAX
1.5% TYP.
6:1 MAX
1.5% TYP.
3:1 MAX
4:1 TYP.
& GUTTER (TYP.)
STANDARD CURB
2% MAX
1.5% TYP.
FUTURE
6'
7'-9.5'
BIKE/PED PATH
12' FUTURE
FUTURE
6'
SIDEWALK
2.00%
3'
3'
5'
3'-5.5'
BE USED FOR SUBGRADE PREP.
WILL ADVISE CONTRACTOR ON MATERIAL TO
SUBGRADE PREPARATION. CITY INSPECTOR
SOIL MATERIAL VIA TESTING PRIOR TO
OCTOBER 10, 2018. CONTRACTOR TO VERIFY
PUBLISHED BY TERRACON CONSULTANTS ON
GEOTECHNICAL REPORT NO. 94175295
SUBGRADE PREP. INSTRUCTIONS PER
3" ASPHALT SURFACE (TYPE C)
3" ASPHALT BASE (TYPE B)
6" ASPHALT BASE (TYPE B)
12" STABILIZED SUBGRADE*
12" STABILIZED SUBGRADE*
TURN LANE
12.5'
WIDTH VARIES
THRU LANE
McKINNEY STREET TYPICAL SECTION - TWO WAY LEFT TURN LANE
N.T.S. STATION 93+60.58 TO 104+50.00
AND NO. 3 BARS @ 18" O.C.E.W
SIDEWALK W/ 3000 PSI CONC
6" REINF. CONCRETE
AND NO. 3 BARS @ 18" O.C.E.W
W/ 3000 PSI CONCRETE
6" REINF. CONCRETE SIDEWALK
AND NO. 3 BARS @ 18" O.C.E.W
W/ 3000 PSI CONCRETE
4" REINF. CONCRETE SIDEWALK
AND NO. 3 BARS @ 18" O.C.E.W
W/ 3000 PSI CONCRETE
4" REINF. CONCRETE SIDEWALK
*SUBGRADE NOTES
LIME STABILIZE (36 LB/SY/6" LIFT)
154+50:
BORE #9 (APPROX. STA 128+00) TO STA
(24 LB/SY/6" LIFT)
SAND OR CLAYEY SAND=CEMENT STABILIZE
LIFT)
CLAY SOIL=LIME STABILIZE (36 LB/SY/6"
#9 (APROX. STA. 128+00):
BORE #8 (APPROX. STA. 114+00) TO BORE
FLEX BASE TY-D GR 1-2
CONCENTRATION=REPLACE SUBGRADE WITH 12"
FIELD TEST >3000 PPM SULFATE
(24 LB/SY/6" LIFT)
SAND OR CLAYEY SAND=CEMENT STABILIZE
LIFT)
CLAY SOIL=LIME STABILIZE (36 LB/SY/6"
#8 (APPROX. STA. 114+00:
BORE #7 (APPROX. STA. 100+50) TO BORE
FLEX BASE TY-D GR 1-2
CONCENTRATION=REPLACE SUBGRADE WITH 12"
FIELD TEST >3000 PPM SULFATE
LIFT)
CLAY SOIL=LIME STABILIZE (36 LB/SY/6"
100+50):
STA 90+79.49 TO BORE #7 (APPROX. STA.
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
TYPICAL SECTIONS
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDT02.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDT02.dgn1:404:38:32 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837NTS
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
51
LC
6"
GROUND
EXISTING
31.5' RT
PGL RT 25.5' LT
PGL LT
100' EX. R.O.W
TYP.
12"
TYP.
6"
LANE
11'
LANE
11'
TWO-WAY LEFT
12'
TURN LANE
(TYP.)
GUTTER
CURB &
STANDARD
SIDEWALK
TYP.
LANE
11'
LANE
11'
2.00%
EXISTING GROUNDR.O.W.EX. R.O.W.EX. 57' B-B
2% MAX
1.5% TYP.
6:1 MAX
3:1 MAX
4:1 TYP.
2'
5.5'
6:1 MAX
1.5% TYP.
6:1 MAX
1.5% TYP.
3:1 MAX
4:1 TYP.
& GUTTER (TYP.)
STANDARD CURB
2% MAX
1.5% TYP.
FUTURE
6'
7'-9.5'
BIKE/PED PATH
12' FUTURE
LC
6" GROUND
EXISTING
31.5' RT
PGL RT 25.5' LT
PGL LT
100' EX. R.O.W
TYP.
12"
TYP.
6"
LANE
11'
LANE
11'
TWO-WAY LEFT
12'
TURN LANE
(TYP.)
GUTTER
CURB &
STANDARD
SIDEWALK
TYP.
LANE
11'
LANE
11'
EXISTING GROUNDR.O.W.EX. R.O.W.EX. 57' B-B
2% MAX
1.5% TYP.
6:1 MAX
3:1 MAX
4:1 TYP.
2'
5.5'
6:1 MAX
1.5% TYP.
6:1 MAX
1.5% TYP.
3:1 MAX
4:1 TYP.
& GUTTER (TYP.)
STANDARD CURB
2% MAX
1.5% TYP.
FUTURE
6'
7'-9.5'
BIKE/PED PATH
12' FUTURE
VARIES*2.00%
2.00%
3'
3'
5'
3'-5.5'
3'-5.5'
5'
BE USED FOR SUBGRADE PREP.
WILL ADVISE CONTRACTOR ON MATERIAL TO
SUBGRADE PREPARATION. CITY INSPECTOR
SOIL MATERIAL VIA TESTING PRIOR TO
OCTOBER 10, 2018. CONTRACTOR TO VERIFY
PUBLISHED BY TERRACON CONSULTANTS ON
GEOTECHNICAL REPORT NO. 94175295
SUBGRADE PREP. INSTRUCTIONS PER
3" ASPHALT SURFACE (TYPE C)
3" ASPHALT BASE (TYPE B)
6" ASPHALT BASE (TYPE B)
3" ASPHALT SURFACE (TYPE C)
3" ASPHALT BASE (TYPE B)
6" ASPHALT BASE (TYPE B)
12" STABILIZED SUBGRADE*
12" STABILIZED SUBGRADE*
*SUBGRADE NOTES
LIME STABILIZE (36 LB/SY/6" LIFT)
154+50:
BORE #9 (APPROX. STA 128+00) TO STA
(24 LB/SY/6" LIFT)
SAND OR CLAYEY SAND=CEMENT STABILIZE
LIFT)
CLAY SOIL=LIME STABILIZE (36 LB/SY/6"
#9 (APROX. STA. 128+00):
BORE #8 (APPROX. STA. 114+00) TO BORE
FLEX BASE TY-D GR 1-2
CONCENTRATION=REPLACE SUBGRADE WITH 12"
FIELD TEST >3000 PPM SULFATE
(24 LB/SY/6" LIFT)
SAND OR CLAYEY SAND=CEMENT STABILIZE
LIFT)
CLAY SOIL=LIME STABILIZE (36 LB/SY/6"
#8 (APPROX. STA. 114+00:
BORE #7 (APPROX. STA. 100+50) TO BORE
FLEX BASE TY-D GR 1-2
CONCENTRATION=REPLACE SUBGRADE WITH 12"
FIELD TEST >3000 PPM SULFATE
LIFT)
CLAY SOIL=LIME STABILIZE (36 LB/SY/6"
100+50):
STA 90+79.49 TO BORE #7 (APPROX. STA.
AND NO. 3 BARS @ 18" O.C.E.W
W/ 3000 PSI CONCRETE
4" REINF. CONCRETE SIDEWALK
AND NO. 3 BARS @ 18" O.C.E.W
SIDEWALK W/ 3000 PSI CONC
6" REINF. CONCRETE
AND NO. 3 BARS @ 18" O.C.E.W
SIDEWALK W/ 3000 PSI CONC
6" REINF. CONCRETE
AND NO. 3 BARS @ 18" O.C.E.W
W/ 3000 PSI CONCRETE
4" REINF. CONCRETE SIDEWALK
McKINNEY STREET CROWN TRANSITION
McKINNEY STREET TYPICAL SECTION - NO CROWN
N.T.S.STATION 107+50.00 TO 114+50.00
STATION 104+50.00 TO 107+50.00 N.T.S.
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
TYPICAL SECTIONS
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDT03.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDT03.dgn1:404:38:34 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837NTS
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
52
LC
6" GROUND
EXISTING
31.5' RT
PGL RT
25.5' LT
PGL LT
100' EX. R.O.W
TYP.
12"
TYP.
6"
LANE
11'
LANE
11'
TWO-WAY LEFT
12'
TURN LANE
(TYP.)
GUTTER
CURB &
STANDARD
SIDEWALK
TYP.
LANE
11'
LANE
11'
EXISTING GROUNDR.O.W.EX. R.O.W.EX. 57' B-B
2% MAX
1.5% TYP.
6:1 MAX
3:1 MAX
4:1 TYP.
2'
5.5'
6:1 MAX
1.5% TYP.
6:1 MAX
1.5% TYP.
3:1 MAX
4:1 TYP.
& GUTTER (TYP.)
STANDARD CURB
2% MAX
1.5% TYP.
FUTURE
6'
7'-9.5'
BIKE/PED PATH
12' FUTURE
VARIES*2.00%
LC
6"
GROUND
EXISTING
31.5' RT
PGL RT
25.5' LT
PGL LT
100' EX. R.O.W
TYP.
12"
TYP.
6"
LANE
11'
LANE
11'
TWO-WAY LEFT
12'
TURN LANE
(TYP.)
GUTTER
CURB &
STANDARD
SIDEWALK
TYP.
LANE
11'
LANE
11'
2.00%2.00%EXISTING GROUNDR.O.W.EX. R.O.W.EX. 57' B-B
6:1 MAX
3:1 MAX
4:1 TYP.
5.5'
6:1 MAX
1.5% TYP.
6:1 MAX
1.5% TYP.
3:1 MAX
4:1 TYP.
& GUTTER (TYP.)
STANDARD CURB
2% MAX
1.5% TYP.
FUTURE
6'
7'-9.5'
STATION 150+79.47 TO STATION 154+50.00
57' B-B TO EX.60' B-B
PAVEMENT SHIFT TRANSITION
McKINNEY STREET TYPICAL SECTION- TWO WAY LEFT TURN LANE
2% MAX
1.5% TYP.
2'
BIKE/PED PATH
12' FUTURE
3'
3'
5'
5'
3'-5.5'
3'-5.5'
3'
3'
BE USED FOR SUBGRADE PREP.
WILL ADVISE CONTRACTOR ON MATERIAL TO
SUBGRADE PREPARATION. CITY INSPECTOR
SOIL MATERIAL VIA TESTING PRIOR TO
OCTOBER 10, 2018. CONTRACTOR TO VERIFY
PUBLISHED BY TERRACON CONSULTANTS ON
GEOTECHNICAL REPORT NO. 94175295
SUBGRADE PREP. INSTRUCTIONS PER
McKINNEY STREET TYPICAL SECTION- TWO WAY LEFT TURN LANE N.T.S STATION 93+60.58 TO 104+50.00
3" ASPHALT SURFACE (TYPE C)
3" ASPHALT BASE (TYPE B)
6" ASPHALT BASE (TYPE B)
3" ASPHALT SURFACE (TYPE C)
3" ASPHALT BASE (TYPE B)
6" ASPHALT BASE (TYPE B)
12" STABILIZED SUBGRADE*
12" STABILIZED SUBGRADE**SUBGRADE NOTES
LIME STABILIZE (36 LB/SY/6" LIFT)
154+50:
BORE #9 (APPROX. STA 128+00) TO STA
(24 LB/SY/6" LIFT)
SAND OR CLAYEY SAND=CEMENT STABILIZE
LIFT)
CLAY SOIL=LIME STABILIZE (36 LB/SY/6"
#9 (APROX. STA. 128+00):
BORE #8 (APPROX. STA. 114+00) TO BORE
FLEX BASE TY-D GR 1-2
CONCENTRATION=REPLACE SUBGRADE WITH 12"
FIELD TEST >3000 PPM SULFATE
(24 LB/SY/6" LIFT)
SAND OR CLAYEY SAND=CEMENT STABILIZE
LIFT)
CLAY SOIL=LIME STABILIZE (36 LB/SY/6"
#8 (APPROX. STA. 114+00:
BORE #7 (APPROX. STA. 100+50) TO BORE
FLEX BASE TY-D GR 1-2
CONCENTRATION=REPLACE SUBGRADE WITH 12"
FIELD TEST >3000 PPM SULFATE
LIFT)
CLAY SOIL=LIME STABILIZE (36 LB/SY/6"
100+50):
STA 90+79.49 TO BORE #7 (APPROX. STA.
AND NO. 3 BARS @ 18" O.C.E.W
W/ 3000 PSI CONCRETE
4" REINF. CONCRETE SIDEWALK
AND NO. 3 BARS @ 18" O.C.E.W
SIDEWALK W/ 3000 PSI CONC
6" REINF. CONCRETE
AND NO. 3 BARS @ 18" O.C.E.W
SIDEWALK W/ 3000 PSI CONC
6" REINF. CONCRETE
AND NO. 3 BARS @ 18" O.C.E.W
W/ 3000 PSI CONCRETE
4" REINF. CONCRETE SIDEWALK
McKINNEY STREET CROWN TRANSITION
STATION 114+50.00 TO 119+00.00 N.T.S.
N.T.S. STATION 119+00.00 TO 150+79.47
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
TYPICAL SECTIONS
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDT04.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDT04.dgn1:304:38:36 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837NTS
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
TURN LANE
10'
TURN LANE
10'
TURN LANE
10'
CURB & GUTTER
STANDARD
3:1 MAX
4:1 TYP.
GROUND
EXISTING
SIDEWALK
EXISTING
GROUND
EXISTING
RYAN WAY TYPICAL SECTION
N.T.S
31' B-B
CONC. PAVEMENT
8" REINFORCED
EXISTING
EXISTING GRADE
53
CURB
EXISTING
TYP.
6"
TYP.
6"
5'
1.50%
W/ 8% LIME (48 LB/SY) (TYP.)
8" THICK STABILIZED SUBGRADE
W/ #4 BARS @ 18" O.C. EACH WAY
4000 PSI COMPRESSIVE STRENGTH
8" THICK REINF. CONC. PAVEMENT,
CROSS SLOPE
MATCH EX.
(SEE SHEET 85)
ANCHOR JOINT
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDM01.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDM01.dgn1:404:38:43 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
McKINNEY STREET
DEMOLITION PLAN
LEGEND
X
E. OF LOOP 288 TO W. OF GRISSOM ROAD
NOTES:
AL 2019
SEP
MISC. REMOVAL
TREE REMOVAL
PIPE OR CULVERT REMOVAL
CONCRETE SIDEWALK REMOVAL
CONCRETE DRIVEWAY REMOVAL
CONCRETE PAVEMENT REMOVAL
ASPHALT PAVEMENT REMOVAL
X
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
R.O.W. PREPARATION BID ITEM.
REMOVAL PAID FOR UNDER
CONTRACTOR REMOVING TREES. TREE
CITY APPROVAL REQUIRED PRIOR TO 5.
BE REPLACED.
APPROVAL. AREAS TO BE REMOVED MUST
TO BE REMOVED WITHOUT CITY
CONSTRUCTION. NO EXISTING SIDEWALK
STUDENT TRAFFIC THROUGHOUT
STREET SHALL BE MAINTAINED FOR
SIDEWALK ON NORTH SIDE OF McKINNEY 4.
PLANS FOR SIGN REMOVAL.
SEE PAVEMENT MARKING AND SIGNAGE 3.
ADDITIONAL REMOVAL ITEMS.
SEE WATER AND WASTEWATER SHEETS FOR 2.
TO CONSTRUCTION.
RELOCATED/ REMOVED BY OTHERS PRIOR
ALL UTILITIES IN CONFLICT TO BE 1.
PARKING AREA
PARKING AREA
S
S
S
LOT 24A
LOOP 288
7-ELEVEN INC
LOT 1
LOT 1
101 N LOOP 288
DENNIS J KOOP
LOT 1
3612 E McKINNEY STREET
McKINNEY BUILDING, LP
VOL. 1029, PG. 281
UTILITY EASEMENT
75' MAINTAINING PUBLIC
CAB. R, PG.
3
2EASEMENT2
0' PUBLI
C UTI
LI
TYVOL. 603, PG. 520
EASEMENT
16' PUBL
IC UT
IL
ITY
CAB. R, PG. 32
EASEMENT
20' PUBLIC UTILITY
CAB. F, PG. 336
ELEC. EASEMENT20' UTILITY &
CAB. F, PG. 336& ELEC.EASEMENT16' UTILITY
VOL. 603, PG. 5
20
EASEMENT
16' PUBL
IC UT
IL
ITY
101 S LOOP 288
INVESTMENT COMPANY
SEJ ASSET MANAGEMENT &
WV
WV WV
LT
LT
LT
LT
LT
3
0
" WW30" WW30" WW8" WW8" WW
8" W
8
" W8" W8" W20
" W
20
" W
8" W24" RCP
36" RCP
36" RCP
BOX CULVERTEx.
9'
x
5' BOX CULVERTEx.
9'
x
5' BOX CULVERTEx.
9'
x
5' BOX CULVERTEx.
5'
x
4' BOX CULVERTEx.
5'
x
4' BOX CULVERTEx.
5'x4' BOX CULVERTEx.
5'x3' BOX CULVERTEx.
6'
x
3'
24" RCP
24" RCP
24" RCP
24
" RCP
24" RCP 24" RCP
WV
20" W
88+00 90+00
91+00
87+00
1
0
0
7
2
+0
0
1
0
0
73+0
0
1
0
0
7
4
+0
0
89+00
54MATCHLINE STA 91+50McKINNEY STREETN LOOP 288S LOOP
2
8
8
PAVEMENT
REMOVE ASPHALT
24" RCP
REMOVE 254 LF
REMOVE INLET
BY OTHERS
TO BE RELOCATED
EX. POWER POLE
McKINNEY STREET
MEDIAN
REMOVE CONCRETE
SIDEWALK
CONCRETE
REMOVE
24" RCP
REMOVE 67 LF
SIGNAL BOX
TRAFFIC
RESET EX.
REMOVE &
FULL DEPTH
CONC. PVM'T.
REMOVE EX.
FULL DEPTH
CONC. PVM'T.
REMOVE EX.
EX. PED POLE
REMOVE & RESET
DRIVEWAY
REMOVE CONCRETE
VOL. 603, PG. 520
EASEMENT
16' PUBL
IC UT
IL
ITY
SIDEWALK
REMOVE CONCRETE
SIDEWALK
REMOVE CONCRETE
SIDEWALK
REMOVE CONCRETE
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDM02.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDM02.dgn1:404:38:45 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
McKINNEY STREET
DEMOLITION PLAN
LEGEND
X
E. OF LOOP 288 TO W. OF GRISSOM ROAD
NOTES:
AL 2019
SEP
MISC. REMOVAL
TREE REMOVAL
PIPE OR CULVERT REMOVAL
CONCRETE SIDEWALK REMOVAL
CONCRETE DRIVEWAY REMOVAL
CONCRETE PAVEMENT REMOVAL
ASPHALT PAVEMENT REMOVAL
X
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
R.O.W. PREPARATION BID ITEM.
REMOVAL PAID FOR UNDER
CONTRACTOR REMOVING TREES. TREE
CITY APPROVAL REQUIRED PRIOR TO 5.
BE REPLACED.
APPROVAL. AREAS TO BE REMOVED MUST
TO BE REMOVED WITHOUT CITY
CONSTRUCTION. NO EXISTING SIDEWALK
STUDENT TRAFFIC THROUGHOUT
STREET SHALL BE MAINTAINED FOR
SIDEWALK ON NORTH SIDE OF McKINNEY 4.
PLANS FOR SIGN REMOVAL.
SEE PAVEMENT MARKING AND SIGNAGE 3.
ADDITIONAL REMOVAL ITEMS.
SEE WATER AND WASTEWATER SHEETS FOR 2.
TO CONSTRUCTION.
RELOCATED/ REMOVED BY OTHERS PRIOR
ALL UTILITIES IN CONFLICT TO BE 1.
V
E
PARKING AREA
S
PARKING AREA
3730 E McKINNEY STREET
LISA FONG LEUNG
100 N LOOP 288
100 NORTH LOOP 288, LLC
101 S LOOP 288
DNB INVESTMENTS LTD
101 S LOOP 288
SEJ ASSET MANAGEMENT & INVESTMENT COMPANY
LOOP 288
7-ELEVEN INC
LOT 1
LOT 1
LOT 41LOT 1
LOT 24A
VOL. 603, PG. 520
EASEMENT16' PUBLIC UTILITY
CAB. R, PG. 32
EASEMENT
20' PUBLIC UTILITY
CAB. D, PG. 191
16' UTILITY EASEMENT
VOL. 603, PG. 520
EASEMENT
16' PUBLIC UTILITY
WV
WV
8" WW 8" WW 8" WW
8" W8" W 8" W
8" W
8" W
8" W 8" W
8" W
24" RCP 18" RCP
15" RCP
24" RCP 8" W
20" W
92+00 93+00 94+00 95+00
96+00
V
S
S S
E McKINNEY STREET
CCD-RLG DENTON I LP
3701 E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
3730 E McKINNEY STREET
LISA FONG LEUNG 191 DUCHESS DRIVE
JBJ/CALDER FUND VII JOINT VENTURE
LOT 1LOT 1
LOT 1
LOT 1
CAB. D, PG. 191
16' UTILITY EASEMENT
CAB. O, PG. 264
EASEMENT
15' PUBLIC UTILITY
CAB. O, PG. 264
10' UTILITY EASEMENT
CAB. O, PG. 264
10' UTILITY EASEMENT
CAB. XX, PG. XX
EASEMENT
PRIVATE DRAINAGE
CAB. X, PG. XX
EASEMENT
8' PUBLIC UTILITY
LOT 1
100 N LOOP 288
LLC
100 NORTH LOOP 288,
CAB. D, PG. 15
20' PUBLIC UTILITY EASEMENT
WV
WV
WV
8" WW
8" WW 8" WW
8" W
8" W 8" W 8" W
8" W
8" W 8" W 6" W(15" STEEL ENCASEMENT)8" WW(15" STEEL ENCASEMENT)8" WW8" W8
" W6" W
6" W8" WW 8" WW 8" WW(15" STEEL ENCASEMENT)8" WW(15" STEEL ENCASEMENT)8" WW6" W
T
97+00 98+00 99+00 100+00 101+00
XX X
X
X
55MATCHLINE STA 91+50McKINNEY STREET
MATCHLINE STA 96+50DRIVEDUCHESS McKINNEY STREET
MATCHLINE STA 96+50MATCHLINE STA 101+5015" RCP
REMOVE 44 LF
18" RCP
REMOVE 31 LF24" RCP
REMOVE 29 LF
24" RCP
REMOVE 26 LF
HEADWALL
REMOVE
PAVEMENT
REMOVE ASPHALT
HEADWALL
REMOVE
HEADWALL
REMOVE
DRIVEWAY
REMOVE CONCRETE
DRIVEWAY
REMOVE CONCRETE
DRIVEWAY
REMOVE CONCRETE
PAVEMENT
REMOVE ASPHALT
DRIVEWAY
REMOVE CONCRETE
HEADWALL
REMOVE
BY OTHERS
TO BE RELOCATED
EX. POWER POLE
DRIVEWAY
REMOVE GRAVEL
DRIVEWAY
REMOVE ASPHALT
SIDEWALK
REMOVE CONCRETE
SIDEWALK
REMOVE CONCRETE
(TYP.)
REMOVE TREE
(TYP.)
REMOVE TREE
SIDEWALK
REMOVE CONCRETE
SIDEWALK
REMOVE CONCRETE SIDEWALK
REMOVE CONCRETE
SIDEWALK
REMOVE CONCRETE
SIDEWALK
REMOVE CONCRETE
SIDEWALK
REMOVE CONCRETE
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDM03.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDM03.dgn1:404:38:49 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
McKINNEY STREET
DEMOLITION PLAN
LEGEND
X
E. OF LOOP 288 TO W. OF GRISSOM ROAD
NOTES:
AL 2019
SEP
MISC. REMOVAL
TREE REMOVAL
PIPE OR CULVERT REMOVAL
CONCRETE SIDEWALK REMOVAL
CONCRETE DRIVEWAY REMOVAL
CONCRETE PAVEMENT REMOVAL
ASPHALT PAVEMENT REMOVAL
X
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
R.O.W. PREPARATION BID ITEM.
REMOVAL PAID FOR UNDER
CONTRACTOR REMOVING TREES. TREE
CITY APPROVAL REQUIRED PRIOR TO 5.
BE REPLACED.
APPROVAL. AREAS TO BE REMOVED MUST
TO BE REMOVED WITHOUT CITY
CONSTRUCTION. NO EXISTING SIDEWALK
STUDENT TRAFFIC THROUGHOUT
STREET SHALL BE MAINTAINED FOR
SIDEWALK ON NORTH SIDE OF McKINNEY 4.
PLANS FOR SIGN REMOVAL.
SEE PAVEMENT MARKING AND SIGNAGE 3.
ADDITIONAL REMOVAL ITEMS.
SEE WATER AND WASTEWATER SHEETS FOR 2.
TO CONSTRUCTION.
RELOCATED/ REMOVED BY OTHERS PRIOR
ALL UTILITIES IN CONFLICT TO BE 1.
PARKING AREA
DBL. 10" HACKBERRY
18" ELM 6" TREE
TRI 4" TREE
QUAD 6" ELM
DBL. 8" HACKBERRY 6" ELM DBL. 6"/12" HACKBERRY DBL. 6" HACKBERRY DBL. 8" HACKBERRY
4" ELM
6" ELM
DBL. 12" HACKBERRY
DBL. 6" ELM
10" TREE
S
191 DUCHESS DRIVE
JBJ/CALDER FUND VII JOINT VENTURE
E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
STREET
3910 E McKINNEY SCOTTIE ADAMS
LOT 1
LOT 27 LOT 29
LOT 1
CAB. D, PG. 15
20' PUBLIC UTILITY EASEMENT
CAB. O, PG. 264
10' UTILITY EASEMENT
CAB. O, PG. 264
10' UTILITY EASEMENT
CAB. B, PG. 71
25' UTILITY EASEMENT
CAB. B, PG. 7116' UTILITY EASEMENT
8" W
8" W
8" W
6" W
6" W
6" W6" W
6" W
8" WW
15" RCP
102+00 103+00 104+00 105+00
106+00
X
X
X X XXX
XX
X
V
PARKING AREA PARKING AREA PARKING AREA
CONCRETE
PARKING AREA
PARKING AREA
PARKING AREA
24" HACKBERRYDBL. 12" TREE
24" TREETRI 6" TREE
15" HACKBERRY10" CEDAR
DBL. 10" TREE
DBL. 12" HACKBERRY
S
3912 E McKINNEY STREET
DUNCAN STREET COMMERCIAL LLC
3910 E McKINNEY STREET
SCOTTIE ADAMS
E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
3801 E McKINNEY STREET
ANGEL & GRISELDA ENRIQUEZ
3919/3921 E McKINNEY STREET
NSA PROPERTY HOLDINGS, LLC
3916 E McKINNEY STREET
EDWARD D & SHARYL K DIELEMAN
3918-3920 E McKINNEY STREET
LESLIE A & MICHAEL L ORINGDERFF
LOT 38
LOT 4LOT 3LOT 2LOT 1
LOT 29 LOT 1R
CAB. B, PG. 71
25' UTILITY EASEMENTCAB. B, PG. 71
16' UTILITY EASEMENT
CAB. Y, PG. 289
20' UTILITY EASEMENT
WV
WVWVWV6" W
6" W8" WW
8" WW 8" WW
8" W
8" W
8" W
6" W6" W
6" W
8" WW
8" WW
15" RCP
24" RCP
18" RCP
15" RCP
18" RCP 18" RCP
18" RCP
8" WW
106+00
107+00 108+00 109+00 110+00
X
XXXXXXX XXXXXXXXXXXXXXXXXXX
X
56MATCHLINE STA 106+00MATCHLINE STA 101+50McKINNEY STREET
MATCHLINE STA 106+00MATCHLINE STA 110+50McKINNEY STREET
PAVEMENT
REMOVE ASPHALT
15" RCP
REMOVE 31 LF
24" RCP
REMOVE 16 LF
15" RCP
REMOVE 16 LF
15" RCP
REMOVE 29 LF
18" RCP
REMOVE 47 LF
18" RCP
REMOVE 37 LF
18" RCP
REMOVE 24 LF
18" RCP
REMOVE 31 LF
CONCRETE
REMOVE
CONCRETE
REMOVE
WALL
RETAINING
REMOVE
WALL
RETAINING
REMOVE
BY OTHERS
TO BE RELOCATED
EX. POWER POLE
PAVEMENT
GRAVEL
REMOVE
OTHERS
RELOCATED BY
BE REMOVED AND
IRON GATE TO
BY OTHERS
BE REMOVED
IRON GATE TO
DRIVEWAY
REMOVE ASPHALT
DRIVEWAY
REMOVE CONCRETE
DRIVEWAY (TYP.)
REMOVE ASPAHLT
DRIVEWAY
REMOVE CONCRETE
PAVEMENT
REMOVE CONCRETE
DRIVEWAY
REMOVE GRAVEL
2 EX. MAILBOXES
REMOVE AND RESET
SIDEWALK
REMOVE CONCRETE
PAVEMENT
REMOVE ASPHALT
DONE BY OTHERS TO STA 119+50
CONTRACT, BEGIN WORK TO BE
STA 106+00 END WORK THIS
(TYP.)
REMOVE TREE
REMOVE TREE (TYP.)
REFERENCE ONLY
(TYP.)
REMOVE TREE
SIDEWALK
REMOVE CONCRETE
SIDEWALK (TYP.)
REMOVE CONCRETE
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDM04.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDM04.dgn1:404:38:52 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
McKINNEY STREET
DEMOLITION PLAN
LEGEND
X
E. OF LOOP 288 TO W. OF GRISSOM ROAD
NOTES:
AL 2019
SEP
MISC. REMOVAL
TREE REMOVAL
PIPE OR CULVERT REMOVAL
CONCRETE SIDEWALK REMOVAL
CONCRETE DRIVEWAY REMOVAL
CONCRETE PAVEMENT REMOVAL
ASPHALT PAVEMENT REMOVAL
X
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
R.O.W. PREPARATION BID ITEM.
REMOVAL PAID FOR UNDER
CONTRACTOR REMOVING TREES. TREE
CITY APPROVAL REQUIRED PRIOR TO 5.
BE REPLACED.
APPROVAL. AREAS TO BE REMOVED MUST
TO BE REMOVED WITHOUT CITY
CONSTRUCTION. NO EXISTING SIDEWALK
STUDENT TRAFFIC THROUGHOUT
STREET SHALL BE MAINTAINED FOR
SIDEWALK ON NORTH SIDE OF McKINNEY 4.
PLANS FOR SIGN REMOVAL.
SEE PAVEMENT MARKING AND SIGNAGE 3.
ADDITIONAL REMOVAL ITEMS.
SEE WATER AND WASTEWATER SHEETS FOR 2.
TO CONSTRUCTION.
RELOCATED/ REMOVED BY OTHERS PRIOR
ALL UTILITIES IN CONFLICT TO BE 1.
PARKING AREA
CONCRETE
CONCRETE
E
E
PARKING AREA
S
S
S
D
D
S
S
STREET
4001 E McKINNEY
CITY OF DENTON
E McKINNEY STREET
CITY OF DENTON
3922 E McKINNEY STREET
GOEL VENTURES ONE, LLC
3918-3920 E McKINNEY STREET
LESLIE A & MICHAEL L ORINGDERFF
3923 E McKINNEY STREET
DENTON 3919 McKINNEY, LLC
LOT 153
LOT 3LOT 1R
LOT 151 (PT)LOT 5R1
LOT 152
CAB. B, PG. 71
25' UTILITY EASEMENT
CAB. Y, PG. 289
20' UTILITY EASEMENT
CAB. B, PG. 147
16' UTILITY EASEMENT
VOL. 5039, PG. 01970
DRAINAGE EASEMENT
20' PERMANENT
STRIP)
E McKINNEY STREET (200'
VENTURES, LP
BCI REAL ESTATE
WV
wv1719590.20
WV
wv no lid5248583.02
Ex. 8" Water
Ex. 8" Water
Ex. 8" Wat
er
Ex. 16" Water
8" WW
8" W
6" W
12" W
12" W12" W6" W 12" W 12" W 20" W16" W
20" W20"
W20" W
8" WW 10" WW8" WW8" WW10" WW8" W20" W 12" W
12" W8" W
8" W
8" WW 8" WW8" WW
2-18" RCP
27" RCP
BOX CULVERT6'x4'BOX CULVERT6'x4'BOX CULVERT6'x4'B
O
X
C
U
L
V
E
R
T
6'x4'
8" WW
(ABANDONED)10" WW(AB
A
NDON
E
D)
1
0" WW8" WW
10'x4' RCBC111+00 112+00 113+00 114+00 115+00
222+00223+00PARKING AREA
E McKINNEY STREET (200' STRIP)
BCI REAL ESTATE VENTURES, LP BAYLOR UNIVERSITY
4301 E McKINNEY STREET
CITY OF DENTON
4393 E McKINNEY STREET
KENNETH L & GLADYS F STOUT
LOT 151 (PT)LOT 151 (PT)
LOT 159 LOT 161LOT 154
STREET
4515 E McKINNEY
GLADYS F STOUT
KENNETH L &
STREET
4515 E McKINNEY
GLADYS F STOUT
KENNETH L &
WV16" W 16" W 16" W
8" W 8" W
8" WW 8" WW
15" CMP 15" CMP
116+00 117+00 118+00 119+00
57MATCHLINE STA 110+50McKINNEY STREET
MATCHLINE STA 115+50MATCHLINE STA 115+50ROADN MAYHI
LL ROADS MAYHI
LL
McKINNEY STREET
27" RCP
REMOVE 31 LF
18" RCP
REMOVE 304 LF
HEADWALL
REMOVE
HEADWALL
REMOVE 15" CMP
REMOVE 32 LF
15" CMP
REMOVE 32 LF
HEADWALL
REMOVE
CONCRETE
REMOVE
LOT 5R1
MATCHLINE STA 119+00BAYLOR UNIVERSITY
LOT 151 (PT)
PAVEMENT
REMOVE CONCRETE
DRIVEWAY
CONCRETE
REMOVE
DRIVEWAY
ASPHALT
REMOVE
PAVEMENT
REMOVE ASPHALT
PAVEMENT
REMOVE ASPHALT
10'x4' RCB CULVERT
REMOVE 45 LF
DRIVEWAY (TYP.)
REMOVE GRAVEL
END TREATMENT
REMOVE SAFETY
MAILBOX
REMOVE AND RESET
65
DEMOLITION PLAN
MAYHILL ROAD
SEE SH. FOR
REFERENCE ONLY
McKINNEY STREET
SIDEWALK
REMOVE CONCRETE
SIDEWALK
REMOVE CONCRETE
SIDEWALK
REMOVE CONCRETE
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDM05.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDM05.dgn1:404:38:56 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
McKINNEY STREET
DEMOLITION PLAN
LEGEND
X
E. OF LOOP 288 TO W. OF GRISSOM ROAD
NOTES:
AL 2019
SEP
MISC. REMOVAL
TREE REMOVAL
PIPE OR CULVERT REMOVAL
CONCRETE SIDEWALK REMOVAL
CONCRETE DRIVEWAY REMOVAL
CONCRETE PAVEMENT REMOVAL
ASPHALT PAVEMENT REMOVAL
X
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
R.O.W. PREPARATION BID ITEM.
REMOVAL PAID FOR UNDER
CONTRACTOR REMOVING TREES. TREE
CITY APPROVAL REQUIRED PRIOR TO 5.
BE REPLACED.
APPROVAL. AREAS TO BE REMOVED MUST
TO BE REMOVED WITHOUT CITY
CONSTRUCTION. NO EXISTING SIDEWALK
STUDENT TRAFFIC THROUGHOUT
STREET SHALL BE MAINTAINED FOR
SIDEWALK ON NORTH SIDE OF McKINNEY 4.
PLANS FOR SIGN REMOVAL.
SEE PAVEMENT MARKING AND SIGNAGE 3.
ADDITIONAL REMOVAL ITEMS.
SEE WATER AND WASTEWATER SHEETS FOR 2.
TO CONSTRUCTION.
RELOCATED/ REMOVED BY OTHERS PRIOR
ALL UTILITIES IN CONFLICT TO BE 1.
PARKING AREA
PBX
585.19
5/8" IRS W/RANDOM
34
DOC # 99-R0026679
EASEMENT
20' PUBLIC UTILITY
BAYLOR UNIVERSITY
4515 E McKINNEY STREET
KENNETH L & GLADYS F STOUT
LOT 151 (PT)
LOT 161 LOT 162, 163, 164 (OLD DCAD 1P, 1P2, 1R), AC
4663 E McKINNEY STREET
MEMORIAL BAPTIST CHURCH OF DENTON
FM
16" W
16" W
8" W
8" WW 8" WW
15" CMP 15" CMP
16" W
119+00 120+00 121+00
X
VOL. 5039, PG. 01056
EASEMENT
8' PUBLIC UTILITY
VOL. 5039, PG. 01056
EASEMENTCONSTRUCTION
20' TEMPORARY
VOL. 5039, PG. 01056
EASEMENT
20' PUBLIC UTILITY
BAYLOR UNIVERSITY
4663 E McKINNEY STREETMEMORIAL BAPTIST CHURCH OF DENTON 4673 E McKINNEY STREET
MEMORIAL BAPTIST CHURCH OF DENTON
4683 E McKINNEY STREET
SAYR RESOURCES INC
LOT 151 (PT)
LOT 162, 163, 164 (OLD DCAD 1P, 1P2, 1R), AC
LOT 166 LOT 167
BCI REAL ESTATE VENTURES,LP
LOT 151 (PT)
122+00 123+00 124+00 125+00 126+00
PARKING AREA
PBX
8" HACKBERRY
DBL. 15"/24" PECAN24" PECAN
27" PECANDBL. 18" ELM
15" PECAN
TRI 12" PECAN
30" PECAN
DBL. 8" TREEDBL. 8"/15" TREE
S
WV
WV 16" W 16" W
8" W 8" W
8" WW 8" WW 8" WW
18" CMP 15" RCP 15" RCP
X
XX
McKINNEY STREET
MATCHLINE STA 121+50
F.L. XXXT.C. XXXCL 10' REC. INLETPAV STA 113+99.92, 39.49' RT
58MATCHLINE STA 121+50MATCHLINE STA 126+00 PAVEMENT
REMOVE ASPHALT
BY OTHERS
TO BE RELOCATED
EX. POWER POLE
15" CMP
REMOVE 41 LF
15" CMP
REMOVE 20 LF
BY OTHERS
TO BE RELOCATED
EX. POWER POLE
18" CMP
REMOVE 40 LF
PAVEMENT
REMOVE ASPHALT
15" RCP
REMOVE 16 LF
15" RCP
REMOVE 16 LF
McKINNEY STREETMATCHLINE STA 119+00 PAVEMENT
REMOVE ASPHALT
DRIVEWAY (TYP.)
REMOVE ASPHALT
DRIVEWAY (TYP.)
REMOVE ASPHALT
REMOVE TREE
END WORK TO BE DONE BY OTHERS
BEGIN WORK THIS CONTRACT
STA 119+50
(TYP.)
REMOVE TREES
MAILBOX
REMOVE AND RESET
SIDEWALK
REMOVE CONCRETE
SIDEWALK
REMOVE CONCRETE
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDM06.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDM06.dgn1:404:38:58 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
McKINNEY STREET
DEMOLITION PLAN
LEGEND
X
E. OF LOOP 288 TO W. OF GRISSOM ROAD
NOTES:
AL 2019
SEP
MISC. REMOVAL
TREE REMOVAL
PIPE OR CULVERT REMOVAL
CONCRETE SIDEWALK REMOVAL
CONCRETE DRIVEWAY REMOVAL
CONCRETE PAVEMENT REMOVAL
ASPHALT PAVEMENT REMOVAL
X
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
R.O.W. PREPARATION BID ITEM.
REMOVAL PAID FOR UNDER
CONTRACTOR REMOVING TREES. TREE
CITY APPROVAL REQUIRED PRIOR TO 5.
BE REPLACED.
APPROVAL. AREAS TO BE REMOVED MUST
TO BE REMOVED WITHOUT CITY
CONSTRUCTION. NO EXISTING SIDEWALK
STUDENT TRAFFIC THROUGHOUT
STREET SHALL BE MAINTAINED FOR
SIDEWALK ON NORTH SIDE OF McKINNEY 4.
PLANS FOR SIGN REMOVAL.
SEE PAVEMENT MARKING AND SIGNAGE 3.
ADDITIONAL REMOVAL ITEMS.
SEE WATER AND WASTEWATER SHEETS FOR 2.
TO CONSTRUCTION.
RELOCATED/ REMOVED BY OTHERS PRIOR
ALL UTILITIES IN CONFLICT TO BE 1.
PBX
36" TREE
36" PECAN
2" TREE
36" PECAN
2" TREE
48" PECAN
DBL. 4"/15" HACKBERRY
6" HACKBERRY
21" CEDARDBL. 15"/24" PECAN
S
586.97
5/8" IRS W/RANDOM
35
BCI REAL ESTATE VENTURES,LP
5001 E McKINNEY STREET
BARBARA McDONALD COBB
5043 E McKINNEY STREET
CHELA DARLINE McDONALD
LOT 151 (PT)
LOT 168 LOT 169
VOL. 5039, PG. 01056
EASEMENTCONSTRUCTION
20' TEMPORARY
VOL. 5039, PG. 01056
EASEMENT
20' PUBLIC UTILITY
VOL. 5039, PG. 01056
EASEMENT
8' PUBLIC UTILITY DOC
#
9
9
-R0
07730
9UTILITY EASEMENT
2
0' PUBLI
C
126+00 127+00 128+00 129+00 130+00
XX
X X X
BCI REAL ESTATE VENTURES,LP
5101 E McKINNEY STREET
DENTON ISD
5090 E McKINNEY STREET
EDIBERTO A RODRIGUEZ E McKINNEY STREET
KIM Y PHAM
LOT 151 (PT)
LOT 1R4
LOT 150 LOT 1
CAB. H, PG. 62
20' UTILITY EASEMENT
CAB. E, PG. 330
4' SIDEWALK EASEMENT
130+00 131+00 132+00 133+00 134+00
135+00
CONCRETE
PBX
E
X
FM
16" W 16" W
8" WW 8"
WW6" W 6
" W8" W
15" RCP
15" RCP
21" RCP 21" RCP 21" RCP
8" WW 8"
WWWV
WV
WVFM
16" W 16" W
16" W
8" W
8" W 8" W10" W10" W
10" W
24" RCP
27" RCP
1
5"
R
C
P
24"
R
C
P
27" RCP 27" RCP
2-48" RCP24"
R
CPRCBCEX.9'X6'MATCHLINE STA 130+00MATCHLINE STA 130+00MATCHLINE STA 135+00MATCHLINE STA 126+00McKINNEY STREET
15" RCP
REMOVE 16 LF
BY OTHERS
TO BE RELOCATED
EX. POWER POLE
15" RCP
REMOVE 18 LF
REMOVE INLET
REMOVE INLET
REMOVE INLET
REMOVE INLET
BY OTHERS
TO BE RELOCATED
EX. POWER POLE
PAVEMENT
REMOVE ASPHALT
21" RCP
REMOVE 48 LF
21" RCP
REMOVE 88 LF
21" RCP
REMOVE 54 LF
24" RCP
REMOVE 91 LF
PAVEMENT
REMOVE CONCRETE
PAVEMENT
REMOVE ASPHALT
27" RCP
REMOVE 218 LF
BY OTHERS
TO BE RELOCATED
EX. POWER POLE
HEADWALL
REMOVE
9'X6' RCB CULVERT
REMOVE 66 LF
2-48" RCP CULVERT
REMOVE 36 LF
HEADWALL
REMOVE
INLET
REMOVE
GUARDRAIL
REMOVE
GUARDRAIL
REMOVE
REMOVE INLET
24" RCP
REMOVE 53 LF
REMOVE HEADWALL
BY OTHERS
TO BE RELOCATED
EX. POWER POLE
McKINNEY STREETRYAN WAY59ROADN CARPENTER49 LF STEEL POST FENCE
REMOVE AND RESET
DRIVEWAY (TYP.)
REMOVE ASPHALT
DRIVEWAY
REMOVE ASPHALT
BY OTHERS
TO BE RELOCATED
EX. POWER POLE
66
DEMOLITION PLAN
RYAN WAY
SEE SH. FOR
REMOVE INLET REMOVE INLET
24" RCP
REMOVE 53 LF
15" RCP
43 LF
REMOVE
REMOVE TREES (TYP.)
DRIVEWAY
REMOVE GRAVEL
TREE
REMOVE
RE-LOCATED BY OTHERS
EX. POWER POLE TO BE
MAILBOX
RESET EX.
REMOVE AND
SIDEWALK
REMOVE CONCRETE
SIDEWALK
REMOVE CONCRETE
SIDEWALK
REMOVE CONCRETE
SIDEWALK
REMOVE CONCRETE
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDM07.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDM07.dgn1:404:39:01 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
McKINNEY STREET
DEMOLITION PLAN
LEGEND
X
E. OF LOOP 288 TO W. OF GRISSOM ROAD
NOTES:
AL 2019
SEP
MISC. REMOVAL
TREE REMOVAL
PIPE OR CULVERT REMOVAL
CONCRETE SIDEWALK REMOVAL
CONCRETE DRIVEWAY REMOVAL
CONCRETE PAVEMENT REMOVAL
ASPHALT PAVEMENT REMOVAL
X
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
R.O.W. PREPARATION BID ITEM.
REMOVAL PAID FOR UNDER
CONTRACTOR REMOVING TREES. TREE
CITY APPROVAL REQUIRED PRIOR TO 5.
BE REPLACED.
APPROVAL. AREAS TO BE REMOVED MUST
TO BE REMOVED WITHOUT CITY
CONSTRUCTION. NO EXISTING SIDEWALK
STUDENT TRAFFIC THROUGHOUT
STREET SHALL BE MAINTAINED FOR
SIDEWALK ON NORTH SIDE OF McKINNEY 4.
PLANS FOR SIGN REMOVAL.
SEE PAVEMENT MARKING AND SIGNAGE 3.
ADDITIONAL REMOVAL ITEMS.
SEE WATER AND WASTEWATER SHEETS FOR 2.
TO CONSTRUCTION.
RELOCATED/ REMOVED BY OTHERS PRIOR
ALL UTILITIES IN CONFLICT TO BE 1.
587.025/8" IRS W/RANDOM36
5101 E McKINNEY STREET
DENTON ISD
LOT 1R4
E McKINNEY STREET
KIM Y PHAM
LOT 1
CAB. H, PG. 6220' UTILITY EASEMENT
CAB. E, PG. 330
4' SIDEWALK EASEMENT
135+00 136+00 137+00 138+00
139+00
5101 E McKINNEY STREET
DENTON ISD
E McKINNEY STREET
KIM Y PHAM E McKINNEY STREET
KIM Y PHAM
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
LOT 1R4
LOT 1
LOT 1, BLOCK A
LOT 1, BLOCK B
CAB. H, PG. 62
20' UTILITY EASEMENT
CAB. H, PG. 62
16' UTILITY EASEMENT
CAB. E, PG. 60
16' UTILITY EASEMENTCAB.
H,
P
G.
6
2
1
6' UTI
LI
T
Y
E
AS
E
ME
N
T
CAB. E, PG. 330
EASEMENT
4' SIDEWALK
CAB. E, PG. 330
4' SIDEWALK EASEMENT
139+00 140+00 141+00 142+00 143+00
V
E
ES
592.87
5/8" IRS W/RANDOM
37
WV
10" W 10" W
16" W
16" W
16" W
24" RCP
WV WV
WVWV
WV
WV
WVWV
FM
10" W 10" W
16" W 16" W 16" W 16" W16" W8" W10" WW
10" WW10"WW16" W
(F
O
R
C
E MAI
N)
8" WW8" WW8" WMATCHLINE STA 143+50MATCHLINE STA 139+00MATCHLINE STA 135+00MATCHLINE STA 139+0024" RCP
REMOVE 65 LF
DRIVEWAY
REMOVE CONCRETE
BY OTHERS
TO BE RELOCATED
EX. POWER POLE
McKINNEY STREET
BY OTHERS
TO BE RELOCATED
EX. POWER POLE
BY OTHERS
TO BE RELOCATED
EX. POWER POLE
BY OTHERS
TO BE RELOCATED
EX. POWER POLE
DRIVEWAY
REMOVE ASPHALT
McKINNEY STREET
GLENNGARY WAY60
PAVEMENT
REMOVE ASPHALT
PAVEMENT
REMOVE ASPHALT
SIDEWALK
REMOVE CONCRETE
SIDEWALK
REMOVE CONCRETE
SIDEWALK
REMOVE CONCRETE
SIDEWALK
REMOVE CONCRETE
SIDEWALK
REMOVE CONCRETE
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDM08.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDM08.dgn1:404:39:04 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
McKINNEY STREET
DEMOLITION PLAN
LEGEND
X
E. OF LOOP 288 TO W. OF GRISSOM ROAD
NOTES:
AL 2019
SEP
MISC. REMOVAL
TREE REMOVAL
PIPE OR CULVERT REMOVAL
CONCRETE SIDEWALK REMOVAL
CONCRETE DRIVEWAY REMOVAL
CONCRETE PAVEMENT REMOVAL
ASPHALT PAVEMENT REMOVAL
X
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
R.O.W. PREPARATION BID ITEM.
REMOVAL PAID FOR UNDER
CONTRACTOR REMOVING TREES. TREE
CITY APPROVAL REQUIRED PRIOR TO 5.
BE REPLACED.
APPROVAL. AREAS TO BE REMOVED MUST
TO BE REMOVED WITHOUT CITY
CONSTRUCTION. NO EXISTING SIDEWALK
STUDENT TRAFFIC THROUGHOUT
STREET SHALL BE MAINTAINED FOR
SIDEWALK ON NORTH SIDE OF McKINNEY 4.
PLANS FOR SIGN REMOVAL.
SEE PAVEMENT MARKING AND SIGNAGE 3.
ADDITIONAL REMOVAL ITEMS.
SEE WATER AND WASTEWATER SHEETS FOR 2.
TO CONSTRUCTION.
RELOCATED/ REMOVED BY OTHERS PRIOR
ALL UTILITIES IN CONFLICT TO BE 1.
S
E McKINNEY STREET
KIM Y PHAM
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
E McKINNEY STREET
ATMOS ENERGY CORP
LOT 1
LOT 147BLOT 1, BLOCK B
CAB. E, PG. 60
16' UTILITY EASEMENT
CAB. E, PG. 330
EASEMENT
4' SIDEWALK
144+00 145+00 146+00 147+00 148+00
E McKINNEY STREET
ATMOS ENERGY CORP
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
LOT 147B
LOT 1 LOT 1
CAB. E, PG. 60
16' UTILITY EASEMENT
CAB. E, PG. 60
16' UTILITY EASEMENT
148+00 149+00 150+00 151+00 152+00
CONCRETE E
S S
S
582.48
X CUT SET
38
FM
T
16" W 16" W 16" W
8" WW 8" WW 8" WW
18" RCP
8" WW6" WW16" W 16" W 16" W
8" WW 8" WW 8" WW 8" WW6" WWWV
WV
FMFM
16" W
16" W
8" WW 8" WW
12" WW12" W W8" WW 8" WW
16" W
18" RCP BOX CULVERT4.35'x4'3
-
3
6
" CMP
8" WW 6" WW8" WW
16" W16" W16" W
8" WW
8" WW12" WW12" W W8" WW8" WW
8" WW 6" WW8" WWRCBEX.3-6'x3'8" WWMATCHLINE STA 143+50MATCHLINE STA 148+00MATCHLINE STA 152+50MATCHLINE STA 148+00BY OTHERS
TO BE RELOCATED
EX. POWER POLE
REMOVE HEADWALL
18" RCP
REMOVE 29 LF
DRIVEWAY
REMOVE GRAVEL
BY OTHERS
TO BE RELOCATED
EX. POWER POLE
McKINNEY STREET
McKINNEY STREETS FORK DRIVEBY OTHERS
TO BE RELOCATED
EX. POWER POLE
18" RCP
REMOVE 91 LF
PAVEMENT
REMOVE CONCRETE
REMOVE HEADWALL
6'x3' BOX CULVERT
REMOVE 140 LF
REMOVE HEADWALL
REMOVE HEADWALL
61
PAVEMENT
REMOVE ASPHALT
PAVEMENT
REMOVE ASPHALT
12" WWBY OTHERS
TO BE RELOCATED
EX. POWER POLE
SIDEWALK
REMOVE CONCRETE
SIDEWALK
REMOVE CONCRETE
SIDEWALK
REMOVE CONCRETE
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDM09.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDM09.dgn1:404:39:07 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
McKINNEY STREET
DEMOLITION PLAN
LEGEND
X
E. OF LOOP 288 TO W. OF GRISSOM ROAD
NOTES:
AL 2019
SEP
MISC. REMOVAL
TREE REMOVAL
PIPE OR CULVERT REMOVAL
CONCRETE SIDEWALK REMOVAL
CONCRETE DRIVEWAY REMOVAL
CONCRETE PAVEMENT REMOVAL
ASPHALT PAVEMENT REMOVAL
X
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
R.O.W. PREPARATION BID ITEM.
REMOVAL PAID FOR UNDER
CONTRACTOR REMOVING TREES. TREE
CITY APPROVAL REQUIRED PRIOR TO 5.
BE REPLACED.
APPROVAL. AREAS TO BE REMOVED MUST
TO BE REMOVED WITHOUT CITY
CONSTRUCTION. NO EXISTING SIDEWALK
STUDENT TRAFFIC THROUGHOUT
STREET SHALL BE MAINTAINED FOR
SIDEWALK ON NORTH SIDE OF McKINNEY 4.
PLANS FOR SIGN REMOVAL.
SEE PAVEMENT MARKING AND SIGNAGE 3.
ADDITIONAL REMOVAL ITEMS.
SEE WATER AND WASTEWATER SHEETS FOR 2.
TO CONSTRUCTION.
RELOCATED/ REMOVED BY OTHERS PRIOR
ALL UTILITIES IN CONFLICT TO BE 1.
S
E McKINNEY STREET
ATMOS ENERGY CORP
LOT 147A
E McKINNEY STREET
ATMOS ENERGY CORP
LOT 147B
LOT 1
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
CAB. E, PG. 60
16' UTILITY EASEMENT
153+00
154+00 155+00 156+00
157+00
E McKINNEY STREET
ATMOS ENERGY CORP
E McKINNEY STREET & TRINITY ROAD
THE WOODLANDS ON McKINNEY STREET LLC
K
O
R
N
U
P
A
U
L
& WE
N TS
AI
LOT 147A
LOT 143, 144L
O
T 108
LOT 1
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
CAB. E, PG. 60
16' UTILITY EASEMENT
V
OL. 990, P
G.640
15'
UTILIT
Y E
AS
E
ME
N
T
157+00 158+00 159+00 160+00 161+00
585.97PK NAIL SET39
DD
FM
8" WW
16" W
16" W
8" WW
8" WW
16" W
16" W
8" WW
8" WW
8" WW
3'x2' RCB
3'x2' RCB
16" W 16" W 16" W12" W12" W8" WW
16" W 16" W 16" W12" W12" W8" WW
24" RCP 24" RCP 18"18" RCP18"18" RCP24" RCP
D RCP18" DMATCHLINE STA 152+50MATCHLINE STA 157+00MATCHLINE STA 161+50MATCHLINE STA 157+00BY OTHERS
TO BE RELOCATED
EX. POWER POLE
REMOVE HEADWALL 3'X2' RCB
REMOVE 75 LF
PAVEMENT
REMOVE ASPHALT
McKINNEY STREET
McKINNEY STREET
62
METAL BEAM GUARD FENCE
REMOVE 100 LF
TO BE REMOVED
WITHIN R.O.W. LIMITS
EX. POST AND WIRE FENCE
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDM10.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDM10.dgn1:404:39:09 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
McKINNEY STREET
DEMOLITION PLAN
LEGEND
X
E. OF LOOP 288 TO W. OF GRISSOM ROAD
NOTES:
AL 2019
SEP
MISC. REMOVAL
TREE REMOVAL
PIPE OR CULVERT REMOVAL
CONCRETE SIDEWALK REMOVAL
CONCRETE DRIVEWAY REMOVAL
CONCRETE PAVEMENT REMOVAL
ASPHALT PAVEMENT REMOVAL
X
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
R.O.W. PREPARATION BID ITEM.
REMOVAL PAID FOR UNDER
CONTRACTOR REMOVING TREES. TREE
CITY APPROVAL REQUIRED PRIOR TO 5.
BE REPLACED.
APPROVAL. AREAS TO BE REMOVED MUST
TO BE REMOVED WITHOUT CITY
CONSTRUCTION. NO EXISTING SIDEWALK
STUDENT TRAFFIC THROUGHOUT
STREET SHALL BE MAINTAINED FOR
SIDEWALK ON NORTH SIDE OF McKINNEY 4.
PLANS FOR SIGN REMOVAL.
SEE PAVEMENT MARKING AND SIGNAGE 3.
ADDITIONAL REMOVAL ITEMS.
SEE WATER AND WASTEWATER SHEETS FOR 2.
TO CONSTRUCTION.
RELOCATED/ REMOVED BY OTHERS PRIOR
ALL UTILITIES IN CONFLICT TO BE 1.
D
E McKINNEY STREET & TRINITY ROAD
THE WOODLANDS ON McKINNEY STREET LLC
E McKINNEY STREET
ATMOS ENERGY CORP
LOT 143, 144
LOT 147A LOT 146
E McKINNEY STREET
ATMOS ENERGY CORP
162+00 163+00 164+00 165+00 166+00
X X
E McKINNEY STREET & TRINITY ROAD
THE WOODLANDS ON McKINNEY STREET LLC
E McKINNEY STREET
ATMOS ENERGY CORP
LOT 146
LOT 145
LOT 143, 144
TRINITY ROAD
E McKINNEY STREET &
McKINNEY STREET LLC
THE WOODLANDS ON
166+00 167+00 168+00 169+00 170+00
594.11
5/8" IRS W/RANDOM
40
D
X X X X X X X
FM
16" W16" W 16" W16" W
18" RCP 18" RCPD
FM
16" W 16" W16" W16" W 16" W16" W 18" RCP18" RCP
D
EX. GAS
(EMPTY UNTIL FUTURE EXTENSION)
18" RCP MATCHLINE STA 161+50MATCHLINE STA 166+00MATCHLINE STA 170+50MATCHLINE STA 166+0063
McKINNEY STREET
McKINNEY STREET
BY OTHERS
TO BE RELOCATED
EX. POWER POLE
BY OTHERS
TO BE RELOCATED
EX. POWER POLE
BY OTHERS
TO BE RELOCATED
EX. POWER POLEORR ROADBY OTHERS
TO BE RELOCATED
EX. POWER POLE
REMOVE TREE (TYP.)
(TYP.)
REMOVE TREE
TO BE REMOVED
WITHIN R.O.W. LIMITS
EX. POST AND WIRE FENCE
TO BE REMOVED
WITHIN R.O.W. LIMITS
EX. POST AND WIRE FENCE
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDM11.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDM11.dgn1:404:39:12 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
McKINNEY STREET
DEMOLITION PLAN
LEGEND
X
E. OF LOOP 288 TO W. OF GRISSOM ROAD
NOTES:
AL 2019
SEP
MISC. REMOVAL
TREE REMOVAL
PIPE OR CULVERT REMOVAL
CONCRETE SIDEWALK REMOVAL
CONCRETE DRIVEWAY REMOVAL
CONCRETE PAVEMENT REMOVAL
ASPHALT PAVEMENT REMOVAL
X
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
R.O.W. PREPARATION BID ITEM.
REMOVAL PAID FOR UNDER
CONTRACTOR REMOVING TREES. TREE
CITY APPROVAL REQUIRED PRIOR TO 5.
BE REPLACED.
APPROVAL. AREAS TO BE REMOVED MUST
TO BE REMOVED WITHOUT CITY
CONSTRUCTION. NO EXISTING SIDEWALK
STUDENT TRAFFIC THROUGHOUT
STREET SHALL BE MAINTAINED FOR
SIDEWALK ON NORTH SIDE OF McKINNEY 4.
PLANS FOR SIGN REMOVAL.
SEE PAVEMENT MARKING AND SIGNAGE 3.
ADDITIONAL REMOVAL ITEMS.
SEE WATER AND WASTEWATER SHEETS FOR 2.
TO CONSTRUCTION.
RELOCATED/ REMOVED BY OTHERS PRIOR
ALL UTILITIES IN CONFLICT TO BE 1.
S
S
S
587.06
5/8" IRS W/RANDOM
41
D
E McKINNEY STREET
ATMOS ENERGY CORP
E McKINNEY STREET & TRINITY ROAD
THE WOODLANDS ON McKINNEY STREET LLC
LOT 146
LOT 143, 144 LOT 143, 144
TRINITY ROAD
E McKINNEY STREET &
McKINNEY STREET LLC
THE WOODLANDS ON
TRINITY ROAD
E McKINNEY STREET &
ON McKINNEY STREET LLC
THE WOODLANDS
VOL. 695, PG. 351
16' UTILITY EASEMENT
VOL. XX, PG. XX
UTILITY EASEMENT
VARIABLE WIDTH
VOL. XX, PG. XX
25' UTILITY EASEMENT
VOL. XX, PG. XX
16' UTILITY EASEMENT
VOL. XX, PG. XX
EASEMENT
30' TEMPORARY CONSTRUCTION
171+00 172+00 173+00 174+00 175+00
16" W 16" W 16" W
21" WW
21" WW21" WW16" W 16" W 16" W
21" WW
21" WW21" WW18" RCPD
18" RCP
18" RCP
16" W
RCP18" FUTURE EXTENSION)
(EMPTY UNTIL
18" RCP
(EMPTY UNTIL FUTURE EXTENSION)
24" RCP
(EMPTY UNTIL FUTURE EXTENSION)
24" RCP
MATCHLINE STA 170+50McKINNEY STREET
BY OTHERS
TO BE RELOCATED
EX. POWER POLE
64
TO BE REMOVED
WITHIN R.O.W. LIMITS
EX. POST AND WIRE FENCE
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDM12.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDM12.dgn1:404:39:14 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
LEGEND
X
E. OF LOOP 288 TO W. OF GRISSOM ROAD
NOTES:
AL
MAYHILL ROAD
DEMOLITION PLAN
2019
SEP
MISC. REMOVAL
TREE REMOVAL
PIPE OR CULVERT REMOVAL
CONCRETE SIDEWALK REMOVAL
CONCRETE DRIVEWAY REMOVAL
CONCRETE PAVEMENT REMOVAL
ASPHALT PAVEMENT REMOVAL
X
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
R.O.W. PREPARATION BID ITEM.
REMOVAL PAID FOR UNDER
CONTRACTOR REMOVING TREES. TREE
CITY APPROVAL REQUIRED PRIOR TO 5.
BE REPLACED.
APPROVAL. AREAS TO BE REMOVED MUST
TO BE REMOVED WITHOUT CITY
CONSTRUCTION. NO EXISTING SIDEWALK
STUDENT TRAFFIC THROUGHOUT
STREET SHALL BE MAINTAINED FOR
SIDEWALK ON NORTH SIDE OF McKINNEY 4.
PLANS FOR SIGN REMOVAL.
SEE PAVEMENT MARKING AND SIGNAGE 3.
ADDITIONAL REMOVAL ITEMS.
SEE WATER AND WASTEWATER SHEETS FOR 2.
TO CONSTRUCTION.
RELOCATED/ REMOVED BY OTHERS PRIOR
ALL UTILITIES IN CONFLICT TO BE 1.CONCRETESSDDDDS3922 E McKINNEY STREET
GOEL VENTURES ONE, LLC
3923 E McKINNEY STREET
DENTON 3919 McKINNEY, LLC
E McKINNEY STREET (200' STRIP)
BCI REAL ESTATE VENTURES, LP
1516 E McKINNEY STREET
TALOUKIE BROS ENT INC
LOT 5R1 LOT 3
LOT 152
LOT 151 (PT)
LOT 5R2
4001 E McKINNEY STREET
CITY OF DENTON
CAB. B, PG. 71
25' UTILITY EASEMENT
CAB. Y, PG. 289
20' UTILITY EASEMENT
CAB. B, PG. 147
16' UTILITY EASEMENT12" W12" W12" W6" W12" W12"
W
20
" W
20" W20" W 20" W20" W12" W 12" W
8" W
12" W
12" W 8" WW10" WW 10" WW
8" WW
8" WW
8" WW10" WW 27" RCPBOX CULVERT
6'x4'
BOX CULVERT
6'x4'
BOX CULVERT6'x4'18" RCP 18" RCP 24" RCPBOX CULVERT6'x4'
BOX CULVERT
8'x4'
18" RCP
18" RCP18" RCP
BOX CULVERT
6'x4'
BOX CULVERT
8'x4'12" W(ABANDONED)
10" WW
(ABANDONED)10" WW
8" WW112+00113+00222+00
221+00
220+00
223+00 224+00 225+00
McKINNEY STREETS MAYHILL ROAD
N MAYHILL ROAD
65
BY OTHERS
TO BE RELOCATED
EX. POWER POLE
PAVEMENT
REMOVE ASPHALT GUTTER
MEDIAN AND CURB AND
REMOVE CONCRETE
6'X4' BOX CULVERT
REMOVE 224 LF
DRIVEWAY
REMOVE CONCRETE
PAVEMENT
REMOVE CONCRETE
57
DEMOLITION PLAN
McKINNEY STREET
SEE SH. FOR
REFERENCE ONLY
SIDEWALK
REMOVE CONCRETE
SIDEWALK
REMOVE CONCRETE
SIDEWALK
REMOVE CONCRETE SIDEWALK
REMOVE CONCRETE
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2X
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDM13.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDM13.dgn1:404:39:18 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
LEGEND
X
E. OF LOOP 288 TO W. OF GRISSOM ROAD
NOTES:
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
RYAN WAY
DEMOLITION PLAN
MISC. REMOVAL
TREE REMOVAL
PIPE OR CULVERT REMOVAL
CONCRETE SIDEWALK REMOVAL
CONCRETE DRIVEWAY REMOVAL
CONCRETE PAVEMENT REMOVAL
ASPHALT PAVEMENT REMOVAL
X
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
R.O.W. PREPARATION BID ITEM.
REMOVAL PAID FOR UNDER
CONTRACTOR REMOVING TREES. TREE
CITY APPROVAL REQUIRED PRIOR TO 5.
BE REPLACED.
APPROVAL. AREAS TO BE REMOVED MUST
TO BE REMOVED WITHOUT CITY
CONSTRUCTION. NO EXISTING SIDEWALK
STUDENT TRAFFIC THROUGHOUT
STREET SHALL BE MAINTAINED FOR
SIDEWALK ON NORTH SIDE OF McKINNEY 4.
PLANS FOR SIGN REMOVAL.
SEE PAVEMENT MARKING AND SIGNAGE 3.
ADDITIONAL REMOVAL ITEMS.
SEE WATER AND WASTEWATER SHEETS FOR 2.
TO CONSTRUCTION.
RELOCATED/ REMOVED BY OTHERS PRIOR
ALL UTILITIES IN CONFLICT TO BE 1.
PBX
E
3
6
"
T
R
E
EBCI REAL ESTATE VENTURES,LP
5090 E McKINNEY STREET
EDIBERTO A RODRIGUEZ
5101 E McKINNEY STREET
DENTON ISD
LOT 169
LOT 151 (PT)
LOT 150
LOT 1R4
5043 E McKINNEY STREET
CHELA DARLINE McDONALD
CAB. H, PG. 62
20' UTILITY EASEMENT
WVWVWV16" W16" W8" W8" W8" W10" W21" RCP24" RCP27" RCP15" RCP24" RCP PC 129+61.61
130+00131+00132+00McKINNEY STREET66
RYAN WAY
REMOVE CONCRETE PAVEMENT
CURB & GUTTER
REMOVE CONCRETE
59
DEMOLITION PLAN
McKINNEY STREET
SEE SH. FOR
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWONOTES:
FOR ADDITIONAL INFORMATION.
SEE WATER PLAN AND PROFILE SHEETS4.
ADDITIONAL INFORMATION.
SEE PAVING DETAILS SHEET FOR3.
FOR ADDITIONAL INFORMATION.
2. SEE DRAINAGE PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE CITY OF DENTON STANDARD DETAILS
McKINNEY STREET - PHASE 2
FINISHED GRADE.
CAP 4 INCHES ABOVE
OF PAVEMENT. TURN UP AND
TO EXTEND 12" BEYOND EDGE
MIN. 36" BELOW PROP. T.C.
2-6" PVC SCH 40 SLEEVES A
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV01.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV01.dgn1:404:39:22 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLPAVING PLAN & PROFILE
R305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
PARKING AREA
S
S
S
587.72
5/8" IRS W/RANDOM
3
0LOT 24A
LOOP 288
7-ELEVEN INC
LOT 1
LOT 1
101 N LOOP 288
DENNIS J KOOP
LOT 1
3612 E McKINNEY STREET
McKINNEY BUILDING, LP
VOL. 1029, PG. 281
UTILITY EASEMENT
75' MAINTAINING PUBLIC
VOL. 60
3,
PG. 520
EASEMENT
16' PUBL
IC UT
IL
ITY
CAB. R, PG. 32
EASEMENT
20' PUBLIC UTILITY
CAB. F, PG. 336ELEC. EASEMENT20' UTILITY &
VOL. 603, PG. 520
EASEMENT16' PUBL
IC UT
IL
ITY
101 S LOOP 288
INVESTMENT COMPANY
SEJ ASSET MANAGEMENT &
CAB. F, PG. 336& ELEC.EASEMENT16' UTILITY
D.R.D.C.T.
PG. 394
VOL. 440,
EASEMENT
DRAINAGE
40' TXDOT
WV
WV WV
LT
LT
LT
LT
LT30" WW3
0
" WW3
0
" WW8" WW8" WW
8" W
8" W8" W8" W2
0" W
2
0" W
8" W
24" RCP
36" RCP
36" RCP
BOX CULVERTEx. 9'
x
5' BOX CULVERTEx.
9'
x
5' BOX CULVERTEx.
9'
x
5' BOX CULVERTEx. 5'x4' BOX CULVERTEx.
5'x4' BOX CULVERTEx.
5'
x
4' BOX CULVERTEx.
5'
x
3' BOX CULVERTEx.
6'
x
3'
24" RCP
24" RCP
24" RCP
24
" RC
P
WV
2
0" W
PT 90+20.1888+00 90+00
91+00
87+00
1
0072+
0
0
100
7
3
+0
0
1
0
0
7
4
+0
0
89+00
24" RCP
4'X2' RCB
12" W
12" W
CONTENT
OPT. MOISTURE
BETWEEN 0 TO +3%
PER ASTM D698
MAX. DENSITY
TO MIN. 95%
COMPACTED FILL
TC LT
EX. TC
T.P. 587.42
T.C. 587.92
MATCH EX. PVM'T.
90+67.14,53.69' LT
(+)0.51 %
LT ROW
EX. GROUND AT
EX.(+)0.98 %587.78588.14588.09588.3491+00 588.41587.65588.40588.38CONTENT
OPT. MOISTURE
BETWEEN 0 TO +3%
PER ASTM D698
MAX. DENSITY
TO MIN. 95%
COMPACTED FILL
TC RTEX. TC
(+)0.51 %(-)0.53 %
T.P. 587.99
T.C. 588.49
MATCH EX. PVM'T.
90+76.91,30.08' RT
RT ROW
EX. GROUND AT
100' VC
TC 588.36SAG 91+27.82E = 0.13'
K = 96
EX. (-)1.30 %
588.49
VPC 90+77.00 TC 588.36(588.23)PI 91+27.00LEGEND:
PROPOSED PAVEMENT
DRIVEWAY
PROPOSED CONCRETE
FUTURE SIDEWALK
/SIDEWALK
SHALLOW PIPE
CONCRETE REPAIR
FULL DEPTH
EX. R.O.W
MATCHLINE STA 91+50595
590
585
PROP. TCEX.ROWPROP. TCEX.ROW67
CV-1
MATCHLINE STA 91+50595
590
585 N LOOP
2
8
8S LOOP
2
8
8
N = 7128212.49
E = 2399828.06
CURVE 1 (CV-1)
DEG = 6° 29' 50.28"
T = 164.90'
PI STA = 88+59.05
L = 326.03'
= 21° 11' 00.00" RT
R = 881.84'
354.41'
S 63° 20' 05.00" E
EX. R.O.W
EX. R.O.W
EX. R.O.W
6,
6
6
3.
4
1'
S
0
°
5
3'
0
6.62" W595
590
585
595
590
585
SUBGRADE (36 LB/SY PER LIFT) (TYP.)
AND 12" THICK LIME STABILIZED
W/ 9" THICK TYPE B ASPHALT BASE COURSE
3" THICK TYPE C ASPHALT SURFACE COURSE
STREETCL McKINNEY
LOOP 288
STA 10073+29.69
McKINNEY STREET=
STA 88+88.74
DENTON COUNTY, TX
MINUTES
COMMISIONER'S COURT
PAGE 366
ATTACHED TO VOL S,
DATED: 10-08-1947
RIGHT OF WAY EASEMENT
McKINNEY STREET
595
590
585
595
590
585
TP 588.68
TC 588.382.82%1.50%TC 588.34
3.05%EX. TC 588.40
TC 588.09
TP 588.912.76%EX. TP 588.752.09%2.98%AT STA 93+60.58
PAVEMENT TO TYP. SECTION
TRANSITION FROM EX.
BEGIN CROSS-SLOPE
TC 587.92
OFF 53.69' LT
STA 90+67.14
AT STA 93+60.58
PAVEMENT TO TYP. SECTION
TRANSITION FROM EX.
BEGIN CROSS-SLOPE
TC 588.49
OFF 30.08' RT
STA 90+76.91
BIKE/PED PATH
FUTURE 12'
SIDEWALK
FUTURE 6'
PIPE
SHALLOW
F.L. 584.36
T.C. 588.36
CL 10' REC. INLET
PAV STA 91+25.00, 29.95' RT
PIPE
SHALLOW
STREET HEADER
CONCRETE
REINFORCED
INSTALL 87 LF
PAVEMENT SECTION
STREET
BEGIN McKINNEY
STA 90+79.49
& GUTTER
24" CURB
CURB
MONOLITHIC
TY II
INCLUDING
REPAIR
CONCRETE
DEPTH
FULL
CURB
MONOLITHIC
TY II
INCLUDING
REPAIR
CONCRETE
DEPTH
FULL
NOSE
MEDIAN
MONOLITHIC
NOSE
MEDIAN
MONOLITHIC
GUTTER
CURB &
24"
1
2
4
POINTSMEDIAN
NO.STATION OFFSET
1 89+98.48 3.80
2 89+98.70 7.80
3 90+62.36 -1.00
4 90+62.68 3.00
STANDARD DETAILS.
SEE CITY OF DENTON
MEDIAN PAVEMENT.
4" THICK COLORED CONCRETE (B-B) 4'SIDEWALK
EXISTING
REPLACE
RAMP
TYPE 1A
DENTON
CITY OF
3 713.5'R700'R700'ROFF 54.37' LT
STA 90+75.25
OFF 54.65' LT
STA 90+79.06
200'R
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOLEGEND:
PROPOSED PAVEMENT
NOTES:
FOR ADDITIONAL INFORMATION.
SEE WATER PLAN AND PROFILE SHEETS4.
ADDITIONAL INFORMATION.
SEE PAVING DETAILS SHEET FOR3.
FOR ADDITIONAL INFORMATION.
2. SEE DRAINAGE PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE CITY OF DENTON STANDARD DETAILS
DRIVEWAY
PROPOSED CONCRETE
FUTURE SIDEWALK
McKINNEY STREET - PHASE 2
FINISHED GRADE.
CAP 4 INCHES ABOVE
OF PAVEMENT. TURN UP AND
TO EXTEND 12" BEYOND EDGE
MIN. 36" BELOW PROP. T.C.
2-6" PVC SCH 40 SLEEVES A
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV02.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV02.dgn1:404:39:25 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLPAVING PLAN & PROFILE
R305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
V
E
PARKING AREA
S
PARKING AREA
LOT 1
3730 E McKINNEY STREET
LISA FONG LEUNG
LOT 1
100 N LOOP 288
100 NORTH LOOP 288, LLC
LOT 41
101 S LOOP 288
DNB INVESTMENTS LTD
LOT 1
101 S LOOP 288
SEJ ASSET MANAGEMENT & INVESTMENT COMPANY
LOT 24A
LOOP 288
7-ELEVEN INC
VOL. 603, PG. 520
EASEMENT
16' PUBLIC UTILITY
CAB. R, PG. 32
EASEMENT
20' PUBLIC UTILITY CAB. D, PG. 191
16' UTILITY EASEMENT
WV
WV
8" WW 8" WW 8" WW
8" W8" W 8" W
8" W
8" W
8" W 8" W 8" W
24" RCP
18" RCP
15" RCP
24" RCP 8" W
20" W
PT 94+85.56 PC 93+74.5992+00 93+00 94+00 95+00 96+00
D18" RCP 18" RCP 18" RCP 18"
24" RCP
D
4'X2' RCB RCP30" 24" RCP
18"
12" W 12" W 12" W
12" W
20" W
20" W
20" W
20"
W
SLEEVES6" PVC
SLEEVES6" PVC SLEEVES6" PVC 6" W6" WCONTENT
OPT. MOISTURE
BETWEEN 0 TO +3%
PER ASTM D698
MAX. DENSITY
TO MIN. 95%
COMPACTED FILL
CONTENT
OPT. MOISTURE
BETWEEN 0 TO +3%
PER ASTM D698
MAX. DENSITY
TO MIN. 95%
COMPACTED FILL
TC LT
(+)0.51 %(-)0.50 %
(-)0.50 %(+)0.50 %100' VC589.11VPC 93+00.00 589.11VPT/VPC 94+00.00 100' VC
E = 0.13'
K = 100
589.11VPT 95+00.00 E = -0.13'
K = 99 TC 589.24CREST 93+50.53TC 588.99SAG 94+50.00LT ROW
EX. GROUND AT
AT LT ROW
EX. GROUND TC 589.24(589.36)PI 93+50.00TC 588.99(588.86)PI 94+50.00588.85589.37588.63587.10589.98590.05589.56589.39589.31590.25588.14588.60588.85589.11589.24589.11588.99589.11589.36589.61589.86588.3492+00 93+00 94+00 95+00 96+00588.46588.44588.41587.83587.88588.90588.95588.68588.49589.58589.63588.60588.85589.11589.24589.11588.99589.11589.36589.61589.86588.38CONTENT
OPT. MOISTURE
BETWEEN 0 TO +3%
PER ASTM D698
MAX. DENSITY
TO MIN. 95%
COMPACTED FILL
TC RT
(+)0.51 %(-)0.50 %
(-)0.50 %(+)0.50 %100' VC589.11VPC 93+00.00 589.11VPT/VPC 94+00.00 100' VC
E = 0.13'
K = 100
589.11VPT 95+00.00 E = -0.13'
K = 99 TC 589.24CREST 93+50.53TC 588.99SAG 94+50.00RT ROW
EX. GROUND AT
100' VC
E = 0.13'
K = 96
588.48VPT 91+77.00 (+)0.51 %TC 589.00STA 92+79.18CL DRIVETC 589.10STA 94+96.99CL DRIVETC 589.24(589.36)PI 93+50.00TC 588.99(588.86)PI 94+50.00SHALLOW PIPE
McKINNEY STREET
MATCHLINE STA 96+50595
590
585
EX. R.O.W
PROP. TCEX.ROWPROP. TCEX.ROW68
SUBGRADE (36 LB/SY PER LIFT) (TYP.)
AND 12" THICK LIME STABILIZED
W/ 9" THICK TYPE B ASPHALT BASE COURSE
3" THICK TYPE C ASPHALT SURFACE COURSE
CV-2
MATCHLINE STA 91+50595
590
585
MATCHLINE STA 91+50N = 7127954.53
E = 2400341.73
CURVE 2 (CV-2)
DEG = 1° 38' 13.28"
PI STA = 94+30.08
L = 110.97'MATCHLINE STA 96+50354.41'S 63° 20' 05.00" E
449.52'
S 61° 31' 05.00" E
= 1° 49' 00.00" RT
T = 55.49'
R = 3,500.00'
CL DRIVEWAY
STA 92+79.18 CL DRIVEWAY
STA 94+96.99
57' (B-B)10'R100' R.O.W.595
590
585
595
590
585
OFF 60.83' RT
STA 92+79.18
20'R 15'RCR 31.50' RT
STA 92+42.33
CR 31.50' RT
STA 93+17.82
CR 31.50' RT
STA 94+69.85
CR 31.50' RT
STA 95+23.75
23.4'
EX. R.O.W
& GUTTER
24" CURB
& GUTTER
24" CURB
15'R
OFF 72.24' RT
STA 94+96.99
F.L. 584.49
T.C. 588.99
CL 10' REC. INLET
PAV STA 94+50.00, 27.50' LT
2.00%TC 589.23
TC 589.23
TP 589.30
2.00%TC 589.11
TC 589.11
TP 589.251.73%2.25%TC 588.85
TP 589.07
TC 588.85
1.50%2.53%1.50%TC 588.60
TP 588.88
2.58%TC 588.60
TC 588.34
1.50%TC 588.38
TP 588.68
2.82%BEGIN TYP. SECTION
END CROSS-SLOPE TRANSITION
STA 93+60.58
SECTION
BEGIN TYP.
TRANSITION
END CROSS-SLOPE
STA 93+60.58
TRANSITION
BEGIN CROWN
STA 92+00
TRANSITION
END CROWN
3.00' RT
STA 92+50,
1
5'RPATH
12' BIKE/PED
FUTURE
FUTURE 6' SIDEWALK
DRIVEWAY (TYP.)
CONCRETE
REINFORCED
8" THICK
PIPE
SHALLOW 20'RSTREET
CL McKINNEY
F.L. 583.93
TH 588.43
TOP 589.43
4'x4' SQUARE DROP INLET
PAV STA 93+90.00, 45.00' LT
PIPE
SHALLOW
F.L. 584.99
T.C. 588.99
CL 10' REC. INLET
PAV STA 94+50.00, 33.50' RT
R.O.W
EX.
A
A
A713.5'ROFF 47.87' LT
STA 92+32.50
OFF 46.34' LT
STA 92+42.44
OFF 43.94' LT
STA 92+55.32
200'R200'ROFF 30.21' LT
STA 93+17.42
700'R700'R28.68' RT
OFF
91+64.99
STA
OFF 30.73' RT
STA 92+08.70
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOLEGEND:
PROPOSED PAVEMENT
NOTES:
FOR ADDITIONAL INFORMATION.
SEE WATER PLAN AND PROFILE SHEETS4.
ADDITIONAL INFORMATION.
SEE PAVING DETAILS SHEET FOR3.
FOR ADDITIONAL INFORMATION.
2. SEE DRAINAGE PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE CITY OF DENTON STANDARD DETAILS
DRIVEWAY
PROPOSED CONCRETE
FUTURE SIDEWALK
McKINNEY STREET - PHASE 2
FINISHED GRADE.
CAP 4 INCHES ABOVE
OF PAVEMENT. TURN UP AND
TO EXTEND 12" BEYOND EDGE
MIN. 36" BELOW PROP. T.C.
2-6" PVC SCH 40 SLEEVES A
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV03.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV03.dgn1:404:39:27 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLPAVING PLAN & PROFILE
R305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
V
V
PARKING AREA
S
S S
590.91
5/8" IRS W/RANDOM
31
LOT 1
E McKINNEY STREET
CCD-RLG DENTON I LP
LOT 1
3701 E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
LOT 1
3730 E McKINNEY STREET
LISA FONG LEUNG 191 DUCHESS DRIVE
JBJ/CALDER FUND VII JOINT VENTURE
LOT 1
CAB. D, PG. 191
16' UTILITY EASEMENT
CAB. D, PG. 15
20' PUBLIC UTILITY EASEMENT
CAB. O, PG. 264
EASEMENT
15' PUBLIC UTILITY
CAB. O, PG. 264
10' UTILITY EASEMENT
CAB. O, PG. 264
10' UTILITY EASEMENT
CAB. XX, PG. XX
EASEMENT
PRIVATE DRAINAGE
CAB. X, PG. XX
EASEMENT
8' PUBLIC UTILITY
WV
WV
WV
8" WW
8" WW 8" WW
8" W 8" W 8" W 8" W
8" W
8" W 8" W 6" W(15" STEEL ENCASEMENT)8" WW(15" STEEL ENCASEMENT)8" WW8" WW8" W8
" W6" W
6" W6" W
6" W
T PC 99+35.0897+00 98+00 99+00 100+00 101+00
24" RCP
18" RCP
D18"
D
20" W
12" W 12" W 12" W 12" W
20" W 20" W
20" W
6" W6" WSLEEVES
6" PVC
SLEEVES6" PVC SLEEVES6" PVC 6" WTC LT
(+)0.50 %(-)0.76 %
100' VC
E = -0.16'
K = 79 590.23VPT 98+50.00 590.36VPC 97+50.00 LT ROW
EX. GROUND AT TC 590.46CREST 97+89.56TC 589.31STA 99+70.55CL DRIVETC 590.46(590.61)PI 98+00.00 592.60592.44590.60591.27590.25589.54590.51590.53590.05592.27590.58590.11590.36590.46590.23589.85589.47589.09588.71588.32587.94589.86CONTENT
OPT. MOISTURE
BETWEEN 0 TO +3%
PER ASTM D698
MAX. DENSITY
TO MIN. 95%
COMPACTED FILL
TC RT
(+)0.50 %(-)0.76 %
100' VC
E = -0.16'
K = 79 590.23VPT 98+50.00 590.36VPC 97+50.00 RT ROW
EX. GROUND AT TC 590.46CREST 97+89.56DUCHESS DRIVETC 590.46(590.61)PI 98+00.00 97+00 98+00 99+00 100+00 101+00588.35588.67587.83588.90589.01588.80589.25589.62590.40590.41589.17590.11590.36590.46590.23589.85589.47589.09588.71588.32587.94589.86CL McKINNEY STREET
McKINNEY STREET
MATCHLINE STA 101+50595
590
585
595
590
585
PROP. TCEX.ROWPROP. TCEX.ROWSUBGRADE (36 LB/SY PER LIFT) (TYP.)
AND 12" THICK LIME STABILIZED
W/ 9" THICK TYPE B ASPHALT BASE COURSE
3" THICK TYPE C ASPHALT SURFACE COURSEMATCHLINE STA 96+50595
590
585
595
590
585 MATCHLINE STA 96+50N = 7127635.39
E = 2400929.96
CURVE 3 (CV-3)
DEG = 1° 05' 28.85"
PI STA = 100+99.31
L = 328.34'MATCHLINE STA 101+50449.52'
S 61° 31' 05.00" E
= 3° 35' 00.00" LT
R = 5,250.00'
T = 164.22'
CV-3
69DRIVEDUCHESS 57' (B-B)57' (B-B)CONCRETE DRIVEWAY
8" THICK REINFORCED
CONCRETE DRIVEWAY
8" THICK REINFORCED
FENCEIRON
EX. WROUGHT
CL DUCHESS DRIVE
STA 99+62.87
CL DRIVE
STA 99+70.55 100' R.O.W.OFF 96.12' RT
STA 99+40.58 231.90'S 28° 10' 43.24" WEX. R.O.W
EX. R.O.W
LOT 1
3730 E McKINNEY STREET
LISA FONG LEUNG
EX. R.O.W
EX. R.O.W
30'R30'R30'R30'R5'R10'R6'RCR 25.50' LT
STA 99+13.19
CR 25.50' LT
STA 100+13.91
CR 31.50' RT
STA 99+08.91
CR 31.50' RT
STA 100+15.43
CR 61.09' RT
STA 99+85.78
33'
& GUTTER
24" CURB
& GUTTER
24" CURB
CR 58.49' RT
STA 99+38.71
OFF 96.28' RT
STA 99+62.87
PATH
12' BIKE/PED
FUTURE
FUTURE 6' SIDEWALK
PATH
12' BIKE/PED
FUTURE F.L. 584.21
T.C. 588.71
CL 10' REC. INLET
PAV STA 100+50.00, 27.50' LT
R.O.W
EX.
F.L. 584.21
T.C. 588.71
CL 10' REC. INLET
PAV STA 100+50.00, 33.50' RT
F.L. 585.74
TH 590.74
TOP 591.74
4'x4' SQUARE DROP INLET
PAV STA 97+40.00, 63.00' LT
SLEEVES6" PVC
6 'RA
A
A
TYPE 1A RAMP
CITY OF DENTON
TYPE 1A RAMP
CITY OF DENTON
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOLEGEND:
PROPOSED PAVEMENT
NOTES:
FOR ADDITIONAL INFORMATION.
SEE WATER PLAN AND PROFILE SHEETS4.
ADDITIONAL INFORMATION.
SEE PAVING DETAILS SHEET FOR3.
FOR ADDITIONAL INFORMATION.
2. SEE DRAINAGE PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE CITY OF DENTON STANDARD DETAILS
DRIVEWAY
PROPOSED CONCRETE
FUTURE SIDEWALK
McKINNEY STREET - PHASE 2
FINISHED GRADE.
CAP 4 INCHES ABOVE
OF PAVEMENT. TURN UP AND
TO EXTEND 12" BEYOND EDGE
MIN. 36" BELOW PROP. T.C.
2-6" PVC SCH 40 SLEEVES A
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV04.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV04.dgn1:404:39:30 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLPAVING PLAN & PROFILE
R305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
E
DBL. 10" HACKBERRY
18" ELM 6" TREE
TRI 4" TREE
QUAD 6" ELM
DBL. 8" HACKBERRY 6" ELM DBL. 6"/12" HACKBERRY DBL. 6" HACKBERRY DBL. 8" HACKBERRY
4" ELM
6" ELM
DBL. 12" HACKBERRY
DBL. 6" ELM
10" TREE
S
586.24
X CUT SET
32
LOT 1
191 DUCHESS DRIVE
JBJ/CALDER FUND VII JOINT VENTURE
LOT 27
E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
LOT 29
E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
STREET
3910 E McKINNEY
SCOTTIE ADAMS
LOT 1
CAB. D, PG. 15
20' PUBLIC UTILITY EASEMENT
CAB. O, PG. 264
10' UTILITY EASEMENT
CAB. O, PG. 264
10' UTILITY EASEMENT
CAB. B, PG. 71
25' UTILITY EASEMENT
CAB. B, PG. 71
16' UTILITY EASEMENT
8" W
8" W 8" W
6" W
6" W
6" W6" W
6
" W6" W
8" WW
15" RCP PT 102+63.42 PC 104+55.99102+00 103+00 104+00 105+00
106+00
24" RCP18" RCP18" RCPD18"
RCP36" RCP18"
12" W
20" W 20" W 20" W 20" W
12" W 12" W
12" W
SLEEVES6" PVC 6" W6" WTC LT
(-)0.76 %
LT ROW
EX. GROUND AT
(-)0.52 %585.65PI 104+50.00BEGIN CROWN TRANSITION
585.59589.54587.23587.86586.84586.23588.61588.19588.69588.58587.56587.18586.80586.41586.03587.94585.65585.39585.13584.87TC RT
(-)0.90 %(-)0.76 %
RT ROW
EX. GROUND AT TC 584.62STA 105+64.64CL DRIVE585.65PI 104+50.00102+00 103+00 104+00 105+00 106+00586.48585.26588.80584.53586.93586.08587.23587.47587.94588.31587.56587.18586.80586.41586.03585.65585.20584.75584.30587.94584.30584.53CL McKINNEY STREET
McKINNEY STREET
MATCHLINE STA 106+00590
585
580
EX. R.O.W
PROP. TCEX.ROWPROP. TCEX.ROWSUBGRADE (36 LB/SY PER LIFT) (TYP.)
AND 12" THICK LIME STABILIZED
W/ 9" THICK TYPE B ASPHALT BASE COURSE
3" THICK TYPE C ASPHALT SURFACE COURSE
590
585
580 MATCHLINE STA 101+50MATCHLINE STA 101+50192.57'
S 65° 06' 05.00" E
CV-3
70MATCHLINE STA 106+00N = 7127416.80
E = 2401400.90
CURVE 4 (CV-4)
DEG = 3° 30' 02.71"
PI STA = 106+18.39
L = 323.74'
R = 1,636.67'
T = 162.40'
N = 7127635.39
E = 2400929.96
CURVE 3 (CV3)
DEG = 1° 05' 28.85"
PI STA = 100+99.31
L = 328.34'
= 3° 35' 00.00" LT
R = 5,250.00'
T = 164.22'
CV-4
= 11° 20' 00.00" LT
CONCRETE DRIVEWAY
8" THICK REINFORCED
EX. R.O.W
FENCEIRON
EX. WROUGHT
FENCEIRON
EX. WROUGHT 100' R.O.W.CL DRIVEWAY
STA 105+64.64
57' (B-B)OFF 60.50' RT
STA 105+71.75
15'R
CR 31.50' RT
STA 105+38.99
& GUTTER
24" CURB
& GUTTER
24" CURB
590
585
580
590
585
580
PATH
12' BIKE/PED
FUTURE
SIDEWALK
FUTURE 6'
F.L. 580.63
T.C. 585.13
CL 10' REC. INLET
PAV STA 105+50.00, 27.50' LT
F.L. 579.54
TH 585.54
TOP 586.54
6'x6' SQUARE DROP INLET
PAV STA 105+50.00, 42.00' LT
F.L. 582.30
T.C. 586.80
CL 10' REC. INLET
PAV STA 103+00.00, 27.50' LT
F.L. 580.70
T.C. 585.20
CL 10' REC. INLET
PAV STA 105+00.00, 33.50' RT 15'RSLEEVES6" PVC
A
CR 31.50' RT
STA 105+92.02
DONE BY OTHERS TO STA 119+50
CONTRACT, BEGIN WORK TO BE
STA 106+00 END WORK THIS
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOLEGEND:
PROPOSED PAVEMENT
NOTES:
FOR ADDITIONAL INFORMATION.
SEE WATER PLAN AND PROFILE SHEETS4.
ADDITIONAL INFORMATION.
SEE PAVING DETAILS SHEET FOR3.
FOR ADDITIONAL INFORMATION.
2. SEE DRAINAGE PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE CITY OF DENTON STANDARD DETAILS
DRIVEWAY
PROPOSED CONCRETE
FUTURE SIDEWALK
McKINNEY STREET - PHASE 2
FINISHED GRADE.
CAP 4 INCHES ABOVE
OF PAVEMENT. TURN UP AND
TO EXTEND 12" BEYOND EDGE
MIN. 36" BELOW PROP. T.C.
2-6" PVC SCH 40 SLEEVES A
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV05.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV05.dgn1:404:39:32 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLPAVING PLAN & PROFILE
R305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
V
PARKING AREA PARKING AREA
PARKING AREA
CONCRETE
PARKING AREA
PARKING AREA
PARKING AREA
24" HACKBERRYDBL. 12" TREE24" TREETRI 6" TREE
15" HACKBERRY10" CEDAR
DBL. 10" TREE
DBL. 12" HACKBERRY
S
LOT 38
LOT 4LOT 3LOT 2
3912 E McKINNEY STREET
DUNCAN STREET COMMERCIAL LLC
LOT 1
3910 E McKINNEY STREET
SCOTTIE ADAMS
LOT 29
E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
3801 E McKINNEY STREET
ANGEL & GRISELDA ENRIQUEZ
3919/3921 E McKINNEY STREET
NSA PROPERTY HOLDINGS, LLC
LOT 1R
3916 E McKINNEY STREET
EDWARD D & SHARYL K DIELEMAN
3918-3920 E McKINNEY STREET
LESLIE A & MICHAEL L ORINGDERFF
CAB. B, PG. 71
25' UTILITY EASEMENTCAB. B, PG. 71
16' UTILITY EASEMENT
CAB. Y, PG. 289
20' UTILITY EASEMENT
McKINNEY STREET
3919/3921 E
HOLDINGS, LLC
NSA PROPERTY
WV
WVWV
WV6" W
6" W
8" WW
8" WW 8" WW
8" W 8" W 8" W
6" W6" W
6" W
8" WW 8" WW
15" RCP
24" RCP
18" RCP
15" RCP
18" RCP 18" RCP
18" RCP
8" WW PT 107+79.73106+00
107+00 108+00 109+00 110+00
36" RCP 24"18"36" RCP
D 18"30" RCP24" RCP18"18"
R
C
P18"RCB
4'X4'
RCB
4'X4'
RCB
4'X4'
20" W
12" W
12" W 12" W 12" W
20" W 20" W 20" W
12" W12" WSLEEVES
6" PVC
SLEEVES
6" PVC
SLEEVES
6" PVC
SLEEVES
6" PVC
SLEEVES
6" PVC
SLEEVES6" PVC
SLEEVES6" PVC
TC LT (+)1.00 %TC 582.80SAG 110+23.46LT ROW
EX. GROUND AT 582.89VPC 109+90.00 100' VC
E=0.19'
K=67
TC 584.02STA 107+64.78CL DRIVETC 583.47STA 108+73.87CL DRIVETC 582.81STA 110+15.30CL DRIVE(-)0.52 %(-)0.50 %
(-)0.50 %584.09PI 107+50.00TC 582.82(582.64)PI 110+40.00 END CROWN TRANSITION BEGIN NO CROWN
585.59584.53584.73584.65584.90584.22584.94584.19585.31584.79584.61584.35584.09583.84583.59583.34583.09582.84582.86584.87CONTENT
OPT. MOISTURE
BETWEEN 0 TO +3%
PER ASTM D698
MAX. DENSITY
TO MIN. 95%
COMPACTED FILL
CONTENT
OPT. MOISTURE
BETWEEN 0 TO +3%
PER ASTM D698
MAX. DENSITY
TO MIN. 95%
COMPACTED FILL
TC RT
(+)1.00 %TC 581.66SAG 110+23.46TC 583.23STA 107+19.34CL DRIVETC 582.66STA 108+08.75CL DRIVEAT RT ROW
EX. GROUND TC 582.04STA 109+31.66CL DRIVETC 581.76STA 109+87.19CL DRIVE(-)0.90 %(-)0.50 %(-)0.50 %
100' VC
E=0.19'
K=67
581.75VPC 109+90.00 582.95PI 107+50.00TC 581.68(581.50)PI 110+40.00 106+00 107+00 108+00 109+00 110+00581.36580.77581.31581.11582.47582.75584.18582.50584.53584.19584.30583.85584.30583.40582.95582.70582.45582.20581.95581.70581.72584.53EX. R.O.W
MATCHLINE STA 110+50590
585
580
590
585
580
PROP. TCEX.ROWPROP. TCEX.ROW590
585
580
590
585
580 MATCHLINE STA 106+00372.44'
S 76° 26' 05.00" E
71MATCHLINE STA 106+00N = 7127416.80
E = 2401400.90
CURVE 4 (CV-4)
DEG = 3° 30' 02.71"
PI STA = 106+18.39
L = 323.74'
R = 1,636.67'
T = 162.40'
CV-4
= 11° 20' 00.00" LTMATCHLINE STA 110+50CL DRIVEWAY
STA 107+19.34
CL DRIVEWAY
STA 107+64.78
CL DRIVEWAY
STA 108+08.75
CL DRIVEWAY
STA 108+73.87
CL DRIVEWAY
STA 110+15.30
CL DRIVEWAY
STA 109+87.19
CL DRIVEWAY
STA 109+31.6657' (B-B)100' R.O.W.FENCE
EX. IRON
IRON FENCE
EX. WROUGHT
R.O.W
EX.
STREET
CL McKINNEY 15'R1
5'R20'R20'R15'R1
5'R
1
0'R20'R20'RCR 25.50' LT
STA 107+29.25
CR 25.50' LT
STA 108+00.66
CR 31.50' RT
STA 106+92.71
CR 31.50' RT
STA 107+48.43
30'
32.2'
CR 31.50' RT
STA 108+39.46
47.7'
CR 33.45' RT
STA 109+59.18
CR 31.50' RT
STA 109+02.77
CR 33.45' RT
STA 109+68.39
CR 31.50' RT
STA 110+08.52
CR 25.50' LT
STA 110+48.99
CR 25.50' LT
STA 109+84.47
F.L. 578.28
TH 583.28
TOP 584.28
4'x4' SQUARE DROP INLET
PAV STA 108+35.00, 42.00' LT
F.L. 577.80
T.C. 582.30
CL 20' REC. INLET
PAV STA 108+80.00, 33.50' RT
& GUTTER
24" CURB
& GUTTER
24" CURB
10'
R
30.3'23.4'
CR 52.20' RT
STA 107+19.34
OFF 59.93' RT
STA 110+15.30
5'R
STREET
McKINNEY
CR 25.50' LT
STA 109+08.87,
PATH
12' BIKE/PED
FUTURE 8'R8'ROFF 34.38' RT
STA 107+86.89
(TYP.)
CONCRETE DRIVEWAY
8" THICK REINFORCED
SUBGRADE (36 LB/SY PER LIFT) (TYP.)
AND 12" THICK LIME STABILIZED
W/ 9" THICK TYPE B ASPHALT BASE COURSE
3" THICK TYPE C ASPHALT SURFACE COURSE
F.L. 578.21
TH 583.71
TOP 584.71
5'X5' SQUARE DROP INLET
PAV STA 107+30.00, 42.00' LT
30.8'
25.50' LT
108+39.23
STA
OFF 57.36' LT
STA 108+73.87 F.L. 579.41
TOP 583.91
W/2' RIP-RAP APRON
TWO-GRATE INLET
PAV STA 109+20.00, 45.50' LT
F.L. 578.36
TOP 583.36
SIX-GRATE INLET
PAV STA 110+15.00, 47.50' LT
INLET.
DRAIN TO GRATE
EXISTING FLUME TO
FINISHED GRADE.
SET 0.1' BELOW
TOP OF GRATE INLET
F.L. 579.22
T.C. 583.72
CL 10' REC. INLET
PAV STA 106+65.00, 33.50' RT
F.L. 578.37
T.C. 582.87
CL 10' REC. INLET
PAV STA 107+65.00, 33.50' RT
F.L. 577.38
T.C. 581.88
CL 5' STD. INLET
33.50' RT
PAV STA 109+63.80,
F.L. 577.17
T.C. 581.67
CL 15' REC. INLET
33.50' RT
PAV STA 110+30.00,
REFERENCE ONLY
6' SIDEWALK
FUTURE 15'R15'R1
5'RA A A A
AA
A
STA 107+50.00
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOLEGEND:
PROPOSED PAVEMENT
DRIVEWAY/SIDEWALK
PROPOSED CONCRETE
NOTES:
INFORMATION.
SEE MAYHILL RD SHEETS FOR ADDITIONAL6.
ADDITIONAL INFORMATION.
SEE TRAFFIC SIGNAL PLANS FOR5.
INFORMATION.
SEE LANDSCAPE SHEETS FOR ADDITIONAL4.
FOR ADDITIONAL INFORMATION.
SEE WATER PLAN AND PROFILE SHEETS3.
FOR ADDITIONAL INFORMATION.
2. SEE DRAINAGE PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE CITY OF DENTON STANDARD DETAILS
McKINNEY STREET - PHASE 2
FUTURE SIDEWALK
FINISHED GRADE.
CAP 4 INCHES ABOVE
OF PAVEMENT. TURN UP AND
TO EXTEND 12" BEYOND EDGE
MIN. 36" BELOW PROP. T.C.
2-6" PVC SCH 40 SLEEVE A
PTZ
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV06.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV06.dgn1:404:39:35 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLPAVING PLAN & PROFILE
R305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
CONCRETE
CONCRETE
E
E
PARKING AREA
S
S
S
D
D
S
585.34
PK NAIL SET
33
S
LOT 153
LOT 3
LOT 151 (PT)
E McKINNEY STREET (200' STRIP)
BCI REAL ESTATE VENTURES, LP
LOT 5R1
LOT 152
STREET
4001 E McKINNEY
CITY OF DENTON
E McKINNEY STREET
CITY OF DENTON
3922 E McKINNEY STREET
GOEL VENTURES ONE, LLC
3918-3920 E McKINNEY STREET
LESLIE A & MICHAEL L ORINGDERFF
3923 E McKINNEY STREET
DENTON 3919 McKINNEY, LLC
CAB. B, PG. 71
25' UTILITY EASEMENT
CAB. Y, PG. 289
20' UTILITY EASEMENT
CAB. B, PG. 147
16' UTILITY EASEMENT
VOL. 5039, PG. 01970
DRAINAGE EASEMENT
20' PERMANENT
McKINNEY STREET
3919/3921 E
HOLDINGS, LLC
NSA PROPERTY
LOT 1R
8" WW
8" W
6" W
12" W
12" W12" W6" W 12" W 12" W 20" W16" W
20" W20" W20" W
20" W
8" WW 10"
WW8" WW8" WW10" WW8" W12"
W20" W 12" W
12" W8" W
8" W
8" WW 8" WW8" WW
2-18" RCP
27" RCP
BOX CULVERT6'x4'BOX CULVERT6'
x
4'BOX CULVERT6'x4'18"
RCPB
O
X
C
U
L
V
E
R
T
6'x4'
8" WW
(ABANDONED)10"
WW(AB
AND
ONE
D)
1
0" WW8" WW
10'x4' RCBC PT 112+56.89 PC 111+52.17111+00 112+00 113+00 114+00 115+00
222+00223+00224+00 PT 222+80.64
BOX CULVERT5'x4'18" RCP18"18" RCPD18"BOX CULVERT6'x4'BOX CULVERT6'x4'RCP24" RCP24" D
4'X4' RCBRCB
4'X4'20" W12" W
12" W16" W 16" W10" WW20" W
SLEEVES6" PVC SLEEVES6" PVC
SLEEVES6" PVC SLEEVES6" PVC 6" WCONTENT
OPT. MOISTURE
BETWEEN 0 TO +3%
PER ASTM D698
MAX. DENSITY
TO MIN. 95%
COMPACTED FILL
TC LT
E = 0.19'
K = 67
100' VC
(+)0.50 %
(+)0.50 %583.13VPT 110+90.00 584.64PI 112+19.63 584.90PI 113+19.34 585.75VPC 114+90.00 120' VCTC 585.82CREST 115+14.81MAYHILL ROADAT LT ROW
EX. GROUND
(+)1.00 %(+)1.00 %(+)1.30 %583.73PI 111+50.00 E=-0.36'
K=50
RCB
5'X4'
PROP. TC 582.82(582.64)PI 110+40.00 TC 585.69(586.05)PI 115+50.00BEGIN CROWN TRANSITIONEND NO CROWN
584.26584.90583.83585.03585.98586.13585.49584.72583.93584.03584.73584.72584.85585.05585.30585.55585.79585.69583.23583.73584.38582.86CONTENT
OPT. MOISTURE
BETWEEN 0 TO +3%
PER ASTM D698
MAX. DENSITY
TO MIN. 95%
COMPACTED FILL
CONTENT
OPT. MOISTURE
BETWEEN 0 TO +3%
PER ASTM D698
MAX. DENSITY
TO MIN. 95%
COMPACTED FILL
TC RT (+)0.75 %
100' VC
E=0.19'
K=67
(+)0.63 %(+)0.63 %(+)0.75 %
120' VC584.71VPC 114+90.00 TC 584.86CREST 115+27.38RT ROW
EX. GROUND AT TC 581.90STA 110+80.22CL DRIVEMAYHILL ROAD(+)1.00 %
(+)1.00 %581.99VPT 110+90.00 583.42PI 112+32.96584.41PI 114+50.00583.75PI 113+44.60RCB
5'X4'
PROP. E=-0.36'
K=50 TC 584.80(585.17)PI 115+50.00111+00 112+00 113+00 114+00 115+00580.62580.70580.12581.88582.56582.92582.88580.68580.86581.34580.77583.47583.62583.78584.10584.41584.78584.80580.77582.09582.59583.09583.47581.72EX. R.O.W
CL McKINNEY STREET
590
585
580
590
585
580
PROP. TCEX.ROWPROP. TCEX.ROWSUBGRADE (36 LB/SY PER LIFT) (TYP.)
AND 12" THICK LIME STABILIZED
W/ 9" THICK TYPE B ASPHALT BASE COURSE
3" THICK TYPE C ASPHALT SURFACE COURSE
590
585
580
590
585
580 MATCHLINE STA 110+50372.44'
S 76° 26' 05.00" E
72
N = 7127279.07
E = 2401971.72
CURVE 5 (CV-5)
DEG = 0° 38' 11.83"
PI STA = 112+04.53
L = 104.72'
CV-5
MATCHLINE STA 110+50424.94'
S 75° 46' 05.00" E
= 0° 40' 00.00" RT
T = 52.36'S MAYHI
LL ROADCL DRIVEWAY
STA 110+80.22
EX. R.O.W
57' (B-B)57' (B-B)OFF 63.95' LT
STA 112+08.15
OFF 80.31' LT
STA 113+05.99
100' R.O.W.OFF 50.80' LT
STA 112+05.36
MATCHLINE STA 115+50MATCHLINE STA 115+50R = 9,000.00'
5' SIDEWALK
STREET
McKINNEY
10' SIDEWALK
10' SIDEWALK
STA 222+65.23 MAYHILL ROAD
STA 112+75.57 McKINNEY STREET
15'R1
0'R
CONCRETE DRIVEWAY
8" THICK REINFORCED
CR 31.50' RT
STA 110+53.90
CR 31.50' RT
STA 111+06.55
29'30'R30'R30'R
30'R
CR 25.50' LT
STA 111+76.15
CR 25.50' LT
STA 113+42.91
CR 31.50' RT
STA 113+81.28
CR 67.19' RT
STA 113+51.8320'RCR 31.50' RT
STA 112+08.56
CR 55.42' RT
STA 112+38.14
CR 48.40' LT
STA 113+13.76
& GUTTER
24" CURB
& GUTTER
24" CURB
& GUTTER
24" CURB
CONCRETE DRIVEWAY
REINFORCED
8" THICK
INFORMATION.
SEE MAYHILL RD SHEETS FOR ADDITIONAL6.
ADDITIONAL INFORMATION.
SEE TRAFFIC SIGNAL PLANS FOR5.
INFORMATION.
SEE LANDSCAPE SHEETS FOR ADDITIONAL4.
FOR ADDITIONAL INFORMATION.
SEE WATER PLAN AND PROFILE SHEETS3.
FOR ADDITIONAL INFORMATION.
2. SEE DRAINAGE PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE CITY OF DENTON STANDARD DETAILSROADN MAYHI
LL
FUTURE 12' BIKE/PED PATH
SIDEWALK
FUTURE 5'
FUTURE 6' SIDEWALK
PATH
12' BIKE/PED
FUTURE
83
PAVING PLAN AND PROFILE
MAYHILL ROAD
SEE SH. FOR
R.O.W
EX.
F.L. 579.43
TOP 583.93
W/2' RIP-RAP APRON
SIX-GRATE INLET
PAV STA 110+75.00, 45.50' LT
F.L. 577.84
T.C. 582.34
CL 10' REC. INLET
PAV STA 111+25.00, 33.50' RT LINK FENCE
EX. CHAIN
EX. R.O.W6' SIDEWALK
FUTURE
& GUTTER
24" CURB
F.L. 579.60
T.C. 584.10
CL 10' REC. INLET
PAV STA 114+00.00, 33.50' RT
REFERENCE ONLY
A A
A
A
STA 114+50.00
CONCRETE STREET HEADER
INSTALL 57 LF REINFORCEDSTREET HEADER
CONCRETE
REINFORCED
INSTALL 57 LF
TYPE 1B RAMP
CITY OF DENTON
TYPE 1A RAMP
CITY OF DENTON
TYPE 1A RAMP
CITY OF DENTON
TYPE 1B RAMP
CITY OF DENTON
TYPE 1B RAMP
CITY OF DENTON
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOLEGEND:
PROPOSED PAVEMENT
NOTES:
FOR ADDITIONAL INFORMATION.
SEE WATER PLAN AND PROFILE SHEETS4.
ADDITIONAL INFORMATION.
SEE PAVING DETAILS SHEET FOR3.
FOR ADDITIONAL INFORMATION.
2. SEE DRAINAGE PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE CITY OF DENTON STANDARD DETAILS
DRIVEWAY
PROPOSED CONCRETE
FUTURE SIDEWALK
McKINNEY STREET - PHASE 2
FINISHED GRADE.
CAP 4 INCHES ABOVE
OF PAVEMENT. TURN UP AND
TO EXTEND 12" BEYOND EDGE
MIN. 36" BELOW PROP. T.C.
2-6" PVC SCH 40 SLEEVES A
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV07.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV07.dgn1:404:39:38 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLPAVING PLAN & PROFILE
R305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
LOT 151 (PT)
E McKINNEY STREET (200' STRIP)
BCI REAL ESTATE VENTURES, LP
LOT 159
4301 E McKINNEY STREET
CITY OF DENTON
LOT 154
4393 E McKINNEY STREET
KENNETH L & GLADYS F STOUT
WV16" W 16" W 16" W
8" W 8" W
8" WW 8" WW
15" CMP 15" CMP
PC 116+81.83116+00 117+00 118+00 119+0018"5'X2' RCB5'X2' RCB 5'X2' RCB
18" RCP
RCP
24"
16" W 16" W 16" W
SLEEVES6" PVC
CONTENT
OPT. MOISTURE
BETWEEN 0 TO +3%
PER ASTM D698
MAX. DENSITY
TO MIN. 95%
COMPACTED FILL
TC LT
(-)1.92 %
(-)1.92 %(+)0.55 %584.90VPT 116+10.00 120' VC
E = -0.36'
K = 50 584.71VPC 116+20.00583.61VPT 117+80.00160' VC
E = -0.49'
K = 65
(+)0.55 %
LT ROW
EX. GROUND AT 584.27PI 119+00.00 TC 583.52SAG 117+44.49TC 583.59STA 117+76.09CL DRIVERCB
5'X4'
PROP. TC 585.69(586.05)PI 115+50.00TC 583.67(583.18)PI 117+00.00END CROWN TRANSITION
STA 119+00.00
584.40584.77584.49584.52583.97584.57584.83583.83585.08584.20583.67583.52583.72584.00584.27585.69CONTENT
OPT. MOISTURE
BETWEEN 0 TO +3%
PER ASTM D698
MAX. DENSITY
TO MIN. 95%
COMPACTED FILL
TC RT
RT ROW
EX. GROUND AT
(-)1.67 %
(-)1.67 %
(-)1.67 %(+)0.80 %
(+)0.80 %
120' VC
E = -0.36'
K = 50 584.17VPT 116+10.00 584.00VPC 116+20.00160' VC
E = 0.49'
K = 65
583.31VPT 117+80.00TC 583.10SAG 117+28.08584.27PI 119+00.00 RCB
5'X4'
PROP. TC 584.80(585.17)PI 115+50.00TC 583.16(582.67)PI 117+00.00116+00 117+00 118+00 119+00582.49584.08580.46581.27580.00580.37580.66584.32583.57583.16583.14583.47583.87584.27584.80580.12584.08584.27CL McKINNEY STREET
McKINNEY STREET
590
585
580
590
585
580
PROP. TCEX.ROWPROP. TCEX.ROWSUBGRADE (36 LB/SY PER LIFT) (TYP.)
AND 12" THICK LIME STABILIZED
W/ 9" THICK TYPE B ASPHALT BASE COURSE
3" THICK TYPE C ASPHALT SURFACE COURSE
590
585
580
590
585
580 MATCHLINE STA 115+5073
N = 7127057.59
E = 2402844.97
CURVE 6 (CV-6)
DEG = 0° 29' 59.69"
PI STA = 121+05.43
L = 846.81'MATCHLINE STA 115+50424.94'
S 75° 46' 05.00" E
= 4° 14' 00.00" RT
CL DRIVEWAY
STA 117+75.90
EX. R.O.W
EX. R.O.W
57' (B-B)100' R.O.W.T = 423.60'
R = 11,461.16'
CONCRETE DRIVEWAY
8" THICK REINFORCED MATCHLINE STA 119+001
5'RCR 26.15' LT
STA 117+54.03
CR 25.50' LT
STA 117+99.85
MATCHLINE STA 119+00CV-6
& GUTTER
24" CURB
OFF 65.00' LT
STA 117+71.44
PATH
12' BIKE/PED
FUTURE
FUTURE 6' SIDEWALK
F.L. 578.60
T.C. 583.10
CL 15' REC. INLET
PAV STA 117+30.00, 33.50' RT
F.L. 579.03
T.C. 583.53
CL 10' REC. INLET
PAV STA 117+35.00, 27.50' LT
REFERENCE ONLY
1 5 'R& GUTTER
24" CURB
A
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOLEGEND:
PROPOSED PAVEMENT
NOTES:
FOR ADDITIONAL INFORMATION.
SEE WATER PLAN AND PROFILE SHEETS4.
ADDITIONAL INFORMATION.
SEE PAVING DETAILS SHEET FOR3.
FOR ADDITIONAL INFORMATION.
2. SEE DRAINAGE PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE CITY OF DENTON STANDARD DETAILS
DRIVEWAY
PROPOSED CONCRETE
FUTURE SIDEWALK
McKINNEY STREET - PHASE 2
FINISHED GRADE.
CAP 4 INCHES ABOVE
OF PAVEMENT. TURN UP AND
TO EXTEND 12" BEYOND EDGE
MIN. 36" BELOW PROP. T.C.
2-6" PVC SCH 40 SLEEVES A
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV08.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV08.dgn1:404:39:41 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLPAVING PLAN & PROFILE
R305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
PBX
585.19
5/8" IRS W/RANDOM
34
BAYLOR UNIVERSITY
4515 E McKINNEY STREET
KENNETH L & GLADYS F STOUT
LOT 151 (PT)
LOT 161
4663 E McKINNEY STREET
MEMORIAL BAPTIST CHURCH OF DENTON
(OLD DCAD 1P, 1P2, 1R), AC
LOT 162, 163, 164
DOC # 99-R0026679
EASEMENT
20' PUBLIC UTILITY
FM
16" W
16" W
8" W
8" WW 8" WW
15" CMP 15" CMP
16" W
119+00 120+00 121+00
5'X2' RCB
24" RCP 24" RCP
5'X2' RCB18"
16" W 16" W
SLEEVES
6" PVC 6" PVC SLEEVES
(+)0.80 %
LT ROW
EX. GROUND AT
TC LT TC 585.30STA 120+29.07CL DRIVETC 585.77STA 120+87.29CL DRIVE584.27PI 119+00.00 584.27584.67585.07585.47585.87586.27585.88586.83584.77585.03587.28587.76584.27584.67585.07585.47585.87586.27119+00 120+00 121+00586.36587.19584.08585.01587.21586.95584.08584.27CONTENT
OPT. MOISTURE
BETWEEN 0 TO +3%
PER ASTM D698
MAX. DENSITY
TO MIN. 95%
COMPACTED FILL
(+)0.80 %
RT ROW
EX. GROUND AT
TC RT584.27PI 119+00.00 590
585
580
590
585
580
590
585
580
590
585
580 MATCHLINE STA 121+50N = 7127057.59
E = 2402844.97
CURVE 6 (CV-6)
DEG = 0° 29' 59.69"
PI STA = 121+05.43
L = 846.81'MATCHLINE STA 121+50 = 4° 14' 00.00" RT
F.L. XXXT.C. XXXCL 10' REC. INLETPAV STA 113+99.92, 39.49' RT
T = 423.60'
R = 11,461.16'
74PROP. TCEX.ROWPROP. TCEX.ROWEX. R.O.W57' (B-B)CL DRIVE
STA 120+29.07 CL DRIVE
STA 120+87.29
SUBGRADE (36 LB/SY PER LIFT) (TYP.)
AND 12" THICK LIME STABILIZED
W/ 9" THICK TYPE B ASPHALT BASE COURSE
3" THICK TYPE C ASPHALT SURFACE COURSE
(TYP.)
CONCRETE DRIVEWAY
8" THICK REINFORCED MATCHLINE STA 119+00MATCHLINE STA 119+0015'RCR 25.50' LT
STA 120+57.32
CR 25.50' LT
STA 121+17.27
& GUTTER
24" CURB
& GUTTER
24" CURB 15'R15'RPATH
12' BIKE/PED
FUTURE
FUTURE 6' SIDEWALK
OFF 60.03' LT
STA 120+80.45
1
5'R
F.L. 580.45
T.C. 584.95
CL 10' REC. INLET
PAV STA 119+85.00, 33.50' RT
F.L. 579.95
T.C. 584.95
CL 20' REC. INLET
PAV STA 119+85.00, 27.50' LT
F.L. 581.19
T.C. 586.19
CL 20' REC. INLET
PAV STA 121+40.00, 27.50' LT
CR 25.50' LT
STA 120+06.54
STREET
CL McKINNEY
CV-6R.O.W.100' R.O.W
EX.
END WORK TO BE DONE BY OTHERS
BEGIN WORK THIS CONTRACT
STA 119+50
McKINNEY STREET
LOT 161
4515 E McKINNEY STREET
KENNETH L & GLADYS F STOUT
(OLD DCAD 1P, 1P2, 1R), AC
LOT 162, 163, 164
4663 E McKINNEY STREET
MEMORIAL BAPTIST CHURCH OF DENTON
OFF 62.65' LT
STA 120+23.05
CR 25.50' LT
STA 120+46.17
A
A
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOLEGEND:
PROPOSED PAVEMENT
NOTES:
FOR ADDITIONAL INFORMATION.
SEE WATER PLAN AND PROFILE SHEETS4.
ADDITIONAL INFORMATION.
SEE PAVING DETAILS SHEET FOR3.
FOR ADDITIONAL INFORMATION.
2. SEE DRAINAGE PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE CITY OF DENTON STANDARD DETAILS
DRIVEWAY
PROPOSED CONCRETE
FUTURE SIDEWALK
McKINNEY STREET - PHASE 2
FINISHED GRADE.
CAP 4 INCHES ABOVE
OF PAVEMENT. TURN UP AND
TO EXTEND 12" BEYOND EDGE
MIN. 36" BELOW PROP. T.C.
2-6" PVC SCH 40 SLEEVES A
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV09.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV09.dgn1:404:39:44 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLPAVING PLAN & PROFILE
R305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
PBX
8" HACKBERRY
DBL. 15"/24" PECAN24" PECAN
27" PECANDBL. 18" ELM
15" PECAN
TRI 12" PECAN
30" PECAN
DBL. 8" TREEDBL. 8"/15" TREE
S
BAYLOR UNIVERSITY
4673 E McKINNEY STREET
MEMORIAL BAPTIST CHURCH OF DENTON
4683 E McKINNEY STREET
SAYR RESOURCES INC
LOT 151 (PT)
LOT 166 LOT 167
(OLD DCAD 1P, 1P2, 1R), AC
LOT 162, 163, 164
4663 E McKINNEY STREET
MEMORIAL BAPTIST CHURCH OF DENTON
BCI REAL ESTATE VENTURES,LP
LOT 151 (PT)
VOL. 5039, PG. 01056
EASEMENT
8' PUBLIC UTILITY
VOL. 5039, PG. 01056
EASEMENTCONSTRUCTION
20' TEMPORARY
VOL. 5039, PG. 01056
EASEMENT
20' PUBLIC UTILITY
WV
WV 16" W 16" W
8" W
8" W
8" WW 8" WW 8" WW
18" CMP 15" RCP 15" RCP
PT 125+28.65122+00 123+00 124+00 125+00 126+00
16" W16" W 16" W 16" W
6" PVC SLEEVES
6" PVC SLEEVES586.67586.93587.19587.44587.70587.92587.89587.66587.42588.33588.23588.61588.16588.29587.98588.31588.36588.16586.27587.76(+)0.80 %(+)0.52 %
(+)0.52 %(-)0.50 %
100' VC 587.81VPT 125+20.00587.81VPC 124+20.00LT ROW
EX. GROUND AT
TC LTTC 586.64STA 121+96.22CL DRIVETC 587.94CREST 124+70.82E = -0.12'
K = 98.4
(-)0.50%
100' VC
E = -0.12'
K = 98.4
(-)0.50%586.67PI 122+00.00TC 587.94(588.06)PI 124+70.00 586.67586.93587.19587.44587.70587.92587.89587.66587.42122+00 123+00 124+00 125+00 126+00585.73585.89585.96585.85585.74585.52586.59586.30586.89586.27586.95587.42585.52100' VC
E = -0.13'
K = 98
CONTENT
OPT. MOISTURE
BETWEEN 0 TO +3%
PER ASTM D698
MAX. DENSITY
TO MIN. 95%
COMPACTED FILL
(+)0.80 %(+)0.52 %587.81VPC 124+20.00587.81VPT 125+20.00TC RT TC 587.94CREST 124+70.82(+)0.52 %(-)0.50 %586.67PI 122+00.00TC 587.94(588.06)PI 124+70.00 RT ROW
EX. GROUND AT
5'X2' RCB 36" RCPRCB
5'X3'
McKINNEY STREET
590
585
595
590
585
595
PROP. TCEX.ROWPROP. TCEX.ROW590
585
595
590
585
595
MATCHLINE STA 121+50N = 7127057.59
E = 2402844.97
CURVE 6 (CV-6)
DEG = 0° 29' 59.69"
PI STA = 121+05.43
L = 846.81'MATCHLINE STA 121+50 = 4° 14' 00.00" RT
T = 423.60'
R = 11,461.16'
CV-6
MATCHLINE STA 126+0075MATCHLINE STA 126+00432.96'
S 71° 32' 05.00" ECL McKINNEY STREET
CONCRETE DRIVEWAY
8" THICK REINFORCED
CL DRIVEWAY
STA 121+92.22
EX. R.O.W
EX. R.O.W
EX. WIRE FENCE100' R.O.W.57' (B-B)SUBGRADE (36 LB/SY PER LIFT) (TYP.)
AND 12" THICK LIME STABILIZED
W/ 9" THICK TYPE B ASPHALT BASE COURSE
3" THICK TYPE C ASPHALT SURFACE COURSE
2
0'RCR 25.50' LT
STA 121+64.72
CR 25.50' LT
STA 122+26.50
& GUTTER
24" CURB
& GUTTER
24" CURB
PATH
12' BIKE/PED
FUTURE
6' SIDEWALK
FUTURE
CR 58.38' LT
STA 121+96.22
F.L. 580.97
TH 587.47
TOP 588.47
4'x4' SQUARE DROP INLET
59.50' LT
PAV STA 122+95.00,
5'R
15'R5'R
A
A
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOLEGEND:
PROPOSED PAVEMENT
NOTES:
FOR ADDITIONAL INFORMATION.
SEE WATER PLAN AND PROFILE SHEETS4.
ADDITIONAL INFORMATION.
SEE PAVING DETAILS SHEET FOR3.
FOR ADDITIONAL INFORMATION.
2. SEE DRAINAGE PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE CITY OF DENTON STANDARD DETAILS
DRIVEWAY
PROPOSED CONCRETE
FUTURE SIDEWALK
McKINNEY STREET - PHASE 2
FINISHED GRADE.
CAP 4 INCHES ABOVE
OF PAVEMENT. TURN UP AND
TO EXTEND 12" BEYOND EDGE
MIN. 36" BELOW PROP. T.C.
2-6" PVC SCH 40 SLEEVES A
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV10.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV10.dgn1:404:39:46 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLPAVING PLAN & PROFILE
R305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PBX
36" TREE
36" PECAN
2" TREE
36" PECAN
2" TREE
48" PECAN
DBL. 4"/15" HACKBERRY
6" HACKBERRY
21" CEDARDBL. 15"/24" PECAN
S
586.97
5/8" IRS W/RANDOM
35
BCI REAL ESTATE VENTURES,LP
5001 E McKINNEY STREET
BARBARA McDONALD COBB
LOT 151 (PT)
LOT 168 LOT 169
5043 E McKINNEY STREET
CHELA DARLINE McDONALD
VOL. 5039, PG. 01056
EASEMENTCONSTRUCTION
20' TEMPORARY
VOL. 5039, PG. 01056
EASEMENT
20' PUBLIC UTILITY DOC
#
9
9
-R00773
0
9
2
0' PUBLI
C UTI
LI
TY EASEMENTSTREET
5043 E McKINNEY
McDONALD
CHELA DARLINE
VOL. 5039, PG. 01056
EASEMENT
8' PUBLIC UTILITY
FM
16" W 16" W
8" WW
8
"
WW6" W
6
" W6
" W8" W
15" RCP
15" RCP
21" RCP 21" RCP 21" RCP
PC 129+61.61126+00 127+00 128+00 129+00 130+00
16" W 16" W 16" W 16" W 16" W
SLEEVES
6" PVC
SLEEVES
6" PVC
SLEEVES
6" PVC
SLEEVES
6" PVC
SLEEVES
6" PVC 587.18587.24586.99586.74586.49586.24585.99587.47587.37587.58587.28587.36587.38587.15587.20587.98587.42578.29587.42587.18587.29587.24586.99586.74586.49586.24585.99126+00 127+00 128+00 129+00 130+00585.05584.74585.52585.32585.71586.24584.58585.07585.96587.42585.52585.99585.96(-)0.50 %
LT ROW
EX. GROUND AT
TC LTTC 587.21STA 126+41.32CL DRIVETC 586.90STA 128+17.95CL DRIVETC 586.47STA 129+03.63CL DRIVETC 586.13STA 129+72.82CL DRIVE587.23VPC 126+37.50(-)0.50%(+)0.50%587.23VPT 126+87.50587.27VPC 126+95.00E = -0.07'
K = 50
50' VC 587.27VPT 127+45.00(+)0.50%
E = -0.06'
K = 50
50' VC
(-)0.50 %TC 587.17SAG (587.10)PI 126+62.50TC 587.33CREST (587.39)PI 127+20.00 CONTENT
OPT. MOISTURE
BETWEEN 0 TO +3%
PER ASTM D698
MAX. DENSITY
TO MIN. 95%
COMPACTED FILL
RT ROW
EX. GROUND AT TC RTTC 587.22STA 126+85.55CL DRIVE587.23VPC 126+37.50(-)0.50 %587.23VPT 126+87.50(+)0.50 %587.26VPC 126+95.00(+)0.50 %(-)0.50 %587.26VPT 127+45.00E = -0.06'
K = 50
50' VC
E = -0.06'
K = 50
50' VCTC 587.18SAG (587.10)PI 126+62.50 TC 587.33CREST (587.39)PI 127+20.00D
18" RCP18" RCP36"
R
C
P
18" RCP
36" RCP
36" RCP18"18" RCPD
36" RCP
RCP
24"
4'x3' RCB
590
585
580
590
585
580PROP. TCEX.ROWPROP. TCEX.ROW590
585
580
590
585
580 MATCHLINE STA 126+00N = 7126786.29
E = 2403657.43
CURVE 7 (CV-7)
DEG = 0° 55' 00.24"
PI STA = 134+97.42
= 9° 48' 00.00" RT
CL DRIVEWAY
STA 126+85.55
T = 535.81'
R = 6,250.00'
CV-7
MATCHLINE STA 126+0076MATCHLINE STA 130+00MATCHLINE STA 130+00432.96'
S 71° 32' 05.00" E
L = 1,069.01'
CL McKINNEY STREET
F.L. 582.67
T.C. 587.17
CL 10' REC. INLET
PAV STA 126+70.37, 27.50' LT
F.L. 582.67
T.C. 587.17
CL 10' REC. INLET
PAV STA 126+54.63, 33.50' RT
R.O.W
EX.
EX. R.O.W
FENCE
EX. WIRE
CL DRIVEWAY
STA 126+41.32
CL DRIVEWAY
STA 128+17.95 CL DRIVEWAY
STA 129+03.63
CL DRIVEWAY
STA 129+72.82
R.O.WEX. 100' R.O.W.57' (B-B)SUBGRADE (36 LB/SY PER LIFT) (TYP.)
AND 12" THICK LIME STABILIZED
W/ 9" THICK TYPE B ASPHALT BASE COURSE
3" THICK TYPE C ASPHALT SURFACE COURSE
1
0'R10'R25'
R 25'R
10'R10'RCR 25.50' LT
STA 126+24.95
CR 25.50' LT
STA 126+54.87
CR 31.50' RT
STA 126+70.13
CR 31.50' RT
STA 127+01.72
10.8'
CR 25.50' LT
STA 127+91.48
CR 25.50' LT
STA 128+42.48
9.1'
CR 25.50' LT
STA 128+89.27
CR 25.50' LT
STA 129+22.47
CR 25.50' LT
STA 129+53.80
CR 25.50' LT
STA 129+95.70
& GUTTER
24" CURB 20'R15'R
10'R10'R10'RROADCARPENTER N.
OFF 52.64' LT
STA 129+62.76
OFF 54.16' LT
STA 129+64.74
16.9'GRAVEL DRIVEWAY
MATCH EX.
6' SIDEWALK
FUTURE
& GUTTER
24" CURB
BIKE/PED PATH
FUTURE 12'F.L. 580.36
TH 586.36
TOP 587.36
CONSTRUCT 5'X5' DROP INLET
PAV STA 127+50.00, 57.50' LT
F.L. 581.80
T.C. 586.30
CL 10' REC. INLET
27.50' LT
PAV STA 129+38.50,
F.L. 581.67
T.C. 586.67
CL 10' REC. INLET
27.50' LT
PAV STA 128+65.00,
OFF 50.00' LT
STA 129+11.37
FENCE
POST
STEEL
EX.
F.L. 580.94
TOP 586.94, TH 585.94
2'x2' DROP INLET
35.50' LT
PAV STA 128+50.00,
STREET
McKINNEY
1
0'
R
A
A
A A A
TYPE 1A RAMP
CITY OF DENTON
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOLEGEND:
PROPOSED PAVEMENT
NOTES:
FOR ADDITIONAL INFORMATION.
SEE WATER PLAN AND PROFILE SHEETS4.
ADDITIONAL INFORMATION.
SEE PAVING DETAILS SHEET FOR3.
FOR ADDITIONAL INFORMATION.
2. SEE DRAINAGE PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE CITY OF DENTON STANDARD DETAILS
DRIVEWAY
PROPOSED CONCRETE
FUTURE SIDEWALK
McKINNEY STREET - PHASE 2
FINISHED GRADE.
CAP 4 INCHES ABOVE
OF PAVEMENT. TURN UP AND
TO EXTEND 12" BEYOND EDGE
MIN. 36" BELOW PROP. T.C.
2-6" PVC SCH 40 SLEEVES A
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV11.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV11.dgn1:404:39:49 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLPAVING PLAN & PROFILE
R305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
CONCRETE
PBX
E
5101 E McKINNEY STREET
DENTON ISD
5090 E McKINNEY STREET
EDIBERTO A RODRIGUEZ
LOT 1R4
LOT 150
BCI REAL ESTATE VENTURES,LP
LOT 151 (PT)
E McKINNEY STREET
KIM Y PHAM
LOT 1
CAB. H, PG. 62
20' UTILITY EASEMENT
CAB. E, PG. 330
4' SIDEWALK EASEMENT
LOT 169
STREET
5043 E McKINNEY
McDONALD
CHELA DARLINE
WV
WV
WVFM
16" W 16" W
16" W
8" W
8" W 8" W10" W10" W
10" W
24" RCP
27" RCP
15"
R
C
P
24"
R
C
P
27" RCP 27" RCP
2-48" RCP24"
R
CPRCBCEX.9'X6'PTZ
130+00 131+00 132+00 133+00 134+00
135+00
16" W 16" W 16" W
16" W
1
0
" W6" PVC SLEEVES
6" PVC SLEEVES
585.74585.49585.24584.99584.74584.49
584.47584.82585.55586.43583.27584.25584.08578.56 585.72587.33585.19584.96587.56585.66585.99587.20
CONTENT
OPT. MOISTURE
BETWEEN 0 TO +3%
PER ASTM D698
MAX. DENSITY
TO MIN. 95%
COMPACTED FILL
150' VC
LT ROW
EX. GROUND AT
TC LT 584.52VPC 132+95.00585.46VPT 134+45.00 TC 584.43SAG 133+28.17(-)0.50 %(-)0.50 %
E = 0.42'
K = 66.3
(+)1.76 %
(+)1.76 %
PROP. 3-6'X3' RCB TC 584.56(584.14)PI 133+70.00RYAN WAY585.99585.74585.49585.24584.99584.74584.49
584.47584.82585.55586.43130+00 131+00 132+00 133+00 134+00 135+00583.19584.05583.33579.43 584.77586.23585.96584.85584.16586.05585.82585.99585.96586.43586.23
CONTENT
OPT. MOISTURE
BETWEEN 0 TO +3%
PER ASTM D698
MAX. DENSITY
TO MIN. 95%
COMPACTED FILL
(-)0.50 %(+)1.76 %585.46VPT 134+45.00 150' VC584.51VPC 132+95.00RT ROW
EX. GROUND AT
TC RT
TC 584.65STA 132+67.33CL DRIVETC 584.43SAG 133+28.17E = 0.42'
K = 66.3
(-)0.50 %
PROP. 3-6'X3' RCB TC 584.56(584.14)PI 133+70.00BOX CULVERT3-6'x3'D18"
30" RCP 24" RCP18"18" RCP36" RCP36" RCP36" RCP24" RCP24"24"18"RCB
5'X3'
18" RCP
4'X3' RCB
4'X3' RCB
McKINNEY STREET
590
585
580
590
585
580
PROP. TCEX.ROWPROP. TCEX.ROW590
585
580
590
585
580 MATCHLINE STA 130+00N = 7126786.29
E = 2403657.43
CURVE 7 (CV-7)
DEG = 0° 55' 00.24"
PI STA = 134+97.42
= 9° 48' 00.00" RT
T = 535.81'
R = 6,250.00'
CV-7
77MATCHLINE STA 135+00MATCHLINE STA 130+00L = 1,069.01'MATCHLINE STA 135+00RYAN WAYCL McKINNEY STREET
F.L. 581.24
T.C. 585.74
CL 10' REC. INLET
PAV STA 130+50.00, 33.50' RT
F.L. 579.94
T.C. 584.44
CL 10' REC. INLET
PAV STA 133+35.00, 33.50' RT
F.L. 581.05
T.C. 585.55
CL 10' REC. INLET
PAV STA 134+50.00, 33.50' RT
SUBGRADE (36 LB/SY PER LIFT) (TYP.)
AND 12" THICK LIME STABILIZED
W/ 9" THICK TYPE B ASPHALT BASE COURSE
3" THICK TYPE C ASPHALT SURFACE COURSE
R.O.WEX.
EX. R.O.W
EX. R.O.W
CL DRIVEWAY
STA 132+67.33
100' R.O.W.EX. GUARDRAIL
FENCE
EX. WOOD
FENCE
EX. IRON
EX. GUARDRAIL
FENCE
EX. IRON 57' (B-B)CONCRETE DRIVEWAY
8" THICK REINFORCED
25'R30'RCR 25.50' LT
STA 130+78.35
CR 25.50' LT
STA 132+02.02
29.5'
CR 31.50' RT
STA 132+37.32
CR 31.50' RT
STA 132+97.33
& GUTTER
24" CURB
& GUTTER
24" CURB
PATH
12' BIKE/PED
FUTURE
15'R1
5'R
84
PAVING PLAN AND PROFILE
RYAN WAY
SEE SH. FOR
F.L. 579.94
T.C. 584.44
CL 15' REC. INLET
STA 133+37.50, 27.50' LT
F.L. 580.81
TH 585.81
TOP 586.81
DROP INLET
CONSTRUCT 4'X4'
42.00' LT
PAV STA 130+70.00,
SIDEWALK
FUTURE 6'
F.L. 580.46
T.C. 584.96
CL 10' REC. INLET
PAV STA 132+05.00, 33.50' RT
A
A
CL RYAN WAY
STA 131+47.51
TYPE 1A RAMP
CITY OF DENTON
TYPE 1A RAMP
CITY OF DENTON
TYPE 1A RAMP
CITY OF DENTON
F.L. 580.74
T.C. 585.74
CL 10' REC. INLET
27.50' LT
PAV STA 130+50.00,
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOLEGEND:
PROPOSED PAVEMENT
NOTES:
FOR ADDITIONAL INFORMATION.
SEE WATER PLAN AND PROFILE SHEETS4.
ADDITIONAL INFORMATION.
SEE PAVING DETAILS SHEET FOR3.
FOR ADDITIONAL INFORMATION.
2. SEE DRAINAGE PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE CITY OF DENTON STANDARD DETAILS
DRIVEWAY
PROPOSED CONCRETE
FUTURE SIDEWALK
McKINNEY STREET - PHASE 2
FINISHED GRADE.
CAP 4 INCHES ABOVE
OF PAVEMENT. TURN UP AND
TO EXTEND 12" BEYOND EDGE
MIN. 36" BELOW PROP. T.C.
2-6" PVC SCH 40 SLEEVES A
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV12.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV12.dgn1:404:39:51 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLPAVING PLAN & PROFILE
R305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
E
587.02
5/8" IRS W/RANDOM36
5101 E McKINNEY STREET
DENTON ISD
E McKINNEY STREET
KIM Y PHAM
LOT 1R4
LOT 1
CAB. H, PG. 62
20' UTILITY EASEMENT
CAB. E, PG. 330
4' SIDEWALK EASEMENT
WV
10" W 10" W
16" W
16" W
16" W
24" RCP
135+00 136+00 137+00 138+00 139+00
16" W 16" W 16" W
6" PVC SLEEVES
587.31588.19588.82589.20589.58589.96590.34590.72592.52592.77591.39592.08592.71589.37590.63589.08586.43587.33LT ROW
EX. GROUND AT
TC LT(+)1.76 %
(+)0.76 %588.63PI 136+25.00TC 587.99STA 135+88.61CL DRIVE586.43587.31588.19588.82589.20589.58589.96590.34590.72135+00 136+00 137+00 138+00 139+00591.83591.90590.77591.43591.39589.53590.27586.23588.21586.43586.23590.72591.39RT ROW
EX. GROUND AT
TC RT
(+)1.76 %588.63PI 136+25.00(+)0.76 %
18" RCP
24" RCP
18" RCP
McKINNEY STREET
PROP. TCEX.ROWPROP. TCEX.ROW595
590
585
MATCHLINE STA 135+00N = 7126786.29
E = 2403657.43
CURVE 7 (CV-7)
DEG = 0° 55' 00.24"
PI STA = 134+97.42
= 9° 48' 00.00" RT
T = 535.81'
R = 6,250.00'
CV-7
78MATCHLINE STA 139+00L = 1,069.01'MATCHLINE STA 135+00MATCHLINE STA 139+00F.L. 584.70
T.C. 589.20
CL 10' REC. INLET
PAV STA 137+00.00, 27.50' LT
CL McKINNEY STREET
CL DRIVEWAY
STA 135+88.61
R.O.WEX.
EX. R.O.W
SUBGRADE (36 LB/SY PER LIFT) (TYP.)
AND 12" THICK LIME STABILIZED
W/ 9" THICK TYPE B ASPHALT BASE COURSE
3" THICK TYPE C ASPHALT SURFACE COURSE
CONCRETE DRIVEWAY
8" THICK REINFORCED 57' (B-B)57' (B-B)100' R.O.W.595
590
585
595
590
585
595
590
585
35'R35'R
CR 25.50' LT
STA 135+39.13
CR 25.50' LT
STA 136+37.90
& GUTTER
24" CURB
& GUTTER
24" CURB
OFF 84.45' LT
STA 135+88.61
PATH
12' BIKE/PED
FUTURE
FUTURE 6' SIDEWALK
F.L. 581.93
T.C. 586.43
CL 10' REC. INLET
PAV STA 135+00.00, 27.50' LT
A
TYPE 1A RAMP
CITY OF DENTON
TYPE 1A RAMP
CITY OF DENTON
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOLEGEND:
PROPOSED PAVEMENT
NOTES:
FOR ADDITIONAL INFORMATION.
SEE WATER PLAN AND PROFILE SHEETS4.
ADDITIONAL INFORMATION.
SEE PAVING DETAILS SHEET FOR3.
FOR ADDITIONAL INFORMATION.
2. SEE DRAINAGE PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE CITY OF DENTON STANDARD DETAILS
DRIVEWAY
PROPOSED CONCRETE
FUTURE SIDEWALK
McKINNEY STREET - PHASE 2
FINISHED GRADE.
CAP 4 INCHES ABOVE
OF PAVEMENT. TURN UP AND
TO EXTEND 12" BEYOND EDGE
MIN. 36" BELOW PROP. T.C.
2-6" PVC SCH 40 SLEEVES A
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV13.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV13.dgn1:404:39:54 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLPAVING PLAN & PROFILE
R305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
V
E
ES
592.87
5/8" IRS W/RANDOM
37
5101 E McKINNEY STREET
DENTON ISD
E McKINNEY STREET
KIM Y PHAM
E McKINNEY STREET
KIM Y PHAM
LOT 1R4
LOT 1, BLOCK A LOT 1, BLOCK B
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
LOT 1
CAB. H, PG. 62
20' UTILITY EASEMENT
CAB. H, PG. 62
16' UTILITY EASEMENT
CAB. E, PG. 60
16' UTILITY EASEMENT
C
AB. H,
P
G.
6
2
1
6'
U
TI
LI
T
Y
E
AS
E
ME
NT
CAB. E, PG. 330
EASEMENT
4' SIDEWALK
CAB. E, PG. 330
4' SIDEWALK EASEMENT
WV WV
WVWV
WV
WV
WVWV
FM
10" W 10" W
16" W 16" W 16" W 16" W16" W8" W8" W10" WW
10" WW
10" WW10"WW16" W
(
F
O
R
C
E MAI
N)
8" WW8" WW8" W PT 140+30.62139+00 140+00 141+00 142+00 143+00
16" W 16" W 16" W 16" W16 " W16" W16" W 16" W
16" W
6" PVC SLEEVES
SLEEVES
6" PVC 6" PVC SLEEVES591.10591.48591.86592.24592.62592.99593.11592.85592.21593.32593.52592.72593.07592.64592.42592.40592.39592.40590.72592.71(+)0.76 %(-)2.56 %LT ROW
EX. GROUND AT
TC LT
592.92VPC 141+90.00 E = -0.91'
K = 66
220' VC
TC 592.85
(593.76)
PI 143+00.00
TC 593.02
STA 142+04.57
CL DRIVE
TC 593.12
CREST 142+40.36
(+)0.76 %590.72591.10591.48591.86592.24592.62592.99593.11592.85592.21139+00 140+00 141+00 142+00 143+00590.75590.47590.69590.78590.39591.39589.81589.78590.47589.46590.72591.39CONTENT
OPT. MOISTURE
BETWEEN 0 TO +3%
PER ASTM D698
MAX. DENSITY
TO MIN. 95%
COMPACTED FILL
TC RT (+)0.76 %(-)2.56 %
RT ROW
EX. GROUND AT GLENNGARY WAY592.92VPC 141+90.00 E = -0.91'
K = 66
220' VC
TC 592.85
(593.76)
PI 143+00.00
TC 593.12
CREST 142+40.36
(+)0.76 %
D18"24" RCP
18"RCP
McKINNEY STREET
PROP. TCEX.ROWPROP. TCEX.ROW590
585
595
590
585
595
MATCHLINE STA 139+00N = 7126786.29
E = 2403657.43
CURVE 7 (CV-7)
DEG = 0° 55' 00.24"
PI STA = 134+97.42
= 9° 48' 00.00" RT
T = 535.81'
R = 6,250.00'
CV-7
79MATCHLINE STA 143+50L = 1,069.01'MATCHLINE STA 139+00MATCHLINE STA 143+50WAYGLENNGARY
1,216.03'
S 61° 44' 05.00" E
OFF 84.71' RT
STA 139+84.20
OFF 50.96' LT
STA 142+00.03
CL McKINNEY STREET
57' (B-B)100' R.O.W.CL DRIVEWAY
STA 142+04.57
CL GLENNGARY WAY
STA 139+78.36
F.L. 586.30
T.C. 590.80
CL 10' REC. INLET
PAV STA 139+10.00, 27.50' LT
R.O.WEX. R.O.W
EX.
R.O.WEX.
SUBGRADE (36 LB/SY PER LIFT) (TYP.)
AND 12" THICK LIME STABILIZED
W/ 9" THICK TYPE B ASPHALT BASE COURSE
3" THICK TYPE C ASPHALT SURFACE COURSE
FENCE
EX. WOOD
FENCE
EX. WOOD
590
585
595
590
585
595
30'R 20'R20'RCR 31.50' RT
STA 139+26.94
CR 31.50' RT
STA 140+33.38
CR 25.50' LT
STA 141+71.70
CR 25.50' LT
STA 142+33.16
& GUTTER
24" CURB
& GUTTER
24" CURB
6' SIDEWALK
FUTURE
PATH
12' BIKE/PED
FUTURE
F.L. 587.85
T.C. 592.35
CL 10' REC. INLET
PAV STA 141+15.00, 27.50' LT
30'R
F.L. 587.36
T.C. 591.86
CL 10' REC. INLET
PAV STA 140+50.00, 33.50' RT
SIDEWALK
FUTURE 6'
A
A
CONCRETE DRIVEWAY
8" THICK REINFORCED
A
TYPE 1A RAMP
CITY OF DENTON
TYPE 1A RAMP
CITY OF DENTON
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOLEGEND:
PROPOSED PAVEMENT
NOTES:
FOR ADDITIONAL INFORMATION.
SEE WATER PLAN AND PROFILE SHEETS4.
ADDITIONAL INFORMATION.
SEE PAVING DETAILS SHEET FOR3.
FOR ADDITIONAL INFORMATION.
2. SEE DRAINAGE PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE CITY OF DENTON STANDARD DETAILS
DRIVEWAY
PROPOSED CONCRETE
FUTURE SIDEWALK
McKINNEY STREET - PHASE 2
FINISHED GRADE.
CAP 4 INCHES ABOVE
OF PAVEMENT. TURN UP AND
TO EXTEND 12" BEYOND EDGE
MIN. 36" BELOW PROP. T.C.
2-6" PVC SCH 40 SLEEVES A
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV14.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV14.dgn1:404:39:56 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLPAVING PLAN & PROFILE
R305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
S
E McKINNEY STREET
KIM Y PHAM
E McKINNEY STREET
ATMOS ENERGY CORP
LOT 1
LOT 147B
LOT 1, BLOCK B
CAB. E, PG. 60
16' UTILITY EASEMENT
CAB. E, PG. 330
EASEMENT
4' SIDEWALK
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
FM
T
16" W 16" W 16" W
8" WW 8" WW 8" WW
18" RCP
8" WW6" WW144+00 145+00 146+00 147+00 148+00
16" W 16" W 16" W 16" W
SLEEVES
6" PVC 591.19589.92588.65587.62586.90586.47586.12585.76585.41588.89587.84591.61590.06586.32585.89586.97586.69585.13592.21592.64CONTENT
OPT. MOISTURE
BETWEEN 0 TO +3%
PER ASTM D698
MAX. DENSITY
TO MIN. 95%
COMPACTED FILL
(-)2.56 %(-)0.71 %
LT ROW
EX. GROUND AT
TC LT590.94VPT 144+10.00 220' VC
E = -0.91'
K = 66 586.58VPT 146+35.00 589.02VPC 144+85.00 150' VC
E = 0.35'
K = 81
TC 587.45
(587.10)
PI 145+60.00
591.19589.92588.65587.62586.90586.47586.12585.76585.41144+00 145+00 146+00 147+00 148+00587.04585.53590.02588.68583.39582.81584.68583.96582.44592.21590.39585.41582.44CONTENT
OPT. MOISTURE
BETWEEN 0 TO +3%
PER ASTM D698
MAX. DENSITY
TO MIN. 95%
COMPACTED FILL
(-)2.56 %(-)0.71 %586.58VPT 146+35.00 150' VC
E = 0.35'
K = 81
589.02VPC 144+85.00 RT ROW
EX. GROUND AT
TC RT
220' VC
E = -0.91'
K = 66 590.94VPT 144+10.00 TC 587.45
(587.10)
PI 145+60.00
TC 590.71STA 144+18.85CL DRIVED18"RCP18"18" RCP
McKINNEY STREET
PROP. TCEX.ROWPROP. TCEX.ROW595
590
585
MATCHLINE STA 143+5080MATCHLINE STA 148+00MATCHLINE STA 143+501,216.03'
S 61° 44' 05.00" E
MATCHLINE STA 148+00F.L. 582.19
T.C. 586.69
CL 10' REC. INLET
PAV STA 146+20.00, 33.50' RT
CL DRIVEWAY
STA 144+18.85
CL McKINNEY STREET
100' R.O.W.57' (B-B)R.O.WEX.
EX. R.O.W
SUBGRADE (36 LB/SY PER LIFT) (TYP.)
AND 12" THICK LIME STABILIZED
W/ 9" THICK TYPE B ASPHALT BASE COURSE
3" THICK TYPE C ASPHALT SURFACE COURSE
CONCRETE DRIVEWAY
8" THICK REINFORCED
FENCE
EX. WOOD
LINK FENCE
EX. CHAIN
LINK FENCE
EX. CHAIN
595
590
585
595
590
585
595
590
585
CR 31.50' RT
STA 143+97.06
CR 31.50' RT
STA 144+40.64
12'
& GUTTER
24" CURB
& GUTTER
24" CURB
PATH
12' BIKE/PED
FUTURE
6' SIDEWALK
FUTURE
F.L. 583.12
T.C. 587.62
CL 10' REC. INLET
PAV STA 145+50.00, 27.50' LT
1
5'RA15'R
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOLEGEND:
PROPOSED PAVEMENT
NOTES:
FOR ADDITIONAL INFORMATION.
SEE WATER PLAN AND PROFILE SHEETS4.
ADDITIONAL INFORMATION.
SEE PAVING DETAILS SHEET FOR3.
FOR ADDITIONAL INFORMATION.
2. SEE DRAINAGE PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE CITY OF DENTON STANDARD DETAILS
DRIVEWAY
PROPOSED CONCRETE
FUTURE SIDEWALK
McKINNEY STREET - PHASE 2
FINISHED GRADE.
CAP 4 INCHES ABOVE
OF PAVEMENT. TURN UP AND
TO EXTEND 12" BEYOND EDGE
MIN. 36" BELOW PROP. T.C.
2-6" PVC SCH 40 SLEEVES A
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV15.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV15.dgn1:404:39:59 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLPAVING PLAN & PROFILE
R305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
CONCRETE E
S S
S
582.48
X CUT SET
38
E McKINNEY STREET
ATMOS ENERGY CORP
LOT 147B
CAB. E, PG. 60
16' UTILITY EASEMENT
CAB. E, PG. 60
16' UTILITY EASEMENT
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
LOT 1 LOT 1
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
WV
WV
FMFM
16" W
16" W
8" WW 8" WW
12" WW12" W W
8" WW 8" WW
16" W
18" RCP BOX CULVERT4.35'x4'3-
3
6
" CMP
8" WW 6" WW8" WW
RCBEX.3-6'x3' PC 152+46.66148+00 149+00 150+00 151+00 152+00
16" W 16" W 16" W
16" W
6" PVC SLEEVES
12" WW585.06584.71584.35584.00582.57582.29583.13582.05581.61584.11583.12584.67584.36585.41585.13583.75583.50583.25583.00582.78
CONTENT
OPT. MOISTURE
BETWEEN 0 TO +3%
PER ASTM D698
MAX. DENSITY
TO MIN. 95%
COMPACTED FILL
LT ROW
EX. GROUND AT
TC LT 582.83VPC 152+35.00 S FORK DRIVE(-)0.71 %(-)0.50 %584.00PI 150+00.00 (-)0.50 %
50'VC
E=0.07'
K=47
PROP. 3-7'X3' RCB
585.41585.06584.71584.35148+00 149+00 150+00 151+00 152+00579.24578.10580.80580.11579.41582.44581.74581.45582.18581.90585.41582.44584.00583.75583.50583.25583.00582.78
CONTENT
OPT. MOISTURE
BETWEEN 0 TO +3%
PER ASTM D698
MAX. DENSITY
TO MIN. 95%
COMPACTED FILL
TC RT
AT RT ROW
EX. GROUND
(-)0.71 %(-)0.50 %582.83VPC 152+35.00 (-)0.50 %584.00PI 150+00.00 50'VC
E=0.07'
K=47
PROP. 3-7'X3' RCB
SHALLOW PIPE
18" RCP 18" RCP18"24" RCP 24" RCP 18" RCP24" RCP24" RCP18" RCPCULVERTBOX 3-7'x3'590
585
580
590
585
580
PROP. TCEX.ROWPROP. TCEX.ROW590
585
580
590
585
580 MATCHLINE STA 148+0081MATCHLINE STA 152+501,216.03'
S 61° 44' 05.00" E
MATCHLINE STA 148+00MATCHLINE STA 152+50S FORK DRIVEN = 7125695.37
E = 2405879.01
CURVE 8 (CV-8)
DEG = 2° 30' 00.00"
PI STA = 154+40.11
= 9° 39' 00.00" RT
T = 193.46'
R = 2,291.83'
CV-8
L = 386.00'
OFF 63.76' LT
STA 150+23.45
CL S FORK DRIVE
STA 150+23.45100' R.O.W.57' (B-B)R.O.WEX.
R.O.WEX.
R.O.WEX.
F.L. 579.85
T.C. 584.35
CL 10' REC. INLET
PAV STA 149+50.00, 33.50' LT
SUBGRADE (36 LB/SY PER LIFT) (TYP.)
AND 12" THICK LIME STABILIZED
W/ 9" THICK TYPE B ASPHALT BASE COURSE
3" THICK TYPE C ASPHALT SURFACE COURSE
EX. WOOD FENCE
FENCE
EX. CHAIN LINK
EX. WOOD FENCE
FENCE
EX. WOOD
POND
EX. DETENTION
POND
EX. DETENTION
3
0'RCR 25.50' LT
STA 149+68.89
CR 25.50' LT
STA 150+77.91
& GUTTER
24" CURB
FUTURE 6' SIDEWALK
& GUTTER
24" CURB BOXES
SHALLOW
F.L. 580.42
T.C. 584.92
CL 10' REC. INLET
27.50' LT
PAV STA 148+70.00,
STREET
CL McKINNEY
CONCRETE STREET HEADER
INSTALL 109 LF REINFORCED
BEGIN CONCRETE PAVEMENT
END ASPHALT PAVEMENT
W/ 8% LIME (48 LB/SY) (TYP.)
8" THICK STABILIZED SUBGRADE
W/ #4 BARS @ 18" O.C. EACH WAY
4000 PSI COMPRESSIVE STRENGTH
8" THICK REINF. CONC. PAVEMENT,
PATHBIKE/PED
FUTURE 12'
SEE PAVING DETAILS
LONGITUDINAL BUTT JOINT
INSTALL 58 LF
30'RPVMT SECTION
MATCH EX.
McKINNEY STREET
A
F.L. 578.57
T.C. 583.07
CL 10' STD. INLET
PAV STA 150+47.92, 60.50' LT
F.L. 578.94
T.C. 583.94
CL 10' STD. INLET
PAV STA 149+98.96, 62.32' LT
TYPE 1A RAMP
CITY OF DENTON
TYPE 1A RAMP
CITY OF DENTON
WALL
EX. BRICK
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOLEGEND:
PROPOSED PAVEMENT
NOTES:
FOR ADDITIONAL INFORMATION.
SEE WATER PLAN AND PROFILE SHEETS4.
ADDITIONAL INFORMATION.
SEE PAVING DETAILS SHEET FOR3.
FOR ADDITIONAL INFORMATION.
2. SEE DRAINAGE PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE CITY OF DENTON STANDARD DETAILS
DRIVEWAY
PROPOSED CONCRETE
FUTURE SIDEWALK
McKINNEY STREET - PHASE 2
FINISHED GRADE.
CAP 4 INCHES ABOVE
OF PAVEMENT. TURN UP AND
TO EXTEND 12" BEYOND EDGE
MIN. 36" BELOW PROP. T.C.
2-6" PVC SCH 40 SLEEVES A
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV16.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV16.dgn1:404:40:02 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLPAVING PLAN & PROFILE
R305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
S
E McKINNEY STREET
ATMOS ENERGY CORP
LOT 147A
E McKINNEY STREET
ATMOS ENERGY CORP
LOT 147B
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
LOT 1
CAB. E, PG. 60
16' UTILITY EASEMENT
FM
8" WW
16" W
16" W
8" WW
8" WW
3'x2' RCB
3'x2' RCB PC 152+46.66 PT 156+32.66153+00
154+00 155+00 156+00
157+00
16" W
16" W
16" W
16" W
581.94581.40581.69581.61583.78582.93583.21583.50583.78582.78CONTENT
OPT. MOISTURE
BETWEEN 0 TO +3%
PER ASTM D698
MAX. DENSITY
TO MIN. 95%
COMPACTED FILL
LT ROW
EX. GROUND AT
TC LT
EX.(+)0.58 %
T.P. 583.28
T.C. 583.78
MATCH EX. PVM'T.
154+50.00, 27.80' LT
EX. TC
(+)0.57 %582.84VPT 152+85.00 (-)0.50 %
(+)0.57 %TC 582.77SAG 152+58.41E=0.07'
K=47
50'VC
E=0.07'
K=47
TC 582.77(582.70)PI 152+60.00153+00 154+00 155+00 156+00 157+00580.51579.99579.81579.41583.78582.93583.21583.50583.78582.78CONTENT
OPT. MOISTURE
BETWEEN 0 TO +3%
PER ASTM D698
MAX. DENSITY
TO MIN. 95%
COMPACTED FILL
TC RT
AT RT ROW
EX. GROUND
EX.(+)0.58 %
EX. TCT.P. 583.28
T.C. 583.78
MATCH EX. PVM'T.
154+50.00, 32.21' RT
(+)0.57 %
(-)0.50 %582.84VPT 152+85.00 (+)0.57 %
E=0.07'
K=47
TC 582.77SAG 152+58.4150'VC
E=0.07'
K=47
TC 582.77(582.70)PI 152+60.0018" RCP3'x2' RCB
18" RCP
18"
McKINNEY STREET
590
585
580
590
585
580
PROP. TCEX.ROWPROP. TCEX.ROW590
585
580
590
585
580 MATCHLINE STA 152+5082MATCHLINE STA 152+50CV-8
804.20'
S 52° 05' 05.00" E
N = 7125695.37
E = 2405879.01
CURVE 8 (CV-8)
DEG = 2° 30' 00.00"
PI STA = 154+40.11
= 9° 39' 00.00" RT
T = 193.46'
R = 2,291.83'
L = 386.00'
POND
EX. DETENTION
F.L. 579.00
T.C. 583.50
CL 10' REC. INLET
PAV STA 154+00.00, 33.52' RT
CL McKINNEY STREET
57' (B-B)100' R.O.W.FENCE
EX. CHAIN LINK
EX. WOOD FENCE
R.O.WEX.
R.O.WEX.
SUBGRADE (36 LB/SY PER LIFT) (TYP.)
AND 12" THICK LIME STABILIZED
W/ 9" THICK TYPE B ASPHALT BASE COURSE
3" THICK TYPE C ASPHALT SURFACE COURSE
EX. GUARDRAIL
& GUTTER
24" CURB
R.O.WEX.
F.L. 578.27
T.C. 582.77
CL 10' REC. INLET
PAV STA 152+65.00, 30.47' LT
F.L. 578.27
T.C. 582.77
CL 10' REC. INLET
PAV STA 152+65.00, 33.50' RT
PATH
12' BIKE/PED
FUTURE
FUTURE 6' SIDEWALK
F.L. 579.17
T.C. 583.67
CL 10' REC. INLET
PAV STA 154+30.00, 30.18' LT
& GUTTER
24" CURB
MATCH EX. PAVEMENT
STA 154+50.00
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV17.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV17.dgn1:404:40:04 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
MAYHILL ROAD
PAVING PLAN & PROFILE
McKINNEY STREET INTERSECTION
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN ISCONCRETESSDD585.34PK NAIL SET33DDSCAB. Y, PG. 289
20' UTILITY EASEMENT
CAB. B, PG. 71
25' UTILITY EASEMENT
CAB. B, PG. 147
16' UTILITY EASEMENT
VOL. 5039, PG. 01970
DRAINAGE EASEMENT
20' PERMANENT
3922 E McKINNEY STREET
GOEL VENTURES ONE, LLC
3923 E McKINNEY STREET
DENTON 3919 McKINNEY, LLC
STREET
4001 E McKINNEY
CITY OF DENTON
E McKINNEY STREET (200' STRIP)
BCI REAL ESTATE VENTURES, LP
LOT 5R1 LOT 3
LOT 152
LOT 151 (PT)
LOT 153
E McKINNEY STREET
CITY OF DENTON
1516 E McKINNEY STREET
TALOUKIE BROS ENT INC
LOT 5R2LOT 5R2 8" W12" W12" W12" W6" W12" W12"
W
20
" W
16" W20" W
20" W 20" W20" W12" W 12" W
8" W
12" W
12" W
20" W12" W8" WW8" WW10" WW 10" WW
8" WW
8" WW
8" WW10" WW 27" RCPBOX CULVERT
6'x4'
BOX CULVERT
6'x4'
BOX CULVERT6'x4'18" RCP 18" RCP 24" RCPBOX CULVERT6'x4'
BOX CULVERT
8'x4'RCP18" 18" RCP
18" RCP
18" RCP
BOX CULVERT
6'x4'
BOX CULVERT
8'x4'12" W(ABANDONED)
10" WW
(ABANDONED)10" WW
8" WWPTZ PT
112+56
.89
PC 111+52
.17
112+00113+00114+00222+00
221+00
220+00
223+00 224+00 225+00D
D20"
W
12" W16" WSLEEVES6" PVC SLEEVES6" PVC PROP. TC LT
(+)3.94 %(+)1.50 %MATCH EX. PVMT.580.23PI 221+38.35 583.42PI 222+43.76582.82CR 222+18.69584.64PI 223+03.20EX. (+)4.68 %
(+)0.50 %
EX.
LT BACK OF CURB
EX. GROUND AT 580.26VPC 221+39.00585.18VPT 223+36.00197' UNSYMETRIC VERTICAL CURVE
(583.41)PI 222+19.00MATCH EX. PVMT585.18PI 223+36.06580.68582.32583.57584.58584.95582.48584.20580.76585.23585.49585.77578.57TC RT
PROP.
(+)4.40 %
EX. (+)0.89 %
LT BACK OF CURB
EX. GROUND AT
(+)5.40 %EX. 581.40PI 221+39.09 581.44VPC 221+40.00 582.98CR 221+84.76 (583.64)PI 221+90.00 585.82VPT 223+36.00 MATCH EX. PVMT585.82PI 223+36.06 583.75PI 222+20.11 584.90PI 222+79.68 585.30CR 223+03.22 (+)1.50 %
196' UNSYMETRIC VERTICAL CURVE
221+00 222+00 223+00 224+00581.86583.32584.35585.25586.84586.39585.50585.95584.85581.98583.95579.43577.25NOTES:
ADDITIONAL INFORMATION.
SEE TRAFFIC SIGNAL PLANS FOR4.
FOR ADDITIONAL INFORMATION.
SEE WATER PLAN AND PROFILE SHEETS3.
FOR ADDITIONAL INFORMATION.
2. SEE DRAINAGE PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE CITY OF DENTON STANDARD DETAILS
LEGEND:
FUTURE SIDEWALK
DRIVEWAY/PAVEMENT
PROPOSED CONCRETE
PAVEMENT
PROPOSED STREET
FINISHED GRADE.
CAP 4 INCHES ABOVE
OF PAVEMENT. TURN UP AND
TO EXTEND 12" BEYOND EDGE
MIN. 36" BELOW PROP. T.C.
2-6" PVC SCH 40 SLEEVES A
590
585
580
590
585
580
PROP. TCPROP. TCLINK FENCE
EX. CHAIN
590
585
580
590
585
580
83
CL MAYHILL ROAD
CL McKINNEY STREET
EX. R.O.W
EX. R.O.W
EX. R.O.W
EX. R.O.W
EX. R.O.W
EX. GR.EX. GR. 88.35'
N 4° 37' 09.29" E
STA 112+75.57 McKINNEY STREET
STA 222+65.23 MAYHILL ROAD
OFF 75.77' LT
STA 223+81.31
CL DRIVEWAY
STA 223+81.31
N MAYHILL ROAD
S MAYHILL ROAD
30'R
3
0'RCR 60.50' RT
STA 221+84.76
CR 48.50' LT
STA 222+18.70
30'
R
3
0'R20'RDRIVEWAY
CONCRETE
REINFORCED
8" THICK
12'
CR 48.50' LT
STA 223+03.22
CR 57.27' LT
STA 223+29.00
FUTURE 5' SIDEWALK
5' SIDEWALK
FUTURE
PATH
BIKE/PED
10'
FUTURE
PATH
BIKE/PED
FUTURE 10'
72
PAVING PLAN AND PROFILE
McKINNEY STREET
SEE SH. FOR McKINNEY STREETMATCH EX. CURB
OFF 53.73' LT
STA 223+36.06
MATCH EX. CURB
OFF 48.50' RT
STA 223+06.36
MATCH EX. CURB
OFF 50.50' LT
STA 221+38.35
MATCH EX. CURB
OFF 23.50'LT
STA 221+38.35
MATCH EX. CURB
OFF 0.50' RT
STA 220+80.00
MATCH EX. CURB
OFF 60.50' RT
STA 221+39.09
STANDARD DETAILS.
SEE CITY OF DENTON
MEDIAN PAVEMENT.
4" THICK COLORED CONCRETE
6" LIME TREATED SUBGRADE (TYP.)
PAVEMENT W/ 2" HMAC TYPE D AND
12" CONTINUOUSLY REINFORCED CONCRETE
REFERENCE ONLYSLEEVES6" PVC SLEEVES6" PVC A
A
SEE PAVING DETAILS
LONGITUDINAL BUTT JOINT
INSTALL 60 LF
SEE PAVING DETAILS
LONGITUDINAL BUTT JOINT
INSTALL 27 LF
SEE PAVING DETAILS
LONGITUDINAL BUTT JOINT
INSTALL 133 LF
RAMP
TYPE 1B
DENTON
CITY OF
RAMP
TYPE 1B
DENTON
CITY OF
TYPE 1B RAMP
CITY OF DENTON
RAMP
TYPE 1A
DENTON
CITY OF
RAMP
TYPE 1A
DENTON
CITY OF
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOLEGEND:
PROPOSED PAVEMENT
NOTES:
FOR ADDITIONAL INFORMATION.
SEE WATER PLAN AND PROFILE SHEETS4.
ADDITIONAL INFORMATION.
SEE PAVING DETAILS SHEET FOR3.
FOR ADDITIONAL INFORMATION.
2. SEE DRAINAGE PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE CITY OF DENTON STANDARD DETAILS
DRIVEWAY
PROPOSED CONCRETE
FUTURE SIDEWALK
McKINNEY STREET - PHASE 2
FINISHED GRADE.
CAP 4 INCHES ABOVE
OF PAVEMENT. TURN UP AND
TO EXTEND 12" BEYOND EDGE
MIN. 36" BELOW PROP. T.C.
2-6" PVC SCH 40 SLEEVES A
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV18.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPV18.dgn1:404:40:08 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
RYAN WAY
PAVING PLAN & PROFILE
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
McKINNEY STREET INTERSECTION
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PBX
E
3
6
"
T
R
EE
BCI REAL ESTATE VENTURES,LP
5090 E McKINNEY STREET
EDIBERTO A RODRIGUEZ
5101 E McKINNEY STREET
DENTON ISD
LOT 169
LOT 151 (PT)
LOT 150
LOT 1R4
5043 E McKINNEY STREET
CHELA DARLINE McDONALD
CAB. H, PG. 62
20' UTILITY EASEMENT
WVWVWV16" W16" W8" W8" W8" W10" W24" RCP27" RCP15" RCP
24" RCP
PC 129+61.61
130+00131+00132+0016" W16" W16" W10" WSLEEVES6" PVC 6" PVC SLEEVESMcKINNEY STREET84
RYAN WAY
OFF 291.48' LT
STA 130+44.81
SEE PAVING DETAILS
LONGITUDINAL BUTT JOINT
INSTALL 287 LF
SEE PAVING DETAILS
LONGITUDINAL BUTT JOINT
INSTALL 34 LF
R.O.WEX.
R.O.WEX.
CR 25.50' LT
STA 130+78.45
CR 51.67' LT
STA 131+77.25
CR 25.50' LT
STA 132+02.02
CR 54.96' LT
STA 131+08.08
W/ 8% LIME (48 LB/SY) (TYP.)
8" THICK STABILIZED SUBGRADE
W/ #4 BARS @ 18" O.C. EACH WAY
4000 PSI COMPRESSIVE STRENGTH
8" THICK REINF. CONC. PAVEMENT,
OFF 279.16' LT
STA 130+49.82
OFF 226.91' LT
STA 130+86.98
17
5'
R
9
7.
5'
R
200'R
OFF 94.59' LT
STA 131+39.54
47.5'ROFF 72.54' LT
STA 131+38.90
OFF 71.33' LT
STA 131+54.00
3'R
77
PAVING PLAN AND PROFILE
McKINNEY STREET
SEE SH. FOR
SIDEWALK
FUTURE 5'
CONCRETE STREET HEADER
INSTALL 124 LF REINFORCED
BEGIN CONCRETE PAVEMENT
END ASPHALT PAVEMENT
30'R
25'R4
7.5'RSTREET
CL McKINNEY
OFF 83.17' LT
STA 131+55.04
F.L. 579.40
T.C. 585.40
CL STD. 15' INLET
STA 131+08.64, 83.64' LT
PVMT SECTION
MATCH EX.
NOSE
MEDIAN
MONOLITHIC
F.L. 578.52
T.C. 584.52
CL STD. NCTCOG 15' INLET OPENING, 5' WIDTH
STA 131+78.94, 82.41' LT
A
SEE RYAN WAY TYPICAL SECTION
NO PROFILE THIS SHEET
TYPE 1A RAMP
CITY OF DENTON
TYPE 1A RAMP
CITY OF DENTON
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPD01.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CPD01.dgn1:404:40:10 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837NTS
E. OF LOOP 288 TO W. OF GRISSOM ROAD
PAVING DETAILS
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
85
10"
LONGITUDINAL BUTT JOINT DETAILT/2T1"6"OR 8"DRIVEDRIVEWAY GRADE
PAVEMENTSTREETN.T.S.
1" DRIVEWAY CURB DETAIL2"1"1-1/2"KEYWAY
METALT/2T/2EPOXY RESIN
AND COATED WITH APPROVED
†" HOLE INSIDE BLOWN CLEAN
EXISTING PAVINGPROPOSED PAVING
COMPACTED SUBGRADE
BEFORE INSERTION INTO HOLE)
(COAT WITH APPROVED EXPOXY RESIN
•"x2'-0" BARS @ 2'-6" SPACING
DETAILS FOR REINFORCEMENT
SEE CITY OF DENTON DRIVEWAY
NOTE:
SEALING COMPOUND 1" MIN.
HOT POURED RUBBER JOINT
DRIVEWAY MEETS EXISTING CONCRETE PAVEMENT
EXPANSION JOINT REQUIRED WHERE PROPOSED CONCRETE
PAVEMENT MEETS EXISTING CONCRETE PAVEMENT
TO BE USED WHERE PROPOSED CONCRETE
FILE:DATE:DN:DW:CK:FILE:
JOB
COUNTY
SECT
DIST
REVISIONS
HIGHWAY
SHEET NO.
CONT
SHEET 1 OF 2
TxDOT
Standard
Division
Design
HCDN:HC AN
C TxDOT:
GENERAL NOTES
* USE 12" SPACING AS FIRST AND LAST SPACING AT END OR SIDE FOR ALL BARS.
AND BAR SIZE
SLAB THICKNESS
(IN.)
T
SIZE
BAR
8.5
6.0
#5
6.0
6.5
7.0
7.5
8.0
8.5
9.0
9.5
7.5
7.0
6.5
9.0
8.0
7.5
TIEBARSPAVEMENT
TYPE
JRCP
6.0
6.5
#610.0
10.5
11.0
11.5
#5<8.0
7.0
6.75
6.25
24.0
CRCP
(IN.)
SPACING
(IN.)
SPACING
8.5
6.0
7.5
7.0
6.5
9.0
8.0
7.5
6.0
6.5
7.0
6.75
6.25
12.0
>12.0
TABLE NO.1 STEEL BAR SIZE AND SPACING
LONGITUDINAL*TRANSVERSE*
REGULAR BARS
>8.0 #6 24.0 12.0
#5<8.0
>8.0 #6
CPCD NONE 12.0
NONE 12.0
BARS
(IN.)
SPACING
TIEBARS
(IN.)
SPACING
24
24
24
24
24
24
24
24
NONE
NONE
24
24
EXTENDED INTO THE REPAIR PATCH.
EXISTING CONCRETE. MIN.25"
MIN.10" EPOXY-GROUTED INTO
TOP OF DRILLED HOLES AT T/2.
TRANSVERSE TIEBARS -
10" MIN.
T/2
T/2
MIN.25" EXTENDED INTO THE REPAIR PATCH.
MIN.10" EPOXY-GROUTED INTO EXISTING CONCRETE.
BOTTOM OF DRILLED HOLES AT T/2.
LONGITUDINAL TIEBARS -
PLACED IN ONE LAYER AND TIED TO TIEBARS.
BAR LENGTH IS LENGTH OF REPAIR MINUS 2".
LONGITUDINAL BARS -
REPAIR PATCH
6' MIN.
NOTES
SEE GENERAL HALF OR FULL LANE WIDTHPLAN VIEW
SEE DETAIL A
BASE
RECOMPACTED
AND TIED TO TIEBARS.
MINUS 2". PLACED IN ONE LAYER
BAR LENGTH IS WIDTH OF REPAIR
TRANSVERSE BARS -
1.ITEM 361,"REPAIR OF CONCRETE PAVEMENT"SHALL GOVERN FOR THIS WORK.
"CONCRETE PAVING DETAILS, JOINT SEALS."
OPERATION SHOULD BE RESTORED IN ACCORDANCE WITH STANDARD SHEET
3.EXISTING LONGITUDINAL AND TRANSVERSE JOINTS REMOVED DUE TO REPAIR
1.ITEM 361,"REPAIR OF CONCRETE PAVEMENT"SHALL GOVERN FOR THIS WORK.
BE PLACED IN TWO STAGES DUE TO SEQUENCE OF CONSTRUCTION.
2.MULTIPLE PIECE TIEBARS SHALL BE USED WHEN THE REPAIR AREA MUST
PAVEMENT EDGE AND TO THE CENTER LINE OF THE PAVEMENT.
TO BE REPAIRED. THE CUT SHALL BE MADE AT A RIGHT ANGLE TO THE
3.FULL DEPTH SAW CUTS SHALL BE MADE AROUND THE PERIMETER OF THE AREA
EXISTING LONGITUDINAL JOINT.
4.AT LEAST ONE LONGITUDINAL FULL DEPTH SAW CUT SHALL BE AT AN
THE FULL DEPTH SAW CUT AT THE REPAIR EDGE.
TO FACILITATE REMOVAL OF THE CONCRETE OR TO ALLEVIATE BINDING OF
5.ADDITIONAL SAW CUTS MAY BE REQUIRED WITHIN THE AREA OF THE REPAIR
ENGINEER.
CLEANED AND FILLED WITH A CEMENTITIOUS GROUT APPROVED BY THE
6.THE SAW CUTS WHICH EXTEND OUTSIDE THE AREA OF THE REPAIR WILL BE
"CONCRETE PAVING DETAILS, JOINT SEALS."
OPERATION SHOULD BE RESTORED IN ACCORDANCE WITH STANDARD SHEET
7.EXISTING LONGITUDINAL AND TRANSVERSE JOINTS REMOVED DUE TO REPAIR
GENERAL NOTES
ENGINEER.
CLEANED AND FILLED WITH A CEMENTITIOUS GROUT APPROVED BY THE
2.THE SAW CUTS WHICH EXTEND OUTSIDE THE AREA OF THE REPAIR WILL BE
GROUTED TIEBARS & REINFORCEMENT
DETAIL A
FULL-DEPTH REPAIR OF CRCP, JRCP, AND CPCD
A A
PLAN VIEW
SECTION A-A
T
12" MIN.12" MIN.DISTRESSED CONCRETE
SAW CUT REPAIR BOUNDARIES
SOUND CONCRETE
SOUND CONCRETE
SOUND CONCRETE
LONGITUDINAL STEEL BARS:
DO NOT SAW-CUT STEEL BARS.
SAW CUT DEPTH: MIN.1 1/2"
DO NOT SAW-CUT STEEL BARS.
SAW CUT DEPTH: MIN.1 1/2"
BE MADE.
THE REMOVAL OPERATIONS. NO ADDITIONAL COMPENSATION WILL
AS DIRECTED IF LONGITUDINAL STEEL BARS WERE DAMAGED BY
*INCREASE THE REPAIR AREA AND PERFORM A FULL-DEPTH REPAIR
VOLUMES OF REPAIR AREAS OR CHANGES IN SCOPE OF WORK.
AS APPROVED. COMPENSATION WILL BE MADE FOR UNEXPECTED
REPAIR IF EXPOSED EXISTING LONGITUDINAL BARS ARE DEFICIENT,
CONCRETE. SWITCH THE HALF-DEPTH REPAIR TO FULL-DEPTH
*REPAIR AREAS MAY BE ADJUSTED AFTER REMOVING DISTRESSED
ONLY SOUND CONCRETE IS LEFT IN PLACE.
CLEAN THE AREA BY APPROVED METHODS.
REMOVE ALL LOOSE MATERIALS AND
REPAIR OF CONCRETE PAVEMENT
HALF-DEPTH REPAIR
DECEMBER 2014
repcp14.dgn
REPCP-14TxDOT assumes no responsibility for the conversion of this standard to other formats or for incorrect results or damages resulting from its use.The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of any kind is made by TxDOT for any purpose whatsoever. DISCLAIMER:86
FILE:DATE:DN:DW:CK:FILE:
JOB
COUNTY
SECT
DIST
REVISIONS
HIGHWAY
SHEET NO.
CONT
SHEET 2 OF 2
TxDOT
Standard
Division
Design
HCDN:HC AN
C TxDOT:
A A
PLAN VIEW
SECTION A-A
LENGTH
T
• DOWEL
TO PREVENT BOND
COAT ENTIRE DOWEL
38" MIN.38" MIN.HALF OR FULL LANE WIDTHPATCH
REPAIR
PATCH
REPAIR
EXTENDED INTO THE REPAIR PATCH.
EXISTING CONCRETE. MIN.25"
MIN.10" EPOXY-GROUTED INTO
TOP OF DRILLED HOLES AT T/2.
TRANSVERSE TIEBARS -
STOP TIEBARS ABOUT 4" FROM THE DOWEL ASSEMBLY.
WHICH WILL PREVENT BONDING TO THE CONCRETE.
JOB SITE.COAT ENTIRE DOWEL BAR WITH A MATERIAL
DELIVER PREFABRICATED DOWEL ASSEMBLIES TO THE
SEE TABLE NO.2 FOR DOWEL BAR SIZE AND SPACING.
SMOOTH DOWEL BARS
T/2
T/2
T/2
38" MIN.JOINT
TRANSVERSE
10" MIN.
MIN.25" EXTENDED INTO THE REPAIR PATCH.
MIN.10" EPOXY-GROUTED INTO EXISTING CONCRETE.
BOTTOM OF DRILLED HOLES AT T/2.
LONGITUDINAL TIEBARS
JOINT SEALS: METHOD A OR B
SAW CUT DEPTH: T/3
TIEBARS
SMOOTH DOWEL BARS
NOTES
SEE GENERAL
BE PLACED IN TWO STAGES DUE TO SEQUENCE OF CONSTRUCTION.
2.MULTIPLE PIECE TIEBARS SHALL BE USED WHEN THE REPAIR AREA MUST
PAVEMENT EDGE AND TO THE CENTER LINE OF THE PAVEMENT.
TO BE REPAIRED. THE CUT SHALL BE MADE AT A RIGHT ANGLE TO THE
3.FULL DEPTH SAW CUTS SHALL BE MADE AROUND THE PERIMETER OF THE AREA
EXISTING LONGITUDINAL JOINT.
4.AT LEAST ONE LONGITUDINAL FULL DEPTH SAW CUT SHALL BE AT AN
THE FULL DEPTH SAW CUT AT THE REPAIR EDGE.
TO FACILITATE REMOVAL OF THE CONCRETE OR TO ALLEVIATE BINDING OF
5.ADDITIONAL SAW CUTS MAY BE REQUIRED WITHIN THE AREA OF THE REPAIR
ENGINEER.
CLEANED AND FILLED WITH A CEMENTITIOUS GROUT APPROVED BY THE
6.THE SAW CUTS WHICH EXTEND OUTSIDE THE AREA OF THE REPAIR WILL BE
"CONCRETE PAVING DETAILS, JOINT SEALS."
OPERATION SHOULD BE RESTORED IN ACCORDANCE WITH STANDARD SHEET
7.EXISTING LONGITUDINAL AND TRANSVERSE JOINTS REMOVED DUE TO REPAIR
1.ITEM 361,"REPAIR OF CONCRETE PAVEMENT"SHALL GOVERN FOR THIS WORK.
BASE
RECOMPACTED
BASE
RECOMPACTED
TRANSVERSE JOINT
GROUTED TIEBARS & DOWELS
DETAIL B
REPAIR OF TRANSVERSE JOINT OF CPCD
SEE DETAIL B
>
PAVEMENT
THICKNESS LENGTH
TABLE NO. 2 DOWELS (SMOOTH BARS)
SPACINGSIZE AND DIA.
#8 (1 IN.)
#10 (1‚IN.)10
(INCHES)
<10
(IN.)(IN.)
18.0 12.0
BASKETS ARE USED, REMOVE THE SHIPPING WIRES.
AND VERTICALLY UNLESS OTHERWISE SPECIFIED. WHERE DOWEL BAR
8.DOWEL BAR PLACEMENT TOLERANCE SHALL BE +/- 1/4 IN. HORIZONTALLY
GENERAL NOTES
REPAIR OF CONCRETE PAVEMENT
DECEMBER 2014
REPCP-14
repcp14.dgnDISCLAIMER:The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of any kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion of this standard to other formats or for incorrect results or damages resulting from its use.87
DN:CK:DW:CK:FILE:
JOB
COUNTY
SECT
DIST
REVISIONS
HIGHWAY
SHEET NO.
CONT
FILE:DATE:TxDOT
Bar B
2"6"
3"
•T
T
3"
24"
2"6"2"RT
3"
•T 3"
24"
2"6"6"R2"6"2"RT
8"
•T
T
•T
3"
8"6"R2"6"6"R2" to 4"
8"
2"6"2"R8"
•T
2 •"
2 •"
3 •"•"
2" to 4"2" to 4"
T
Bar C
Bar C
3"
2" - 4" HEIGHT
TYPE I CURB (MONOLITHIC)2" - 4" HEIGHT
TYPE I CURB AND GUTTER
5" - 5 Æ’" HEIGHT
TYPE II CURB
5" - 5 Æ’" HEIGHT
TYPE II CURB AND GUTTER
5" or 5 Æ’"5" or 5 Æ’"
5" or 5 Æ’"
5" - 5 Æ’" HEIGHT
TYPE II CURB (MONOLITHIC)
(See Note 12)
Joint
Construction
Permissible
(See Note 12)
Steel
Usual Pavement
(See Note 12)
Joint
Construction
Permissible
2" - 4" HEIGHT
TYPE I CURB
(See Note 12)
Steel
Usual Pavement
(See Note 10)
Profile Grade Line
(See Note 10)
Profile Grade Line
(See Note 10)
Profile Grade Line
(See Note 10)
Profile Grade Line
(See Note 10)
Profile Grade Line
(See Note 10)
Profile Grade Line
plans,or as directed by the Engineer.
shall be shown elsewhere in the
longer or shorter transition, and
Field conditions may require a
Curb Transition Note:
General Notes
reinforcing bars shall be placed at four feet C~C.
8. Vertical and horizontal dowel bars and transverse
at locations directed by The Engineer.
provided at structures, curb returns at streets, and
to concrete pavement, expansion joints shall be
placement of curb or curb and gutter is not adjacent
gutter adjacent to jointed concrete pavement. Where
to match pavement joints in all curbs and curb and
7. Expansion and contraction joints shall be constructed
reinforcing bars grouted in place.
pavement, the pavement shall be drilled and the
6. Where concrete curb is placed on existing concrete
sawed or removed at existing joints.
5. All existing curbs and driveways to be removed shall be
minimum radius of ‚inch.
4. Round exposed sharp edges with a rounding tool, to a
Construction Division.
the Department Producer List (MPL), maintained by TxDOT,
reinforcing is acceptable, provided the fiber producer is on
otherwise shown. The use of synthetic fiber in lieu of steel
3. When reinforcing bars are used, they shall be No.4 unless
2. Concrete shall be Class A.
Curb and Gutter."
with Item 529, "Concrete Curb, Gutter, and Combined
1. All materials and construction shall be in accordance
conform to that required for concrete curb.
joints. Reinforcing steel for curb section shall then
elsewhere in the plans for longitudinal construction
placed in accordance with pavement details shown
pavement, the longitudinal pavement steel shall be
resulting in a longitudinal construction joint in the
12. When vertical permissible construction joints are used,
or riprap.
where curb or curb and gutter is adjacent to sidewalk
11. One-half inch expansion joint material shall be provided
and plan-profile sheets for exact locations.
10. Usual profile grade line. Refer to typical sections
pavement dimension 'T' is 8" maximum.
pavement. When curb is installed adjacent to flexible
9. Dimension 'T' shown is the thickness of concrete
BAR C
BAR B
Varies
12"
CURB TRANSITION
T
Top of Curb
Top of Pavement
Height
Change in
(See Curb Transition Note)
10'-0" Curb Transition (0" to 2"),
Note: To be paid for as Highest Curb
3"
2"
3"
2"
3"•T
T
6"
T
•T
Bar C
7"1"
2"
8"3"R3"R8"
6"
7"
2"
1"3"R3"R24"
for curb height= 5 Æ’"
for curb height= 5"
5" or 5 Æ’"
for curb height= 5"
for curb height= 5 Æ’"
5" or 5 Æ’"
(See Note 12)
Joint
Construction
Permissible
(See Note 10)
Profile Grade Line
(See Note 10)
Profile Grade Line
5" - 5 Æ’" HEIGHT
TYPE IIa CURB
5" - 5 Æ’" HEIGHT
TYPE IIa CURB AND GUTTER
2"6"
2" to 4"
8"
2"2"R8"
5" or 5 Æ’"
(See Note 10)
Profile Grade Line
(See Note 10)
Profile Grade Line
6"R
6"
5"
5"
1"
1"
Concrete Pavement
Asphalt or
2" - 4" HEIGHT
TYPE III CURB (KEYED)
Concrete Pavement
Asphalt or
Joint
Construction
Permissible
Joint
Construction
Permissible
5" - 5 Æ’" HEIGHT
TYPE IV CURB (KEYED)
2"
3"
3"
2 •"
2 •"
1995
AM VP
88
Standard
Division
Design
cccg12.dgn
C TxDOT:
UPDATED 2012 - VPEXPANSION JOINT DETAIL
•T
Joint Material
•" Wide Expansion
T
10"14"1•"
to wrap bars and plug end
Use 2 layers of roofing felt
Top of Pavement
Smooth Dowels
2 ea ~ ‡"x 24"
Top of Curb
CCCG-12
CURB AND GUTTER
CONCRETE CURB AND
VP
TxDOT assumes no responsibility for the conversion of this standard to other formats or for incorrect results or damages resulting from its use.The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of any kind is made by TxDOT for any purpose whatsoever. DISCLAIMER:
UTILITY LOCATION NOTE:
The location of existing utilitiesshown on these plans areapproximate and based onexisting plans and datafurnished by utility companies.It is the responsibility of thecontractor to verify the locationand depth of all existing utilitiesthat may conflict withconstruction. Call1-800-344-8377 two workingdays prior to construction foronsite locations. Any damageto existing utlities shall berepaired at contractor'sexpense, at no additional cost.
UTILITY LOCATION NOTE:
The location of existing utilitiesshown on these plans areapproximate and based onexisting plans and datafurnished by utility companies.It is the responsibility of thecontractor to verify the locationand depth of all existing utilitiesthat may conflict withconstruction. Call1-800-344-8377 two workingdays prior to construction foronsite locations. Any damageto existing utlities shall berepaired at contractor'sexpense, at no additional cost.
APS CABLE RUNS
CNDR
COLOR
CABLE NO. 1
FROM P-2
TO CNTRL
2 CNDR
CABLE NO. 2
FROM P-2
TO CNTRL
2 CNDR
CABLE NO. 3
FROM P-3
TO CNTRL 2
CNDR
CABLE NO. 4
FROM P-6 TO
CNTRL 2
CNDR
BLACK APS COMMON APS COMMON APS COMMON APS COMMON
WHITE APS POWER APS POWER APS POWER APS POWER
CABLE RUNS
CNDR
COLOR
CABLE NO. 1
FROM P-1 TO
CNTRL 21
CNDR
CABLE NO. 2
FROM P-4
TO CNTRL
21 CNDR
CABLE NO. 3
FROM P-5
TO CNTRL
21 CNDR
CABLE NO. 4
FROM P-3
TO CNTRL
21 CNDR
CABLE NO. 5
FROM P-2
TO CNTRL
12 CNDR
CABLE NO. 6
FROM P-6
TO CNTRL
12 CNDR
WHITE/
BLACK PB COMMON PB COMMON PB COMMON P.B. COMMON P.B. COMMON P.B. COMMON
WHITE S.
COMMON
S.
COMMON
S.
COMMON
S.
COMMON
S.
COMMON
S.
COMMON
RED SH 1, 2
06-R
SH 4, 5
02-R SPARE SPARE SPARE SPARE
GREEN SH 1, 2
06-G
SH 4, 5
02-G SPARE SPARE SPARE SPARE
ORANGE SH 1, 2
06-Y
SH 4, 5
02-Y SPARE SPARE SPARE SPARE
BLUE SPARE SH 3
05-G ARROW SPARE SH 13
05-G ARROW SPARE SPARE
BLACK SPARE SH 3
05-Y ARROW SPARE SH 13
05-Y ARROW SPARE SPARE
RED/
BLACK SPARE SPARE SPARE PH-11
02-DW
PH-9
06-DW SPARE
GREEN/
BLACK SPARE SPARE SPARE PH-11
02-W
PH-9
06-W SPARE
ORANGE/B
LACK SPARE SPARE SPARE SPARE PH-10
08-DW
PH-12
02-DW
BLUE/
BLACK SPARE SPARE SPARE SPARE PH-10
08-W
PH-12
02-W
BLACK/
WHITE SPARE SH 14
03-Y ARROW
SH 6
03-Y ARROW SPARE SPARE SPARE
RED/
WHITE SPARE SH 14
03-R ARROW
SH 6
03-R ARROW SPARE
GREEN/
WHITE SPARE SH 14
03-G ARROW
SH 6
03-G ARROW SPARE
BLUE/
WHITE SPARE SPARE SPARE SPARE
BLACK/
RED SPARE SH 3
05-R ARROW SPARE SH 13
05-R ARROW
WHITE/
RED SPARE SPARE SPARE SPARE
ORANGE/
RED SPARE SPARE SH 7, 8
08-R ARROW SPARE
BLUE/ RED SPARE SH 3
05-FY ARROW SPARE SH 13
05-FY ARROW
RED/
GREEN SPARE SPARE SH 7, 8
08-G ARROW SPARE
ORANGE/
GREEN SPARE SPARE SH 7, 8
08-Y ARROW SPARE
RADAR DETECTION ZONE*
RADAR #POLE #HEIGHT OF RADAR DETECTION ZONE NO. OF CHANNELS
VIDEO
DETECTION 1 -
PHASE 2 AND PHASE 5 AT STOP
BAR -
PHASE 3 AT STOP BAR -
PHASE 6 AT STOP BAR -
RS1 1 19'PHASE 6 FROM STOP BAR TO 400'
BACK -
RS2 4 19'PHASE 2 FROM STOP BAR TO 400'
BACK -
RS3 6 19'PHASE 3 FROM STOP BAR TO 400'
BACK -
TRAFFIC SIGNAL ARMS
SIGNAL HEAD & POLE PLACEMENT SIGNAL POLE
FOUNDATION
LUM
CNDRS & CABLES INSIDE POLE (LF)
POLE
NUMBER
MAST
ARM
LENGTH
*A *B C D E G
NUMBER OF
SIGNAL
HEADS
5C 7C **OPTICOM
2C #12
CABLE
(LUM)
3C #14
STREET
SIGN
**PRESENCE
RADAR CABLE
**SETBACK
RADAR
CABLE
**PTZ CABLEFDN
TYPE
DS
LENGTH
LF LF LF LF LF LF LF EA EA LF EA LF LF LF LF LF LF LF LF
P-1 36 18.5 22.5 10 18 2 36-A 14 1 101 54 80 25 40 54
P-4 36 4 11.5 10 10 18 4 36-A 14 1 138.5 54 80 25 20 54 35
P-5 36 15.5 10 10 10 18 3 36-A 14 1 129 54 80 25 20 54
P2 7 24-A 6 20
P3 16.5 1 24-A 6 10 21.5
P6 7 24-A 6 10
TOTAL 10 60 3 40 390 162 240 75 80 162 35
GROUND BOX SUMMARY
PULL BOX TYPE QUANTITY
(EA)
TYPE D W/APRON 7
APS UNITS
P-2 2
P-3 1
P-6 1
TOTAL 4
RYAN WAY
SIGNAL HEAD SUMMARY TRAFFIC SIGNAL LENS
SIGNAL
HEAD NO.
SIGNAL
HEAD TYPE
12 INCH SIGNAL 12" LED
BACK PLATE RED YELLOW GREEN RED
ARROW
YELLOW
ARROW
GREEN
ARROW
PED SIG MODULE
(COUNTDOWN)3 SEC 4 SEC
EA EA EA EA EA EA EA EA EA
1 H3 1 1 1 1
2 H3 1 1 1 1
3 *H4FLT 1 1 2 1
4 H3 1 1 1 1
5 H3 1 1 1 1
6 H3LT 1 1 1 1
7 H3RT 1 1 1 1
8 H3RT 1 1 1 1
9 PED 1
10 PED 1
11 PED 1
12 PED 1
13 *H4FLT 1 1 2 1
14 H3LT 1 1 1 1
TOTAL 8 2 4 4 4 6 8 6 4
CONDUIT RUNS
RUN NO.
ITEM 618 SIZE/TYPE
CONDUIT (FEET)
ITEM 620 ELECTRICAL
CONDUCTORS ITEM 684 SIG CAB
LENGTH OF RUN(FEET)2 IN. PVC2 IN. PVC BORE3 IN. PVCTRENCHED3 IN. PVC BORE4 IN. PVCTRENCHED4 IN. PVC BOREDNO. 4 XHHW WIRENO. 6 XHHW WIRENO. 6 BARE WIRE3C 14AWG WIRE(LUM)3C 14AWG WIRE(ILSN)****OPTICOM CABLE(4C 20 AWG)2C #12CABLE21C #14 CABLE12C #14 CABLE* VIDEODETECTION CABLE(CAT5E & 3C16AWG)* SETBACK RADARCABLE*PTZ CABLE(CAT5E & 3C16AWGLF LF LF LF LF LF EA EA EA EA EA EA EA EA EA EA EA EA
1 15 1 2 2 1 1 2 1 25
2 19 1 2 2 29
3 108 108 1 2 2 1 2 1 2 2 1 118
4 15 1 1 1 25
5 92 92 1 1 1 102
6 17 1 2 2 1 1 1 1 1 27
7 80 1 2 2 1 2 1 1 1 1 90
8 19 1 1 1 29
9 28 1 2 2 1 1 2 2 1 1 1 38
10 16 1 2 2 1 1 1 26
11 19 1 4 4 2 1 3 2 1 2 1 29
12 18 1 2 2 1 2 1 2 1 28
13 18 1 1 2 2 2 2 1 28
14 36 2 1 46
15 45 1 6 6 55
16 25 3 1 35
17 24 3 1 34
**18 16 1 26
**19 16 1 26
****20 65 75
*****21 121 121 131
TOTAL 176 0 498 0 459 0 207 92 816 1094 1094 466 502 750 786 554 466 212 816
UTILITY LOCATION NOTE:
The location of existing utilitiesshown on these plans areapproximate and based onexisting plans and datafurnished by utility companies.It is the responsibility of thecontractor to verify the locationand depth of all existing utilitiesthat may conflict withconstruction. Call1-800-344-8377 two workingdays prior to construction foronsite locations. Any damageto existing utlities shall berepaired at contractor'sexpense, at no additional cost.
UTILITY LOCATION NOTE:
The location of existing utilitiesshown on these plans areapproximate and based onexisting plans and datafurnished by utility companies.It is the responsibility of thecontractor to verify the locationand depth of all existing utilitiesthat may conflict withconstruction. Call1-800-344-8377 two workingdays prior to construction foronsite locations. Any damageto existing utlities shall berepaired at contractor'sexpense, at no additional cost.
UTILITY LOCATION NOTE:
The location of existing utilitiesshown on these plans areapproximate and based onexisting plans and datafurnished by utility companies.It is the responsibility of thecontractor to verify the locationand depth of all existing utilitiesthat may conflict withconstruction. Call1-800-344-8377 two workingdays prior to construction foronsite locations. Any damageto existing utlities shall berepaired at contractor'sexpense, at no additional cost.
UTILITY LOCATION NOTE:
The location of existing utilitiesshown on these plans areapproximate and based onexisting plans and datafurnished by utility companies.It is the responsibility of thecontractor to verify the locationand depth of all existing utilitiesthat may conflict withconstruction. Call1-800-344-8377 two workingdays prior to construction foronsite locations. Any damageto existing utlities shall berepaired at contractor'sexpense, at no additional cost.
September 3, 2019\\HZDALLAS1\disk1\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.2 AutoCAD\TRAFFIC\Details
September 3, 2019\\HZDALLAS1\disk1\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.2 AutoCAD\TRAFFIC\Details3
3
3
3
DENTON18September 3, 2019\\HZDALLAS1\disk1\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.2 AutoCAD\TRAFFIC\Details97
Traffic Operations Division
Texas Department of Transportation
POLE FOUNDATION
TRAFFIC SIGNAL
FDN
TYPE
LOCATION
IDENTIFICATION
TOTAL DRILLED SHAFT LENGTHS
FOUNDATION SUMMARY TABLE
DRILLED SHAFT LENGTH
(FEET)
42-A36-B36-A30-A24-A/ft.
BLOW
N
AVG.
EA
NO.
3
6
1'-0"Drilled Shaft LengthTraffic Signal Pole
NOTES
Table for size & pitch)
bottom. (See Design
top & 1 flat turn
Spiral, 3 flat turns
& number).
Design Table for size
Vertical Bars (See
ELEVATION
FOUNDATION DETAILS3" or as directedby the Engineer1"2"(Temporary)
Template
Circular Steel
18"MinTemplate
Steel
Circular
pitch1'-0"Shaft Dia
Drilled
TYPICAL STRAIN POLE
ASSEMBLY
Wire loads.
tension from the Span
so that two bolts are in
approximately oriented
Anchor bolts to be
R R12
Arm (optional)
Luminaire
required)
the Engineer. 1 or 2
Orient as directed by
Sheets for diameter.
Conduit (See Layout
Sway Cable
Span Wires
TYPICAL MAST ARM
Arm (optional)
LuminaireArm
Supporting
ILSN
ASSEMBLY+-+-8'-0"19'-6"19'-6"35' Lum. Mounting HeightR12
3"
Spiral
Conduit
TOP VIEW
Bars
Vertical
Diameter
Bolt CircleRTYPE
FDN
DIA
SHAFT
DRILLED STEEL
REINFORCING
BARS
VERT
& PITCH
SPIRAL
DIA
BOLT
ANCHOR
(ksi)
Fy
K-ft
MOMENT
Kips
SHEAR
24-A 24" 36 10
30-A 30" 55 87
36-A 36" 55 131
36-B 36" 55 190
42-A 42" 55 271
10- 9
12- 9
14- 9
1
2
2
2
2
TYPE
ANCHOR
1
3
5
7
9
TYPICAL APPLICATION
Strain pole taller than 30' & strain
pole with mast arm
10 15 40
FOUNDATION DESIGN TABLE
DIA
CIR
BOLT
controller.
Pedestal pole, pedestal mounted
Mast arm assembly. (see Selection Table)
30' strain pole with or without luminaire.
Mast arm assembly. (see Selection Table)
Mast arm assembly. (see Selection Table)
Mast arm assembly. (see Selection Table)
2 at 12"
3 at 6"
3 at 6"
3 at 6"
3 at 6"
TOP BOLT R R12
1 •"
1 Æ’"
2"
Æ’"
2 ‚"
1'-6"
3'-4"
3'-10"
4'-3"
4'-9"
3"
6"
7"
8"
4"
4 •"
12 Æ’"
17"
19"
21"
23"
7 „"
10"
11 ‚"
12 •"
13 Æ’"
7"
7 Æ’"
8 •"
9 ‚"
ANCHOR BOLT & TEMPLATE SIZES
longer bolts are acceptable.
Min dimensions given,
BOLT
DIA THREAD THREAD
6"
9"
5 †"
MAX SINGLE ARM LENGTH
MAX SINGLE ARM LENGTH
LENGTH COMBINATIONS
MAXIMUM DOUBLE ARM
LENGTH COMBINATIONS
MAXIMUM DOUBLE ARM
32'48'
24' X 24'
28' X 28'
32' X 28'32' X 32'
44' X 28'44' X 36'
36'44'
24' X 24'
28' X 28'
32' X 24'
36' X 36'
40' X 36'
32' X 32'
36' X 36'
40' x24'80 MPH DESIGNWIND SPEED100 MPH DESIGNWIND SPEEDMAX SINGLE ARM LENGTH
ARM PLUS ILSN SUPPORT ASSEMBLIES (ft)
FOUNDATION SELECTION TABLE FOR STANDARD MAST
36-A can support a single 36' mast arm.
For 100mph design wind speed, foundation
another arm up to 28'
30-A can support up to a 32' arm with
For 80mph design wind speed, foundation1.
2.
EXAMPLE:
Type 1
Type 2
R=d
Nut (Typ)
Heavy Hex
TopThread1 •" MinAnchor Bolt Length(See Table)d
Bott ThreadANCHOR BOLT ASSEMBLY
HOOKED ANCHOR NUT ANCHOR
(TYPE 1)(TYPE 2)
40' X 36'
44' x 36'
FDN 36-B FDN 42-A
N blows/ft
CIRCLEIN.
BOLT
LENGTH
Bolt
Anchor
1
2
3
4
5
6
7
17-'6"Nominal..
8- 9
4- 5
2LOAD
DESIGN
FOUNDATIONANCHOR BOLT DESIGN
1
7
foot for entry into Summary Table.
penetrometer values. Round to nearest
to allow interpolation for other
Decimal lengths in Design Table are
diameters into solid rock.
Shaft shall extend a minimum of two
If rock is encountered, the Drilled
used to adjust shaft lengths.
of approximately 3 to 5 feet may be
Field Penetrometer readings at a depth
for the Contractor's information only.
of location and type. Quantities are
or grouped according to similarity
Foundations may be listed separately
the base of the structure.
allowable moments and shears at
Foundation Design Loads are the
Foundation Design Loads.
foundation capacity given under
Anchor bolt design develops the
TEXAS CONE PENETROMETER
FDN 36-AFDN 30-A
concrete is placed.
to do so when
if material is firm enough
on bottom of drilled hole
Vertical bars may rest
encasement.
Listed for concrete
connectors shall be UL
jumper. Mechanical
bar or #6 copper
locations using #3
rebar cage, two
Bond anchor bolts to
BOTTOM
Clamp Arm Length F
ixed A
rm
Leng
th
8
8 (See Summary Table) Embedded Dr Shaft Length5"
5 •"
LENGTH-ft 4 , 5 , 6
EMBEDDED DRILLED SHAFT
5.7
11.3
13.2
15.2 13.6
12.0
10.3
17.4
5.3
15.6
4.5
8.0
9.4
10.4
11.9
Æ’"
1 •"
1 Æ’"
2"
2 ‚"
12 Æ’"
17"
19"
21"
23"
tension under dead load.
ensure that two bolts are in
with the fixed arm direction to
Orient anchor bolts orthogonal
Ignore the top 1' of soil.
embedded shaft.
the top third of the
Use average N value over
concrete
project above
bolt shank shall
‚" to •" of
per Anchor Bolt
2 Flat Washers
than bolt diameter
with holes ˆ" greater
Steel Template
Top Template
Circular Steel
‚" thk. min.
for FDN 24-A)
(Omit bottom template
Circular Steel Bottom Template
d/4 (inch) min.
Thickness =
2 Sides
(Typ)Galvanize Length= Top Threadplus 6" Min. sion of this standard to other formats or for incorrect results or damages resulting from its use. kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conver-DISCLAIMER: The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of any FILE:DATE:August 1995C TxDOT
REVISIONS
128
DN:CK:DW:CK:
JOB
COUNTY
CONT SECT
DIST
HIGHWAY
SHEET NO.
MS JSY MA0/MMF JSY/TEB
5-96
11-99
1-12
Ground Rod
Copper Clad
5/8" Dia. x 10'
1
MODIFICATIONS:
1
TS-FD-12 (DAL)
ADDED GROUND ROD TO FOUNDATION DETAILS (9/15)
1
2" Max.GENERAL NOTES:
rod clamps shall be listed for their intended purpose.
Make connections to ground rods according to NEC. Ground
a maximum of 2" above the finish grade of the foundation.
Ground rod shall protrude a minimum of 1"and
structure in accordance with Item 449, "Anchor Bolts".
Lubricate and tighten anchor bolts when erecting the
Templates and embedded nuts need not be galvanized.
accordance with Item 445, "Galvanizing".
shall be galvanized. All galvanizing shall be in
otherwise noted. Exposed washers and exposed nuts
thread length plus 6" for all anchor bolts unless
to ASTM A36. Galvanize a minimum of the top end
bolts that are 1" in diameter or less shall conform
mild steel" per Item 449, "Anchor Bolts". Anchor
shall conform to "alloy steel" or "medium-strength
Anchor bolts that are larger than 1" in diameter
Galvanized nuts shall be tapped after galvanizing.
and nuts shall have Class 2A and 2B fit tolerances.
in diameter or UNC series for all sizes. Bolts
rolled or cut threads of 8UN series up to 2"
Threads for anchor bolts and nuts shall be
Concrete shall be Class "C".
"Reinforcing Steel".
Reinforcing steel shall conform to Item 440,
Signals and interim revisions thereto.
Highway Signs, Luminaires and Traffic
Specifications for Structural Supports for
Design conforms to 1994 AASHTO Standard
DENTON18
24-A
36-A
10
10
3
3 40.5
18
*18 40.5
MCKINNET ST @RYAN WAY
\\HZDALLAS1\disk1\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.2 AutoCAD\TRAFFIC\Details98September 3, 2019
DENTON18September 3, 2019\\HZDALLAS1\disk1\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.2 AutoCAD\TRAFFIC\Details99
A
A
B
Section A-A
Section B-B
pin
S.S. cotter
mounting block
Cast alum.
•" S.S. bar
with bronze
sleeve bearings
and locking pin.
lamps
Fluorescent
Ballast
5Æ’"
6"
23"
(max.)
1‹"
Internally lighted
street name sign
Sign length;
INTERNALLY LIGHTED STREET NAME SIGN DETAILS
14" to
16•"
9" to 11•"6 or 8 feet as shown elsewhere in plans.
ILSN SIGN
o
EXPLANATION OF DESCRIPTION
MOUNTING BRACKET
6 or 8 ft.
one straight
connector,
three - #12 XHHW
conductors.
Æ’" Liquid tight
one 90 connector,
Æ’" S.S.
flexible metal conduit,
and Arm Detail
ILSN Sign 6
Hand Hole
see "MA-D".
Single or double face
B
pipe
threaded to
End cap
signal mast arm
3"
Sched. 40
pipe support arm
24"
6' for 6' signs, 8' for 8' signs
7' for 6' signs, 9' for 8' signs
3" min., 12" max.
3"
Sched. 40
pipe support arm
Mounting
bracket
attachment.
fixture
Slide track
S
Hand Hole
see "MA-D".
SIGN MOUNTING
2 bevel washers
nut, lock washer,
H.H. bolt - 5" min. length,
ILSN SIGN NOTES:
1. Eight foot ILSN sign shall not exceed 11.5 sq.ft.
effective projected area (EPA) and shall not exceed
a weight of 85 lbs.
Six foot ILSN sign shall not exceed 8.7 sq.ft. EPA
and shall not exceed a weight of 70 lbs.
2. Sign message shall be as shown elsewhere in the plans.
3. See Special Specification, "internally Lighted Street
Name Signs" for additional details.
See "MA-C (ILSN)" for Clamp
SNS-95
(ILLUMINATED)
SIGN DETAILS
STREET NAME
Texas Department of Transportation sion of this standard to other formats or for incorrect results or damages resulting from its use. kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conver-DISCLAIMER: The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of any FILE:DATE:Traffic Operations Division
DN:CK:DW:CK:C TxDOT
JOB
COUNTY
CONT SECT
DIST
REVISIONS HIGHWAY
SHEET NO.
TXDOT TXDOT TXDOT TXDOTAugust 1995
82
DENTON18\\HZDALLAS1\disk1\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.2 AutoCAD\TRAFFIC\Details100September 3, 2019
DENTON18September 3, 2019\\HZDALLAS1\disk1\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.2 AutoCAD\TRAFFIC\Details101
FED.RD.
DIV.NO.
STATE COUNTY
CONT.SECT.JOB HIGHWAY
SHEET
STATE
NO.
NO.
6
TEXAS3' - 6"INTEGRAL SIGN
DIST.
(SEE TITLE SHEET)
START CROSSING
DON'T START
If Started
Vehicles
Watch For
Finish Crossing
TIME REMAINING
DON'T CROSS
TO CROSS
PUSH BUTTON
To Finish Crossing
STEADY
TIMER
FLASHING
START CROSSING
DON'T START
If Started
Vehicles
Watch For
Finish Crossing
TIME REMAINING
DON'T CROSS
TO CROSS
PUSH BUTTON
To Finish Crossing
STEADY
TIMER
FLASHING
9" X 15"
SIGN R10-3eL
9" X 15"
SIGN R10-3eR
2
NOTES:
AWAY-FROM-TRAFFIC SIDE OF THE PEDESTAL OR MAST ARM POLE.
WITHIN THE SIGNAL MOUNTING HARDWARE.
DISPLAY THE SYMBOLIZED MESSAGES SHOWN ABOVE.
PEDESTAL POLE
PEDESTRIAN PUSH BUTTON POLE
PROJECT NO.4'6'TYPE
24-A
FOUNDATION
TYPE
24-A
FOUNDATION
18 DENTONPEDESTRIAN SIGNAL
SCREW ASSEMBLY
STAINLESS STEEL
GALVANIZED CABLE
PUSH
BUTTON
FOR
PEDESTRIAN SIGNAL HEAD MOUNTING
FOR ONE PEDESTRIAN SIGNAL HEAD
152A
PEDESTRIAN PUSHBUTTON
SIGN DETAILS
9" x 12"
PUSH
BUTTON
FOR
9" x 12"
PEDESTRIAN SIGNAL HEAD MOUNTING
FOR TWO PEDESTRIAN SIGNAL HEADS
143C
SIGN R10-4bL SIGN R10-4bR
PUSH
BUTTON
FOR
9" x 12"
SIGN R10-4bRL
SIGN DETAILS
2
COUNTDOWN PEDESTRIAN PUSHBUTTON
TYPE 1 CLAMP
1 ALTERNATIVE MOUNTING METHOD
2
ALTERNATIVE PEDESTRIAN SIGNAL
HEAD AND SIGNING
revised 12-92
revised 10-08
3
revised 01-11
NOTE:
REQUIREMENTS SHOWN ON THESE DRAWINGS
BE DEEMED ACCEPTABLE.
SHOWN AS AN EXAMPLE ONLY. POLES OF
AND ARE APPROVED BY THE ENGINEER WILL
SIMILAR DESIGN FOR ANY CROSS SECTION
WHICH MEET THE SPECIFICATIONS AND
THE POLES ON THIS DRAWING ARE
3
1
TYPE 1 CLAMP
AND BASE
PEDESTRIAN POLE
1" PVC
GROUND
TANK
PEDESTRIAN PUSH BUTTON POLE
GROUNDING DETAILS
PEDESTRIAN PUSH
BUTTON POLE
4
revised 09-15
4
PEDESTRIAN PUSH BUTTON POLE
GROUNDING DETAILS
CONDUCTOR
GROUNDING
EQUIPMENT
NO. 6 AWG
FOUNDATION
TYPE 24-A
6"6"2"-4"GROUND ROD
COPPER CLAD
5/8" X 8'
AS SHOWN IN THE PLANS
CONDUIT - SIZE/TYPE
037
CAP
3'-6"5'INTEGRAL SIGN
WITH
O.D.
4 •"
BASE
BREAKAWAY
ON PLANS
AS SHOWN
SIDEWALK
CONCRETE
3 APS UNIT
FOR
MOUNTING
DUAL APS
UNITS
ADAPTER
5
5
revised 06-17
APS UNIT ADDED
88 5
SIGN
R10-3eL
5
1. ALL PEDESTRIAN SIGNAL HEADS SHALL BE INSTALLED ON THE
2. ALL WIRING FOR PEDESTRIAN SIGNALS SHALL BE TOTALLY ENCLOSED
3. ALL PEDESTRIAN SIGNAL HEADS AND PUSH BUTTON SIGNS SHALL
5
5
8888
88
5
7'-0" MINIMUM - 10'-0" MAXIMUM5
MOUNTING HEIGHT REVISED
REVISED
MOUNTING HARDWARE NOTES
SIGNAL HEAD REMOVED
"SYMBOLS ONLY" PEDESTRIAN
AS REQUIRED
SIGN
R10-3eR
WITH
APS UNIT
5
APPROVED EQUAL.
OR McCAIN QUICKMOUNT OR
FOR CLAM SHELLS, USE ICC P/N 4805
USED AS APPROVED BY THE ENGINEER.
SHELL MOUNTING HARDWARE MAY BE
NOTE: EITHER TYPE 1 CLAMPS OR CLAM
1567 01 FM 720
HEAD DETAILS (DAL)
C TXDOT 2017
DALLAS DISTRICT STANDARD
September 3, 2019\\HZDALLAS1\disk1\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.2 AutoCAD\TRAFFIC\Details102
STOP LINE
TRAFFIC FLOW
(1-5 FT TYP)
SECOND SETBACK ZONES
(1-5 FT TYP)
FIRST SETBACK ZONES
(60-100 FT TYP FOR LEFT TURN LANES)
(40-100 FT TYP FOR THROUGH LANES)
STOP LINE ZONES
(MPH)
LIMIT
SPEED
APPROACH
45
50
55
60
565
485
405
245
300
325
355
380
410
(FT)
A
DISTANCE
(FT)
B
DISTANCE
65
70
RADAR DETECTION INSTALLATION DETAILS
DN:-CK:-DW:-CK:-EF
FED.RD.
DIV.NO.
STATE
JOB
COUNTY
FEDERAL AID PROJECT NO.
DISTRICT
CONTROL
SHEET
NO.
HIGHWAY
NO.
6
REVISIONS
Texas Department of Transportation
R
C Dallas District
DALLAS DISTRICT STANDARD
TRF-Aus.
SECTION
TEXAS 18 $CNTY
$JOB
(SEE TITLE SHEET)
$CONT $SECT
$HWY
RVDS-18 (DAL)
2018
EF---C TxDOT May 2018
360
445
525
DETECTION SYSTEM
RADAR VEHICLE
400
440
490
530
575
620
(LF)
DETECTION
RANGE OF
MINIMUMA
B
RADAR DETECTION ZONE LOCATIONS
MAY BE SUBMITTED FOR APPROVAL.
OR PRODUCT, AND ALTERNATE MOUNTING METHODS
INTENDED TO REPRESENT ANY SPECIFIC BRAND
2. THE RADAR DETECTOR UNITS SHOWN ARE NOT
LEFT, RIGHT, AND TO ROTATE.
MUST BE ADJUSTABLE TO TILT UP, DOWN,
1. THE RADAR SENSOR MOUNTING BRACKET
NOTES:
POLE MOUNT
SIGNAL MAST ARM POLE
RADAR BRACKET
RADAR DETECTOR
FIELD DRILL WITH GROMMET
CGB CONNECTION OR
RADAR CABLE
BANDING (2 PLACES MIN)
3/4" STAINLESS STEEL
MAST ARM MOUNT "A-A"SIGNAL MAST ARM
RADAR DETECTOR
DRIP LOOP
RADAR BRACKET
FIELD DRILL WITH GROMMET
CGB CONNECTION OR
BANDING (2 PLACES MIN)
3/4" STAINLESS STEEL
SECTION "A-A"
DRIP LOOP
SIGNAL MAST ARM
RADAR BRACKET
FIELD DRILL WITH GROMMET
CGB CONNECTION OR
RADAR DETECTOR
BANDING (2 PLACES MIN)
3/4" STAINLESS STEEL
SPAN WIRE MOUNT FOR ADVANCE RADAR
SADDLE CLAMP
JUNCTION BOX
SWAY CABLE
TETHER CABLE
UNIT
DETECTOR
RADAR
CABLE
MESSENGER
GROUND TO
MESSENGER CABLE
BRACKET
MOUNTING
SIGN
September 3, 2019\\HZDALLAS1\disk1\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.2 AutoCAD\TRAFFIC\Details103
SHEET
NO.
LIFT PLATE
THIMBLEYE BOLT (Angle Type)
EYE NUTS (Twineye & tripleye)
GUY CLAMP (3-Bolt)
8-WAY ANCHOR
COMPRESSION FITTING
CONNECTING LINK
GUY ATTACHMENT
3-WAY BAND
135
45
452Æ’"
DETAILS FOR STEEL
STRAIN POLES
STEEL STRAIN
POLE
SPAN CABLE ATTACHMENT
GUY ATTACHMENT
FOR 2 WIRES
CONNECTION
LINK
for 2 guy for 1 guy
wires wire
GUY ATTACHMENT
CONNECTION LINK
3 WAY
BAND
RELIABLE ELECTRIC
STRANDVISE (NO. 5202)
OR FARGO OR EQUAL
RAIN LOOP 6" MIN.SAG= 5% OFLENGTH OF SPANGUY
SPREADER
15" MIN.-48" MAX.
CONCRETE BACKFILL
*ANCHORS SHOULD BE LOCATED
BETWEEN THE ANCHOR AND THE
POLE BUTT IS EQUAL TO THE
DISTANCE FROM THE GROUND
TO THE POINT OF GUY
ATTACHMENT. IN NO CASE
SHOULD THE DISTANCE FROM
THE ANCHOR TO THE POLE
THE DISTANCE FROM THE
GROUND TO THE POINT OF
GUY ATTACHMENT.
SO THAT THE DISTANCE
3.5'
•" LIQUID
TIGHT FLEXIBLE
METAL CONDUIT
ENCLOSED 10" X 10" X 6"
NEMA 3R WITH TERMINAL
STRIP KULKA
PED. PUSH BUTTON SIGN
PED. PUSH BUTTON
GUY CLAMP OR
COMPRESSION FITTING
CONCRETE
BACKFILL
8-WAY ANCHOR
…" STRANDED STEEL CABLE
*
HOLE DIA = POLE DIA
AT BOTTOM + 18"
PVC MOULDING
COMPRESSION
FITTING
LIFT PLATE
THIMBLEYE BOLTMIN.
SQUARE WASHER
EYE NUT
COMPRESSION FITTING
…" STRANDED STEEL CABLE
EYE NUT
SQUARE WASHER
COMPRESSION FITTING
SPLIT BOLT CONNECTOR COMPRESSION
FITTING
LIFT PLATE
NO. 6 BARE
SQUARE WASHER
EYE NUT
COMPRESSION FITTING
THIMBLEYE BOLT
THIMBLEYE BOLT
SQUARE WASHER
AND NUT
MULTI CONDUCTOR
6" HEAVY GUY CLAMP WITH 3-5/8"
BOLTS OR RELIABLE ELECTRIC
GROUND
CONDUIT
(SEE LAYOUT SHEETS
FOR SIZE (PAY ITEM)
RELIABLE ELECTRIC NO.5264
FARGO NO. OR EQUAL
GROUND BOX
BACKFILL
CONCRETE
8"
CLASS A OR C
CLASS A OR C
…"X 8' DOUBLE
EYE ANCHOR ROD
CLASS A OR C
BUTT BE LESS THAN 1/3 OF
12" MAX.
STRANDVISE WITH FLEXIBLE BAIL
CONDUIT
(SEE LAYOUT SHEETS
FOR SIZE (PAY ITEM)
SOURCES:
SOURCES:
SOURCES:
SOURCES:
SOURCES:
FOR 1 WIRE
(CLASS 2)
40' SOUTHERN YELLOW PINE POLE
1•" LTFM (SUB 682)
(SUB 688)
7' MIN-
10' MAX.
LIFT PLATE
THIMBLEYE BOLT (Angle Type)
EYE NUTS (Twineye & tripleye)
GUY CLAMP (3-Bolt)
8-WAY ANCHOR
COMPRESSION FITTING
CONNECTING LINK
GUY ATTACHMENT
3-WAY BAND
135
45
452Æ’"
DETAILS FOR STEEL
STRAIN POLES
STEEL STRAIN
POLE
SPAN CABLE ATTACHMENT
GUY ATTACHMENT
FOR 2 WIRES
CONNECTION
LINK
for 2 guy for 1 guy
wires wire
GUY ATTACHMENT
CONNECTION LINK
3 WAY
BAND
RELIABLE ELECTRIC
STRANDVISE (NO. 5202)
OR FARGO OR EQUAL
RAIN LOOP 6" MIN.
GUY
SPREADER
15" MIN.-48" MAX.
CONCRETE BACKFILL
*ANCHORS SHOULD BE LOCATED
BETWEEN THE ANCHOR AND THE
POLE BUTT IS EQUAL TO THE
DISTANCE FROM THE GROUND
TO THE POINT OF GUY
ATTACHMENT. IN NO CASE
SHOULD THE DISTANCE FROM
THE ANCHOR TO THE POLE
THE DISTANCE FROM THE
GROUND TO THE POINT OF
GUY ATTACHMENT.
SO THAT THE DISTANCE
3.5'
•" LIQUID
TIGHT FLEXIBLE
METAL CONDUIT
ENCLOSED 10" X 10" X 6"
NEMA 3R WITH TERMINAL
STRIP KULKA
PED. PUSH BUTTON SIGN
PED. PUSH BUTTON
GUY CLAMP OR
COMPRESSION FITTING
CONCRETE
BACKFILL
8-WAY ANCHOR
…" STRANDED STEEL CABLE
*
PVC MOULDING
COMPRESSION
FITTING
LIFT PLATE
THIMBLEYE BOLTMIN.
SQUARE WASHER
EYE NUT
COMPRESSION FITTING
…" STRANDED STEEL CABLE
EYE NUT
SQUARE WASHER
COMPRESSION FITTING
SPLIT BOLT CONNECTOR COMPRESSION
FITTING
LIFT PLATE
NO. 6 BARE
SQUARE WASHER
EYE NUT
COMPRESSION FITTING
THIMBLEYE BOLT
THIMBLEYE BOLT
SQUARE WASHER
AND NUT
•" BLACK PLASTIC CABLE STRAPS OR
MESSENGER RINGS AT 12" CTRS.
6" HEAVY GUY CLAMP WITH 3-5/8"
BOLTS OR RELIABLE ELECTRIC
GROUND
CONDUIT
(SEE LAYOUT SHEETS
FOR SIZE (PAY ITEM)
RELIABLE ELECTRIC NO.5264
FARGO NO. OR EQUAL
GROUND BOX
BACKFILL
CONCRETE
8"
CLASS A OR C
CLASS A OR C
…"X 8' DOUBLE
EYE ANCHOR ROD
CLASS A OR C
BUTT BE LESS THAN 1/3 OF
12" MAX.
STRANDVISE WITH FLEXIBLE BAIL
CONDUIT
(SEE LAYOUT SHEETS
FOR SIZE (PAY ITEM)
SOURCES:
SOURCES:
SOURCES:
SOURCES:
SOURCES:
FOR 1 WIRE
(CLASS 2)
40' SOUTHERN YELLOW PINE POLE
1•" LTFM (SUB 682)
(SUB 688)
7' MIN-
10' MAX.
FED.RD.
DIV.NO.
STATE COUNTY
CONT.SECT.JOB HIGHWAY
SHEET
STATE
DIST.NO.
NO.
NO.
6
TEXAS
{ADDED AS REQUIRED.
ADDITIONAL THIMBLEYE BOLTS SHALL BE
TO SUPPORT MORE THAN 3 SAG SPANS.
EACH THIMBLEYE BOLT SHALL NOT BE USED
(SEE LAYOUT SHEETS)
(IF REQUIRED)
LUMINAIRES
RM CONDUIT FOR (SEE LAYOUT SHEETS)
VIVDS CABLE (IF REQUIRED)
RM CONDUIT FOR SSR OR
7'(50' POLE)
6'(40' POLE)PENTACHLOROPHENOL TREATED
R Y G
FEDERAL AID PROJECT NO.
DAL
‚" STRANDED STEEL CABLE
WIRE MOUNTED TRAFFIC SIGNALS
CONSTRUCTION DETAILS FOR SPAN
DALLAS DISTRICT STANDARD
HUBBELL POWER SYS. NO. 6560 (TWIN), 6510 (SINGLE)
MCLEAN POWER SYS. NO. J6515 (TWIN), J6510 (SINGLE)
OR EQUAL
HUBBELL POWER SYS. NO. 1283
MCLEAN POWER SYS. NO. J0283
OR EQUAL
OR EQUAL
HUBBELL POWER SYS. NO. 6460,
(NO. 5264), FARGO STRANDVISE,
HUBBELL POWER SYS. NO. 7898
MCLEAN POWER SYS. NO. J7890
OR EQUAL
HUBBELL POWER SYS. NO. 5016
MCLEAN POWER SYS. NO. J8154
OR EQUAL
SHEET 1 OF 3
(SEE TITLE SHEET)
$CNTY
$CONT $SECT $JOB $HWY
PEDESTRIAN SIGNAL
GROUND
ENTRY POINT
AT EACH CABLE
RAIN LOOP REQUIRED
SIGNAL CABLE
LUMINAIRE
ARM AND
FIXTURE
YELLOW
PLASTIC
GUY GUARD
September 3, 2019\\HZDALLAS1\disk1\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.2 AutoCAD\TRAFFIC\Details104
FED.RD.
DIV.NO.
STATE COUNTY
CONT.SECT.JOB HIGHWAY
SHEET
STATE
DIST.NO.
NO.
NO.
6
TEXAS
14
15
16
1718
19
20
21
22
9
4
3
2
1
5 6
7
8
9
5
10
11
12
13
TETHER ASSY
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
ITEM
1
1
1
1
1
1
1
1
1
6
6
2
2
2
1
8
4
2
6
2
1
1
QTY
CAP, EN-3/4, BLUE (FOR CGB)
NUT, HEX HD, Å "-18, STAINLESS
WASHER, SPLIT LOCK, Å ", STAINLESS
WASHER, FENDER, Å ", STAINLESS
PLATE, TETHER, 1-HOLE, ALUM
BOLT, HEX HD,Š"-18 X 1•", STAINLESS
BODY, 1•", HANGER, ALUM
SCREW, SET SQ HD, ‚"-20 X †", STAINLESS
NIPPLE, ALLTHREAD, 1•" NPS X 2.13", ALUM
BOLT, HEX HD,‚"-20 X 1•", GRADE 5, STAINLESS
WASHER, LOCK SPLIT, ‚", STAINLESS
WASHER, SLOTTED, ZINC 2
GASKET, TRI-BOLT, ˆ" X 70 DURO NEOPRENE
CAST ARM, FOR HORIZONTAL MOUNTED SIGNAL, ALUM
CGB,Æ’" .55-.65, ZINC 1
SCREW, SET SQ HD, Š"-18 X †", STAINLESS
TUBE CAP, 1•", PLASTIC
TUBE, 1•" X LENGTH, ALUM
SCREW, SET SQ HD, ‚"-20 X •", STAINLESS
TEE HORIZONTAL SLIP, DIE CAST ALUM
SPAN WIRE ADAPTER, ALUM W/ STAINLESS BUSHING
SPAN WIRE CLAMP, IRON, W/ U-BOLTS
DESCRIPTION
ASSEMBLY (BACKPLATE NOT SHOWN)
SIGNAL HEAD HARDWARE
BOTTOM TETHERED,SPAN WIRE
R Y Y G G
R Y G
R Y GR
PUSH
BUTTON
FOR
ONE-WAY
ADJUSTABLE FACE SIGNAL FOR
WOOD POLE MOUNTING
ADJUSTABLE FACE SIGNAL FOR
WOOD POLE MOUNTING
TWO-WAY
WITH ONE-PIECE REFLECTOR
SIGN DETAILS
SIGN R10-4bR
SIGN R10-4bL
LIQUID TIGHT
FLEXIBLE METAL
CONDUIT
FIVE WAY CONDUIT FITTING
POLE PLATE
PEDESTRIAN PUSHBUTTON
"EGGCRATE" VISOR PEDESTRIAN SIGNAL
PLAN VIEW
9"X12"
INSTALLATION
HORIZONTAL MOUNT
TYPICAL SPAN WIRE
INSTALLATION
HORIZONTAL MOUNT
TYPICAL SPAN WIRE
INSTALLATION
HORIZONTAL MOUNT
TYPICAL SPAN WIRE
TYPICAL
FLASHING BEACON
INSTALLATION
RAIN LOOP
TOP
R
Y
G
R R
Y Y
G G
SIDES
R
Y
R R
Y Y
G G
FRONT AND BACK
G
Y
RAIN LOOP
G
HARDW ARE KIT
FEDERAL AID PROJECT NO.
DAL
WIRE MOUNTED TRAFFIC SIGNALS
CONSTRUCTION DETAILS FOR SPAN
DALLAS DISTRICT STANDARD
SHEET 2 OF 3
H5LT
H4LT
H3
143C152A
143C
(SEE TITLE SHEET)
$CONT $SECT $JOB $HWY
$CNTYSeptember 3, 2019\\HZDALLAS1\disk1\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.2 AutoCAD\TRAFFIC\Details105
FED.RD.
DIV.NO.
STATE COUNTY
CONT.SECT.JOB HIGHWAY
SHEET
STATE
DIST.NO.
NO.
NO.
6
TEXAS
LEFT TURN
ON GREEN
YIELD
1"
3"
ALUMINUM RIVET
5" ALUMINUM COUPLING
6061-T6
MEDIUM EXTRUSION HPN053
SPAN WIRE CLAMP
SPAN WIRE CLAMP
EXTENDER
HANGER
ASSEMBLY
W/ 1" BOLTS
UNIDIRECTIONAL BOLT
HANGER ASSEMBLY DETAILS
R10-12
2. FOR STREET NAME SIGNS, EXTRUDED ALUMINUM
SPAN WIRE
CLAMP
NOTE: ALUMINUM RIVETS SHALL BE USED TO ATTACH
THE SIGN TO THE EXTRUDED ALUMINUM. SPACINGS
30" EXTENDER
ALUMINUM RIVET
OF RIVETS SHALL BE 6" O.C.
AS SHOWN.
SHALL BE MOUNTED FOR HORIZONTAL SUPPORT
UNIDIRECTIONAL BOLT
3"
R10-12
2. FOR STREET NAME SIGNS, EXTRUDED ALUMINUM
SPAN WIRE
CLAMP
NOTE: ALUMINUM RIVETS SHALL BE USED TO ATTACH
THE SIGN TO THE EXTRUDED ALUMINUM. SPACINGS
30" EXTENDER
ALUMINUM RIVET
OF RIVETS SHALL BE 6" O.C.
AS SHOWN.
SHALL BE MOUNTED FOR HORIZONTAL SUPPORT
UNIDIRECTIONAL BOLT
3"
FEDERAL AID PROJECT NO.
DAL
WIRE MOUNTED TRAFFIC SIGNALS
CONSTRUCTION DETAILS FOR SPAN
DALLAS DISTRICT STANDARD
>3'-0" UP TO 8'-0" - 2 SUPPORTS REQUIRED
SUPPORTS REQUIRED ARE AS FOLLOWS:
NOTES: 1. BASED ON SIGN WIDTH, THE NUMBER OF VERTICAL
3'-0" OR LESS - 1 SUPPORT REQUIRED
>8'-0" - 3 SUPPORTS REQUIRED
X
‚X •X ‚X
X
X1/6
1/3X 1/3X X1/6
SEE DIAGRAMS FOR SIGN SUPPORT SPACING
SHEET 3 OF 3
(SEE TITLE SHEET)
$CONT $SECT $JOB $HWY
$CNTYSeptember 3, 2019\\HZDALLAS1\disk1\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.2 AutoCAD\TRAFFIC\Details106
DENTONSeptember 3, 2019\\HZDALLAS1\disk1\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.2 AutoCAD\TRAFFIC\Details107
DENTONSeptember 3, 2019\\HZDALLAS1\disk1\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.2 AutoCAD\TRAFFIC\Details108
DENTONSeptember 3, 2019\\HZDALLAS1\disk1\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.2 AutoCAD\TRAFFIC\Details109
DN:CK:DW:CK:FILE:
JOB
COUNTY
SECT
DIST
REVISIONS
HIGHWAY
SHEET NO.
C TxDOTof this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:CONT
FILE:DATE:
Standard
Division
Operations
Traffic
ED(1)-14
71A
ed1-14.dgn
CONDUIT
A. MATERIALS
B. CONSTRUCTION METHODS
CONDUITS & NOTES
ELECTRICAL DETAILS
GENERAL NOTES FOR ALL ELECTRICAL WORK
AWG
16" x 16" x 4"
12" x 12" x 4"
10" x 10" x 4"
10" x 10" x 4"
#1
#2
#4
#6
#8
3 CONDUCTORS 5 CONDUCTORS 7 CONDUCTORS
4" x 12" x12"
4" x 8" x 8" 4" x 10" x10"
4" x 8" x8" 4" x 10" x10"
4" x 8" x8" 4" x 8" x8"
4" x 8" x8" 4" x 8" x8" 4" x 8" x8"
10" x 10" x 4"
No substitutions will be allowed for materials on this list.
listed on the MPL on TxDOT's website under "Roadway Illumination and Electrical Supplies."
Material Producers List (MPL) intended for use on each project. Prequalified materials are
6. When required by the Engineer, notify the Department in writing of materials from the
connectors, and bonding jumpers are subsidiary to the various bid items.
conductor. Provide stranded bare copper or green insulated grounding conductors. Ground rods,
conduits; metal poles; luminaires; and metal enclosures are bonded to the equipment grounding
5. Install grounding as shown on the plans and in accordance with the NEC. Ensure all metallic
request. Operate test equipment during inspection as requested by the Engineer.
calibrated within the last year. Provide calibration certification to the Engineer upon
tester, torque wrenches, and torque screwdrivers. Ensure all equipment has been properly
the contract and the NEC: voltmeter, ammeter, megohm meter (1000 volt DC), ground resistance
4. Provide the following test equipment as required by the Engineer to confirm compliance with
steel when plans specify galvanized, provided the bolt size is • in. or less in diameter.
3. Miscellaneous nuts, bolts and hardware, except for high strength bolts, may be stainless
additional cost to the Department.
is justification for rejection. Replace or reinstall rejected material or equipment at no
listing. Faulty fabrication or poor workmanship in any material, equipment, or installation
acceptable equal to a NEMA listed device. Acceptable devices may have both a NEMA and IEC
International Electrotechnical Commission (IEC) listed devices will not be considered an
LLC can be considered equivalent to UL. Where reference is made to NEMA listed devices,
as Canadian Standard Association (CSA), Intertek Testing Services NA Inc., or FM Approvals
Underwriters Laboratories (UL) or a Nationally Recognized Testing Lab (NRTL). NRTLs such
specifications, National Electrical Manufacturers Association (NEMA), and are listed by
the applicable articles of the National Electrical Code (NEC), TxDOT standards and
2. Provide new and unused materials. Ensure that all materials and installations comply with
diagrammatic and may be shifted to accommodate field conditions.
1. The location of all conduits, junction boxes, ground boxes, and electrical services is
October 2014
not applicable to the table, size junction boxes in accordance with NEC.
sizes is present, count the conductors as if all are of the larger size. For situations
through one conduit with no more than four conduits per box. When a mixture of conductor
the following table, which applies to the greatest number of conductors entering the box
3. Unless otherwise shown on the plans, provide junction boxes with a minimum size as shown in
Properly bond all metal conduits.
2. Provide galvanized steel RMC for all exposed conduits, unless otherwise shown on the plans.
called for on polyvinyl chloride (PVC) systems.
systems. Provide liquidtight flexible nonmetallic conduit (LFNC) when flexible conduit is
(LFMC) when flexible conduit is called for on galvanized steel rigid metallic conduit (RMC)
substitute other types of conduits for those shown. Provide liquidtight flexible metal conduit
Provide conduit types according to the descriptive code or as shown on the plans. Do not
conduits listed under Item 618 on the MPL under "Roadway Illumination and Electrical Supplies."
For Construction And Maintenance Of Highways, Streets, And Bridges," latest edition. Provide
Specification (DMS) 11030 "Conduit" and Item 618 "Conduit" of TxDOT's "Standard Specifications
1. Provide conduit, junction boxes, fittings, and hardware as per TxDOT Departmental Material
otherwise noted on the plans.
7. Provide PVC junction boxes intended for outdoor use on PVC conduit systems, unless
the same requirements for junction boxes used with RMC systems.
in accordance with the NEC. Provide junction boxes for IMC conduit systems that meet
use, unless otherwise noted on the plans. Size all galvanized steel junction boxes
junction boxes made from galvanized steel sheeting, listed and approved for outdoor
unless specifically required by the plan sheets. When EMT is called for, provide
6. Do not use intermediate metal conduit (IMC) or electrical metallic tubing (EMT)
aluminum boxes. Size outlet boxes according to the NEC.
junction boxes containing only 10 AWG or 12 AWG conductors. Do not use die cast
5. Provide hot dipped galvanized cast iron or sand cast aluminum outlet boxes for
an internal volume greater than 100 cu. inches.
conduit entries are on the same side. Mechanically secure all junction boxes with
conduit within 3 ft. of the enclosure or within 18 in. of the enclosure if all
purpose and supported by connection of two or more rigid metal conduits. Secure
entering raceways must have threaded entries or hubs identified for the intended
4. Junction boxes with an internal volume of less than 100 cu. in. and supported by
paint as an alternative for materials required to be galvanized.
as allowed under Item 445 "Galvanizing." Do not paint non-galvanized material with a zinc rich
more zinc content) to alleviate overspray. Use zinc rich paint to touch up galvanized material
cut ends of all mounting strut and RMC (threaded or non-threaded) with zinc rich paint (94% or
14. File smooth the cut ends of all mounting strut and conduit. Before installing, paint the field
conduit sealant.
tests. Do not use duct tape as a permanent conduit sealant. Do not use silicone caulk as a
the Engineer. Seal conduit immediately after completion of conductor installation and pull
13. Seal ends of all conduits with duct seal, expandable foam, or by other methods approved by
from the bottom of the box. See the ground box detail on sheet ED(4).
12. Place conduits entering ground boxes so that the conduit openings are between 3 in. and 6 in.
11. At all electrical services, install a 6 AWG solid copper grounding electrode conductor.
required, if the duct extends the full length through the casing.
grounding conductor. Bonding of conduit used as a casing under roadways for duct cable is not
or equipment grounding conductor. Ensure all bonding jumpers are the same size as the equipment
10. Install a bonding jumper from each grounding bushing to the nearest ground rod, grounding lug,
install a grounding type bushing on all metal conduit terminations.
9. Fit the ends of all PVC conduit terminations with bushings or bell end fittings. Provide and
tight sealing hubs are not required.
cans, service enclosures, auxiliary enclosures and junction boxes. Grounding bushings on water
hubs or using boxes with threaded bosses. This includes surface mounted safety switches, meter
8. Ensure conduit entry into the top of any enclosure is waterproof by installing conduit sealing
conduit and prove it clear in accordance with Item 618 prior to installing any conductors.
durable duct tape are allowed. Tightly fix the tape to the conduit opening. Clean out the
after installation to prevent entry of dirt, debris and animals. Temporary caps constructed of
7. During construction, temporarily cap or plug open ends of all conduit and raceways immediately
6. Provide and place warning tape approximately 10 in. above all trenched conduit as per Item 618.
Backfill", 402 "Trench Excavation Protection", and 403 "Temporary Special Shoring."
Items 110 "Excavation", 400 "Excavation and Backfill for Structures", 401 "Flowable
new roadways, backfill all trenches with cement-stabilized base as per requirements of
material unless otherwise noted on the plans. When placing conduit in the sub-base of
5. When placing conduit in the sub-grade of new roadways, backfill all trenches with excavated
or Box" prior to installing conduit or duct cable to prevent bending of the connections.
compact the bore pits below the conduit per Item 476 "Jacking, Boring, or Tunneling Pipe
driveways, sidewalks, or after the base or surfacing operation has begun. Backfill and
4. Unless otherwise shown on the plans, jack or bore conduit placed beneath existing roadways,
specifically in the plans or as approved by the Engineer.
3. Do not attach conduit supports directly to pre-stressed concrete beams except as shown
on ED(2). Install conduit support within 3 ft. of all enclosures and conduit terminations.
attaching metal conduit to surface of concrete structures. See "Conduit Mounting Options"
2. Space all conduit supports at maximum intervals of 5 ft. Install conduit spacers when
for the required expansion conduit fittings.
amount of expansion to the Engineer upon request. Do not use LFMC or LFNC as a substitute
movement at no additional cost to the Department. Provide the method of determining the
joint conduit fittings. Repair or replace expansion joint fittings that do not allow for
requested by the project Engineer, supply manufacturer's specification sheet for expansion
externally exposed on structures such as bridges at maximum intervals of 150 ft. When
and install expansion joint fittings on all continuous runs of galvanized steel RMC conduit
the structure's expansion joints to allow for movement of the conduit. In addition, provide
1. Provide and install expansion joint conduit fittings on all structure-mounted conduits at
the service riser conduit.
properly sized stainless steel or hot dipped galvanized one-hole standoff straps are allowed on
10. Use two-hole straps when supporting 2 in. and larger conduits. On electrical service poles,
foundations.
foundations. Provide PVC or galvanized steel RMC elbows as called for at all ground boxes and
and schedule as shown on the plans. Do not extend substituted conduit into ground boxes or
the HDPE conduit to PVC (or RMC elbow when required) at the bore pit. Provide conduit of the size
except that the conduit is supplied without factory-installed conductors. Make the transition of
size PVC called for in the plans. Ensure the substituted HDPE meets the requirements of Item 622,
conduit bid under Item 618. Ensure bored HDPE substituted for PVC is schedule 40 and of the same
the Engineer, substitute HDPE conduit with no conductors for bored schedule 40 or schedule 80 PVC
conductors according to Item 622 "Duct Cable." At the Contractor's request and with approval by
9. When required, provide High-Density Polyethylene (HDPE) conduit with factory installed internal
PVC elbows are subsidiary to various bid items.
concrete. PVC extensions are allowed on these concrete encased rigid metal elbows. RMC or
metal elbow is not required if the entire RMC elbow is encased in a minimum of 2 in. of
elbow by means of a grounding bushing on a rigid metal extension. Grounding of the rigid
the plans and any portion of the RMC elbow is buried less than 18 in., ground the RMC
the PVC conduit system. When galvanized steel RMC elbows are specifically called for in
a flat, high tensile strength polyester fiber pull tape for pulling conductors through
8. Provide PVC elbows in PVC conduit systems, unless otherwise shown on the plans. Use only
DENTON18September 3, 2019\\HZDALLAS1\disk1\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.2 AutoCAD\TRAFFIC\Details110
DN:CK:DW:CK:FILE:
JOB
COUNTY
SECT
DIST
REVISIONS
TxDOT TxDOT TxDOT TxDOT
HIGHWAY
SHEET NO.
C TxDOT
of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:CONT
FILE:DATE:Standard
Division
Operations
Traffic
ELECTRIC CONDUIT TO BRIDGE DECK ATTACHMENT
CONDUIT MOUNTING OPTIONS
71B
ED(2)-14
ed2-14.dgn
CONDUIT SUPPORTS
ELECTRICAL DETAILS
TYPICAL CONDUIT ENTRY TO BRIDGE STRUCTURE DETAIL
EXPANSION ANCHOR NOTES FOR BRIDGE DECK ATTACHMENT
See ED(1)B.2
Attachment to concrete surfaces
h
h
introduced after conduit installation.
at the required minimum embedment depth ( ef). No lateral loads shall be
breakout, and concrete pullout strengths as determined by ACI 318 Appendix D)
6. Use anchors of minimum 1600 Lbs tensile capacity (minimum of steel, concrete
thread length for proper torqueing and tightening of anchors.
embedment depth, ( ef), as shown. Increase ( ef)as needed to ensure sufficient
deck strands or reinforcement. Install anchors to ensure a minimum effective
5. Prior to hole drilling, use rebar locator to ensure clearing of existing
the structure.
be witnessed and approved by the Engineer prior to furnishing anchors on
demonstration test to evaluate the procedures and tools. The test shall
manufacturer's published installation instructions. Arrange a field
4. Install anchors as shown on the plans and in accordance with the anchor
wedge shall be stainless steel.
application in marine environment, both the anchor body and expansion
bodies can be either zinc-plated carbon steel or stainless steel. For
manufactured with carbon steel expansion wedges are not allowed. Anchor
3. Use anchors manufactured with stainless steel expansion wedges. Anchors
uncracked concrete.
list; and do not use expansion anchors that are only approved for use in
do not use expansion anchors that are not included in the ICC-ES approval
2. Unless otherwise approved by the Engineer: do not use adhesive anchors;
Anchors.
maintained on the ICC-ES website under Division 031600 for Concrete
ICC-ES Evaluation Report number, and its approval status shall be
Service (ICC-ES). The chosen anchor product shall have a designated
use in cracked concrete by the International Code Council, Evaluation
1. Use torque controlled mechanical expansion anchors that are approved for
h
HANGER ASSEMBLY DETAIL
1"
Æ’"
Bridge Deck
Hex Nut
Hex Nut
efh
Threaded Coupler Nut
Washer & Flat Washer
Hex Nut, Split Lock
Washer & Flat Washer
Hex Nut, Split Lock
Oversized Cut Washer
Washer & Square or
Hex Nut, Split Lock
Channel
Mounting
Conduit
Min.
=2 •"
Anchor
Expansion
…" Dia.
Rod
Threaded
…" Dia.
"SPAN"
less than 2'
2'-0" to 2'-6"
>2'-6" to 3'-0"
1 †" x 1 …"
"H"
"W"
12 Ga.
1 †" x 1 †"
1 †" x 2 ‹"
12 Ga.
12 Ga.
"W" x "H"
CONDUIT MOUNTING CHANNEL
"T"
"T"
capacity is not reduced by more than 15%.
patterns are allowed, if the load carrying
Channels with round or short slotted hole
Conduit (RMC)
Rigid Metal
Channel
Mounting
Conduit
CONDUIT HANGING DETAIL1'-3"6"
[ Girder [ Girder
Deck
Bridge
Min
1"
Min
ASSEMBLY DETAIL"
See "HANGER MaxVaries
Channel
Conduit Mounting
"SPAN"
Clamp
Conduit
Conduit (RMC)
Rigid Metal
[ …" Diameter
& Threaded Rods
Expansion Anchors
PVC
Conduit
Wing Wall
3' max.
RMC
Fitting
Expansion
Conduit
galvanized)
or equal) (Hot dip
Kindorf, Unistrut
Channel (B-line,
Conduit Mounting
Structure
Concrete
Conduit Strap
galvanized
or hot dipped
Stainless steel
Strut Type(mounting shoe)
Conduit Spacer
Structure
Concrete
Conduit min.1" conduit strap
malleable
galvanized
Hot-dipped
1 •" max.
depth 1" min.,
anchor. Anchor
to 2" use …" dia.
For conduits 1 •"
‚" dia. anchor.
up to 1 ‚" use
for conduit •"
expansion anchor:
Stainless steel Min. •"1 •" max.
depth 1" min.,
anchor. Anchor
steel expansion
…" Stainless
October 2014
DENTON18September 3, 2019\\HZDALLAS1\disk1\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.2 AutoCAD\TRAFFIC\Details111
DN:CK:DW:CK:FILE:
JOB
COUNTY
SECT
DIST
REVISIONS
TxDOT TxDOT TxDOT TxDOT
HIGHWAY
SHEET NO.of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:CONT
FILE:DATE:Standard
Division
Operations
Traffic
ED(3)-14
71C
ed3-14.dgn
CONDUCTORS
ELECTRICAL DETAILS
tape
adhesive
Hot melt
A. MATERIAL INFORMATION
ELECTRICAL CONDUCTORS
B. CONSTRUCTION METHODS
Tube
Shrink
Heat
type connector
"C" clamp
cover
insulating splice
with gel-filled
Listed Screw Type
molded cover
See through molded clamp
Snap-lock,
SPLICE OPTION 3
overlap
2" Min.
„" to ‚"
of tubing by
extend past end
tape. Tape to
hot melt adhesive
conductors with
Seal between
Compression Type
SPLICE OPTION 1
Split Bolt Type
SPLICE OPTION 2
overlap
2" Min.
tape
adhesive
Hot melt
„" to ‚"
of tubing by
extend past end
tape. Tape to
hot melt adhesive
conductors with
Seal between
sharp edges
heat shrink from
tape to protect
hot melt adhesive
connector with
Wrap split bolt
Tube
Shrink
Heat
overlap
2" Min.
Split bolt
overlap
2" Min.
„" to ‚"
tubing by
past end of
Tape to extend
adhesive tape.
hot melt
diameter with
insulation
Increase
„" to ‚"
tubing by
past end of
Tape to extend
adhesive tape.
hot melt
diameter with
insulation
Increase
connections
for making
Set Screw/Lug
C. TEMPORARY WIRING
GROUND RODS & GROUNDING ELECTRODES
A. MATERIAL INFORMATION
B. CONSTRUCTION METHODS
the NEC.
during the construction process in a timely manner and in conformance with
5. Protect and when necessary repair any existing electrical conduits uncovered
conformance with the NEC.
lowest point. Ground messenger wires that support power conductors in
the vertical clearance to ground is at least 18 ft. when measured at the
in areas subject to vehicle traffic or mobile construction equipment, ensure
horizontally from any metal structure. Where installing temporary conductors
the splices are more than 10 ft. above grade vertically and more than 5 ft.
4. Enclose conductor splices within a listed enclosure or ground box, or ensure
where approved.
3. Use listed wire nuts with factory applied sealant for temporary wiring
following: molded cord and plug set, receptacle, or circuit breaker type.
and refrigerators located outdoors at grade. GFCI may be any one of the
portable electrical equipment, power tools, ice machines, ice storage bins
2. Provide a ground fault circuit interrupter (GFCI) for power outlets for
the NEC article "Temporary Installations" and Department standard sheets.
1. Install temporary conductors and electrical equipment in accordance with
Listed Screw Type
horizontal trench for rocky soil or a solid rock bottom.
7. Written authorization is required before installing a ground rod in a
and properly sized bonding jumper on each end of the metal conduit.
conductors with metal conduit, provide and install a grounding type bushing
conductors with non-metallic conduit. When protecting grounding electrode
6. Unless otherwise called for in the plans, protect grounding electrode
radius bend of four inches for these conductors.
lightning protection ground rods. When a bend is required, ensure a minimum
5. Route all conductors as short and straight as possible for connection to
at the clamp location.
4. Remove all non-conductive coatings such as concrete splatter from the rod
the rod.
3. Install ground rods so the imprinted part number is at the upper end of
2. Do not place ground rods in the same drilled hole as a timber pole.
soil, ensure that the upper end is between 2 to 4 in. below finished grade.
readily accessible for inspection or repairs. For ground rods installed in
in concrete, ensure the connection of the conductor to the ground rod is
concrete, or both, as called for in the plans. For ground rods installed
1. Furnish auxiliary ground rods for lightning protection and install in soil,
under Item 620.
installations, provide a minimum size 8 AWG EGC. The EGC is paid for
are bonded together at every accessible location. For traffic signal
current carrying conductor contained in the conduit. Ensure all EGCs
Unless shown elsewhere, size the EGC to be the same size as the largest
(EGC) in all conduits that contain circuit wiring of 50 volts or more.
12. Provide and install a separate stranded equipment grounding conductor
October 2014C TxDOT
subsidiary to various bid items.
materials, breakaway disconnects, splice covers, and fuse holders are
UL listed gel-filled insulating splice covers. Splicing materials, insulating
adhesive tape to fill the gap and seal the ends of heat shrink tubing. Provide
split bolt connectors for splicing as specified in DMS 11040. Use hot melt
4. Use listed compression or screw type pressure connectors, terminal blocks, or
with a permanent marker.
identification as shown in the plans. Print circuit identification on the tag
two straps, large enough to indicate circuit number, letter, or other
around both circuit conductors at each accessible location. Provide tags with
identify the conductors of each branch circuit by attaching a non-metallic tag
3. Where two or more circuits are present in one conduit or enclosure, permanently
plans.
electrode conductor to the concrete encased grounding electrode as shown in the
with a UL listed connector in accordance with DMS 11040. Connect the grounding
the service location. Connect the grounding electrode conductor to the ground rod
service equipment to the concrete encased grounding electrode or the ground rod at
2. Provide a solid copper 6 AWG grounding electrode conductor to bond the electrical
least 6 in. of the conductor's insulation with half laps of tape.
jacket or by colored tape. When identifying conductors with colored tape, mark at
color jacket. Identify electrical conductors 4 AWG and larger by continuous color
system. Identify conductors 6 American Wire Gauge (AWG) and smaller by continuous
except green, white, or gray. Keep color scheme consistent throughout the wiring
or bare conductors. Identify ungrounded (hot) conductors with any color insulation
white insulation. Identify grounding conductors (ground wires) with green insulation
conductors in conformance with the NEC. Identify grounded (neutral) conductors with
under "Roadway Illumination and Electrical Supplies" Item 620. Color code insulated
conductors as listed on the Material Producers List (MPL) on the Department web site
Specification (DMS)11040 "Conductors" and Item 620 "Electrical Conductors." Provide
1. Provide Type XHHW insulated conductors in accordance with Departmental Material
as shown on the MPL.
openings. Leave unused openings factory sealed. Use prequalified breakaway connectors
a single opening in a boot. Provide waterproof boots with the correct number of
around the conductor to ensure waterproof connection. Only one conductor may enter
breakaway devices. Trim waterproofing boots on breakaway connectors to fit snugly
threaded connections. Proper terminations are critical to the safe operation of
instructions when terminating conductors to breakaway connectors. Properly torque
conductors pass through a breakaway support device. Follow manufacturer's
11. Install breakaway connectors on conductors bid under Item 620 whenever those
listing for maximum number and size of conductors allowed.
connector is rated for multiple conductors. Do not exceed the pressure connector's
10. Do not terminate more than one conductor under a single connector, unless the
Use only approved splicing methods.
9. Do not repair damaged conductors with duct tape, electrical tape, or wire nuts.
insulation resistance test at no additional cost to the department.
8. Replace conductors and cables that are damaged beyond repair or that fail an
conductor strands or removed strands will be considered damaged.
nicking the individual strands of the conductor. Conductors with nicked individual
7. When terminating conductors, remove the insulation and jacketing material without
6. Support conductors in illumination poles with a J-hook at the top of the pole.
accumulation of water.
ground boxes. Install wire nuts in an upright position to prevent the
smaller conductors in above ground junction boxes, but not in pole bases or
5. Wire nuts with factory applied waterproof sealant may be used for 8 AWG or
manufacturer's specifications when used in place of heat shrink tubing.
4. Size and install gel-filled insulating splice covers according to
been burned, or overheated, is considered defective and must be replaced.
seal the ends of heat shrink tubing. Heat shrink tubing that appears to have
past the heat shrink tubing. Use hot melt adhesive tape to fill the gap and
the individual conductors and the heat shrink tubing. Ensure the tape extends
insulation using hot melt adhesive tape to provide a watertight seal between
conductors, prior to heating the tubing, increase the diameter of the conductor
may not shrink sufficiently to provide a watertight seal around the individual
minimum of 2 in. past both sides of the splice. Where heat shrink tubing
watertight splice. Overlap conductor insulation with heat shrink tubing a
heat shrink tubing or gel-filled insulating splice covers to provide a
terminal blocks, or split bolt connectors. Insulate splices with heavy wall
enclosures and use only listed compression or screw type pressure connectors,
3. Make splices only in junction boxes, ground boxes, pole bases, or electrical
length of conductor at enclosures, weatherheads and pole bases.
boxes when pulled through with no splice. Leave 1 ft. minimum, 1.5 ft. maximum
ground boxes. Leave 3 ft. minimum, 4 ft. maximum length of conductor in ground
2. Leave 2 ft. minimum, 3 ft. maximum length for each conductor up to the splice in
Engineer to witness the tests.
insulation resistance tests in accordance with Item 620. Coordinate with the
needed alterations or repairs at no additional cost to the department. Perform
perform conductor pull test. If a conductor cannot be freely pulled, make any
conductors through the conduit system. After installing conductors in conduit,
1. Use only a flat, high tensile strength polyester fiber pull tape for pulling
specific locations including electrical service, see individual plan sheets.
plans sheets. Concrete encased grounding electrodes may be called for in
length rods may be called for in some specific locations, see the individual
ground rods according to DMS 11040 and the plans. Larger diameter or longer
1. Provide and install a grounding electrode at electrical services. Provide
DENTON18September 3, 2019\\HZDALLAS1\disk1\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.2 AutoCAD\TRAFFIC\Details112
DN:CK:DW:CK:FILE:
JOB
COUNTY
SECT
DIST
REVISIONS
TxDOT TxDOT TxDOT TxDOT
HIGHWAY
SHEET NO.
C TxDOT
of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:CONT
FILE:DATE:Standard
Division
Operations
Traffic
ED(4)-14
71D
ed4-14.dgn
GROUND BOXES
ELECTRICAL DETAILS
GROUND BOXES
APRON FOR GROUND BOX
PLAN VIEW
AA
(1)
SECTION A - A
3" to 6"
2"2"
10"(typ)
box
Ground
steel
Reinforcing
No. 3
duct cable
Conduit or
steel
Reinforcing
No.3
box
Ground
(typ)
10"Depth of box
Apron-Full
(typ)
10"
ell
Conduit
(when required)
Concrete Apron
Class A
PVC (4)
fitting for
RMC. Bell end
bushing for
Grounding
(2)
fill (3)
9" Aggregate
B. CONSTRUCTION METHODS
4. Provide larger ground boxes in accordance with Item 624 and as shown in the plans.
3. Ensure ground box cover is correctly labeled in accordance with DMS 11070.
and Electrical Supplies," Item 624.
the Material Producers List (MPL) on the Department web site under "Roadway Illumination
2. Provide Type A, B, C, D, and E ground boxes as shown in the plans, and as listed on
Item 624 "Ground Boxes."
accordance with Departmental Material Specification (DMS) 11070 "Ground Boxes" and
1. Provide polymer concrete ground boxes measuring 16x30x24 in. (WxLxD) or smaller in
GROUND BOX COVER
L
J K
H
I
P
PLAN VIEW SIDEEND
M
Nfor head
recess
bolt with
Hole for •"
See DMS 11070
requirements.
and labeling
For cover logo
GROUND BOX DIMENSIONS
TYPE
A
B
C
D
E
GROUND BOX COVER DIMENSIONS
DIMENSIONS (INCHES)
H I N PJKLM
23 13 ƒ13 •
30 •30 ‚17 •13 ‚17 ‚
2
2
23 ‚9 ‡5 „
6 Æ’
1 …
1 …
A, B & E
C & D
TYPE
October 2014
OUTSIDE DIMENSIONS (INCHES)
12 X 23 X 11
12 X 23 X 22
(Width x Length X Depth)
16 X 29 X 11
16 X 29 X 22
12 X 23 X 17
conduits terminating in a ground box.
the ground box. Install a PVC bushing or bell end fitting on the upper end of all PVC
Ground RMC elbows when any part of the elbow is less than 18 in. below the bottom of
(4) Install a grounding bushing on the upper end of all RMC terminating in a ground box.
interior volume of the box.
(3) Place aggregate under the box, not in the box. Aggregate should not encroach on the
(2) Maintain sufficient space between conduits to allow for proper installation of bushing.
or bell end fittings.
that ground box walls do not interfere with the installation of grounding bushings
(1) Uniformly space ends of conduits within the ground box. Position ends of conduits so
A. MATERIALS
11. Bond metal ground box covers to the grounding conductor with a tank ground type lug.
identifying the specific boxes in writing. This work will be paid for separately.
of the contract, the Engineer may direct the Contractor to bond the metal covers,
10. If other ground boxes with metal covers are within the project limits but are not part
fully describing the work required.
Verify existing ground boxes with metal covers are shown on the plans, with notes
as the grounding conductor. The bonding jumper is subsidiary to various bid items.
equipment grounding conductor with a 3 ft. long stranded bonding jumper the same size
9. If an existing ground box in the contract has a metal cover, bond the cover to the
below grade.
to cut an appropriately sized hole for conduit entry in the side wall at least 18 inches
8. When a type B or D ground box is stacked to meet volume requirements, it is allowable
together and to the ground rod with listed connectors.
7. When a ground rod is present in a ground box, bond all equipment grounding conductors
Do not use silicone caulk as a sealant.
foam, or other method as approved. Do not use duct tape as a permanent conduit sealant.
and pull tests. Permanently seal the ends of all conduits with duct seal, expandable
6. Permanently seal conduits immediately after the completion of conductor installation
5. Temporarily seal all conduits in the ground box until conductors are installed.
conduits so grounding bushings and bell end fittings can easily be installed.
4. Install all conduits and ells in a neat and workmanlike manner. Uniformly space
boxes.
3. Keep bolt holes in the box clear of dirt. Bolt covers down when not working in ground
subsidiary to ground boxes when called for by descriptive code.
under the box. Ground box aprons, including concrete and reinforcing steel, are
of concrete for the apron extends from finished grade to the top of the aggregate bed
2. Cast ground box aprons in place. Reinforcing steel may be field bent. Ensure the depth
aggregate.
least 9 inches deep, prior to setting the ground box. Install ground box on top of
Item 302 "Aggregates for Surface Treatments." Ensure aggregate bed is in place and at
and setting ground box. Provide Grade 3 or 4 coarse aggregate as shown on Table 2 of
1. Remove all gravel and dirt from conduit. Cap all conduits prior to placing aggregate
DENTON18September 3, 2019\\HZDALLAS1\disk1\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.2 AutoCAD\TRAFFIC\Details113
DN:CK:DW:CK:FILE:
JOB
COUNTY
SECT
DIST
REVISIONS
TxDOT TxDOT TxDOT TxDOT
HIGHWAY
SHEET NO.
C TxDOT
of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:CONT
FILE:DATE:Standard
Division
Operations
Traffic
71E
ED(5)-14
ed5-14.dgn
ELECTRICAL SERVICES NOTES
SERVICE NOTES & DATA
ELECTRICAL DETAILS
TOP MOUNTED PHOTOCELL
or equal)
Kindorf, B-line
channel(Unistrut,
Conduit mounting
6"
and photocell
receptacle
photocell
Standard 3-prong
cell and pole.
between photo-
to 1" clearance
to provide •"
Conduit, bend
•" RM
utility company.
as allowed by
by Engineer, and
or as directed
finished grade
to 20 feet above
the pole or 18
from the top of
6" to 8" measured
Mount Photocell
Support
Service
of pole photocells as shown on Top Mounted Photocell Detail.
operation. Mount photocell facing north when practical. Mount top
photocell from stray or ambient night time light to ensure proper
1.Provide photocell as listed on the MPL. Move, adjust, or shield the
3/#2 2P/100 28.1N/A
ID
Service
Elec.
SB 183
Number
Sheet
Plan
No./Size
Conductors
Service
Amps
Switch
Safety
Pole/Amps
Ckt. Bkr.
Main
Amps
Contractor
Two-Pole
Amp Rating
Loadcenter
Panelbd/
ID
Circuit
Branch
Pole/Amps
Ckt. Bkr.
Branch
Amps
Circuit
Branch
Load
KVA
262P/40Lighting NB
Lighting SB
Underpass
Sig. Controller
Luminaires
Flashing Beacon 1
Flashing Beacon 2
252P/40
151P/20
231P/30
1P/20
1P/20
100
70
100
N/A
30
2P/60N/A
N/A
3/#6
3/#6
1 ‚"
1 ‚"
289
30
58
NB Access
2nd & Main N/A
ELECTRICAL SERVICE DATA
5.3
ELC SRV TY A 240/480 100(SS)AL(E)SF(U)
ELC SRV TY D 120/240 060(NS)SS(E)TS(O)
ELC SRV TY T 120/240 000(NS)GS(N)SP(O)
*
*
Electrical Service Description
documentation from the electric utility provider to the Engineer.
breaker's ampere interrupting capacity (AIC) rating and provide
verify that the available fault current is less than the circuit
2.When the utility company provides a transformer larger than 50 KVA,
ensure handle is lockable in both the "On" and "Off" positions.
1.Field drill flange-mounted remote operator handle if needed, to
* *
* Size
Conduit
Service
*
2"100
CCTV
2P/20
1P/20
9
3
4
4
October 2014
with a conduit sealing hub or threaded boss, such as a meter base hub.
Grounding bushings are not required when the end of the metal conduit is fitted
bushings on all metal conduits, and terminate bonding jumpers to grounding bus.
penetrate the equipment mounting panel inside the enclosure. Provide grounding
15.Do not install conduit in the back wall of a service enclosure where it would
enclosure that has no door pocket.
drawings before completion of the work to the Engineer, instead of placing in
11 in. x 17 in. plan sheets to 8 • in. x 11 in before laminating. Deliver these
sheets detailing equipment and branch circuits supplied by that service. Reduce
14.When providing an "Off The Shelf" Type D or Type T service, provide laminated plan
sheets, the installing contractor is to redline plan sheets before laminating.
8 • in. x 11 in. before laminating. If the installation differs from the plan
in the service enclosure's document pocket. Reduce 11 in. x 17 in. plan sheets to
branch circuits supplied by that service. The laminated plan sheets are to be placed
will copy and laminate the actual project plan sheets detailing all equipment and
used to build the enclosure in the enclosure's data pocket. The installing contractor
drawings and the laminated plan sheet showing the electrical service data chart
service. Before shipment to the job site, place the applicable laminated schematic
enclosure manufacturers will prepare and submit a schematic drawing unique to each
13.For all electrical service enclosures listed under Item 628 on the MPL, the UL 508
company specifications.
12.Ensure all mounting hardware and installation details of services conform to utility
movement demonstrated to the satisfaction of the Engineer.
required on all installed conductors, with at least six inches of free conductor
conductor. Ensure any bend in LFMC never exceeds 180 degrees. A pull test is
terminated with a grounding fitting. The LFMC must contain a grounded (neutral)
need not be strapped. Each end of LFMC must have a grounding bushing or be
length. Strap LFMC within 1 foot of each end. LFMC less than 12 inches in length
LFMC the same size as service entrance conduit. LFMC must not exceed 3 feet in
service enclosure when they are mounted 90 to 180 degrees to each other. Size the
11.Use of liquidtight flexible metal conduit (LFMC) is allowed between the meter and
grounding bushing on the RMC where it terminates in the service enclosure.
the conduit shown on the layout for that particular branch circuit. Install a
a minimum of 6 inches underground and then couple to the type and schedule of
on the layout sheets for branch circuit conduit. Extend all rigid metal conduits
conduit for branch circuit entry to enclosure is the same size as that shown
conductor. Size the service entrance conduit as shown in the plans. Ensure
• in. PVC conduit containing the electrical service grounding electrode
10.Provide rigid metal conduit (RMC) for all conduits on service, except for the
when furnished by the Contractor, will be paid for separately.
the elbow, including service conduit and conductors for the utility pole riser
service. For an underground utility feed, all service conduit and conductors after
including the riser or the elbow below ground are subsidiary to the electrical
9.All electrical service conduit and conductors attached to the electrical service
12 inches minimum, 18 inches maximum, or as required by utility.
weatherhead. The lengths of the conductors outside the weatherhead are to be
entrance conductor exits through a separately bushed non-metallic opening in the
with half laps of colored tape, when identifying conductors. Ensure each service
jacket or by colored tape. Mark at least 6 inches of the conductor's insulation
Identify electrical conductors sized 4 AWG and larger by continuous color
Wire Gauge (AWG). Identify size 6 AWG conductors by continuous color jacket.
and white colored XHHW service entrance conductors of minimum size 6 American
8.Provide wiring and electrical components rated for 75°C. Provide red, black,
stainless steel may be used.
7.When galvanized is specified for nuts, screws, bolts or miscellaneous hardware,
incidental contact as required by the NEC.
enclosure do not need a dead front trim. Protect incoming line terminations from
6.Enclosures with external disconnects that de-energize all equipment inside the
locks are installed.
Unless otherwise approved, do not energize electrical service equipment until
enclosures. Master Lock #2195 keys and locks become property of the State.
provide Master Lock #2195 Type 2 with brass tumblers for "off the shelf"
keyed #2195 for all custom electrical enclosures. Installing Contractor is to
5.The enclosure manufacturer will provide Master Lock Type 2 with brass tumblers
work as approved.
with the utility provider to determine costs and requirements, and coordinate the
with these charges prior to engaging the utility company to do the work. Consult
are paid for in accordance with Item 628. Get approval for the costs associated
charges, and other charges by the utility company to provide power to the location
with utility requirements. Primary line extensions, connection charges, meter
4.Coordinate with the Engineer and the utility provider for metering and compliance
complete electrical service as specified in the plans.
3.Provide all work, materials, services, and any incidentals needed to install a
detailed on the plans.
Illumination and Electrical Supplies," Item 628. Provide other service types as
on the Material Producers List (MPL) on the Department web site under "Roadway
Standard Specifications. Provide electrical service types A, C, and D, as listed
"Electrical Services-Pedestal (PS)", and Item 628 "Electrical Services" of the
"Electrical Services-Type D," DMS 11084 "Electrical Services-Type T," DMS 11085
"Electrical Services-Type A," DMS 11082 "Electrical Services-Type C," DMS 11083
Departmental Material Specification (DMS) 11080 "Electrical Services,"DMS 11081
2.Provide electrical services in accordance with Electrical Details standard sheets,
and guarantees as a customary trade practice, furnish these to the State.
or installation is justification for rejection. Where manufacturers provide warranties
Data chart in the plans. Faulty fabrication or poor workmanship in material, equipment,
circuit breaker panels, and branch circuit breakers as shown on the Electrical Service
Provide and install electrical service conduits, conductors, disconnects, contactors,
Association (NEMA) standards. Ensure material is Underwriters Laboratories (UL) listed.
provisions of the National Electrical Code (NEC) and National Electrical Manufacturers
1.Provide new materials. Ensure installation and materials comply with the applicable
in the PS descriptive code, provide an AL enclosure.
DMS 11080 and 11085. Do not provide GS pedestal services. If GS is shown
4.Provide pedestal service (PS) enclosures in accordance with ED(9) and
not paint stainless steel.
and D in accordance with DMS 11080, 11081, 11082, 11083, and 11084. Do
3.Provide aluminum (AL) and stainless steel (SS) enclosures for Types A, C,
DMS 11080, 11082, 11083, and 11084.
photocell or lighting contactor. Provide GS enclosures in accordance with
and for Type D and T services that do not use an enclosure mounted
2.Type galvanized steel (GS) enclosures may be used for Type C panelboards
1.Provide threaded hub for all conduit entries into the top of enclosure.
1.0
requirements. Ensure conduit size meets the National ELectrical Code.
Verify service conduit size with utility. Size may change due to utility meter
electrical service data chart specific to that service as shown in the plans.
Example only, not for construction. All new electrical services must have
box with cover.
aluminum outlet
or sand cast
cast iron,
galvanized,
Hot dipped
Schematic Type
Enclosure Type
Photocell Mounting Location
Service Support Type
Service Voltage V / V
ELEC SERV TY X XXX/XXX XXX (XX) XX (X) XX (X)
EXPLANATION OF ELECTRICAL SERVICE DESCRIPTIVE CODE
Typically Type T
000 indicates main lug only/
Disconnect Amp Rating
Meter-Check with Utility
(NS)= No safety Switch Ahead of
Meter-Check with Utility
(SS)= Safety Switch Ahead of
AL= Aluminum (Custom Enclosure)See MPL
SS= Stainless steel(Custom Enclosure)See MPL
GS= Galvanized steel("off the shelf")
Lighting Contactor Required
(N)= None/No Photocell or
(L)= Luminaire mounted
(T)= Top of pole
Mounted
(E)= Inside Service/Enclosure
from Utility
U= Underground Service Feed
from Utility
O= Overhead Service Feed
PS= Pedestal Service
signal pole
TS= Service on traffic
EX= Existing pole
for separately
OT= Pole by others or paid
SF= Steel frame
SP= Steel pole
TP= Timber pole
OC= Other concrete
GC= Granite concrete
between straps supporting conduit.
from box. 5 foot maximum spacing
Install conduit strap maximum 3 feet
SERVICE ASSEMBLY ENCLOSURE MAIN DISCONNECT & BRANCH CIRCUIT BREAKERS
PHOTOELECTRIC CONTROL
DENTON18September 3, 2019\\HZDALLAS1\disk1\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.2 AutoCAD\TRAFFIC\Details114
DN:CK:DW:CK:FILE:
JOB
COUNTY
SECT
DIST
REVISIONS
TxDOT TxDOT TxDOT TxDOT
HIGHWAY
SHEET NO.
C TxDOT
CONT
FILE:DATE:Standard
Division
Operations
Traffic
ED(7)-14
ed7-14.dgn
TYPES SF & SP
SERVICE SUPPORT
ELECTRICAL DETAILS
WITHOUT SAFETY SWITCH
PVCRMC
2"
SERVICE SUPPORT TYPE SP (O) - OVERHEAD SERVICE
of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:SERVICE SUPPORT TYPE SF & SP
joint material
•" expansion
pitch (typ.)
and #2 spiral at 6"
reinforcing bars
foundation 4-#5
24" dia. X 60"
utility
RMC to
(typ.) at 6" pitch
and #2 spiral
reinforcing bars
foundation 4-#5
24" dia. x 36" depth
TOP VIEW
Inset A
Inset A
HOOKED ANCHOR DETAIL
Inset B
Inset B
4"
max.
3'
INSET B
See Note 4
INSET A
71GMin.18"Rebar
Bolt
Anchor
Length
Hook
equipment
to accommodate
wide as required
install only as
Dimension varies,
wire mesh)
6" X 6" #6
concrete and
pad (class C
concrete
5" thick
‰"
radius
•"
POLE TOP PLATE 5" TYP.2 •" TYP.
TYP.
2 - places
for galv.
Drain hole
Meter
Enclosure
Service
WITHOUT SAFETY SWITCH
Inset A
20"
min.
2"
METER
RMC
5"
WITH SAFETY SWITCH
Inset A
Inset B
Inset B
at 6" pitch (typ.)
bars and #2 spiral
4-#5 reinforcing
foundation
24" dia. x 48"
ENCLOSURE
SERVICE
ENCLOSURE
SERVICE
equipment
securely mount
as needed to
Number of struts
equipment.
for mounting
Channel Strut
FRONT VIEW
Varies
SAFETY
SWITCH
max.
grade
above
72"Min.18"Min.18"WITH SAFETY SWITCH
concrete
Class "C"
(typ.) at 6" pitch
bars and #2 spiral
4-#5 reinforcing
depth foundation
24 Dia. x 60"
Inset A
60" TYP.Min.18"Inset B
SERVICE SUPPORT TYPE SF(U) - UNDERGROUND SERVICE SERVICE SUPPORT TYPE SP(U) - UNDERGROUND SERVICE
SUPPORT TYPE STEEL POLE (SP) AND STEEL FRAME (SF)(See Note 3)Switch
Safety
Meter
weatherhead.
conductor exits
white tape where
insulation with
conductor's
of neutral
or color code 6"
White insulation
18" max.
length, 12" min.,
Conductor slack
the weatherhead.
conductor exits
red tape where
insulation with
conductor's
or Line 2
length of Line 1
or color code 6"
Red insulation
Enclosure
Service
FRONT VIEW
WITH SAFETY SWITCH
18" max.
length, 12" min.,
Conductor slack
the weatherhead.
conductor exits
red tape where
insulation with
conductor's
or Line 2
length of Line 1
or color code 6"
Red insulation
weatherhead.
conductor exits
white tape where
insulation with
conductor's
of neutral
or color code 6"
White insulation
RMC
See Note 7.
electrode conductor.
service grounding
connect electrical
tank ground fitting,
•" X 13 UNC. Install
Drill, top, and thread
October 2014
(Verify with utility)
above grade.
socket 60" typical
Center of meter
elsewhere or directed by the Engineer.
11.Shop drawings are not required for service support structure unless specifically stated
prevent abrasion of the insulated conductors.
10.Avoid contact of the service drop and service entrance conductors with the metal pole to
wrench tight.
minimum size 6 AWG stranded copper bonding jumpers. Make up all threaded bonding connections
conductive material at contact points. Terminate bonding jumpers with listed devices. Install
9.Provide ‚" - 20 machine screws for bonding. Do not use sheet metal screws. Remove all non-
a tapped hole.
8.If Steel pole or frame is painted, bond each separate painted piece with a bonding jumper attached to
is fitted into a sealing hub or threaded boss.
grounding bushings where RMC terminates in the enclosure. Grounding bushings are not required when RMC
elbow, and then connect the schedule type and size of conduit shown in the plans. Provide and install
underground conduit runs from the electrical service, extend RMC from the service enclosure to an RMC
more information. Size service entrance conduit and branch circuit conduit as shown in the plans. For
electrode conductor to the tank ground fitting. See steel frame and steel pole details and Inset A for
conduit or tubing from the enclosure to the steel frame post. Connect electrical service grounding
tank ground fitting on steel frame post. Install service grounding electrode conductor in a non-metallic
from the enclosure to the tank ground fitting. For steel frame service supports, provide and install
conductor. Ensure electrical service grounding electrode conductor is as short and straight as possible
Provide properly sized hole through the bottom of the enclosure for the service grounding electrode
supports, provide and install tank ground fitting 4 in. to 6 in. below electrical service enclosure.
7.Drill and tap steel poles and frames for • in. X 13 UNC tank ground fitting. For steel pole service
unobstructed concrete cover.
6.Use class C concrete for foundations. Ensure reinforcing steel is Grade 60 with 3" of
conduits entering the service from underground.
5.Furnish and install rigid metallic ells in all steel pole and steel frame foundations for all
listed mechanical connectors rated for embedment in concrete. See Inset B.
4.Bond one of the anchor bolts to the rebar cage with 6 AWG bare stranded copper conductor. Use
and install leveling nuts for all anchor bolts.
3 ‚ in. to 3 • in. of the exposed anchor bolt projecting above finished foundation. Provide
anchor bolts for overhead service supports. Ensure anchor bolts have 3 in of thread, with
bolts for underground service supports. Provide and install galvanized Æ’ in. x 56 in. x 4 in.
3.Provide and install galvanized Æ’ in. x 18 in. x 4 in. (dia. x length x hook length) anchor
service drop to the pole in conformance with the electric utility provider's specifications.
2.Provide poles for overhead service with an eyebolt or similar fitting for attachment of the
with zinc-rich paint before installing.
members as approved. Do not stack channel. File smooth and paint field cut ends of all channel
deep Unistrut, Kindorf, B-line or equal. Bolt or weld all channel and hardware to vertical
steel or stainless steel channel strut, 1 • in. or 1 †in. wide by 1 in. up to 3 ƒ in.
(DMS)11080 "Electrical Services." Mount all equipment and conduit on 12 gauge galvanized
1.Provide steel pole and steel frame supports as per TxDOT Departmental Material Specification
before installing.
check with utility
than the 20" shown,
support to be taller
electrical service
may require the
grade. Circumtances
20' measured from
equal.)
B-line or
Unistrut,
(Kindorf,
the Engineer.
approved by
other arrangement
bracket or
Channel
weatherhead.
to be below
of service drop
attachment
Point of
utility.
called for by the
unless otherwise
and 5' in between
from the ends,
spacing, 3'max
Conduit support
NOTE:
•"•"
Steel post
3/4" dia.
of pole.
below the top
4" typical
to be 2" to 6",
weatherhead
Top of
3'-6"SERVICE SUPPORT TY SF (O) & SF (U)60" (typ.)Enclosure
Service
required)
(when
switch
Safety
2"
PVC
TopThreadAnchor Bolt Length BASE PLATE DETAIL
8"
5 •"
1 ‚"
drill shaft
24" Diameter
8"5 •"
1 ‚"
Conduit
BOTTOM OF POLE
Å "
‰"
Æ’"
‚"
CL
smooth
be ground
edges shall
All rough
‰"‰"
METER
Varies
boss
Threaded
RMC
2"
PVCRMC
4" (typ.)
2" to 6"
DENTON18September 3, 2019\\HZDALLAS1\disk1\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.2 AutoCAD\TRAFFIC\Details115
DN:CK:DW:CK:FILE:
JOB
COUNTY
SECT
DIST
REVISIONS
TxDOT TxDOT TxDOT TxDOT
HIGHWAY
SHEET NO.
C TxDOT
CONT FILE:DATE:
Standard
Division
Operations
Traffic
ED(8)-14
ed8-14.dgn
SYSTEM DETAILS
TYPICAL TRAFFIC SIGNAL
ELECTRICAL DETAILS
Line
INSET A
of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:Entrance
Service
type
signal pole
sheets for
See layout
box
Ground
71H
TRAFFIC SIGNAL NOTES
18" max.
slack length, 12" min.,
weatherhead. Conductor
conductor exits the
with red tape where
conductor's insulation
of Line 1 or Line 2
color code 6" length
Red insulation or
exits weatherhead.
tape where conductor
insulation with white
neutral conductor's
color code 6" of
White insulation or
3 Wire
120/240 Volt
See Note 7
Meter
See Note 7
Enclosure
Service
Inset A
See Note 11
and conduit details
sheet for foundation
See TS-FD standard
for details)
layout sheet
Conduits (See
SIGNAL CONTROLLER SIGNAL POLE
See Note 6
electrode conductor
service grounding
connect electrical
tank ground fitting,
•" X 13 UNC. Install
Drill, top and thread
October 2014
FRONT VIEW
SIGNAL POLE WITH SERVICE
additional details.
and electrical service data chart for
See electrical details, layout sheets,
on signal pole shown as an example.
Type T electrical service mounted
End Fitting
or Bell
Bushing
(see side view)
Ground box
SIGNAL CONTROLLER
SIDE VIEW
conduits that are required.
locations and any additional
sheets for ground box
requirements. See layout
conduit and grounding
See TS-CF standard for
view)
requirements (see side
conduits, and grounding
number of required
foundation details,
for controller
See TS-CF standard
minimum burial depth for conduit placed under a roadway is 24".
11. For all conduits, ensure the burial depth is a minimum of 18". Ensure the
seal conduit ends.
entering enclosures with duct seal or expanding foam. Do not use silicone to
grounding bushing to the ground bus with a bonding jumper. Seal all conduits
conduits not connected to conduit-sealing hub or threaded boss. Bond the
or threaded boss such as meter hub. Install a grounding bushing on all metal
10. Terminate conduits entering the top of enclosures with a conduit-sealing hub
to the signal installation.
9. Lock all enclosures and bolt down all ground box covers before applying power
on traffic signal cables after termination.
To prevent electronics damage, do not conduct insulation resistance tests
power conductors as required in Item 620 "Electrical Conductors" and ED(3).
8. Conduct pull tests and insulation resistance tests on all illumination and
signal pole for attaching conduit.
in the enclosure. Band or drill and tap properly sized stand-off straps to
each enclosure. Install properly sized stainless steel washers on each bolt
to bands using two-bolt brackets. Install brackets near top and bottom of
steel bands. Ensure bands are a minimum width of Æ’ in. Secure enclosures
7. Mount electrical service enclosure and meter to signal pole with stainless
entrance conduit and branch circuit conduit as shown in the plans.
ground fitting. See Inset A detail for further information. Size service
is as short and straight as possible from the enclosure to the tank
ground fitting. Ensure electrical service grounding electrode conductor
Connect the electrical service grounding electrode conductor to the tank
bottom of the enclosure for the service grounding electrode conductor.
electrical service enclosure. Provide properly sized hole through the
Provide and install tank ground fitting 4 in. to 6 in. directly below
6. Drill and tap signal poles for • in. X 13 UNC tank ground fitting.
details.
rated for embedment in concrete. See TXDOT standard TS-FD for further
6 AWG stranded copper conductors. Use listed mechanical connectors
5. Bond anchor bolts to rebar cage in two locations using #3 bars or
ground the fixture to the pole with a 12 AWG green XHHW conductor.
4. If internally illuminated street name signs are approved for use,
associated traffic signal system test.
installed roadway luminaires for proper operation as a part of the
Assemblies," except for performance testing of luminaires. Test
material and construction sections of Item 610, "Roadway Illumination
3. Provide roadway luminaires, when required, in accordance with the
conductor.
the electrical system. Bond all exposed metal parts to the grounding
2. Include an equipment grounding conductor in all conduits throughout
1. Do not pass luminaire conductors through the signal controller cabinet.
DENTON18September 3, 2019\\HZDALLAS1\disk1\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.2 AutoCAD\TRAFFIC\Details116
DN:CK:DW:CK:FILE:
JOB
COUNTY
SECT
DIST
REVISIONS
TxDOT TxDOT TxDOT TxDOT
HIGHWAY
SHEET NO.
C TxDOT
of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:CONT FILE:DATE:Standard
Division
Operations
Traffic
ED(9)-14
ed9-14.dgn
PEDESTAL SERVICE TYPE PS
ELECTRICAL SERVICE SUPPORT
ELECTRICAL DETAILS
6"6"16"
min.min.
LINE
LOAD 14"6"
min.
6"
min.
Leveling Washers2"LOAD
1
10
7
8
6
9
3
5
4
Studs (as required)
Equipment Mounting
11 12
13
Studs (as required)
Equipment Mounting
12"Reinforcing Steel
17 ‚"2
5
LOAD SIDE CONDUIT
LOAD SIDE CONDUIT
LOAD SIDE CONDUIT
16"
2
SECTION A-A ANCHOR BOLT DETAIL
FRONT VIEW
SIDE VIEW
LINE SIDE CONDUIT
Hex Nut
Lock Washer
Flat Washer
20"1
2
3
4
5
6
7
8
9
10
11
12
13
LEGEND
Meter Socket, (when required)
Meter Socket Window, (when required)
Equipment Mounting Panel
Photo Electric Control Window, (When required)
Hinged Deadfront Trim
Load Side Conduit Trim
Line Side Conduit Area
Utility Access Door, with handle
Pedestal Door
Hinged Meter Access
Control Station (H-O-A Switch)
Branch Circuit Breakers
Main Disconnect
71J
PEDESTAL SERVICE NOTES
5"14
Steel
Reinforcing
14 Copper Clad Ground Rod - 5/8" X 10'48" min.max. 3"18" min.14
14
AA
bolt detial
See anchor
Bushings
or Grounding
Bell End Fittings
plan details
determined by
of conduits
Size and number
panel. CB Handles shall protrude through hinged deadfront trim.
individual circuit breakers (CB) mounted on an equipment mounting
TYPE C shown, TYPE A similar except that TYPE A shall have
October 2014
17" min.
properly terminated.
extension conduits are metal, grounding bushings must be installed with a bonding jumper
rigid metal conduits are more than 2 in. below the top of the concrete foundation. Where
for underground conduit and feeders. PVC extensions may be installed provided the ends of the
8. Ensure all elbows in the foundation are sized as per utility provider's conduit requirements
7. Do not use liquidtight flexible metal conduit (LFMC) on pedestal type services.
rocking or movement of the service enclosure at no additional cost to the department.
the service enclosure is level front to back and side to side within ‚ in. Repair
rise in the foundation of „ in. per foot. When properly installed, ensure the top of
are used, ensure no more than „ in. gap at any corner. Do not exceed a maximum dip or
6. Finish top of concrete foundation in a neat and workmanlike manner. If leveling washers
bolt, a properly sized locknut and a flat washer.
the anchors in the foundation with a • in. galvanized or stainless steel machine thread
each corner of enclosure. Secure each of the four corners of the pedestal enclosure to
mounting pedestal enclosure to foundation. Anchor location to match mounting holes in
5. Install • in. X 2 ˆ in. minimum length concrete single expansion type anchors for
for Concrete."
4. Provide #4 reinforcing steel for foundations in accordance with Item 440, "Reinforcement
but is considered subsidiary to Item 628.
Item 420, "Concrete Substructures," except that concrete will not be paid for directly
3. Provide Class A or C concrete for pedestal service foundations in accordance with
complies with local utility requirements.
2. When a meter socket is required, provide a socket with a minimum 100 amp rating that
utility company prior to manufacturing the pedestal enclosure.
installing the electrical pedestal service. Submit any changes required by the
Contact the local utility company for approval of pedestal details prior to
hardware and installation details of services meet utility company specifications.
"Roadway Illumination and Electrical Supplies," Item 628. Ensure all mounting
listed on the Material Producers list (MPL) on the Department's web site under
(PS)" and Item 628 "Electrical Services. "Provide pedestal electrical services as
Specifications (DMS)11080 "Electrical Services", 11085 "Electrical Services-Pedestal
1. Manufacture pedestal electrical services in accordance with Departmental Material
DENTON18September 3, 2019\\HZDALLAS1\disk1\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.2 AutoCAD\TRAFFIC\Details117
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TSS01.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TSS01.dgn1:404:40:16 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
NOTES:
AND SIGNAGE PLAN
PAVEMENT MARKING
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
FOR ADDITIONAL INFORMATION.
2. SEE PAVING PLAN AND PROFILE SHEETS
(TMUTCD) 2011.
ON UNIFORM TRAFFIC CONTROL DEVICES
VERSION OF THE TEXAS MANUAL2
IN ACCORDANCE WITH THE 2011 REVISION
1. ALL SIGNING AND STRIPING SHALL BE
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
88+00 90+00
91+00
87+00
1
0
0
73+0
0
1
0
0
7
4
+0
0
89+00
PARKING AREA
PARKING AREA
S ONLYONLYONLYONLYONLYONLYONLYONLYMATCHLINE STA 91+50McKINNEY STREET N LOOP
2
88S LOOP
2
8
8
(TYP.)
10'
(TYP.)
15'
(TYP.)
15'
LANE ENDS
LEFT
MERGE
REMOVE EX. SIGN
CL McKINNEY STREET
CL LOOP 288
BAR(TYP.)
THERMOPLASTIC STOP
24" WHITE
WORD (TYP.)
THERMOPLASTIC
WHITE ARROW(TYP.)
WHITE THERMOPLASTIC
12.5'
(TYP.)
THERMOPLASTIC STRIPE
4" YELLOW
118
STRIPE(TYP.)
THERMOPLASTIC
4" WHITE
TO 11' AT STA 92+80
FROM 13' AT STA 91+50
BEGIN LANE TRANSITION
TO 11.5' AT STA 92+91
FROM 14' AT STA 90+65
BEGIN LANE TRANSITION 14'13'EX. SIGN ASSEMBLY
REMOVE AND RESET
LOOP
288
LOOP
288
NORTHSOUTH
12.5'(TYP.)
THERMOPLASTIC STRIPE
4" WHITE
(TYP.)
THERMOPLASTIC STRIPE
24" WHITE
(TYP.)
THERMOPLASTIC STRIPE
6" WHITE
(TYP.)
TRAFFIC BUTTON
TY II W-C/R
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TSS02.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TSS02.dgn1:404:40:18 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
NOTES:
AND SIGNAGE PLAN
PAVEMENT MARKING
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
FOR ADDITIONAL INFORMATION.
2. SEE PAVING PLAN AND PROFILE SHEETS
(TMUTCD) 2011.
ON UNIFORM TRAFFIC CONTROL DEVICES
VERSION OF THE TEXAS MANUAL2
IN ACCORDANCE WITH THE 2011 REVISION
1. ALL SIGNING AND STRIPING SHALL BE
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
V
E
PARKING AREA
S
PARKING AREA
92+00 93+00 94+00 95+00
96+00ONLYONLYONLYONLY
97+00 98+00 99+00 100+00 101+00
V
V
PARKING AREA
S
S SMATCHLINE STA 91+50McKINNEY STREET
MATCHLINE STA 96+50DRIVEDUCHESS McKINNEY STREET
MATCHLINE STA 96+50MATCHLINE STA 101+50REMOVE EX. SIGN
45
LIMIT
SPEED
(TYP.)
10'
(TYP.)
15'
(TYP.)
15'
(TYP.)
10'
(TYP.)
15'
(TYP.)
15'
STRIPE (TYP.)
THERMOPLASTIC
4" WHITE
CL McKINNEY STREET
STRIPE (TYP.)
THERMOPLASTIC
6" WHITE
EX. SIGN
REMOVE AND RESET
THERMOPLASTIC STRIPE
4" DOUBLE YELLOW
STRIPE (TYP.)
4" YELLOW THERMOPLASTIC
STRIPE (TYP.)
4" YELLOW THERMOPLASTIC
ARROW (TYP.)
THERMOPLASTIC
WHITE
STOP BAR(TYP.)
THERMOPLASTIC
24" WHITE
EX. BUS STOP SIGN
REMOVE AND REPLACE
EX. BUS STOP SIGN
REMOVE AND REPLACE
W3-3
EX. SIGN
REMOVE AND REPLACE
REMOVE AND REPLACE EX. SIGN
R1-1
35
LIMIT
SPEED
24x30
R2-1
WORD (TYP.)
THERMOPLASTIC
WHITE
STRIPE (TYP.)
THERMOPLASTIC
4" WHITE
STRIPE (TYP.)
THERMOPLASTIC
4" WHITE
(TYP.)
10'
(TYP.)
15'
(TYP.)
15'11'12'11'11.5'11.5'11.5'11'12'11'11.5'
STRIPE (TYP.)
THERMOPLASTIC
4" YELLOW
11911.5'TO 11.5' AT STA 92+91
FROM 14' AT STA 90+65
END LANE TRANSITION 11' TO 11' AT STA 92+80
FROM 13' AT STA 91+50
END LANE TRANSITION
(TYP.)
DOTTED STRIPE
THERMOPLASTIC
4" WHITE
THERMOPLASTIC ARROWS
WHITE
THERMOPLASTIC ARROWS
WHITE
(TYP.)
TRAFFIC BUTTON
TY II A-A
(TYP.)
TRAFFIC BUTTON
TY II A-A
STRIPE (TYP.)
THERMOPLASTIC
4" WHITE
(TYP.)
THERMOPLASTIC STRIPE
24" WHITE
PATHS (TYP.)
AVOID WHEEL
STRIPING TO
CROSSWALK
THERMOPLASTIC
24" WHITE
30x36
R3-5R
ONLY
STRIPE (TYP.)
THERMOPLASTIC
6" WHITE
(TYP.)
TRAFFIC BUTTON
TY II W-C/R
(TYP.)
TRAFFIC BUTTON
TY II W-C/R
(TYP.)
TRAFFIC BUTTON
TY II W-C/R
STREET
CL McKINNEY
36"X36"
W4-1aTRIGHT
MERGE
TRAFFIC
THRU
ONLY ONLY ONLY
R3-8B
48"X30"
(TYP.)
STRIPING
LANE DROP
THERMOPLASTIC
6" WHITE
(TYP.)
9'
(TYP.)
3'(TYP.)
TRAFFIC BUTTON
TY II W-C/R
12.5'(TYP.)
THERMOPLASTIC STRIPE
4" WHITE
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TSS03.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TSS03.dgn1:404:40:21 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
NOTES:
AND SIGNAGE PLAN
PAVEMENT MARKING
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
FOR ADDITIONAL INFORMATION.
2. SEE PAVING PLAN AND PROFILE SHEETS
(TMUTCD) 2011.
ON UNIFORM TRAFFIC CONTROL DEVICES
VERSION OF THE TEXAS MANUAL2
IN ACCORDANCE WITH THE 2011 REVISION
1. ALL SIGNING AND STRIPING SHALL BE
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
DBL. 10" HACKBERRY
18" ELM 6" TREE
TRI 4" TREE
QUAD 6" ELM
DBL. 8" HACKBERRY 6" ELM DBL. 6"/12" HACKBERRY DBL. 6" HACKBERRY DBL. 8" HACKBERRY
4" ELM
6" ELM
DBL. 12" HACKBERRY
DBL. 6" ELM
10" TREE
S
102+00 103+00 104+00 105+00
106+00
106+00
107+00 108+00 109+00 110+00
V
PARKING AREA PARKING AREA PARKING AREA
CONCRETE
PARKING AREA
PARKING AREA
PARKING AREA
24" HACKBERRYDBL. 12" TREE
24" TREETRI 6" TREE
15" HACKBERRY10" CEDAR
DBL. 10" TREE
DBL. 12" HACKBERRY
S
(TYP.)10'
(TYP.)15'
(TYP.)15'
STRIPE(TYP.)
THERMOPLASTIC
4" WHITE MATCHLINE STA 106+00MATCHLINE STA 101+50McKINNEY STREET
MATCHLINE STA 106+00MATCHLINE STA 110+50McKINNEY STREET
(TYP.)
10'
(TYP.)
15'
(TYP.)
15'
STRIPE(TYP.)
THERMOPLASTIC
4" WHITE
(TYP.)
10'
(TYP.)
15'
(TYP.)
15'
STRIPE(TYP.)
THERMOPLASTIC
4" WHITE
(TYP.)
10'
(TYP.)
15'
(TYP.)
15'
STRIPE (TYP.)4" YELLOW THERMOPLASTIC
STRIPE (TYP.)
4" YELLOW THERMOPLASTIC
EX. SIGN
REMOVE AND RESET
LOOP
288
JCT
EX. SIGN
REMOVE AND REPLACE
30x30
W3-3
STRIPE(TYP.)
THERMOPLASTIC
4" WHITE
REFERENCE ONLY11'11.5'12'11'11.5'11'11.5'12'11'11.5'DONE BY OTHERS TO STA 119+50
CONTRACT, BEGIN WORK TO BE
STA 106+00 END WORK THIS
120
THERMOPLASTIC ARROWS
WHITE
ARROWS
THERMOPLASTIC
WHITE
CL McKINNEY STREET
CL McKINNEY STREET
(TYP.)
TRAFFIC BUTTON
TY II A-A
(TYP.)
TRAFFIC BUTTON
TY II A-A
(TYP.)
TRAFFIC BUTTON
TY II W-C/R
(TYP.)
TRAFFIC BUTTON
TY II W-C/R
(TYP.)
TRAFFIC BUTTON
TY II W-C/R
(TYP.)
TRAFFIC BUTTON
TY II W-C/R
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TSS04.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TSS04.dgn1:404:40:23 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
NOTES:
AND SIGNAGE PLAN
PAVEMENT MARKING
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
FOR ADDITIONAL INFORMATION.
2. SEE PAVING PLAN AND PROFILE SHEETS
(TMUTCD) 2011.
ON UNIFORM TRAFFIC CONTROL DEVICES
VERSION OF THE TEXAS MANUAL2
IN ACCORDANCE WITH THE 2011 REVISION
1. ALL SIGNING AND STRIPING SHALL BE
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
CONCRETE
CONCRETE
E
E
PARKING AREA
S
S
S
D
D
S
S
PTZ
111+00 112+00 113+00 114+00 115+00
222+00223+00ONLY
ONLYONLY ONLY116+00 117+00 118+00 119+00
STRIPE(TYP.)
THERMOPLASTIC
4" WHITE
MATCHLINE STA 110+50McKINNEY STREET
MATCHLINE STA 115+50MATCHLINE STA 115+50ROADN MAYHI
LL ROADS MAYHI
LL
McKINNEY STREET
REMOVE EX. SIGN
45
LIMIT
SPEED
EX. BUS STOP SIGN
REMOVE AND REPLACE
(TYP.)
10'
(TYP.)
15'
(TYP.)
15'
(TYP.)
10'
(TYP.)
15'
(TYP.)
15'
CL McKINNEY STREET
CL McKINNEY STREET
REMAIN
PARKING SIGN TO
EX. HANDICAP
STRIPE(TYP.)
THERMOPLASTIC
6" WHITE
(TYP.)
10'
(TYP.)
15'
(TYP.)
15'
STOP BAR(TYP.)
THERMOPLASTIC
24" WHITE
ROAD STRIPING
MATCH EX. MAYHILL
(20' SPACING TYP.)
STRIPING
THERMOPLASTIC
24" WHITE
STRIPE(TYP.)
THERMOPLASTIC
4" WHITE
MATCHLINE STA 119+00
STRIPE (TYP.)
4" YELLOW THERMOPLASTIC
STRIPE (TYP.)
4" YELLOW THERMOPLASTIC
35
LIMIT
SPEED
24X30
R2-1
YIELD
EX. SIGN TO REMAIN
ONLY
RIGHT LANE
EX. SIGN TO REMAIN
WORD(TYP.)
WHITE THERMOPLASTIC
ARROW(TYP.)
WHITE THERMOPLASTIC
STRIPE(TYP.)
THERMOPLASTIC
4" WHITE
(TYP.)
10'
(TYP.)
15'
(TYP.)
15'
STRIPE(TYP.)
THERMOPLASTIC
4" WHITE
STRIPE (TYP.)
4" YELLOW THERMOPLASTIC
REFERENCE ONLY
REFERENCE ONLY11.5'11'12'11'11.5'11.5'11.5'11'11'12'121
MATCH EX. MAYHILL ROAD STRIPING
(20' SPACING TYP.)
24" WHITE THERMOPLASTIC STRIPING
STRIPE(TYP.)
THERMOPLASTIC
6" WHITE
ARROW(TYP.)
WHITE THERMOPLASTIC
WORD(TYP.)
THERMOPLASTIC
WHITE
ARROWS
THERMOPLASTIC
WHITE
(TYP.)
TRAFFIC BUTTON
TY II A-A
(TYP.)
TRAFFIC BUTTON
TY II A-A
(TYP.)
TRAFFIC BUTTON
TY II A-A
PATHS(TYP.)
AVOID WHEEL
STRIPING TO
CROSSWALK
THERMOPLASTIC
24" WHITE
(TYP.)
TRAFFIC BUTTON
TY II W-C/R
(TYP.)
TRAFFIC BUTTON
TY II W-C/R
(TYP.)
TRAFFIC BUTTON
TY II W-C/R
(TYP.)
TRAFFIC BUTTON
TY II W-C/R
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TSS05.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TSS05.dgn1:404:40:26 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
AND SIGNAGE PLAN
PAVEMENT MARKING
NOTES:
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
FOR ADDITIONAL INFORMATION.
2. SEE PAVING PLAN AND PROFILE SHEETS
(TMUTCD) 2011.
ON UNIFORM TRAFFIC CONTROL DEVICES
VERSION OF THE TEXAS MANUAL2
IN ACCORDANCE WITH THE 2011 REVISION
1. ALL SIGNING AND STRIPING SHALL BE
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
BAYLOR UNIVERSITY
4515 E McKINNEY STREET
KENNETH L & GLADYS F STOUT
4663 E McKINNEY STREET
MEMORIAL BAPTIST CHURCH OF DENTON
LOT 151 (PT)
LOT 161 LOT 162, 163, 164 (OLD DCAD 1P, 1P2, 1R), AC
119+00 120+00 121+00
PARKING AREA
PBX
PARKING AREA
PBX
8" HACKBERRY
DBL. 15"/24" PECAN24" PECAN
27" PECANDBL. 18" ELM
15" PECAN
TRI 12" PECAN
30" PECAN
DBL. 8" TREEDBL. 8"/15" TREE
S
BAYLOR UNIVERSITY
4673 E McKINNEY STREET
MEMORIAL BAPTIST CHURCH OF DENTON
BCI REAL ESTATE VENTURES,LP
LOT 151 (PT)
LOT 166
LOT 151 (PT)
4683 E McKINNEY STREET
SAYR RESOURCES INC
LOT 167
4663 E McKINNEY STREET
MEMORIAL BAPTIST CHURCH OF DENTON
LOT 162, 163, 164 (OLD DCAD 1P, 1P2, 1R), AC
122+00 123+00 124+00 125+00 126+00
CL McKINNEY STREET
STRIPE (TYP.)
THERMOPLASTIC
4" WHITEMATCHLINE STA 119+00MATCHLINE STA 121+50MATCHLINE STA 121+50MATCHLINE STA 126+00CL McKINNEY STREET
EX. SIGN
REMOVE
EX. SIGN
REMOVE
STRIPE(TYP.)
THERMOPLASTIC
4" WHITE
(TYP.)
10'
(TYP.)
15'
(TYP.)
15'
STRIPE(TYP.)
THERMOPLASTIC
4" WHITE
STRIPE (TYP.)
4" YELLOW THERMOPLASTIC
(TYP.)
10'
(TYP.)
15'
(TYP.)
15'
(TYP.)
10'
(TYP.)
15'
(TYP.)
15'
STRIPE(TYP.)
THERMOPLASTIC
4" WHITE
(TYP.)
10'
(TYP.)
15'
(TYP.)
15'
McKINNEY STREET
McKINNEY STREET STRIPE (TYP.)
4" YELLOW THERMOPLASTIC 11'11.5'12'11'11.5'11'11.5'12'11'11.5'END WORK TO BE DONE BY OTHERS
BEGIN WORK THIS CONTRACT
STA 119+50
122
ARROWS
WHITE THERMOPLASTIC
ARROWS
WHITE THERMOPLASTIC
(TYP.)
TRAFFIC BUTTON
TY II A-A
(TYP.)
TRAFFIC BUTTON
TY II A-A
AHEAD
EX. SIGN ASSEMLY
REMOVE AND REPLACE
(TYP.)
TRAFFIC BUTTON
TY II W-C/R
(TYP.)
TRAFFIC BUTTON
TY II W-C/R
(TYP.)
TRAFFIC BUTTON
TY II W-C/R
(TYP.)
TRAFFIC BUTTON
TY II W-C/R
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TSS06.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TSS06.dgn1:404:40:28 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
AND SIGNAGE PLAN
PAVEMENT MARKING
NOTES:
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
FOR ADDITIONAL INFORMATION.
2. SEE PAVING PLAN AND PROFILE SHEETS
(TMUTCD) 2011.
ON UNIFORM TRAFFIC CONTROL DEVICES
VERSION OF THE TEXAS MANUAL2
IN ACCORDANCE WITH THE 2011 REVISION
1. ALL SIGNING AND STRIPING SHALL BE
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PBX
36" TREE
36" PECAN
2" TREE
36" PECAN
2" TREE
48" PECAN
DBL. 4"/15" HACKBERRY
6" HACKBERRY
21" CEDARDBL. 15"/24" PECAN
S
586.97
5/8" IRS W/RANDOM
35
ONLYBCI REAL ESTATE VENTURES,LP
5001 E McKINNEY STREET
BARBARA McDONALD COBB
LOT 151 (PT)
LOT 168
5043 E McKINNEY STREET
CHELA DARLINE McDONALD
LOT 169
126+00 127+00 128+00 129+00 130+00
BCI REAL ESTATE VENTURES,LP
5101 E McKINNEY STREET
DENTON ISD
5090 E McKINNEY STREET
EDIBERTO A RODRIGUEZ E McKINNEY STREET
KIM Y PHAM
LOT 151 (PT)
LOT 1R4
LOT 150 LOT 1
130+00 131+00 132+00 133+00 134+00
135+00
CONCRETE
PBX
E
ONLYONLYONLYONLYONLYMATCHLINE STA 130+00MATCHLINE STA 130+00MATCHLINE STA 135+00MATCHLINE STA 126+00McKINNEY STREET
McKINNEY STREETN CARPENTER ROADRYAN WAY
REMOVE EX. SIGN
45
LIMIT
SPEED
ARROW(TYP.)
THERMOPLASTIC
WHITE (TYP.)
15'
(TYP.)
10'
(TYP.)
15'
(TYP.)
15'
(TYP.)
10'
(TYP.)
15'
CL McKINNEY STREET
CL McKINNEY STREET
STOP BAR(TYP.)
THERMOPLASTIC
24" WHITE
EX. BUS STOP SIGN
REMOVE AND REPLACE
R1-1
EX. SIGN ASSEMBLY
REMOVE AND REPLACE
EX. BUS STOP SIGN
REMOVE AND REPLACE
STRIPE (TYP.)
THERMOPLASTIC
4" WHITE
ASSEMBLY
ZONE SIGN
EX.SCHOOL
RESET
REMOVE AND
(TYP)
15'
(TYP)
10'
(TYP)
15'
STRIPE(TYP.)
THERMOPLASTIC
6" WHITE
SOLID STRIPE
THERMOPLASTIC
12" WHITE
EX. SIGN
REMOVE AND RESET
STRIPE (TYP.)
4" YELLOW THERMOPLASTIC
STRIPE (TYP.)
THERMOPLASTIC
4" WHITE
WORD(TYP.)
WHITE THERMOPLASTIC
STRIPE (TYP.)
4" YELLOW THERMOPLASTIC
STRIPE (TYP.)
THERMOPLASTIC
4" WHITE11.5'11'12'11'11.5'11.5'11'12'11'11.5'127
PAVEMENT MARKINGS AND SIGNAGE
RYAN WAY
SEE SH. FOR
123
ARROWS
WHITE THERMOPLASTIC
ARROW(TYP.)
THERMOPLASTIC
WHITE
STOP BAR
THERMOPLASTIC
24" WHITE
STRIPE(TYP.)
THERMOPLASTIC
6" WHITE
ARROWS
WHITE THERMOPLASTIC
(TYP.)
15'
(TYP.)
10'
(TYP.)
15'
STRIPE (TYP.)
THERMOPLASTIC
4" WHITE
(TYP.)
TRAFFIC BUTTON
TY II A-A
TRAFFIC BUTTON (TYP.)
TY II A-A
EX. SIGN ASSEMLY
REMOVE AND REPLACE
30X30
S1-1
24X12
SW16-7P(L)
REMOVE EX. SIGN ASSEMBLY
35
LIMIT
SPEED
ZONE
END SCHOOL
24x10
S5-2aTP
24x30
R2-1
PATHS(TYP.)
AVOID WHEEL
STRIPING TO
CROSSWALK
THERMOPLASTIC
24" WHITE
STRIPE
THERMOPLASTIC
4" YELLOW
(TYP.)
TRAFFIC BUTTON
TY II W-C/R
(TYP.)
TRAFFIC BUTTON
TY II W-C/R
(TYP.)
TRAFFIC BUTTON
TY II W-C/R
(TYP.)
TRAFFIC BUTTON
TY II W-C/R
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TSS07.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TSS07.dgn1:404:40:31 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
AND SIGNAGE PLAN
PAVEMENT MARKING
NOTES:
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
FOR ADDITIONAL INFORMATION.
2. SEE PAVING PLAN AND PROFILE SHEETS
(TMUTCD) 2011.
ON UNIFORM TRAFFIC CONTROL DEVICES
VERSION OF THE TEXAS MANUAL2
IN ACCORDANCE WITH THE 2011 REVISION
1. ALL SIGNING AND STRIPING SHALL BE
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
5101 E McKINNEY STREET
DENTON ISD
E McKINNEY STREET
KIM Y PHAM
LOT 1R4
LOT 1
135+00 136+00 137+00 138+00
139+00
5101 E McKINNEY STREET
DENTON ISD
E McKINNEY STREET
KIM Y PHAM
E McKINNEY STREET
KIM Y PHAM
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
LOT 1R4 LOT 1
LOT 1, BLOCK A LOT 1, BLOCK B
139+00 140+00 141+00 142+00 143+00
V
E
ES
MATCHLINE STA 143+50MATCHLINE STA 139+00MATCHLINE STA 135+00MATCHLINE STA 139+00McKINNEY STREET
McKINNEY STREET
WAYGLENNGARY
STRIPE (TYP.)
THERMOPLASTIC
4" WHITE
(TYP.)
10'
(TYP.)
15'
(TYP.)
15'
REMOVE AND REPLACE EX. SIGN ASSEMBLY
R1-1
REMOVE EX. SIGN
45
LIMIT
SPEED
STRIPE (TYP.)
THERMOPLASTIC
4" WHITE
(TYP.)
10'
(TYP.)
15'
(TYP.)
15'
(TYP)
10'
(TYP)
15'
(TYP)
15'
STRIPE(TYP.)
THERMOPLASTIC
6" WHITE
EX. SIGN ASSEMBLY
REMOVE AND REPLACE
R1-1
STRIPE(TYP.)
THERMOPLASTIC
6" WHITE
TO REMAIN
EX. SIGN
SOLID STRIPE
THERMOPLASTIC
12" WHITE
STRIPE (TYP.)
THERMOPLASTIC
4" WHITE
EX. BUS STOP SIGN
REMOVE AND RESET
RESET EX. SIGN
REMOVE AND
SIGN
BUS STOP
RESET EX.
REMOVE AND
STRIPE (TYP.)
THERMOPLASTIC
4" YELLOW
(TYP.)
10'
(TYP.)
15'
(TYP.)
15'
ZONE
END SCHOOL
24x10
S5-2aTP
35
LIMIT
SPEED
24x30
R2-1
ASSEMBLY
ZONE SIGN
EX.SCHOOL
RESET
REMOVE AND
STRIPE (TYP.)
THERMOPLASTIC
4" WHITE
STRIPE (TYP.)
4" YELLOW THERMOPLASTIC
STRIPE (TYP.)
4" YELLOW THERMOPLASTIC
STOP BAR
THERMOPLASTIC
24" WHITE
STOP BAR
THERMOPLASTIC
24" WHITE 11.5'11'12'11'11.5'11.5'11'12'11'11.5'124
ARROWS
WHITE THERMOPLASTIC
ARROWS
WHITE THERMOPLASTIC
ARROWSWHITE THERMOPLASTIC
(TYP.)
TRAFFIC BUTTON
TY II A-A
(TYP.)
TRAFFIC BUTTON
TY II A-A
WHEEL PATHS (TYP.)
CROSSWALK STRIPING TO AVOID
24" WHITE THERMOPLASTIC
AVOID WHEEL PATHS (TYP.)
CROSSWALK STRIPING TO
24" WHITE THERMOPLASTIC
(TYP.)
TRAFFIC BUTTON
TY II W-C/R
(TYP.)
TRAFFIC BUTTON
TY II W-C/R
(TYP.)
TRAFFIC BUTTON
TY II W-C/R
(TYP.)
TRAFFIC BUTTON
TY II W-C/R
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TSS08.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TSS08.dgn1:404:40:33 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
AND SIGNAGE PLAN
PAVEMENT MARKING
NOTES:
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
FOR ADDITIONAL INFORMATION.
2. SEE PAVING PLAN AND PROFILE SHEETS
(TMUTCD) 2011.
ON UNIFORM TRAFFIC CONTROL DEVICES
VERSION OF THE TEXAS MANUAL2
IN ACCORDANCE WITH THE 2011 REVISION
1. ALL SIGNING AND STRIPING SHALL BE
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
S
E McKINNEY STREET
KIM Y PHAM
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
E McKINNEY STREET
ATMOS ENERGY CORP
LOT 1
LOT 147B
LOT 1, BLOCK B
144+00 145+00 146+00 147+00 148+00
E McKINNEY STREET
ATMOS ENERGY CORP
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
LOT 147B
LOT 1 LOT 1
148+00 149+00 150+00 151+00 152+00
CONCRETE E
S S
S
582.48
X CUT SET
38MATCHLINE STA 143+50MATCHLINE STA 148+00MATCHLINE STA 152+50MATCHLINE STA 148+00McKINNEY STREET
McKINNEY STREETS FORK DRIVE STRIPE (TYP.)
THERMOPLASTIC
4" WHITE
(TYP.)
10'
(TYP.)
15'
(TYP.)
15'
STRIPE (TYP.)
THERMOPLASTIC
4" WHITE
(TYP.)
15'
(TYP.)
10'
(TYP.)
15'
CL McKINNEY STREET
CL McKINNEY STREET
45
LIMIT
SPEED
REMOVE EX. SIGN
STRIPE (TYP.)
THERMOPLASTIC
4" WHITE
EX. BUS STOP SIGN
REMOVE AND RESET
(TYP.)
10'
(TYP.)
15'
(TYP.)
15'
STRIPE (TYP.)
4" YELLOW THERMOPLASTIC
24x30
R2-1
35
LIMIT
SPEED
STRIPE (TYP.)
4" YELLOW THERMOPLASTIC
(TYP.)
15'
(TYP.)
10'
(TYP.)
15'
STRIPE (TYP.)
THERMOPLASTIC
4" WHITE
STRIPE(TYP.)
THERMOPLASTIC
6" WHITE
STOP BAR
THERMOPLASTIC
24" WHITE 11.5'11'12'11'11.5'11.5'11'12'11'11.5'125
ARROWSWHITE THERMOPLASTIC
ARROWS
WHITE THERMOPLASTIC
ARROWS
WHITE THERMOPLASTIC
(TYP.)
TRAFFIC BUTTON
TY II A-A
(TYP.)
TRAFFIC BUTTON
TY II A-A
EX. BUS STOP SIGN
REMOVE AND RESET
LOT 147B
E McKINNEY STREET
ATMOS ENERGY CORP
35
LIMIT
SPEED
REMOVE EX. SIGN
EX. SIGN TO REMAIN
AHEAD
EX. SIGN ASSEMLY
REMOVE AND REPLACE
PATHS (TYP.)
TO AVOID WHEEL
CROSSWALK STRIPING
THERMOPLASTIC
24" WHITE
(TYP.)
TRAFFIC BUTTON
TY II W-C/R
(TYP.)
TRAFFIC BUTTON
TY II W-C/R
(TYP.)
TRAFFIC BUTTON
TY II W-C/R
(TYP.)
TRAFFIC BUTTON
TY II W-C/R
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TSS09.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TSS09.dgn1:404:40:35 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
AND SIGNAGE PLAN
PAVEMENT MARKING
NOTES:
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
FOR ADDITIONAL INFORMATION.
2. SEE PAVING PLAN AND PROFILE SHEETS
(TMUTCD) 2011.
ON UNIFORM TRAFFIC CONTROL DEVICES
VERSION OF THE TEXAS MANUAL2
IN ACCORDANCE WITH THE 2011 REVISION
1. ALL SIGNING AND STRIPING SHALL BE
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
S
E McKINNEY STREET
ATMOS ENERGY CORP
E McKINNEY STREET
ATMOS ENERGY CORP
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
LOT 147A
LOT 147B
LOT 1
153+00
154+00 155+00 156+00
157+00
E McKINNEY STREET
ATMOS ENERGY CORP
E McKINNEY STREET & TRINITY ROAD
THE WOODLANDS ON McKINNEY STREET LLC
K
O
R
N
U
P
A
U
L
& WE
N TS
AI
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
LOT 147A
LOT 143, 144L
O
T 108
LOT 1
157+00 158+00 159+00 160+00 161+00
585.97PK NAIL SET39
DDMATCHLINE STA 152+50MATCHLINE STA 157+00MATCHLINE STA 157+00McKINNEY STREET
McKINNEY STREET
STRIPE (TYP.)
THERMOPLASTIC
4" WHITE
MATCH EX. STRIPING
MATCH EX. STRIPING
PAINTED ARROW
REMOVE EX.
PAINTED ARROW
REMOVE EX.
PAINTED STRIPE
REMOVE EX.
STRIPE (TYP.)
THERMOPLASTIC
4" WHITE
PAINTED STRIPE
REMOVE EX. REMAIN (TYP.)
MARKINGS TO
EX. PAVEMENT11.7'11.7'12.5'11'13'11'12.5'
126
(TYP.)
TRAFFIC BUTTON
TY II A-A
REMOVE EX. SIGN
EX. SIGN
REMOVE AND REPLACE
35
LIMIT
SPEED
R2-1
REMOVE EX. SIGN
KEEP
RIGHT
AHEAD
REMOVE EX. SIGN ASSEMBLY
LANE ENDS
LEFT
MERGE
REMOVE EX. SIGN
AT STA 163+40
REMOVE EX. SIGN ASSEMBLY
500 FT
LANE ENDS
LEFT
MERGE
240'
(TYP.)
TRAFFIC BUTTON
TY II W-C/R
(TYP.)
TRAFFIC BUTTON
TY II W-C/R
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TSS10.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-TSS10.dgn1:404:40:38 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
AND SIGNAGE PLAN
PAVEMENT MARKING
NOTES:
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
FOR ADDITIONAL INFORMATION.
2. SEE PAVING PLAN AND PROFILE SHEETS
(TMUTCD) 2011.
ON UNIFORM TRAFFIC CONTROL DEVICES
VERSION OF THE TEXAS MANUAL2
IN ACCORDANCE WITH THE 2011 REVISION
1. ALL SIGNING AND STRIPING SHALL BE
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PBX
E
3
6
"
T
R
E
EBCI REAL ESTATE VENTURES,LP
5090 E McKINNEY STREET
EDIBERTO A RODRIGUEZ
5101 E McKINNEY STREET
DENTON ISD
LOT 169
LOT 151 (PT)
LOT 150
LOT 1R4
5043 E McKINNEY STREET
CHELA DARLINE McDONALD
CAB. H, PG. 62
20' UTILITY EASEMENT
PC 129+61.61
130+00131+00132+00ONLYONLYONLYONLYMcKINNEY STREETRYAN WAY
CL McKINNEY STREET1
0.
5'
1
0'
1
0.
5'
127
ONLY ONLY ONLY
R3-8SP
48X30
CROSSWALK STRIPING(TYP.)
24" WHITE THERMOPLASTIC
STRIPE(TYP.)
THERMOPLASTIC
6" WHITE
ARROW(TYP.)
THERMOPLASTIC
WHITE
STOP BAR
THERMOPLASTIC
24" WHITE
EX. SIGN
REMOVE AND RESET
EX. SIGN
REMOVE AND RESET
EX. SIGN
REMOVE AND RESET
WORD(TYP.)
THERMOPLASTIC
WHITE
24X12
SW16-7P(L)
30X30
S1-1
(TYP.)
THERMOPLASTIC STRIPE
4" WHITE
123
PAVEMENT MARKINGS AND SIGNAGE
McKINNEY STREET
SEE SH. FOR
TSR(3)-13
7-13
tsr3-13.dgn
128
http://www.txdot.gov/
can be found at the following website.
The Standard Highway Sign Designs for Texas (SHSD)
Square Feet
0.080 Less than 7.5
Greater than 15 0.125
0.100 7.5 to 15
Minimum Thickness
ALUMINUM SIGN BLANKS THICKNESS
USAGE COLOR SIGN FACE MATERIAL
WHITELEGEND & BORDERS
SHEETING REQUIREMENTS
BACKGROUND
TYPE A SHEETING
LEGEND & BORDERS BLACK ACRYLIC NON-REFLECTIVE FILM
ALL OTHERS
BACKGROUND TYPE A SHEETINGWHITE
TYPE B OR C SHEETING
DEPARTMENTAL MATERIAL SPECIFICATIONS
ALUMINUM SIGN BLANKS DMS-7110
SIGN FACE MATERIALS DMS-8300
USAGE COLOR SIGN FACE MATERIAL
WHITELEGEND & BORDERS
SHEETING REQUIREMENTS
TYPE D SHEETING
BACKGROUND TYPE B OR C SHEETING
& BORDERS
LEGEND, SYMBOLS
ALL
ALL OTHERS TYPE B OR C SHEETING
D AND I SERIES GUIDE SIGNS
REQUIREMENTS FOR BLUE, BROWN & GREEN
F CV-6W
Emod CV-5WR
E CV-4W
D CV-3W
C CV-2W
B CV-1W
TYPE B or C SHEETINGLEGEND & BORDERS
ALL OTHERS
GENERAL NOTES
ROUTE SIGNS
REQUIREMENTS FOR INDEPENDENT MOUNTED
Plan Sheets.
8. Mounting details of roadside signs are shown in the "SMD series" Standard
Specification requirements of DMS-7110 or approved alternative.
7. Sign substrate shall be any material that meets the Departmental Material
widths. The sign area outside the corner radius should be trimmed or rounded.
1 inch. Borders and corner radii within a parent sign must be of matching
much as 1/2 inch. Corner radii above 3 inches may vary in width as much as
and corner radii on parent sign are nominal. Borders may vary in width as
Highway Sign Designs for Texas". Dimensions shown and described for borders
6. Information regarding borders and radii for signs is found in the "Standard
colored background sheeting.
and borders on all other signs shall be cut-out white sheeting applied to
to colored background sheeting, or combination thereof. White legend, symbols
colored overlay film to white background sheeting or cut-out white sheeting
shall be applied by screening process with transparent color ink, transparent
5. Independent mounted route sign with white or colored legend and borders
a balanced appearance when spacing is not shown.
and any approved changes thereto. Lateral spacing of legend shall provide
4. Lateral spacing between letters and numerals shall conform with the SHSD,
or F).
Highway Administration (FHWA) Standard Highway Alphabets B, C, D, E, Emod
3. Route sign legend (ie. IH, US, SH and FM shields) shall use the Federal
plans.
(FHWA) Standard Highway Alphabets, when not specified in the SHSD, or in the
shall be used to replace the existing white Federal Highway Administration
2. White legend shall use the Clearview Alphabet. The following Clearview fonts
can be found in the "Standard Highway Sign Designs for Texas" (SHSD).
shown on sign tabulation sheet. Standard sign designs and arrow dimensions
1. Signs to be furnished shall be as detailed elsewhere in the plans and/or as
TYPICAL EXAMPLES
Standard
Division
Operations
Traffic
DN:CK:DW:CK:FILE:
JOB
COUNTY
SECT
DIST
REVISIONS
TxDOT TxDOT TxDOT TxDOT
HIGHWAY
SHEET NO.
C TxDOT
REQUIREMENTS
TYPICAL SIGN of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:CONT
FILE:DATE:October 2003
3
12-03
9-08
TYPICAL EXAMPLES
---
--
-$FILE$$DATE$$TIME$
---
--
-$FILE$$DATE$$TIME$C S J HWY
CTYDSTDOCUMENT NAMEDATE TIMETSR(4)-13
129
7-13
tsr4-13.dgn
GENERAL NOTES
Square Feet
0.080 Less than 7.5
Greater than 15 0.125
0.100 7.5 to 15
WRONG WAY SIGNS)
(STOP, YIELD, DO NOT ENTER AND
WRONG WAY SIGNS)
(EXCLUDING STOP, YIELD, DO NOT ENTER AND
REQUIREMENTS FOR WARNING SIGNS
FL
Minimum Thickness
BACKGROUND
USAGE COLOR SIGN FACE MATERIAL
RED
LEGEND & BORDERS
WHITE
BACKGROUND
USAGE COLOR SIGN FACE MATERIAL
TYPE A SHEETING
BLACK
WHITE
BACKGROUND
USAGE COLOR SIGN FACE MATERIAL
BLACK
WHITE
ACRYLIC NON-REFLECTIVE FILM
BACKGROUND TYPE B OR C SHEETING
http://www.txdot.gov/
can be found at the following website.
The Standard Highway Sign Designs for Texas (SHSD)
BACKGROUND
USAGE COLOR SIGN FACE MATERIAL
LEGEND & SYMBOLS
ACRYLIC NON-REFLECTIVE FILM
FL FL
FL
ALL OTHER
BLACK
TYPE B OR C SHEETING
REGULATORY SIGNS
REQUIREMENTS FOR WHITE BACKGROUND
REGULATORY SIGNS
REQUIREMENTS FOR RED BACKGROUND
ALL OTHER
BACKGROUND WHITE
TYPE B OR C SHEETING
LEGEND RED TYPE B OR C SHEETING
AND SYMBOLS
LEGEND,BORDERS
AND SYMBOLS
LEGEND,BORDERS
TYPE B OR C SHEETING
YELLOW
FLOURESCENT
LEGEND & BORDERS
AND SYMBOLS
LEGEND,BORDERS
YELLOW GREEN
FLOURESCENT
DEPARTMENTAL MATERIAL SPECIFICATIONS
ALUMINUM SIGN BLANKS THICKNESS
SHEETING REQUIREMENTS
SHEETING REQUIREMENTS
SHEETING REQUIREMENTS SHEETING REQUIREMENTS
ALUMINUM SIGN BLANKS DMS-7110
SIGN FACE MATERIALS DMS-8300
SPECIFIC SIGNS ONLY
REQUIREMENTS FOR FOUR
BACKGROUND ALL OTHERS
Standard Plan Sheets.
8. Mounting details for roadside mounted signs are shown in the "SMD series"
Specification requirements of DMS-7110 or approved alternative.
7. Sign substrate shall be any material that meets the Departmental Material
sheeting, or combination thereof.
ink, transparent colored overlay film or colored sheeting to background
6. Colored legend shall be applied by screening process with transparent colored
cut-out white sheeting to colored background sheeting, or combination thereof.
colored ink, transparent colored overlay film to white background sheeting or
5. White legend and borders shall be applied by screening process with transparent
thereof.
acrylic non-reflective black film to background sheeting, or combination
4. Black legend and borders shall be applied by screening process or cut-out
a balanced appearance when spacing is not shown.
and any approved changes thereto. Lateral spacing of legend shall provide
3. Lateral spacing between letters and numerals shall conform with the SHSD,
Standard Highway Alphabets (B, C, D, E, Emod or F).
2. Sign legend shall use the Federal Highway Administration (FHWA)
can be found in the "Standard Highway Sign Designs for Texas" (SHSD).
shown on sign tabulation sheet. Standard sign designs and arrow dimensions
1. Signs to be furnished shall be as detailed elsewhere in the plans and/or as
TYPE B OR C SHEETING
SYMBOLS RED TYPE B OR C SHEETING
TYPE B OR C SHEETING
TYPE B OR C SHEETING
ACRYLIC NON-REFLECTIVE FILM
TYPE A SHEETINGTYPE B OR C SHEETING
REQUIREMENTS
TYPICAL SIGN
Standard
Division
Operations
Traffic
DN:CK:DW:CK:FILE:
JOB
COUNTY
SECT
DIST
REVISIONS
TxDOT TxDOT TxDOT TxDOT
HIGHWAY
SHEET NO.
C TxDOT
of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:CONT
FILE:DATE:October 2003
4
REQUIREMENTS FOR SCHOOL SIGNS
TYPICAL EXAMPLES
12-03
9-08
TYPICAL EXAMPLES
TYPICAL EXAMPLES
---
--
-$FILE$$DATE$$TIME$Standard
Division
Operations
Traffic
TSR(5)-13
130
tsr5-13.dgn
7-13
(FOR MOUNTING TO GUIDE SIGN FACE)
TO BE TYPE A ALUMINUM SIGNS
SIGN BLANK PUNCHING DETAILS FOR ATTACHMENTS WHEN SPECIFIED
Holes
‰" dia.
USED ON SIGN NO.
Texas" manual.
"Standard Highway Sign Designs for
Arrow dimensions are shown in the
http://www.txdot.gov/
can be found at the following website.
The Standard Highway Sign Designs for Texas (SHSD)
NOTE:
NOTE:
NOTE
sheeting
background
Guide sign
sheeting
sign
Attachment
joints
at panel
must be cut
sheeting
Attachment
or "Fiberglass Signs".
2. Direct applied attachment signs will be subsidiary to "Aluminum Signs"
1. Sheeting for legend, symbols, and borders must be cut at panel joints.
screw
Sheet metal
Washer
Type A sign
aluminum
0.063"Type A sign
aluminum
0.063"
Washer
and bolt
1/4" nut
Lock washer
for Destination Signs (Type D)
9"12"
5.563"6.437"
2.75"
.563"R
3"
.438"
LETTER SIZETYPE USE
Exits
Lane
Single
Exits
Lane
Multiple
Type A Type B
DN:CK:DW:CK:FILE:
JOB
COUNTY
SECT
DIST
REVISIONS
TxDOT TxDOT TxDOT TxDOT
HIGHWAY
SHEET NO.
C TxDOT
of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:CONT
FILE:DATE:October 2003
5
SCREW ATTACHMENT
INTERSTATE ROUTE MARKERS U.S. ROUTE MARKERS STATE ROUTE MARKERS
‰" Holes
‰" Holes
‰" Holes
E
C
D
A
6"6"
6"
7•"
"Y" NO. OF EQUAL SPACES
2"
A
36
48
21
28
C D E
15
20
1•
1Æ’
Sign Size
24x24
30x24
36x36
45x36
48x48
60x48
"Y"
2
3
3
4
4
5
4
4
4
3
3
3
4
5
W X
24
24
36
36
48
48
4
5
6
3
Digits
No. of
R=3"
"X" NO. OF EQUAL SPACES
SPACES
3 EQUAL
2"
2"2"
W
4.5"4.5"
2.625"
.438"R
2.25"
.375"
ARROW DETAILS
6 inch letters.
to be used with
Standard arrow
8 inch letters.
to be used with
Standard arrow
24" max.6"
3"
EXIT ONLY PANEL
REQUIREMENTS
TYPICAL SIGN
12-03
9-08
B-3
B-2
B-1
A-3
A-2
A-1
CODE
ARROW DETAILS
for Large Ground-Mounted and Overhead Guide Signs
13.33" U/L and 12" Caps
13.33" U/L and 12" Caps
10.67" U/L and 10" Caps
10.67" U/L and 10" Caps
E-3
E-4
E-3 E-4
E5-1aT
E5-1bT
Down Arrow
16" & 20" U/L
16" & 20" U/L
paid for under "Aluminum Signs".
when specified in the plans. These signs will be
Furnish Type A aluminum sign attachments only
NUT/BOLT ATTACHMENTDIRECT APPLIED ATTACHMENT
("EXIT ONLY" AND "LEFT EXIT" PANELS, ROUTE MARKERS AND OTHER ATTACHMENTS)
MOUNTING DETAILS OF ATTACHMENTS TO GUIDE SIGN FACE
$TIME$$DATE$$FILE$---
--
-
PAVEMENT MARKINGS
TYPICAL STANDARD
PM(1)-12
2-12
WITH OR WITHOUT SHOULDERS
FOUR LANE TWO-WAY ROADWAY
CENTERLINE AND LANE LINES
FOUR LANE DIVIDED ROADWAY INTERSECTIONS
ROADWAYS WITH REDUCED SHOULDER
WIDTHS ACROSS BRIDGE OR CULVERT
YIELD LINES
GENERAL NOTES
1.
2.
40
45
EDGE LINE & CENTERLINE
GUIDE FOR PLACEMENT OF STOP LINES,
FOR POSTED SPEED ON ROAD BEING MARKED EQUAL TO OR GREATER THAN 45 MPH
FOR POSTED SPEED ON ROAD BEING MARKED EQUAL TO OR LESS THAN 40 MPH
30-45
4. The crosshatching is not required if delineators or barrier reflectors are used along the structure.
131
30'10'
L=
WS
60
2
Formula
L=WS
*
Pavement Edge
3" min.-4" max.
10" min.-12" max.
3" min.-4" max.
STOP LINES
Solid White
Width: 12" min.
24" max.
EDGE LINE
4" Solid White
CENTERLINE *
Length: 10'
Gap: 30'
* OPTIONAL
on approaches to
intersections
(500' min.)
30' max.
4' min.
30' max.
4' min.
8-95
4" Yellow Centerline
Edge Line
4" White
Yellow Line
4" Solid
Yellow Line
4" Solid
4" Yellow
4" Solid
Yellow line
may vary (typ.)
Shoulder width
may vary
Shoulder width
no shoulder exists (typ.)
6" min. when
Edgeline striping shall be as shown in the plans or as directed by the Engineer.
The traveled way includes only that portion of the roadway used for vehicular
travel and not the parking lanes, sidewalks, berms and shoulders. The traveled
two lane roadway.
5-00
(typ.)
6" min.
The edgeline should typically be placed a minimum of 6 inches from the edge of
ways shall be measured from the inside of edgeline to inside of edgeline of a
Edgelines are not required in curb and gutter sections of roadways.
Based on Traveled Way and Pavement Widths for Undivided Highways
Traveled Way Width 20'
for Edgelines
Minimum Requirements
Pavement Width 16' W 20'
for Centerlines without Edgelines
Minimum Requirements
pavement. This distance may vary due to pavement raveling or other conditions.
Posted Speed
*
S=Posted Speed (MPH)
L=Length of Crosshatching (FT.) W=Width of Offset (FT.)
5 foot increment.
Crosshatching length should be rounded up to nearest
traffic speeds normally exceed the posted speed limit.
85th Percentile Speed may be used on roads where
TABLE 1 - TYPICAL LENGTH (L)
2 L = 4(40) / 60 = 106.67 ft. rounded to 110 ft.
hatching should be:
2 feet on a 40 MPH roadway. The length of the cross-
A 4 foot shoulder in advance of a bridge reduces to
L = 8 x 70 = 560 ft.
hatching should be:
4 feet on a 70 MPH roadway. The length of the cross-
An 8 foot shoulder in advance of a bridge reduces to
EXAMPLES:
8-00
3 to 12"
24"
36"
3 to 12"
12"
18"
3-03
Texas Department of Transportation sion of this standard to other formats or for incorrect results or damages resulting from its use. kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conver-DISCLAIMER: The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of any FILE:DATE:Traffic Operations Division
DN:CK:DW:CK:C TxDOT
JOB
COUNTY
CONT SECT
DIST
REVISIONS HIGHWAY
SHEET NO.
22A
TXDOT TXDOT TXDOT TXDOTNovember 1978
Pavement Edge
8" Solid White Channelizing Line
12" max.
10" min.-
4" White Edge Line
4" White Lane Line
4" Solid Yellow Line
4" White Lane Line
4" White Edge Line
4" Yellow Edge Line
stop/yield line
edgeline to
48" min. from
4" Yellow Edge Line
Width
Median
Width
Median
12"-24" White Stop or Yield Line
The narrow median width will be the controlling width to determine if markings are required.
different between intersections, interchanges and of opposite approaches of the same intersection.
traveled way to edge of traveled way. The median excludes turn lanes. The median width might be
width is defined as the area between two roadways of a divided highway measured from edge of
bars and centerlines shall be placed when the median width is greater than 30 ft. The median
All medians shall be field measured to determine the location of necessary striping. Stop/Yield
30'10'
Pavement Edge
4" White Lane Line
Yellow Line
4" Solid 4" White Edge Line
48' only)
way greater than
(12" max. for traveled
3" min.-4" usual
6" min. (typ.)
30'10'
Pavement Edge
4" White Lane Line 4" Yellow Edge Line
4" White Edge Line
6" min. (typ.)
20' typ.
of Curb
or Face
Bridge Rail
Lane width greater than or equal to 11'
NOTES:
(L)
White edgeline
White edgeline
White
4"
Varies
24" typ.
12" min.
1. No-passing zone on bridge approach is optional but if used, it shall be a minimum 500 feet long.
4" Minimum
W
5. For guard fence details, refer elsewhere in the plans.
2. For crosshatching length (L) see Table 1.
3. The width of the offset (W) and the required crosshatching width is the full shoulder width in
advance of the bridge.
WITH OR WITHOUT SHOULDERS
ONE-WAY ROADWAY
EDGE LINE AND LANE LINES
TWO LANE TWO-WAY ROADWAY WITH OR WITHOUT SHOULDERS
MATERIAL SPECIFICATIONS
DMS-6130 BITUMINOUS ADHESIVE FOR PAVEMENT MARKERS
PAVEMENT MARKERS (REFLECTORIZED)
EPOXY AND ADHESIVES DMS-6100
DMS-4200
DMS-8200
DMS-8220
DMS-8240
TRAFFIC PAINT
HOT APPLIED THERMOPLASTIC
PERMANENT PREFABRICATED PAVEMENT MARKINGS
All pavement marking materials shall meet the
required Departmental Material Specifications
as specified by the plans.
o
PM(2)-12
RAISED MARKERS
$TIME$$DATE$$FILE$---
--
-
with a posted speed limit of 45 MPH or less.
Profile markings shall not be placed on roadways
RAISED PAVEMENT MARKERS
CENTERLINE AND LANE LINES FOR TWO-WAY LEFT TURN LANE
LANE LINES FOR ONE-WAY ROADWAY (NON-FREEWAY FACILITIES)
CENTERLINE FOR ALL TWO LANE ROADWAYS
GENERAL NOTES
1.
2.
toward normal traffic and red face toward wrong-way traffic.
Raised pavement markers Type II-C-R shall have clear face
height of 7 quarters.
equal to a stack of 5 quarters to a maximum
line and profile marking is approximately
A quick field check for the thickness of base
NOTE:4-92
80'
80'
1"-4"
1"-4"
80'40'40'40'
40'40'40'
Type II-A-A
Type I-C
Type II-A-A
Type II-A-A
Type I-C
Type II-A-A
Centerline Symmetrical around centerline
Continuous two-way left turn lane
CENTERLINE & LANE LINES
SEE DETAIL "C"
FOR FOUR LANE TWO-WAY HIGHWAYS
DETAIL "A"DETAIL "B"
Type I-C or II-C-R
Type I-C or II-C-R
1"-4"
REFLECTIVE RAISED PAVEMENT MARKERS
FOR VEHICLE POSITIONING GUIDANCE
4"
10'30'
USING REFLECTIVE PROFILE PAVEMENT MARKINGS
4"
12"+ 1"
3‚"+ ƒ"6"5•"+ •"
OPTIONAL 6" LANE LINE
OR6"
5•"+ •"
18"+ 1"
4" LANE LINE
REFLECTORIZED PROFILE
PATTERN DETAIL
12"+ 1"
4"
3‚" + ƒ"
OR
OPTIONAL 6" EDGE LINE OR CENTERLINE
On concrete pavements the raised pavement markers
SEE DETAIL "B"SEE DETAIL "A"
shall be placed in line with and midway between
All raised pavement markers placed in broken lines
the stripes.
should be placed to one side of the longitudinal
joints.
80'
1"-2"
1"-2"Type II-A-A
Type II-A-A
DETAIL "C"
4" EDGE LINE OR CENTERLINE
4"
4"
4"
POSITION GUIDANCE USING
REFLECTORIZED PROFILE
MARKINGS
5-00
2 to 3"2 to 3"2 to 3"
2 to 3"
in height
300 to 500 mil
CENTER OR EDGELINE
BROKEN LANE LINE
Raised pavement marker Type I-C, clear
face toward normal traffic, shall
be placed on 80-foot centers.
4"
4"
3-4"
8-00
Texas Department of Transportation sion of this standard to other formats or for incorrect results or damages resulting from its use. kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conver-DISCLAIMER: The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of any FILE:DATE:Traffic Operations Division
April 1977 DN:CK:DW:CK:C TxDOT
JOB
COUNTY
CONT SECT
DIST
REVISIONS HIGHWAY
SHEET NO.
22B
TXDOT TXDOT TXDOT TXDOT
2-08
2-10
SECTION A
o
o
Adhesive
Surface
Reflectorized
Type I (Top View)
Type II (Top View)
AA
AA
Surface
Roadway
25 min
35 max-
2-12
Surface
Reflectorized
MATERIAL SPECIFICATIONS
All pavement marking materials shall meet the
required Departmental Material Specifications
as specified by the plans.
DMS-6130
EPOXY AND ADHESIVES DMS-6100
DMS-4200
DMS-8200
DMS-8220
DMS-8240
TRAFFIC PAINT
HOT APPLIED THERMOPLASTIC
PERMANENT PREFABRICATED PAVEMENT MARKINGS
BITUMINOUS ADHESIVE FOR PAVEMENT MARKERS
PAVEMENT MARKERS (REFLECTORIZED)
132
$TIME$$DATE$$FILE$---
--
-
2-10
PM(3)-12
2-12TYPICAL TRANSITION FOR TWLTL
AND DIVIDED HIGHWAY
See Note 5
20'
Solid
4" Yellow
9'3'
TWO-WAY STREET
MINOR
9'3'
SEE DETAIL B
TRAFFIC PAINT
HOT APPLIED THERMOPLASTIC
PERMANENT PREFABRICATED PAVEMENT MARKINGS
broken
4" yellow
Type II-A-A Markers
Type II-A-A Markers
Varies
Dotted 8" white Lane Line
1 Mile (Auxiliary Lane)
Dotted 8" white Lane Line
4" yellow broken
4" yellow solid
broken
4" white
20'
48'Type I-C
48'Type I-C
Varies (See note 3)
Varies (See note 3)
1 Mile (Lane Drop)
Typical 12' Min.
Full Lane Width
by the Engineer in the field.
and Crosswalk shall be approved
Final placement of Stop Bar
DETAIL B
DETAIL A
unless stated elsewhere in the plans.
intersection or dedicated turn bay is not required
corridor. Repeating the marking after each
the beginning of a two-way left-turn lane within a
marking should be used at or just downstream from
6. A two-way left-turn (TWLT) lane-use arrow pavement
divided highways and raised medians.
lanes. Raised pavement marker Type II-C-R with
highways, flush medians and two way left turn
5. Raised pavement marker Type I-C with undivided
used.
Manual on Uniform Traffic Control Devices" may be
4. Other crosswalk paterns as shown in the "Texas
near the upstream end of the full-width turn lane.
for a short turn lane, it should be located at or
lane use arrow or word and arrow marking is used
the bay is greater than 180 feet. When a single
two sets of arrows should be used if the length of
3. When lane used word and arrow markings are used,
Sign Designs for Texas.
words and arrows as shown in the Standard Highway
lanes and turn bays for emphasis. Details for
or word and arrow markings may be used in other
of substantial length. Lane use arrow markings
arrow markings should be used in auxiliary lanes
become mandatory turn lanes. Lane use word and
where through lanes approaching an intersection
2. Lane use word and arrow markings shall be used
placement and details.
1. Refer elsewhere in plans for additional RPM
See note 6
TYPICAL TWLTL AT ONE-WAY STREET AND RIGHT TURN AUXILIARY LANE(ONE-WAY, NON-SIGNALIZED)MINOR CROSS STREETTYPICAL TWLTL AT TWO-WAY CROSS STREET AND RIGHT TURN LANE DROP(TWO-WAY, NON-SIGNALIZED)MINOR CROSS STREETMAJOR CROSS STREET4" yellow solid
spaced at 20'
Type II-A-A
8" white (Typ)
spaced at 20'
Type II-C-R
Type I-C or
SEE DETAIL C
SEE DETAIL C
TYPICAL TWO-LANE HIGHWAY INTERSECTION WITH LEFT TURN BAYS
30-45°
5-00
RURAL LEFT TURN BAYS
DIVIDED HIGHWAYS AND
TWO-WAY LEFT TURN LANES
PAVEMENT MARKINGS FOR
8-00
3-03
Texas Department of Transportation sion of this standard to other formats or for incorrect results or damages resulting from its use. kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conver-DISCLAIMER: The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of any FILE:DATE:Traffic Operations Division
April 1998 DN:CK:DW:CK:C TxDOT
JOB
COUNTY
CONT SECT
DIST
REVISIONS HIGHWAY
SHEET NO.
22C
TXDOT TXDOT TXDOT TXDOT
20'
SEE DETAIL A
20'
(typ.)
8" White
1" (Typ)
SEE DETAIL A
4" white broken
***
(typ.)
24" White
4" yellow broken
Varies based on length of turn bay
***Typically equal to • the length of storage lane
**
MATERIAL SPECIFICATIONS
All pavement marking materials shall meet the
required Departmental Material Specifications
as specified by the plans.
DMS-6130
EPOXY AND ADHESIVES DMS-6100
DMS-4200
DMS-8200
DMS-8220
DMS-8240
PAVEMENT MARKERS (REFLECTORIZED)
4" white broken
BITUMINOUS ADHESIVE FOR PAVEMENT MARKERS
20'ONLYONLYONLYONLYONLYONLYDETAIL C
Type II-A-A Markers
3-4"
3-4"20'
1'-6"
Stop Line
24" White
lines
crosswalk
12" White
typ.
4'min.
6'
Yellow Solid
4"
Yellow Solid
4"
32'typical
32'
Type I-C
solid
8" white
GENERAL NOTES
133
$TIME$$DATE$$FILE$---
--
-
PM(4)-12
8"
4"
8"
4"8'20' MIN.EX IT
765 B
GORE)
(PHYSICAL
GORE
BACK OF
MARKINGS
EXIT GORE
AERIAL VIEW DETAIL
GORE MARKINGS FOR
EXIT NUMBER
Texas Department of Transportation sion of this standard to other formats or for incorrect results or damages resulting from its use. kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conver-DISCLAIMER: The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of any FILE:DATE:Traffic Operations Division
April 2006 DN:CK:DW:CK:C TxDOT
JOB
COUNTY
CONT SECT
DIST
REVISIONS HIGHWAY
SHEET NO.
22D
TXDOT TXDOT TXDOT TXDOT
2-10
GENERAL NOTES
EXIT RAMPMAIN LANES2-12
or as specified in these plans.
required Departmental Material Specifications
4. All pavement marking materials shall meet the
elsewhere in the plans.
3. Pavement markings are to be located as specified
approximately 4 inches.
2. Spacing between letters and numbers should be
unless otherwise noted.
1. Minimum 8 foot white markings should be used,
EXIT
GORE
SIGN
134
EASTWEST
CURB & GUTTER OR RAISED ISLAND
SMD(GEN)-08
bolt length is 1 inch for aluminum.
nylon washer, flat washer and lock washer. The
5/16-18 UNC galvanized square head with nut,
Bolts used to mount sign panels to the clamp are
S80 = Schedule 80 Pipe (see SMD(SLIP-1) to (SLIP-3))
10BWG = 10 BWG Tubing (see SMD(SLIP-1) to (SLIP-3))
TWT = Thin-Walled Tubing (see SMD(TWT))
FRP = Fiberglass Reinforced Plastic Pipe (see SMD(FRP))
SB = Slipbase - Bolted Down (see SMD(SLIP-1) to (SLIP-3))
SA = Slipbase - Concreted (see SMD(SLIP-1) to (SLIP-3))
WP = Wedge Anchor Plastic (see SMD(TWT))
WS = Wedge Anchor Steel - (see SMD(TWT))
UB = Universal Anchor - Bolted down (see SMD(FRP) and (TWT))
UA = Universal Anchor - Concreted (see SMD(FRP) and (TWT))
EXAL = Extruded Aluminum Sign Panels (see SMD(SLIP-3))
WC = 1.12 #/ft Wing Channel (see SMD(SLIP-1) to (SLIP-3))
BM = Extruded Wind Beam (see SMD(SLIP-1) to (SLIP-3))
1EXT or 2EXT = Number of Extensions (see SMD(SLIP-1) to (SLIP-3), (TWT))
IF REQUIRED
U = Prefab. "U" (see SMD(SLIP-1) to (SLIP-3))
T = Prefab. "T" (see SMD(SLIP-1) to (SLIP-3), (TWT))
P = Prefab. "Plain" (see SMD(SLIP-1) to (SLIP-3), (TWT), (FRP))
9-08
135
SIGN LOCATION
PAVED SHOULDERS
LESS THAN 6 FT. WIDE
HIGHWAY
INTERSECTION
AHEAD
HIGHWAY
INTERSECTION
AHEAD
GREATER THAN 6 FT. WIDE
min
12 ft
7.0 ft min *
7.5 ft max
Lane
Travel
Shoulder
Paved
Lane
Travel
Shoulder
Paved
7.0 ft min *
7.5 ft max
0 to 6 ft
than 6 ft
Greater
6 ft min
the edge of the travel lane.
the sign must be placed at least 12 ft. from
When the shoulder is 6 ft. or less in width,
edge of the shoulder.
the sign must be placed at least 6 ft. from the
When the shoulder is greater than 6 ft in width,
HIGHWAY
INTERSECTION
AHEAD
HIGHWAY
INTERSECTION
AHEAD
BEHIND CONCRETE BARRIER
7.0 ft min *
7.5 ft max
Lane
Travel
Shoulder
Paved
Lane
Travel
Shoulder
Paved
7.0 ft min *
7.5 ft max
BEHIND GUARDRAIL
BEHIND BARRIER
5 ft min**2 ft min**
HIGHWAY
INTERSECTION
AHEAD
HIGHWAY
INTERSECTION
AHEAD
259 259
SIGNS WITH PLAQUES
7.0 ft min *
7.5 ft max
Lane
Travel
Shoulder
Paved
or secondary sign.
the supplemental plaque
measured to the bottom of
the 7 ft sign height is
or secondary sign is used,
When a supplemental plaque
Curb
Face of7.0 ft min *
7.5 ft max
min
2 ft
min
2 ft
Curb
Face of
7.0 ft min *
7.5 ft max
Lane
Travel
Shoulder
Paved
T-INTERSECTION
7.0 ft min *
7.5 ft max
6 ft min
Lane
Travel
Shoulder
Paved
ROW
Paved Shoulder
Edge of Travel Lane
that results in the greatest sign elevation:
* Signs shall be mounted using the following condition
(1)
(2)
the Engineer.
The maximum values may be increased when directed by
Post Type
Number of Posts (1 or 2)
Anchor Type
Sign Mounting Designation
TYPICAL SIGN ATTACHMENT DETAIL
Signs
Back-to-Back
3"
12 ft min
U-bolt
Sign Panel
Sign Post
Sign Post
Sign PanelClamp Bolt
Single Signs
SIGN SUPPORT DESCRIPTIVE CODES
RESTRICTED RIGHT-OF-WAY
(Descriptive Codes correspond to project estimate and quantities sheets)
edge of the travel lane or
a minimum of 7 to a maximum of 7.5 feet above the
Pipe Diameter
Approximate Bolt Length
3 or 3 1/2"
3 or 3 1/2"
4 1/2"
2" nominal
2 1/2" nominal
3" nominal 3 1/2 or 4"
3 1/2 or 4"
Rail
Guard
Barrier
Concrete
REQUIRED CLEARANCE
(i.e., typical space between wheel paths).
more than 4 inches above a 60-inch chord
when it is broken away, should not project
substantial remains of a breakaway support,
To avoid vehicle undercarriage snagging, any
Clamp
Sign
Clamp
Sign
or the universal clamp.
Sign clamps may be either the specific size clamp
Sign Panel
Specific Clamp Universal Clamp
Sign Bolt
nut
washer, lock washer,
Nylon washer, flat
nut
washer, lock washer,
Nylon washer, flat
nut
washer, lock washer,
Nylon washer, flat
washer
Nut, lock
washer
Nut, lock
Not Acceptable
Not AcceptableNot Acceptable
Acceptable
within a 7 ft. circle.
posts should be located
No more than 2 sign
circle
diameter
7 ft.
circle
diameter
7 ft.
circle
diameter
7 ft.
circle
diameter
7 ft.
**Sign clearance based on distance required for proper guard rail or concrete barrier performance.
***
installed on the backslope.
grade at the base of the support when sign is
a minimum of 7 to a maximum of 7.5 feet above the
STOP
Surface
Ground
TX-DOT
TEXAS
(i.e., stub).
support
portion of
Non-breakaway
4" max.
60"
FOR BREAKAWAY SUPPORT
depending upon field conditions.
right. The bolt length may need to be adjusted
sizes and sign clamp types are given in the table at
washer. The approximate bolt lengths for various post
head per ASTM A307 with nut and helical-spring lock
back-to-back, use a 5/16-18 UNC galvanized hex
When two sign clamps are used to mount signs
(When 6 ft min. is not possible.)
possible
Maximum
slope.
post could not be hit due to extreme
guardrail or if Engineer determines the
*** Post may be shorter if protected by
lane as practical.
should be placed as far from the travel
from the edge of the travel lane, signs
prevents the minimum horizontal clearance
In situations where a lateral restriction
factors.
buildings, a narrow island, or other
by rocks, water, vegetation, forest,
Right-of-way restrictions may be created
as close to ROW as practical.
be in line with the centerline of the roadway. Place
two way roadway, the right edge of the sign should
When this sign is needed at the end of a two-lane,
SM RD SGN ASSM TY XXXXX(X)XX(X-XXXX)
GENERAL NOTES & DETAILS
SMALL ROADSIDE SIGNS
SIGN MOUNTING DETAILS
http://www.txdot.gov/publications/traffic.htm
The website address is:
components and Wedge Anchor System components.
drawings of sign clamps, Triangular Slipbase System
See the Traffic Operations Division website for detailed
FT IN
LOW
CLEARANCE
14 4
M.P.H.
35
FARM
ROAD
EAST
3713
FARM
ROAD
EAST
3713
3
1
6
Texas Department of Transportation sion of this standard to other formats or for incorrect results or damages resulting from its use. kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conver-DISCLAIMER: The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of any $TIME$FILE:$DATE$$FILE$DATE:Traffic Operations Division
July 2002 DN:CK:DW:CK:C TxDOT
---
-
JOB
COUNTY
CONT SECT
DIST
REVISIONS
-
HIGHWAY
-
SHEET NO.
26A
TXDOT TXDOT TXDOT TXDOT
Slip Base
4" Max.
manufacturer
if required by
Washers
SMD(SLIP-1)-08
24" max.
12" min.
CONCRETE ANCHOR
GENERAL NOTES:
1. Slip base shall be permanently marked to indicate manufacturer. Method, design, and location of
marking are subject to approval of the TxDOT Traffic Standards Engineer.
2. Material used as post with this system shall conform to the following specifications:
10 BWG Tubing (2.875" outside diameter)
0.134" nominal wall thickness
Seamless or electric-resistance welded steel tubing or pipe
Steel shall be HSLAS Gr 55 per ASTM A1011 or ASTM A1008
Other steels may be used if they meet the following:
55,000 PSI minimum yield strength
70,000 PSI minimum tensile strength
20% minimum elongation in 2"
Wall thickness (uncoated) shall be within the range of 0.122" to 0.138"
Outside diameter (uncoated) shall be within the range of 2.867" to 2.883"
Galvanization per ASTM A123 or ASTM A653 G210. For precoated steel tubing (ASTM A653), recoat
tube outside diameter weld seam by metallizing with zinc wire per ASTM B833.
Schedule 80 Pipe (2.875" outside diameter)
0.276" nominal wall thickness
Steel tubing per ASTM A500 Gr C
Other seamless or electric-resistance welded steel tubing or pipe with equivalent
outside diameter and wall thickness may be used if they meet the following:
46,000 PSI minimum yield strength
62,000 PSI minimum tensile strength
21% minimum elongation in 2"
Wall thickness (uncoated) shall be within the range of 0.248" to 0.304"
Outside diameter (uncoated) shall be within the range of 2.855" to 2.895"
Galvanization per ASTM A123
3. See the Traffic Operations Division website for detailed drawings of sign clamps and Texas
Universal Triangular Slipbase System components. The website address is:
http://www.txdot.gov/publications/traffic.htm
4. Sign supports shall not be spliced except where shown. Sign support posts shall not be spliced.
ASSEMBLY PROCEDURE
Foundation
1. Prepare 12-inch diameter by 42-inch deep hole. If solid rock is encountered, the depth of the
foundation may be reduced such that it is embedded a minimum of 18 inches into the solid rock.
2. The Engineer may permit batches of concrete less than 2 cubic yards to be mixed with a portable,
motor-driven concrete mixer. For small placements less than 0.5 cubic yards, hand mixing in a
suitable container may be allowed by Engineer. Concrete shall be Class A.
3. Push the pipe end of the slip base stub into the center of the concrete. Rotate the stub back and
forth while pushing it down into the concrete to assure good contact between the concrete and stub.
Continue to work the stub into the concrete until it is between 2 to 4 inches above the ground.
4. Plumb the stub. Allow a minimum of 4 days to set, unless otherwise directed by the Engineer.
5. The triangular slipbase system is multidirectional and is designed to release when struck from any
direction.
Support
1. Cut support so that the bottom of the sign will be 7 to 7.5 feet above the edge of the travelway
(i.e., edge of the closest lane) when slip plate is below the edge of pavement or 7 to 7.5 feet
above slip plate when the slip plate is above the edge of the travelway. The cut shall be plumb and
straight.
2. Attach sign to support using connections shown. When multiple signs are installed on the same
support, ensure the minimum clearance between each sign is maintained. See SMD(SLIP-2) for
clearances based on sign types.
Concrete anchor consists of 5/8"
diameter stud bolt with UNC series
bolt threads on the upper end.
Heavy hex nut per ASTM A563, and
hardened washer per ASTM F436. The
stud bolt shall have a minimum
yield and ultimate tensile strength
of 50 and 75 KSI, respectively.
Nuts, bolts and washers shall be
galvanized per Item 445, "Galvaniz-
ing." Adhesive type anchors shall
have stud bolts installed with Type
III epoxy per DMS-6100, "Epoxies
and Adhesives." Adhesive anchors
may be loaded after adequate epoxy
cure time per the manufacturer's
recommendations. Top of bolt shall
extend at least flush with top of
the nut when installed. The anchor,
when installed in 4000 psi normal-
weight concrete with a 5 1/2"
minimum embedment, shall have a
minimum allowable tension and shear
of 3900 and 3100 psi, respectively.
2.5 cf of concrete.
should take approx.
plans). Foundation
elsewhere in the
unless noted
(shall be used
concrete footing
Non-reinforced
rod or #4 rebar.
7" x 1/2" diameter
Provide a
3/4 " diameter hole.
Class A concrete
provided to the Engineer by Contractor.
Installation procedures shall be
manufacturers' recommendations.
The devices shall be installed per
http://www.txdot.gov/business/producer list.htm
List for approved slip base systems.
Please reference the Material Producer
for the Triangular Slipbase System.
There are various devices approved
NOTE
9-08
6" min
or joint
to edge
Stub
Keeper Plate
Bolt
36"
42"
12" Dia
expansion or adhesive type.
50 ft-lbs). Anchor may be
5 1/2" and torque to min. of
8 places (embed a minimum of
5/8" diameter Concrete Anchor -
(See General Note 3)
Schedule 80 Pipe
10 BWG Tubing or
Post
TRIANGULAR SLIPBASE SYSTEM
SMALL ROADSIDE SIGNS
SIGN MOUNTING DETAILS
SM RD SGN ASSM TY XXXXX(X)SA(X-XXXX)
SM RD SGN ASSM TY XXXXX(X)SB(X-XXXX)
TRIANGULAR SLIPBASE INSTALLATION GENERAL REQUIREMENTS
2 1/2".
Bolt length is
Item 445 "Galvanizing."
galvanized per
or A449 and
(6) per ASTM A325
(3), and washers
bolts (3), nuts
5/8" structural
Texas Department of Transportation sion of this standard to other formats or for incorrect results or damages resulting from its use. kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conver-DISCLAIMER: The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of any $TIME$FILE:$DATE$$FILE$DATE:Traffic Operations Division
July 2002 DN:CK:DW:CK:C TxDOT
---
-
JOB
COUNTY
CONT SECT
DIST
REVISIONS
-
HIGHWAY
-
SHEET NO.
26B
TXDOT TXDOT TXDOT TXDOT
136
(R6-1) or
STOP (R1-1)
YIELD (R1-2)
0.25 H
1.75" max
1" min,
SIDE VIEW
T&U Bracket
48-inch STOP sign (R1-1)
60-inch YIELD sign (R1-2)
48x16-inch ONE-WAY sign (R6-1)
48-inch School X-ing sign (S2-1)
48-inch Advance School X-ing sign (S1-1)
5.
6.
7.
8.
9.
10.
11.
For horizontal rectangular signs fabricated from flat
Wing channel shall meet ASTM A 1011 SS Gr 50 and be
aluminum, T-brackets are used for signs 24 inches or
less in height. U-brackets are used for signs of
greater height.
SMD(SLIP-2)-08
(* - See Note 12)
(See Note 11)
12.Post open ends shall be fitted with Friction Caps.
(See SMD(2-1))
Extruded Alum. Windbeam
unless detailed otherwise.
All dimensions are in english
plans.
13.Sign blanks shall be the sizes and shapes shown on the
for 24 inch height signs. Place the clamp 3 inches above
9-08
Excess pipe, wing channel, or windbeam shall be cut
thickness shall be 24 gauge for all cap sizes.
Detail D
Detail F
REQUIRED SUPPORT
SIGN DESCRIPTION
48x60-inch signs
36x48, 48x36, and 48x48-inch signs
RegulatoryWarning48x48-inch signs (diamond or square)
48x60-inch signs
Large Arrow sign (W1-6 & W1-7)
1
1 •
4
1 •
1 •
W(max)=6FT
8
5W
W
39
8
8
H
W
W-39
2
W(max)=6FT
3838
•
40
1.12 #/ft Wing Channel
1 •
6 1
"U" Extender
11FT 9IN
(max)
0.2W
H
0.6W 0.2W
W
W(max)=8FT
SUPPORTPost
Detail E
STOP = 2 - 32 inch pieces
YIELD = 1 - 8 inch piece
& 1 - 32 inch piece
or
Extender
U-Bracket
lock washer.
washers and
bolt, nut, 2 flat
assembly and install
(through) after
Drill 7/16" hole
*
1 1/2"
ONE-WAY
Street Name
Sign
(if required)
Gap between
plaques
shall be
4 + 1
PLAQUE = 1 - variable length
2.
3.
4.
Sign supports shall not be spliced except where shown.
and 0.125 for signs greater than 15 sq. ft.
"REQUIRED SUPPORT" table on this sheet.
1.
abnormally high due to a fill slope.
GENERAL NOTES:
when impacted by an errant vehicle.
used in place of a 10 BWG where a sign height is
The Engineer may require that a Schedule 80 post be
Aluminum sign blanks shall conform to Departmental
Material Specifications DMS-7110 and shall have the
following minimum thicknesses: 0.080 for signs less
than 7.5 sq. ft., 0.100 for signs 7.5 to 15 sq. ft.,
Signs that require specific supports due to reasons
When two triangular slipbase supports are used to
support a single sign, they shall not be "rigidly"
connected to each other except through the sign panel.
This will allow each support to act independently
off so that it does not extend beyond the sign panel
(i.e., excess support shall not be visible when the
Additional route markers may be added vertically,
maximum allowable amount per Note 1.
Detail A
Detail B
Detail C
Side View
Top View
Top View
Item 445, "Galvanizing."
galvanized per
per ASTM A307
and flat washer
nut, lock washer
hex bolt with
5/16" x 3 3/4"
Channel
Wing
Channel
Wing
Channel
Wing
Panel
Sign
Aluminum
Panel
Sign
Aluminum
Sign support posts shall not be spliced.
galvanized per ASTM A 123.
provided the total sign area does not exceed the
sign is viewed from the front.) Repair galvanized
coating at cut support ends per Item 445, "Galvanizing."
SIGN SUPPORT # OF POSTS MAX. SIGN AREA
10 BWG 2 32 SF
Sch 80 1 32 SF
Sch 80 2 64 SF
10 BWG 1 16 SF
bottom of sign when possible.
Additional sign clamp required on the "T-bracket" post
TOP VIEW
Post
Universal)
(Specific or
Sign Clamp
(see SMD(2-1))
Windbeam
Aluminum
Extruded
Universal)
(Specific or
Sign Clamp
SM RD SGN ASSM TY XXXXX(1)XX(P)
SM RD SGN ASSM TY XXXXX(1)XX(P-BM)
SM RD SGN ASSM TY XXXXX(1)XX(U-WC)
SM RD SGN ASSM TY XXXXX(1)XX(U)
SM RD SGN ASSM TY XXXXX(1)XX(U)
SM RD SGN ASSM TY S80(1)XX(U-1EXT)SM RD SGN ASSM TY S80(1)XX(U-2EXT)
SM RD SGN ASSYM TY XXXXX(2)XX(P)
TY 10BWG(1)XX(P-BM)
TY 10BWG(1)XX(P-BM)
TY 10BWG(1)XX(P-BM)
SM RD SGN ASSM TY XXXXX(1)XX(T)
SM RD SGN ASSM TY XXXXX(1)XX(T)
TY 10BWG(1)XX(T)
TY 10BWG(1)XX(T)
TY 10BWG(1)XX(T)
TY 10BWG(1)XX(T)
TY S80(1)XX(T)
TY 10BWG(1)XX(T)
TY S80(1)XX(T)
TY 10BWG(1)XX(T)
TY 10BWG(1)XX(T)
TY 10BWG(1)XX(T)
TRIANGULAR SLIPBASE SYSTEM
SMALL ROADSIDE SIGNS
SIGN MOUNTING DETAILS
in addition to windloading are indicated on the
"Galvanizing."
Item 445,
A307 galvanized per
washers per ASTM
washer and 2 flat
hex bolt, nut, lock
1/2" x 4" heavy
"Galvanizing."
Item 445,
galvanized per
per ASTM A307
2 flat washers
nut, lock washer,
hex bolt with
5/16" x 1 3/4"
Nylon washer,
"Galvanizing."
Item 445,
galvanized per
per ASTM A307
2 flat washers
nut, lock washer,
hex bolt with
5/16" x 1 3/4"
Nylon washer,
"Galvanizing."
Item 445,
galvanized per
per ASTM A307
and 2 flat washers
nut, lock washer
hex bolt with
5/16" x 3/4"
Detail A
See
Detail B
See
Detail C
See
Universal)
(Specific or
Sign Clamp
Detail D
See
Splices shall only be allowed behind the sign substrate.
pipe diameter.)
clamp type and
depending on sign
length may vary
"Galvanizing." (Bolt
per Item 445
per ASTM A307 galvanized
washer and lock washer
head bolt, nut, flat
3/8" x 3 1/2" square
Detail E
See
Detail F
See
Item 445 "Galvanizing."
A307 galvanized per
and 2 flat washers per ASTM
bolt with nut, lock washer
3/8" x 3 1/2" heavy hex
+.05"
+.025"+.010"
-.025"+.010"
FRICTION CAP DETAIL
Skirt
Variation
Depth
engage pipe O.D.
Rolled Crimp to
Pipe O.D.
Pipe O.D.
Friction caps may be manufactured from hot rolled
or cold rolled steel sheets. The minimum sheet metal
The rim edges shall be reasonably straight and
smooth. Caps shall be sized and formed in such a
manner as to produce a drive-on friction fit and
have no tendency to rock when seated on the pipe.
The depth shall be sufficient to give positive
protection against entrance of rainwater. They
shall be free of sharp creases or indentations
and show no evidence of metal fracture.
Caps shall have an electrodeposited coating of
zinc in accordance with the requirements of ASTM
B633 Class FE/ZN 8.
Texas Department of Transportation sion of this standard to other formats or for incorrect results or damages resulting from its use. kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conver-DISCLAIMER: The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of any $TIME$FILE:$DATE$$FILE$DATE:Traffic Operations Division
July 2002 DN:CK:DW:CK:C TxDOT
---
-
JOB
COUNTY
CONT SECT
DIST
REVISIONS
-
HIGHWAY
-
SHEET NO.
26C
TXDOT TXDOT TXDOT TXDOT
137
(HDPE) System
Polyethylene
High Density
Wedge Anchor
Anchor
(Slip-2)
detail on SMD
or Plug. See
Friction Cap
0.25 H
Installation procedures shall be provided to the Engineer by Contractor.
The devices shall be installed per manufacturer's recommendations.
NOTE
SMD(TWT)-08
foundation.
turning in the
stub from
and prevents
the sign post
as a "stop" for
steel rod acts
1/2" x 7 1/2"
Concrete
Class A
Concrete
Class A
Concrete
Class A
9-08
Wedge
Stub pipe
Plastic Insert
See Detail A
27"
30"
12" Dia
10"
14"
30"
12" Dia
Post
Detail A
*
0.2W
H
0.6W
0.2W
W
W(max)=8FT
Note 4)
(See General
Post
Note 4)
(See General
Post
Sign Installation Using a Prefabricated T-Bracket for Thin-Wall Tubing Post
(* - See General Note 6)
T-Bracket
SM RD SGN ASSM TY TWT(X)WS(X)
SM RD SGN ASSM TY TWT(X)UA(P)
View A-A
reusability.
for optimal
ground
1/4" above
flush to
should be
Tubular socket
Socket
Tubular
(Approx.)
3"
of concrete.
approx. 2.0 cf
should take
Foundation
in the plans).
elsewhere
unless noted
(shall be used
Footing
Concrete
Non-reinforced
of concrete.
approx. 2.0 cf
should take
Foundation
in the plans).
elsewhere
unless noted
(shall be used
Footing
Concrete
Non-reinforced
(3" Nominal)
Stub Pipe
Schedule 40
Diameter
3 1/2"
(3" Nominal)
Stub Pipe
Schedule 40
Diameter
3 1/2"
Ring
Compression
(2" Nominal)
Wall Tube
0.095 Thin
2.375" Diameter
Spaced)
Slots (4 Equally
1/4 x 2 7/8"
A A
6" min
or joint
to edge
10"
10"Pipe Stub
Plate
Base
Coupler
3/4" dia.
1/2"
3 1/2"
Concrete anchor consists of 5/8" diameter stud bolt with
UNC series bolt threads on the upper end. A heavy hex nut
washers shall be galvanized per Item 445, "Galvanizing."
Adhesive type anchors shall have stud bolts installed with
Adhesive anchors may be loaded after adequate epoxy cure
per ASTM A563 and hardened washer per ASTM F436. The
time per the manufacturer's recommendations.
allowable tension and shear of 2450 and 1525 psi, respectively.
Top of bolt shall extend at least flush with top of nut when
installed. The anchor, when installed in 4000 psi normal-weight
concrete with a 3 3/8" minimum embedment, shall have a minimum
stud bolt shall have minimum yield and ultimate tensile
Type III epoxy per DMS-6100, "Epoxies and Adhesives."
SM RD SGN ASSM TY TWT(X)UB(P)
adhesive type.
expansion or
Anchor may be
to min. of 50 ft-lbs).
3 3/8" and torque
(embed a min. of
Anchor - 4 places
5/8" diameter Concrete
Note 4)
(See General
Post
used with the Bolt Down Universal Anchor System.
System. The insert should be cut to approx. 4 1/2" when
the bottom of the sign post when using the Universal Anchor
cover the tubing from just above the top of the stub pipe to
Anchor System. The insert should be approx. 10" long and
the Universal Anchor System or the Bolt Down Universal
Plastic insert must be used when using the TWT with either
with Thin-Walled Tubing Post
Universal Anchor System
A A
WITH THIN WALL TUBING POST
WEDGE & UNIVERSAL ANCHOR
SMALL ROADSIDE SIGNS
SIGN MOUNTING DETAILS
SM RD SGN ASSM TY TWT(X)XX(T)
12"
bolt.
post to accommodate
to be drilled through
9/16" hole may need
strengths of 50 and 75 ksi, respectively. Nuts, bolts and
"Galvanizing."
per Item 445,
galvanized
ASTM A307
washer per
and lock
flatwashers
bolt, nut, 2
heavy hex
1/2" x 4"
Wedge
17"
30"
SMD RD SGN ASSM TY TWT(X)WP(X)
(Approx.)
3"
of concrete.
approx. 2.0 cf
should take
Foundation
in the plans).
elsewhere
unless noted
(shall be used
Footing
Concrete
Non-reinforced
15"
Note 4)
(See General
Post
12" Dia
Steel System
Wedge Anchor GENERAL NOTES:
1. The Wedge Anchor System and the Universal Anchor System with thin wall tubing post
may be used to support up to 10 square feet of sign area.
2. The tubular socket, wedge and prefabricated T-bracket shall be permanently marked to
indicate manufacturer. Method, design, and location of marking are subject to the
approval of the TxDOT Traffic Standards Engineer.
3. Except for posts (13 BWG Tubing), clamps, nuts and bolts, all components shall be
prequalified. A list of prequalified vendors may be obtained from the Material
Producer List web page. The website address is:
http://www.txdot.gov/business/producer list.htm
4. Material used as post with this system shall conform to the following specifications:
13 BWG Tubing (2.375" outside diameter) (TWT)
0.095" nominal wall thickness
Seamless or electric-resistance welded steel tubing
Steel shall be HSLAS Gr 55 per ASTM A1011 or ASTM A1008
Other steels may be used if they meet the following:
55,000 PSI minimum yield strength
70,000 PSI minimum tensile strength
18% minimum elongation in 2"
Wall thickness (uncoated) shall be within the range of .083" to .099"
Outside diameter (uncoated) shall be within the range of 2.369" to 2.381"
Galvanization per ASTM 123 or ASTM A653 G210. For precoated steel tubing (ASTM
A653), recoat tube outside diameter weld seam by metallizing with zinc wire
per ASTM B833.
5. Sign blanks shall be the sizes and shapes shown on the plans.
6. Additional sign clamp required on the "T-bracket" post for 24" high signs. Place
clamp at least 3" above bottom of sign when possible.
7. Sign supports shall not be spliced except where shown. Sign support posts shall
not be spliced.
8. See the Traffic Operations Division website for detailed drawings of sign clamps
and Wedge Anchor System components. The website address is:
http://www.txdot.gov/publications/traffic.htm
WEDGE ANCHOR SYSTEM INSTALLATION PROCEDURE
1. Dig foundation hole. Where solid rock is encountered at ground level, the
foundation shall be a minimum depth of 18". When solid rock is encountered
below ground level, the foundation shall extend in the solid rock a minimum
depth of 18" or provide a minimum foundation depth of 30". If solid rock is
encountered, the socket/stub may be reduced in length as required to a minimum
length of 18". Any material removed from the socket/stub shall be from the
bottom and the clearance requirements given on SMD(GEN) must be followed. The
inner surfaces of the socket/stub must remain free of concrete or other debris.
2. The Engineer may permit batches of concrete less than 2 cubic yards to be mixed
with a portable, motor driven concrete mixer. For small placements less than
0.5 cubic yards, hand mixing in a suitable container may be allowed by Engineer.
Place concrete into hole until it is approximately flush with the ground.
Concrete shall be Class A.
3. Insert tubular socket into concrete until top of socket is approximaely 1/4 "
above the concrete footing.
4. Plumb the socket. Allow a minimum 4 days for concrete to set, unless otherwise
directed by Engineer..
5. Attach the sign to the sign post.
6. Insert the sign post into socket and align sign face with roadway.
7. Drive the wedge into the socket to secure post. This will leave approximately
3 inches of the wedge exposed.
UNIVERSAL ANCHOR SYSTEM INSTALLATION PROCEDURE
1. Dig foundation hole. Where solid rock is encountered at ground level, the
foundation shall be a minimum depth of 18". When solid rock is encountered
below ground level, the foundation shall extend in the solid rock a minimum
depth of 18" or provide a minimum foundation depth of 30". If solid rock is
encountered, the socket/stub may be reduced in length as required to a minimum
length of 18". Any material removed from the socket/stub shall be from the
bottom and the clearance requirements given on SMD(GEN) must be followed. The
inner surfaces of the socket/stub must remain free of concrete or other debris.
2. Insert base post in hole to depths shown and backfill hole with concrete.
3. Level and plumb the base post using a torpedo level and allow concrete adequate
time to set. The bottom of the slots provided in the stub pipe shall remain
above the top of the concrete foundation.
4. Attach the sign to the sign post.
5. Install plastic insert around bottom of post.
6. Insert sign post into base post. Lower until the post comes to rest on steel rod.
7. Seat compression ring using a hammer. Typically, the top of compression ring
will be approximately level with top of stub post when optimally installed.
8. Check sign post by hand to ensure it is unable to turn. If loose, increase the
tightening of the compression ring.
Texas Department of Transportation sion of this standard to other formats or for incorrect results or damages resulting from its use. kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conver-DISCLAIMER: The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of any $TIME$FILE:$DATE$$FILE$DATE:Traffic Operations Division
July 2002 DN:CK:DW:CK:C TxDOT
---
-
JOB
COUNTY
CONT SECT
DIST
REVISIONS
-
HIGHWAY
-
SHEET NO.
26E
TXDOT TXDOT TXDOT TXDOT
138
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
585 585
590 590
595 595
600 600
90+79.49
585 585
590 590
595 595
600 600
91+00.00
580 580
585 585
590 590
595 595
91+50.00
585 585
590 590
595 595
600 600
92+00.00
139
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:40:43 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
-53.69'TC 587.92'30.08'TC 588.49'2.76%3.05%EX. R.O.W.EX. R.O.W.UTILITY EASEMENTEX. PUBLIC 1.00%1.50%-55.67'TC 588.09'28.65'TC 588.40'2.98%EX. R.O.W.EX. R.O.W.UTILITY EASEMENTEX. PUBLIC FUTURE PROP. R.O.W.0.50%2.09%1.50%-55.63'TC 588.34'28.14'TC 588.38'2.82%EX. R.O.W.EX. R.O.W.UTILITY EASEMENTEX. PUBLIC0.50%FUTURE PROP. R.O.W.1.50%4:1 1.50%-52.08'TC 588.60'30.32'TC 588.60'2.58%EX. R.O.W.EX. R.O.W.UTILITY EASEMENTEX. PUBLICFUTURE PROP. R.O.W.0.50%1.50%1.50%
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
585 585
590 590
595 595
600 600
585 585
590 590
595 595
600 600
92+50.00
585 585
590 590
595 595
600 600
585 585
590 590
595 595
600 600
93+00.00
CL SIDEWALK CONNECTION RT
92+13.54
140
CL DRIVEWAY RT
92+79.18
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:40:43 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
-50.50'TC 588.67'30.93'TC 588.67'2.46%EX. R.O.W.EX. R.O.W.UTILITY EASEMENTEX. PUBLICFUTURE PROP. R.O.W.1.50%1.50%1.50%-45.04'TC 588.85'31.50'TC 588.85'1.50%2.53%EX. R.O.W.EX. R.O.W.UTILITY EASEMENTEX. PUBLICFUTURE PROP. R.O.W0.50%1.50%4:1-38.66'TC 589.00'1.63%2.40%EX. R.O.W.TD 588.59'TD 589.07'TD 589.16'TD 590.50'EX. R.O.W.G 588.50'31.00'37.00'43.00'60.83'7.53%
8%0.50%FUTURE PROP. R.O.W1.5%-34.06'TC 589.11'1.73%2.25%EX. R.O.W.EX. R.O.W.8%G 588.61'31.00'TD 588.69'37.00'TD 589.17'43.00'TD 589.26'4.14%TD 590.00'60.83'FUTURE PROP. R.O.W0.50%1.5%
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
585 585
590 590
595 595
600 600
93+50.00
585 585
590 590
595 595
600 600
94+00.00
585 585
590 590
595 595
600 600
94+50.00
580 580
585 585
590 590
595 595
141
CL DRIVEWAY RT
94+96.99
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:40:44 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
-25.78'TC 589.24'31.50'TC 589.24'1.95%1.97%EX. R.O.W.EX. R.O.W.EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W0.50%1.50%4:1-25.50'TC 589.11'31.50'TC 589.11'2.00%2.00%EX. R.O.W.EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W0.50%1.50%4:1-25.50'TC 588.99'31.50'TC 588.99'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W1.50%1.50%4:
1-25.50'TC 589.10'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.WTD 588.60'TD 589.08'TD 589.17'TD 586.87'31.00'37.00'43.00'72.24'7.87%
8%1.5%0.50%
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
580 580
585 585
590 590
595 595
95+00.00
585 585
590 590
595 595
600 600
95+50.00
585 585
590 590
595 595
600 600
96+00.00
580 580
585 585
590 590
595 595
96+50.00
142
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:40:45 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
-25.50'TC 589.11'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W8%TD 588.61'31.00'37.00'TD 589.09'43.00'TD 589.18'TD 586.84'72.24'8%
1.5%0.50%-25.50'TC 589.36'31.50'TC 589.36'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W1.50%4:
1
0.50%-25.50'TC 589.61'31.50'TC 589.61'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W1.50%4:10.50%-25.50'TC 589.86'31.50'TC 589.86'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W1.50%1.50%4:
1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
585 585
590 590
595 595
600 600
97+00.00
585 585
590 590
595 595
600 600
97+50.00
585 585
590 590
595 595
600 600
98+00.00
585 585
590 590
595 595
600 600
98+50.00
143
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:40:46 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
-25.50'TC 590.11'31.50'TC 590.11'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W1.50%4:
1
1.50%-25.50'TC 590.36'31.50'TC 590.36'2.00%2.00%EX. R.O.W.EX. R.O.W.1.50%1.50%4:1-25.50'TC 590.46'31.50'TC 590.46'2.00%2.00%EX. R.O.W.EX. R.O.W.4:11.50%1.50%4:1-25.50'TC 590.23'31.50'TC 590.23'2.00%2.00%EX. R.O.W.EX. R.O.W.4:11.50%1.50%4:
1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
585 585
590 590
595 595
600 600
99+00.00
585 585
590 590
595 595
600 600
585 585
590 590
595 595
600 600
99+50.00
585 585
590 590
595 595
600 600
SOUTHWEST CURB DUCHESS DRIVE
99+40.52
CL DUCHESS DRIVE
99+62.87
144
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:40:47 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
-25.50'TC 589.85'31.50'TC 589.85'2.00%2.00%EX. R.O.W.EX. R.O.W.4:
1
1.50%1.50%
2.00%2.00%EX. R.O.W.EX. R.O.W.8%
4.28%-25.00'TD 589.04'-31.00'TD 589.52'-43.00'TD 589.70'-72.72'TD 590.97'1.5%G 589.04'31.00'TC 590.56'1.57%96.12'1.50%TP 589.18'40.50'2.00%2.00%EX. R.O.W.EX. R.O.W.8%
4.25%-25.00'TD 588.97'TD 589.45'-31.00'TD 589.63'-43.00'TD 590.89'-72.72'1.5%G 588.97'31.00'TP 590.41'96.18'40.50'TP 589.18'1.50%2.33%
2.00%2.00%EX. R.O.W.EX. R.O.W.8%
3.93%-25.00'TD 588.87'TD 589.35'-31.00'TD 589.53'-43.00'TD 590.70'-72.72'1.5%31.00'G 588.87'40.50'TP 589.01'1.50%TP 590.87'96.28'3.33%
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
585 585
590 590
595 595
600 600
585 585
590 590
595 595
600 600
585 585
590 590
595 595
600 600
100+00.00
585 585
590 590
595 595
600 600
100+50.00
SOUTHEAST CURB DUCHESS DRIVE
99+85.71
145
CL DRIVEWAY LT
99+70.55
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:40:48 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
2.00%2.00%EX. R.O.W.EX. R.O.W.8%
4.16%-25.00'TD 588.81'TD 589.29'-31.00'TD 589.47'-43.00'TD 590.71'-72.72'1.5%1.50%40.50'TP 588.95'TP 588.81'31.00'3.12%TP 590.70'96.36'2.00%2.00%EX. R.O.W.EX. R.O.W.8%
4.55%-25.00'TD 588.70'TD 589.18'-31.00'TD 589.36'-43.00'TD 590.71'-72.72'1.5%TP 588.81'31.00'1.50%40.50'TP 588.95'2.65%TC 590.81'96.54'-25.50'TC 589.09'35.86'G 588.49'2.00%2.00%EX. R.O.W.EX. R.O.W.4:
1 1.50%4:1
1.50%-25.50'TC 588.71'31.50'TC 588.71'2.00%2.00%EX. R.O.W.EX. R.O.W.4:
1 1.50%1.50%4:1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
585 585
590 590
595 595
600 600
101+00.00
585 585
590 590
595 595
600 600
101+50.00
585 585
590 590
595 595
600 600
102+00.00
580 580
585 585
590 590
595 595
102+50.00
146
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:40:49 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
-25.50'TC 588.32'31.50'TC 588.32'2.00%2.00%EX. R.O.W.EX. R.O.W.4:
1 1.50%1.50%FUTURE PROP. R.O.W.4:1-25.50'TC 587.94'31.50'TC 587.94'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.1.50%1.5%
7.52%-31.00'-68.85'-56.85'588.02589.97'590.15'4:11.50%-25.50'TC 587.56'31.50'TC 587.56'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.1.50%1.50%4:14:
1 -25.50'TC 587.18'31.50'TC 587.18'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.1.50%1.50%
4:1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
580 580
585 585
590 590
595 595
103+00.00
580 580
585 585
590 590
595 595
103+50.00
580 580
585 585
590 590
595 595
104+00.00
580 580
585 585
590 590
595 595
104+50.00
147
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:40:50 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
-25.50'TC 586.80'31.50'TC 586.80'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.1.50%1.50%
4:
1 -25.50'TC 586.41'31.50'TC 586.41'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.1.50%1.50%
4:
1 4:1-25.50'TC 586.03'31.50'TC 586.03'2.00%2.00%EX. R.O.W.FUTURE PROP. R.O.W.1.50%1.50%4:14:
1
R.O.W.EX. -25.50'TC 585.65'31.50'TC 585.65'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.3:1 1.50%1.50%4:1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
580 580
585 585
590 590
595 595
105+00.00
580 580
585 585
590 590
595 595
105+50.00
580 580
585 585
590 590
595 595
580 580
585 585
590 590
595 595
106+00.00
148
CL DRIVEWAY RT
105+64.64
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:40:51 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
-25.50'TC 585.39'31.50'TC 585.20'1.33%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.1.50%1.50%-25.50'TC 585.13'31.50'TC 584.75'0.67%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.1.50%1.50%-25.50'TC 585.05'0.47%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.G 584.12'TD 584.60'TD 584.69'TD 585.02'31.00'37.00'43.00'52.75'8%3.43%1.50%1.5%-25.50'TC 584.87'31.50'TC 584.30'0.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.1.00%1.50%
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
580 580
585 585
590 590
595 595
106+50.00
580 580
585 585
590 590
595 595
107+00.00
580 580
585 585
590 590
595 595
575 575
580 580
585 585
590 590
107+50.00
149
CL DRIVEWAY RT
107+19.34
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:40:52 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
REFERENCE ONLY.
CROSS-SECTIONS SHOWN FOR
CONSTRUCTED BY OTHERS.
3. STA 106+00 TO STA 119+00 TO BE
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
-25.50'TC 584.61'31.50'TC 583.85'-0.67%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.1.50%
1.50%-25.50'TC 584.35'31.50'TC 583.40'-1.33%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.1.50%
1.50%4:1-25.50'TC 584.23'2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.8%TD 582.81'G 582.73'31.00'37.00'TD 583.31'43.00'TD 583.43'TD 584.12'52.20'-2.00%8%1.50%
1.5%4:131.50'TC 582.95'2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.-25.00'TD 584.13'-31.00'TD 584.31'-43.00'TD 584.94'-50.00'8%TD 583.65'G 583.57'-2.00%
8
.98%1.5%
1.5%4:1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
575 575
580 580
585 585
590 590
575 575
580 580
585 585
590 590
108+00.00
575 575
580 580
585 585
590 590
575 575
580 580
585 585
590 590
108+50.00
150
CL DRIVEWAY RT
108+08.75
CL DRIVEWAY LT
107+64.78
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:40:53 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
REFERENCE ONLY.
CROSS-SECTIONS SHOWN FOR
CONSTRUCTED BY OTHERS.
3. STA 106+00 TO STA 119+00 TO BE
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
31.50'TC 582.88'2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.-25.00'8%-31.00'TD 584.06'TD 584.24'-43.00'TD 584.74'-50.00'TD 583.58'G 583.50'-2.00%
7.13%1.50%
1.50%4:
1-25.50'TC 583.84'2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.0.98%TD 582.28'37.00'TD 582.34'43.00'TD 582.40'50.00'TD 582.47'G 582.2031.00'-2.00%
1.50%-25.50'TC 583.78'2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.TD 582.24'37.00'TD 582.41'43.00'TD 582.50'50.00'TD 582.61'1.50%2.90%-2.00%G 582.1631.00'1.50%-25.50'TC 583.59'31.50'TC 582.45'2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.-2.00%
1.50%
1.50%
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
575 575
580 580
585 585
590 590
575 575
580 580
585 585
590 590
109+00.00
575 575
580 580
585 585
590 590
575 575
580 580
585 585
590 590
109+50.00
151
CL DRIVEWAY RT
109+31.66
CL DRIVEWAY LT
108+73.87
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:40:54 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
REFERENCE ONLY.
CROSS-SECTIONS SHOWN FOR
CONSTRUCTED BY OTHERS.
3. STA 106+00 TO STA 119+00 TO BE
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
31.50'TC 582.33'2.00%EX. R.O.W.EX. R.O.W.-25.00'TD 583.03'G 582.95'-31.00'TD 583.51'TD 583.69'-43.00'-53.93'TD 584.47'-2.00%R.O.W.PROP. FUTURE 8%
4.49%1.50%
1.50%-25.50'TC 583.34'31.50'TC 582.20'2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.-2.00%FUTURE PROP. R.O.W.1.50%
1.50%
4:14:1-25.50'TC 583.16'2.00%EX. R.O.W.EX. R.O.W.TD 581.62'37.00'TD 581.53'TD 581.44'43.00'TD 581.01'50.00'-1.50%
-2.00%
-6.17%G 581.54'31.00'FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.1.50%
4:
1 -25.50'TC 583.09'-2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.G 581.45'31.00'TD 581.53'37.00'TD 581.44'43.00'TD 581.35'50.00'TD 581.12'-3.24%-1.50%
1.50%
4:
1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
575 575
580 580
585 585
590 590
575 575
580 580
585 585
590 590
110+00.00
575 575
580 580
585 585
590 590
575 575
580 580
585 585
590 590
110+50.00
152
CL DRIVEWAY LT
110+15.30
CL DRIVEWAY RT
109+88.88
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:40:55 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
REFERENCE ONLY.
CROSS-SECTIONS SHOWN FOR
CONSTRUCTED BY OTHERS.
3. STA 106+00 TO STA 119+00 TO BE
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
-25.50'TC 582.88'-2.00%2.00%EX. R.O.W.EX. R.O.W.TD 581.66'TD 581.75'TD 581.19'37.00'43.00'50.00'-8%5.32%TD 581.34'G 581.2631.00'FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.3:1 1.50%
1.5%31.50'TC 581.70'-2.00%2.00%EX. R.O.W.EX. R.O.W.-25.00'TD 582.41'G 582.32'8%-31.00'TD 582.89'10%-43.00'TD 583.07'-59.93'TD 584.76'FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.1.5%
1.50%31.50'TC 581.67'-2.00%2.00%EX. R.O.W.-25.00'TD 582.37'G 582.29'-31.00'TD 582.85'-43.00'TD 583.03'8%TD 584.63'-59.93'9
.46%FUTURE PROP. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.1.50%
1.50%-25.50'TC 582.82'31.50'TC 581.72'-2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.1.50%
1.50%
3:1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
575 575
580 580
585 585
590 590
575 575
580 580
585 585
590 590
111+00.00
575 575
580 580
585 585
590 590
111+50.00
575 575
580 580
585 585
590 590
112+00.00
153
CL DRIVEWAY RT
110+80.22
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:40:55 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
REFERENCE ONLY.
CROSS-SECTIONS SHOWN FOR
CONSTRUCTED BY OTHERS.
3. STA 106+00 TO STA 119+00 TO BE
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
-25.50'TC 583.03'-2.00%2.00%EX. R.O.W.EX. R.O.W.-1.50%G 581.41'31.00'TD 581.49'37.00'TD 581.40'43.00'TD 581.31'-6.32%50.00'TD 580.87'FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.4:
1 1.50%-25.50'TC 583.23'31.50'TC 582.09'-2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.1.50%
1.50%4:
1-25.50'TC 583.73'31.50'TC 582.59'-2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.0.50%FUTURE PROP. R.O.W.1.50%
3:1-25.50'TC 584.38'31.50'TC 583.09'-2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.1.50%
1.50%4:1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
580 580
585 585
590 590
595 595
580
580
585
585
590
590
580 580
585 585
590 590
NORTHWEST CURB MAYHILL ROAD
112+25.73
SOUTHWEST CURB MAYHILL ROAD
112+28.53
CL MAYHILL ROAD
112+75.57
0 10 20 30 40 50 60 70 80 90 100 110 120
575
575
150140130 160
154
575575
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:40:56 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
REFERENCE ONLY.
CROSS-SECTIONS SHOWN FOR
CONSTRUCTED BY OTHERS.
3. STA 106+00 TO STA 119+00 TO BE
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
EX. ON 0.50%TP 584.68'-59.85'58.20'TC 582.82'TC 580.23'138.54'EX. ON 4.68%EX. R.O.W.
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
580 580
585 585
590 590
595 595
580 580
585 585
590 590
580 580
585 585
590 590
595 595
113+50.00
NORTHEAST CURB MAYHILL ROAD
113+25.55
SOUTHEAST CURB MAYHILL ROAD
113+41.01
155
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:40:57 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
REFERENCE ONLY.
CROSS-SECTIONS SHOWN FOR
CONSTRUCTED BY OTHERS.
3. STA 106+00 TO STA 119+00 TO BE
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761TC 585.82'-83.87'EX. ON 0.89%TC 585.30'-49.17'66.66'TC 582.98'TC 581.40'112.33'EX. ON 5.40%-25.50'TC 585.05'31.50'TC 583.78'2.00%
-2.00%EX. R.O.W.4:11.50%
1.50%
4:1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
575 575
580 580
585 585
590 590
114+00.00
575 575
580 580
585 585
590 590
114+50.00
575 575
580 580
585 585
590 590
115+00.00
575 575
580 580
585 585
590 590
CL 5'x4' BOX CULVERT
115+26.63
156
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:40:58 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
REFERENCE ONLY.
CROSS-SECTIONS SHOWN FOR
CONSTRUCTED BY OTHERS.
3. STA 106+00 TO STA 119+00 TO BE
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
-25.50'TC 585.30'31.50'TC 584.10'2.00%-2.00%EX. R.O.W.EX. R.O.W.EX. DRAINAGE EASEMENT4:1 1.50%
1.50%4:
1-25.50'TC 585.55'31.50'TC 584.41'2.00%
-2.00%EX. R.O.W.EX. R.O.W.EX. DRAINAGE EASEMENTFUTURE PROP. R.O.W.4:1 1.50%4:
1
1.50%-25.50'TC 585.79'31.50'TC 584.78'2.00%
-1.56%EX. R.O.W.EX. R.O.W.EX. DRAINAGE EASEMENTFUTURE PROP. R.O.W.DRAINAGE EASEMENTFUTURE PROP.DRAINAGE EASEMENTFUTURE PROP.4:1 1.50%
1.50%4:
1-25.50'TC 585.78'31.50'TC 584.85'2.00%-1.32%EX. R.O.W.EX. R.O.W.EX. DRAINAGE EASEMENTFUTURE PROP. R.O.W.DRAINAGE EASEMENTFUTURE PROP. 2:15'x 4' BOX CULVERT ON 0.50% 2:11.50%
1.50%
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
575 575
580 580
585 585
590 590
115+50.00
575 575
580 580
585 585
590 590
116+00.00
575 575
580 580
585 585
590 590
116+50.00
575 575
580 580
585 585
590 590
117+00.00
157
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:40:59 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
REFERENCE ONLY.
CROSS-SECTIONS SHOWN FOR
CONSTRUCTED BY OTHERS.
3. STA 106+00 TO STA 119+00 TO BE
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
-25.50'TC 585.69'31.50'TC 584.80'2.00%-1.11%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.DRAINAGE EASEMENTFUTURE PROP.DRAINAGE EASEMENTFUTURE PROP.1.50%4:1 1.50%4:1-25.50'TC 585.08'31.50'TC 584.32'2.00%-0.67%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.1.50%4:
1
1.50%4:1 -25.50'TC 584.20'31.50'TC 583.57'2.00%-0.22%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.1.50%4:1
1.50%
4:1-25.50'TC 583.67'31.50'TC 583.16'2.00%0.22%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.1.50%
4:11.50%4:1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
575 575
580 580
585 585
590 590
117+50.00
575 575
580 580
585 585
590 590
575 575
580 580
585 585
590 590
118+00.00
575 575
580 580
585 585
590 590
118+50.00
158
CL DRIVEWAY LT
117+76.09
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:00 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
REFERENCE ONLY.
CROSS-SECTIONS SHOWN FOR
CONSTRUCTED BY OTHERS.
3. STA 106+00 TO STA 119+00 TO BE
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
-25.50'TC 583.52'31.50'TC 583.14'2.00%0.67%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.1.50%
4:11.50%4:131.50'TC 583.28'2.00%0.90%EX. R.O.W.EX. R.O.W.-25.00'TD 583.17'G 583.09'TD 583.65'-31.00'8%-43.00'TD 583.83'-65.00'TD 585.06'FUTURE PROP. R.O.W.R.O.W.PROP. FUTURE 5.56%
1.50%
4:11.50%-25.50'TC 583.72'31.50'TC 583.47'2.00%1.11%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.1.50%4:11.50%
4:1-25.50'TC 584.00'31.50'TC 583.87'2.00%1.56%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.1.50%1.50%4:1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
580 580
585 585
590 590
595 595
119+00.00
580 580
585 585
590 590
595 595
119+50.00
580 580
585 585
590 590
595 595
120+00.00
580 580
585 585
590 590
595 595
159
CL DRIVEWAY LT
120+29.07
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:01 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
REFERENCE ONLY.
CROSS-SECTIONS SHOWN FOR
CONSTRUCTED BY OTHERS.
3. STA 106+00 TO STA 119+00 TO BE
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
-25.50'TC 584.27'31.50'TC 584.27'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.1.50%1.50%4:1-25.50'TC 584.67'31.50'TC 584.67'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.1.50%1.50%-25.50'TC 585.07'31.50'TC 585.07'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.1.50%1.50%4:131.50'TC 585.28'2.00%2.00%EX. R.O.W.EX. R.O.W.8%-25.00'TD 583.17'G 583.09'TD 583.65'-31.00'-43.00'TD 583.83'8%-62.65'TD 587.09'FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.1.50%4:1
1.50%
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
580 580
585 585
590 590
595 595
120+50.00
580 580
585 585
590 590
595 595
580 580
585 585
590 590
595 595
121+00.00
580 580
585 585
590 590
595 595
121+50.00
160
CL DRIVEWAY LT
120+87.29
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:02 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
-25.50'TC 585.47'31.50'TC 585.47'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.1.50%4:11.50%
4:131.50'TC 585.77'2.00%2.00%EX. R.O.W.FUTURE PROP. R.O.W.TD 585.35'G 585.27'-25.00'-31.00'TD 585.83'TD 586.01'-43.00'8%R.O.W.PROP. FUTURE TD 586.82'-60.03'4.73%R.O.W.EX. 1.50%4:11.50%31.50'TC 585.87'2.00%2.00%EX. R.O.W.FUTURE PROP. R.O.W.8%-25.00'TD 585.45'G 585.37'TD 585.93'-31.00'8%TD 586.11'-43.00'-60.03'TD 587.48'R.O.W.PROP. FUTURE R.O.W.EX. 1.50%4:1
1.50%-25.50'TC 586.27'31.50'TC 586.27'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.1.50%4:
1 1.50%4:1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
580 580
585 585
590 590
595 595
580 580
585 585
590 590
595 595
122+00.00
580 580
585 585
590 590
595 595
122+50.00
580 580
585 585
590 590
595 595
123+00.00
161
CL DRIVEWAY LT121+96.22
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:03 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
31.50'TC 586.64'2.00%2.00%EX. R.O.W.FUTURE PROP. R.O.W.-25.00'TD 586.22'G 586.14'8%-31.00'TD 586.70'-43.00'TD 586.88'8%TD 588.11'-58.38'R.O.W.PROP. FUTURE R.O.W.EX. 1.50%1.50%31.50'TC 586.67'2.00%2.00%EX. R.O.W.FUTURE PROP. R.O.W.8%-25.00'TD 586.25'G 586.17'TD 586.73'-31.00'-43.00'TD 586.91'-58.38'TD 588.13'7.94%R.O.W.PROP. FUTURE R.O.W.EX. 1.50%1.50%-25.50'TC 586.93'31.50'TC 586.93'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.1.50%4:11.50%4:1-25.50'TC 587.19'31.50'TC 587.19'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.1.50%4:11.50%4:1UTILITY EASEMENTEX. PUBLIC
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
580 580
585 585
590 590
595 595
123+50.00
580 580
585 585
590 590
595 595
124+00.00
580 580
585 585
590 590
595 595
124+50.00
580 580
585 585
590 590
595 595
125+00.00
162
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:04 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
-25.50'TC 587.44'31.50'TC 587.44'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.4:11.50%1.50%
4:
1-25.50'TC 587.70'31.50'TC 587.70'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.1.50%1.50%4:1-25.50'TC 587.92'31.50'TC 587.92'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.1.50%1.50%
4:1-25.50'TC 587.89'31.50'TC 587.89'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.1.50%1.50%4:
1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
580 580
585 585
590 590
595 595
125+50.00
580 580
585 585
590 590
595 595
126+00.00
580 580
585 585
590 590
595 595
580 580
585 585
590 590
595 595
126+50.00
163
CL DRIVEWAY LT
126+41.32
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:05 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
-25.50'TC 587.66'31.50'TC 587.66'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.1.50%4:
1
1.50%-25.50'TC 587.42'31.50'TC 587.42'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.1.50%
4:
1
1.50%31.50'TC 587.21'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.8%-25.00'TD 586.80'G 586.71'-31.00'TD 587.28'-43.00'TD 587.46'1.83%TD 587.60'-50.75'1.50%4:11.50%-25.50'TC 587.18'31.50'TC 587.18'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.1.50%1.50%
4:1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
580 580
585 585
590 590
595 595
580 580
585 585
590 590
595 595
127+00.00
580 580
585 585
590 590
595 595
127+50.00
580 580
585 585
590 590
595 595
128+00.00
164
CL DRIVEWAY RT
126+85.55
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:06 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
-25.50'TC 587.22'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.TD 586.80'G 586.72'31.00'37.00'TD 587.10'43.00'TD 586.98'50.00'TD 585.08'-10%
-2%4.90%R.O.W.PROP. FUTURE 0.50%-25.50'TC 587.29'31.50'TC 587.29'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.0.50%1.50%4:
1-25.50'TC 587.24'31.50'TC 587.24'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.0.50%4:11.50%-25.50'TC 586.99'31.50'TC 586.99'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.1.50%1.50%4:1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
580 580
585 585
590 590
595 595
580 580
585 585
590 590
595 595
128+50.00
580 580
585 585
590 590
595 595
129+00.00
580 580
585 585
590 590
595 595
CL CARPENTER ROAD
128+17.95
165
CL DRIVEWAY LT
129+03.63
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:06 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
31.50'TC 586.90'2.00%2.00%EX. R.O.W.FUTURE PROP. R.O.W.G 586.40'25.00'TP 586.77'43.50'TP 587.49'59.51'4.50%2.00%4:
1
1.50%-25.50'TC 586.74'31.50'TC 586.74'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.1.50%1.50%4:
131.50'TC 586.49'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.-25.00'TD 586.07'G 585.99'TD 586.55'-31.00'8%-43.00'TD 586.73'-50.00'TD 587.29'7.93%1.50%1.50%4:131.50'TC 586.47'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.8%-25.00'TD 586.05'G 585.97'TD 586.53'-31.00'-43.00'TD 586.71'TD 587.33'-51.48'7
.33%1.50%1.50%4:
1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
580 580
585 585
590 590
595 595
129+50.00
580 580
585 585
590 590
595 595
580 580
585 585
590 590
595 595
130+00.00
580 580
585 585
590 590
595 595
130+50.00
166
CL DRIVEWAY LT
129+72.82
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:07 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
-25.50'TC 586.24'31.50'TC 586.24'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.1.50%1.50%4:131.50'TC 586.13'2.00%2.00%EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.8%-25.00'TD 585.72'G 585.63'TD 586.20'-31.00'TD 586.38'-43.00'TD 587.60'-55.27'10%R.O.W.EX. 1.50%1.50%4:1-25.50'TC 585.99'31.50'TC 585.99'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.1.50%1.50%
3:1 -25.50'TC 585.74'31.50'TC 585.74'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.1.50%1.50%
3:1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
580 580
585 585
590 590
595 595
131+00.00
580 580
585 585
590 590
595 595
580 580
585 585
590 590
595 595
580 580
585 585
590 590
595 595
131+50.00
NORTHWEST CURB RYAN WAY
131+07.23
CL RYAN WAY
131+47.51
167
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:08 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.EX. UTILITY EASEMENT-25.00'G 584.99'31.50'TC 585.49'2.00%2.00%1.50%1.50%EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.EX. UTILITY EASEMENT-25.00'G 584.95'31.50'TC 585.45'2.00%2.00%1.50%R.O.W.EX. -43.00'TP 585.22'-0.69%
(-)0.69%-54.96'TC 585.63'-81.25'TC 585.45'1.50%EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.EX. UTILITY EASEMENT-25.00'G 584.75'31.50'TC 585.25'2.00%2.00%1.00%R.O.W.EX. 1.57%-43.00'TP 584.93'-51.44'TC 585.55'1.50%EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.EX. UTILITY EASEMENT-25.00'G 584.74'31.50'TC 585.24'2.00%2.00%0.50%R.O.W.EX. 1.49%-43.00'TP 584.83'-56.02'TC 585.51'1.50%
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
580 580
585 585
590 590
595 595
580 580
585 585
590 590
595 595
132+00.00
580 580
585 585
590 590
595 595
132+50.00
580 580
585 585
590 590
595 595
NORTHEAST CURB RYAN WAY
131+75.98
168
CL DRIVEWAY RT
132+67.33
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:09 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.EX. UTILITY EASEMENT-25.00'G 584.61'31.50'TC 585.11'2.00%2.00%-51.65'TC 585.05'-82.76'TC 584.52'0.50%-43.00'TP 584.70'R.O.W.EX. -1.69%-1.69%1.50%-25.50'TC 584.99'31.50'TC 584.99'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.EX. UTILITY EASEMENT4:
1
1.50%-25.50'TC 584.74'2.00%2.00%EX. R.O.W.EX. R.O.W.TD 584.32'37.00'TD 584.50'43.00'TD 584.38'53.38'TD 583.34'FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.EX. UTILITY EASEMENT-10%
-2%G 584.24'31.00'2.92%1.50%-25.49'TC 584.65'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.DRAINAGE EASEMENTFUTURE PROP. EX. UTILITY EASEMENT53.32'TD 583.20'-10%43.00'TD 584.24'-2%TD 584.36'37.00'2.06%TD 584.23'G 584.15'31.00'1.50%4:1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
575 575
580 580
585 585
590 590
133+00.00
575 575
580 580
585 585
590 590
580 580
585 585
590 590
595 595
133+50.00
580 580
585 585
590 590
595 595
134+00.00
CL 3-6'x3' BOX CULVERT
133+03.41
169
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:10 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
-25.50'TC 584.49'31.50'TC 584.49'2.00%2.00%EX. R.O.W.EX. R.O.W.DRAINAGE EASEMENTFUTURE PROP. FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.EX. UTILITY EASEMENT1.50%1.50%
3:13:1 -25.50'TC 584.48'31.50'TC 584.48'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.DRAINAGE EASEMENTFUTURE PROP. FUTURE PROP. R.O.W.EX. UTILITY EASEMENT3-6'x3' BOX CULVERT ON 0.88%EX. 2-48" RCP
1.50%1.50%-25.50'TC 584.47'31.50'TC 584.47'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.DRAINAGE EASEMENTFUTURE PROP. EX. UTILITY EASEMENT4:11.50%4:1 1.50%-25.50'TC 584.82'31.50'TC 584.82'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.EX. UTILITY EASEMENT4:1 1.50%1.50%4:1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
580 580
585 585
590 590
595 595
134+50.00
580 580
585 585
590 590
595 595
135+00.00
585 585
590 590
595 595
600 600
135+50.00
585 585
590 590
595 595
600 600
170
CL DRIVEWAY LT
135+88.61
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:11 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
-25.50'TC 585.55'31.50'TC 585.55'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.EX. UTILITY EASEMENT1.50%1.50%-25.50'TC 586.43'31.50'TC 586.43'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.FUTURE PROP. R.O.W.EX. UTILITY EASEMENT1.50%1.50%-25.50'TC 587.31'31.50'TC 587.31'2.00%2.00%EX. R.O.W.EX. R.O.W.0.50%FUTURE PROP. R.O.W.EX. UTILITY EASEMENT4:11.50%31.50'TC 587.99'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.TD 587.82'TD 588.00'TD 590.07'-25.00'-31.00'-43.00'-84.45'G 587.49'TD 587.58'4%EASEMENTUTILITY EX. 5.00%
1.50%1.50%
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
585 585
590 590
595 595
600 600
136+00.00
585 585
590 590
595 595
600 600
136+50.00
585 585
590 590
595 595
600 600
137+00.00
585 585
590 590
595 595
600 600
137+50.00
171
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:12 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
31.50'TC 588.19'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.G 587.69'TD 587.77'-25.00'-31.00'TD 588.17'TD 588.35'-43.00'TD 590.41'-84.24'EASEMENTUTILITY EX. 6.58%1.50%1.50%
5.00%-25.50'TC 588.82'31.50'TC 588.82'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.EX. UTILITY EASEMENT1.50%4:11.50%
4:1-25.50'TC 589.20'31.50'TC 589.20'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.EX. UTILITY EASEMENT4:
1 1.50%1.50%4:1-25.50'TC 589.58'31.50'TC 589.58'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.EX. UTILITY EASEMENT4:11.50%1.50%4:1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
585 585
590 590
595 595
600 600
138+00.00
585 585
590 590
595 595
600 600
138+50.00
585 585
590 590
595 595
600 600
139+00.00
585 585
590 590
595 595
600 600
139+50.00
172
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:13 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
-25.50'TC 589.96'31.50'TC 589.96'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.EX. UTILITY EASEMENT4:11.50%1.50%4:1-25.50'TC 590.34'31.50'TC 590.34'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.EX. UTILITY EASEMENT1.50%1.50%4:13:1 -25.50'TC 590.72'31.50'TC 590.72'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.EX. UTILITY EASEMENT3:1
1.50%1.50%-25.50'TC 591.10'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.EX. UTILITY EASEMENTG 590.60'31.00'TC 590.92'43.50'3:1 1.50%
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
585 585
590 590
595 595
600 600
585 585
590 590
595 595
600 600
585 585
590 590
595 595
600 600
140+00.00
585 585
590 590
595 595
600 600
SOUTHWEST CURB GLENNGARY WAY
139+55.58
CL GLENNGARY WAY
139+78.36
SOUTHEAST CURB GLENNGARY WAY
140+02.00
173
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:14 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
-25.50'TC 591.14'2.00%2.00%EX. R.O.W.EX. R.O.W.EX. UTILITY EASEMENT-1.50%TP 590.46'43.00'TC 590.40'57.42'TC 589.24'87.47'G 590.64'31.00'-3.88%-3.88%
3:1 1.50%-25.50'TC 591.32'2.00%2.00%EX. R.O.W.EX. UTILITY EASEMENT-1.50%
-4.40%G 590.82'31.00'TP 590.64'43.00'84.81'TC 588.80'R.O.W.EX. 3:1 1.50%-25.50'TC 591.48'2.00%2.00%EX. R.O.W.EX. R.O.W.EX. UTILITY EASEMENT-2.00%
-4.97%G 590.98'31.00'TP 590.74'43.00'TP 588.76'82.77'1.50%-25.50'TC 591.50'2.00%2.00%EX. R.O.W.EX. R.O.W.EX. UTILITY EASEMENT-2.00%
-6.37%
-6.37%G 590.76'43.00'TC 589.83'65.34'TP 588.76'82.08'G 591.00'31.00'1.50%
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
585 585
590 590
595 595
600 600
140+50.00
585 585
590 590
595 595
600 600
141+00.00
585 585
590 590
595 595
600 600
141+50.00
585 585
590 590
595 595
600 600
142+00.00
174
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:15 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
-25.50'TC 591.86'31.50'TC 591.86'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.EX. UTILITY EASEMENT1.50%1.50%
4:1-25.50'TC 592.24'31.50'TC 592.24'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.0.50%EX. UTILITY EASEMENT1.50%4:
1-25.50'TC 592.62'31.50'TC 592.62'2.00%2.00%EX. R.O.W.EX. R.O.W.0.50%FUTURE PROP. R.O.W.EX. UTILITY EASEMENT1.50%3:131.50'TC 592.99'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.-25.00'-31.00'TD 592.80'-43.00'TD 592.98'-50.00'TD 593.08'1.50%5.05%G 592.49'EX. UTILITY EASEMENT4:11.50%
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
585 585
590 590
595 595
600 600
585 585
590 590
595 595
600 600
142+50.00
585 585
590 590
595 595
600 600
143+00.00
585 585
590 590
595 595
600 600
143+50.00
175
CL DRIVEWAY LT
142+04.57
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:15 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
31.50'TC 593.01'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.G 592.49'-25.00'4.67%TD 592.80'-31.00'1.50%-43.00'TD 592.98'TD 593.08'-50.00'EX. UTILITY EASEMENT4:11.50%-25.50'TC 593.11'31.50'TC 593.11'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.EX. UTILITY EASEMENT4:11.50%1.50%-25.50'TC 592.85'31.50'TC 592.85'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.1.50%
4:11.50%-25.50'TC 592.21'31.50'TC 592.21'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.1.50%4:11.50%
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
585 585
590 590
595 595
600 600
144+00.00
585 585
590 590
595 595
600 600
585 585
590 590
595 595
600 600
144+50.00
580 580
585 585
590 590
595 595
145+00.00
176
CL DRIVEWAY RT
144+18.85
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:16 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
-25.50'TC 591.19'31.50'TC 591.19'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.1.50%4:
1
1.50%-25.50'TC 590.71'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.TC 589.90'TC 589.99'TC 590.30'-50.00'TC 589.34'8%
5.07%G 590.2131.00'37.00'43.00'1.00%
1.5%-25.50'TC 589.92'31.50'TC 589.92'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.0.50%1.50%4:
1-25.50'TC 588.65'31.50'TC 588.65'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.0.50%1.50%4:1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
580 580
585 585
590 590
595 595
145+50.00
580 580
585 585
590 590
595 595
146+00.00
580 580
585 585
590 590
595 595
146+50.00
580 580
585 585
590 590
595 595
147+00.00
177
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:17 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
-25.50'TC 587.62'31.50'TC 587.62'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.1.00%1.50%
4:1-25.50'TC 586.90'31.50'TC 586.90'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.0.50%1.50%4:1-25.50'TC 586.47'31.50'TC 586.47'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.0.50%1.50%4:
1-25.50'TC 586.12'31.50'TC 586.12'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.0.50%1.50%4:1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
575 575
580 580
585 585
590 590
147+50.00
575 575
580 580
585 585
590 590
148+00.00
575 575
580 580
585 585
590 590
148+50.00
575 575
580 580
585 585
590 590
149+00.00
178
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:18 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
-25.50'TC 585.76'31.50'TC 585.76'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.0.50%4:
1
1.50%-25.50'TC 585.41'31.50'TC 585.41'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.0.50%
4:11.50%-25.50'TC 585.06'31.50'TC 585.06'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.0.50%4:
1
1.50%-25.50'TC 584.71'31.50'TC 584.71'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.0.50%
4:11.50%
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
575 575
580 580
585 585
590 590
149+50.00
575 575
580 580
585 585
590 590
575 575
580 580
585 585
590 590
150+00.00
575 575
580 580
585 585
590 590
NORTHWEST CURB S FORK DRIVE
149+98.59
CL S FORK DRIVE
150+23.45
179
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:19 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
-25.50'TC 584.35'31.50'TC 584.35'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.0.50%4:
1
1.50%31.50'TC 584.01'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.G 583.51'TP 583.60'-0.82%TC 584.00'TC 583.94'-0.82%0.50%-25.00'-43.00'-55.20'-62.32'4:11.50%31.50'TC 584.00'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.G 583.50'0.50%TP 583.59'TP 583.19'-2.05%-25.00'-43.00'-62.30'1.50%
4:131.50'TC 583.88'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.G 583.38'-0.50%TP 583.29'-1.82%TP 582.95'-25.00'-43.00'-62.07'1.50%
4:1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
575 575
580 580
585 585
590 590
575 575
580 580
585 585
590 590
150+50.00
575 575
580 580
585 585
590 590
151+00.00
575 575
580 580
585 585
590 590
151+50.00
NORTHEAST CURB S FORK DRIVE
150+47.89
180
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:20 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
31.50'TC 583.76'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.-1.50%G 583.26'TP 582.99'TC 583.21'TC 583.07'(-)2.22%(-)2.22%-25.00'-43.00'-55.53'-61.84'1.50%4:131.50'TC 583.75'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.G 583.25'-25.00'1.50%4:1TC 583.47'-44.51'-1.50%-25.50'TC 583.50'31.50'TC 583.50'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.1.50%4:11.50%3:1 -25.50'TC 583.25'31.50'TC 583.25'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.DRAINAGE EASEMENTFUTURE PROP. 1.50%4:
1
1.50%4:1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
570 570
575 575
580 580
585 585
575 575
580 580
585 585
590 590
152+00.00
575 575
580 580
585 585
590 590
152+50.00
575 575
580 580
585 585
590 590
153+00.00
CL 3-7'x3' BOX CULVERT
151+93.80
181
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:21 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761-25.50'TC 583.03'31.50'TC 583.03'2.00%2.00%EX. R.O.W.DRAINAGE EASEMENTFUTURE PROP. 3-7'x3' BOX CULVERT ON 0.20%EX. 3-36" CMP
PROP. R.O.W.FUTURE 1.50%1.50%R.O.W.EX. 4.35'X 4' RCB
EX. -25.50'TC 583.00'31.50'TC 583.00'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.DRAINAGE EASEMENTFUTURE PROP.DRAINAGE EASEMENTFUTURE PROP.1.50%
3:1
4:1 1.50%-25.50'TC 582.78'31.50'TC 582.78'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.DRAINAGE EASEMENTFUTURE PROP.4:
1
1.50%1.50%3:1 -25.50'TC 582.93'31.50'TC 582.93'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.0.50%
4:11.50%3:1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
575 575
580 580
585 585
590 590
153+50.00
575 575
580 580
585 585
590 590
154+00.00
575 575
580 580
585 585
590 590
154+50.00
575 575
580 580
585 585
590 590
155+00.00
182
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:22 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
-25.50'TC 583.21'31.50'TC 583.21'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.0.50%1.50%
4:13:1 -25.50'TC 583.50'31.50'TC 583.50'2.00%2.00%EX. R.O.W.EX. R.O.W.FUTURE PROP. R.O.W.0.50%1.50%4:13:1EX. R.O.W.EX. R.O.W.ATMOS FENCEFUTURE PROP. R.O.W.(-)1.50%1.50%
4:1EX. R.O.W.EX. R.O.W.ATMOS FENCEFUTURE PROP. R.O.W.1.50%1.50%4:1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
575 575
580 580
585 585
590 590
155+50.00
575 575
580 580
585 585
590 590
156+00.00
575 575
580 580
585 585
590 590
156+50.00
575 575
580 580
585 585
590 590
157+00.00
183
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:23 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE 1.50%1.50%
4:1EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE 0.50%1.50%4:
1EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE 1.50%1.50%
4:1EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE 1.50%1.50%4:
1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
580 580
585 585
590 590
595 595
157+50.00
580 580
585 585
590 590
595 595
158+00.00
580 580
585 585
590 590
595 595
158+50.00
580 580
585 585
590 590
595 595
184
CL DRIVEWAY LT
158+67.23
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:24 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE1.50%1.50%
4:1EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE 1.50%1.50%
4:1EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE 1.00%1.50%4:1EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE 1.50%
4:1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
580 580
585 585
590 590
595 595
159+00.00
580 580
585 585
590 590
595 595
159+50.00
580 580
585 585
590 590
595 595
160+00.00
585 585
590 590
595 595
600 600
160+50.00
185
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:25 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP.FUTURE1.50%1.50%EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE 1.50%1.50%EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE 1.50%1.50%EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE 0.50%1.50%
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
585 585
590 590
595 595
600 600
161+00.00
585 585
590 590
595 595
600 600
161+50.00
585 585
590 590
595 595
600 600
162+00.00
585 585
590 590
595 595
600 600
162+50.00
186
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:25 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE 1.00%1.50%4:1EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE 1.50%1.50%
4:1EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE 1.50%1.50%4:1EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE 1.50%1.50%4:
1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
585 585
590 590
595 595
600 600
163+00.00
585 585
590 590
595 595
600 600
163+50.00
585 585
590 590
595 595
600 600
164+00.00
590 590
595 595
600 600
605 605
164+50.00
187
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:26 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE 1.50%1.50%4:1EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE 1.50%1.50%4:1EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE 1.00%1.50%4:1EX. R.O.W.ATMOS FENCE0.50%1.50%4:
1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
590 590
595 595
600 600
605 605
585 585
590 590
595 595
600 600
165+00.00
590 590
595 595
600 600
605 605
590 590
595 595
600 600
605 605
165+50.00
CL ORR ROAD
164+65.02
188
CL DRIVEWAY LT
165+34.65
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:27 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
EX. R.O.W.EX. R.O.W.0.50%EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE 1.50%1.50%
3:1EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE 1.50%
3:1EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE 1.50%1.50%
3:1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
590 590
595 595
600 600
605 605
166+00.00
590 590
595 595
600 600
605 605
166+50.00
590 590
595 595
600 600
605 605
167+00.00
590 590
595 595
600 600
605 605
167+50.00
189
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:28 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE 1.50%1.50%
3:1EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE 1.50%1.50%
3:1EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE 1.50%1.50%4:1EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE 1.50%1.50%
4:
1
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
590 590
595 595
600 600
605 605
168+00.00
585 585
590 590
595 595
600 600
168+50.00
585 585
590 590
595 595
600 600
169+00.00
585 585
590 590
595 595
600 600
169+50.00
190
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:29 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE 1.50%1.50%EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE 1.50%1.50%EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE 1.50%1.50%EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE 1.50%
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
585 585
590 590
595 595
600 600
170+00.00
585 585
590 590
595 595
600 600
170+50.00
585 585
590 590
595 595
600 600
171+00.00
585 585
590 590
595 595
600 600
171+50.00
191
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:30 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE 1.50%EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE 1.50%EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE 1.50%EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
00 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100 110110 120120
585 585
590 590
595 595
600 600
172+00.00
580 580
585 585
590 590
595 595
172+50.00
580 580
585 585
590 590
595 595
173+00.00
580 580
585 585
590 590
595 595
173+50.00
192
APPROVED
Huitt-Zollars, Inc.1717 McKinney Avenue, Suite 1400
NO.REVISIONSDATE
Dallas, Texas 75202
DRAWNDESIGN
KAR
APPR.
ROADWAY CROSS-SECTIONS
BDE
PROJ. NO.DATE
Phone (214) 871-3311 Fax (214) 871-0757
SCALE
SEP
2019 R305837
SHEET
1"=20'H
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn1:204:41:31 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLCITY OF DENTON
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-XSC01.dgn
1"=10'V
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
R.O.W. BY CITY OF DENTON.
ACQUISITION OF
PATH TO BE COMPLETED UPON
FOR FUTURE SIDEWALK AND BIKE/PED
2. CONSTRUCTION OF AND GRADING
COMPLETED WITHIN EXISTING R.O.W.
1. ALL BASE BID WORK TO BE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
FIRM REGISTRATION NO. F-761
EX. R.O.W.EX. R.O.W.ATMOS FENCER.O.W.PROP. FUTURE EX. FENCEEX. R.O.W.EX. R.O.W.ATMOS FENCEFUTURE PROP. R.O.W.EX. FENCEEX. R.O.W.EX. R.O.W.ATMOS FENCEFUTURE PROP. R.O.W.EX. FENCEEX. R.O.W.EX. R.O.W.ATMOS FENCEFUTURE PROP. R.O.W.EX. FENCE
DRAINAGE AREA MAP
1:200
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDA01.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDA01.dgn1:2004:41:46 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
V
V
V
V
D
D
D
D
D
LT
LT
LT
LT
LT
87+00 88+00 89+00 90+00
91+00
92+00
93+00
94+00
95+00
96+00
97+00
98+00
99+00
100+00
101+00
102+00
103+00
104+00
105+00 106+00 107+00 108+00 109+00 110+00 111+00 112+00 113+00 114+00 115+00 116+00
POT 10063+57.65
D
D
D
D
D
D
D
D
C-02
0.52
4.81
C-03
0.38
3.51
C-06
9.61
25.08
C-05
0.48
4.47
C-08
7.16
18.68
C-14
0.15
1.36
C-15
1.29
11.89
C-18
0.25
2.32
592
606
604
602
608
610
612
616
618 620622624
626
628
6126
26
618614
610
610
594 608606
604
606
608
610598592590596594598 602606612620616612612614
6146166086046
0
0
5
9
8
598600
608606 604602
598
608
598600
596594
596
594
590
612
610
588
6
1
0
600
614
634
634
632
632
634630628624622620614630630610616608606
608
628
616
610
602
606606600598604
600
624
594586
584582580578576
574
588
McKINNEY STREET
McKINNEY
STREET
DRIVEDUCHESSS MAYHI
LL ROADN MAYHI
LL ROADC-07
0.22
1.99
C-09
0.43
3.99
C-11
0.46
4.20 9.67
1.13
C-12
C-13
0.19
1.53
10.79
1.17
C-17
588
598
610
LEGEND:
DIRECTION OF FLOW
AREA DIVIDE
PROPOSED DRAINAGE
A-01 DRAINAGE AREA IDENTIFIER
AREA (ACRES)
EXISTING 2' CONTOUR
100 YEAR Q (CFS)
1.58
5.09
594592590
5945965985
9
2
588590
588586
586
584582584586582
580
586
578
582
580
5845 88
590
588
588
588
590588590
588
590
B-01
0.63
5.84
A-01
0.75
6.91
A-02
2.40
19.40
A-04
0.39
3.64
B-02
0.47
4.36
588
5
8
8
590
588N LOOP 288S LOOP 288STREET
McKINNEY 588590
SCALE IN FEET
50 2001001500
C-01
1.05
4.43*
A-03
2.29
7.84*
C-04
0.22
2.00
586584588 596
592
588
8.37
2.82
C-10
C-16
0.48
4.43
TO THE EAST
FOR DRAINAGE AREAS
SEE NEXT SHEET
193
A-05
0.05
0.48
DRAINAGE AREA MAP
1:200
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDA02.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDA02.dgn1:2004:41:50 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
D
D
D
D
111+00 112+00 113+00 114+00 115+00 116+00 117+00 118+00 119+00 120+00 121+00 122+00 123+00 124+00 125+00 126+00 127+00 128+00 129+00 130+00 131+00 132+00 133+00 134+00 135+00 136+00 137+00
D
D
D
D
D
McKINNEY STREET RYAN WAYCARPENTER ROADN MAYHI
LL ROADMcKINNEY STREET
LEGEND:
DIRECTION OF FLOW
AREA DIVIDE
PROPOSED DRAINAGE
A-01 DRAINAGE AREA IDENTIFIER
AREA (ACRES)
EXISTING 2' CONTOUR
100 YEAR Q (CFS)
1.58
5.09
SCALE IN FEET
50 2001001500
TO THE WEST
FOR DRAINAGE AREAS
SEE PREVIOUS SHEETS MAYHI
LL ROADTO THE EAST
FOR DRAINAGE AREAS
SEE NEXT SHEET
194586E-01
0.27
2.49
HIGH SCHOOL
BILLY RYAN
3.15
0.34
G-02
G-01
0.66
6.08
3.46
0.70
H-04
3.25
0.66
H-06
7.86
1.59
H-05
6.10
1.23
H-09
7.23
0.78
H-10
18.69
2.02
H-11
6.50
0.70
I-02
2.71
0.29
H-07
3.93
0.43
H-08
I-01
63.65
355.00
608
606
608
600
606610 614616620622624628630632634
598
588
634
630
610
602
606
624
634
632
628616630 606602
598
594
608
604
590
592
600
598
594
596
5785765805
8
2
582
582
582
5
8
2
5
8
4586 5
8
8
5
84
584
580618616614
612
610610608
606604
602608608596
600
592
5
90
588606606
606602
6
0
2
604
602
600 598
596
5
9
8600602
596
594
592608
606
606608610612
614616
618
598600602612616
622
596582592594
5
7
8 6046
04
6
0
6
5
8
4
590
5
9
2
598 5982.56
0.28
J-00
1.93
0.21
H-12
25.88
5.23
H-01
2.86
0.31
H-02
2.49
0.27
H-03
4.93
0.53
G-04
13.60
2.75
G-06
29.97
6.06
G-05
F-01
12.99
89.95
9.49
1.92
G-03
DRAINAGE AREA MAP
1:200
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDA03.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDA03.dgn1:2004:41:54 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
V D
D
131+00 132+00 133+00 134+00 135+00 136+00 137+00 138+00 139+00 140+00 141+00 142+00 143+00 144+00 145+00 146+00 147+00 148+00 149+00 150+00 151+00 152+00 153+00 154+00 155+00 156+00 157+00 158+00 159+00 160+00
D
D
D
195RYAN WAYWAYGLENNGARYMcKINNEY STREET
LEGEND:
DIRECTION OF FLOW
AREA DIVIDE
PROPOSED DRAINAGE
A-01 DRAINAGE AREA IDENTIFIER
AREA (ACRES)
EXISTING 2' CONTOUR
100 YEAR Q (CFS)
1.58
5.09
SCALE IN FEET
50 2001001500
TO THE WEST
FOR DRAINAGE AREAS
SEE PREVIOUS SHEET
590
598
600 594590606
610
590
594
598
604
608
590594598
586586
590
594
59
2582
578580
584
588
588
578
5
8
0
576
576
586
584
588
574
584
HIGH SCHOOL
BILLY RYAN
4.58
0.82
J-05
6.10
0.90
J-01
4.54
0.83
J-03
4.74
0.86
J-04
3.86
0.42
K-02
4.31
0.47
K-03
3.31
0.36
K-04
4.27
0.46
M-01
6.15
0.67
M-03
3.13
0.34
M-04
2.91
0.32
K-05
1.18
0.13
K-06
McKINNEY STREETS FORK DRIVE618
60
2602
616
586
582584
614
612
610598
596
594
4.17
0.45
K-01 4.06
0.44
M-02
350.10
78.86
L-01
6.32
0.68
J-02
2.10
0.23
J-06
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
196
DESIGN OF THIS POND WAS FOR THE OAK HILL BUSINESS PARK IN JULY, 2007.
TO RELEASE 7.84 CFS IN A 100 YEAR STORM.
* DRAINAGE AREA A-03 CONTAINS AN EXISTING DETENTION POND THAT WAS DESIGNED
DESIGN OF THIS POND WAS FOR THE OAK HILL BUSINESS PARK IN JULY, 2007.
TO RELEASE 4.43 CFS IN A 100 YEAR STORM.
**DRAINAGE AREA C-01 CONTAINS AN EXISTING DETENTION POND THAT WAS DESIGNED
DESIGN OF THIS POND WAS FOR RYAN HIGH SCHOOL IN NOVEMBER, 2009.
TO RELEASE 355 CFS IN A 100 YEAR STORM.
*** DRAINAGE AREA I-01 CONTAINS AN EXISTING DETENTION POND THAT WAS DESIGNED
DESIGN OF THIS POND WAS FOR THE MEADOWS SUB-DIVISION IN APRIL, 1985.
TO RELEASE 340.07 CFS IN A 100 YEAR STORM.
****DRAINAGE AREA L-01 CONTAINS AN EXISTING DETENTION POND THAT WAS DESIGNED
*
**
***
****
McKINNEY STREET PHASE TWO RUNOFF CALCULATIONS
TOTAL AREA WEIGHTED INTENSITY FACTOR
FREQUENCY "Q-100"
AREA "A""C"Tc "I-100"RUNOFF
NO. (ACRES)VALUE (MIN.)(IN./HR)fC (CFS)
A-01 0.75 0.90 10.00 9.24 1.11 6.91
A-02 2.40 0.70 10.00 9.24 1.25 19.40
A-03 2.29 0.80 10.00 9.24 1.25 7.84
A-04 0.39 0.90 10.00 9.24 1.11 3.64
A-05 0.05 0.90 10.00 9.24 1.11 0.48
B-01 0.63 0.90 10.00 9.24 1.11 5.84
B-02 0.47 0.90 10.00 9.24 1.11 4.36
C-01 1.05 0.80 10.00 9.24 1.25 4.43
C-02 0.52 0.90 10.00 9.24 1.11 4.81
C-03 0.38 0.90 10.00 9.24 1.11 3.51
C-04 0.22 0.90 10.00 9.24 1.11 2.00
C-05 0.48 0.90 10.00 9.24 1.11 4.47
C-06 9.61 0.30 20.00 6.96 1.25 25.08
C-07 0.22 0.90 10.00 9.24 1.11 1.99
C-08 7.16 0.30 20.00 6.96 1.25 18.68
C-09 0.43 0.90 10.00 9.24 1.11 3.99
C-10 2.82 0.30 15.00 7.91 1.25 8.37
C-11 0.46 0.79 10.00 9.24 1.25 4.20
C-12 1.13 0.74 10.00 9.24 1.25 9.67
C-13 0.19 0.70 10.00 9.24 1.25 1.53
C-14 0.15 0.90 10.00 9.24 1.11 1.36
C-15 1.29 0.90 10.00 9.24 1.11 11.89
C-16 0.48 0.90 10.00 9.24 1.11 4.43
C-17 1.17 0.90 10.00 9.24 1.11 10.79
C-18 0.25 0.90 10.00 9.24 1.11 2.32
E-01 0.27 0.90 10.00 9.24 1.11 2.49
F-01 12.99 0.70 15.00 7.91 1.25 89.95
G-01 0.66 0.90 10.00 9.24 1.11 6.08
G-02 0.34 0.90 10.00 9.24 1.11 3.15
G-03 1.92 0.50 15.00 7.91 1.25 9.49
G-04 0.53 0.90 10.00 9.24 1.11 4.93
G-05 6.06 0.50 15.00 7.91 1.25 29.97
G-06 2.75 0.50 15.00 7.91 1.25 13.60
H-01 5.23 0.50 15.00 7.91 1.25 25.88
H-02 0.31 0.90 10.00 9.24 1.11 2.86
H-03 0.27 0.90 10.00 9.24 1.11 2.49
H-04 0.70 0.50 15.00 7.91 1.25 3.46
H-05 1.59 0.50 15.00 7.91 1.25 7.86
H-06 0.66 0.50 15.00 7.91 1.25 3.25
H-07 0.29 0.90 10.00 9.24 1.11 2.71
H-08 0.43 0.90 10.00 9.24 1.11 3.93
H-09 1.23 0.50 15.00 7.91 1.25 6.10
H-10 0.78 0.80 10.00 9.24 1.25 7.23
H-11 2.02 0.80 10.00 9.24 1.25 18.69
H-12 0.21 0.90 10.00 9.24 1.11 1.93
I-01 63.65 0.74 20.00 6.96 1.25 355.00
I-02 0.70 0.90 10.00 9.24 1.11 6.50
J-00 0.28 0.90 10.00 9.24 1.11 2.56
J-01 0.90 0.59 10.00 9.24 1.25 6.10
J-02 0.68 0.90 10.00 9.24 1.11 6.32
J-03 0.83 0.48 10.00 9.24 1.25 4.54
J-04 0.86 0.48 10.00 9.24 1.25 4.74
J-05 0.82 0.49 10.00 9.24 1.25 4.58
J-06 0.23 0.90 10.00 9.24 1.11 2.10
K-01 0.45 0.90 10.00 9.24 1.11 4.17
K-02 0.42 0.90 10.00 9.24 1.11 3.86
K-03 0.47 0.90 10.00 9.24 1.11 4.31
K-04 0.36 0.90 10.00 9.24 1.11 3.31
K-05 0.32 0.90 10.00 9.24 1.11 2.91
K-06 0.13 0.90 10.00 9.24 1.11 1.18
L-01 78.86 0.50 20.00 6.96 1.25 350.10
M-01 0.46 0.90 10.00 9.24 1.11 4.27
M-02 0.44 0.90 10.00 9.24 1.11 4.06
M-03 0.67 0.90 10.00 9.24 1.11 6.15
M-04 0.34 0.90 10.00 9.24 1.11 3.13
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDC01.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDC01.dgn1:404:41:57 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837NTS
E. OF LOOP 288 TO W. OF GRISSOM ROAD
DRAINAGE CALCULATIONS
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
197
McKINNEY STREET INLET CAPACITY CALCULATIONS
Inlet Drainage Areas % of Flow from:
Sag Inlet
100-year Runoff
Sag Inlet Split "LStreet Long. Slope "S "0Flow "y
100-year Depth of
Flow "T"
100-year Spread of Inlet Calculation
No.
Inlet Station Side Area No.Area
"C"
Coefficient
Runoff
Weighted
Concentration
Time of
Intensity
100-year
Factor
Frequency
Runoff
100-year
Flow
Carryover
100-year
Gutter Q
Total
100-year
Station
Lower
Station
Higher
Station
Lower
Station
Higher
Station
Lower
Station
Higher Street Section
"xSlope "S
Cross
Roadway
"n"
Manning's
Station
Lower
Station
Higher
Station
Lower
Station
Higher
"wSlope "S
Gutter Cross
Gutter "W"
Depressed
Width of
"0Flow "E
Ratio of
100-year
Depth "a"
Depression
Gutter
"
eCross Slope "S
Equivalent
"T"L
Required Length
100-Year
"L"
Provided
Length
Inlet Type Efficiency "E"
Inlet
"iFlow "Q
Captured
100-Year
flow "q"
Carryover
100-Year
Inlet
Target Comments
(Acres)"C"(min)(in/hr)"Cf"(cfs)(cfs)(cfs)%%(cfs)(cfs)%%(type)(%)(ft)(ft)(ft)(ft)(%)(ft)(%)(ft)(%)(ft)(ft)(%)(cfs)(cfs)
A-01 90+45 LT A-01 0.75 0.90 10.00 9.24 1.11 6.91 0.00 6.91 57%43%3.94 2.97 0.50%0.50%4 Lanes w/TWLTL 2.76%0.017 0.32 0.28 11.45 10.30 22.92%2.00 62.76%0.458 17.14%9.355 10.00 Ex. TxDOT Type 1 Sag 100.00%6.91 0.00 N/A
A-02 93+90 LT A-02/A-03 4.69 0.70 10.00 9.24 1.25 27.24 0.00 27.24 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Drop Inlet N/A 27.24 0.00 N/A
A-04 94+50 LT A-04 0.39 0.90 10.00 9.24 1.11 3.64 0.00 3.64 23%77%0.84 2.80 0.50%0.50%4 Lanes w/TWLTL 2.00%0.017 0.16 0.25 7.83 12.32 22.92%2.00 85.88%0.458 21.68%6.072 10.00 Recessed Sag 100.00%3.64 0.00 N/A
A-05 97+40 LT A-05 0.05 0.90 10.00 9.24 1.11 0.48 0.00 0.48 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Drop Inlet N/A 0.48 0.00 N/A
B-01 91+25 RT B-01 0.63 0.90 10.00 9.24 1.11 5.84 0.00 5.84 40%60%2.33 3.50 0.50%0.50%4 Lanes w/TWLTL 2.90%0.017 0.26 0.31 9.13 10.63 22.92%2.00 73.26%0.458 19.69%7.849 10.00 Recessed Sag 100.00%5.84 0.00 N/A
B-02 94+50 RT B-02 0.47 0.90 10.00 9.24 1.11 4.36 0.00 4.36 22%78%0.96 3.40 0.50%0.50%4 Lanes w/TWLTL 2.00%0.017 0.17 0.27 8.25 13.26 22.92%2.00 83.99%0.458 21.25%6.636 10.00 Recessed Sag 100.00%4.36 0.00 N/A
C-02 100+50 LT C-02 0.52 0.90 10.00 9.24 1.11 4.81 0.00 4.81 N/A N/A N/A N/A 0.76%N/A 4 Lanes w/TWLTL 2.00%0.017 0.28 N/A 13.96 N/A 22.90%2.00 58.89%0.458 15.49%9.475 10.00 Recessed On-Grade 100.00%4.81 0.00 N/A
C-03 100+50 RT C-03 0.38 0.90 10.00 9.24 1.11 3.51 0.00 3.51 N/A N/A N/A N/A 0.76%N/A 4 Lanes w/TWLTL 2.00%0.017 0.25 N/A 12.40 N/A 22.90%2.00 65.09%0.458 16.91%7.876 10.00 Recessed On-Grade 100.00%3.51 0.00 N/A
C-04 103+00 LT C-04 0.22 0.90 10.00 9.24 1.11 2.00 0.00 2.00 N/A N/A N/A N/A 0.76%N/A 4 Lanes w/TWLTL 2.00%0.017 0.20 N/A 10.05 N/A 22.90%2.00 75.57%0.458 19.31%5.747 10.00 Recessed On-Grade 100.00%2.00 0.00 N/A
C-05 105+00 RT C-05 0.48 0.90 10.00 9.24 1.11 4.47 0.00 4.47 N/A N/A N/A N/A 0.90%N/A 4 Lanes w/TWLTL 2.00%0.017 0.26 N/A 13.15 N/A 22.90%2.00 62.01%0.458 16.20%9.408 10.00 Recessed On-Grade 100.00%4.47 0.00 N/A
C-06 105+50 LT C-06 9.61 0.30 20.00 6.96 1.25 25.08 0.00 25.08 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Drop Inlet 100.00%25.08 0.00 N/A
C-07 105+50 LT C-07 0.22 0.90 10.00 9.24 1.11 1.99 0.00 1.99 N/A N/A N/A N/A 0.52%N/A 4 Lanes w/TWLTL 0.67%0.017 0.14 N/A 21.34 N/A 22.90%2.00 61.93%0.458 14.85%5.991 10.00 Recessed On-Grade 100.00%1.99 0.00 N/A
C-08 107+30 LT C-08 7.16 0.30 20.00 6.96 1.25 18.68 0.00 18.68 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Drop Inlet 100.00%18.68 0.00 N/A
C-09 106+65 RT C-09 0.43 0.90 10.00 9.24 1.11 3.99 0.00 3.99 N/A N/A N/A N/A 0.90%N/A 4 Lanes w/TWLTL 2.00%0.017 0.25 N/A 12.60 N/A 22.90%2.00 64.25%0.458 16.71%8.802 10.00 Recessed On-Grade 100.00%3.99 0.00 N/A
C-10 108+35 LT C-10 2.82 0.30 15.00 7.91 1.25 8.37 0.00 8.37 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Drop Inlet 100.00%8.37 0.00 N/A
C-11 107+65 RT C-11 0.46 0.79 10.00 9.24 1.25 4.20 0.00 4.20 N/A N/A N/A N/A 0.50%N/A 4 Lanes w/TWLTL 2.00%0.017 0.29 N/A 14.35 N/A 22.90%2.00 57.43%0.458 15.15%8.000 10.00 Recessed On-Grade 100.00%4.20 0.00 N/A
C-12 108+80 RT C-12 1.13 0.74 10.00 9.24 1.25 9.67 0.00 9.67 N/A N/A N/A N/A 0.50%N/A 4 Lanes w/TWLTL 2.00%0.017 0.39 N/A 19.62 N/A 22.90%2.00 41.85%0.458 11.58%13.341 20.00 Recessed On-Grade 100.00%9.67 0.00 N/A
C-13 109+20 LT C-13 0.19 0.70 10.00 9.24 1.25 1.53 0.00 1.53 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 2-Grate Inlet 100.00%1.53 0.00 N/A
C-14 109+63.80 RT C-14 0.15 0.90 10.00 9.24 1.11 1.36 0.00 1.36 N/A N/A N/A N/A 0.50%N/A 4 Lanes w/TWLTL 2.00%0.017 0.19 N/A 9.41 N/A 22.90%2.00 78.56%0.458 19.99%4.224 5.00 Recessed On-Grade 100.00%1.36 0.00 N/A
C-15 110+15 LT C-15 1.29 0.90 10.00 9.24 1.11 11.89 0.00 11.89 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 6-Grate Inlet 70.00%8.32 3.57 C-16
C-16 110+30 RT C-16 0.48 0.90 10.00 9.24 1.11 4.43 3.57 8.00 48%52%3.84 4.16 0.50%N/A 4 Lanes w/TWLTL 2.00%0.017 0.28 0.29 13.87 14.30 22.90%2.00 59.21%0.458 15.56%14.638 15.00 Recessed Sag 100.00%8.00 0.00 N/A
C-17 110+75 LT C-17 1.17 0.90 10.00 9.24 1.11 10.79 0.00 10.79 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 6-Grate Inlet 100.00%10.79 0.00 N/A
C-18 111+25 RT C-18 0.25 0.90 10.00 9.24 1.11 2.32 0.00 2.32 N/A N/A N/A N/A N/A 1.00%4 Lanes w/TWLTL 2.00%0.017 NA 0.20 N/A 10.08 22.90%2.00 75.44%0.458 19.28%6.638 10.00 Recessed On-Grade 100.00%2.32 0.00 N/A
E-01 114+00 RT E-01 0.27 0.90 10.00 9.24 1.11 2.49 0.00 2.49 N/A N/A N/A N/A N/A 0.63%4 Lanes w/TWLTL 2.00%0.017 N/A 0.23 N/A 11.29 22.90%2.00 69.92%0.458 18.01%6.201 10.00 Recessed On-Grade 100.00%2.49 0.00 N/A
G-01 117+30 RT G-01 0.66 0.90 10.00 9.24 1.11 6.08 0.00 6.08 60%40%3.65 2.43 0.50%0.50%4 Lanes w/TWLTL 2.00%0.017 0.27 0.23 13.61 11.69 22.90%2.00 60.22%0.458 15.79%10.667 15.00 Recessed Sag 100.00%6.08 0.00 N/A
G-02 117+35 LT G-02 0.34 0.90 10.00 9.24 1.11 3.15 0.00 3.15 19%81%0.60 2.55 0.50%0.50%4 Lanes w/TWLTL 0.54%0.017 0.08 0.15 15.66 26.97 22.90%2.00 54.66%0.458 13.06%7.747 10.00 Recessed Sag 100.00%3.15 0.00 N/A
G-03 119+85 LT G-03 1.92 0.50 15.00 7.91 1.25 9.49 0.00 9.49 N/A N/A N/A N/A N/A 0.80%4 Lanes w/TWLTL 2.00%0.017 N/A 0.36 N/A 17.84 22.90%2.00 46.34%0.458 12.61%14.483 20.00 Recessed On-Grade 100.00%9.49 0.00 N/A
G-04 119+85 RT G-04 0.53 0.90 10.00 9.24 1.11 4.93 0.00 4.93 N/A N/A N/A N/A N/A 0.80%4 Lanes w/TWLTL 2.00%0.017 N/A 0.28 N/A 13.95 22.90%2.00 58.91%0.458 15.49%9.723 10.00 Recessed On-Grade 100.00%4.93 0.00 N/A
G-05 122+95 LT G-05 6.06 0.50 15.00 7.91 1.25 29.97 0.00 29.97 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Drop Inlet 100.00%29.97 0.00 N/A
G-06 121+40 LT G-06 2.75 0.50 15.00 7.91 1.25 13.60 0.00 13.60 N/A N/A N/A N/A 0.80%N/A 4 Lanes w/TWLTL 2.00%0.017 0.41 N/A 20.41 N/A 22.90%2.00 40.05%0.458 11.17%18.113 20.00 Recessed On-Grade 100.00%13.60 0.00 N/A
H-01 127+50 LT H-01 5.23 0.50 15.00 7.91 1.25 25.88 0.00 25.88 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Drop Inlet 100.00%25.88 0.00 N/A
H-02 126+70.37 LT H-02 0.31 0.90 10.00 9.24 1.11 2.86 0.00 2.86 81%19%2.32 0.53 0.50%0.50%4 Lanes w/TWLTL 2.00%0.017 0.23 0.13 11.49 6.61 22.90%2.00 69.00%0.458 17.80%5.035 10.00 Recessed Sag 100.00%2.86 0.00 N/A
H-03 126+54.63 RT H-03 0.27 0.90 10.00 9.24 1.11 2.49 0.00 2.49 77%23%1.91 0.58 0.50%0.50%4 Lanes w/TWLTL 2.00%0.017 0.21 0.14 10.67 6.83 22.90%2.00 72.70%0.458 18.65%4.808 10.00 Recessed On-Grade 100.00%2.49 0.00 N/A
H-04 128+65 LT H-04 0.70 0.50 15.00 7.91 1.25 3.46 0.00 3.46 N/A N/A N/A N/A 0.50%N/A 4 Lanes w/TWLTL 2.00%0.017 0.27 N/A 13.34 N/A 22.90%2.00 61.26%0.458 16.03%7.129 10.00 Recessed On-Grade 100.00%3.46 0.00 H-06
H-05 128+50 LT H-05 1.59 0.50 15.00 7.91 1.25 7.86 0.00 7.86 N/A N/A N/A N/A 0.50%N/A N/A N/A 0.017 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Drop Inlet 100.00%7.86 0.00 N/A
H-06 129+38.50 LT H-06 0.66 0.50 15.00 7.91 1.25 3.25 0.00 3.25 N/A N/A N/A N/A 0.50%N/A 4 Lanes w/TWLTL 2.00%0.017 0.26 N/A 13.03 N/A 22.90%2.00 62.51%0.458 16.32%6.867 10.00 Recessed On-Grade 100.00%3.25 0.00 H-07
H-07 130+50 LT H-07 0.29 0.90 10.00 9.24 1.11 2.71 0.00 2.71 N/A N/A N/A N/A 0.50%N/A 4 Lanes w/TWLTL 2.00%0.017 0.24 N/A 12.18 N/A 22.90%2.00 66.05%0.458 17.13%6.183 10.00 Recessed On-Grade 100.00%2.71 0.00 N/A
H-08 130+50 RT H-08 0.43 0.90 10.00 9.24 1.11 3.93 0.00 3.93 N/A N/A N/A N/A 0.50%N/A 4 Lanes w/TWLTL 2.00%0.017 0.28 N/A 13.99 N/A 22.90%2.00 58.76%0.458 15.46%7.684 10.00 Recessed On-Grade 100.00%3.93 0.00 N/A
H-09 130+70 LT H-09 1.23 0.50 15.00 7.91 1.25 6.10 0.00 6.10 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Drop Inlet 100.00%6.10 0.00 N/A
H-10 131+08.57 LT H-10 0.78 0.80 10.00 9.24 1.25 7.23 0.00 7.23 N/A N/A N/A N/A 0.93%N/A 4 Lanes w/TWLTL 2.00%0.017 0.31 N/A 15.66 N/A 22.90%2.00 52.90%0.458 14.11%12.629 15.00 Standard On-Grade 100.00%7.23 0.00 N/A
H-11 131+78.75 LT H-11 2.02 0.80 10.00 9.24 1.25 18.69 0.00 18.69 N/A N/A N/A N/A 0.50%N/A 4 Lanes w/TWLTL 2.00%0.017 0.50 N/A 25.12 N/A 22.90%2.00 31.58%0.458 9.23%20.158 25.00 Standard On-Grade 100.00%18.69 0.00 N/A
H-12 132+05 RT H-12 0.21 0.90 10.00 9.24 1.11 1.93 0.00 1.93 N/A N/A N/A N/A 0.50%N/A 4 Lanes w/TWLTL 2.00%0.017 0.21 N/A 10.73 N/A 22.90%2.00 72.45%0.458 18.59%5.108 10.00 Recessed On-Grade 100.00%1.93 0.00 N/A
I-02 133+35 LT I-02 0.70 0.90 10.00 9.24 1.11 6.50 0.45 6.94 66%34%4.58 2.36 0.50%0.50%4 Lanes w/TWLTL 2.00%0.017 0.30 0.23 14.83 11.56 22.90%2.00 55.72%0.458 14.76%10.732 15.00 Recessed Sag 100.00%6.94 0.00 N/A
J-00 132+15 RT J-00 0.28 0.90 10.00 9.24 1.11 2.56 0.52 3.08 57%43%1.75 1.32 0.50%0.50%4 Lanes w/TWLTL 2.00%0.017 0.21 0.19 10.34 9.30 22.90%2.00 74.23%0.458 19.00%7.301 10.00 Recessed Sag 100.00%3.08 0.00 N/A
J-01 135+00 LT J-01 0.90 0.59 10.00 9.24 1.25 6.10 0.00 6.10 N/A N/A N/A N/A N/A 1.76%4 Lanes w/TWLTL 2.00%0.017 N/A 0.26 N/A 13.04 22.90%2.00 62.49%0.458 16.31%13.058 10.00 Recessed On-Grade 92.67%5.65 0.45 I-02
J-02 134+50 RT J-02 0.68 0.90 10.00 9.24 1.11 6.32 0.00 6.32 N/A N/A N/A N/A N/A 1.76%4 Lanes w/TWLTL 2.00%0.017 N/A 0.26 N/A 13.21 22.90%2.00 61.80%0.458 16.15%13.329 10.00 Recessed On-Grade 91.77%5.80 0.52 J-00
J-03 137+00 LT J-03 0.83 0.48 10.00 9.24 1.25 4.54 0.00 4.54 N/A N/A N/A N/A N/A 0.76%4 Lanes w/TWLTL 2.00%0.017 N/A 0.27 N/A 13.66 22.90%2.00 60.02%0.458 15.74%9.159 10.00 Recessed On-Grade 100.00%4.54 0.00 N/A
J-04 139+10 LT J-04 0.86 0.48 10.00 9.24 1.25 4.74 0.00 4.74 N/A N/A N/A N/A N/A 0.76%4 Lanes w/TWLTL 2.00%0.017 N/A 0.28 N/A 13.88 22.90%2.00 59.19%0.458 15.55%9.391 10.00 Recessed On-Grade 100.00%4.74 0.00 N/A
J-05 141+15 LT J-05 0.82 0.49 10.00 9.24 1.25 4.58 0.00 4.58 N/A N/A N/A N/A N/A 0.76%4 Lanes w/TWLTL 2.00%0.017 N/A 0.27 N/A 13.71 22.90%2.00 59.85%0.458 15.70%9.207 10.00 Recessed On-Grade 100.00%4.58 0.00 N/A
J-06 139+00 RT J-06 0.23 0.90 10.00 9.24 1.11 2.10 0.00 2.10 N/A N/A N/A N/A N/A 0.76%4 Lanes w/TWLTL 2.00%0.017 N/A 0.20 N/A 10.24 22.90%2.00 74.72%0.458 19.11%5.902 10.00 Recessed On-Grade 100.00%2.10 0.00 N/A
K-01 145+50 LT K-01 0.45 0.90 10.00 9.24 1.11 4.17 0.00 4.17 N/A N/A N/A N/A 2.56%N/A 4 Lanes w/TWLTL 2.00%0.017 0.21 N/A 10.54 N/A 22.90%2.00 73.32%0.458 18.79%11.441 10.00 Recessed On-Grade 97.60%4.07 0.10 K-03
K-02 146+20 RT K-02 0.42 0.90 10.00 9.24 1.11 3.86 0.00 3.86 N/A N/A N/A N/A 0.71%N/A 4 Lanes w/TWLTL 2.00%0.017 0.26 N/A 13.02 N/A 22.90%2.00 62.55%0.458 16.32%8.203 10.00 Recessed On-Grade 100.00%3.86 0.00 N/A
K-03 148+70 LT K-03 0.47 0.90 10.00 9.24 1.11 4.31 0.10 4.41 N/A N/A N/A N/A 0.71%N/A 4 Lanes w/TWLTL 2.00%0.017 0.27 N/A 13.69 N/A 22.90%2.00 59.91%0.458 15.72%8.877 10.00 Recessed On-Grade 100.00%4.41 0.00 N/A
K-04 149+50 RT K-04 0.36 0.90 10.00 9.24 1.11 3.31 0.00 3.31 N/A N/A N/A N/A 0.71%N/A 4 Lanes w/TWLTL 2.00%0.017 0.25 N/A 12.29 N/A 22.90%2.00 65.57%0.458 17.02%7.499 10.00 Recessed On-Grade 100.00%3.31 0.00 N/A
K-05 149+98.96 LT K-05 0.32 0.90 10.00 9.24 1.11 2.91 0.00 2.91 73%27%2.13 0.79 0.50%0.50%2 Lanes Divided 2.00%0.017 0.26 0.15 13.00 7.66 22.90%2.00 62.63%0.458 16.34%3.728 10.00 Standard Sag 100.00%2.91 0.00 N/A
K-06 150+47.92 LT K-06 0.13 0.90 10.00 9.24 1.11 1.18 0.00 1.18 41%59%0.48 0.70 0.50%0.50%2 Lanes Divided 2.00%0.017 0.13 0.15 6.38 7.31 22.90%2.00 91.97%0.458 23.06%3.427 10.00 Standard Sag 100.00%1.18 0.00 N/A
M-01 152+70 RT M-01 0.46 0.90 10.00 9.24 1.11 4.27 0.00 4.27 72%28%3.07 1.20 0.50%0.50%4 Lanes w/TWLTL 2.00%0.017 0.26 0.18 12.76 8.96 22.90%2.00 63.59%0.458 16.56%7.431 10.00 Recessed Sag 100.00%4.27 0.00 N/A
M-02 152+70 LT M-02 0.44 0.90 10.00 9.24 1.11 4.06 0.04 4.10 57%43%2.34 1.76 0.50%0.50%4 Lanes w/TWLTL 2.00%0.017 0.23 0.21 11.52 10.37 22.90%2.00 68.89%0.458 17.78%8.763 10.00 Recessed Sag 100.00%4.10 0.00 N/A
M-03 154+30 LT M-03 0.67 0.90 10.00 9.24 1.11 6.15 0.26 6.41 N/A N/A N/A N/A N/A 0.57%4 Lanes w/TWLTL 2.00%0.017 N/A 0.33 N/A 16.41 22.90%2.00 50.51%0.458 13.57%10.618 10.00 Recessed On-Grade 99.40%6.37 0.04 M-02
M-04 154+00 RT M-04 0.34 0.90 10.00 9.24 1.11 3.13 0.00 3.13 N/A N/A N/A N/A N/A 0.57%4 Lanes w/TWLTL 2.00%0.017 N/A 0.25 N/A 12.55 22.90%2.00 64.49%0.458 16.77%6.924 10.00 Recessed On-Grade 100.00%3.13 0.00 N/A
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDC02.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDC02.dgn1:404:41:59 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837NTS
E. OF LOOP 288 TO W. OF GRISSOM ROAD
DRAINAGE CALCULATIONS
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
198
McKINNEY STREET STORM DRAIN CALCULATIONS
From To Pipe Drainage Area Runoff "c"Frequency Factor Inc. c*Cf*A Total c*Cf*A Time of Concentration 100-yr.100-yr.Inlet Inlet "Q" Actual "Q" Pipe Pipe Size Box Size n Sf Spipe HGL Head Loss Calculations Design HGL Invert Elevation T/C or Comments
Length Incremental Total Area Cf Inlet Travel Total Intensity Runoff Carryover Carryover Capacity Diameter Width Height Ground Elev
Area No.Area (To Inlet)"Q" (From Inlet)U/S D/S V1 (in)V2 (out)/2g 2V1 /2g2V2 jK /2g2V1jK Head Loss From To
(Sta.)(Sta.)(Ft)(Acres)(Acres)(Min.)(Min.)(Min.)(in/hr)(cfs)(cfs)(cfs)(cfs)(cfs)(in)(ft)(ft)(ft/ft)(ft/ft)(ft)(ft)(ft/s)(ft/s)(ft)(ft) (ft) (ft) (ft) (ft) (ft) (ft)
LINE A
900.25 960.36 60.11 A-03 N/A N/A N/A N/A N/A N/A 10.00 0.00 10.00 9.24 7.84 0.00 0.00 7.84 33.47 24.00 N/A N/A 0.013 0.00121 0.0219 587.55 587.48 0.00 2.50 0.00 0.10 1.25 0.00 0.12 587.67 584.42 585.74 590.74
646.17 900.25 254.08 MH N/A N/A N/A N/A N/A N/A 10.00 0.00 10.00 9.24 7.84 0.00 0.00 7.84 10.11 24.00 N/A N/A 0.013 0.00121 0.0020 587.38 587.07 2.50 2.50 0.10 0.10 0.50 0.05 0.10 587.48 583.92 584.42 589.71
578.31 646.17 67.86 A-04 0.39 0.39 0.90 1.11 0.39 0.39 10.00 0.00 10.00 9.24 11.48 0.00 0.00 11.48 10.11 24.00 N/A N/A 0.013 0.00259 0.0020 586.94 586.76 2.50 3.65 0.10 0.21 0.75 0.07 0.13 587.07 583.78 583.92 588.99
490.69 578.31 87.62 A-02, MH 2.40 2.79 0.70 1.25 2.10 2.49 10.00 2.41 12.41 8.54 29.13 0.00 0.00 29.13 31.21 N/A 4.00 2.00 0.013 0.00174 0.0020 586.66 586.51 3.65 3.64 0.21 0.21 0.50 0.10 0.10 586.76 583.61 583.78 588.43
374.34 490.69 116.35 BEND N/A 2.79 N/A N/A N/A 2.49 10.00 2.41 12.41 8.54 29.13 0.00 0.00 29.13 31.21 N/A 4.00 2.00 0.013 0.00174 0.0020 586.41 586.20 3.64 3.64 0.21 0.21 0.20 0.04 0.10 586.51 583.37 583.61 588.84
312.34 374.34 62.00 BEND N/A 2.79 N/A N/A N/A 2.49 10.00 2.41 12.41 8.54 29.13 0.00 0.00 29.13 31.21 N/A 4.00 2.00 0.013 0.00174 0.0020 586.10 586.00 3.64 3.64 0.21 0.21 0.20 0.04 0.10 586.20 583.25 583.37 588.04
258.57 312.34 53.77 BEND N/A 2.79 N/A N/A N/A 2.49 10.00 2.41 12.41 8.54 29.13 0.00 0.00 29.13 31.21 N/A 4.00 2.00 0.013 0.00174 0.0020 585.90 585.80 3.64 3.64 0.21 0.21 0.20 0.04 0.10 586.00 583.14 583.25 587.78
241.60 258.57 16.97 BEND N/A 2.79 N/A N/A N/A 2.49 10.00 2.41 12.41 8.54 29.13 0.00 0.00 29.13 31.21 N/A 4.00 2.00 0.013 0.00174 0.0020 585.70 585.67 3.64 3.64 0.21 0.21 0.20 0.04 0.10 585.80 583.11 583.14 587.98
230.00 241.60 11.60 A-01 0.75 3.54 0.90 1.11 0.75 3.24 10.00 3.95 13.95 8.15 34.27 0.00 0.00 34.27 31.21 N/A 4.00 2.00 0.013 0.00241 0.0020 585.54 585.51 3.64 4.28 0.21 0.28 0.75 0.15 0.13 585.67 583.08 583.11 587.85
147.91 230.00 82.09 PVI N/A 3.54 N/A N/A N/A 3.24 10.00 3.95 13.95 8.15 34.27 0.00 0.00 34.27 133.14 N/A 4.00 2.00 0.013 0.00241 0.0364 585.41 585.22 4.28 4.28 0.28 0.28 0.30 0.09 0.10 585.51 580.10 583.08 587.98
100.00 147.91 47.91 BEND N/A 3.54 N/A N/A N/A 3.24 10.00 3.95 13.95 8.15 34.27 0.00 0.00 34.27 31.21 N/A 4.00 2.00 0.013 0.00241 0.0020 585.12 585.00 4.28 4.28 0.28 0.28 0.28 0.08 0.10 585.22 580.00 580.10 587.97
LAT A-02
100.00 129.50 29.50 A-02 2.40 2.40 0.70 1.25 2.10 2.10 10.00 0.00 10.00 9.24 19.40 0.00 0.00 19.40 29.28 30.00 N/A N/A 0.013 0.00224 0.0051 586.83 586.76 0.00 3.95 0.00 0.24 1.25 0.00 0.30 587.13 583.78 583.93 588.43
LAT A-04
100.00 111.30 11.30 A-04 0.39 0.39 0.90 1.11 0.39 0.39 10.00 0.00 10.00 9.24 3.64 0.00 0.00 3.64 17.66 18.00 N/A N/A 0.013 0.00121 0.0283 587.08 587.07 0.00 2.06 0.00 0.07 1.25 0.00 0.10 587.18 584.17 584.49 588.99
LINE B
555.94 566.95 11.01 B-02 0.47 0.47 0.90 1.11 0.47 0.47 10.00 0.00 10.00 9.24 4.36 0.00 0.00 4.36 4.86 18.00 N/A N/A 0.013 0.00174 0.0021 588.24 588.22 0.00 2.47 0.00 0.09 1.25 0.00 0.12 588.36 584.97 584.99 588.99
240.45 555.94 315.49 MH N/A 0.47 N/A N/A N/A 0.47 10.00 0.00 10.00 9.24 4.36 0.00 0.00 4.36 4.86 18.00 N/A N/A 0.013 0.00174 0.0021 588.12 587.58 2.47 2.47 0.09 0.09 0.50 0.05 0.10 588.22 584.29 584.97 588.61
211.89 240.45 28.56 B-01 0.63 1.10 0.90 1.11 0.63 1.10 10.00 2.20 12.20 8.59 9.49 0.00 0.00 9.49 10.43 24.00 N/A N/A 0.013 0.00177 0.0021 587.48 587.43 2.47 3.02 0.09 0.14 0.75 0.07 0.10 587.58 584.23 584.29 588.36
196.29 211.89 15.60 BEND N/A 1.10 N/A N/A N/A 1.10 10.00 2.20 12.20 8.59 9.49 0.00 0.00 9.49 10.43 24.00 N/A N/A 0.013 0.00177 0.0021 587.33 587.30 3.02 3.02 0.14 0.14 0.35 0.05 0.10 587.43 584.20 584.23 588.02
125.72 196.29 70.57 BEND N/A 1.10 N/A N/A N/A 1.10 10.00 2.20 12.20 8.59 9.49 0.00 0.00 9.49 13.11 24.00 N/A N/A 0.013 0.00177 0.0034 587.20 587.07 3.02 3.02 0.14 0.14 0.35 0.05 0.10 587.30 583.96 584.20 587.97
100.87 125.72 24.85 BEND N/A 1.10 N/A N/A N/A 1.10 10.00 2.20 12.20 8.59 9.49 0.00 0.00 9.49 13.11 24.00 N/A N/A 0.013 0.00177 0.0034 586.97 586.93 3.02 3.02 0.14 0.14 0.28 0.04 0.10 587.07 583.88 583.96 588.56
LAT B-01
100.00 106.29 6.29 B-01 0.63 0.63 0.90 1.11 0.63 0.63 10.00 0.00 10.00 9.24 5.84 0.00 0.00 5.84 11.83 18.00 N/A N/A 0.013 0.00311 0.0127 587.60 587.58 0.00 3.30 0.00 0.17 1.25 0.00 0.21 587.81 584.28 584.36 588.36
LINE C
1297.80 1309.12 11.32 C-03 0.38 0.38 0.90 1.11 0.38 0.38 10.00 0.00 10.00 9.24 3.51 0.00 0.00 3.51 13.27 18.00 N/A N/A 0.013 0.00112 0.0160 585.05 585.04 0.00 1.99 0.00 0.06 1.25 0.00 0.10 585.15 584.03 584.21 588.71
1251.99 1297.80 45.81 MH N/A 0.38 N/A N/A N/A 0.38 10.00 0.00 10.00 9.24 3.51 0.00 0.00 3.51 13.27 18.00 N/A N/A 0.013 0.00112 0.0160 584.94 584.89 1.99 1.99 0.06 0.06 0.50 0.03 0.10 585.04 583.30 584.03 588.27
1005.63 1251.99 246.36 C-02 0.52 0.90 0.90 1.11 0.52 0.90 10.00 0.48 10.48 9.09 8.18 0.00 0.00 8.18 13.27 18.00 N/A N/A 0.013 0.00611 0.0160 584.60 583.10 1.99 4.63 0.06 0.33 0.75 0.05 0.29 584.89 579.37 583.30 588.71
846.06 1005.63 159.57 C-04 0.22 1.12 0.90 1.11 0.22 1.12 10.00 1.37 11.37 8.83 9.86 0.00 0.00 9.86 20.60 24.00 N/A N/A 0.013 0.00191 0.0083 583.00 582.69 4.63 3.14 0.33 0.15 0.75 0.25 0.10 583.10 577.54 578.87 586.80
763.23 846.06 82.83 C-05 0.48 1.60 0.90 1.11 0.48 1.60 10.00 2.21 12.21 8.59 13.76 0.00 0.00 13.76 20.60 24.00 N/A N/A 0.013 0.00371 0.0083 582.51 582.20 3.14 4.38 0.15 0.30 0.75 0.11 0.18 582.69 576.86 577.54 585.20
678.57 763.23 84.66 C-01, C-06, C-07, MH 9.83 11.43 0.31 1.25 3.84 5.44 20.00 2.53 22.53 6.57 40.16 0.00 0.00 40.16 29.82 36.00 N/A N/A 0.013 0.00363 0.0020 581.85 581.54 4.38 5.68 0.30 0.50 0.50 0.15 0.35 582.20 575.69 575.86 584.00
577.02 678.57 101.55 C-09 0.43 11.86 0.90 1.11 0.43 5.87 20.00 2.78 22.78 6.53 42.78 0.00 0.00 42.78 29.82 36.00 N/A N/A 0.013 0.00412 0.0020 581.35 580.93 5.68 6.05 0.50 0.57 0.75 0.38 0.19 581.54 575.48 575.69 583.72
555.75 577.02 21.27 C-11 0.46 12.32 0.79 1.25 0.45 6.33 20.00 3.06 23.06 6.49 45.51 0.00 0.00 45.51 29.82 36.00 N/A N/A 0.013 0.00466 0.0020 580.71 580.61 6.05 6.44 0.57 0.64 0.75 0.43 0.22 580.93 575.44 575.48 582.87
461.72 555.75 94.03 C-08, MH 7.16 19.48 0.30 1.25 2.69 9.01 20.00 3.11 23.11 6.49 62.87 0.00 0.00 62.87 81.79 N/A 4.00 4.00 0.013 0.00118 0.0020 580.51 580.40 6.44 3.93 0.64 0.24 0.50 0.32 0.10 580.61 574.25 574.44 583.71
449.23 461.72 12.49 C-12 1.13 20.61 0.74 1.25 1.05 10.06 20.00 3.51 23.51 6.43 69.11 0.00 0.00 69.11 81.79 N/A 4.00 4.00 0.013 0.00143 0.0020 580.29 580.27 3.93 4.32 0.24 0.29 0.75 0.18 0.11 580.40 574.23 574.25 582.30
389.58 449.23 59.65 C-10 2.82 23.43 0.30 1.25 1.06 11.12 20.00 3.56 23.56 6.42 75.84 0.00 0.00 75.84 81.79 N/A 4.00 4.00 0.013 0.00172 0.0020 580.14 580.04 4.32 4.74 0.29 0.35 0.75 0.22 0.13 580.27 574.11 574.23 583.28
377.92 389.58 11.66 C-13 0.19 23.62 0.70 1.25 0.17 11.28 20.00 3.77 23.77 6.40 76.58 0.00 0.00 76.58 81.79 N/A 4.00 4.00 0.013 0.00175 0.0020 579.94 579.92 4.74 4.79 0.35 0.36 0.75 0.26 0.10 580.04 574.09 574.11 583.91
311.49 377.92 66.43 C-14 0.15 23.77 0.90 1.11 0.15 11.43 20.00 3.81 23.81 6.39 77.47 0.00 0.00 77.47 81.79 N/A 4.00 4.00 0.013 0.00179 0.0020 579.82 579.70 4.79 4.84 0.36 0.36 0.75 0.27 0.10 579.92 573.95 574.09 581.88
263.32 311.49 48.17 C-16 0.48 24.25 0.90 1.11 0.48 11.91 20.00 4.04 24.04 6.36 80.16 3.57 0.00 83.73 81.79 N/A 4.00 4.00 0.013 0.00210 0.0020 579.55 579.45 4.84 5.23 0.36 0.43 0.75 0.27 0.15 579.70 573.86 573.95 581.67
216.72 263.32 46.60 C-15 1.29 25.54 0.90 1.11 1.29 13.20 20.00 4.19 24.19 6.34 88.08 0.00 3.57 88.08 81.79 N/A 4.00 4.00 0.013 0.00232 0.0020 579.30 579.19 5.23 5.50 0.43 0.47 0.75 0.32 0.15 579.45 573.76 573.86 583.36
205.82 216.72 10.90 C-18 0.25 25.79 0.90 1.11 0.25 13.45 20.00 4.33 24.33 6.32 89.42 0.00 0.00 89.42 81.79 N/A 4.00 4.00 0.013 0.00239 0.0020 579.06 579.03 5.50 5.59 0.47 0.48 0.75 0.35 0.13 579.19 573.74 573.76 582.34
100.00 205.82 105.82 C-17 1.17 26.96 0.90 1.11 1.17 14.61 20.00 4.36 24.36 6.32 96.74 0.00 0.00 96.74 81.79 N/A 4.00 4.00 0.013 0.00280 0.0020 578.83 578.53 5.59 6.05 0.48 0.57 0.75 0.36 0.20 579.03 573.53 573.74 583.93
LAT C-02
100.00 175.34 75.34 C-02 0.52 0.52 0.90 1.11 0.52 0.52 10.00 0.00 10.00 9.24 4.81 0.00 0.00 4.81 11.55 18.00 N/A N/A 0.013 0.00211 0.0121 585.05 584.89 0.00 2.72 0.00 0.11 1.25 0.00 0.14 585.19 583.30 584.21 588.71
LAT C-04
100.00 174.94 74.94 C-04 0.22 0.22 0.90 1.11 0.22 0.22 10.00 0.00 10.00 9.24 2.00 0.00 0.00 2.00 13.30 18.00 N/A N/A 0.013 0.00037 0.0160 583.12 583.10 0.00 1.13 0.00 0.02 1.25 0.00 0.10 583.22 579.09 580.30 586.80
LAT C-05
100.00 111.34 11.34 C-05 0.48 0.48 0.90 1.11 0.48 0.48 10.00 0.00 10.00 9.24 4.47 0.00 0.00 4.47 54.10 18.00 N/A N/A 0.013 0.00182 0.2654 582.71 582.69 0.00 2.53 0.00 0.10 1.25 0.00 0.12 582.84 577.69 580.70 585.20
LAT C-06
159.06 193.13 34.07 C-06 9.61 9.61 0.30 1.25 3.60 3.60 20.00 0.00 20.00 6.96 25.08 0.00 0.00 25.08 132.68 36.00 N/A N/A 0.013 0.00142 0.0396 582.44 582.39 0.00 3.55 0.00 0.20 1.25 0.00 0.24 582.69 578.19 579.54 585.54
100.00 159.06 59.06 C-07 0.22 9.83 0.90 1.11 0.22 3.82 20.00 0.16 20.16 6.93 26.48 0.00 0.00 26.48 132.68 36.00 N/A N/A 0.013 0.00158 0.0396 582.29 582.20 3.55 3.75 0.20 0.22 1.25 0.24 0.10 582.39 575.85 578.19 585.13
LAT C-07
100.00 111.78 11.78 C-07 0.22 0.22 0.90 1.11 0.22 0.22 10.00 0.00 10.00 9.24 1.99 0.00 0.00 1.99 39.78 18.00 N/A N/A 0.013 0.00036 0.1435 582.40 582.39 0.00 1.13 0.00 0.02 1.25 0.00 0.10 582.50 578.94 580.63 585.13
LAT C-08
100.00 192.97 92.97 C-08 7.16 7.16 0.30 1.25 2.69 2.69 20.00 0.00 20.00 6.96 18.68 0.00 0.00 18.68 74.78 30.00 N/A N/A 0.013 0.00208 0.0333 580.81 580.61 0.00 3.81 0.00 0.22 1.25 0.00 0.28 581.09 575.19 578.28 583.71
LAT C-09
100.00 111.29 11.29 C-09 0.43 0.43 0.90 1.11 0.43 0.43 10.00 0.00 10.00 9.24 3.99 0.00 0.00 3.99 52.21 18.00 N/A N/A 0.013 0.00145 0.2472 581.56 581.54 0.00 2.26 0.00 0.08 1.25 0.00 0.10 581.66 576.43 579.22 583.72
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDC03.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDC03.dgn1:404:42:03 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837NTS
E. OF LOOP 288 TO W. OF GRISSOM ROAD
DRAINAGE CALCULATIONS
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
199
McKINNEY STREET STORM DRAIN CALCULATIONS
From To Pipe Drainage Area Runoff "c"Frequency Factor Inc. c*Cf*A Total c*Cf*A Time of Concentration 100-yr.100-yr.Inlet Inlet "Q" Actual "Q" Pipe Pipe Size Box Size n Sf Spipe HGL Head Loss Calculations Design HGL Invert Elevation T/C or Comments
Length Incremental Total Area Cf Inlet Travel Total Intensity Runoff Carryover Carryover Capacity Diameter Width Height Ground Elev
Area No.Area (To Inlet)"Q" (From Inlet)U/S D/S V1 (in)V2 (out)/2g
2
V1 /2g
2
V2 jK /2g
2
V1jK Head Loss From To
(Sta.)(Sta.)(Ft)(Acres)(Acres)(Min.)(Min.)(Min.)(in/hr)(cfs)(cfs)(cfs)(cfs)(cfs)(in)(ft)(ft)(ft/ft)(ft/ft)(ft)(ft)(ft/s)(ft/s)(ft)(ft) (ft) (ft) (ft) (ft) (ft) (ft)
LAT C-10
100.00 192.63 92.63 C-10 2.82 2.82 0.30 1.25 1.06 1.06 15.00 0.00 15.00 7.91 8.37 0.00 0.00 8.37 41.02 24.00 N/A N/A 0.013 0.00138 0.0329 580.40 580.27 0.00 2.66 0.00 0.11 1.25 0.00 0.14 580.54 575.23 578.28 583.28
LAT C-11
100.00 111.29 11.29 C-11 0.46 0.46 0.79 1.25 0.45 0.45 10.00 0.00 10.00 9.24 4.20 0.00 0.00 4.20 45.72 18.00 N/A N/A 0.013 0.00161 0.1896 580.95 580.93 0.00 2.38 0.00 0.09 1.25 0.00 0.11 581.06 576.23 578.37 582.87
LAT C-12
100.00 111.31 11.31 C-12 1.13 1.13 0.74 1.25 1.05 1.05 10.00 0.00 10.00 9.24 9.67 0.00 0.00 9.67 107.39 24.00 N/A N/A 0.013 0.00184 0.2255 580.42 580.40 0.00 3.08 0.00 0.15 1.25 0.00 0.18 580.61 575.25 577.80 582.30
LAT C-13
100.00 180.29 80.29 C-13 0.19 0.19 0.70 1.25 0.17 0.17 10.00 0.00 10.00 9.24 1.53 0.00 0.00 1.53 23.57 18.00 N/A N/A 0.013 0.00021 0.0504 580.06 580.04 0.00 0.87 0.00 0.01 1.25 0.00 0.10 580.16 575.36 579.41 583.91
LAT C-14
100.00 111.31 11.31 C-14 0.15 0.15 0.90 1.11 0.15 0.15 10.00 0.00 10.00 9.24 1.36 0.00 0.00 1.36 44.60 18.00 N/A N/A 0.013 0.00017 0.1804 579.92 579.92 0.00 0.77 0.00 0.01 1.25 0.00 0.10 580.02 575.34 577.38 581.88
LAT C-15
100.00 200.28 100.28 C-15 1.29 1.29 0.90 1.11 1.29 1.29 10.00 0.00 10.00 9.24 11.89 0.00 3.57 8.32 42.25 24.00 N/A N/A 0.013 0.00136 0.0349 579.58 579.45 0.00 2.65 0.00 0.11 1.25 0.00 0.14 579.72 574.86 578.36 583.36
LAT C-16
100.00 111.48 11.48 C-16 0.48 0.48 0.90 1.11 0.48 0.48 10.00 0.00 10.00 9.24 4.43 3.57 0.00 8.00 43.51 18.00 N/A N/A 0.013 0.00583 0.1717 579.77 579.70 0.00 4.53 0.00 0.32 1.25 0.00 0.40 580.17 575.20 577.17 581.67
LAT C-17
100.00 197.45 97.45 C-17 1.17 1.17 0.90 1.11 1.17 1.17 10.00 0.00 10.00 9.24 10.79 0.00 0.00 10.79 49.60 24.00 N/A N/A 0.013 0.00229 0.0481 579.25 579.03 0.00 3.43 0.00 0.18 1.25 0.00 0.23 579.48 574.74 579.43 583.93
LAT C-18
100.00 111.31 11.31 C-18 0.25 0.25 0.90 1.11 0.25 0.25 10.00 0.00 10.00 9.24 2.32 0.00 0.00 2.32 52.52 18.00 N/A N/A 0.013 0.00049 0.2502 579.19 579.19 0.00 1.31 0.00 0.03 1.25 0.00 0.10 579.29 575.01 577.84 582.34
LINE E
220.04 229.94 9.90 E-01 0.27 0.27 0.90 1.11 0.27 0.27 10.00 0.00 10.00 9.24 2.49 0.00 0.00 2.49 10.52 18.00 N/A N/A 0.013 0.00056 0.0100 580.44 580.44 0.00 1.41 0.00 0.03 1.25 0.00 0.10 580.54 579.50 579.60 584.10
100.00 220.04 120.04 MH N/A 0.27 N/A N/A N/A 0.27 10.00 0.00 10.00 9.24 2.49 0.00 0.00 2.49 10.52 18.00 N/A N/A 0.013 0.00056 0.0100 580.34 580.27 1.41 1.41 0.03 0.03 0.50 0.02 0.10 580.44 578.29 579.50 583.75
LINE F
1011.50 1068.00 56.50 F-01 12.99 12.99 0.70 1.25 11.37 11.37 15.00 0.00 15.00 7.91 89.95 0.00 0.00 89.95 173.42 N/A 5.00 4.00 0.013 0.00135 0.0050 580.34 580.27 0.00 4.50 0.00 0.31 0.50 0.00 0.31 580.66 577.05 577.33 585.80
1000.00 1011.50 11.50 LINE E, LINE G 12.53 25.52 N/A N/A 8.51 19.88 17.85 0.21 18.06 7.30 145.01 0.00 0.00 145.01 173.42 N/A 5.00 4.00 0.013 0.00350 0.0050 579.53 579.49 4.50 7.25 0.31 0.82 0.25 0.08 0.74 580.27 576.99 577.05 584.86
LINE G
872.94 952.94 80.00 G-05 6.06 6.06 0.50 1.25 3.79 3.79 15.00 0.00 15.00 7.91 29.97 0.00 0.00 29.97 47.94 36.00 N/A N/A 0.013 0.00202 0.0052 583.76 583.60 0.00 4.24 0.00 0.28 1.25 0.00 0.35 584.11 580.55 580.97 587.47
662.16 872.94 210.78 MH N/A 6.06 N/A N/A N/A 3.79 15.00 0.00 15.00 7.91 29.97 0.00 0.00 29.97 65.68 N/A 5.00 2.00 0.013 0.00108 0.0052 583.50 583.27 4.24 3.00 0.28 0.14 0.25 0.07 0.10 583.60 579.47 580.55 586.68
552.62 662.16 109.54 G-06 2.75 8.81 0.50 1.25 1.72 5.51 15.00 1.49 16.49 7.60 41.83 0.00 0.00 41.83 65.68 N/A 5.00 2.00 0.013 0.00210 0.0052 583.11 582.88 3.00 4.18 0.14 0.27 0.75 0.10 0.17 583.27 578.90 579.47 586.19
507.99 552.62 44.63 G-04 0.53 9.34 0.90 1.11 0.53 6.04 15.00 1.92 16.92 7.51 45.36 0.00 0.00 45.36 65.68 N/A 5.00 2.00 0.013 0.00247 0.0052 582.76 582.65 4.18 4.54 0.27 0.32 0.75 0.20 0.12 582.88 578.67 578.90 584.95
298.20 507.99 209.79 G-03 1.92 11.26 0.50 1.25 1.20 7.24 15.00 2.09 17.09 7.48 54.14 0.00 0.00 54.14 65.68 N/A 5.00 2.00 0.013 0.00351 0.0052 582.43 581.70 4.54 5.41 0.32 0.46 0.75 0.24 0.22 582.65 577.58 578.67 584.95
258.55 298.20 39.65 G-01 0.66 11.92 0.90 1.11 0.66 7.90 15.00 2.73 17.73 7.36 58.09 0.00 0.00 58.09 65.68 N/A 5.00 2.00 0.013 0.00405 0.0052 581.51 581.35 5.41 5.81 0.46 0.52 0.75 0.34 0.18 581.70 577.38 577.58 583.10
250.00 258.55 8.55 G-02, MH 0.34 12.26 0.90 1.11 0.34 8.24 15.00 2.85 17.85 7.33 60.42 0.00 0.00 60.42 65.68 N/A 5.00 2.00 0.013 0.00438 0.0052 581.05 581.01 5.81 6.04 0.52 0.57 0.50 0.26 0.30 581.35 577.33 577.38 582.85
102.93 250.00 147.07 PVI N/A 12.26 N/A N/A N/A 8.24 15.00 2.85 17.85 7.33 60.42 0.00 0.00 60.42 40.85 N/A 5.00 2.00 0.013 0.00438 0.0020 580.91 580.27 6.04 6.04 0.57 0.57 0.35 0.20 0.10 581.01 577.04 577.33 584.46
LAT G-01
100.00 111.30 11.30 G-01 0.66 0.66 0.90 1.11 0.66 0.66 10.00 0.00 10.00 9.24 6.08 0.00 0.00 6.08 27.40 18.00 N/A N/A 0.013 0.00337 0.0681 581.73 581.70 0.00 3.44 0.00 0.18 1.25 0.00 0.23 581.96 577.83 578.60 583.10
LAT G-02
100.00 174.78 74.78 G-02 0.34 0.34 0.90 1.11 0.34 0.34 10.00 0.00 10.00 9.24 3.15 0.00 0.00 3.15 14.36 18.00 N/A N/A 0.013 0.00090 0.0187 581.42 581.35 0.00 1.78 0.00 0.05 1.25 0.00 0.10 581.52 577.63 579.03 583.53
LAT G-03
100.00 174.78 74.78 G-03 1.92 1.92 0.50 1.25 1.20 1.20 15.00 0.00 15.00 7.91 9.49 0.00 0.00 9.49 29.57 24.00 N/A N/A 0.013 0.00177 0.0171 582.78 582.65 0.00 3.02 0.00 0.14 1.25 0.00 0.18 582.96 578.67 579.95 586.19
LAT G-04
100.00 111.32 11.32 G-04 0.53 0.53 0.90 1.11 0.53 0.53 10.00 0.00 10.00 9.24 4.93 0.00 0.00 4.93 35.59 18.00 N/A N/A 0.013 0.00222 0.1149 582.90 582.88 0.00 2.79 0.00 0.12 1.25 0.00 0.15 583.05 579.15 580.45 584.95
LAT G-06
100.00 175.13 75.13 G-06 2.75 2.75 0.50 1.25 1.72 1.72 15.00 0.00 15.00 7.91 13.60 0.00 0.00 13.60 34.22 24.00 N/A N/A 0.013 0.00363 0.0229 583.55 583.27 0.00 4.33 0.00 0.29 1.25 0.00 0.36 583.91 579.47 581.19 586.19
LINE H
733.17 743.07 9.90 H-03 0.27 0.27 0.90 1.11 0.27 0.27 10.00 0.00 10.00 9.24 2.49 0.00 0.00 2.49 22.89 18.00 N/A N/A 0.013 0.00056 0.0475 585.21 585.20 0.00 1.41 0.00 0.03 1.25 0.00 0.10 585.31 582.20 582.67 587.17
671.02 733.17 62.15 MH N/A 0.27 N/A N/A N/A 0.27 10.00 0.00 10.00 9.24 2.49 0.00 0.00 2.49 44.23 36.00 N/A N/A 0.013 0.00001 0.0044 585.10 585.10 1.41 0.35 0.03 0.00 0.50 0.02 0.10 585.20 580.42 580.70 586.78
597.91 671.02 73.11 H-02 0.31 0.58 0.90 1.11 0.31 0.58 10.00 3.06 13.06 8.37 4.84 0.00 0.00 4.84 44.23 36.00 N/A N/A 0.013 0.00005 0.0044 585.00 585.00 0.35 0.68 0.00 0.01 0.75 0.00 0.10 585.10 580.10 580.42 587.17
533.58 597.91 64.33 H-01 5.23 5.81 0.50 1.25 3.27 3.85 15.00 4.84 19.84 6.98 26.88 0.00 0.00 26.88 44.23 36.00 N/A N/A 0.013 0.00163 0.0044 584.78 584.67 0.68 3.80 0.01 0.22 0.75 0.01 0.22 585.00 579.82 580.10 586.38
478.89 533.58 54.69 H-05 1.59 7.40 0.50 1.25 0.99 4.84 15.00 5.12 20.12 6.94 33.60 0.00 0.00 33.60 44.23 36.00 N/A N/A 0.013 0.00254 0.0044 584.49 584.35 3.80 4.75 0.22 0.35 0.75 0.17 0.18 584.67 579.58 579.82 587.18
403.32 478.89 75.57 H-04, MH 0.70 8.10 0.50 1.25 0.44 5.28 15.00 5.31 20.31 6.91 36.47 0.00 0.00 36.47 92.29 N/A 4.00 3.00 0.013 0.00087 0.0056 584.25 584.19 4.75 3.04 0.35 0.14 0.50 0.18 0.10 584.35 579.16 579.58 586.67
336.74 403.32 66.58 H-06 0.66 8.76 0.50 1.25 0.41 5.69 15.00 5.73 20.73 6.84 38.92 0.00 0.00 38.92 92.29 N/A 4.00 3.00 0.013 0.00099 0.0056 584.09 584.02 3.04 3.24 0.14 0.16 0.75 0.11 0.10 584.19 578.79 579.16 586.30
289.39 336.74 47.35 H-08 0.43 9.18 0.90 1.11 0.43 6.12 15.00 6.07 21.07 6.79 41.50 0.00 0.00 41.50 92.29 N/A 4.00 3.00 0.013 0.00112 0.0056 583.92 583.87 3.24 3.46 0.16 0.19 0.75 0.12 0.10 584.02 578.52 578.79 585.74
193.06 289.39 96.33 H-07, H-09 1.53 10.71 0.58 1.22 1.08 7.19 15.00 6.30 21.30 6.75 48.56 0.00 0.00 48.56 92.29 N/A 4.00 3.00 0.013 0.00154 0.0056 583.75 583.60 3.46 4.05 0.19 0.25 0.75 0.14 0.12 583.87 577.99 578.52 585.74
100.00 193.06 93.06 H-10, H-11, H12 3.01 13.72 0.81 1.25 3.04 10.23 15.00 6.69 21.69 6.69 68.48 0.00 0.00 68.48 122.47 N/A 5.00 3.00 0.013 0.00174 0.0056 583.47 583.31 4.05 4.57 0.25 0.32 0.75 0.19 0.13 583.60 577.47 577.99 584.57
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDC04.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDC04.dgn1:404:42:06 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837NTS
E. OF LOOP 288 TO W. OF GRISSOM ROAD
DRAINAGE CALCULATIONS
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
200
McKINNEY STREET STORM DRAIN CALCULATIONS
From To Pipe Drainage Area Runoff "c"Frequency Factor Inc. c*Cf*A Total c*Cf*A Time of Concentration 100-yr.100-yr.Inlet Inlet "Q" Actual "Q" Pipe Pipe Size Box Size n Sf Spipe HGL Head Loss Calculations Design HGL Invert Elevation T/C or Comments
Length Incremental Total Area Cf Inlet Travel Total Intensity Runoff Carryover Carryover Capacity Diameter Width Height Ground Elev
Area No.Area (To Inlet)"Q" (From Inlet)U/S D/S V1 (in)V2 (out)/2g 2V1 /2g2V2 jK /2g2V1jK Head Loss From To
(Sta.)(Sta.)(Ft)(Acres)(Acres)(Min.)(Min.)(Min.)(in/hr)(cfs)(cfs)(cfs)(cfs)(cfs)(in)(ft)(ft)(ft/ft)(ft/ft)(ft)(ft)(ft/s)(ft/s)(ft)(ft) (ft) (ft) (ft) (ft) (ft) (ft)
LAT H-01
100.00 192.96 92.96 H-01 5.23 5.23 0.50 1.25 3.27 3.27 15.00 0.00 15.00 7.91 25.88 0.00 0.00 25.88 35.28 36.00 N/A N/A 0.013 0.00151 0.0028 585.14 585.00 0.00 3.66 0.00 0.21 1.25 0.00 0.26 585.40 580.10 580.36 586.36
LAT H-02
100.00 174.95 74.95 H-02 0.31 0.31 0.90 1.11 0.31 0.31 10.00 0.00 10.00 9.24 2.86 0.00 0.00 2.86 14.85 18.00 N/A N/A 0.013 0.00074 0.0200 585.16 585.10 0.00 1.62 0.00 0.04 1.25 0.00 0.10 585.26 581.17 582.67 587.17
LAT H-04
100.00 174.95 74.95 H-04 0.70 0.70 0.50 1.25 0.44 0.44 15.00 0.00 15.00 7.91 3.46 0.00 0.00 3.46 14.05 18.00 N/A N/A 0.013 0.00109 0.0179 584.43 584.35 0.00 1.96 0.00 0.06 1.25 0.00 0.10 584.53 580.33 581.67 586.67
LAT H-05
120.03 163.63 43.60 H-05 1.59 1.59 0.50 1.25 0.99 0.99 15.00 0.00 15.00 7.91 7.86 0.00 0.00 7.86 8.00 18.00 N/A N/A 0.013 0.00564 0.0058 585.23 584.99 0.00 4.45 0.00 0.31 1.25 0.00 0.38 585.62 580.69 580.94 587.18
109.69 120.03 10.34 BEND N/A 1.59 N/A N/A N/A 0.99 15.00 0.00 15.00 7.91 7.86 0.00 0.00 7.86 8.00 18.00 N/A N/A 0.013 0.00564 0.0058 584.89 584.83 4.45 4.45 0.31 0.31 0.20 0.06 0.10 584.99 580.63 580.69 586.69
100.00 109.69 9.69 BEND N/A 1.59 N/A N/A N/A 0.99 15.00 0.00 15.00 7.91 7.86 0.00 0.00 7.86 8.00 18.00 N/A N/A 0.013 0.00564 0.0058 584.73 584.67 4.45 4.45 0.31 0.31 0.20 0.06 0.10 584.83 580.57 580.63 586.47
LAT H-06
100.00 174.70 74.70 H-06 0.66 0.66 0.50 1.25 0.41 0.41 15.00 0.00 15.00 7.91 3.25 0.00 0.00 3.25 16.70 18.00 N/A N/A 0.013 0.00096 0.0253 584.26 584.19 0.00 1.84 0.00 0.05 1.25 0.00 0.10 584.36 579.91 581.80 586.30
LAT H-07
150.64 174.64 24.00 H-07 0.29 0.29 0.90 1.11 0.29 0.29 10.00 0.00 10.00 9.24 2.71 0.00 0.00 2.71 34.25 24.00 N/A N/A 0.013 0.00014 0.0229 584.04 584.04 0.00 0.86 0.00 0.01 1.25 0.00 0.10 584.14 580.18 580.74 585.74
100.00 150.64 50.64 H-09 1.23 1.53 0.50 1.25 0.77 1.06 15.00 0.46 15.46 7.81 8.32 0.00 0.00 8.32 34.19 24.00 N/A N/A 0.013 0.00136 0.0229 583.94 583.87 0.86 2.65 0.01 0.11 0.75 0.01 0.10 584.04 579.03 580.18 585.81
LAT H-08
100.00 111.32 11.32 H-08 0.43 0.43 0.90 1.11 0.43 0.43 10.00 0.00 10.00 9.24 3.93 0.00 0.00 3.93 40.70 18.00 N/A N/A 0.013 0.00141 0.1502 584.04 584.02 0.00 2.22 0.00 0.08 1.25 0.00 0.10 584.14 579.54 581.24 585.74
LAT H-09
100.00 129.59 29.59 H-09 1.23 1.23 0.50 1.25 0.77 0.77 15.00 0.00 15.00 7.91 6.10 0.00 0.00 6.10 32.77 24.00 N/A N/A 0.013 0.00073 0.0210 584.06 584.04 0.00 1.94 0.00 0.06 1.25 0.00 0.10 584.16 580.19 580.81 585.81
LAT H-10
142.90 246.70 103.80 H-10 0.78 0.78 0.80 1.25 0.78 0.78 10.00 0.00 10.00 9.24 7.23 0.00 0.00 7.23 66.54 36.00 N/A N/A 0.013 0.00012 0.0100 583.85 583.84 0.00 1.02 0.00 0.02 1.25 0.00 0.10 583.95 578.37 579.40 585.40
100.00 142.90 42.90 H-11 2.02 2.81 0.80 1.25 2.02 2.81 10.00 1.69 11.69 8.73 24.50 0.00 0.00 24.50 66.54 36.00 N/A N/A 0.013 0.00135 0.0100 583.66 583.60 1.02 3.47 0.02 0.19 0.75 0.01 0.17 583.84 577.94 578.37 584.52
LAT H-11
100.00 169.86 69.86 H-11 2.02 2.02 0.80 1.25 2.02 2.02 10.00 0.00 10.00 9.24 18.69 0.00 0.00 18.69 30.55 36.00 N/A N/A 0.013 0.00079 0.0021 583.89 583.84 0.00 2.64 0.00 0.11 1.25 0.00 0.14 584.03 578.37 578.52 584.52
LAT H-12
100.00 111.32 11.32 H-12 0.21 0.21 0.90 1.11 0.21 0.21 10.00 0.00 10.00 9.24 1.93 0.00 0.00 1.93 41.63 18.00 N/A N/A 0.013 0.00034 0.1572 583.61 583.60 0.00 1.09 0.00 0.02 1.25 0.00 0.10 583.71 578.68 580.46 584.97
LINE I (Q/3)
1040.27 1068.00 27.73 I-01 63.65 63.65 N/A N/A N/A N/A 20.00 0.00 20.00 6.96 118.33 0.00 0.00 118.33 193.01 N/A 6.00 3.00 0.013 0.00331 0.0088 582.76 582.67 0.00 6.57 0.00 0.67 0.50 0.00 0.34 582.96 577.72 577.97 584.44
1011.51 1040.27 28.77 I-02 0.70 64.35 0.90 1.11 0.70 0.70 20.00 0.00 20.00 6.96 119.96 0.45 0.00 120.41 193.01 N/A 6.00 3.00 0.013 0.00342 0.0088 582.48 582.38 6.57 6.69 0.67 0.69 0.75 0.50 0.19 582.67 577.47 577.72 584.44
1000.00 1011.51 11.51 LINE H, LINE J 18.31 82.67 N/A N/A 13.58 14.29 20.00 0.14 20.14 6.93 151.35 0.52 0.97 151.35 193.01 N/A 6.00 3.00 0.013 0.00541 0.0088 582.38 582.32 6.69 8.41 0.69 1.10 0.25 0.17 0.92 582.38 577.37 577.47 584.44
LAT I-02
100.00 134.08 34.08 I-02 0.70 0.70 0.90 1.11 0.70 0.70 10.00 0.00 10.00 9.24 6.50 0.45 0.00 6.94 23.32 18.00 N/A N/A 0.013 0.00440 0.0493 582.82 582.67 0.00 3.93 0.00 0.24 1.25 0.00 0.30 583.12 578.26 579.94 584.44
LINE J
851.63 926.59 74.96 J-05 0.82 0.82 0.49 1.25 0.50 0.50 10.00 0.00 10.00 9.24 4.58 0.00 0.00 4.58 19.66 18.00 N/A N/A 0.013 0.00191 0.0350 586.33 586.19 0.00 2.59 0.00 0.10 1.25 0.00 0.13 586.46 585.22 587.85 592.35
831.63 851.63 20.00 MH N/A 0.82 N/A N/A N/A 0.50 10.00 0.00 10.00 9.24 4.58 0.00 0.00 4.58 21.21 24.00 N/A N/A 0.013 0.00041 0.0088 586.09 586.08 2.59 1.46 0.10 0.03 0.50 0.05 0.10 586.19 584.55 584.72 591.58
647.80 831.63 183.83 J-06 0.23 1.04 0.90 1.11 0.23 0.72 10.00 0.71 10.71 9.02 6.53 0.00 0.00 6.53 21.21 24.00 N/A N/A 0.013 0.00084 0.0088 585.98 585.83 1.46 2.08 0.03 0.07 0.75 0.02 0.10 586.08 582.93 584.55 590.72
438.65 647.80 209.15 J-04 0.86 1.90 0.48 1.25 0.51 1.24 10.00 2.19 12.19 8.60 10.63 0.00 0.00 10.63 21.21 24.00 N/A N/A 0.013 0.00222 0.0088 585.70 585.23 2.08 3.38 0.07 0.18 0.75 0.05 0.13 585.83 581.09 582.93 590.80
262.66 438.65 175.99 J-03 0.83 2.73 0.48 1.25 0.49 1.73 10.00 3.22 13.22 8.33 14.40 0.00 0.00 14.40 21.21 24.00 N/A N/A 0.013 0.00407 0.0088 585.04 584.32 3.38 4.58 0.18 0.33 0.75 0.13 0.19 585.23 579.54 581.09 589.20
233.98 262.66 28.68 J-01, MH 0.90 3.63 0.59 1.25 0.66 2.39 10.00 3.86 13.86 8.18 19.52 0.00 0.45 19.08 38.46 30.00 N/A N/A 0.013 0.00217 0.0088 584.22 584.16 4.58 3.89 0.33 0.23 0.50 0.16 0.10 584.32 578.79 579.04 586.43
119.47 233.98 114.51 J-02 0.68 4.31 0.90 1.11 0.68 3.07 10.00 3.98 13.98 8.15 25.02 0.00 0.52 24.06 38.13 30.00 N/A N/A 0.013 0.00345 0.0087 583.97 583.57 3.89 4.90 0.23 0.37 0.75 0.18 0.20 584.16 577.80 578.79 585.55
103.72 119.47 15.75 J-00 0.28 4.59 0.90 1.11 0.28 3.35 10.00 4.37 14.37 8.06 26.97 0.52 0.00 27.05 38.13 30.00 N/A N/A 0.013 0.00436 0.0087 583.38 583.31 4.90 5.51 0.37 0.47 0.75 0.28 0.19 583.57 577.66 577.80 584.44
LAT J-00
100.00 111.31 11.31 J-00 0.28 0.28 0.90 1.11 0.28 0.28 10.00 0.00 10.00 9.24 2.56 0.52 0.00 3.08 39.99 18.00 N/A N/A 0.013 0.00086 0.1450 583.58 583.57 0.00 1.74 0.00 0.05 1.25 0.00 0.10 583.68 578.30 579.94 584.44
LAT J-01
100.00 160.80 60.80 J-01 0.90 0.90 0.59 1.25 0.66 0.66 10.00 0.00 10.00 9.24 6.10 0.00 0.45 5.65 23.41 18.00 N/A N/A 0.013 0.00291 0.0497 584.50 584.32 0.00 3.20 0.00 0.16 1.25 0.00 0.20 584.70 579.79 582.81 586.43
LAT J-02
100.00 111.32 11.32 J-02 0.68 0.68 0.90 1.11 0.68 0.68 10.00 0.00 10.00 9.24 6.32 0.00 0.52 5.80 41.41 18.00 N/A N/A 0.013 0.00306 0.1555 584.20 584.16 0.00 3.28 0.00 0.17 1.25 0.00 0.21 584.41 579.29 581.05 585.55
LAT J-03
100.00 174.51 74.51 J-03 0.83 0.83 0.48 1.25 0.49 0.49 10.00 0.00 10.00 9.24 4.54 0.00 0.00 4.54 22.30 18.00 N/A N/A 0.013 0.00188 0.0451 585.37 585.23 0.00 2.57 0.00 0.10 1.25 0.00 0.13 585.50 581.34 584.70 589.20
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDC05.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDC05.dgn1:404:42:09 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837NTS
E. OF LOOP 288 TO W. OF GRISSOM ROAD
DRAINAGE CALCULATIONS
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
201
McKINNEY STREET STORM DRAIN CALCULATIONS
From To Pipe Drainage Area Runoff "c"Frequency Factor Inc. c*Cf*A Total c*Cf*A Time of Concentration 100-yr.100-yr.Inlet Inlet "Q" Actual "Q" Pipe Pipe Size Box Size n Sf Spipe HGL Head Loss Calculations Design HGL Invert Elevation T/C or Comments
Length Incremental Total Area Cf Inlet Travel Total Intensity Runoff Carryover Carryover Capacity Diameter Width Height Ground Elev
Area No.Area (To Inlet)"Q" (From Inlet)U/S D/S V1 (in)V2 (out)/2g 2V1 /2g2V2 jK /2g2V1jK Head Loss From To
(Sta.)(Sta.)(Ft)(Acres)(Acres)(Min.)(Min.)(Min.)(in/hr)(cfs)(cfs)(cfs)(cfs)(cfs)(in)(ft)(ft)(ft/ft)(ft/ft)(ft)(ft)(ft/s)(ft/s)(ft)(ft) (ft) (ft) (ft) (ft) (ft) (ft)
LAT J-04
100.00 174.63 74.63 J-04 0.86 0.86 0.48 1.25 0.51 0.51 10.00 0.00 10.00 9.24 4.74 0.00 0.00 4.74 21.47 18.00 N/A N/A 0.013 0.00205 0.0418 585.98 585.83 0.00 2.68 0.00 0.11 1.25 0.00 0.14 586.12 583.18 586.30 590.80
LAT J-06
100.00 111.32 11.32 J-06 0.23 0.23 0.90 1.11 0.23 0.23 10.00 0.00 10.00 9.24 2.10 0.00 0.00 2.10 49.94 18.00 N/A N/A 0.013 0.00040 0.2262 586.08 586.08 0.00 1.19 0.00 0.02 1.25 0.00 0.10 586.18 584.80 587.36 590.72
LINE K
687.85 761.38 73.53 K-01 0.45 0.45 0.90 1.11 0.45 0.45 10.00 0.00 10.00 9.24 4.17 0.00 0.10 4.07 17.00 18.00 N/A N/A 0.013 0.00151 0.0262 584.94 584.83 0.00 2.30 0.00 0.08 1.25 0.00 0.10 585.04 581.18 583.11 587.62
661.43 687.85 26.42 MH N/A 0.45 M/A N/A N/A 0.45 10.00 0.00 10.00 9.24 4.17 0.00 0.00 4.07 8.93 18.00 N/A N/A 0.013 0.00151 0.0072 584.73 584.69 2.30 2.30 0.08 0.08 0.50 0.04 0.10 584.83 580.99 581.18 586.50
372.03 661.43 289.40 K-02 0.42 0.87 0.90 1.11 0.42 0.87 10.00 0.72 10.72 9.01 7.84 0.00 0.00 7.74 8.89 18.00 N/A N/A 0.013 0.00546 0.0072 584.45 582.87 2.30 4.38 0.08 0.30 0.75 0.06 0.24 584.69 578.92 580.99 586.69
366.43 372.03 5.60 N/A N/A 0.87 N/A N/A N/A 0.87 10.00 0.72 10.72 9.01 7.84 0.00 0.00 7.74 16.31 24.00 N/A N/A 0.013 0.00118 0.0052 582.77 582.77 4.38 2.46 0.30 0.09 1.00 0.30 0.10 582.87 578.39 578.42 584.19
331.43 366.43 35.00 K-03 0.47 1.34 0.90 1.11 0.47 1.34 10.00 0.04 10.04 9.23 12.33 0.10 0.00 12.33 16.34 24.00 N/A N/A 0.013 0.00298 0.0052 582.60 582.49 2.46 3.92 0.09 0.24 0.75 0.07 0.17 582.77 578.20 578.39 584.92
202.65 331.43 128.78 K-04 0.36 1.69 0.90 1.11 0.36 1.69 10.00 1.97 11.97 8.66 14.67 0.00 0.00 14.67 16.34 24.00 N/A N/A 0.013 0.00422 0.0052 582.33 581.79 3.92 4.67 0.24 0.34 0.75 0.18 0.16 582.49 577.53 578.20 584.35
104.55 202.65 98.10 K-05, K-06 0.44 2.14 0.90 1.11 0.44 2.14 10.00 2.43 12.43 8.53 18.24 0.00 0.00 18.24 16.34 24.00 N/A N/A 0.013 0.00653 0.0052 581.52 580.88 4.67 5.81 0.34 0.52 0.75 0.25 0.27 581.79 577.02 577.53 583.07
LAT K-02
100.00 111.31 11.31 K-02 0.42 0.42 0.90 1.11 0.42 0.42 10.00 0.00 10.00 9.24 3.86 0.00 0.10 3.76 34.06 18.00 N/A N/A 0.013 0.00129 0.1052 584.70 584.69 0.00 2.13 0.00 0.07 1.25 0.00 0.10 584.80 581.00 582.19 586.69
LAT K-03
100.00 174.95 74.95 K-03 0.47 0.47 0.90 1.11 0.47 0.47 10.00 0.00 10.00 9.24 4.31 0.00 0.00 4.31 16.17 18.00 N/A N/A 0.013 0.00170 0.0237 582.89 582.77 0.00 2.44 0.00 0.09 1.25 0.00 0.12 583.01 578.64 580.42 584.92
LAT K-04
100.00 111.31 11.31 K-04 0.36 0.36 0.90 1.11 0.36 0.36 10.00 0.00 10.00 9.24 3.31 0.10 0.00 3.41 36.81 18.00 N/A N/A 0.013 0.00106 0.1229 582.51 582.49 0.00 1.93 0.00 0.06 1.25 0.00 0.10 582.61 578.46 579.85 584.35
LAT K-05
153.31 224.19 70.88 K-05 0.32 0.32 0.90 1.11 0.32 0.32 10.00 0.00 10.00 9.24 2.91 0.00 0.00 2.91 24.04 24.00 N/A N/A 0.013 0.00017 0.0113 581.92 581.91 0.00 0.93 0.00 0.01 1.25 0.00 0.10 582.02 578.14 578.94 583.94
100.00 153.31 53.31 K-06 0.13 0.44 0.90 1.11 0.13 0.44 10.00 1.27 11.27 8.85 3.92 0.00 0.00 3.92 24.04 24.00 N/A N/A 0.013 0.00030 0.0113 581.81 581.79 0.93 1.25 0.01 0.02 0.75 0.01 0.10 581.91 577.54 578.14 583.07
LAT K-06
100.00 143.31 43.31 K-06 0.13 0.13 0.90 1.11 0.13 0.13 10.00 0.00 10.00 9.24 1.18 0.00 0.00 1.18 7.28 18.00 N/A N/A 0.013 0.00013 0.0048 581.91 581.91 0.00 0.67 0.00 0.01 1.25 0.00 0.10 582.01 578.36 578.57 583.07
LINE L (Q/3)
111.50 169.36 57.86 L-01 N/A 0.00 N/A N/A N/A N/A 20.00 0.00 20.00 6.96 116.70 0.00 0.00 116.70 110.90 N/A 7.00 3.00 0.013 0.00221 0.0020 581.32 580.88 0.00 5.56 0.00 0.48 0.50 0.00 0.48 581.80 576.82 576.94 582.77
100.00 111.50 11.50 LINE K, LINE M 4.04 4.04 N/A N/A N/A N/A 20.00 0.00 20.00 6.96 171.75 0.00 0.00 171.75 110.90 N/A 7.00 3.00 0.013 0.00480 0.0020 580.20 580.14 5.56 8.18 0.48 1.04 0.75 0.36 0.68 580.88 576.80 576.82 582.89
LINE M
295.61 338.83 43.22 EX. 3'X2' RBC N/A N/A N/A N/A N/A N/A 22.57 0.00 22.57 6.56 24.48 0.00 0.00 24.48 21.82 N/A 3.00 2.00 0.013 0.00252 0.0020 582.61 582.50 4.08 4.08 0.26 0.26 0.00 0.00 0.10 582.71 577.35 577.44 583.67
268.58 295.61 27.03 M-04 0.34 0.34 0.90 1.11 0.34 0.34 22.57 0.00 22.57 6.56 26.71 0.00 0.00 26.71 21.82 N/A 3.00 2.00 0.013 0.00300 0.0020 582.39 582.31 4.08 4.45 0.26 0.31 0.75 0.19 0.11 582.50 577.30 577.35 583.50
200.61 268.58 67.97 M-03 0.67 1.01 0.90 1.11 0.67 1.01 22.57 0.28 22.85 6.52 31.04 0.26 0.04 31.26 21.82 N/A 3.00 2.00 0.013 0.00410 0.0020 582.12 581.84 4.45 5.21 0.31 0.42 0.75 0.23 0.19 582.31 577.16 577.30 583.67
158.01 200.61 42.60 BEND N/A 1.01 N/A N/A N/A 1.01 22.57 0.28 22.85 6.52 31.04 0.00 0.00 31.26 21.82 N/A 3.00 2.00 0.013 0.00410 0.0020 581.74 581.56 5.21 5.21 0.42 0.42 0.20 0.08 0.10 581.84 577.08 577.16 583.50
134.18 158.01 23.83 M-01 0.46 1.47 0.90 1.11 0.46 1.47 22.57 0.63 23.20 6.47 33.98 0.00 0.00 33.94 21.82 N/A 3.00 2.00 0.013 0.00484 0.0020 581.38 581.27 5.21 5.66 0.42 0.50 0.75 0.32 0.18 581.56 577.03 577.08 582.77
103.75 134.18 30.43 M-02 0.44 1.91 0.90 1.11 0.44 1.91 22.57 0.70 23.27 6.46 36.81 0.04 0.00 36.84 21.82 N/A 3.00 2.00 0.013 0.00570 0.0020 581.05 580.88 5.66 6.14 0.50 0.59 0.75 0.37 0.21 581.27 576.97 577.03 582.77
LAT M-01
100.00 111.29 11.29 M-01 0.46 0.46 0.90 1.11 0.46 0.46 10.00 0.00 10.00 9.24 4.27 0.00 0.00 4.27 30.31 18.00 N/A N/A 0.013 0.00166 0.0833 581.58 581.56 0.00 2.42 0.00 0.09 1.25 0.00 0.11 581.69 577.33 578.27 582.77
LAT M-02
100.00 164.54 64.54 M-02 0.44 0.44 0.90 1.11 0.44 0.44 10.00 0.00 10.00 9.24 4.06 0.04 0.00 4.10 12.99 18.00 N/A N/A 0.013 0.00154 0.0153 581.37 581.27 0.00 2.32 0.00 0.08 1.25 0.00 0.10 581.47 577.28 578.27 582.77
LAT M-03
100.00 185.05 85.05 M-03 0.67 0.67 0.90 1.11 0.67 0.67 10.00 0.00 10.00 9.24 6.15 0.26 0.04 6.37 14.47 18.00 N/A N/A 0.013 0.00370 0.0190 582.62 582.31 0.00 3.61 0.00 0.20 1.25 0.00 0.25 582.87 577.55 579.17 583.67
LAT M-04
100.00 105.59 5.59 M-04 0.34 0.34 0.90 1.11 0.34 0.34 10.00 0.00 10.00 9.24 3.13 0.00 0.00 3.13 52.60 18.00 N/A N/A 0.013 0.00090 0.2509 582.51 582.50 0.00 1.77 0.00 0.05 1.25 0.00 0.10 582.61 577.60 579.00 583.50
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDC06.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDC06.dgn1:404:42:12 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837NTS
E. OF LOOP 288 TO W. OF GRISSOM ROAD
DRAINAGE CALCULATIONS
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
202
McKINNEY STREET PHASE TWO RUNOFF CALCULATIONS-TXDOT
TOTAL ARE WEIGHTED INTENSITY "Q-5"INTENSITY "Q-100"
AREA "A""C"Tc "I-5"RUNOFF "I-100"RUNOFF
NO. (ACRES)VALUE (MIN.)(IN./HR)(CFS)(IN./HR)(CFS)
A-01 0.75 0.90 10.00 6.07 4.09 10.99 7.39
A-02 2.40 0.70 10.00 6.07 10.20 10.99 18.46
A-03 2.29 0.80 10.00 6.07 4.06*10.99 7.84*
A-04 0.39 0.90 10.00 6.07 2.15 10.99 3.89
A-05 0.05 0.90 10.00 6.07 0.28 10.99 0.52
B-01 0.63 0.90 10.00 6.07 3.45 10.99 6.25
B-02 0.47 0.90 10.00 6.07 2.58 10.99 4.67
McKINNEY STREET PHASE TWO STORM DRAIN CALCULATIONS-TXDOT
From To Pipe Drainage Area Runoff "c"Inc. c*A Total c*A Time of Concentration 5-yr.5-yr.Inlet Inlet "Q" Actual "Q" Pipe Pipe Size Box Size n Sf Spipe HGL Head Loss Calculations Design HGLInvert Elevation T/C or Comments
Length Incremental Total Area Inlet Travel Total Intensity Runoff Carryover Carryover Capacity Diameter Width Height Ground Elev
Area No.Area (To Inlet)"Q" (From Inlet)U/S D/S V1 (in)V2 (out)/2g 2V1 /2g2V2 jK /2g2V1jK Head Loss From To
(Sta.)(Sta.)(Ft)(Acres (Acres)(Min.)(Min.)(Min.)(in/hr)(cfs)(cfs)(cfs)(cfs)(cfs)(in)(ft)(ft)(ft/ft)(ft/ft)(ft)(ft)(ft/s)(ft/s)(ft)(ft) (ft) (ft) (ft) (ft) (ft) (ft)
LINE A
900.25 960.36 60.11 A-03 N/A N/A N/A N/A N/A 10.00 0.00 10.00 6.07 7.84 0.00 0.00 7.84 33.47 24.00 N/A N/A 0.013 0.00121 0.0219 585.29 585.22 0.00 2.50 0.00 0.10 1.25 0.00 0.12 585.42 584.42 585.74 590.74
646.17 900.25 254.08 MH N/A N/A N/A N/A N/A 10.00 0.00 10.00 6.07 7.84 0.00 0.00 7.84 10.11 24.00 N/A N/A 0.013 0.00121 0.0020 585.12 584.82 2.50 2.50 0.10 0.10 0.50 0.05 0.10 585.22 583.92 584.42 589.71
578.31 646.17 67.86 A-04 0.39 0.39 0.90 0.35 0.35 10.00 0.00 10.00 6.07 9.99 0.00 0.00 9.99 10.11 24.00 N/A N/A 0.013 0.00196 0.0020 584.72 584.58 2.50 3.18 0.10 0.16 0.75 0.07 0.10 584.82 583.78 583.92 588.99
490.69 578.31 87.62 A-02, MH 2.40 2.79 0.70 1.68 2.03 10.00 2.45 12.45 5.48 18.99 0.00 0.00 18.99 31.21 N/A 4.00 2.00 0.013 0.00074 0.0020 584.48 584.42 3.18 2.37 0.16 0.09 0.50 0.08 0.10 584.58 583.61 583.78 588.43
374.34 490.69 116.35 BEND N/A 2.79 N/A N/A 2.03 10.00 2.45 12.45 5.48 18.99 0.00 0.00 18.99 31.21 N/A 4.00 2.00 0.013 0.00074 0.0020 584.32 584.23 2.37 2.37 0.09 0.09 0.20 0.02 0.10 584.42 583.37 583.61 588.84
312.34 374.34 62.00 BEND N/A 2.79 N/A N/A 2.03 10.00 2.45 12.45 5.48 18.99 0.00 0.00 18.99 31.21 N/A 4.00 2.00 0.013 0.00074 0.0020 584.13 584.09 2.37 2.37 0.09 0.09 0.20 0.02 0.10 584.23 583.25 583.37 588.04
258.57 312.34 53.77 BEND N/A 2.79 N/A N/A 2.03 10.00 2.45 12.45 5.48 18.99 0.00 0.00 18.99 31.21 N/A 4.00 2.00 0.013 0.00074 0.0020 583.99 583.95 2.37 2.37 0.09 0.09 0.20 0.02 0.10 584.09 583.14 583.25 587.78
241.60 258.57 16.97 BEND N/A 2.79 N/A N/A 2.03 10.00 2.45 12.45 5.48 18.99 0.00 0.00 18.99 31.21 N/A 4.00 2.00 0.013 0.00074 0.0020 583.85 583.83 2.37 2.37 0.09 0.09 0.20 0.02 0.10 583.95 583.11 583.14 587.98
230.00 241.60 11.60 A-01 0.75 3.54 0.90 0.67 2.71 10.00 4.82 14.82 5.02 21.43 0.00 0.00 21.43 31.21 N/A 4.00 2.00 0.013 0.00094 0.0020 583.73 583.72 2.37 2.68 0.09 0.11 0.75 0.07 0.10 583.83 583.08 583.11 587.85
147.91 230.00 82.09 PVI N/A 3.54 N/A N/A 2.71 10.00 4.82 14.82 5.02 21.43 0.00 0.00 21.43 133.14 N/A 4.00 2.00 0.013 0.00094 0.0364 583.62 583.55 2.68 2.68 0.11 0.11 0.30 0.03 0.10 583.72 580.10 583.08 587.98
100.00 147.91 47.91 BEND N/A 3.54 N/A N/A 2.71 10.00 4.82 14.82 5.02 21.43 0.00 0.00 21.43 31.21 N/A 4.00 2.00 0.013 0.00094 0.0020 583.45 583.40*2.68 2.68 0.11 0.11 0.28 0.03 0.10 583.55 580.00 580.10 587.97
LINE B
555.94 566.95 11.01 B-02 0.47 0.47 0.90 0.43 0.43 10.00 0.00 10.00 6.07 2.58 0.00 0.00 2.58 4.86 18.00 N/A N/A 0.013 0.00061 0.0021 585.72 585.72 0.00 1.46 0.00 0.03 1.25 0.00 0.10 585.82 584.97 584.99 588.99
240.45 555.94 315.49 MH N/A 0.47 N/A N/A 0.43 10.00 0.00 10.00 6.07 2.58 0.00 0.00 2.58 4.86 18.00 N/A N/A 0.013 0.00061 0.0021 585.62 585.42 1.46 1.46 0.03 0.03 0.50 0.02 0.10 585.72 584.29 584.97 588.61
211.89 240.45 28.56 B-01 0.63 1.10 0.90 0.57 0.99 10.00 3.73 13.73 5.22 5.19 0.00 0.00 5.19 10.43 24.00 N/A N/A 0.013 0.00053 0.0021 585.32 585.31 1.46 1.65 0.03 0.04 0.75 0.02 0.10 585.42 584.23 584.29 588.36
196.29 211.89 15.60 BEND N/A 1.10 N/A N/A 0.99 10.00 3.73 13.73 5.22 5.19 0.00 0.00 5.19 10.43 24.00 N/A N/A 0.013 0.00053 0.0021 585.21 585.20 1.65 1.65 0.04 0.04 0.35 0.01 0.10 585.31 584.20 584.23 588.02
125.72 196.29 70.57 BEND N/A 1.10 N/A N/A 0.99 10.00 3.73 13.73 5.22 5.19 0.00 0.00 5.19 13.11 24.00 N/A N/A 0.013 0.00053 0.0034 585.10 585.06 1.65 1.65 0.04 0.04 0.35 0.01 0.10 585.20 583.96 584.20 587.97
100.87 125.72 24.85 BEND N/A 1.10 N/A N/A 0.99 10.00 3.73 13.73 5.22 5.19 0.00 0.00 5.19 13.11 24.00 N/A N/A 0.013 0.00053 0.0034 584.96 584.95*1.65 1.65 0.04 0.04 0.28 0.01 0.10 585.06 583.88 583.96 588.56
ASSOCIATED CONSTRUCTION CHANGE ORDER #29 FROM JANUARY, 2009.
* STARTING DESIGN HGL ELEVATIONS FROM LOOP 288 PLANS DESIGNED IN 2005 AND
DESIGN OF THIS POND WAS FOR THE OAK HILL BUSINESS PARK IN JULY, 2007.
TO RELEASE 4.06 CFS IN A 5 YEAR STORM AND 7.84 CFS IN A 100 YEAR STORM.
* DRAINAGE AREA A-03 CONTAINS AN EXISTING DETENTION POND THAT WAS DESIGNED
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDC07.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CDC07.dgn1:404:42:15 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837NTS
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
TXDOT DRAINAGE CALCULATIONS
1"=40'H
1"=10'V
NOTES:CITY OF DENTON - McKINNEY STREET PHASE TWOINFORMATION.
PROFILE SHEETS FOR ADDITIONAL
SEE WATER AND WASTEWATER PLAN AND 3.
FOR ADDITIONAL INFORMATION.
2. SEE PAVING PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE DRAINAGE AREA MAP
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LINE-A_01.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LINE-A_01.dgn1:404:42:22 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
LINE A
STORM DRAIN PLAN & PROFILE
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
V
PARKING AREA
PARKING AREA
E
PARKING AREA
S
S
S
101 S LOOP 288
SEJ ASSET MANAGEMENT & INVESTMENT COMPANY
LOOP 288
7-ELEVEN INC
LOT 1
LOT 24A
VOL. 1029, PG. 281
UTILITY EASEMENT
75' MAINTAINING PUBLIC
VOL. 603, PG. 520
EASEMENT
16' PUBLIC UTILITY
VOL. 603, PG. 520
EASEMENT
16' PUBLIC UTILITY
D.R.D.C.T.
PG. 394
VOL. 440,
EASEMENT
DRAINAGE
40' TXDOT
CAB. R, PG. 32
EASEMENT
20' PUBLIC UTILITY
LOT 1
100 N LOOP 288
100 NORTH LOOP 288, LLC
WV
WV
WV
WV WV
LT
LT
LT
LT
3
0
" WW3
0" WW3
0" WW8" WW8" WW 8" WW
8" W
8" W8" W8" W20" W
20" W
8" W8" W
8" W 8" W
24" RCP BOX
C
UL
VE
R
T
E
x.
9'
x
5' BOX CUL
VE
R
T
E
x.
5'
x
4'
B
OX CUL
VE
RT
E
x.
5'
x
4' BOX
C
UL
VE
RT
E
x.
5'
x
4'
B
OX CUL
VE
R
TEx.
5'
x
3'
B
O
X CUL
VE
RT
E
x.
6'
x
3'
24" RCP 24" RCP
24" RCP
24" RCP
24" RCP
18" RCP
24" RCP
WV
8" W
20" W
PT 90+20.1890+00 91+00 92+00 93+00
1
0
0
7
2
+
0
0
1
0
0
7
3
+
0
0
1
0
0
7
4
+
0
0
89+00
4+003+00
2+00
24" RCP 18" RCP
1+00
2+00
3+
00
4+005+00
4'X2' RCB
12" W 12" W
20" W
12" W
20"
W
SLEEVES6" PVC BEGIN LINE AEX. 5'X4'RCBCONNECT TO1+00.00 LINE APVI2+30.00 LINE ACONSTRUCT CONC COLLARCONNECT TO EX. 24" RCP2+41.60 LINE AINSTALL 10.78°BEND2+58.57 LINE AINSTALL 15°BEND3+12.34 LINE AINSTALL 15°BEND3+74.34 LINE AINSTALL 15°BEND4+90.69 LINE ALINE A
ON 0.20%PROP. 4'X2' RCB ON 3.64% PROP. 4'X2' RCB
EX. GAS
ON 0.20%
PROP. 4'X2' RCB PVIINSTALL 30°BEND1+47.91 LINE AV=4.28 FPS
S=0.00241 FT/FT
C=31.21 CFS
Q100=34.27 CFS
V=4.28 FPS
S=0.00241 FT/FT
C=133.14 CFS
Q100=34.27 CFS
V=4.28 FPS
S=0.00241 FT/FT
C=31.21 CFS
Q100=34.27 CFS
V=3.64 FPS
S=0.00174 FT/FT
C=31.21 CFS
Q100=29.13 CFS
AT PIPE CL
PR. GRADE
AT PIPE CL
EX. GROUND
100 YEAR HGLHG 585.00 HG 585.22HG 585.12HG 585.51HG 585.41HG 585.67HG 585.54HG 585.80HG 585.70HG 586.00HG 585.90HG 586.20HG 586.10HG 586.51HG 586.41FL 570.02 +/-
EX. 30" WW
5 YEAR HGL
BY OTHERS
TO BE RELOCATED
FIBER & TRAFFIC SIGNAL CABLE
FL 581.85+/-
W/ 14" CASING
EX. 8" WATER
TO BE KILLED
EX. 8" WATER
1+00 2+00 3+00 4+00 5+00FL 4'X2'=580.17FL 4'X2'=581.99FL 4'X2'=583.12FL 4'X2'=583.22FL 4'X2'=583.32FL 4'X2'=583.42FL 4'X2'=583.52FL 4'X2'=583.62FL 4'X2'=583.08FL 4'X2'=580.00FL EX. 5'X4'=580.00583.05FL EX. 5'X3'FL 4'X2'=580.10FL EX. 24"=583.11FL 4'X2'=583.11585
580
570
565
575
590
595
600
LINE A
585
580
570
565
575
590
595
600
END LAT A-06F.L. 584.30T.C. 588.80CL 20' REC. INLETPAV STA 86+27.50, 50.50' RT1+27.75 LAT A-06
McKINNEY STREET
S
L
OOP
2
8
8N
L
OOP
2
8
8
END LAT C-XXTIE TO EX. 9'x5' BOX CULVERTPAV STA 88+62.75, 52.47' RT1+87.29 LAT C-XX
PC CV A-1INSTALL 45° BEND1+30.36 LINE A
EX. R.O.W
EX. R.O.W
MATCHLINE STA 5+00
PC CV A-1INSTALL 45° BEND1+30.36 LINE A
LINE B
MATCHLINE LINE A STA 5+00203
INSTALL 30°BEND
PAV STA 89+55.66,74.23' LT
1+47.91 LINE A
CONSTRUCT CONCRETE COLLAR
CONNECT TO EX. 24" RCP
PAV STA 90+43.72, 64.78' LT
2+41.60 LINE A
INSTALL 10.78° BEND
PAV STA 90+60.65, 63.53' LT
2+58.57 LINE A
INSTALL 15°BEND
PAV STA 91+12.59, 49.61' LT
3+12.34 LINE A
INSTALL 15°BEND
PAV STA 91+74.58, 49.61' LT
3+74.34 LINE A
INSTALL 15°BEND
PAV STA 92+86.97, 19.50' LT
4+90.69 LINE A
BEGIN LINE A
CONNECT TO EX. 5'X4' RCB
PAV STA 89+13.82,57.66' LT
1+00.00 LINE A
19.5'400 LF 4'x2' RCB
EX. 5'X3' BOX
TUNNEL UNDER
1"=40'H
1"=10'V
NOTES:CITY OF DENTON - McKINNEY STREET PHASE TWOINFORMATION.
PROFILE SHEETS FOR ADDITIONAL
SEE WATER AND WASTEWATER PLAN AND 3.
FOR ADDITIONAL INFORMATION.
2. SEE PAVING PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE DRAINAGE AREA MAP
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LINE-A_02.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LINE-A_02.dgn1:404:42:24 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
LINE A
STORM DRAIN PLAN & PROFILE
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
S
PARKING AREA
3701 E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
3730 E McKINNEY STREET
LISA FONG LEUNG
101 S LOOP 288
DNB INVESTMENTS LTD
LOT 1LOT 41
CAB. D, PG. 191
16' UTILITY EASEMENT
LOT 1
100 N LOOP 288
100 NORTH LOOP 288, LLC
8" WW
8" WW 8" WW
8" W 8" W 8" W 8" W
8" W
8" W 8" W
15" RCP
PT 94+85.56 PC 93+74.5993+00
94+00 95+00 96+00 97+00
12" W
12" W 12" W
20" W
20" W 20" W
12" W
SLEEVES6" PVC
SLEEVES6" PVC SLEEVES6" PVC SLEEVES6" PVC 6" W6" WD5+00
18" RCP 18" RCP 18"
24" RCP
5+00
6+00 7+00 8+00 9+00D
4'X2' RCB RCP30" 24" RCP18"
24" RCP
D
SQUARE SDMHCONSTRUCT 6'x6'1+00.00 LAT A-025+78.31 LINE A45°FACTORY WYE1+00.00 LAT A-046+46.17 LINE AON 0.20% CLASS III
PROP. 24" RCP ON 2.19% CLASS IIIPROP. 24" RCP SQUARE SDMHCONSTRUCT 4'x4'9+00.25 LINE AEND LINE ADROP INLETCONSTRUCT 4'X4'9+60.36 LINE ALINE A
ON 0.20%PROP. 4'X2' RCB
V=3.64 FPS
S=0.00174 FT/FT
C=31.21 CFS
Q100=29.13 CFS
V=3.65 FPS
S=0.00259 FT/FT
C=10.11 CFS
Q100=11.48 CFS
V=2.50 FPS
S=0.00121 FT/FT
C=10.11 CFS
Q100=7.48 CFS
V=2.50 FPS
S=0.00121 FT/FT
C=33.47 CFS
Q100=7.84 CFS
AT PIPE CL
PR. GRADE AT PIPE CL
EX. GROUND
FLOW
PARTIAL 100 YEAR HGLHG 586.76HG 586.66HG 587.07HG 586.94HG 587.48HG 587.38FL 580.16
PROP. 20" WATER
5 YEAR HGL
KILLED
TO BE
WATER
EX. 8"
FL 581.13+/-
PROP. 6" WATER
FL 581.48+/-
PROP. 6" WATER
5+00 6+00 7+00 8+00 9+00 10+00FL 21"=583.82FL 24"=583.92FL 24"=584.02FL 24"=584.12FL 24"=584.22FL 24"=584.32FL 24"=584.42FL 24"=585.51FL 4'X2'=583.72FL 4'X2'=583.78FL 30"= 583.78FL 18"=584.17FL 24"=583.92FL 24"=585.74585
580
570
565
575
590
595
600
585
580
570
565
575
590
595
600
McKINNEY STREET
CURVE 1 (CV A-1)
EX. R.O.W
EX. R.O.WMATCHLINE LINE A STA 5+00MATCHLINE LINE A STA 5+00CV A-1
PULL RCP AT JOINTS
R = 3,519.50'
L = 111.59'
T = 55.80'
DEG = 1° 37' 40.63"
= 1° 49' 00.00" RT
E = 2400350.75
N = 7127971.82
PI STA = 6+34.11
LINE A
LINE B
204
LAT A-02 LAT A-04
78.31 LF 4'x2' RCB 382.05 LF 24" RCP
LOT 1
3701 E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
END LINE A
F.L. 585.74
T.H. 590.74
TOP 591.74
CONSTRUCT 4'X4' DROP INLET
PAV STA 97+38.00, 63' LT
9+60.36 LINE A =
RIM 589.71
CONSTRUCT 4'X4' SQUARE SDMH
PAV STA 96+96.50, 19.50' LT
9+00.25 LINE A=
BEGIN LAT A-04
45° FACTORY WYE
1+00.00 LAT A-04
6+46.17 LINE A =
END LAT A-02
F.L. 583.93
T.H. 588.43
TOP 589.43
CONSTRUCT 4'X4' DROP INLET
PAV STA 93+90.00, 45.00' LT
1+29.50 LAT A-02 =19.5'END LAT A-04
F.L. 584.49
T.C. 588.99
CL 10' REC. INLET
PAV STA 94+50.00, 27.50' LT
1+11.30 LAT A-04 =
PT CV A-1
6+89.90 LINE A
PC CV A-1
RIM 588.82
BEGIN LAT A-02
SQUARE SDMH
CONSTRUCT 6'X6'
1+00.00 LAT A-02
19.50' LT
PAV STA 93+74.59,
5+78.31 LINE A =
1"=40'H
1"=10'V
NOTES:CITY OF DENTON - McKINNEY STREET PHASE TWOINFORMATION.
PROFILE SHEETS FOR ADDITIONAL
SEE WATER AND WASTEWATER PLAN AND 3.
FOR ADDITIONAL INFORMATION.
2. SEE PAVING PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE DRAINAGE AREA MAP
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LINE-B.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LINE-B.dgn1:404:42:27 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
LINE B
STORM DRAIN PLAN & PROFILE
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
V
PARKING AREA
PARKING AREA
E
PARKING AREA
S
S
S
101 S LOOP 288
DNB INVESTMENTS LTD
101 S LOOP 288
SEJ ASSET MANAGEMENT & INVESTMENT COMPANY
LOOP 288
7-ELEVEN INC
LOT 41LOT 1
LOT 24A
VOL. 603, PG. 520
EASEMENT
16' PUBLIC UTILITY
VOL. 603, PG. 520
EASEMENT
16' PUBLIC UTILITY
D.R.D.C.T.
PG. 394
VOL. 440,
EASEMENT
DRAINAGE
40' TXDOT
LOT 1
100 N LOOP 288
100 NORTH LOOP 288, LLC
CAB. R, PG. 32
EASEMENT
20' PUBLIC UTILITY
LOT 1
100 N LOOP 288
100 NORTH LOOP 288, LLC
WV
WV
WV
WV WV
LT
3
0" WW3
0" WW8" WW8" WW 8" WW 8" WW
8" W
8" W8" W8" W20" W
8" W8" W 8" W
8" W
8" W 8" W 8" W
BOX
C
UL
VE
RT
E
x.
5'
x
4'
B
OX CUL
VE
R
TEx.
5'
x
3'
B
O
X CUL
VE
RT
E
x.
6'
x
3'
24" RCP
24" RCP
24" RCP
24" RCP
18" RCP
24" RCP
WV
8" W
20" W
90+00 91+00 92+00 93+00 94+00
12" W 12" W 12" W
20" W
20" W
20" W
12" W
20"
W
SLEEVES6" PVC SLEEVES6" PVC SLEEVES6" PVC 6" WD
4+00 5+003+00
2+00
24" RCP 18" RCP 18" RCP 18" RCP 18"
24" RCP
2+00
3+
00
4+005+00 6+00
D
4'X2' RCB
4'X2' RCB
RCP30" 18"
2+00 3+00 4+00 5+00FL 24"=584.21FL 18"=584.32FL 18"=584.42FL 18"=584.53FL 18"=584.64FL 18"=584.74FL 18"=584.85FL 18"=584.95FL 24"=584.20FL 18"=584.99FL 24"=584.30FL 18"=584.30FL 24"=584.28FL 18"=584.28FL 24"=584.21FL 24"=584.22FL 18"=584.97BEGIN LINE BEX. 24" RCPCONNECT TO1+96.29 LINE BLINE B
EX. 24" RCP ON 0.34%CLASS III
18" RCP ON 0.21%END LINE B10' REC. INLET5+66.95 LINE BBEGIN 18" RCPEND 24" RCP2+40.45 LINE B45° FACTORY WYE1+00.00 LAT B-012+34.59 LINE B=INSTALL 15° BEND1+99.94 LINE BINSTALL 15° BEND2+11.89 LINE BCLASS III
ON 0.21%
24" RCP SQUARE SDMHCONSTRUCT 4'x4'5+55.94 LINE BAT PIPE CL
PR. GRADE
AT PIPE CL
EX. GRADE
V=2.47 FPS
S=0.00174 FT/FT
C=4.84 CFS
Q100=4.36 CFS
V=3.02 FPS
S=0.00177 FT/FT
C=10.43 CFS
Q100=9.49 CFS
AT PIPE CL
EX. GRADE HG 587.58HG 587.48HG 588.22HG 588.12HG 587.30HG 587.20HG 587.43HG 587.33HG 588.36HG 588.24100 YEAR HGL
5 YEAR HGL
FL 582.22+/-
PROP. 6" WATER
585
580
570
565
575
590
595
600
LINE B
585
580
570
565
575
590
595
600
McKINNEY STREET
S
L
OOP
2
8
8
END LAT C-XXTIE TO EX. 9'x5' BOX CULVERTPAV STA 88+62.75, 52.47' RT1+87.29 LAT C-XX
PC CV A-1INSTALL 45° BEND1+30.36 LINE A
EX. R.O.W
EX. R.O.W
LAT B-01
B
OX CUL
VE
R
T
E
x.
5'
x
3'
BEGIN LINE B
CONNECT TO EX. 24" RCP
PAV STA 90+82.66, 28.48' RT
1+96.29 LINE B
25.5'LINE B
326.50 LF 18" RCP44.16 LF 24" RCP
205
LINE A
END LAT B-01
F.L. 584.36
T.C. 588.36
CL 10' REC. INLET
PAV STA 91+25.00, 29.95' RT
1+06.29 LAT B-01
BEGIN LAT B-01
45° FACTORY WYE
1+00.00 LAT B-01
2+34.59 LINE B=
BEGIN 18" RCP
END 24"RCP
2+40.45 LINE B
INSTALL 15° BEND
2+11.89 LINE B
INSTALL 15° BEND
1+99.94 LINE B
RIM 588.61
CONSTRUCT 4'X4' SQUARE SDMH
PAV STA 94+42.93, 24.90' RT
5+55.94 LINE B
END LINE B
F.L. 584.99
T.C. 588.99
CL 10' REC. INLET
PAV STA 94+50.00, 33.50' RT
5+66.95 LINE B 6" W
1"=40'H
1"=10'V
NOTES:CITY OF DENTON - McKINNEY STREET PHASE TWOINFORMATION.
PROFILE SHEETS FOR ADDITIONAL
SEE WATER AND WASTEWATER PLAN AND 3.
FOR ADDITIONAL INFORMATION.
2. SEE PAVING PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE DRAINAGE AREA MAP
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LINE-C_01.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LINE-C_01.dgn1:404:42:30 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
LINE C
STORM DRAIN PLAN & PROFILE
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
V
V
PARKING AREA
PARKING AREA
DBL. 10" HACKBERRY
18" ELM 6" TREE
TRI 4" TREE
QUAD 6" ELM
S
S S
191 DUCHESS DRIVEJBJ/CALDER FUND VII JOINT VENTURE
E McKINNEY STREETMcKINNEY MAYHILL PARTNERS LLC
E McKINNEY STREET
CCD-RLG DENTON I LP
191 DUCHESS DRIVE
JBJ/CALDER FUND VII JOINT VENTURE
LOT 1
LOT 27
LOT 1
LOT 1
CAB. D, PG. 15
20' PUBLIC UTILITY EASEMENT
CAB. O, PG. 264
EASEMENT
15' PUBLIC UTILITY
CAB. O, PG. 264
10' UTILITY EASEMENT
CAB. O, PG. 264
10' UTILITY EASEMENT
CAB. D, PG. 15
20' PUBLIC UTILITY EASEMENT
CAB. O, PG. 26410' UTILITY EASEMENT
CAB. XX, PG. XX
EASEMENT
PRIVATE DRAINAGE
CAB. X, PG. XX
EASEMENT
8' PUBLIC UTILITY
WV
WV
8" WW 8" WW
8" W 8" W 8" W
8" W 6" W(15" STEEL ENCASEMENT)8" WW(15" STEEL ENCASEMENT)8" WW8
" W6" W 6" W
6" W6" W
6" W PC 99+35.08 PT 102+63.4299+00 100+00 101+00 102+00
103+00
12" W
12" W 12" W
20" W 20" W 20" W
20" W
12" W
6" W6" WSLEEVES
6" PVC
SLEEVES6" PVC 6" W6" W18" RCP
18" RCP 18" RCP
D18"10+00
11+00
12+0013+00
CLASS III
18" RCP ON 1.60%END LINE C10' REC. INLETSQUARE SDMHCONSTRUCT 4'X4'BEGIN 18" RCPEND 24" RCP13+09.12 LINE C12+97.80 LINE C10+05.63 LINE C10+01.78 LINE C=45° FACTORY WYE1+00 LAT C-04LINE C
12+51.99 LINE C=45° FACTORY WYE1+00 LAT C-02V=4.63 FPS
S=0.00611 FT/FT
C=13.27 CFS
Q100=8.18 CFS
AT PIPE CL
EX. GROUND PR. GRADE
AT PIPE CL HG 583.00HG 583.10100 YEAR HGL
FL 577.87+/-
PROP. 6" WATER
FLOW
PARTIAL HG 584.60HG 584.89V=1.99 FPS
S=0.00112 FT/FT
C=13.27 CFS
Q100=3.51 CFS
10+0011+0012+0013+00 FL 24"=578.82FL 18"=580.08FL 18"=580.88FL 18"=581.67FL 18"=582.47FL 18"=583.27FL 18"=584.03FL 18"=584.21FL 18"=579.37FL 24"=578.87FL 18"=583.30FL 18"=583.30FL 24"=578.84FL 18"=579.09FL 18"=584.07McKINNEY STREET
LINE C
LAT C-02
303.49 LF 18" RCP
BEGIN 18" RCP
END 24" RCP
10+05.63 LINE C
C-04
LAT
END LAT C-02
F.L. 582.30
T.C. 586.80
CL 10' REC. INLET
PAV STA 103+00.00, 27.50' LT
1+74.94 LAT C-04=
END LAT C-02
F.L. 584.21
T.C. 588.71
CL 10' REC. INLET
PAV STA 100+50.00, 27.50' LT
1+75.34 LAT C-02=
575
580
585
590
595
600
570
565565
570
575
580
585
590
595
600
BEGIN LAT C-04
45° FACTORY WYE
1+00.00 LAT C-04
10+01.78 LINE C=
BEGIN LAT C-02
45° FACTORY WYE
1+00.00 LAT C-02
12+51.99 LINE C=25.5'DUCHESS DRIVE206
3701 E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
LOT 1
3730 E McKINNEY STREET
LISA FONG LEUNG
LOT 1
MATCHLINE LINE C STA 10+00END LINE C
F.L. 584.21
T.C. 588.71
CL 10' REC. INLET
PAV STA 100+50.00, 33.50' RT
13+09.12 LINE C=MATCHLINE LINE C STA 10+005.63 LF 24" RCP
CURVE 1 (CV C-1)
PC CV C-1
RIM 588.26
CONSTRUCT 4'X4' SQUARE SDMH
PAV STA 100+57.96, 25.50' RT
12+97.80 LINE C
PULL RCP AT JOINTS
R = 5,275.50'
L = 192.42'
T = 96.22'
DEG = 1° 05' 09.86"
= 2° 05' 23.53" RT
E = 2400968.29
N = 7127589.79
PI STA = 12+01.60
CV C-1
PT CV C-1
11+05.38 LINE C
6" W
1"=40'H
1"=10'V
NOTES:CITY OF DENTON - McKINNEY STREET PHASE TWOINFORMATION.
PROFILE SHEETS FOR ADDITIONAL
SEE WATER AND WASTEWATER PLAN AND 3.
FOR ADDITIONAL INFORMATION.
2. SEE PAVING PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE DRAINAGE AREA MAP
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LINE-C_02.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LINE-C_02.dgn1:404:42:32 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
LINE C
STORM DRAIN PLAN & PROFILE
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
PARKING AREA
E
24" HACKBERRY
DBL. 12" TREE
24" TREE
TRI 6" TREEDBL. 8" HACKBERRY 6" ELM DBL. 6"/12" HACKBERRY DBL. 6" HACKBERRY DBL. 8" HACKBERRY
4" ELM
6" ELM
15" HACKBERRY
10" CEDAR
DBL. 10" TREEDBL. 12" HACKBERRYDBL. 6" ELM
10" TREE
S
S
CAB. O, PG. 264
10' UTILITY EASEMENT
CAB. B, PG. 7125' UTILITY EASEMENT
CAB. B, PG. 7116' UTILITY EASEMENT
WV
WV
WV
8" W
8" W
6" W
6" W6" W
6" W
6" W6" W
6" W
6" W
8" WW 8" WW
8" WW
8" W
8" W
6" W15" RCP
15" RCP
24" RCP
18" RCP PC 104+55.99 PT 107+79.73104+00
105+00 106+00
107+00
108+00
20" W
20" W 20" W
12" W
12" W 12" W
12" W
12" W
20" W
12" W12" WSLEEVES6" PVC
SLEEVES6" PVC
SLEEVES6" PVC
SLEEVES
6" PVC 6" W24" RCP
36" RCP
18"36" RCP
D
D
30"
R
CP
18"18"RCP36" 5+00
6+00
7+00
8+00
9+00
10+00 RCP18" RCB4'X4'
CLASS III
24" RCP ON 0.83%
CLASS III
36" RCP ON 0.20%45° FACTORY WYE1+00 LAT C-058+46.06 LINE C=7+63.23 LINE C=BEGIN 24" RCPEND 36" RCPSQUARE SDMHCONSTRUCT 6'X6'1+00 LAT C-0645° FACTORY WYE1+00 LAT C-096+78.57 LINE C=5+77.02 LINE C=45° FACTORY WYE1+00 LAT C-11BY OTHERS
RELOCATED
FIBER TO BE 5+49.72 LINE CPROP. 12" WATERLINE C
V=3.14 FPS
S=0.00191 FT/FT
C=20.60 CFS
Q100=9.86 CFS
V=4.38 FPS
S=0.00371 FT/FT
C=20.60 CFS
Q100=13.76 CFS
V=5.68 FPS
S=0.00363 FT/FT
C=29.82 CFS
Q100=40.16 CFS
V=6.05 FPS
S=0.00412 FT/FT
C=29.82 CFS
Q100=42.78 CFS
V=6.44 FPS
S=0.00466 FT/FT
C=29.82 CFS
Q100=45.51 CFS
V=3.93 FPS
S=0.00119 FT/FT
C=81.79 CFS
Q100=62.87 CFS
5+55.75 LINE C=AT PIPE CL
EX. GROUND
AT PIPE CL
PR. GRADE HG 582.51HG 582.69HG 581.85HG 582.20HG 581.35HG 581.54HG 580.71HG 580.93HG 580.51HG 580.61100 YEAR HGL
FL 571.01
W/ 18" ENCASEMENT
PROP. 12" WATER
FL 574.65+/-
PROP. 6" WATER
4'x4' RCB ON 0.20%BEGIN 36" RCPEND 4'X4' RCBSQUARE SDMHCONSTRUCT 6'X6'1+00 LAT C-087+00 6+00 5+008+009+0010+00 FL 36"=575.53FL 36"=575.63FL 36"=575.73FL 36"=575.83FL 24"=577.16FL 24"=577.57FL 24"=577.99FL 24"=578.41FL 36"=575.85FL 24"=576.85FL 24"=577.54FL 18"=577.79FL 36"=575.68FL 18"=576.43FL 36"=575.85FL 36"=575.48FL 18"=576.23FL 36"=575.44FL 4'x4'=574.33FL 4'x4'=574.43FL 4'x4'=574.44FL 30"=575.1925'
RIM XXX.XX
CONSTRUCT 4'X4' SQUARE SDMH
PAV STA 96+96.50, 19.50' LT
9+00.25 LINE A=
207MATCHLINE LINE C STA 10+00MATCHLINE LINE C STA 5+00LINE C
LAT C-05
LAT C-09
DONE BY OTHERS TO STA 119+50
CONTRACT, BEGIN WORK TO BE
STA 106+00 END WORK THIS
3912 E McKINNEY STREET
DUNCAN STREET COMMERCIAL LLC
LOT 2
3910 E McKINNEY STREET
SCOTTIE ADAMS
LOT 1
3801 E McKINNEY STREET
ANGEL & GRISELDA ENRIQUEZ
LOT 38
E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
LOT 29
C-06
LAT
45° FACTORY WYE
1+00.00 LAT C-05
8+46.06 LINE C=
END LAT C-05
F.L. 580.70
T.C. 585.20
CL 10' REC. INLET
PAV STA 105+00.00, 33.50' RT
1+11.34 LINE C=
END LAT C-09
F.L. 579.22
T.C. 583.72
CL 10' REC. INLET
PAV STA 106+65.00, 33.50' RT
1+11.29 LAT C-09=
END LAT C-11
F.L. 578.37
T.C. 582.87
CL 10' REC. INLET
PAV STA 107+65.00, 33.50' RT
1+11.29 LAT C-11=
45° FACTORY WYE
1+00.00 LAT C-09
6+78.57 LINE C=
45° FACTORY WYE
1+00.00 LAT C-11
5+77.02 LINE C=
236.77 LF 24" RCP 207.48 LF 36" RCP 55.75 LF 48" RCP
TO BE LOWERED
EX. 8" WATER
MATCHLINE LINE C STA 10+00MATCHLINE LINE C STA 5+00C-07
LAT END LAT C-06
CONNECT TO PROP. INLET
PAV STA 105+50.00, 39.00' LT
1+93.13 LAT C-06=
F.L. 579.54
TH 585.54
TOP 586.54
6'x6' SQUARE DROP INLET
PAV STA 105+50.00, 42.00' LT
BEGIN LAT C-06
BEGIN 24" RCP
END 36" RCP
RIM 584.00
CONSTRUCT 6'X6' SQUARE SDMH
PAV STA 105+89.45, 25.50' RT
1+00.00 LAT C-06
7+63.23 LINE C=
C-11
LAT
BEGIN LAT C-08
BEGIN 36" RCP
END 48" RCP
RIM 582.34
SQUARE SDMH
CONSTRUCT 6'X6'
25.50' RT
PAV STA 107+93.97,
1+00.00 LAT C-08
5+55.75 LINE C=
F.L. 578.21
TH 583.71
TOP 584.71
5'x5' SQUARE DROP INLET
PAV STA 107.30.00, 42.00' LT
END LAT C-08
CONNECT TO PROP. INLET
PAV STA 107.30.02, 39.50' LT
1+92.89 LAT C-08=C-10
LAT
F.L. 578.28
TH 583.28
TOP 584.28
4'x4' SQUARE DROP INLET
PAV STA 108+35.00, 42.00' LT
END LAT C-10
CONNECT TO PROP. INLET
40.00' LT
PAV STA 108+35.00,
1+92.63 LAT C-10=
BEGIN LAT C-07
45° FACTORY WYE
1+00.00 LAT C-07
1+59.06 LAT C-06=
END LAT C-07
F.L. 580.63
T.C. 585.13
CL 10' REC. INLET
PAV STA 105+50.00, 27.50' LT
1+11.78 LAT C-07=
CURVE 2 (CV C-2)
CV C-2
C-08
LAT
PULL RCP AT JOINTS
R = 1,662.17'
L = 328.93'
T = 165.01'
DEG = 3° 26' 49.37"
= 11° 20' 18.63" RT
E = 2401392.38
N = 7127392.62
PI STA = 7+35.00
PT CV C-2
5+69.99 LINE C
PC CV C-2
8+98.92 LINE C
STREETMcKINNEY
24"
R
CP
1"=40'H
1"=10'V
NOTES:CITY OF DENTON - McKINNEY STREET PHASE TWOINFORMATION.
PROFILE SHEETS FOR ADDITIONAL
SEE WATER AND WASTEWATER PLAN AND 3.
FOR ADDITIONAL INFORMATION.
2. SEE PAVING PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE DRAINAGE AREA MAP
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LINE-C_03.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LINE-C_03.dgn1:404:42:35 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
LINE C
STORM DRAIN PLAN & PROFILE
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
V
PARKING AREA
PARKING AREA
CONCRETE
E
E
PARKING AREA
PARKING AREA
PARKING AREA
PARKING AREA
S
S
D
D
S
STREET
4001 E McKINNEY
CITY OF DENTON
3922 E McKINNEY STREET
GOEL VENTURES ONE, LLC
3801 E McKINNEY STREET
ANGEL & GRISELDA ENRIQUEZ
3919/3921 E McKINNEY STREET
NSA PROPERTY HOLDINGS, LLC
3916 E McKINNEY STREET
EDWARD D & SHARYL K DIELEMAN
3918-3920 E McKINNEY STREET
LESLIE A & MICHAEL L ORINGDERFF
3923 E McKINNEY STREET
DENTON 3919 McKINNEY, LLC
LOT 3
LOT 5R1
LOT 152
LOT 38
LOT 4LOT 3
LOT 1R
CAB. Y, PG. 289
20' UTILITY EASEMENT
CAB. B, PG. 71
25' UTILITY EASEMENT
CAB. B, PG. 147
16' UTILITY EASEMENT
CAB. B, PG. 71
16' UTILITY EASEMENT
WV
8" WW
8" WW
8" W 8" W
6" W6" W
6" W 6" W
12" W
12" W12" W6" W 12" W
20" W20" W20" W
20" W
8" WW 8" WW 8" WW 10"
WW8" WW8" WW10" WW8" W12"
W15" RCP
18" RCP 18" RCP
18" RCP
2-18" RCP
27" RCP
BOX CULVERT6'x4'BOX CULVERT6'x4'BOX CULVERT6'x4'18"
RCPB
O
X
C
U
L
V
E
R
T
6'x4'
8" WW
(ABANDONED)10"
WW(
A
BAND
O
NE
D)
1
0" WW8" WW
PT 112+56.89 PC 111+52.17109+00 111+00 112+00 113+00
222+00223+00224+0012" W 12" W
20" W 20" W 20" W
12" W
12" W20" W
SLEEVES
6" PVC
SLEEVES
6" PVC
SLEEVES
6" PVC
SLEEVES6" PVC
SLEEVES6" PVC SLEEVES6" PVC
SLEEVES6" PVC 6" W24"D
1+002+003+0018"18"24" RCP18"18"
R
C
P BOX CULVERT6'x4'BOX CULVERT6'x4'RCP24" RCP24" 1+002+003+004+005+00 4'X4' RCBRCB
4'X4'
RCB
4'X4'
RCB
4'X4'
1+002+005+00 4+00 3+00FL 18"=575.36FL 18"=575.34FL 18"=575.20FL 18"=575.01FL 24"=574.86FL 24"=574.74FL 6'x4'=573.53FL 24"=575.25FL 24"=575.23FL 4'x4'=573.53FL 4'x4'=573.63FL 4'x4'=573.73FL 4'x4'=573.74FL 4'x4'=573.76FL 4'x4'=573.83FL 4'x4'=573.86FL 4'x4'=573.93FL 4'x4'=573.95FL 4'x4'=574.03FL 4'x4'=574.09FL 4'x4'=574.11FL 4'x4'=574.13FL 4'x4'=574.23FL 4'x4'=574.23FL 4'x4'=574.25FL 4'x4'=574.33LINE C
BY OTHERS
RELOCATED
CCTV TO BE
V=3.93 FPS
FT/FT
S=0.00119
C=81.79 CFS
Q100=62.87 CFS
V=4.32 FPS
S=0.00143 FT/FT
C=81.79 CFS
Q100=69.11 CFS
V=4.74 FPS
S=0.00172 FT/FT
C=81.79 CFS
Q100=75.84 CFS
V=4.79 FPS
S=0.00175 FT/FT
C=81.79 CFS
Q100=76.58 CFS
V=4.84 FPS
S=0.00179 FT/FT
C=81.79 CFS
Q100=77.47 CFS
V=5.23 FPS
S=0.00210 FT/FT
C=81.79 CFS
Q100=83.73 CFS
V=5.50 FPS
S=0.00232 FT/FT
C=81.79 CFS
Q100=88.08 CFS
V=5.59 FPS
S=0.00239 FT/FT
C=81.79 CFS
Q100=89.42 CFS
V=6.05 FPS
S=0.00280 FT/FT
C=81.79 CFS
Q100=96.74 CFS
AT PIPE CL
PR. GRADE
AT PIPE CL
EX. GROUND
HG 580.29HG 580.40HG 580.14HG 580.27HG 579.94HG 580.04HG 579.82HG 579.92HG 579.55HG 579.70HG 579.30HG 579.45HG 579.06HG 579.19HG 578.83HG 579.03 HG 578.53100 YEAR HGL
OTHERS
RELOCATED BY
EX. GAS TO BE
FL=572.15
(ABANDONED)
EX. 10" WWFL 570.82+/-
PROP. 6" WATER
4'X4' RCB ON 0.20%45° LAT. CONNECT.1+00.00 LAT C-152+63.32 LINE C =45° LAT. CONNECT.1+00.00 LAT C-172+05.82 LINE C =45° LAT. CONNECT.1+00.00 LAT C-182+16.72 LINE C =45° LAT. CONNECT.1+00.00 LAT C-163+11.49 LINE C =60° LAT. CONNECT.1+00.00 LAT C-133+89.58 LINE C =45° LAT. CONNECT.1+00.00 LAT C-143+77.92 LINE C =45° LAT. CONNECT.1+00.00 LAT C-104+49.23 LINE C=45° LAT. CONNECT.1+00.00 LAT C-124+61.72 LINE C=BEGIN LINE CTOP OF 6'x4' RCBCONSTRUCT MH ON1+98.29 LINE D1+00.00 LINE C=MATCHLINE LINE C STA 5+00MATCHLINE LINE C STA 5+00LINE C
LAT C-10
LAT C-13
LAT C-15 LAT C-17
LAT C-16 LAT C-18LAT C-14 N MAYHI
LL ROADS MAYHI
LL ROAD25.5'END LAT C-13
F.L. 579.41
TOP 583.91
W/2' RIP-RAP APRON
TWO-GRATE INLET
PAV STA 109+20.00, 45.50' LT
1+80.29 LAT C-13
STREET
McKINNEY
END LAT C-14
F.L. 577.38
T.C. 581.88
CL 5' STD. INLET
PAV STA 109+63.80, 33.50' RT
1+11.31 LAT C-14
END LAT C-15
F.L. 578.36
TOP 583.36
SIX-GRATE INLET
PAV STA 110+15.00, 47.50' LT
2+00.28 LAT C-15
END LAT C-16
F.L. 577.17
T.C. 581.67
CL 15' REC. INLET
PAV STA 110+30.00, 33.50' RT
1+11.48 LAT C-16
STREET
4001 E McKINNEY
CITY OF DENTON
LOT 152
END LAT C-18
F.L. 577.84
T.C. 582.34
CL 10' REC. INLET
PAV STA 111+25.00, 33.50' RT
1+11.31 LAT C-18
LINE D
END LAT C-17
F.L. 579.43
TOP 583.93
W/2' RIP-RAP APRON
SIX-GRATE INLET
PAV STA 110+75.00, 45.50' LT
1+97.45 LAT C-17
END LAT C-12
F.L. 577.80
T.C. 582.30
CL 20' REC. INLET
PAV STA 108+80.00, 33.50' RT
1+11.31 LAT C-12
400 LF 48" RCP
C-12
LAT
208
570
575
580
585
590
565
560
555555
560
565
570
575
580
585
590
REFERENCE ONLY
TO GRATE INLET.
FLUME TO DRAIN
GRADE. EXISTING
BELOW FINISHED
INLET SET 0.1'
TOP OF GRATE
SLEEVES
6" PVC
BEGIN LAT C-17
45° LATERAL CONNECTION
1+00.00 LAT C-17
2+05.82 LINE C =
BEGIN LAT C-18
45° LAT. CONNECT.
1+00.00 LAT C-18
2+16.72 LINE C =
BEGIN LAT C-15
45° LAT. CONNECT.
1+00.00 LAT C-15
2+63.32 LINE C =
BEGIN LAT C-16
45° LAT. CONNECT.
1+00.00 LAT C-16
3+11.49 LINE C =
BEGIN LAT C-13
60° LAT. CONNECT.
1+00.00 LAT C-13
3+89.58 LINE C =
BEGIN LAT C-14
45° LAT. CONNECT.
1+00.00 LAT C-14
3+77.92 LINE C =
BEGIN LAT C-10
45° LAT. CONNECT.
1+00.00 LAT C-10
4+49.23 LINE C =
BEGIN LAT C-12
45° LAT. CONNECT.
1+00.00 LAT C-12
4+61.72 LINE C =
BEGIN LINE C
RIM 583.20'
CONSTRUCT MH ON TOP OF 6'x4' RCB
PAV STA 112+49.89, 24.10' RT
1+98.29 LINE D
1+00.00 LINE C=
1"=40'H
1"=10'V
NOTES:CITY OF DENTON - McKINNEY STREET PHASE TWOINFORMATION.
PROFILE SHEETS FOR ADDITIONAL
SEE WATER AND WASTEWATER PLAN AND 3.
FOR ADDITIONAL INFORMATION.
2. SEE PAVING PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE DRAINAGE AREA MAP
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LINE-E.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LINE-E.dgn1:404:42:37 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
LINE E & LINE F
STORM DRAIN PLAN & PROFILE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
CONCRETE
CONCRETE
S
S
E McKINNEY STREET (200' STRIP)
BCI REAL ESTATE VENTURES, LP
STREET
4001 E McKINNEY
CITY OF DENTON
E McKINNEY STREET
CITY OF DENTON
4301 E McKINNEY STREET
CITY OF DENTON
LOT 153
LOT 151 (PT)
LOT 152 LOT 154
VOL. 5039, PG. 01970
DRAINAGE EASEMENT
20' PERMANENT
WV
12" W 20" W16" W
2
0" W20"
W16" W
20" W 12" W
12" W8" W 8" W 8" W
8" WW 8" WW8" WW
15" CMP
10'x4' RCBCPTZ PC 116+81.83113+00 114+00 115+00 116+00
16" W 16" W10" WW16" W
0+001+00SLEEVES6" PVC SLEEVES6" PVC BOX CULVERT5'x4'18" RCP18"18" RCP
5'X2' RCB 2+002+00
10+00D
10+00FL 5'x4'=576.99FL 5'x4'=577.33FL 5'x4'=577.04FL 5'x2'=577.04FL 18"=578.29X
5'x4'RCB ON 0.50%
AT PIPE CL
PR. GRADE
LINE F
BEGIN LINE FCULVERTFOR 5'x4' BOX CH-PW-0CONSTRUCT TXDOT 10+00.00 LINE FEND LINE FCULVERTFOR 5'x4' BOX CH-PW-0CONSTRUCT TXDOT 10+68.00 LINE FCONNECT LINE GCONNECT LINE E1+02.93 LINE G1+00.00 LINE E=10+11.50 LINE F=AT PIPE CL
EX. GRADE HG 580.27HG 579.53HG 579.49 PARTIAL FLOW
V=7.25 FPS
S=0.00350 FT/FT
C=173.42 CFS
Q100=145.01 CFS
PARTIAL FLOW
V=4.50 FPS
S=0.00135 FT/FT
C=173.42 CFS
Q100=89.95 CFSHG 580.66HG 580.341+002+00 FL 18"=578.29FL 18"=578.79FL 18"=579.29FL 18"=579.60FL 5'x4'=577.04FL 18"=579.50LINE E
BEGIN LINE EPROP. 5'x4' RCBCONNECT TO10+11.50 LINE F1+00.00 LINE E=SQUARE SDMHCONSTRUCT 4'X4'2+20.04 LINE E=END LINE E10' REC. INLET2+29.94 LINE E=CLASS III
18" RCP ON 1.00%
AT PIPE CL
PR. GRADE
AT PIPE CL
EX. GROUND HG 579.53HG 580.26FLOW
PARTIAL 100 YEAR HGL
PARTIAL FLOW
V=1.41 FPS
S=0.00056 FT/FT
C=10.52 CFS
Q100=2.49 CFS
FL=572.32
W/ 18" ENCASEMENT
PROP. 10" WW
LINE G
McKINNEY STREET
25.5'LINE E
LINE F
REFERENCE ONLY
209S MAYHI
LL ROADBEGIN LINE E
CONNECT TO LINE F
PAV STA 115+26.63, 25.50' RT
1+02.93 LINE G=
10+11.50 LINE F=
1+00.00 LINE E=
RIM 583.75
CONSTRUCT 4'X4' SQUARE SDMH
PAV STA 114+06.00, 25.50' RT
STA 2+20.04 LINE E
229.94 LF 18" RCP
68 LF 5'x4' RCB 575
580
585
590
595
570
565560
565
570
575
580
585
590
595 600
575
580
585
590
595
570
565
600
560
565
570
575
580
585
590
595
END LINE E
F.L. 579.60
T.C. 584.10
CL 10' REC. INLET
PAV STA 114+00.00, 33.50' RT
2+29.94 LINE E
SLEEVES6" PVC
SLEEVES
6" PVC
BEGIN LINE F
30 SY TYPE R STONE RIPRAP
FOR 5'x4' BOX CULVERT
CONSTRUCT TXDOT CH-PW-0
PAV STA 115+26.63, 37.00' RT
10+00.00 LINE F
END LINE F
47 SY TYPE R STONE RIPRAP
FOR 5'x4' BOX CULVERT
CONSTRUCT TXDOT CH-PW-0
PAV STA 115+26.63, 31.00' LT
10+68.00 LINE F
1"=40'H
1"=10'V
NOTES:CITY OF DENTON - McKINNEY STREET PHASE TWOINFORMATION.
PROFILE SHEETS FOR ADDITIONAL
SEE WATER AND WASTEWATER PLAN AND 3.
FOR ADDITIONAL INFORMATION.
2. SEE PAVING PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE DRAINAGE AREA MAP
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LINE-G_01.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LINE-G_01.dgn1:404:42:40 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
LINE G
STORM DRAIN PLAN & PROFILE
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
CONCRETE
CONCRETE
S
S
E McKINNEY STREET (200' STRIP)
BCI REAL ESTATE VENTURES, LP
STREET
4001 E McKINNEY
CITY OF DENTON
E McKINNEY STREET
CITY OF DENTON
4301 E McKINNEY STREET
CITY OF DENTON
4393 E McKINNEY STREET
KENNETH L & GLADYS F STOUT
LOT 153
LOT 151 (PT)
LOT 159LOT 154
VOL. 5039, PG. 01970
DRAINAGE EASEMENT
20' PERMANENT
BAYLOR UNIVERSITY
LOT 151 (PT)
WV
12" W 20" W16" W
2
0" W16" W 16" W
20" W 12" W
12" W8" W 8" W 8" W 8" W
8" WW 8" WW8" WW 8" WW
15" CMP 15" CMP
10'x4' RCBCPTZ PC 116+81.83114+00 115+00 116+00 117+00 118+00
16" W 16" W10" WW16" W 16" W 16" WSLEEVES6" PVC SLEEVES6" PVC BOX CULVERT5'x4'18" RCP18"18" RCP 18"5'X2' RCB5'X2' RCB 5'X2' RCB
18" RCPRCP
24"
2+00 3+00
4+002+00
10+00D
1+00 2+00 3+00 4+00 FL 5'x2'=578.37FL 5'x2'=578.11FL 5'x2'=577.85FL 5'x2'=577.59FL 5'x2'=577.33FL 5'x2'=577.23FL 5'x2'=577.13FL 5'x4'=577.04FL 5'x2'=577.38FL 18"=577.63FL 18"=577.83FL 5'x2'=577.58FL 5'x2'=577.04LINE G
5'x2' RCB ON 0.52%
5'x2' RCB ON 0.20%CONNECTION45° LATERAL1+00.00 LAT G-012+98.20 LINE G =BEGIN LINE GPROP. 5'x4' RCBCONNECT TO10+11.50 LINE F1+02.93 LINE G=PVI2+50.00 LINE G=CONNECTION45° LATERAL TOP OF 5'X2' RCBCONSTRUCT MH ON1+00.00 LAT G-022+58.55 LINE G=Q100=54.14 CFS
C=65.68 CFS
S=0.00351 FT/FT
V=5.41 FPS
Q100=58.09 CFS
C=65.68 CFS
S=0.00405 FT/FT
V=5.81 FPS
Q100=60.42 CFS
C=40.85 CFS
S=0.00438 FT/FT
V=6.04 FPS
AT PIPE CL
PR. GRADE
AT PIPE CL
EX. GROUND
HG 580.27HG 579.53HG 581.35HG 581.05HG 581.70HG 581.51HG 581.01HG 580.91100 YEAR HGL
Q100=60.42 CFS
C=65.68 CFS
S=0.00438 FT/FT
V=6.04 FPS MATCHLINE LINE G STA 4+50MATCHLINE LINE G STA 4+50210
LAT G-02
LAT G-01
LINE G
McKINNEY STREET
25.5'LINE E
LINE F
REFERENCE ONLY
END LAT G-02
F.L. 579.03
T.C. 583.53
CL 10' REC. INLET
PAV STA 117+35.00, 27.50' LT
1+74.78 LAT G-02
END LAT G-01
F.L. 578.60
T.C. 583.10
CL 15' REC. INLET
PAV STA 117+30.00, 33.50' RT
1+11.30 LAT G-01
BEGIN LAT G-01
45° LATERAL CONNECTION
1+00.00 LAT G-01
2+98.20 LINE G =
575
580
585
590
595
570
565
560
575
580
585
590
595
570
565
560
BEGIN LINE G
90° CONNECTION TO LINE F
PAV STA 115+26.63, 25.50' RT
1+00.00 LINE E
10+11.50 LINE F=
1+02.93 LINE G=
347.07 LF 5'X2' RCB
CURVE 1 (CV G-1)
PC CV G-1
2+58.13 LINE G
CV G-1
PULL RCP AT JOINTS
R = 11,435.66'
L = 311.81'
T = 305.98'
DEG = 0° 30' 03.70"
= 3° 03' 55.13" RT
E = 2402428.10
N = 7127137.01
PI STA = 5+64.11
BEGIN LAT G-02
RIM 582.87
ON TOP OF 5'X2' RCB
CONSTRUCT MANHOLE
PAV STA 116+82.25, 25.50' RT
1+00.00 LAT G-02
2+58.55 LINE G=
1"=40'H
1"=10'V
NOTES:CITY OF DENTON - McKINNEY STREET PHASE TWOINFORMATION.
PROFILE SHEETS FOR ADDITIONAL
SEE WATER AND WASTEWATER PLAN AND 3.
FOR ADDITIONAL INFORMATION.
2. SEE PAVING PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE DRAINAGE AREA MAP
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LINE-G_02.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LINE-G_02.dgn1:404:42:42 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
LINE G
STORM DRAIN PLAN & PROFILE
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
PARKING AREA
PBX
PBX
DBL. 18" ELM
15" PECAN
TRI 12" PECAN
30" PECAN
DBL. 8" TREEDBL. 8"/15" TREE
S
BAYLOR UNIVERSITY
4515 E McKINNEY STREET
KENNETH L & GLADYS F STOUT
4663 E McKINNEY STREET
MEMORIAL BAPTIST CHURCH OF DENTON
4673 E McKINNEY STREET
MEMORIAL BAPTIST CHURCH OF DENTON
LOT 151 (PT)
LOT 161 LOT 162, 163, 164 (OLD DCAD 1P, 1P2, 1R), AC
LOT 166
DOC # 99-R0026679
EASEMENT
20' PUBLIC UTILITY
VOL. 5039, PG. 01056
EASEMENTCONSTRUCTION
20' TEMPORARY
VOL. 5039, PG. 01056
EASEMENT
20' PUBLIC UTILITY
VOL. 5039, PG. 01056
EASEMENT
8' PUBLIC UTILITY
WV
WV
FM
16" W 16" W
16" W
8" W
8" W 8" W8" WW
8" WW
8" WW 8" WW
15" CMP 15" CMP 18" CMP
16" W
119+00 120+00 121+00 122+00 123+00
16" W 16" W 16" W16" W
SLEEVES6" PVC 6" PVC SLEEVES 6" PVC SLEEVES
5'X2' RCB 5'X2' RCB
24" RCP 24" RCP5'X2' RCB18"36" RCP5+00 6+00 7+00 8+00 9+00RCB
5'X3'
CLASS III36" RCP ON 0.52%
5'x2' RCB ON 0.52%
BOP 577.96 ±
LINE G
CONNECTION45° LATERAL1+00 LAT G-045+52.62 LINE G=CONNECTION45° LATERAL1+00 LAT G-066+62.16 LINE G=Q100=54.14 CFS
C=65.68 CFS
S=0.00351 FT/FT
V=5.41 FPS
Q100=45.36 CFS
C=65.68 CFS
S=0.00247 FT/FT
V=4.54 FPS
Q100=41.83 CFS
C=65.68 CFS
S=0.00210 FT/FT
V=4.18 FPS
Q100=29.97 CFS
C=65.68 CFS
S=0.00108 FT/FT
V=3.00 FPS
Q100=29.97 CFS
C=47.94 CFS
S=0.00202 FT/FT
V=4.24 FPS
45° FACTORY WYE1+00 LAT G-035+07.99 LINE G=RELOCATED BY OTHERS
& FIBER TO BE
CTV, GAS,5'X3' RCB5'X2' RCB TOTRANSITION FROM8+58.77 LINE GON 0.52%
5'X3' RCB BEGIN 36" RCPEND 5'X3' RCB8+72.94 LINE GEND LINE GEND 36" RCPDROP INLETCONSTRUCT 6'X6'9+52.94 LINE GTOP OF 5'X3' RCBCONSTRUCT MH ON8+69.94 LINE GAT PIPE CL
EX. GROUND AT PIPE CL
PR. GRADE HG 582.65HG 582.43HG 582.88HG 582.76HG 583.27HG 583.11 STANDARD DETAILS
CITY OF DENTON
ACCORDING TO
BE LOWERED
EX. 8" WATER TO
100 YEAR HGL
FLOW
PARTIAL
5+00 6+00 7+00 8+00 9+00FL 36"=580.70FL 5'x2'=580.18FL 5'x2'=579.92FL 5'x2'=579.66FL 5'x2'=579.40FL 5'x2'=579.14FL 5'x2'=578.89FL 5'x2'=578.63FL 5'x2'=578.37FL 36"= 580.97FL 24"= 579.47FL 5'X2'=579.47FL 5'X2'=580.44FL 18"= 579.15FL 5'X2'=578.90FL 24"= 578.67FL 5'X2'=578.67FL 36"=580.95FL 5'X2'=580.48FL 5'X3'=580.48FL 5'X2'=580.56FL 5'X3'=580.56211
LAT G-06LAT G-03
LINE G
LINE G
MATCHLINE LINE G STA 4+50MATCHLINE LINE G STA 4+00MATCHLINE LINE G STA 4+50408.77 LF 5'X2' RCB
END LAT G-06
F.L. 581.19
T.C. 586.19
CL 20' REC. INLET
PAV STA 121+40.00, 27.50' LT
1+75.13 LAT G-06=
END LAT G-04
F.L. 580.45
T.C. 584.95
CL 10' REC. INLET
PAV STA 119+85.00, 33.50' RT
1+11.32 LAT G-04=
575
580
585
590
595
570
565
560 560
565
570
575
580
585
590
595
45° LATERAL CONNECTION
1+00.00 LAT G-06
6+62.16 LINE G=
45° LATERAL CONNECTION
1+00.00 LAT G-03
5+07.99 LINE G=
45° LATERAL CONNECTION
1+00.00 LAT G-04
5+52.62 LINE G=
LAT G-04
TO BE LOWERED
EX. 8" WATER
25.5'PLUG 5'X3' RCB
BEGIN 36" RCP
END 5'X3' RCB
5'X3' RCB
90° CONNECTION TO
8+72.94 LINE G=
TO 5'X3' RCB
TRANSITION FROM 5'X2' RCB
8+58.77 LINE G
80 LF 36" RCPRCB*
5'X3'
16 LF
TO PLUG
*MEASURED
CONTRACT
OTHERS, BEGIN WORK THIS
END WORK TO BE DONE BY
INLET LOCATION BY OTHERS
INSTALLED AND PLUGGED AT
STA 119+50 LAT G-03 TO BE
END LAT G-03
F.L. 579.95
T.C. 584.95
CL 20' REC. INLET
PAV STA 119+85.00, 27.50' LT
1+74.78 LAT G-03=
F.L. 580.97
TH 587.47
TOP 588.47
4'x4' SQUARE DROP INLET
59.50' LT
PAV STA 122+95.00,
END LINE G
CONNECT TO PROP. INLET
57.50' LT
PAV STA 122+95.00,
9+52.94 LINE G
PT CV G-1
RIM 586.77'
PAV STA 122+95.00, 25.50' RT
ON TOP OF 5'X3' RCB
CONSTRUCT MANHOLE
8+69.94 LINE G=
CURVE 1 (CV G-1)
PULL RCP AT JOINTS
R = 11,435.66'
L = 311.81'
T = 305.98'
DEG = 0° 30' 03.70"
= 3° 03' 55.13" RT
E = 2402428.10
N = 7127137.01
PI STA = 5+64.11
CV G-1
STREETMcKINNEY
1"=40'H
1"=10'V
NOTES:CITY OF DENTON - McKINNEY STREET PHASE TWOINFORMATION.
PROFILE SHEETS FOR ADDITIONAL
SEE WATER AND WASTEWATER PLAN AND 3.
FOR ADDITIONAL INFORMATION.
2. SEE PAVING PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE DRAINAGE AREA MAP
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LINE-H_01.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LINE-H_01.dgn1:404:42:45 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
LINE H
STORM DRAIN PLAN & PROFILE
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PBX
36" TREE
36" PECAN
2" TREE
36" PECAN
2" TREE
48" PECAN
DBL. 4"/15" HACKBERRY
6" HACKBERRY
21" CEDARDBL. 15"/24" PECAN
S
BCI REAL ESTATE VENTURES,LP
5001 E McKINNEY STREET
BARBARA McDONALD COBB
5043 E McKINNEY STREET
CHELA DARLINE McDONALD
LOT 151 (PT)
LOT 168
LOT 169
VOL. 5039, PG. 01056
EASEMENT
8' PUBLIC UTILITY DOC
# 99-R0
0
7
7
3
0
9
2
0' PUBLI
C UTI
LI
TY EAS
EMENTVOL. 5039, PG. 01056
EASEMENTCONSTRUCTION
20' TEMPORARY
FM
16" W 16" W
8" WW 8"
WW6" W
6
" W6
" W8" W
15" RCP
15" RCP
21" RCP 21" RCP 21" RCP
PC 129+61.61126+00 127+00 128+00 129+00 130+00
16" W 16" W 16" W 16" W 16" W
SLEEVES
6" PVC
SLEEVES
6" PVC
SLEEVES
6" PVC
SLEEVES
6" PVC
SLEEVES
6" PVC
D
7+00 4+005+006+00
18" RCP18" RCP36"
R
C
P
18" RCP
36" RCP
36" RCP18"18" RCPD
36" RCP
RCP
24"
4'x3' RCB
END LINE H10' REC. INLET7+43.07 LINE H60°FACTORY WYE1+00.00 LAT H-015+97.91 LINE H=45°FACTORY WYE1+00.00 LAT H-026+71.02 LINE H=LINE H
V=4.75 FPS
S=0.00254 FT/FT
C=44.23 CFS
Q100=33.60 CFS
V=3.04 FPS
S=0.00087 FT/FT
C=92.29 CFS
Q100=36.47 CFS
CLASS III
PROP. 36" RCP ON 0.44%
V=3.80 FPS
S=0.00163 FT/FT
C=44.23 CFS
Q100=26.88 CFS
45°FACTORY WYE1+00.00 LAT H-055+33.58 LINE H=CLASS III
ON 0.44%
PROP. 36" RCP BEGIN 18" RCPEND 36" RCPSQUARE SDMHCONSTRUCT 4'X4'7+33.17 LINE H=4.75%
18" RCP ON
PROP. CLASS III
V=1.41 FPS
S=0.00056 FT/FT
C=22.89 CFS
Q100=2.49 CFS
V=0.35 FPS
S=0.00001 FT/FT
C=44.23 CFS
Q100=2.49 CFS
V=0.68 FPS
S=0.00005 FT/FT
C=44.23 CFS
Q100=4.84 CFS
AT PIPE CL
EX. GROUND
AT PIPE CL
PR. GRADE BEGIN 36" RCPEND 4'X3' RCBSQUARE SDMHCONSTRUCT 6'X6'1+00.00 LAT H-044+78.89 LINE H=RCB ON 0.56%
PROP. 4'X3' CONNECTION45°LATERAL1+00.00 LAT H-064+03.32 LINE H=HG 585.21HG 585.31HG 585.10HG 585.20HG 585.00HG 585.10HG 584.78HG 585.00HG 584.49HG 584.67HG 584.25HG 584.35HG 584.09HG 584.19100 YEAR HGL
4+005+006+007+00FL 18"= 582.67FL 36"= 580.55FL 36"= 580.33FL 36"= 580.11FL 36"= 579.89FL 36"= 579.67FL 36"= 580.10FL 36"= 580.10FL 36"= 580.42FL 18"= 581.17FL 36"= 579.82FL 18"= 580.57FL 36"= 580.70FL 18"= 582.20FL 4'X3'= 579.14FL 4'X3'= 579.42FL 4'X3'= 579.58FL 18"= 580.33FL 36"= 579.58FL 4'X3'= 579.16FL 18"= 579.91585
580
570
565
575
590
595MATCHLINE LINE H STA 4+00MATCHLINE LINE H STA 4+00585
580
570
565
575
590
595
LAT H-06
EX. R.O.W
EX. R.O.W
LINE H
212
STREET
McKINNEY
VOL. 5039, PG. 01056
EASEMENT
8' PUBLIC UTILITY
DOC # 99-R0077309
20' PUBLIC UTILITY EASEMENT
ROADCARPENTER
5043 E McKINNEY STREET
CHELA DARLINE McDONALD
LOT 169
LAT H-04LAT H-05LAT H-01LAT H-02
25.5'BEGIN LAT H-01
60° FACTORY WYE
1+00.00 LAT H-01
5+97.91 LINE H =
END LINE H
F.L. 582.67
T.C. 587.17
CL 10' REC. INLET
PAV STA 126+54.63, 33.50' RT
STA 7+43.07 LINE H =
BEGIN LAT H-02
45° FACTORY WYE
1+00.00 LAT H-02
6+71.02 LINE H =
END LAT H-02
F.L. 582.67
T.C. 587.17
CL 10' REC. INLET
PAV STA 126+70.37, 27.50' LT
1+74.95 LAT H-02 =
END LAT H-04
F.L. 581.67
T.C. 586.67
CL 10' REC. INLET
PAV STA 128+65.00, 27.50' LT
1+74.95 LAT H-04 =
END LAT H-06
F.L. 581.80
T.C. 586.30
CL 10' REC. INLET
27.50' LT
PAV STA 129+38.50,
1+74.70 LAT H-06 =
254.28 LF 36" RCP
LINE H BEGIN LAT H-05
45° FACTORY WYE
1+00.00 LAT H-05
5+33.58 LINE H=
INSTALL 22.5° BEND
1+09.69 LAT H-05
INSTALL 22.5° BEND
1+20.03 LAT H-05
F.L. 580.36
T.H. 586.36
TOP 587.36
CONSTRUCT 5'X5' DROP INLET
PAV STA 127+50.00, 57.50' LT
F.L. 580.94
T.H. 585.94
TOP 586.94
CONSTRUCT 2'X2' DROP INLET
PAV STA 128+50.00, 35.50' LT
END LAT H-01
CONNECT TO PROP. INLET
PAV STA 127+50.00, 55.00' LT
1+92.96 LAT H-01=
END LAT H-05
CONNECT TO PROP. INLET
PAV STA 128+50.00, 34.50' LT
1+63.63 LAT H-05 =
BEGIN 18" RCP
END 36" RCP
RIM 586.78
CONSTRUCT 4'X4' SQUARE SDMH
PAV STA 126+60.63, 25.50' RT
STA 7+33.17 LINE H
9.90 LF 18" RCP
BEGIN LAT H-06
45° LATERAL CONNECTION
1+00.00 LAT H-06
4+03.32 LINE H =
BEGIN LAT H-04
BEGIN 36" RCP
END 4'X3' RCB
RIM 586.02
CONSTRUCT 6'X6' SQUARE SDMH
PAV STA 129+15.50, 25.50' RT
1+00.00 LAT H-04=
4+78.89 LINE H =
78.89 LF 4'X3' RCB
600600
CURVE 1 (CV H-1)
PULL RCP AT JOINTS
R = 6,224.50'
L = 332.78'
T = 166.43'
DEG = 0° 55' 13.76"
= 3° 03' 47.57" LT
E = 2403807.22
N = 7126709.39
PI STA = 2+66.43
CV H-1
PC CV H-1
4+32.78 LINE H
1"=40'H
1"=10'V
NOTES:CITY OF DENTON - McKINNEY STREET PHASE TWOINFORMATION.
PROFILE SHEETS FOR ADDITIONAL
SEE WATER AND WASTEWATER PLAN AND 3.
FOR ADDITIONAL INFORMATION.
2. SEE PAVING PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE DRAINAGE AREA MAP
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LINE-H_02.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LINE-H_02.dgn1:404:42:47 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
LINE H
STORM DRAIN PLAN & PROFILE
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
CONCRETE
PBX
E
36" TREE
5101 E McKINNEY STREET
DENTON ISD
5090 E McKINNEY STREET
EDIBERTO A RODRIGUEZ E McKINNEY STREET
KIM Y PHAM
LOT 1R4
LOT 150
LOT 1
CAB. H, PG. 62
20' UTILITY EASEMENT
CAB. E, PG. 330
4' SIDEWALK EASEMENT
BCI REAL ESTATE VENTURES,LP
LOT 151 (PT)
WV
WV
WVFM16" W 16" W
16" W
8" W
8" W
8" W 10" W
10" W
24" RCP
27" RCP
15"
R
C
P
24"
R
C
P
27" RCP 27" RCP
2-48" RCP24" R
CPRCBCEX.9'X6'
130+00
131+00 132+00 133+00 134+00 135+00
16" W 16" W
16" W 16" W 16" W
1
0
" W6" PVC SLEEVES
6" PVC SLEEVES BOX CULVERT3-6'x3'D
1+002+00
3+00
4+00
2+00 3+00
18"
30" RCP 24" RCP18"18" RCP36" RCP36" RCP36" RCP24" RCP24"24"18"RCB
5'X3'18" RCP10+004'X3' RCB
4'X3' RCB
LINE H
ON 0.56%
PROP. 5'X3' RCB
V=3.24 FPS
S=0.00099 FT/FT
C=92.29 CFS
Q100=38.92 CFS
V=3.46 FPS
S=0.00112 FT/FT
C=92.29 CFS
Q100=41.50 CFS
V=4.05 FPS
S=0.00154 FT/FT
C=92.29 CFS
Q100=48.56 CFS
AT PIPE CL
EX. GROUND
AT PIPE CL
PR. GRADE 4'X3' RCB5'X3' RCB TO TRANSITION FROM1+93.06 LINE HCONNECTION45° LATERAL 1+00.00 LAT H-101+84.47 LINE H=CONNECTION45° LATERAL 1+00.00 LAT H-121+82.37 LINE H=RCB ON 0.56%
PROP. 4'X3' CONNECTION45°LATERAL1+00.00 LAT H-083+36.74 LINE H=CONNECTION45°LATERAL1+00.00 LAT H-072+89.39 LINE H=V=4.56 FPS
S=0.00174 FT/FT
C=122.47 CFS
Q100=68.45 CFS
HG 584.09HG 584.19HG 583.92HG 584.02HG 583.75HG 583.87HG 583.47HG 583.60HG 582.38HG 583.31BEGIN LINE H6'x3' RCBCONNECT TO10+11.51 LINE I1+00.00 LINE H=100 YEAR HGL BY OTHERS
RELOCATED
TO BE
EX. GAS
BY OTHERS
TO BE RELOCATED
EX. FIBER
1+002+003+004+00 FL 5'X3'= 577.75FL 6'X3'= 577.47FL 5'X3'= 577.47FL 36"= 577.94FL 5'X3'= 577.94FL 5'X3'= 577.93FL 18"= 578.68FL 4'X3'= 578.03FL 4'X3'= 578.31FL 4'X3'= 578.58FL 4'X3'= 578.86FL 4'X3'= 579.14FL 4'X3'= 578.79FL 18"= 579.54FL 4'X3'= 578.53FL 24"= 579.03X
X
LINE I
PR. GRADE
AT PIPE CLBEGIN LINE IBOX CULVERTSW-0 FOR 3-6'x3'CONSTRUCT TXDOT10+00.00 LINE I4'x3'RCBCONNECT TO1+00.00 LINE H10+11.51 LINE I=30" RCPCONNECT TO1+00.00 LINE J10+11.48 LINE I=END LINE IBOX CULVERT3-6'x3'CH-PW-0 FORCONSTRUCT TXDOT10+68.00 LINE ION 0.88%3-6'x3'RCB
V=8.41 FPS
S=0.00541 FT/FT
C=193.01 CFS
Q100=151.35 CFS
V=6.57 FPS
S=0.00331 FT/FT
C=193.01 CFS
Q100=118.33 CFS18" RCPCONNECT TO 45°FACTORY WYE1+00.00 LAT I-0210+40.27 LINE I=EX. GROUND
AT PIPE CL
V=6.69 FPS
S=0.00342 FT/FT
C=193.01 CFS
=120.41 CFS
Q100 (PER BOX)HG 582.38HG 582.38HG 582.67HG 582.48HG 582.96HG 582.76HG 582.32 100 YEAR HGL
BY OTHERS
TO BE RELOCATED
EX. FIBER
BY OTHERS
TO BE RELOCATED
EX. CCTV
FL 3-6'x3'=577.97FL 30"=577.66FL 3-6'x3'=577.39FL 3-6'x3'=577.47FL 4'x3'=577.47FL 3-6'x3'=577.72FL 18"=578.2610+00 11+00FL 3-6'x3'=577.37EX. R.O.WMATCHLINE LINE H STA 4+00EX. R.O.W
McKINNEY STREET
MATCHLINE LINE H STA 4+00213
LINE I
LAT I-02
LAT H-08
LINE J
END LINE I
84 SY TYP R STONE RIPRAP
FOR 3-6'x3' BOX CULVERT
CONSTRUCT TXDOT CH-PW-0
PAV STA 133+03.37, 31.00' LT
10+68.00 LINE I
H-07
LAT END LAT H-07
F.L. 580.74
T.C. 585.74
CL 10' REC. INLET
27.50' LT
PAV STA 130+50.00,
1+74.65 LAT H-07 =
END LAT H-08
F.L. 581.24
T.C. 585.74
CL 10' REC. INLET
PAV STA 130+50.00, 33.50' RT
1+11.32 LAT H-08 =
END LAT H-12
F.L. 580.46
T.C. 584.96
CL 10' REC. INLET
PAV STA 132+05.00, 33.50' RT
1+08.11 LAT H-12=
BEGIN LINE I
58 SY TYP R STONE RIPRAP
FOR 3-6'x3' BOX CULVERT
CONSTRUCT TXDOT SW-0
PAV STA 133+03.47, 37.00' RT
10+00.00 LINE I
END LAT I-02
F.L. 579.94
T.C. 584.44
CL 15' REC. INLET
PAV STA 133+37.50, 27.50' LT
1+34.08 LAT I-02
BEGIN LAT H-11
45°FACTORY WYE
1+00.00 LAT H-11
1+42.90 LAT H-10 =
BEGIN LAT H-09
45°FACTORY WYE
1+00.00 LAT H-09
1+50.64 LAT H-07 =25.5'93.06 LF 5'x3' RCB 68 LF 3-6'x3' RCB
575
570
565
580
585
590
595
565
570
575
580
585
590
595
END LAT H-11
CONNECT TO PROP. INLET
PAV STA 131+80.96, 74.77' LT
1+69.86 LAT H-11
END LAT H-09
PROP. INLET
CONNECT TO
40.00' LT
PAV STA 130+70.00,
1+29.59 LAT H-09,
H-09LAT
H-10
LAT
F.L. 580.81
TOP 586.81, TH 585.81
DROP INLET
CONSTRUCT 4'X4'
42.00' LT
PAV STA 130+70.00,
H-12
LAT
F.L. 579.40
T.C. 585.40
CL STD. 15' INLET
83.64' LT
PAV STA 131+08.64,
END LAT H-10
79.08' LT
131+08.50,
PAV STA
2+46.70 LAT H-10
LOWERED
TO BE
WATER
EX. 8"
LOWERED
TO BE
WATER
EX. 8"
RCP AND PLUG
STUB OUT 28 LF 24"
2+06.26 LAT H-07
BEGIN LAT H-08
45° LATERAL CONNECTION
1+00.00 LAT H-08
3+36.74 LINE H =
BEGIN LAT H-07
45° LATERAL CONNECTION
1+00.00 LAT H-07
2+89.39 LINE H =WAYRYAN HLINE
BEGIN LAT H-10
45° LATERAL CONNECTION
1+00.00 LAT H-10
1+84.47 LINE H =
BEGIN LAT H-12
45° LATERAL CONNECTION
1+00.00 LAT H-12
1+82.37 LINE H =
F.L. 578.52
T.C. 584.52
CL STD. NCTCOG 15' INLET, 5' WIDTH
PAV STA 131+78.94, 82.41' LT
4'X3' RCB TO 5'X3' RCB
TRANSITION FROM
1+93.06 LINE H
206.94 LF 4'X3' RCB
600
575
570
565
580
585
590
595
600 600
CURVE 1 (CV H-1)
PULL RCP AT JOINTS
R = 6,224.50'
L = 332.78'
T = 166.43'
DEG = 0° 55' 13.76"
= 3° 03' 47.57" LT
E = 2403807.22
N = 7126709.39
PI STA = 2+66.43
CV H-1
PT CV H-1
BEGIN LINE H
CONNECT TO 3-6'x3' BOX CULVERT
PAV STA 132+95.76, 25.50' RT
10+11.51 LINE I
1+00.00 LINE H =
LAT H-11
BEGIN LAT I-02
CONNECT TO 3-6'x3' BOX CULVERT
PAV STA 133+11.07, 3.29' LT
10+40.27 LINE I
1+00.00 LINE H =
1"=40'H
1"=10'V
NOTES:CITY OF DENTON - McKINNEY STREET PHASE TWOINFORMATION.
PROFILE SHEETS FOR ADDITIONAL
SEE WATER AND WASTEWATER PLAN AND 3.
FOR ADDITIONAL INFORMATION.
2. SEE PAVING PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE DRAINAGE AREA MAP
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LINE-J_01.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LINE-J_01.dgn1:404:42:50 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
LINE J
STORM DRAIN PLAN & PROFILE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
CONCRETEE
5101 E McKINNEY STREET
DENTON ISD
5090 E McKINNEY STREET
EDIBERTO A RODRIGUEZ E McKINNEY STREET
KIM Y PHAM
LOT 1R4
LOT 150
CAB. H, PG. 62
20' UTILITY EASEMENT
CAB. E, PG. 330
4' SIDEWALK EASEMENT
WV
WV
FM16" W
16" W
8" W
8" W 10" W
10" W
10" W
16" W
27" RCP
24"
R
C
P
27" RCP 27" RCP
2-48" RCP24" R
CP24" RCP
RCBCEX.9'X6'
132+00 133+00 134+00 135+00
136+00
16" W 16" W 16" W
16" W
1
0
" W6" PVC SLEEVES
6" PVC SLEEVES
6" PVC SLEEVES
BOX CULVERT3-6'x3'D
1+002+00 2+00 3+00
4+00
30" RCP 24" RCP18"18" RCP36" RCP36" RCP36" RCP 18"RCB
5'X3'18" RCP10+004'X3' RCB
CLASS III30" RCP ON 0.87%
CLASS III24" RCP ON 0.88%45° FACTORY WYE1+00.00 LAT J-022+33.98 LINE J=LINE J
45° FACTORY WYE1+00.00 LAT J-034+38.65 LINE J=45° FACTORY WYE1+00.00 LAT J-001+19.47 LINE J=BEGIN LINE J3-6'x3' RCBCONNECT TO10+11.48 LINE I1+03.72 LINE J=V=3.89 FPS
S=0.00217 FT/FT
C=38.46 CFS
Q100=19.08 CFSV=4.90 FPS
S=0.00345 FT/FT
C=38.13 CFS
Q100=24.06 CFS
V=5.51 FPS
S=0.00436 FT/FT
C=38.13 CFS
Q100=27.05 CFS
V=4.58 FPS
S=0.00407 FT/FT
C=21.21 CFS
Q100=14.40 CFSBEGIN 24" RCPEND 30" RCPSQUARE SDMHCONSTRUCT 4'x4'1+00 LAT J-012+62.66 LINE J=V=3.38 FPS
S=0.00222 FT/FT
C=21.21 CFS
Q100=10.63 CFS
AT PIPE CL
EX. GROUND
AT PIPE CL
PR. GRADE HG 583.31HG 582.38HG 583.57HG 583.38HG 584.16HG 583.97HG 584.32HG 584.22HG 585.23HG 585.04100 YEAR HGL
3+00 4+002+001+00 FL 30"=577.66FL 30"=578.06FL 30"=578.50FL 24"=579.43FL 24"=579.87FL 24"=580.31FL 24"=580.75FL 24"=581.19FL 24"=581.09FL 30"=579.04FL 30"=578.79FL 18"=579.29FL 18"=581.34FL 18"=578.30FL 30"=577.80FL 6'x3'=577.39FL 24"=579.54FL 18"=579.79585
580
570
565
575
590
595
600
McKINNEY STREET
EX. R.O.W
585
580
570
565
575
590
595
600MATCHLINE LINE J STA 4+50MATCHLINE LINE J STA 4+50RYAN WAYLAT J-02
LAT J-03
18" RCP
EX. R.O.W
214
LAT J-01
25.5'LOT 1
E McKINNEY STREET
KIM Y PHAM
LAT J-00
END LAT J-00
F.L. 579.94
T.C. 584.44
CL 10' REC. INLET
PAV STA 133+35.00, 33.50' RT
1+11.31 LAT J-00
END LAT J-01
F.L. 581.93
T.C. 586.43
CL 10' REC. INLET
PAV STA 135+00.00, 27.50' LT
1+60.80 LAT J-01
LINE H
LINE I
158.94 LF 30" RCP 187.34 LF 24" RCP
BEGIN 24" RCP
END 30" RCP
2+39.88 LINE J
LINE J
BEGIN LAT J-01
BEGIN 24" RCP
END 30" RCP
RIM 585.52
CONSTRUCT 4'x4' SQUARE SDMH
PAV STA 134+70.74, 25.50' RT
1+00.00 LAT J-01
2+62.66 LINE J=
BEGIN LAT J-03
45° FACTORY WYE
PAV STA 136+47.63, 25.50' RT
1+00.00 LAT J-03
4+38.65 LINE J =
END LAT J-02
F.L. 581.05
T.C. 585.55
CL 10' REC. INLET
PAV STA 134+50.00, 33.50' RT
1+11.32 LAT J-02
BEGIN LAT J-00
45° FACTORY WYE
PAV STA 133+26.97, 25.50' RT
1+19.47 LINE J
1+00.00 LAT J-00=
BEGIN LAT J-02
45° FACTORY WYE
PAV STA 134+41.95, 25.50' RT
1+00.00 LAT J-02
2+33.98 LINE J =
CURVE 1 (CV J-1)
PULL RCP AT JOINTS
R = 6,224.50'
L = 716.54'
T = 358.67'
DEG = 0° 55' 13.76"
= 6° 35' 44.32" RT
E = 2404309.61
N = 7126510.23
PI STA = 4+62.39
CV J-1
PC CV J-1
BEGIN LINE J
CONNECT TO 3-6'x3' BOX CULVERT
10+11.48 LINE I
1+03.72 LINE J=
1"=40'H
1"=10'V
NOTES:CITY OF DENTON - McKINNEY STREET PHASE TWOINFORMATION.
PROFILE SHEETS FOR ADDITIONAL
SEE WATER AND WASTEWATER PLAN AND 3.
FOR ADDITIONAL INFORMATION.
2. SEE PAVING PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE DRAINAGE AREA MAP
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LINE-J_02.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LINE-J_02.dgn1:404:42:52 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
LINE J
STORM DRAIN PLAN & PROFILE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
V
S
5101 E McKINNEY STREET
DENTON ISD
E McKINNEY STREET
KIM Y PHAM
LOT 1R4
LOT 1, BLOCK A
CAB. H, PG. 6220' UTILITY EASEMENT
CAB. H, PG. 62
20' UTILITY EASEMENT
CAB. H, PG. 62
16' UTILITY EASEMENT
CAB. E, PG. 330
EASEMENT
4' SIDEWALK
CAB. E, PG. 330
4' SIDEWALK EASEMENT
CAB. E, PG. 3304' SIDEWALK EASEMENT
WV
WV
WV
FM
10" W 10" W
10" W
16" W 16" W
16" W
8" W8" W10" WW
10" WW10"WW PT 140+30.62137+00 138+00 139+00 140+00
141+00
16" W 16" W 16" W
16" W
16" W
6" PVC SLEEVES
D
5+00 6+00 7+00 8+00
9+0018" RCP
24" RCP
18" RCP
18"24" RCP
18"RCP
CLASS III24" RCP ON 0.88%
CLASS III24" RCP ON 0.88%
LINE J
45° FACTORY WYE1+00.00 LAT J-046+47.80 LINE J=END LINE J10' REC. INLET9+26.59 LINE JV=3.38 FPS
S=0.00222 FT/FT
C=21.21 CFS
Q100=10.63 CFS
V=2.08 FPS
S=0.00084 FT/FT
C=21.21 CFS
Q100=6.53 CFS
V=1.46 FPS
S=0.00041 FT/FT
C=21.21 CFS
Q100=4.58 CFS
CLASS III18" RCP ON 3.50%BEGIN 18" RCPEND 24" RCPSQUARE SDMHCONSTRUCT 4'x4'8+51.63 LINE JAT PIPE CL
PR. GRADE AT PIPE CL
EX. GROUNDHG 585.83HG 585.70100 YEAR HGL FLOW
PARTIAL
PARTIAL FLOW
V=2.59 FPS
S=0.00191 FT/FT
C=19.66 CFS
Q100=4.58 CFS
45° FACTORY WYE1+00.00 LAT J-068+31.63 LINE J=FL 581.86+/-
EX. 10" WW
RELOCATED BY OTHERS
CABLE TO BE
EX. TRAFFIC SIGNAL
BY OTHERS
RELOCATED
TO BE
EX. CCTV
BY OTHERS
RELOCATED
TO BE
EX.GAS
5+00 6+00 7+00FL 24"=581.63FL 24"=582.07FL 24"=582.51FL 24"=582.95FL 24"=583.39FL 24"=583.83FL 24"=584.27FL 24"=584.71FL 18"=586.92FL 18"=587.858+00 9+00FL 24"=584.72FL 24"=582.93FL 18"=583.18FL 24"=581.19FL 18"=585.22FL 18"=584.80FL 24"=584.55585
580
570
605
575
590
595
600
585
580
570
605
575
590
595
600MATCHLINE LINE J STA 4+50MATCHLINE LINE J STA 4+50LAT J-03
LINE J
LINE J
EX. R.O.W
EX. R.O.W
McKINNEY STREET
CL McKINNEY STREET
LAT J-04
END LINE J
F.L. 587.85
T.C. 592.35
CL 10' REC. INLET
PAV STA 141+15.50, 27.50' LT
9+26.59 LINE J
END LAT J-03
F.L. 584.70
T.C. 589.20
CL 10' REC. INLET
PAV STA 137, 27.50' LT
1+74.51 LAT J-03
END LAT J-4
F.L. 586.30
T.C. 590.80
CL 10' REC. INLET
PAV STA 139+10.00, 27.50' LT
1+74.63 LAT J-04
END LAT J-06
F.L. 587.36
T.C. 591.86
CL 10' REC. INLET
PAV STA 140+50.00, 33.50' RT
1+11.32 LAT J-0625.5'401.63 LF 24" RCP 74.96 LF 18" RCP
215
BEGIN LAT J-04
45° FACTORY WYE
PAV STA 138+91.95, 25.50' RT
1+00.00 LAT J-04
6+47.80 LINE J=
BEGIN 18" RCP
END 24" RCP
RIM 591.58
CONSTRUCT 4'x4' SQUARE SDMH
PAV STA 140+64.00, 25.50' RT
8+51.63 LINE J
J-06
LAT
PT CV J-1
8+20.26 LINE JCV J-1
CURVE 1 (CV J-1)
PULL RCP AT JOINTS
R = 6,224.50'
L = 716.54'
T = 358.67'
DEG = 0° 55' 13.76"
= 6° 35' 44.32" RT
E = 2404309.61
N = 7126510.23
PI STA = 4+62.39
BEGIN LAT J-06
45° FACTORY WYE
PAV STA 140+42.00, 25.50' RT
1+00.00 LAT J-06
8+31.63 LINE J=
1"=40'H
1"=10'V
NOTES:CITY OF DENTON - McKINNEY STREET PHASE TWOINFORMATION.
PROFILE SHEETS FOR ADDITIONAL
SEE WATER AND WASTEWATER PLAN AND 3.
FOR ADDITIONAL INFORMATION.
2. SEE PAVING PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE DRAINAGE AREA MAP
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LINE-K_01.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LINE-K_01.dgn1:404:42:54 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
LINE K
STORM DRAIN PLAN & PROFILE
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
S
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
E McKINNEY STREET
ATMOS ENERGY CORP
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
LOT 1
LOT 147B
CAB. E, PG. 60
16' UTILITY EASEMENT
CAB. E, PG. 60
16' UTILITY EASEMENT
FM
16" W 16" W
8" WW 8" WW 8" WW 8" WW6" WW145+00 146+00 147+00 148+00
16" W 16" W 16" W 16" W
D
4+005+006+007+0018"RCP18"18" RCP 18" RCP 18" RCP
CLASS III
18" RCP ON 2.62%
CLASS III
18" RCP ON 0.72%END LINE K10' REC. INLET7+61.38 LINE KSQUARE SDMHCONSTRUCT 4'x4'6+87.85 LINE K45° FACTORY WYE1+00.00 LAT K-026+61.43 LINE K=LINE K
V=2.30 FPS
S=0.00151 FT/FT
C=17.00 CFS
Q100=4.07 CFS
V=2.30 FPS
S=0.00151 FT/FT
C=8.93 CFS
Q100=4.07 CFS
V=4.38 FPS
S=0.00546 FT/FT
C=8.89 CFS
Q100=7.74 CFS
AT PIPE CL
EX. GROUND
AT PIPE CL
PR. GRADE HG 584.94HG 585.04HG 584.73HG 584.83HG 584.45HG 584.69100 YEAR HGL
4+005+006+007+00 FL 18"=579.12FL 18"=579.48FL 18"=579.84FL 18"=580.20FL 18"=580.56FL 18"=580.92FL 18"=582.82FL 18"=583.12FL 18"=581.19FL 18"=581.00585
580
570
565
575
590
595
McKINNEY STREET
585
580
570
565
575
590
595MATCHLINE LINE K STA 4+00MATCHLINE LINE K STA 4+00LAT K-02
LINE K
LINE K
LAT K-03
600600
END LINE K
F.L. 583.12
T.C. 587.62
CL 10' REC. INLET
PAV STA 145+50.00, 27.50' LT
7+61.38 LINE K 18" RCP25.5'361.38 LF 18" RCP
END LAT K-02
F.L. 582.19
T.C. 586.69
CL 10' REC. INLET
PAV STA 146+20.00, 33.50' RT
1+11.31 LAT K-02
END LAT K-03
F.L. 580.42
T.C. 584.92
CL 10' REC. INLET
PAV STA 148+70.00, 27.50' LT
1+74.95 LAT K-03
RIM 586.50
CONSTRUCT 4'x4' SQUARE SDMH
PAV STA 146+01.00, 25.50' RT
6+87.85 LINE K =
BEGIN LAT K-02
45° FACTORY WYE
1+00.00 LAT K-02
6+61.43 LINE K =
216
1"=40'H
1"=10'V
NOTES:CITY OF DENTON - McKINNEY STREET PHASE TWOINFORMATION.
PROFILE SHEETS FOR ADDITIONAL
SEE WATER AND WASTEWATER PLAN AND 3.
FOR ADDITIONAL INFORMATION.
2. SEE PAVING PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE DRAINAGE AREA MAP
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LINE-K_02.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LINE-K_02.dgn1:404:42:57 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
LINE K
STORM DRAIN PLAN & PROFILE
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
CONCRETE E
S S
S
E McKINNEY STREET
ATMOS ENERGY CORP
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
LOT 147B
LOT 1 LOT 1
CAB. E, PG. 60
16' UTILITY EASEMENT
CAB. E, PG. 60
16' UTILITY EASEMENT
WV
WV
FMFM
16" W
16" W
8" WW 8" WW
12" WW12" WW
8" WW 8" WW
16" W
16" W
18" RCP BOX CULVERT4.35'x4'3
-
3
6
" CMP6" WW8" WW
RCBEX.3-6'x3' PC 152+46.66149+00 150+00 151+00 152+00 153+00
154+00
16" W 16" W
16" W 16" W
6" PVC SLEEVES
0+001+004+00 2+003+00 2+0018" RCP18"24" RCP 24" RCP 18" RCP3'x2' RCB18"24" RCP24" RCP18" RCPCULVERTBOX 3-7'x3'CLASS III
ON 0.72%
18" RCP
CLASS III
24" RCP ON 0.52%BEGIN 18" RCPEND 24" RCP3+72.03 LINE K45° FACTORY WYE1+00.00 LAT K-043+31.43 LINE K=45° FACTORY WYE1+00.00 LAT K-033+66.43 LINE K=LINE K
45° FACTORY WYE1+00.00 LAT K-052+02.65 LINE K=V=4.38 FPS
FT/FT
S=0.00546
C=8.89 CFS
CFS
Q100=7.74
V=3.92 FPS
S=0.00298 FT/FT
C=16.34 CFS
Q100=12.33 CFS
V=4.67 FPS
S=0.00422 FT/FT
C=16.34 CFS
Q100=14.67 CFS
V=5.81 FPS
S=0.00653 FT/FT
C=16.34 CFS
Q100=18.22 CFS
AT PIPE CL
PR. GRADE
AT PIPE CL
EX. GROUND BEGIN LINE KPROP. 7'x3' RCBCONNECT TO10+11.47 LINE L1+04.55 LINE K=HG 580.20HG 580.88HG 581.52HG 581.79HG 582.33HG 582.49HG 582.77HG 582.87100 YEAR HGL
FL 569.38+/-
EX. 12" WWHG 582.60HG 582.772+003+004+00 1+00FL 24"=577.26FL 24"=577.52FL 24"=577.78FL 24"=578.04FL 24"=578.31FL 18"=578.64FL 24"=578.39FL 24"=578.21FL 18"=578.46FL 18"=578.92FL 24"=578.42FL 24"=577.02FL 7'x3'=576.82FL 18"=579.12FL 24"=577.54FL 24"=577.54LINE L
CONNECT LINE K1+04.55 LINE K10+11.47 LINE L=CONNECT LINE M1+03.75 LINE M10+11.53 LINE L=ON 0.20%PROP. 3-7'X3' RCB
V=8.18 FPS
S=0.00480 FT/FT
C=110.90 CFS
Q100=171.75 CFS
AT PIPE CL
PR. GRADE
AT PIPE CL
EX. GROUND BEGIN 3-6'X3'RCBTXDOT CH-PW-0CONSTRUCT 10+00.00 LINE LEND 3-6'X3'RCBTXDOT CH-PW-0CONSTRUCT 10+69.36 LINE LV=5.56 FPS
S=0.00221 FT/FT
C=110.90 CFS
=116.70 CFS
Q100 (PER BOX)HG 581.80HG 581.32HG 580.88HG 580.20TO BE KILLED
EX.16" WATERHG 580.14 100 YEAR HGL
3-36" CMP
EX.
RCB
4.35'X4'
EX. FL 7'X3'=576.80FL 7'X3'=576.90FL 7'X3'=576.941+00 2+00FL 7'x3'=576.82FL 24"=577.02FL 7'x3'=576.82FL 3'X2'=576.97TO BE KILLED
EX.16" WATER
585
580
570
565
575
590
595
EX. R.O.W
LAT K-04
25.5'EX. R.O.W
585
580
570
565
575
590
595S FORK ROADLAT K-03
MATCHLINE LINE K STA 4+00MATCHLINE LINE K STA 4+00560 560
217
18" RCPLINE L
LINE M3-7'X3'RCBLAT K-06
LINE K
267.48 LF 24" RCP
18" RCP
37.97 LF
BEGIN LAT K-05
45° FACTORY WYE
PAV STA 150+86.78, 25.50' RT
1+00.00 LAT K-05
2+02.65 LINE K =
BEGIN LAT K-04
45° FACTORY WYE
PAV STA 149+58.00, 25.50' RT
1+00.00 LAT K-04
3+31.43 LINE K =
BEGIN LAT K-03
45° FACTORY WYE
1+00.00 LAT K-03
3+66.43 LINE K =
BEGIN 18" RCP
END 24" RCP
3+72.03 LINE K
69.36 LF 3-7'x3' RCB
BEGIN LAT K-06
45° FACTORY WYE
PAV STA 150+49.08, 12.19' LT
1+00.00 LAT K-06
1+53.31 LAT K-05 =
LAT K-05
END LAT K-04
F.L. 579.85
T.C. 584.35
CL 10' REC. INLET
PAV STA 149+50.00, 33.50' RT
1+11.31 LAT K-04
END LAT K-05
F.L. 578.94
T.C. 583.94
CL 10' STD. INLET
PAV STA 149+98.96, 62.32' LT
2+24.19 LAT K-05
F.L. 578.57
T.C. 583.07
CL 10' STD. INLET
PAV STA 150+47.92, 60.50' LT
END LAT K-06
CONNECT TO PROP. INLET
PAV STA 150+49.08, 55.50' LT
1+43.31 LAT K-06
BEGIN LINE K
CONNECT TO LINE L
10+11.47 LINE L
1+04.55 LINE K=
585
580
570
565
575
590
595
560
McKINNEY STREET
LOT 1
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
BEGIN LINE L
72 SY TYPE R STONE RIPRAP
FOR 3-7'x3' BOX CULVERT
CONSTRUCT TXDOT CH-PW-0
PAV STA 151+93.67, 37.00' RT
10+00.00 LINE L
END LINE L
36 SY TYPE R STONE RIPRAP
FOR 3-7'x3' BOX CULVERT
CONSTRUCT TXDOT CH-PW-0
PAV STA 151+93.91, 32.36' LT
10+69.36 LINE L
1"=40'H
1"=10'V
NOTES:CITY OF DENTON - McKINNEY STREET PHASE TWOINFORMATION.
PROFILE SHEETS FOR ADDITIONAL
SEE WATER AND WASTEWATER PLAN AND 3.
FOR ADDITIONAL INFORMATION.
2. SEE PAVING PLAN AND PROFILE SHEETS
FOR ADDITIONAL INFORMATION.
1. SEE DRAINAGE AREA MAP
McKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LINE-M.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LINE-M.dgn1:404:43:00 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
LINE M
STORM DRAIN PLAN & PROFILE
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
E
S
S
E McKINNEY STREET
ATMOS ENERGY CORP
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
E McKINNEY STREET
ATMOS ENERGY CORP
LOT 147B
LOT 1
LOT 147A
CAB. E, PG. 60
16' UTILITY EASEMENT
WV
FMFM
16" W
8" WW
12" WW12" W W
8" WW 8" WW
16" W
16" W
8" WW
18" RCP BOX CULVERT4.35'x4'3-
3
6
" CMP
3'x2' RCBRCBEX.3-6'x3' PC 152+46.66150+00 151+00 152+00 153+00
154+00
155+00
16" W
16" W 16" W
16" W
6" PVC SLEEVES
0+001+002+003+00 2+00
3+00
24" RCP 24" RCP 18" RCP3'x2' RCB
18" RCP
18"24" RCP24" RCP18" RCPCULVERTBOX 3-7'x3'45° FACTORY WYE1+00.00 LAT M-021+34.18 LINE M=45° FACTORY WYE1+00.00 LAT M-011+58.01 LINE M=45° FACTORY WYE1+00.00 LAT K-032+68.58 LINE M=45° FACTORY WYE1+00.00 LAT M-042+95.61 LINE M=END LINE MEX. 3'x2' RCBCONNECT TO3+38.83 LINE MON 0.25%
EX. 3'x2' RCB
LINE M
AT PIPE CL
PR. GRADE
3'x2' RCB ON 0.20%
V=6.14 FPS
S=0.00570 FT/FT
C=21.82 CFS
Q100=36.84 CFS 3.67° BENDINSTALL2+00.61 LINE MV=5.66 FPS
S=0.00484 FT/FT
C=21.82 CFS
Q100=33.94 CFS
V=5.21 FPS
S=0.00410 FT/FT
C=21.82 CFS
Q100=31.26 CFS
V=5.21 FPS
S=0.00410 FT/FT
C=21.82 CFS
Q100=31.26 CFS
V=4.45 FPS
S=0.00300 FT/FT
C=21.82 CFS
Q100=26.71 CFS
V=4.08 FPS
S=0.00252 FT/FT
C=21.82 CFS
Q100=24.48 CFS
AT PIPE CL
EX. GROUNDBEGIN LINE MPROP. 7'x3' RCBCONNECT TO10+11.53 LINE L1+03.75 LINE M=HG 580.88HG 580.20HG 581.27HG 581.05HG 581.56HG 581.38HG 581.84HG 581.74HG 582.31HG 582.12HG 582.50HG 582.39HG 582.71HG 582.61100 YEAR HGL
3+002+001+00 FL 3'x2'=577.44FL 3'x2'=577.36FL 3'x2'=577.26FL 3'x2'=577.16FL 3'x2'=577.06FL 7'x3'=576.82FL 3'x2'=576.97FL 18"=577.60FL 3'x2'=577.35FL 3'x2'=577.30FL 3'x2'=577.08FL 18"=577.55FL 18"=577.33FL 18"=577.28FL 3'x2'=577.03LINE M
585
580
570
565
575
590
McKINNEY STREET
EX. R.O.W
LAT M-0425.5'EX. R.O.W
585
580
570
565
575
590S FORK ROADLAT M-03
560 560
555
218
LINE K LINE L 3-7'X3'RCBBEGIN LINE M
CONNECT TO PROP. 7'x3' RCB
10+11.53 LINE L
1+03.75 LINE M =
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
LOT 1
235.08 LF 3'x2' RCB
END LAT M-03
F.L. 579.17
T.C. 583.67
CL 10' REC. INLET
PAV STA 154+30.00, 30.18' LT
1+85.05 LAT M-03
END LINE M
CONNECT TO EX. 3'X2'
3+38.83 LINE M
BEGIN LAT M-04
45° FACTORY WYE
1+00.00 LAT M-04
2+95.61 LINE M =
END LAT M-04
F.L. 579.00
T.C. 583.50
CL 10' REC. INLET
PAV STA 154+00.00, 33.52' RT
1+05.58 LAT M-04
BEGIN LAT M-03
45° FACTORY WYE
1+00.00 LAT M-03
2+68.58 LINE M=
BEGIN LAT M-01
45° FACTORY WYE
1+00.00 LAT M-01
1+58.01 LINE M =
END LAT M-01
F.L. 578.27
T.C. 582.77
CL 10' REC. INLET
PAV STA 152+65.00, 33.50' RT
1+11.29 LAT M-01
END LAT M-02
F.L. 578.27
T.C. 582.77
CL 10' REC. INLET
PAV STA 152+65.00, 30.47' LT
1+64.54 LAT M-02
M-01
LAT
595 595
PC CV M-1
1+47.86 LINE M
CV H-1
CURVE 1 (CV M-1)
PT CV M-1
INSTALL 3.67°BEND
2+00.61 LINE M
PULL RCP AT JOINTS
R = 2,266.33'
L = 52.75'
T =26.38'
DEG = 2° 31' 41.27"
= 1° 20' 00.89" RT
E = 2405719.78
N = 7125752.03
PI STA = 1+74.24
LAT M-02
BEGIN LAT M-02
45° FACTORY WYE
1+00.00 LAT M-02
1+34.18 LINE M =
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LAT-01.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LAT-01.dgn1:404:43:02 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
LATERAL PROFILES
STORM DRAIN PLAN & PROFILE
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
1+00 FL 30"=583.93BEGIN LAT A-02CONNECT TO SDMH5+76.03 LINE A1+00.00 LAT A-02=AT PIPE CL
PR. GRADE
LAT A-02
CLASS III
ON 0.51% 30" RCP FL 24"=583.78FL 4'x2=583.78FL 30"=583.78END LAT A-02CONNECT 30" RCPDROP INLETCONSTRUCT 4'X4' 1+29.50 LAT A-02 HG 586.76HG 587.66HG 587.18HG 586.83100 YEAR HGL
AT PIPE CL
EX. GROUND
V=3.95 FPS
S=0.00224 FT/FT
C=29.28 CFS
Q100=19.40 CFS
FL 579.46
PROP. 20" WATER
TO BE KILLED
EX. 8" WATER
1+00 BEGIN LAT A-0445°FACTORY WYE6+46.17 LINE A1+00.00 LAT A-04=FL 18"=584.49FL 24"=583.92AT PIPE CL
PR. GRADE
CLASS III
18" RCP ON 2.83%
LAT A-04
END LAT A=04CONNECT 18" RCP10' REC. INLET1+11.30 LAT A-04FL 18"=584.17AT PIPE CL
EX. GROUND
100 YEAR HGL
V=2.06 FPS
S=0.00121 FT/FT
C=17.66 CFS
Q100=3.64 CFS
HG 587.18HG 587.08HG 587.07HG 586.941+00 FL 18"=584.36BEGIN LAT B-0145° FACTORY WYE2+34.59 LINE B1+00.00 LAT B-01=AT PIPE CL
PR. GRADE FL 24"=584.28FL 18"=584.28END LAT B-01CONNECT 18" RCP10' REC. INLET1+06.29 LAT B-01 CLASS III
18" RCP ON 1.27%
LAT B-01
HG 587.58HG 587.48100 YEAR HGL HG 587.81HG 587.60V=3.30 FPS
S=0.00311 FT/FT
C=11.83 CFS
Q100=5.84 CFS
AT PIPE CL
EX. GROUND
1+00FL 18"=583.30FL 18"=583.90FL 18"=584.21CLASS III18" RCP ON 1.21%FL 18"=583.301+00.00 LAT C-02=1+75.34 LAT C-02BEGIN LAT C-0245° FACTORY WYE12+51.99 LINE CLAT C-02
BY OTHERS
TO BE RELOCATED
FIBER OPTIC END LAT C-02CONNECT 18" RCP10' REC. INLETAT PIPE CL
PR. GRADE
AT PIPE CL
EX. GROUND
HG 584.89HG 584.60HG 585.19HG 585.05100 YEAR HGL
V=2.72 FPS
S=0.00211 FT/FT
C=11.55 CFS
Q100=4.81 CFS
1+00FL 24"=578.84FL 18"=581.23FL 18"=582.30CLASS III18" RCP ON 1.60%FL 18"=579.09AT PIPE CL
PR. GRADE 1+74.94 LAT C-04BEGIN LAT C-0445° FACTORY WYE10+01.78 LINE C1+00.00 LAT C-04=LAT C-04
END LAT C-04CONNECT 18" RCP10' REC. INLETAT PIPE CL
EX. GROUND
AT PIPE CL
PR. GRADE HG 583.10HG 583.00HG 583.22HG 583.12100 YEAR HGL
V=1.13 FPS
S=0.00037 FT/FT
C=13.30 CFS
Q100=2.00 CFS
BY OTHERS
TO BE RELOCATED
FIBER OPTIC FLOW
PARTIAL
1+00 FL 18"=580.70FL 24"=577.44FL 18"=577.69 CLASS III
18" RCP ON 26.54%1+11.34 LAT C-041+00.00 LAT C-05=BEGIN LAT C-0545° FACTORY WYE8+46.06 LINE CAT PIPE CL
PR. GRADE
LAT C-05
END LAT C-05CONNECT 18" RCP10' REC. INLETAT PIPE CL
EX. GROUND HG 582.69HG 582.51HG 582.84HG 582.71100 YEAR HGL
V=2.53 FPS
S=0.00182 FT/FT
C=54.10 CFS
Q100=4.47 CFS
585
580
575
590
575
580
585
590
570
219
11.3 LF 18" RCP
75.34 LF 18" RCP 74.94 LF 18" RCP
11.34 LF 18" RCP
6.29 LF 18" RCP
575
580
585
590
585
580
575
590
570
585
580
575
590
570
585
580
575
590
570
29.5 LF 30" RCP'
595595
580
585
590
595
575
580
585
590
595
575
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LAT-02.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LAT-02.dgn1:404:43:04 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
LATERAL PROFILES
STORM DRAIN PLAN & PROFILE
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
2+001+00 FL 36"=579.54CLASS III36" RCP ON 3.96%1+00.00 LAT C-06=BEGIN LAT C-06SQUARE SDMHCONSTRUCT 6'X6'7+63.23 LINE CAT PIPE CL
PR. GRADE
LAT C-06
FL 36"=575.85FL 36"=575.85FL 24"=576.85FL 36"=577.83FL 36"=578.1945° FACTORY WYE1+00.00 LAT C-071+59.06 LAT C-06=FL 18"=578.94END LAT C-06CONNECT 36" RCPDROP INLETCONSTRUCT 6'X6'1+93.13 LAT C-06AT PIPE CL
EX. GROUND
HG 582.20HG 581.85HG 582.39HG 582.29HG 582.69HG 582.441OO YEAR HGL
V=3.75 FPS
S=0.00158 FT/FT
C=132.68 CFS
Q100=26.48 CFS
V=3.55 FPS
S=0.00142 FT/FT
C=132.68 CFS
Q100=25.08 CFS
FL 574.63
PROP. 20" WATER
TO BE KILLED
EX. 8" WATER
2+001+00 FL 30"=576.85FL 30"=578.281+00.00 LAT C-08=1+92.89 LAT C-08CLASS III30" RCP ON 3.33%FL 30"=575.19AT PIPE CL
PR. GRADE
LAT C-08
END LAT C-08CONNECT 30" RCPDROP INLETCONSTRUCT 5'X5'BEGIN LAT C-08SQUARE SDMHCONSTRUCT 6'X6' 5+52.75 LINE CFL 48"=574.44FL 36"=575.44AT PIPE CL
EX. GROUND HG 580.61HG 580.51HG 581.09HG 580.811OO YEAR HGL
V=3.81 FPS
S=0.00208 FT/FT
C=74.78 CFS
Q100=18.68 CFS
FL 573.15
PROP. 20" WATER
1+00FL 36"=575.68FL 18"=579.22FL 18"=576.431+11.29 LAT C-09BEGIN LAT C-0945° FACTORY WYE6+78.57 LINE C1+00.00 LAT C-09= CLASS III
18" RCP ON 24.72%
LAT C-09
END LAT C-09CONNECT 18" RCP10' REC. INLETAT PIPE CL
PR. GRADE
AT PIPE CL
EX. GROUND HG 581.54HG 581.35HG 581.66HG 581.561OO YEAR HGL
V=2.26 FPS
S=0.00145 FT/FT
C=52.21 CFS
Q100=3.99 CFS
1+00FL 36"=575.48FL 18"=578.37FL 18"=576.23 CLASS III
18" RCP ON 18.96%1+11.29 LAT C-11BEGIN LAT C-1145° FACTORY WYE5+77.02 LINE C1+00.00 LAT C-11=LAT C-11
END LAT C-11CONNECT 18" RCP10' REC. INLETHG 580.93HG 580.71HG 581.06HG 580.95AT PIPE CL
EX. GROUND
AT PIPE CL
PR. GRADE
1OO YEAR HGL
V=2.38 FPS
S=0.00161 FT/FT
C=45.72 CFS
Q100=4.20 CFS
1+00FL 18"=579.15FL 5'X2'=578.90 CLASS III
18" RCP ON 11.49%FL 18"=580.451+11.32 LAT G-041+00.00 LAT G-04=AT PIPE CL
PR. GRADE
LAT G-04
BEGIN LAT G-04CONNECTION45° LATERAL5+52.62 LINE GEND LAT G-04CONNECT 18" RCP10' REC. INLETAT PIPE CL
EX. GROUND HG 582.88HG 582.76HG 583.05HG 582.90
V=2.79 FPS
S=0.00222 FT/FT
C=35.59 CFS
Q100=4.93 CFS
100 YEAR HGL
1+00
LAT C-07
FL 18"=580.63BEGIN LAT C-0745° FACTORY WYE1+59.06 LAT C-061+00.00 LAT C-07=FL 36"=578.19FL 18"=578.94 CLASS III
18" RCP ON 14.35%END LAT C-07CONNECT 18" RCP10' REC. INLET1+11.78 LAT C-07HG 582.39HG 582.29HG 582.50HG 582.40AT PIPE CL
EX. GROUND
AT PIPE CL
PR. GRADE
1OO YEAR HGL
V=1.13 FPS
S=0.00036 FT/FT
C=39.78 CFS
Q100=1.99 CFS
575
580
585
590
570
220
93.13 LF 36" RCP 92.89 LF 30" RCP
11.29 LF 18" RCP 11.29 LF 18" RCP 11.32 LF 18" RCP
575
580
585
590
570
575
580
585
590
570
575
580
585
590
570
585
580
575
590
570
585
580
575
590
570
575
580
585
590
570
575
580
585
590
570
11.78 LF 18" RCP
226 227
AND LATERALS G-01 TO G-03
LATERALS C-10 TO C-18
SEE SHEETS - FOR
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LAT-03.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LAT-03.dgn1:404:43:07 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
LATERAL PROFILES
STORM DRAIN PLAN & PROFILE
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
2+001+00 FL 24"=580.61FL 24"=581.19CLASS III24" RCP ON 2.29%FL 24"=579.47FL 5'X2'=579.471+00.00 LAT G-06=1+75.13 LAT G-06LAT G-06
BEGIN LAT G-06CONNECTION45° LATERAL6+62.16 LINE GEND LAT G-06CONNECT 24" RCP20' REC. INLETAT PIPE CL
PR. GRADE
AT PIPE CL
EX. GROUND HG 583.27HG 583.11
V=4.33 FPS
S=0.00363 FT/FT
C=34.22 CFS
Q100=13.60CFS
HG 583.91HG 583.55100 YEAR HGL
BY OTHERS
TO BE RELOCATED
EX. FIBER
2+001+00FL 36"=580.10FL 36"=580.24FL 36"=580.36CLASS III36" RCP ON 0.28%BEGIN LAT H-0160° FACTORY WYE5+97.91 LINE H1+00.00 LAT H-01=END LAT H-01CONNECT 36" RCP5'X5' DROP INLET1+92.96 LAT H-01LAT H-01
FL 36"=580.10AT PIPE CL
PR. GRADE
AT PIPE CL
EX. GROUNDHG 585.00HG 584.78V=3.66 FPS
S=0.00151 FT/FT
C=35.28 CFS
Q100=25.88 CFS
HG 585.40HG 585.14100 YEAR HGL
BY OTHERS
TO BE RELOCATED
EX. FIBER, GAS, CCTV
2+001+00 FL 18"=582.17FL 18"=582.67BEGIN LAT H-0260° FACTORY WYE6+71.02 LINE H1+00.00 LAT H-02=END LAT H-02CONNECT 18" RCP10' REC. INLET1+74.95 LAT H-02CLASS III18" RCP ON 2.00%FL 18"= 581.17FL 36"= 580.42LAT H-02
AT PIPE CL
EX. GROUND
AT PIPE CL
PR. GRADE HG 585.10HG 585.00V=1.62 FPS
S=0.00074 FT/FT
C=14.85 CFS
Q100=2.86 CFS
HG 585.26HG 585.16100 YEAR HGL
BY OTHERS
TO BE RELOCATED
EX. FIBER
2+001+00
LAT H-04
END LAT H-04CONNECT 18" RCP10' REC. INLET1+74.95 LAT H-04FL 18"=581.67FL 18"=581.22BEGIN LAT H-04SQUARE SDMHCONSTRUCT 6'X6'4+76.39 LINE H1+00.00 LAT H-04=AT PIPE CL
EX. GROUND
AT PIPE CL
PR. GRADE FL 18"= 580.33FL 4'X3'= 579.58FL 36"= 579.5818" RCP ON 1.79% CLASS IIIHG 584.35HG 584.25V=1.96 FPS
S=0.00109 FT/FT
C=14.05 CFS
Q100=3.46 CFS
HG 584.53HG 584.43100 YEAR HGL
BY OTHERS
TO BE RELOCATED
EX. FIBER
1+00 FL 18"=580.94LAT H-05
FL 18"= 580.57FL 36"= 579.82CLASS III18" RCP ON 0.58%END LAT H-05CONNECT 18" RCP2'X2' DROP INLET1+63.63 LAT H-05INSTALL 22.5° BEND1+09.69 LAT H-05INSTALL 22.5° BEND1+20.03 LAT H-0545° FACTORY WYE5+33.58 LINE H1+00.00 LAT H-05=FL 18"=580.86AT PIPE CL
EX. GROUND
AT PIPE CL
PR. GRADE HG 584.67HG 584.49HG 585.62HG 585.23HG 584.83HG 584.73HG 584.99HG 584.89100 YEAR HGL
BY OTHERS
TO BE RELOCATED
EX. FIBER
BY OTHERS
RELOCATED
EX. GAS TO BE
V=4.45 FPS
S=0.00564 FT/FT
C=8.00 CFS
Q100=7.86 CFS
2+001+00 FL 18"=581.17FL 18"= 581.80END LAT H-06CONNECT 18" RCP10' REC. INLET1+74.70 LAT H-06LAT H-06
AT PIPE CL
PR. GRADE
AT PIPE CL
EX. GROUND
FL 18"= 579.91FL 4'X3'= 579.1618" RCP ON 2.53% CLASS IIIBEGIN LAT H-06CONNECTION45° LATERAL4+03.32 LINE H1+00.00 LAT H-06=HG 584.19HG 584.09
V=1.84 FPS
S=0.00096 FT/FT
C=16.70 CFS
Q100=3.25 CFS
HG 584.36HG 584.24100 YEAR HGL
BY OTHERS
TO BE RELOCATED
EX. FIBER
585
580
575
590
575
580
585
590
570
570
570
575
580
585
590
570
575
580
585
590
221
75.13 LF 24" RCP 92.96 LF 36" RCP 74.95 LF 18" RCP
74.95 LF 18" RCP
63.63 LF 24" RCP
74.70 LF 18" RCP
575
580
585
590
570
575
580
585
590
570
585
580
575
590
570
585
580
575
590
570
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LAT-04.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LAT-04.dgn1:404:43:09 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
LATERAL PROFILES
STORM DRAIN PLAN & PROFILE
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
2+001+00 FL 24"=580.18FL 24"=580.74CLASS III24" RCP ON 2.29%BEGIN LAT H-0945° FACTORY WYE1+00.00 LAT H-091+50.64 LAT H-07=CONNECT 24" RCP10' REC. INLET1+74.65 LAT H-07FL 24"=581.06END LAT H-07PLUG 24" RCP2+06.26 LAT H-07LAT H-07
FL 24"=579.03OTHERS
RELOCATED BY
& FOC TO BE
CTV, GAS,FL 24"=581.00FL 24"=580.18AT PIPE CL
PR. GRADE
AT PIPE CL
EX. GROUND
FL 4'X3'=578.53BEGIN LAT H-07CONNECTION45° LATERAL2+89.39 LINE H1+00.00 LAT H-07=HG 583.87HG 583.75HG 584.04HG 583.94HG 584.14HG 584.04V=2.65 FPS
S=0.00136 FT/FT
C=34.19 CFS
Q100=8.32 CFS
V=0.86 FPS
S=0.00014 FT/FT
C=34.25 CFS
Q100=2.71 CFS
100 YEAR HGL
ON 1.00%
24" CL III RCP
1+00 END LAT H-08CONNECT 18" RCP10' REC. INLET1+11.32 LAT H-08 CLASS III
18" RCP ON 15.02%FL 18"=581.24LAT H-08
AT PIPE CL
PR. GRADE AT PIPE CL
EX. GROUND BEGIN LAT H-08CONNECTION45° LATERAL3+36.74 LINE H1+00.00 LAT H-08=FL 18"= 579.54FL 4'X3'= 578.79HG 584.02HG 583.92HG 584.14HG 584.04V=2.22 FPS
S=0.00141 FT/FT
C=40.70 CFS
Q100=3.93 CFS
100 YEAR HGL
BY OTHERS
TO BE RELOCATED
EX. FIBER
1+00FL 24"=580.19FL 24"=580.81BEGIN LAT H-0945° FACTORY WYE1+50.64 LAT H-071+00.00 LAT H-09= CLASS III
24" RCP ON 2.10%END LAT H-09SQUARE SDMHCONNECT TO 4'X4'1+29.59 LAT H-09=RELOCATED BY OTHERS
CTV & ELEC TO BE
LAT H-09
FL 24"=580.19AT PIPE CL
EX. GROUND
AT PIPE CL
PR. GRADE
V=1.94 FPS
S=0.00073 FT/FT
C=32.77 CFS
Q100=6.10 CFS
HG 584.04HG 583.75HG 584.16HG 584.06100 YEAR HGL
2+001+00 FL 36"=578.44FL 36"=578.94FL 36"=579.40END LAT H-10CONNECT 36" RCPSTD. 15' INLET2+46.70 LAT H-10FL 36"=578.37FL 36"=578.37LAT H-10
CLASS III36" RCP ON 1.00%
STANDARD DETAILS
CITY OF DENTON
ACCORDING TO
BE LOWERED
EX. 8" WATER TO BOP 576.02 ±BEGIN LAT H-1145° FACTORY WYE1+00.00 LAT H-111+42.90 LAT H-10=AT PIPE CL
PR. GRADE FL 36"= 577.94FL 5'X3'= 577.94BEGIN LAT H-10CONNECTION45° LATERAL1+84.47 LINE H1+00.00 LAT H-10=HG 583.60HG 583.47
V=3.47 FPS
S=0.00135 FT/FT
C=66.54 CFS
Q100=24.50 CFS
V=1.02 FPS
S=0.00012 FT/FT
C=66.54 CFS
Q100=7.23 CFS
HG 583.84HG 583.66HG 583.95HG 583.85AT PIPE CL
EX. GROUND
100 YEAR HGL OTHERS
RELOCATED BY
& GAS TO BE
CTV, CTV,
2+001+00 FL 36"=578.48FL 36"=578.52END LAT H-11CONNECT 36" RCPSTD. 15' INLET1+69.86 LAT H-11BEGIN LAT H-1145° FACTORY WYE1+42.90 LAT H-101+00.00 LAT H-11=CLASS III36" RCP ON 0.21%
LAT H-11
FL 36"=578.37FL 36"=578.37RELOCATED BY OTHERS
CABLE TO BE
& TRAFFIC SIGNAL
CTV, GAS,
AT PIPE CL
PR. GRADE
BOP 575.47 ±
STANDARD DETAILS
CITY OF DENTON
ACCORDING TO
BE LOWERED
WATER TO
EX. 8"
V=2.64 FPS
S=0.00079 FT/FT
C=30.55 CFS
Q100=18.69 CFS
HG 583.84HG 583.47HG 584.03HG 583.89100 YEAR HGL
AT PIPE CL
EX. GROUND
1+00
CLASS III
18" RCP ON 15.72%END LAT H-12CONNECT 18" RCP10' REC. INLET1+11.32 LAT H-12FL 18"= 580.46LAT H-12
AT PIPE CL
PR. GRADE AT PIPE CL
EX. GROUND FL 18"= 578.68FL 5'X3'= 577.93BEGIN LAT H-12CONNECTION45° LATERAL1+82.37 LINE H1+00.00 LAT H-12=HG 583.60HG 583.47V=1.09 FPS
S=0.00034 FT/FT
C=41.63 CFS
Q100=1.93 CFS
HG 583.71HG 583.61100 YEAR HGL
BY OTHERS
TO BE RELOCATED
EX. FIBER
585
580
575
590
575
580
585
590
570
570
570
575
580
585
590
570
575
580
585
590
222
11.32 LF 18" RCP
11.32 LF 18" RCP
146.7 LF 30" RCP
69.86 LF 30" RCP
575
580
585
590
570
575
580
585
590
570
585
580
575
590
570
585
580
575
590
570
106.26 LF 24" RCP 24" RCP
29.59 LF
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LAT-05.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LAT-05.dgn1:404:43:11 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
LATERAL PROFILES
STORM DRAIN PLAN & PROFILE
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
1+00 FL 18"=579.94FL 18"=578.26 CLASS III
18" RCP ON 4.93%FL 6'x3'=577.72BEGIN LAT I-02BOX CULVERTCONNECT TO 3-6'x3'10+40.27 LINE I1+00.00 LAT I-02=AT PIPE CL
PR. GRADE
LAT I-02
AT PIPE CL
EX. GROUND END LAT J-01CONNECT 18" RCP15' REC. INLET1+34.08 LAT I-02V=3.93 FPS
S=0.00440 FT/FT
C=23.32 CFS
Q100=6.94 CFS
HG 582.67HG 582.48HG 583.12HG 582.82100 YEAR HGL
1+00 FL 18"=579.94 CLASS III
18" RCP ON 14.50%END LAT J-00CONNECT 18" RCP10' REC. INLET1+11.31 LAT J-00FL 18"=578.30FL 30"=577.80BEGIN LAT J-00CONNECT TO 30" RCP1+19.47 LINE J1+00.00 LAT J-00=LAT J-00
AT PIPE CL
PR. GRADE AT PIPE CL
EX. GROUND HG 583.68HG 583.58HG 583.57HG 583.38V=1.74 FPS
S=0.00086 FT/FT
C=39.99 CFS
Q100=3.08 CFS
100 YEAR HGL
1+00FL 24"=579.54FL 18"=579.79FL 18"=582.81CLASS III18" RCP ON 4.97%
LAT J-01
END LAT J-01CONNECT 18" RCP10' REC. INLET1+60.80 LAT J-01BEGIN LAT J-01SQUARE SDMHCONNECT TO 4'x4'2+62.66 LINE J1+00.00 LAT J-01=AT PIPE CL
PR. GRADE
AT PIPE CL
EX. GROUNDHG 584.32HG 584.22V=3.20 FPS
S=0.00291 FT/FT
C=23.41 CFS
Q100=5.65 CFS
HG 584.70HG 584.50100 YEAR HGL
1+00FL 18"=579.29FL 30"=578.79 CLASS III
18" RCP ON 15.55%FL 18"=581.05BEGIN LAT J-0245° FACTORY WYE2+33.98 LINE J1+00.00 LAT J-02=END LAT J-02CONNECT 18" RCP10' REC. INLET1+11.32 LAT J-02LAT J-02
AT PIPE CL
EX. GROUND
AT PIPE CL
PR. GRADE HG 584.16HG 583.97HG 584.41HG 584.20V=3.28 FPS
S=0.00306 FT/FT
C=41.41 CFS
Q100=5.80 CFS
100 YEAR HGL
BY OTHERS
TO BE RELOCATED
EX. FIBER
1+00FL 18"=581.34FL 24"=581.09LAT J-03
END LAT J-03CONNECT 18" RCP10' REC. INLET1+74.51 LAT J-03FL 18"=584.70CLASS III18" RCP ON 4.51%BEGIN LAT J-0345° FACTORY WYE4+38.65 LINE J1+00.00 LAT J-03=BY OTHERS
RELOCATED
CABLE TO BE
TRAFFIC SIGNAL
AT PIPE CL
EX. GROUNDHG 585.23HG 585.04V=2.57 FPS
S=0.00188 FT/FT
C=22.30 CFS
Q100=4.54 CFS
AT PIPE CL
PR. GRADE
100 YEAR HGL
FLOW
PARTIAL
1+00 FL 18"=586.30BEGIN LAT J-0445° FACTORY WYE6+47.80 LINE J1+00.00 LAT J-04=FL 18"=583.18FL 24"=582.93END LAT J-04CONNECT 18" RCP10' REC. INLET1+74.63 LAT J-04LAT J-04
CLASS III18" RCP ON 4.18%FL 18"=585.27AT PIPE CL
EX. GROUND
AT PIPE CL
PR. GRADE HG 585.83HG 585.70V=2.68 FPS
S=0.00205 FT/FT
C=21.47 CFS
Q100=4.74 CFS
FLOW
PARTIAL
585
580
575
590
575
580
585
590
570
570
570
575
580
585
590
575
580
585
590
223
565
570
575
580
585
570
575
580
585
590
34.08 LF 18" RCP 11.31 LF 18" RCP
60.8 LF 18" RCP
11.32 LF 18" RCP 74.51 LF 18" RCP 74.63 LF 18" RCP
585
580
575
590
585
580
575
590
595595595
585
580
575
590
570
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LAT-06.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LAT-06.dgn1:404:43:14 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
LATERAL PROFILES
STORM DRAIN PLAN & PROFILE
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
1+00 END LAT J-06CONNECT 18" RCP10' REC. INLET1+11.32 LAT J-06FL 18"=587.36BEGIN LAT J-0645° FACTORY WYE8+31.63 LINE J1+00.00 LAT J-06= CLASS III
18" RCP ON 22.62%
LAT J-06
AT PIPE CL
PR. GRADE FL 18"=584.80FL 24"=584.55AT PIPE CL
EX. GROUND HG 586.08HG 585.98FLOW
PARTIAL
V=1.19 FPS
S=0.00040FT/FT
C=49.94 CFS
Q100=2.10 CFS
BY OTHERS
TO BE RELOCATED
EX. FIBER
1+00
LAT K-02
AT PIPE CL
PR. GRADE FL 18"=581.00BEGIN LAT K-0245° FACTORY WYE6+61.43 LINE K1+00.00 LAT K-02= CLASS III
18" RCP ON 10.52%FL 18"=582.19END LAT K-02CONNECT 18" RCP10' REC. INLET1+11.31 LAT K-02AT PIPE CL
EX. GROUND HG 584.69HG 584.45HG 584.80HG 584.70V=2.13 FPS
S=0.00129 FT/FT
C=34.06 CFS
Q100=3.76 CFS
100 YEAR HGL
1+00
LAT K-03
AT PIPE CL
PR. GRADE FL 18"=578.64FL 24"=578.39BEGIN LAT K-0345° FACTORY WYE3+66.43 LINE K1+00.00 LAT K-03=FL 18"=580.42CLASS III18" RCP ON 2.37%FL 18"=579.83END LAT K-03CONNECT 18" RCP10' REC. INLET1+74.95 LAT K-03AT PIPE CL
EX. GROUNDHG 582.77HG 582.60HG 583.01HG 582.89100 YEAR HGL
V=2.44 FPS
S=0.00170 FT/FT
C=16.17 CFS
Q100=4.31 CFS
1+00FL 18"=578.46FL 24"=578.21BEGIN LAT K-0445° FACTORY WYE3+31.43 LINE K1+00.00 LAT K-04=FL 18"=579.85 CLASS III
18" RCP ON 12.29%END LAT K-04CONNECT 18" RCP10' REC. INLET1+11.31 LAT K-04LAT K-04
AT PIPE CL
EX. GROUND
AT PIPE CL
PR. GRADE HG 582.49HG 582.33V=1.93 FPS
S=0.00106 FT/FT
C=36.81 CFS
Q100=3.41 CFS
HG 582.61HG 582.51100 YEAR HGL
1+00 2+00
LAT K-05
BEGIN LAT K-0545° FACTORY WYE2+02.65 LINE K1+00.00 LAT K-05=FL 24"=577.54CLASS III24" RCP ON 1.13%END LAT K-05CONNECT 24" RCP10' STD. INLET2+24.19 LAT K-05FL 18"=578.94FL 18"=578.67FL 18"=578.10FL 24"=577.54FL 18"=578.36FL 24"=578.14BEGIN LAT K-0545° FACTORY WYE1+00.00 LAT K-061+53.31 LAT K-05=AT PIPE CL
EX. GROUND
AT PIPE CL
PR. GRADE HG 581.79HG 581.52HG 581.91HG 581.81HG 582.02HG 581.92 BY OTHERS
RELOCATED
GAS TO BE
V=1.25 FPS
S=0.00030 FT/FT
C=24.04 CFS
Q100=3.92 CFS
V=0.93 FPS
S=0.00017 FT/FT
C=24.04 CFS
Q100=2.91 CFS
BE KILLED
WATER TO
EX. 8"
FL 570.19+/-
EX.12" WW
FL 572.20+/-
EX. 8" WW
HGL
100 YEAR
FL 574.89
PROP.16" W
1+00FL 18"=578.36FL 24"=578.14BEGIN LAT K-0645° FACTORY WYE1+53.31 LAT K-051+00.00 LAT K-06=FL 18"=578.57 CLASS III
18" RCP ON 0.48%
LAT K-06
AT PIPE CL
PR. GRADE
AT PIPE CL
EX. GROUND END LAT K-06CONNECT 18" RCP10' STD. INLET1+43.31 LAT K-06HG 581.91HG 581.81HG 582.01HG 581.91V=0.67 FPS
S=0.00013 FT/FT
C=7.28 CFS
Q100=1.18 CFS
TO BE KILLED
EX. 8" WATER
100 YEAR HGL
FL 571.97+/-
EX. 8" WW
FL 574.87
PROP. 16" WATER
BY OTHERS
RELOCATED
EX. GAS TO BE
585
580
575
590
575
580
585
590
570 570
575
580
585
590
224
11.32 LF 18" RCP 11.31 LF 18" RCP 75 LF 18" RCP
11.31 LF 18" RCP 124.19 LF 24" RCP 43.31 LF 18" RCP
595
575
580
585
590
595
575
580
585
590
595
575
580
585
590
595
585
580
575
590
570
585
580
575
590
570
575
580
585
590
595
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LAT-07.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LAT-07.dgn1:404:43:16 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
LATERAL PROFILES
STORM DRAIN PLAN & PROFILE
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
1+00FL 3'x2'=577.08FL 18"=577.33FL 18"=578.27 CLASS III
18" RCP ON 8.33%45° FACTORY WYE1+58.01 LINE M1+00.00 LAT M-01=END LAT M-01CONNECT 18" RCP10' REC. INLET1+11.29 LAT M-01LAT M-01
AT PIPE CL
PR. GRADE HG 581.56HG 581.38HG 581.69HG 581.58 AT PIPE CL
EX. GROUND
100 YEAR HGL
V=2.42 FPS
S=0.00166 FT/FT
C=30.31 CFS
Q100=4.27 CFS
2+001+00FL 18"=577.28FL 3'x2'=577.03BEGIN LAT M-0245° FACTORY WYE1+34.18 LINE M1+00.00 LAT M-02=LAT M-02
CLASS III18" RCP ON 1.53%FL 18"=578.27FL 18"=578.05END LAT M-02CONNECT 18" RCP10' REC. INLET1+64.54 LAT M-02AT PIPE CL
PR. GRADE
AT PIPE CL
EX. GROUND HG 581.27HG 581.05HG 581.47HG 581.37100 YEAR HGL
V=2.32 FPS
S=0.00154 FT/FT
C=12.99 CFS
Q100=4.10 CFS
TO BE KILLED
EX. 16" WATER
2+001+00FL 3'x2'=577.30FL 18"=577.55FL 18"=579.17FL 18"=578.50LAT M-03
45° FACTORY WYE2+68.58 LINE M1+00.00 LAT M-03=CLASS III18" RCP ON 1.90%END LAT M-03CONNECT 18" RCP10' REC. INLET1+85.05 LAT M-03AT PIPE CL
PR. GRADE
AT PIPE CL
EX. GROUND
HG 582.31HG 582.12HG 582.87HG 582.62V=3.61 FPS
S=0.00370 FT/FT
C=14.47 CFS
Q100=6.37 CFS
100 YEAR HGL
TO BE KILLED
EX. 16" WATER
1+00FL 18"=577.60FL 3'x2'=577.35FL 18"=579.00 CLASS III
18" RCP ON 25.09%45° FACTORY WYE2+95.61 LINE M1+00.00 LAT M-04=END LAT M-04CONNECT 18" RCP10' REC. INLET1+05.59 LAT M-04LAT M-04
AT PIPE CL
PR. GRADE
AT PIPE CL
EX. GROUND HG 582.50HG 582.39V=1.77 FPS
S=0.00090 FT/FT
C=52.60 CFS
Q100=3.13 CFS
HG 582.61HG 582.51100 YEAR HGL
585
580
575
590
575
580
585
590
570
570
570
575
580
585
590
570
575
580
585
590
225
11.29 LF 18" RCP
5.59 LF 18" RCP
64.54 LF 18" RCP 85.05 LF 18" RCP
575
580
585
590
570
575
580
585
590
570
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LAT-08.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LAT-08.dgn1:404:43:19 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
LATERAL PROFILES
STORM DRAIN PLAN & PROFILE
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
2+001+00
LAT C-10
FL 24"=578.28END LAT C-10DROP INLET4'x4' SQUARE1+92.63 LAT C-10FL 24"=575.23FL 24"=576.88CLASS III24" RCP ON 3.29%
AT PIPE CL
PR. GRADE
AT PIPE CL
EX. GROUND
HG 580.27HG 580.14HG 580.54HG 580.401OO YEAR HGL
V=2.66 FPS
S=0.00138 FT/FT
C=41.02 CFS
Q100=8.37 CFS
FL 572.79
PROP. 20" WATER
TO BE KILLED
EX. 8" WATER
TO BE KILLED
EX. 6" WATERBEGIN LAT C-1045° LAT. CONNECT.4+49.23 LINE C1+00.00 LAT C-10=4'X4'=574.23FL LAT C-12
END LAT C-12CONNECT 24" RCP10' REC. INLET1+11.31 LAT C-12FL 24"=577.80 CLASS III
24" RCP ON 22.55%
1+00FL 24"=575.25TO BE KILLED
EX. 6" WATER
AT PIPE CL
PR. GRADE
AT PIPE CL
EX. GROUND HG 580.40HG 580.29HG 580.61HG 580.421OO YEAR HGL
V=3.08 FPS
S=0.00184 FT/FT
C=107.39 CFS
Q100=9.67 CFS
BEGIN LAT C-1245° LAT. CONNECT.4+61.72 LINE C1+00.00 LAT C-12=4'X4'=574.25FL LAT C-13
CLASS III18" RCP ON 5.04%
1+00 2+00END LAT C-13W/2' RIP-RAP APRONTWO-GRATE INLET1+80.29 LAT C-13FL 18"=575.36FL 18"=579.41FL 18"=577.88BY OTHERS
RELOCATED
EX. GAS TO BE
AT PIPE CL
EX. GROUND
AT PIPE CL
PR. GRADE HG 580.04HG 579.94V=0.77 FPS
S=0.00017 FT/FT
C=23.57 CFS
Q100=1.53 CFS
FL 572.87
PROP. 20" WATER
TO BE KILLED
EX. 8" WATERBEGIN LAT C-1360° LAT. CONNECT.3+89.58 LINE C1+00.00 LAT C-13=4'X4'=574.11FL FLOW
PARTIAL
HGL
YEAR
100
1+00
AT PIPE CL
PR. GRADE
LAT C-14
CLASS III
18" RCP ON 18.04%FL 18"=577.38FL 18"=575.34TO BE KILLED
EX. 6" WATER
END LAT C-14CONNECT 18" RCP5 STD. INLET1+11.31 LAT C-14AT PIPE CL
EX. GROUND HG 579.92HG 579.82HG 580.02HG 579.92100 YEAR HGL
V=0.77 FPS
S=0.00017 FT/FT
C=44.60 CFS
Q100=1.36 CFS
BY OTHERS
RELOCATED
CABLE TO BE
EX. TRAFFIC SIGNALBEGIN LAT C-1445° LAT. CONNECT.3+77.92 LINE C1+00.00 LAT C-14=4'X4'=574.09FL LAT C-15
FL 24"=578.361+00 2+00
AT PIPE CL
PR. GRADE END LAT C-15CONNECT 24" RCPSIX-GRATE INLET2+00.28 LAT C-15FL 24"=574.86CLASS III24" RCP ON 3.49%FL 24"=576.61AT PIPE CL
EX. GROUND HG 579.45HG 579.30100 YEAR HGL FLOW
PARTIAL
V=2.65 FPS
S=0.00136 FT/FT
C=42.25 CFS
Q100=8.32 CFS
FL 572.97
PROP. 20" WATER
TO BE KILLED
EX. 8" WATERBEGIN LAT C-1545° LAT. CONNECT.2+63.32 LINE C1+00.00 LAT C-15=4'X4'=573.86FL 1+00
LAT C-16
CLASS III
18" RCP ON 17.17%FL 18"=577.17END LAT C-16CONNECT 18" RCPCL 15' REC. INLET 1+11.48 LAT C-16FL 18"=575.20TO BE KILLED
EX. 6" WATER
AT PIPE CL
EX. GROUND
AT PIPE CL
PR. GRADE HG 579.70HG 579.55HG 580.17HG 579.77100 YEAR HGL
V=4.53 FPS
S=0.00583 FT/FT
C=43.51 CFS
Q100=8.00 CFS
BY OTHERS
RELOCATED
CABLE TO BE
EX. TRAFFIC SIGNAL
4'X4'=573.95FL BEGIN LAT C-1645° LAT. CONNECT.3+11.49 LINE C1+00.00 LAT C-16=226
92.63 LF 24" RCP
585
580
575
590
570
585
580
575
590
570
585
580
575
590
570
585
580
575
590
570
585
580
575
590
570
585
580
575
590
570
585
580
575
590
570
585
580
575
590
570
11.31 LF 24" RCP 80.29 LF 18" RCP
11.31 LF 18" RCP 100.28 LF 24" RCP 11.48 LF 18" RCP
ONLY
REFERENCE
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LAT-09.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USD-LAT-09.dgn1:404:43:21 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
LATERAL PROFILES
STORM DRAIN PLAN & PROFILE
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
2+001+00 FL 24"=579.51FL 24"=579.95CLASS III24" RCP ON 1.71%FL 5'X2'=578.67FL 24"=578.671+74.78 LAT G-031+00.00 LAT G-03=LAT G-03
BEGIN LAT G-03CONNECTION45° LATERAL5+07.99 LINE GEND LAT G-03CONNECT 24" RCP20' REC. INLETAT PIPE CL
EX. GROUND
AT PIPE CL
PR. GRADE HG 582.65HG 582.43HG 582.96HG 582.78100 YEAR HGL
V=3.02 FPS
S=0.00177 FT/FT
C=29.57 CFS
Q100=9.49 CFS
BY OTHERS
RELOCATED
TO BE
EX. FIBER
LAT C-17
FL 24"=579.431+00 2+00
AT PIPE CL
PR. GRADE END LAT C-17CONNECT 24" RCPW/2' RIP-RAP APRON SIX-GRATE INLET 1+97.45 LAT C-17FL 24"=574.74CLASS III24" RCP ON 4.81%FL 24"=577.15AT PIPE CL
EX. GROUND HG 579.03HG 578.83100 YEAR HGL FLOW
PARTIAL
V=3.43 FPS
S=0.00229 FT/FT
C=49.60 CFS
Q100=10.79 CFS
TO BE KILLED
EX. 8" WATER
BY OTHERS
RELOCATED
TO BE
EX. GAS
FL 573.03
PROP. 20" WATERBEGIN LAT C-1745° LAT. CONNECT.2+05.82 LINE C1+00.00 LAT C-17=4'X4'=573.74FL 1+00
LAT C-18
CLASS III
18" RCP ON 25.02%FL 18"=577.84FL 18"=575.01END LAT C-18CONNECT 18" RCP10' REC. INLET 1+11.31 LAT C-18TO BE KILLED
EX. 6" WATER
AT PIPE CL
EX. GROUND
AT PIPE CL
PR. GRADE HG 579.19HG 579.06HG 579.29HG 579.19100 YEAR HGL
V=1.31 FPS
S=0.00049 FT/FT
C=52.52 CFS
Q100=2.32 CFS
BY OTHERS
RELOCATED
CABLE TO BE
EX. TRAFFIC SIGNAL
4'X4'=573.76FL BEGIN LAT C-1845° LAT. CONNECT.2+16.72 LINE C1+00.00 LAT C-18=1+00
CLASS III
18" RCP ON 6.81%FL 18"=578.60AT PIPE CL
PR. GRADE
LAT G-01
END LAT G-01CONNECT 18" RCP15' REC. INLET1+11.30 LAT G-01BEGIN LAT G-01CONNECTION45° LATERAL2+98.20 LINE G1+00.00 LAT G-01=FL 5'x2'=577.58FL 18"=577.83HG 581.70HG 581.51HG 581.96HG 581.73 AT PIPE CL
EX. GROUND
100 YEAR HGL
V=3.44 FPS
S=0.00337 FT/FT
C=27.40 CFS
Q100=6.08 CFS
2+001+00 FL 18"=579.03CLASS III18" RCP ON 1.87%
LAT G-02
END LAT G-02CONNECT 18" RCP10' REC. INLET1+74.78 LAT G-02BEGIN LAT G-02ON TOP OF 5'X2' RCB CONSTRUCT MANHOLE116+82.25 LINE G1+00.00 LAT G-02=FL 5'x2'=577.38FL 18"=577.63FL 18"=578.57AT PIPE CL
EX. GROUND
AT PIPE CL
PR. GRADE HG 581.35HG 581.05HG 581.52HG 581.42100 YEAR HGL
V=1.78 FPS
S=0.00090 FT/FT
C=14.36 CFS
Q100=3.15 CFS
BY OTHERS
RELOCATED
TO BE
EX. FIBER
227
74.78 LF 24" RCP
585
580
575
590
570
585
580
575
590
570
585
580
575
590
570
585
580
575
590
570
585
580
575
590
570
585
580
575
590
570
585
580
575
590
570
74.78 LF 18" RCP
97.45 LF 24" RCP 11.31 LF 18" RCP
11.3 LF 18" RCP
ONLY
REFERENCE
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UDT01.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UDT01.dgn1:404:43:24 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837NTS
E. OF LOOP 288 TO W. OF GRISSOM ROAD
DRAINAGE DETAILS
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
228
SIX GRATE INLET
PLAN VIEW
SECTION D-D
60 LB. RAIL 8'-8" LONG
3/4" X 4" MCH. BOLTS
4'-2 1/4"3'-2 1/4"6"6"8'-10 1/2"4'-2" MIN.3'-8" MIN.12"6"VARIABLED
A
A
6"6"
8'-10 1/2"
7'-10 1/2"
NO SCALE
SMOOTH HARD SURFACE
1/2" MORTAR FINISH, TROWEL TO A
3'-2"2'-6"2'-8"2'-6 1/4"2'-5 3/4"5"
3"5/8"1 3/8"
1 1/8"
2 7/8"4"
LUGS
7/8"1/4"SECTION G-G
TYPE "L" GRATE R-3076
FF
G
G
PLAN VIEW
3/16" CLEARANCE AROUND GRATES
CORNER LUGS 1-1/8" X 1"RR
LLBL5/8"BRHRHRHLHL5/8"
7/8"
1/4"
1 3/8"
20"
18 1/4"
17 3/4"BOTTOM 1" X 1 1/8"SIDE LUGS - TOP 5/8" X 1 1/8"SECTION A-A4'-2" MIN.3'-8" MIN.6"60 LB. RAIL
6"6"3'-2 1/4"
4'-2 1/4"
TO SUIT CONDITIONS
DEPRESSION OF GRATES
1/8"
2 1/2"
2 7/8"
1/8"
1/8"
1 1/8"4"1/4"7/8"FRAME DETAIL
NO SCALE
LUG
CORE FOR 3/4" BOLT
2 7/8"
5/8"
1 1/8"
2 1/2"
2 5/8"
1 1/4"
5/8"
1 1/8"
20-1/4"
18"
SECTION F-F
TYPE "L" GRATE R-3076
3"5"
1/4"
7/8"1/8"D
EACH, AND THE CENTER FRAMES SHALL NOT BE LESS THAN 170 LBS. EACH.
185 LBS., THE DOUBLE GRATE INLET FRAMES SHALL NOT BE LESS THAN 177 LBS.
THE AVERAGE WEIGHT OF SINGLE GRATE INLET FRAME SHALL NOT BE LESS THAN
THE AVERAGE WEIGHT OF ALL GRATE INLETS SHALL NOT BE LESS THAN 153 LBS.
AND "HL".
OMITTING BOTH END FLANGES, ADD BRACKETS "BR" AND "BL" AND CORE HOLES "HR"
TRIPLE GRATE INLETS; USE ONE RIGHT FRAME AND ONE LEFT FRAME AND ONE FRAME
FLANGE ON LINE "R/R" AND ADD BRACKET "BR" AND CORE HOLES "HR". FOR STANDARD
"L/L" AND ADD BRACKET "BL" AND CORE HOLES "HL", ON LEFT FRAME OMIT
FOR STANDARD DOUBLE GRATE INLETS; ON RIGHT FRAME OMIT FLANGE ON LINE
MODIFICATIONS FOR DOUBLE AND TRIPLE GRATE INLETS
6. SEE NEXT SHEET FOR GRATE DETAIL.
FOR STREETS AND ALLEYS.
5. PROVIDE EXPANSION JOINTS AT EDGE OF ALL BLOCKOUTS
SHEET 9010.
4. TYPE "L" GRATES SHALL BE USED AS SHOWN ON
INLET WALLS AND BOTTOM.
3. SEE CITY OF DENTON STANDARD DETAILS FOR STEEL IN
BE INCLUDED IN UNIT PRICE.
2. EXCAVATION, FRAMES, GRATES AND COVERS SHALL
ANGLE OR LOCATION.
1. LATERAL MAY ENTER INLET AT ANY GRADE,
TWO GRATE INLET
PLAN VIEW SECTION B-B
3'-6"4'-2 1/4"3'-2 1/4"6"6"4'-2" MIN.3'-8" MIN.12"6"B
A
A
6"6"
3'-6"
2'-6"
NO SCALE FINISH1/2" MORTARSURFACESMOOTH HARDTROWEL TO AB
60 LB. RAIL 3'-4" LONG
VARIABLE
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UDT02.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UDT02.dgn1:404:43:26 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837NTS
E. OF LOOP 288 TO W. OF GRISSOM ROAD
DRAINAGE DETAILS
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
229
NEENAH FOUNDRY CO. HEAT NO.FLOWFLOWFLOWFLOWNEENAH FOUNDRY CO. HEAT NO.
17"
2Š"3„"3„"3„"2Ž"1‚"1‚"
„"„"
„"„"
1"
•"Ž"Æ’"1Å "•"1"„"Æ’"Å’"3"RÅ’"5°60°â€ž"R1"19•"7-SPACES @ 2†"60°5°â€ž"R3•"R1„"„"75°1…"3‚"8-SPACES @ 3"29Æ’"„"„"
‡"
„"„"
‡"
Æ’"
„"„"
1"1"
17Æ’"
3Æ’"
3Æ’"6"6"
6"6"
•"1•"2•"R - 3076 R - 3065
NO PAINT
ASTM A-48-83 CLASS 35B
MATERIAL - CAST GRAY IRON
TYPE "L" GRATES
R-3076 & R-3065
---
--
-$FILE$$DATE$$TIME$Standard
Division
Bridge
DN:CK:DW:CK:FILE:
JOB
COUNTY
SECT
DIST
REVISIONS
GAF TxDOT TxDOT GAF
HIGHWAY
SHEET NO.
C TxDOT
CONT
ecdstde1.dgn
February 2010
of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:FILE:DATE:EXTENDED CURB DETAILS
CURBS OVER 1'-0" TO 5'-0" TALL
FOR BOX CULVERTS WITH
ECD
CURB QUANTITIES
TABLE OF ESTIMATED
BARS L (#5)
OPTIONAL
3'-8"10"
9"
3
1 "T""C"~ CurbTYPICAL SECTION
1
2
5
H 5
Bars VBars LGENERAL NOTES:
BARS V (#5)
BARS U (#4)
BARS L (#5)10"3
(CY/LF)
2'-0"
2'-6"
3'-0"
3'-6"
4'-0"
4'-6"
5'-0"
0.074
0.093
0.111
0.130
0.148
0.167
0.185
(Lb/LF)
Reinf
Steel
1'-0"0.037
Curb
Height
"C"
2'-8"10"3 7
H 4
"212 1'-6"0.056
10"2"4
U 6
V 6
6
8.9
14.3
15.4
17.7
18.8
21.2
22.2
24.6
25.6
2 "214 12" Max"C" plus 3""211 Spaced at 12" Max
Conc
Used for curbs over 1'-0" to 5'-0"3"Max6
7
8
8
6
1'-0"(Typ)L 3Const jt over 1'-0" to 5'-0"Eq spa at Reinforcing bar dimensions shown are out-to-out of bar.
otherwise.
Cover dimensions are clear dimensions, unless noted
230
grade
Finished
Spaced at 12" Max
Spaced at 12" Max
Spaced at 12" Max
payment.
This Curb is considered as part of the Box Culvert for
T631LS railing, use the T631-CM standard.
of other rail types. For new construction using T631 or
type rails. These details are not suitable for the mounting
These details are suitable for use with PR1, PR2 and PR3
allow for future retrofit of Type T631 or T631LS railing.
These extended curb details have sufficient strength to
Specifications.
Designed according to AASHTO LRFD Bridge Design
Provide Class "C" concrete (f'c = 3,600 psi) minimum for curbs.
Provide Grade 60 reinforcing steel.
3" above the finished grade.
For vehicle safety, top of the curb must not project more than
" cover.41 Adjust reinforcing steel as necessary to provide 1
CONSTRUCTION NOTES:
MATERIAL NOTES:
Quantity includes bars K (when applicable).
intermediate values of curb height, "C".
in table can be interpolated for
linear foot of curb length. The value
information only. Quantities are per
Quantities shown are for Contractor's
closure pour.
for precast box culverts with 3'-0"
Optional bars L are to be used only
maintain clear cover.
length of bars V as necessary to
shown spaced at 12" Max. Adjust
with one bar U and two bars V as
Replace normal culvert curb bars K
maintain 12" Max spacing.
Additional bars H(#4) as required to
clear obstructions.
as shown. Adjust as necessary to
Place normal culvert curb bars H(#4)
necessary to maintain cover.
Place bars L as shown. Tilt hook as
necessary to clear obstructions.
Adjust normal culvert slab bars as
standard for additional details.
slabs less than 7" thick, see SCP-MD
thickness. For precast boxes with
"T" is equal to the culvert top slab
03-16: General Notes added T631-CM.
---
--
-$FILE$$DATE$$TIME$Standard
Division
Bridge
DN:CK:DW:CK:FILE:
JOB
COUNTY
SECT
DIST
REVISIONS
HIGHWAY
SHEET NO.
C TxDOT
CONT
of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:FILE:DATE:4
3'-0" Extend Bars G
(2~Wings)
REINFORCING
TABLE OF WINGWALL
REINFORCING
TOEWALL
TABLE OF
V #4 ~ 1'-0"
P #4 ~ 1'-0"
M #4 4 ~
G #6 ~ 8"
F #4 ~ 1'-0"
E #4 ~ 1'-0"
D #6 ~ 1'-0"
D #6 ~ 1'-0"
Bar Size No. Spa
along this line
based on SL:1 slope
Length of Wings
16'-0" 9'-11" 5'- 0" 3'-11" 1'- 7" #9 6" #7 6" 505.72 2.448 11.47 0.279
15'-6" 9'- 6" 4'-10" 3'- 8" 1'- 6" #9 6" #7 6" 489.52 2.302 11.24 0.253
14'-6" 8'-10" 4'- 5" 3'- 5" 1'- 4" #9 6" #6 6" 432.94 2.046 10.30 0.218
13'-6" 8'- 2" 4'- 0" 3'- 2" 1'- 2" #8 6" #6 6" 348.72 1.804 10.02 0.186
12'-6" 7'- 8" 3'- 9" 2'-11" 1'- 0" #7 6" #6 6" 283.41 1.592 9.74 0.157
11'-6" 7'- 2" 3'- 6" 2'- 8" 11" #6 6" #6 6" 230.13 1.438 9.52 0.140
10'-6" 6'- 5" 3'- 0" 2'- 5" 9" #6 6" #5 6" 196.27 1.234 8.57 0.117
9'-6" 6'- 0" 2'-10" 2'- 2" 9" #5 6" #5 6" 156.93 1.136 8.41 0.110
8'-6" 5'- 6" 2'- 8" 1'-10" 8" #5 6" #5 6" 144.47 1.000 8.13 0.095
8'-0" 5'- 6" 2'- 8" 1'-10" 8" #5 6" #5 6" 139.04 0.962 8.13 0.095
7'-6" 5'- 0" 2'- 3" 1'- 9" 8" #5 1'-0" #5 1'-0" 96.54 0.902 8.07 0.093
7'-0" 5'- 0" 2'- 3" 1'- 9" 8" #5 1'-0" #5 1'-0" 92.15 0.864 8.07 0.093
6'-6" 4'- 4" 2'- 0" 1'- 4" 7" #5 1'-0" #5 1'-0" 85.05 0.768 7.07 0.078
6'-0" 4'- 4" 2'- 0" 1'- 4" 7" #5 1'-0" #5 1'-0" 80.67 0.730 7.07 0.078
5'-6" 3'- 9" 1'- 7" 1'- 2" 7" #4 1'-0" #4 1'-0" 67.46 0.668 6.96 0.075
5'-0" 3'- 9" 1'- 7" 1'- 2" 7" #4 1'-0" #4 1'-0" 63.45 0.632 6.96 0.075
4'-6" 3'- 2" 1'- 2" 1'- 0" 7" #4 1'-0" #4 1'-0" 59.77 0.568 6.85 0.071
4'-0" 3'- 2" 1'- 2" 1'- 0" 7" #4 1'-0" #4 1'-0" 55.77 0.532 6.85 0.071
3'-6" 2'-10" 10" 1'- 0" 7" #4 1'-0" #4 1'-0" 53.98 0.480 6.85 0.071
3'-3" 2'-10" 10" 1'- 0" 7" #4 1'-0" #4 1'-0" 53.32 0.462 6.85 0.071
3'-0" 2'-10" 10" 1'- 0" 7" #4 1'-0" #4 1'-0" 49.98 0.444 6.85 0.071
2'-9" 2'-10" 10" 1'- 0" 7" #4 1'-0" #4 1'-0" 49.31 0.424 6.85 0.071
2'-6" 2'-10" 10" 1'- 0" 7" #4 1'-0" #4 1'-0" 48.64 0.406 6.85 0.071
Jt
Const
3'-0" Extend Bars G6'-0"1'-0"(Showing Wing Reinf)(Showing Wing Reinf)(Showing 30° Skew)
Angle
Skew
less
90°
Angle
Skew
less
90°
PARTIAL ELEVATION - PW-2
Field Bend as needed.
DESIGNER NOTES:
12
13
PARTIAL ELEVATION - PW-1
WING DIMENSION CALCULATIONS:
and U values.
See applicable box culvert standard for S, H, T
0 = Culvert Skew
Usual value is 2:1)
SL:1 = Channel Slope ratio. (Horizontal: 1 Vertical,
N = Number of Culvert Spans
Ltw = Culvert Toewall Length
Lw = Length of Wingwall
Hw = Height of Wingwall
2
2
9
12
13 6" for Hw 4'.
3'-0" for Hw 4'.
is referenced elsewhere in the plans.
1'-0" typical. 2'-0" typical when RAC standard
be allowed for this work.
quantities and no additional compensation will
above requirements. No changes will be made in
Reduce curb heights, if necessary, to meet the
flush with finished grade.
- For structures with bridge rail, build curbs
grade.
cannot project more than 3" above finished
- For structures without bridge rail, curbs
must be met:
For vehicle safety, the following requirements
other than T6, refer to RAC standard.
standard. For structures with traffic rail,
structures with T6 bridge rail, refer to T6-CM
taller than 1'-0", refer to ECD standard. For
with pedestrian rail, bicycle rail or curbs
shown elsewhere in the plans. For structures
0" min to 5'-0" max. Estimated curb heights are
wing.
shown. Provide at least two pair Bars G per
Bars G equally spaced at 8" maximum, place as
Lap Bars M 1'-6" minimum with Bars M .
footing.
Extend Bars E 1'-6" minimum into the wingwall
Fill around weepholes with coarse gravel.
Provide weepholes for Hw = 5'-0" and greater.
Bars D.
Quantities shown do not include weight of
multiply the tabulated values by Lw.
determine estimated quantities for two wings,
Adjust concrete volume for Type PW-2 wings. To
Quantities shown are for two Type PW-1 wings.
For 45° Skew ~ 3"
For 30° Skew ~ 2"
For 15° Skew ~ 1"
At discharge end, chamfer may be Æ’".
Skew Angle = 0°
= (2)(Hw)(Lw) - 1.5 SF for Ty PW-2 and Hw 4'
= (2)(Hw)(Lw) - 6 SF for Ty PW-2 and Hw 4'
= (2)(Hw)(Lw) for Ty PW-1
Total Wingwall Area (Two Wings ~ SF)
Ltw = [(N) (2 U + S) + (N - 1) (0.5')] Cosine 0
For Precast culverts:
Ltw = [(N) (S) + (N + 1) (U)] Cosine 0
For Cast-in-place culverts:
= (Hw - 0.5') (SL) Cosine 0 for Ty PW-2 and Hw 4'
= (Hw - 1') (SL) Cosine 0 for Ty PW-2 and Hw 4'
Lw = (Hw) (SL) Cosine 0 for Ty PW-1
Hw = H + T + C
Formulas: (All values are in Feet)
a railing mounted to the wingwall.
Type PW-2 can only be used for applications without
be used if railing is to be mounted to the wingwall.
Type PW-1 can be used for all applications and must
for the Contractor's information only.
resulting from the formulas given on this sheet are
The quantities for concrete and reinforcing steel
dimensions and information.
See BCS sheet for wingwall type and additional
directed by the Engineer.
reduced or eliminated when founded on solid rock, when
Depth of toewalls for wingwalls and culverts may be
Provide 1 ‚" Min clear cover to reinforcing steel.
and Grade 60 reinforcing steel.
Provide Class "C" Concrete (f'c = 3,600 psi Min)
Design Specifications.
Designed in accordance with AASHTO LRFD Bridge
reinf
Barrel
Walls
Culvert
Barrel Quantities
Limits of Culvert
Walls
Culvert
Reinf
Barrel
Height
Wingwall
Maximum (2~Wings)
of wing
per ft
Quantities
Estimated
Reinforcing
Variable
E #4 ~ 1'-0"
M #4 2 ~
J #4 ~ 1'-0"
Bar Size No Spa
Jt
Const
(1~Toewall)
Toewall
per ft of
Quantities
Estimated
(Roadway Slope)
Finished Grade
SKEWED BOX CULVERTS
DETAILS FOR
NON-SKEWED BOX CULVERTS
DETAILS FOR
Barrel Quantities
Limits of Culvert
Skew
Culvert
HTY
TJ3
EHw2"2"D2D1
V
J
F
Wingwall
1
FV
J3"UU
BARS J 2 BARS J3BARS J
Lw
Lw
90°WSECTION C-C
PLANC
8"3"(Max)1
1
PLAN
LwWLw
D2
J
FFVU3"
J
SECTION C-C
3'-0"
BARS D1
BARS D23'-0"3'-0"11
Dimensions
W X Y
Bars J1 Bars J2
SizeSpa
SizeSpa
Hw
Z
(Lb/Ft)
Reinf Conc
(CY/Ft)
TABLE OF DIMENSIONS & REINFORCING STEEL
2
M2
3"
G
V
F
2"HTX Y
J
Const Jt
WZ 2"J
E M
D
2"2
D
G F
V
ZHwJ2
P
E 3J
SL
1
E C
12'-0"1J
3" weephole
8"
P
M1 M2
2
1 2"E.S.2"(Typ)
Reinf
(Lb/Ft)
Conc
(CY/Ft)
LtwLtw
W 4"
BARS V
(Typ)2'-0"T1
1
2
2
3
2
A B
A B
C
Toe of Slope
Toe of Slope
SECTION A-A SECTION B-B
Wingwall
Wingwall Wingwall
12"
1D UUUSSU U
10
94"TypGENERAL NOTES:
Culvert Skew
(Wings for One Structure End)
1
1
6
1
Z 24"+Hw Z 4"Y 8"++-Z 20"+-Z 20"+Y 36"+Hw Z 4"+-V
8
7
8
5
1
2
3
2
11
Lw
2D D1
D2
1D
D
G F
V
ZHwJ2
P
E 3J
SL
1
E C
2'-0"1J
3" weephole
M1 M2
22"E.S.2"(Typ)
A B
A B
C
4"Typ1
6
7
8
5
Lw
3'-0"1
1
2
3
4
5
6
7
8
10
11
February 2010
TYPES PW-1 AND PW-2
PW
01-12: PW-1 & PW-2.
11-10: Reinforcing Quantities.
pwstde01.dgn GAF CAT GAF TxDOT
BOX CULVERTS
CONCRETE WINGWALLS
WITH PARALLEL WINGS FOR
231
---
--
-$FILE$$DATE$$TIME$Standard
Division
Bridge
DN:CK:DW:CK:FILE:
JOB
COUNTY
SECT
DIST
REVISIONS
HIGHWAY
SHEET NO.
C TxDOT
CONT
of this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:FILE:DATE:1
2
3
4
5
6
7
8
5
3
7
8
4
2
6
1
5
Slab Reinforcing
Culvert Bottom
Reinforcing
Variable
Details
See Corner
Slope
Toe of
this line.
slope along
based on SL:1
Length of Wings
(Roadway Slope)
Finished Grade
16'-0" 8'- 2" 4'- 6" 3'- 0" 1'- 3" #9 6" #6 6" 297.02 1.234
15'-0" 7'- 8" 4'- 0" 3'- 0" 1'- 1" #9 6" #6 6" 283.06 1.068
14'-0" 7'- 2" 3'- 6" 3'- 0" 1'- 0" #8 6" #5 6" 216.78 0.959
13'-0" 6'- 8" 3'- 3" 2'- 9" 11" #7 6" #5 6" 178.80 0.856
12'-0" 6'- 2" 3'- 0" 2'- 6" 9" #7 6" #5 6" 162.29 0.721
11'-0" 5'- 8" 2'- 9" 2'- 3" 8" #6 6" #5 6" 133.65 0.634
10'-0" 5'- 2" 2'- 6" 2'- 0" 8" #5 6" #4 6" 97.25 0.584
9'-0" 4'- 8" 2'- 3" 1'- 9" 8" #4 6" #4 6" 81.49 0.535
8'-0" 4'- 2" 2'- 0" 1'- 6" 8" #5 1'-0" #4 1'-0" 60.19 0.486
7'-0" 3'- 8" 1'- 9" 1'- 3" 7" #4 1'-0" #4 1'-0" 52.77 0.414
6'-0" 3'- 2" 1'- 6" 1'- 0" 7" #4 1'-0" #4 1'-0" 46.42 0.367
5'-6" 3'- 2" 1'- 6" 1'- 0" 7" #4 1'-0" #4 1'-0" 45.75 0.355
5'-0" 3'- 2" 1'- 6" 1'- 0" 7" #4 1'-0" #4 1'-0" 45.09 0.343
4'-6" 3'- 2" 1'- 6" 1'- 0" 7" #4 1'-0" #4 1'-0" 41.75 0.330
4'-0" 2'- 5" 1'- 0" 9" 7" #4 1'-0" #4 1'-0" 38.41 0.285
3'-6" 2'- 5" 1'- 0" 9" 7" #4 1'-0" #4 1'-0" 37.74 0.273
3'-0" 2'- 5" 1'- 0" 9" 7" #4 1'-0" #4 1'-0" 37.07 0.261
2'-6" 2'- 5" 1'- 0" 9" 7" #4 1'-0" #4 1'-0" 33.73 0.248
(2~Wings)
REINFORCING
TABLE OF WINGWALL
Q #4 1 ~
L #4 ~ 1'-6"
Bar Size No. Spa
V #4 ~ 1'-0"
R #5 6 ~
P #4 ~ 1'-0"
M #4 4 ~
G #6 4 ~
F #4 ~ 1'-0"
E #4 ~ 1'-0"
D #5 ~ 1'-0"
Bar Size No. Spa
Hw
Height
Wingwall
Maximum
N = Number of Culvert Spans
Ltw = Culvert Toewall Length
Lw = Length of Wingwall
SL:1 = Side Slope Ratio (Horizontal:1 Vertical)
Hw = Height of Wingwall
QUANTITIES
CULVERT TOEWALL
TABLE OF ESTIMATED
Toewall reinforcing not shown for clarity.)
(Showing reinforcing. Culvert and Culvert
Const Jt
Permiss
and U values.
See applicable box culvert standard for H, S, T,
(2~Wings)
wing length
per ft of
Quantities
Estimated
S S
Lw8"PLAN
X Y
L
Q
R
SECTION B-B
BARS L BARS J
BARS J1
2
2'-0"2'-0"6"
Conc (CY/Ft)Length Varies ~Dimensions
W X Y
SizeSpa
SizeSpa
Z
(Lb/Ft)
Reinf Conc
(CY/Ft)
TABLE OF DIMENSIONS & REINFORCING STEEL
BARS R
2'-0"2'-0"BARS D
4'-0"
BARS VLength Varies ~MZ8"
D
G
R
J
J P
2'-0"6"
X Y
W
V
2
1
F
SECTION A-A
EHw 2"
(Typ)Z (Shortest)Z (Shortest)E
Q
PD
R
WINGWALL
CORNER DETAILS
FOOTING AND TOEWALL
J1 V
J1
RV
2"4"2"L
F MHperpendicular to Rdwy
HwZP
J 4"2'-0"G
1
23"TCConforms to Slope
4"R3"D
SL
1
ET
INSIDE ELEVATION
2'-0" 2.45
0.037
1 2Bars J Bars J
MaxTypA
J or V 12"MaxF or G
B
8"
XY
Const Jt
UUU
Ltw
For Cast-in-place culverts:
Ltw = (N) (S) (N 1) (U)
For Precast culverts:
Ltw = (N) (2U S) (N 1) (0.5')
J2
B
Hw = H T C 0.250'
Lw = (Hw 0.333') (SL)
Wingwall Toewall
Culvert Toewall
A
Total Wingwall Area (Two Wings ~ S.F.)=(Hw 0.333') (Lw)
(Wings for One Structure End) WING DIMENSION CALCULATIONS:
(Showing Dimensions)
2"Z 20"Y 4"Hw Z 4"(Longest)+-Hw Z 4"(Longest)-+++++-
-
++
++-
+
Reinf (Lb/Ft)
Formulas: (All values are in Feet)
W 4"-1'-0"other than T6, refer to RAC standard.
to T6-CM standard. For structures with traffic rail,
ECD standard. For structures with T6 bridge rail, refer
rail, bicycle rail or curbs taller than 1'-0", refer to
elsewhere in the plans. For structures with pedestrian
0" min to 5'-0" max. Estimated curb heights are shown
SECTION B-B will not be required.
riprap is provided, the culvert toewall shown in
riprap, at intervals of approximately 20'. When such
flow, shall extend across the full distance of the
joints or grooved joints, oriented in the direction of
typical riprap reinforcing into the toewall; construction
ground; the toewall shall be reinforced by extending
concrete toewall along all edges adjacent to natural
riprap shall have a 6" wide by 1'-6" deep reinforced
shown on the plans or directed by the Engineer, the
be as required by Item 432, "Riprap". Unless otherwise
riprap shall be constructed. Payment for riprap shall
When shown elsewhere on the plans, a 5" deep concrete
for Contractor's information only.
resulting from the formulas given on this sheet are
The quantities for concrete and reinforcing steel
information.
See BCS sheet for additional dimensions and
or eliminated as directed by the Engineer.
toewalls for culverts and wingwalls may be reduced
When structure is founded on solid rock, depth of
a minimum of 1 ‚" clear cover.
All reinforcing bars shall be adjusted to provide
minimum compressive strength of 3600 psi.
All concrete shall be Class "C" and shall have a
otherwise.
steel reinforcing in riprap concrete unless noted
Material Producer List (MPL) may be used in lieu of
Synthetic fibers listed on the "Fibers for Concrete"
All reinforcing steel shall be Grade 60.
Designed according to AASHTO LRFD Specifications.
Box Culvert.
Extend Bars P 3'-0" minimum into bottom slab of
from that shown as necessary.
flush with Wingwall Toewall. Adjust reinforcing
At Contractor's option, Culvert Toewall may be ended
cover and 4" minimum between bars.
Adjust to fit as necessary to maintain 1 ‚" clear
by Lw.
quantities for two wings multiply the tabulated values
for two wings (one structure end). To determine total
Quantities shown are based on an average wing height
will be allowed for this work.
be made in quantities and no additional compensation
3" projection above finished grade. No changes will
shall be reduced, if necessary, to provide a maximum
For vehicle safety, curb heights and wall heights
GENERAL NOTES:
Recommended values of Slope are: 2:1, 3:1, 4:1, & 6:1.
SW-O
CONCRETE WINGWALLS
WITH STRAIGHT WINGS FOR
0° SKEW BOX CULVERTS
synthetic fibers.
11-10: Add note for
February 2010
sw-0stde.dgn GAF CAT TxDOT GAF
232
---
--
-$FILE$$DATE$$TIME$Standard
Division
Bridgeof this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:FILE:DATE:DN:CK:DW:CK:FILE:
JOB
COUNTY
SECT
DIST
REVISIONS
AES JGD BWH AES
HIGHWAY
SHEET NO.
C TxDOT
CONT
SHEET 1 OF 2Bridge LayoutVariable ~ SeeSee Layout for slope
~crown line. See Roadway DetailsApex and riprap break usually at1'-0"
Min 1'-0"PLAN ~~~
slope
Toe of
See Layout for slope~traffic rail
Showing conc
See elsewhere in plans for rail transition
Approach slab or pavement
SECTION A-A AT CAP
1
1
T
hickness
when required
Filter fabric,
GENERAL NOTES:
See Layout for slope
Ripra
p
ELEVATION
srrstde1-19.dgn
SRR
STONE RIPRAP
See Layout for limits
233
6"
1
6"
1
2"
CAP OPTION A CAP OPTION B
joint sealer
side of wingwalls with
along ends of cap and
Plug ends and seal joint
DETAIL C
A
A
B
B
See Detail C
with joint sealer
or wingwall and seal
Nail flashing to cap
SECTION B-B 1'-6"Thickness1'-0"
abut cap
Face of
(when specified)
Granular material
or as directed by the Engineer
of granular material under riprap only
placed continuously along periphery
Loose graded gravel or crushed stone
protection riprap is greater than 18".
riprap. Omit toewall when thickness of
is located adjacent to limits of stone
Provide toewall when shoulder drain
as required
Toewall,
shoulder drains.
See elsewhere in plans for locations and details of
thickness of riprap specified.
and construction details. See Layout for limits and
Refer to Item 432, "Riprap" for stone size and gradation,
span, box beam, or slab beam bridges.
for beam/slab type bridges and 1'-6" for slab
as directed by the Engineer. Provide 9" Min
Top of cap to top of riprap dimension varies
Protection Thickness
Type R, Type F, CommonslabEdge of bridgeApril 2019
of cap
flashing full length
8"X 18 Gage galvanized
of cap
flashing full length
8"X 18 Gage galvanized
---
--
-$FILE$$DATE$$TIME$Standard
Division
Bridgeof this standard to other formats or for incorrect results or damages resulting from its use.kind is made by TxDOT for any purpose whatsoever. TxDOT assumes no responsibility for the conversion The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of anyDISCLAIMER:FILE:DATE:DN:CK:DW:CK:FILE:
JOB
COUNTY
SECT
DIST
REVISIONS
AES JGD BWH AES
HIGHWAY
SHEET NO.
C TxDOT
CONT
SHEET 2 OF 2
specified
Grout when
1'-6"Min1'-6"
Min
9"
Min
Thickness
2 times
thickness Min
6"Max
embankment
Slope of
perpendicular to slope
Upright axes of stone
embankment
Slope of
specified
Mortar when
Flat side up
embankment
Slope of
Filter fabricembankment
Slope of
specified
Grout when
rock depth)
(more than one
Multiple layers
2
3
2
3
specified
Grout when
embankment
Slope of
SRR
STONE RIPRAP
9"
Min
1'-6"Min1'-6"
Min
9"
Min
1'-6"Min1'-6"
Min
Thickness
Thickness
Thickness
9"
Min
1'-6"Min1'-6"
Min
Thickness
FIGURE 1 ~ TYPE R STONE RIPRAP FIGURE 2 ~ TYPE F STONE RIPRAP FIGURE 3 ~ TYPE F STONE RIPRAP
FIGURE 4 ~ COMMON STONE RIPRAP FIGURE 5 ~ PROTECTION STONE RIPRAP
234
April 2019
bedding material
Filter fabric or
protection
Riprap stone
2:1 Max
T
hickness
ground
Existing
protection
Riprap stone
T
hickness
2:1 Max
bedding material
Filter fabric orground
Existing
ground
Existing
2:1 Max
4
5
5
51:1
4
"Y" x Thickness
Height4
ThicknessLength
MOUNDED TOE
EXTENDED ROCK FILLED TRENCH
PROTECTION STONE RIPRAP TOE OPTIONS
dry or grouted dry or mortared grouted
dry or grouted
Example: Riprap (Stone Protection) XX inch, Thickness = YY inch.
the layout.
List Stone Protection as size (XX inch) and thickness (YY inch) on
values if this option is used.
"Y" and Height need to be defined. See layout or detail sheet for
2 times the riprap thickness.
Minimum toe depth is the larger of the maximum scour depth or
in plans. See Layout for thickness of bedding material.
Provide bedding material instead of filter fabric if shown elsewhere
srrstde1-19.dgn
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CEC01.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CEC01.dgn1:404:43:32 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
EROSION CONTROL PLAN
TO NCTCOG STANDARDS.
& CONTROLS SHALL CONFORM
WATER POLLUTION PREVENTION,
TEMPORARY EROSION, SEDIMENT,
NOTE:
INLET PROTECTION
LIMITS OF DISTURBANCE
EROSION CONTROL LOGS
ENTRANCE/EXIT
STABILIZED CONSTRUCTION
LEGEND:
ROCK CHECK DAM
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
PARKING AREA
S
S
S
LOT 24A
LOOP 288
7-ELEVEN INC
LOT 1
LOT 1
101 N LOOP 288
DENNIS J KOOP
LOT 1
3612 E McKINNEY STREET
McKINNEY BUILDING, LP
VOL. 1029, PG. 281
UTILITY EASEMENT
75' MAINTAINING PUBLIC
CAB. R, PG.
3
2EASEMENT2
0' PUBLI
C UTI
LI
TYVOL. 603, PG. 520
EASEMENT
16' PUBL
IC UT
IL
ITY
CAB. R, PG. 32
EASEMENT
20' PUBLIC UTILITY
CAB. F, PG. 336
ELEC. EASEMENT20' UTILITY &
CAB. F, PG. 336& ELEC.EASEMENT16' UTILITY
VOL. 603, PG. 5
20
EASEMENT
16' PUBL
IC UT
IL
ITY
101 S LOOP 288
INVESTMENT COMPANY
SEJ ASSET MANAGEMENT &
24" RCP
36" RCP
36" RCP
BOX CULVERTEx.
9'
x
5' BOX CULVERTEx.
9'
x
5' BOX CULVERTEx.
9'
x
5' BOX CULVERTEx.
5'
x
4' BOX CULVERTEx.
5'
x
4' BOX CULVERTEx.
5'x4' BOX CULVERTEx.
5'x3' BOX CULVERTEx.
6'
x
3'
24" RCP
24" RCP
24" RCP
24
" RCP
24" RCP 24" RCP
88+00 90+00
91+00
87+00
1
0
0
7
2
+0
0
1
0
0
73+0
0
1
0
0
7
4
+0
0
89+00
24" RCP
4'X2' RCB
235MATCHLINE STA 91+50McKINNEY STREETN LOOP 288S LOOP
2
8
8
EX. R.O.W
DISTURBANCE
LIMITS OF
CL McKINNEY STREET
THIS SHEET = 0.37 ACRES
TOTAL DISTURBED AREA
DISTURBED AREA = 20.65 ACRES
PROJECT TOTAL
EX. R.O.W
EX. R.O.W
(TYP.)
PROTECTION
INSTALL INLET
CONTROL LOGS
INSTALL EROSION
ENTRANCE/EXIT
CONSTRUCTION
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CEC02.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CEC02.dgn1:404:43:34 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
EROSION CONTROL PLAN
TO NCTCOG STANDARDS.
& CONTROLS SHALL CONFORM
WATER POLLUTION PREVENTION,
TEMPORARY EROSION, SEDIMENT,
NOTE:
INLET PROTECTION
LIMITS OF DISTURBANCE
EROSION CONTROL LOGS
ENTRANCE/EXIT
STABILIZED CONSTRUCTION
LEGEND:
ROCK CHECK DAM
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
V
E
PARKING AREA
S
PARKING AREA
3730 E McKINNEY STREET
LISA FONG LEUNG
100 N LOOP 288
100 NORTH LOOP 288, LLC
101 S LOOP 288
DNB INVESTMENTS LTD
101 S LOOP 288
SEJ ASSET MANAGEMENT & INVESTMENT COMPANY
LOOP 288
7-ELEVEN INC
LOT 1
LOT 1
LOT 41LOT 1
LOT 24A
VOL. 603, PG. 520
EASEMENT16' PUBLIC UTILITY
CAB. R, PG. 32
EASEMENT
20' PUBLIC UTILITY
CAB. D, PG. 191
16' UTILITY EASEMENT
VOL. 603, PG. 520
EASEMENT
16' PUBLIC UTILITY
24" RCP 18" RCP
15" RCP
24" RCP
92+00 93+00 94+00 95+00
96+00
D
18" RCP 18" RCP 18" RCP 18"
24" RCP
D
4'X2' RCB RCP30 " 24" RCP
18"
V
S
S S
E McKINNEY STREET
CCD-RLG DENTON I LP
3701 E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
3730 E McKINNEY STREET
LISA FONG LEUNG 191 DUCHESS DRIVE
JBJ/CALDER FUND VII JOINT VENTURE
LOT 1LOT 1
LOT 1
LOT 1
CAB. D, PG. 191
16' UTILITY EASEMENT
CAB. O, PG. 264
EASEMENT
15' PUBLIC UTILITY
CAB. O, PG. 264
10' UTILITY EASEMENT
CAB. O, PG. 264
10' UTILITY EASEMENT
CAB. XX, PG. XX
EASEMENT
PRIVATE DRAINAGE
CAB. X, PG. XX
EASEMENT
8' PUBLIC UTILITY
LOT 1
100 N LOOP 288
LLC
100 NORTH LOOP 288,
CAB. D, PG. 15
20' PUBLIC UTILITY EASEMENT
97+00 98+00 99+00 100+00 101+00
24" RCP
18" RCP
D18"
D
236MATCHLINE STA 91+50McKINNEY STREET
MATCHLINE STA 96+50McKINNEY STREET
MATCHLINE STA 96+50MATCHLINE STA 101+50CL McKINNEY STREET
DISTURBANCE
LIMITS OF
CONTROL LOGS
INSTALL EROSION
FROM STA 96+50-101+50
AREA OF DISTURBANCE 1.40 ACRES
FROM STA 91+50-96+50
AREA OF DISTURBANCE 1.24 ACRES
EX. R.O.W
CL McKINNEY STREET
CONTROL LOGS
INSTALL EROSION
THIS SHEET = 2.64 ACRES
TOTAL DISTURBED AREA
EX. R.O.W
DISTURBANCE
LIMITS OF
DISTURBANCE
LIMITS OF
EX. R.O.W
EX. R.O.W
DISTURBANCE
LIMITS OF
DRIVEDUCHESS (TYP.)
PROTECTION
INSTALL INLET
(TYP.)
PROTECTION
INSTALL INLET
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CEC03.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CEC03.dgn1:404:43:37 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
EROSION CONTROL PLAN
TO NCTCOG STANDARDS.
& CONTROLS SHALL CONFORM
WATER POLLUTION PREVENTION,
TEMPORARY EROSION, SEDIMENT,
NOTE:
INLET PROTECTION
LIMITS OF DISTURBANCE
EROSION CONTROL LOGS
ENTRANCE/EXIT
STABILIZED CONSTRUCTION
LEGEND:
ROCK CHECK DAM
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
DBL. 10" HACKBERRY
18" ELM 6" TREE
TRI 4" TREE
QUAD 6" ELM
DBL. 8" HACKBERRY 6" ELM DBL. 6"/12" HACKBERRY DBL. 6" HACKBERRY DBL. 8" HACKBERRY
4" ELM
6" ELM
DBL. 12" HACKBERRY
DBL. 6" ELM
10" TREE
S
191 DUCHESS DRIVE
JBJ/CALDER FUND VII JOINT VENTURE
E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
STREET
3910 E McKINNEY SCOTTIE ADAMS
LOT 1
LOT 27 LOT 29
LOT 1
CAB. D, PG. 15
20' PUBLIC UTILITY EASEMENT
CAB. O, PG. 264
10' UTILITY EASEMENT
CAB. O, PG. 264
10' UTILITY EASEMENT
CAB. B, PG. 71
25' UTILITY EASEMENT
CAB. B, PG. 7116' UTILITY EASEMENT
15" RCP
102+00 103+00 104+00 105+00
106+00
24" RCP18" RCP18" RCPD18"
RCP36" RCP18"
V
PARKING AREA PARKING AREA PARKING AREA
CONCRETE
PARKING AREA
PARKING AREA
24" HACKBERRYDBL. 12" TREE
24" TREETRI 6" TREE
15" HACKBERRY10" CEDAR
DBL. 10" TREE
DBL. 12" HACKBERRY
S
3912 E McKINNEY STREET
DUNCAN STREET COMMERCIAL LLC
3910 E McKINNEY STREET
SCOTTIE ADAMS
E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
3801 E McKINNEY STREET
ANGEL & GRISELDA ENRIQUEZ
3919/3921 E McKINNEY STREET
NSA PROPERTY HOLDINGS, LLC
3916 E McKINNEY STREET
EDWARD D & SHARYL K DIELEMAN
3918-3920 E McKINNEY STREET
LESLIE A & MICHAEL L ORINGDERFF
LOT 38
LOT 4LOT 3LOT 2LOT 1
LOT 29 LOT 1R
CAB. B, PG. 71
25' UTILITY EASEMENTCAB. B, PG. 71
16' UTILITY EASEMENT
CAB. Y, PG. 289
20' UTILITY EASEMENT
15" RCP
24" RCP
18" RCP
15" RCP
18" RCP 18" RCP
18" RCP
106+00
107+00 108+00 109+00 110+00
36" RCP 24"18"36" RCP
D 18"
30" RCP 24" RCP
18"
18"
R
C
P
18"RCB
4'X4'
RCB
4'X4'
RCB
4'X4'
237MATCHLINE STA 106+00MATCHLINE STA 101+50McKINNEY STREET
MATCHLINE STA 106+00MATCHLINE STA 110+50McKINNEY STREET
EX. R.O.W
EX. R.O.W
EX. R.O.WDISTURBANCE
LIMITS OF
DISTURBANCE
LIMITS OF
DISTURBANCE
LIMITS OF
CL McKINNEY STREET
CL McKINNEY STREET
CONTROL LOGS
INSTALL EROSION
FROM STA 101+50-106+00
AREA OF DISTURBANCE 1.04 ACRES
THIS SHEET = 1.50 ACRES
TOTAL DISTURBED AREA
CONTROL LOGS
INSTALL EROSION
EX. R.O.W
EX. FENCE
EX. FENCE
EX. FENCE
EX. FENCE
(TYP.)
PROTECTION
INSTALL INLET
DISTURBANCE
LIMITS OF
FROM STA 106+00-110+50
AREA OF DISTURBANCE 0.47 ACRES
DONE BY OTHERS TO STA 119+50
CONTRACT, BEGIN WORK TO BE
STA 106+00 END WORK THIS
FROM STA 106+00-110+50
BY OTHERS 0.60 ACRES
AREA OF DISTURBANCE OF WORK
BY OTHERS = 0.60 ACRES
TOTAL DISTURBED AREA OF WORK
REFERENCE ONLY
(TYP.)
PROTECTION
INSTALL INLET
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CEC04.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CEC04.dgn1:404:43:39 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
EROSION CONTROL PLAN
TO NCTCOG STANDARDS.
& CONTROLS SHALL CONFORM
WATER POLLUTION PREVENTION,
TEMPORARY EROSION, SEDIMENT,
NOTE:
INLET PROTECTION
LIMITS OF DISTURBANCE
EROSION CONTROL LOGS
ENTRANCE/EXIT
STABILIZED CONSTRUCTION
LEGEND:
ROCK CHECK DAM
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
CONCRETE
CONCRETE
E
E
PARKING AREA
S
S
S
D
D
S
S
STREET
4001 E McKINNEY
CITY OF DENTON
E McKINNEY STREET
CITY OF DENTON
3922 E McKINNEY STREET
GOEL VENTURES ONE, LLC
3918-3920 E McKINNEY STREET
LESLIE A & MICHAEL L ORINGDERFF
3923 E McKINNEY STREET
DENTON 3919 McKINNEY, LLC
LOT 153
LOT 3LOT 1R
LOT 151 (PT)LOT 5R1
LOT 152
CAB. B, PG. 71
25' UTILITY EASEMENT
CAB. Y, PG. 289
20' UTILITY EASEMENT
CAB. B, PG. 147
16' UTILITY EASEMENT
VOL. 5039, PG. 01970
DRAINAGE EASEMENT
20' PERMANENT
STRIP)
E McKINNEY STREET (200'
VENTURES, LP
BCI REAL ESTATE
2-18" RCP
27" RCP
BOX CULVERT6'x4'BOX CULVERT6'x4'BOX CULVERT6'x4'B
O
X
C
U
L
V
E
R
T
6'x4'10'x4' RCBC111+00 112+00 113+00 114+00 115+00
222+00223+00BOX CULVERT5'x4'18" RCP18"18" RCPD18"BOX CULVERT6'x4'BOX CULVERT6'x4'RCP24" RCP24" D
4'X4' RCBRCB
4'X4'
PARKING AREA
E McKINNEY STREET (200' STRIP)
BCI REAL ESTATE VENTURES, LP BAYLOR UNIVERSITY
4301 E McKINNEY STREET
CITY OF DENTON
4393 E McKINNEY STREET
KENNETH L & GLADYS F STOUT
LOT 151 (PT)LOT 151 (PT)
LOT 159 LOT 161LOT 154
STREET
4515 E McKINNEY
GLADYS F STOUT
KENNETH L &
STREET
4515 E McKINNEY
GLADYS F STOUT
KENNETH L &
15" CMP 15" CMP
116+00 117+00 118+00 119+0018"5'X2' RCB5'X2' RCB 5'X2' RCB
18" RCP
RCP
24"
238MATCHLINE STA 110+50McKINNEY STREET
MATCHLINE STA 115+50MATCHLINE STA 115+50ROADN MAYHI
LL ROADS MAYHI
LL
McKINNEY STREET
LOT 5R1
EX. R.O.W
DISTURBANCE
LIMITS OF
EX. R.O.W
EX. R.O.W
EX. R.O.W
(TYP.) PROTECTION
INSTALL INLET
(TYP.)
PROTECTION
INSTALL INLET
CL McKINNEY STREET
CL McKINNEY STREET
CONTROL LOGS
INSTALL EROSION
THIS SHEET = 0.36 ACRES
TOTAL DISTURBED AREA
MATCHLINE STA 119+00BAYLOR UNIVERSITY
LOT 151 (PT)
FROM STA 117+50-119+00
AREA OF DISTURBANCE 0.36 ACRES
LINK FENCE
EX. CHAIN
EX. FENCE
DISTURBANCE
LIMITS OF
DISTURBANCE
LIMITS OF
EROSION CONTROL PLAN
MAYHILL ROAD
SEE SH. FOR 246
(TYP.)
CONTROL LOGS
INSTALL EROSION
DISTURBANCE
LIMITS OF
REFERENCE ONLY
FROM STA 110+50-115+50
BY OTHERS 0.78 ACRES
AREA OF DISTURBANCE OF WORK
FROM STA 115+50-117+50
BY OTHERS 0.46 ACRES
AREA OF DISTURBANCE OF WORK
BY OTHERS = 1.24 ACRES
TOTAL DISTURBED AREA OF WORK
ENTRANCE/EXIT
CONSTRUCTION
ROCK CHECK DAM
CHECK DAM
ROCK
(TYP.)
PROTECTION
INSTALL INLET
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CEC05.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CEC05.dgn1:404:43:43 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
EROSION CONTROL PLAN
TO NCTCOG STANDARDS.
& CONTROLS SHALL CONFORM
WATER POLLUTION PREVENTION,
TEMPORARY EROSION, SEDIMENT,
NOTE:
INLET PROTECTION
LIMITS OF DISTURBANCE
EROSION CONTROL LOGS
ENTRANCE/EXIT
STABILIZED CONSTRUCTION
LEGEND:
ROCK CHECK DAM
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
PBX
585.19
5/8" IRS W/RANDOM
34
DOC # 99-R0026679
EASEMENT
20' PUBLIC UTILITY
BAYLOR UNIVERSITY
4515 E McKINNEY STREET
KENNETH L & GLADYS F STOUT
LOT 151 (PT)
LOT 161 LOT 162, 163, 164 (OLD DCAD 1P, 1P2, 1R), AC
4663 E McKINNEY STREET
MEMORIAL BAPTIST CHURCH OF DENTON
15" CMP 15" CMP
119+00 120+00 121+00
5'X2' RCB
24" RCP 24" RCP
5'X2' RCB18"
VOL. 5039, PG. 01056
EASEMENT
8' PUBLIC UTILITY
VOL. 5039, PG. 01056
EASEMENTCONSTRUCTION
20' TEMPORARY
VOL. 5039, PG. 01056
EASEMENT
20' PUBLIC UTILITY
BAYLOR UNIVERSITY
4663 E McKINNEY STREETMEMORIAL BAPTIST CHURCH OF DENTON 4673 E McKINNEY STREET
MEMORIAL BAPTIST CHURCH OF DENTON
4683 E McKINNEY STREET
SAYR RESOURCES INC
LOT 151 (PT)
LOT 162, 163, 164 (OLD DCAD 1P, 1P2, 1R), AC
LOT 166 LOT 167
BCI REAL ESTATE VENTURES,LP
LOT 151 (PT)
122+00 123+00 124+00 125+00 126+00
PARKING AREA
PBX
8" HACKBERRY
DBL. 15"/24" PECAN24" PECAN
27" PECANDBL. 18" ELM
15" PECAN
TRI 12" PECAN
30" PECAN
DBL. 8" TREEDBL. 8"/15" TREE
S
18" CMP 15" RCP 15" RCP
5'X2' RCB 36" RCPRCB
5'X3'
McKINNEY STREET
MATCHLINE STA 121+50
F.L. XXXT.C. XXXCL 10' REC. INLETPAV STA 113+99.92, 39.49' RT
239MATCHLINE STA 121+50MATCHLINE STA 126+00McKINNEY STREETMATCHLINE STA 119+00EX. R.O.W
CONTROL LOGS
INSTALL EROSION
CL McKINNEY STREET
EX. R.O.W
FROM STA 121+50-126+00
AREA OF DISTURBANCE 1.06 ACRES
CL McKINNEY STREET
THIS SHEET = 1.66 ACRES
TOTAL DISTURBED AREA
DISTURBANCE
LIMITS OF
DISTURBANCE
LIMITS OF
EX. R.O.W
EX. FENCE
(TYP.)
PROTECTION
INSTALL INLET
CONTROL LOGS
INSTALL EROSION
DISTURBANCE
LIMITS OF
(TYP.)
PROTECTION
INSTALL INLET
FROM STA 119+00-121+50
AREA OF DISTURBANCE 0.60 ACRES
END WORK TO BE DONE BY OTHERS
BEGIN WORK THIS CONTRACT
STA 119+50
PROTECTION
INSTALL INLET
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CEC06.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CEC06.dgn1:404:43:45 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
EROSION CONTROL PLAN
TO NCTCOG STANDARDS.
& CONTROLS SHALL CONFORM
WATER POLLUTION PREVENTION,
TEMPORARY EROSION, SEDIMENT,
NOTE:
INLET PROTECTION
LIMITS OF DISTURBANCE
EROSION CONTROL LOGS
ENTRANCE/EXIT
STABILIZED CONSTRUCTION
LEGEND:
ROCK CHECK DAM
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PBX
36" TREE
36" PECAN
2" TREE
36" PECAN
2" TREE
48" PECAN
DBL. 4"/15" HACKBERRY
6" HACKBERRY
21" CEDARDBL. 15"/24" PECAN
S
586.97
5/8" IRS W/RANDOM
35
BCI REAL ESTATE VENTURES,LP
5001 E McKINNEY STREET
BARBARA McDONALD COBB
5043 E McKINNEY STREET
CHELA DARLINE McDONALD
LOT 151 (PT)
LOT 168 LOT 169
VOL. 5039, PG. 01056
EASEMENTCONSTRUCTION
20' TEMPORARY
VOL. 5039, PG. 01056
EASEMENT
20' PUBLIC UTILITY
VOL. 5039, PG. 01056
EASEMENT
8' PUBLIC UTILITY DOC
#
9
9
-R0
07730
9UTILITY EASEMENT
2
0' PUBLI
C
126+00 127+00 128+00 129+00 130+00
BCI REAL ESTATE VENTURES,LP
5101 E McKINNEY STREET
DENTON ISD
5090 E McKINNEY STREET
EDIBERTO A RODRIGUEZ E McKINNEY STREET
KIM Y PHAM
LOT 151 (PT)
LOT 1R4
LOT 150 LOT 1
CAB. H, PG. 62
20' UTILITY EASEMENT
CAB. E, PG. 330
4' SIDEWALK EASEMENT
130+00 131+00 132+00 133+00 134+00
135+00
CONCRETE
PBX
E
15" RCP
15" RCP
21" RCP 21" RCP 21" RCP
24" RCP
27" RCP
1
5"
R
C
P
24"
R
C
P
27" RCP 27" RCP
2-48" RCP24"
R
CPRCBCEX.9'X6'D
18" RCP18" RCP36"
R
CP
18" RCP
36" RCP
36" RCP18"18" RCPD
36" RCP
RCP
24"
4'x3' RCB
BOX CULVERT3-6'x3'D
1+002+003+00 2+00
18"
30" RCP 24" RCP18"18" RCP36" RCP36" RCP36" RCP24" RCP24"24"18"RCB5'X3'
18" RCP
10+004'X3' RCB
4'X3' RCB MATCHLINE STA 130+00MATCHLINE STA 130+00MATCHLINE STA 135+00MATCHLINE STA 126+00McKINNEY STREET
McKINNEY STREETRYAN WAY240ROADN CARPENTEREX. R.O.W
CONTROL LOGS
INSTALL EROSION
DISTURBANCE
LIMITS OF
DISTURBANCE
LIMITS OF
EX. R.O.W
CONTROL LOGS
INSTALL EROSION
CL McKINNEY STREET
FROM STA 130+00-135+00
AREA OF DISTURBANCE 1.15 ACRES
FROM STA 126+00-130+00
AREA OF DISTURBANCE 0.94 ACRES
THIS SHEET = 2.09 ACRES
TOTAL DISTURBED AREA
EX. FENCE
EX. WOODEN FENCE
EX. WOODEN FENCE
(TYP.)
PROTECTION
INSTALL INLET
(TYP.)
PROTECTION
INSTALL INLET
DISTURBANCE
LIMITS OF EX. R.O.W
247
EROSION CONTROL PLAN
RYAN WAY
SEE SH. FOR
ROCK CHECK DAM
ROCK CHECK DAM
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CEC07.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CEC07.dgn1:404:43:47 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
EROSION CONTROL PLAN
TO NCTCOG STANDARDS.
& CONTROLS SHALL CONFORM
WATER POLLUTION PREVENTION,
TEMPORARY EROSION, SEDIMENT,
NOTE:
INLET PROTECTION
LIMITS OF DISTURBANCE
EROSION CONTROL LOGS
ENTRANCE/EXIT
STABILIZED CONSTRUCTION
LEGEND:
ROCK CHECK DAM
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
587.025/8" IRS W/RANDOM36
5101 E McKINNEY STREET
DENTON ISD
LOT 1R4
E McKINNEY STREET
KIM Y PHAM
LOT 1
CAB. H, PG. 6220' UTILITY EASEMENT
CAB. E, PG. 330
4' SIDEWALK EASEMENT
135+00 136+00 137+00 138+00
139+00
5101 E McKINNEY STREET
DENTON ISD
E McKINNEY STREET
KIM Y PHAM E McKINNEY STREET
KIM Y PHAM
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
LOT 1R4
LOT 1
LOT 1, BLOCK A
LOT 1, BLOCK B
CAB. H, PG. 62
20' UTILITY EASEMENT
CAB. H, PG. 62
16' UTILITY EASEMENT
CAB. E, PG. 60
16' UTILITY EASEMENTCAB.
H,
P
G.
6
2
1
6' UTI
LI
T
Y
E
AS
E
ME
N
T
CAB. E, PG. 330
EASEMENT
4' SIDEWALK
CAB. E, PG. 330
4' SIDEWALK EASEMENT
139+00 140+00 141+00 142+00 143+00
V
E
ES
592.87
5/8" IRS W/RANDOM
37
24" RCP
18" RCP
24" RCP
18" RCP
D7+00 8+00 9+0018"24" RCP
18"RCP
MATCHLINE STA 143+50MATCHLINE STA 139+00MATCHLINE STA 135+00MATCHLINE STA 139+00McKINNEY STREET
McKINNEY STREET
GLENNGARY WAY241
CL McKINNEY STREET
CL McKINNEY STREET
EX. R.O.W
EX. R.O.W
DISTURBANCE
LIMITS OF
DISTURBANCE
LIMITS OF
FROM STA 135+00-139+00
AREA OF DISTURBANCE 0.96 ACRES
FROM STA 139+00-143+50
AREA OF DISTURBANCE 1.09 ACRES
THIS SHEET = 2.05 ACRES
TOTAL DISTURBED AREA
(TYP.)
PROTECTION
INSTALL INLET
CONTROL LOGS
INSTALL EROSION
CONTROL LOGS
INSTALL EROSION
EX. WOODEN FENCE
(TYP.)
PROTECTION
INSTALL INLET
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CEC08.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CEC08.dgn1:404:43:49 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
EROSION CONTROL PLAN
TO NCTCOG STANDARDS.
& CONTROLS SHALL CONFORM
WATER POLLUTION PREVENTION,
TEMPORARY EROSION, SEDIMENT,
NOTE:
INLET PROTECTION
LIMITS OF DISTURBANCE
EROSION CONTROL LOGS
ENTRANCE/EXIT
STABILIZED CONSTRUCTION
LEGEND:
ROCK CHECK DAM
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
S
E McKINNEY STREET
KIM Y PHAM
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
E McKINNEY STREET
ATMOS ENERGY CORP
LOT 1
LOT 147BLOT 1, BLOCK B
CAB. E, PG. 60
16' UTILITY EASEMENT
CAB. E, PG. 330
EASEMENT
4' SIDEWALK
144+00 145+00 146+00 147+00 148+00
E McKINNEY STREET
ATMOS ENERGY CORP
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
LOT 147B
LOT 1 LOT 1
CAB. E, PG. 60
16' UTILITY EASEMENT
CAB. E, PG. 60
16' UTILITY EASEMENT
148+00 149+00 150+00 151+00 152+00
CONCRETE E
S S
S
582.48
X CUT SET
38
18" RCP
18" RCP BOX CULVERT4.35'x4'3
-
3
6
" CMPRCBEX.3-6'x3'D18"RCP18"18" RCP
4+00 2+003+0018" RCP 18" RCP
18"24" RCP 24" RCP 18" RCP24" RCP24" RCP18" RCPCULVERTBOX 3-7'x3'MATCHLINE STA 143+50MATCHLINE STA 148+00MATCHLINE STA 152+50MATCHLINE STA 148+00McKINNEY STREET
242
12" WWMcKINNEY STREET
FROM STA 148+00-152+50
AREA OF DISTURBANCE 1.06 ACRES
FROM STA 143+50-148+00
AREA OF DISTURBANCE 1.03 ACRES
THIS SHEET = 2.09 ACRES
TOTAL DISTURBED AREA
EX. R.O.W
EX. R.O.W
DISTURBANCE
LIMITS OF
DISTURBANCE
LIMITS OF
CONTROL LOGS
INSTALL EROSION
S FORK DRIVECL McKINNEY STREET
CL McKINNEY STREET
CONTROL LOGS
INSTALL EROSION
LINK FENCE
EX. CHAIN
LINK FENCE
EX. CHAIN
LINK FENCE
EX. CHAIN
EX. WOODEN FENCE
(TYP.)
PROTECTION
INSTALL INLET
EX. R.O.W
DISTURBANCE
LIMITS OF
(TYP.)
PROTECTION
INSTALL INLET
ROCK CHECK DAM
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CEC09.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CEC09.dgn1:404:43:52 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
EROSION CONTROL PLAN
TO NCTCOG STANDARDS.
& CONTROLS SHALL CONFORM
WATER POLLUTION PREVENTION,
TEMPORARY EROSION, SEDIMENT,
NOTE:
INLET PROTECTION
LIMITS OF DISTURBANCE
EROSION CONTROL LOGS
ENTRANCE/EXIT
STABILIZED CONSTRUCTION
LEGEND:
ROCK CHECK DAM
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
S
E McKINNEY STREET
ATMOS ENERGY CORP
LOT 147A
E McKINNEY STREET
ATMOS ENERGY CORP
LOT 147B
LOT 1
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
CAB. E, PG. 60
16' UTILITY EASEMENT
153+00
154+00 155+00 156+00
157+00
E McKINNEY STREET
ATMOS ENERGY CORP
E McKINNEY STREET & TRINITY ROAD
THE WOODLANDS ON McKINNEY STREET LLC
K
O
R
N
U
P
A
U
L
& WE
N TS
AI
LOT 147A
LOT 143, 144L
O
T 108
LOT 1
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
CAB. E, PG. 60
16' UTILITY EASEMENT
V
OL. 990, P
G.640
15'
UTILIT
Y E
AS
E
ME
N
T
157+00 158+00 159+00 160+00 161+00
585.97PK NAIL SET39
DD18" RCP3'x2' RCB
18" RCP
18"MATCHLINE STA 152+50MATCHLINE STA 157+00MATCHLINE STA 161+50MATCHLINE STA 157+00McKINNEY STREET
McKINNEY STREET
243FROM STA 157+00-161+50
AREA OF DISTURBANCE 1.03 ACRES
FROM STA 152+00-157+00
AREA OF DISTURBANCE 1.03 ACRES
THIS SHEET = 2.06 ACRES
TOTAL DISTURBED AREA
CL McKINNEY STREET
CL McKINNEY STREET
EX. R.O.W
EX. R.O.WDISTURBANCE
LIMITS OF
DISTURBANCE
LIMITS OF
CONTROL LOGS
INSTALL EROSION
EX. WOODEN FENCE
EX. WOODEN FENCE
LINK FENCE
EX. CHAIN
EX. FENCE
LINK FENCE
EX. CHAIN
(TYP.)
PROTECTION
INSTALL INLET
CONTROL LOGS
INSTALL EROSION
DISTURBANCE
LIMITS OF EX. R.O.W
DISTURBANCE
LIMITS OF
EX. R.O.W
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CEC10.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CEC10.dgn1:404:43:54 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
EROSION CONTROL PLAN
TO NCTCOG STANDARDS.
& CONTROLS SHALL CONFORM
WATER POLLUTION PREVENTION,
TEMPORARY EROSION, SEDIMENT,
NOTE:
INLET PROTECTION
LIMITS OF DISTURBANCE
EROSION CONTROL LOGS
ENTRANCE/EXIT
STABILIZED CONSTRUCTION
LEGEND:
ROCK CHECK DAM
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
D
E McKINNEY STREET & TRINITY ROAD
THE WOODLANDS ON McKINNEY STREET LLC
E McKINNEY STREET
ATMOS ENERGY CORP
LOT 143, 144
LOT 147A LOT 146
E McKINNEY STREET
ATMOS ENERGY CORP
162+00 163+00 164+00 165+00 166+00
E McKINNEY STREET & TRINITY ROAD
THE WOODLANDS ON McKINNEY STREET LLC
E McKINNEY STREET
ATMOS ENERGY CORP
LOT 146
LOT 145
LOT 143, 144
TRINITY ROAD
E McKINNEY STREET &
McKINNEY STREET LLC
THE WOODLANDS ON
166+00 167+00 168+00 169+00 170+00
594.11
5/8" IRS W/RANDOM
40
DMATCHLINE STA 161+50MATCHLINE STA 166+00MATCHLINE STA 170+50MATCHLINE STA 166+00244
McKINNEY STREET
McKINNEY STREET Mc
KI
NNEY STREETFROM STA 166+00-170+50
AREA OF DISTURBANCE 1.03 ACRES
FROM STA 161+50-166+00
AREA OF DISTURBANCE 1.03 ACRES
THIS SHEET = 2.06 ACRES
TOTAL DISTURBED AREA
EX. R.O.W
EX. R.O.W
DISTURBANCE
LIMITS OF
DISTURBANCE
LIMITS OF
CONTROL LOGS
INSTALL EROSION
CONTROL LOGS
INSTALL EROSION
CL McKINNEY STREET
CL McKINNEY STREET
EX. FENCE
EX. FENCE
LINK FENCE
EX. CHAIN
DISTURBANCE
LIMITS OF EX. R.O.W
DISTURBANCE
LIMITS OF EX. R.O.W
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CEC11.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CEC11.dgn1:404:43:56 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
EROSION CONTROL PLAN
TO NCTCOG STANDARDS.
& CONTROLS SHALL CONFORM
WATER POLLUTION PREVENTION,
TEMPORARY EROSION, SEDIMENT,
NOTE:
INLET PROTECTION
LIMITS OF DISTURBANCE
EROSION CONTROL LOGS
ENTRANCE/EXIT
STABILIZED CONSTRUCTION
LEGEND:
ROCK CHECK DAM
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
S
S
S
587.06
5/8" IRS W/RANDOM
41
D
E McKINNEY STREET
ATMOS ENERGY CORP
E McKINNEY STREET & TRINITY ROAD
THE WOODLANDS ON McKINNEY STREET LLC
LOT 146
LOT 143, 144 LOT 143, 144
TRINITY ROAD
E McKINNEY STREET &
McKINNEY STREET LLC
THE WOODLANDS ON
TRINITY ROAD
E McKINNEY STREET &
ON McKINNEY STREET LLC
THE WOODLANDS
VOL. 695, PG. 351
16' UTILITY EASEMENT
VOL. XX, PG. XX
UTILITY EASEMENT
VARIABLE WIDTH
VOL. XX, PG. XX
25' UTILITY EASEMENT
VOL. XX, PG. XX
16' UTILITY EASEMENT
VOL. XX, PG. XX
EASEMENT
30' TEMPORARY CONSTRUCTION
171+00 172+00 173+00 174+00 175+00
MATCHLINE STA 170+50McKINNEY STREET
245
EX. R.O.W
DISTURBANCE
LIMITS OF
CONTROL LOGS
INSTALL EROSION
CL McKINNEY STREET
THIS SHEET = 0.70 ACRES
TOTAL DISTURBED AREA
EX. FENCE
LINK FENCE
EX. CHAIN
ENTRANCE/EXIT
CONSTRUCTION
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CEC12.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CEC12.dgn1:404:43:58 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
EROSION CONTROL PLAN
TO NCTCOG STANDARDS.
& CONTROLS SHALL CONFORM
WATER POLLUTION PREVENTION,
TEMPORARY EROSION, SEDIMENT,
NOTE:
INLET PROTECTION
LIMITS OF DISTURBANCE
EROSION CONTROL LOGS
ENTRANCE/EXIT
STABILIZED CONSTRUCTION
LEGEND:
ROCK CHECK DAM
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
CONCRETESSDDDDS3922 E McKINNEY STREET
GOEL VENTURES ONE, LLC
3923 E McKINNEY STREET
DENTON 3919 McKINNEY, LLC
E McKINNEY STREET (200' STRIP)
BCI REAL ESTATE VENTURES, LP
1516 E McKINNEY STREET
TALOUKIE BROS ENT INC
LOT 5R1 LOT 3
LOT 152
LOT 151 (PT)
LOT 5R2
4001 E McKINNEY STREET
CITY OF DENTON
CAB. B, PG. 71
25' UTILITY EASEMENT
CAB. Y, PG. 289
20' UTILITY EASEMENT
CAB. B, PG. 147
16' UTILITY EASEMENT
27" RCPBOX CULVERT
6'x4'
BOX CULVERT
6'x4'
BOX CULVERT6'x4'18" RCP 18" RCP 24" RCPBOX CULVERT6'x4'
BOX CULVERT
8'x4'
18" RCP
18" RCP18" RCP
BOX CULVERT
6'x4'
BOX CULVERT
8'x4'112+00113+00222+00
221+00
220+00
223+00 224+00 225+00DBOX CULVERT6'x4'BOX CULVERT6'x4'4'X4' RCBMcKINNEY STREETS MAYHILL ROAD
N MAYHILL ROAD
246
CL McKINNEY STREET
CL MAYHILL ROAD
EX. R.O.W
EX. R.O.W
DISTURBANCE
LIMITS OF
DISTURBANCE
LIMITS OF
CONTROL LOGS
INSTALL EROSION
(TYP.)
PROTECTION
INSTALL INLET
(TYP.)
PROTECTION
INSTALL INLET
238
EROSION CONTROL PLAN
McKINNEY STREET
SEE SH. FOR
BY OTHERS = 1.07 ACRES
TOTAL DISTURBED AREA OF WORK
REFERENCE ONLY
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CEC13.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CEC13.dgn1:404:44:02 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
EROSION CONTROL PLAN
TO NCTCOG STANDARDS.
& CONTROLS SHALL CONFORM
WATER POLLUTION PREVENTION,
TEMPORARY EROSION, SEDIMENT,
NOTE:
INLET PROTECTION
LIMITS OF DISTURBANCE
EROSION CONTROL LOGS
ENTRANCE/EXIT
STABILIZED CONSTRUCTION
LEGEND:
ROCK CHECK DAM
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL 2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PBX
E
3
6
"
T
R
E
EBCI REAL ESTATE VENTURES,LP
5090 E McKINNEY STREET
EDIBERTO A RODRIGUEZ
5101 E McKINNEY STREET
DENTON ISD
LOT 169
LOT 151 (PT)
LOT 150
LOT 1R4
5043 E McKINNEY STREET
CHELA DARLINE McDONALD
CAB. H, PG. 62
20' UTILITY EASEMENT
PC 129+61.61
130+00131+00132+0018"36" RCP36" RCP36" RCP24" RCP24"24"4'X3'
RCB4'X3'
RCBMcKINNEY STREET247
RYAN WAY
THIS SHEET = 0.14 ACRES
TOTAL DISTURBED AREA
EX. WOODEN FENCE
DISTURBANCE
LIMITS OF
EX. R.O.W
(TYP.)
PROTECTION
INSTALL INLET
(TYP.)
PROTECTION
INSTALL INLET
240
EROSION CONTROL PLAN
McKINNEY STREET
SEE SH. FOR
SHEET 1 OF 3
SECTION C-C
STAKE
FLOW
A A
1'
B
B
R.O.W.
BACK OF CURB
FLOW
DISTURBED AREA
LIP OF GUTTER2'1'C
C
R.O.W.
FLOW2'GENERAL NOTES:+-+-2"•"1"R REBAR STAKE DETAIL
#3 BAR
CONTROL LOGS SPECIFIED IN PLANS
DIAMETER MEASUREMENTS OF EROSION
DISTURBED AREA
BACK OF CURB
LIP OF GUTTER
PLAN VIEW PLAN VIEW
CL-ROW
CL-BOC
CL-D
PLAN VIEW
1' MIN.ENGINEER.
AS DIRECTED BY THE
(4' MAX. SPACING), OR
NEEDED TO SECURE LOG
ADDITIONAL POINTS AS
AT EACH END, AND AT
SIDE AT THE CENTER,
STAKE LOG ON DOWNHILL
ENGINEER.
OR AS DIRECTED BY THE
AS NEEDED TO SECURE LOG,
LOG AT 8' (ON CENTER) MAX.
STAKE ON DOWNHILL SIDE OF
ENGINEER.
OR AS DIRECTED BY THE
AS NEEDED TO SECURE LOG,
LOG AT 8' (ON CENTER) MAX.
STAKE ON DOWNHILL SIDE OF
EROSION CONTROL LOG DAM
STAKE
SECTION B-B
CONTROL LOG
TEMP. EROSION
1' (TYP.)
SECTION A-A
EROSION CONTROL LOG AT EDGE OF RIGHT-OF-WAY
EROSION CONTROL LOG AT BACK OF CURB
THE ENGINEER.
OR AS DIRECTED BY
(4' MAX. SPACING),
NEEDED TO SECURE LOG
ADDITIONAL POINTS AS
AT EACH END, AND AT
SIDE AT THE CENTER,
STAKE LOG ON DOWNHILL
CONTROL LOG
UNDER EROSION
COMPOST CRADLE
DIRECTED
STAKE AS
OF LOG TO
SECURE END
CONTROL LOG
TEMP. EROSION
CONTROL LOG
TEMP. EROSION
R.O.W.
CONTROL LOG
UNDER EROSION
COMPOST CRADLE
CONTROL LOG
TEMP. EROSION R.O.W.
CONTROL LOG
UNDER EROSION
COMPOST CRADLE
DIRECTED
STAKE AS
OF LOG TO
SECURE END
DIRECTED
STAKE AS
OF LOG TO
SECURE END
CONTROL LOG
TEMP. EROSION
LOG
CONTROL
EROSION
TEMPORARY
(TYP.)
1'
CL-GI
RUNOFF EVENTS
STAKES FOR HEAVY
ADDITIONAL UPSTREAM
RUNOFF EVENTS
STAKES FOR HEAVY
ADDITIONAL UPSTREAM
RUNOFF EVENTS
STAKES FOR HEAVY
ADDITIONAL UPSTREAM
RUNOFF EVENTS
STAKES FOR HEAVY
ADDITIONAL UPSTREAM
LOG FROM FOLDING IN ON ITSELF.
UPSTREAM STAKES MAY BE NECESSARY TO KEEP
FOR HEAVY RUNOFF EVENTS, ADDITIONAL10.
LOG.
TO PREVENT RUNOFF FROM FLOWING AROUND THE
TURN THE ENDS OF EACH ROW OF LOGS UPSLOPE9.
SIZE TO HOLD LOGS IN PLACE.
ON TOP OF LOGS & SHALL BE OF SUFFICIENT
SANDBAGS USED AS ANCHORS SHALL BE PLACED8.
WILL NOT BE PAID FOR SEPARATELY.
COMPOST CRADLE MATERIAL IS INCIDENTAL &7.
MESH.
DO NOT PLACE STAKES THROUGH CONTAINMENT 6.
THE ENGINEER.
2" PROTRUDES ABOVE LOG, OR AS DIRECTED BY
#3 REBAR, 2'-4' LONG, EMBEDDED SUCH THAT
STAKES SHALL BE 2" X 2" WOOD OR5.
DEFORMATION.
SPECIFIED IN THE PLANS WITHOUT EXCESSIVE
TO ACHIEVE THE MINIMUM COMPACTED DIAMETER
FILL LOGS WITH SUFFICIENT FILTER MATERIAL4.
USE RECYCLABLE CONTAINMENT MESH.
SYSTEM. FOR TEMPORARY INSTALLATIONS,
REMAIN IN PLACE AS PART OF A VEGETATIVE
CONTAINMENT MESH ONLY WHERE LOG WILL
BIODEGRADABLE OR PHOTODEGRADABLE
UNLESS OTHERWISE DIRECTED, USE3.
THE PURPOSE INTENDED.
RECOMMENDATIONS AND AS REQUIRED FOR
BE IN ACCORDANCE WITH MANUFACTURER'S
LENGTHS OF EROSION CONTROL LOGS SHALL2.
ENGINEER.
RECOMMENDATIONS, OR AS DIRECTED BY THE
IN ACCORDANCE WITH MANFACTURER'S
EROSION CONTROL LOGS SHALL BE INSTALLED1.
CL-D
CL-BOC
CL-ROW
CL-SST
CL-SSL
CL-DI
CL-CI
EROSION CONTROL LOG DAM
EROSION CONTROL LOG AT DROP INLET
EROSION CONTROL LOG AT CURB INLET
EROSION CONTROL LOG AT CURB & GRATE INLET
LEGEND
EROSION CONTROL LOG AT EDGE OF RIGHT-OF-WAY
STAKE AND TRENCHING ANCHORING
EROSION CONTROL LOGS ON SLOPES
STAKE AND LASHING ANCHORING
EROSION CONTROL LOGS ON SLOPES
EROSION CONTROL LOG AT BACK OF CURB
DN:FILE:
---
-
JOB
COUNTY
SECT
DIST
REVISIONS
-
HIGHWAY
-
SHEET NO.
CONT
EC(9)-16
Standard
Division
Design
JULY 2016C TxDOT:
TxDOT
POLLUTION CONTROL MEASURES
SEDIMENT AND WATER
TEMPORARY EROSION,
ec916
248
EROSION CONTROL LOG
CK:DW:KM LSLS/PT CK:TxDOT assumes no responsibility for the conversion of this standard to other formats or for incorrect results or damages resulting from its use.The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of any kind is made by TxDOT for any purpose whatsoever. DISCLAIMER:DIAMETER
COMPACTED
MINIMUM
DIAMETER
COMPACTED
MINIMUM
FILE:DATE:$FILE$$DATE$SEDIMENT BASIN & TRAP USAGE GUIDELINES
3. Just before the drainage enters a water course
4. Just before the drainage leaves the right of way
1. Within drainage ditches spaced as needed or min. 500' on center
sediment out of runoff draining from an unstabilized area.
2. Immediately preceding ditch inlets or drain inlets
limits where drainage flows away from the project.
5. Just before the drainage leaves the construction
will not be paid for separately.
Cleaning and removal of accumulated sediment deposits is incidental and
An erosion control log sediment trap may be used to filter
Log Traps: The drainage area for a sediment trap should not exceed
5 acres. The trap capacity should be 1800 CF/Acre (0.5" over
the drainage area).
Control logs should be placed in the following locations:
The logs should be cleaned when the sediment has accumulated to a
depth of 1/2 the log diameter.
SHEET 2 OF 3
TOE OF SLOPE
5'-0" ABOVE
STAGGER JOINTS
5'-0" TO 10'-0"
STAGGER JOINTS
5'-0" TO 10'-0"
STAKE NOTCH DETAIL4"STAKE
ROPE
NOTCH
•" x •"
EROSION CONTROL LOG SPACING TABLE
6"8"12"
2:1
3:1
1'2'
STAKE
18"
TOP OF SLOPE
6' BELOW
TOP OF SLOPE
EROSION CONTROL LOG
TOE OF SLOPE
5'-0" ABOVE
TOP OF SLOPE
6' BELOW
TOP OF SLOPE
EROSION CONTROL LOG
2' MINIMUM
SLOPE
1:1 OR STEEPER
4:1 OR FLATTER
LOG DIAMETER
TRENCH DEPTH TABLE
LOG DIAMETER DEPTH
6"
8"
2"
3"
4"12" MINIMUM2" MINIMUM
6" DIAMETER
EROSION CONTROL LOG
SLOPE
ROPE
NOTCH Typ
STAKE
2' TO 4' LONG.
or #3 REBAR,
2" x 2" WOOD
CONTROL LOG.
SIDE OF EROSION
MATERIAL ON UPHILL
PLACE EXCAVATED
12" MI
NI
MU
MHARD, ROCKY SOILS- ADJUST ROWS FARTHER APART
SOFT, LOAMY SOILS-ADJUST ROWS CLOSER TOGETHER;
* ADJUSTMENTS CAN BE MADE FOR SOIL TYPE:
2'
1'
OVERLAP
2'
LOG
CONTROL
EROSION
LOG
CONTROL
EROSION
TOE OF SLOPE TOE OF SLOPE
12"
18"5"MIN.2"DISTURBED AREA
DIRECTED
STAKE AS
OF LOG TO
SECURE END
5'
END SECTION RAP DETAIL
UNDERCUTTING.
SOIL TO PREVENT
NOTE: COMPACT EXCAVATED
1'
2' MINIMUM 2'
OVERLAP LOG
CONTROL
EROSION
EVENTS
HEAVY RUNOFF
NEEDED FOR
STAKING IF
ADDITIONAL
4'
TABLE BELOW)
SPACING
CONTROL LOG
(SEE EROSION
LOG SPACING
TABLE BELOW)
SPACING
CONTROL LOG
(SEE EROSION
LOG SPACING
5'10'15'20'
10'20'30'40'
15'30'45'60'
20'40'60'80'
STAKE AND TRENCHING ANCHORING DETAIL
STAKE AND LASHING ANCHORING DETAIL
CL-SST
CL-SSL
CL-SSLCL-SST
STAKE AND TRENCHING ANCHORING
EROSION CONTROL LOGS ON SLOPES
STAKE AND LASHING ANCHORING
EROSION CONTROL LOGS ON SLOPES
DN:FILE:
---
-
JOB
COUNTY
SECT
DIST
REVISIONS
-
HIGHWAY
-
SHEET NO.
CONT
EC(9)-16
Standard
Division
Design
JULY 2016C TxDOT:
249
TxDOT
POLLUTION CONTROL MEASURES
SEDIMENT AND WATER
TEMPORARY EROSION,
EROSION CONTROL LOG
ec116 CK:DW:KM LSLS/PT CK:TxDOT assumes no responsibility for the conversion of this standard to other formats or for incorrect results or damages resulting from its use.The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of any kind is made by TxDOT for any purpose whatsoever. DISCLAIMER:FILE:DATE:$FILE$$DATE$
24"24" MINIMUM
OVERLAP ENDS TIGHTLY
DIRECTED
STAKE AS
OF LOG TO
SECURE END
CONTROL LOG
TEMP. EROSION
Flow
ROADWAYFlow
Flo
wFlo
wCURB
FLOWFLOW
CONTROL LOG
TEMP. EROSION
EROSION CONTROL LOG
AREA DRAIN INLETS WITH
DRAINAGE ACCESS TO
COMPLETELY SURROUND
Flow
6" CURB
ROADWAYFlow
Flo
wFl
o
wCURB INLET
EXTENSION
INLET
MIN.
2 FT
MIN.
2 FT
GRATE INLET
CURB AND
EROSION CONTROL LOG AT DROP INLET
CL-DI
CONTROL LOG
TEMP. EROSION
BB
24"-30"
SHEET 3 OF 3
IN PLACE (TYPICAL)
LOG AS NEEDED TO HOLD
ON DOWNHILL SIDE OF
STAKE OR USE SANDBAGS
SANDBAG
SANDBAG
EROSION CONTROL LOG AT CURB & GRADE INLET
NEEDED OR SANDBAGS TO HOLD IN PLACE.
LOGS, AT ENDS, MIDPOINT, & AS
USE STAKES ON DOWNSTREAM SIDE OF
TEMPORARY EROSION CONTROL LOG
NEEDED OR SANDBAGS TO HOLD IN PLACE.
LOGS, AT ENDS, MIDPOINT, & AS
USE STAKES ON DOWNSTREAM SIDE OF
2 SAND BAGS
2 SAND BAGS
STORM SEWER SYSTEM IS NOT FULLY FUNCTIONAL.
TRAFFIC OR FLOOD THE ROADWAY OR WHEN THE
SHOULD ONLY BE USED IF THEY WILL NOT IMPEDE
EROSION CONTROL LOGS USED AT CURB INLETS
NOTE:
6"-8"
CL-GI
DN:FILE:
---
-
JOB
COUNTY
SECT
DIST
REVISIONS
-
HIGHWAY
-
SHEET NO.
CONT
EC(9)-16
Standard
Division
Design
JULY 2016C TxDOT:
250
TxDOT
POLLUTION CONTROL MEASURES
SEDIMENT AND WATER
TEMPORARY EROSION,
EROSION CONTROL LOG
ec916 CK:DW:KM LSLS/PT CK:TxDOT assumes no responsibility for the conversion of this standard to other formats or for incorrect results or damages resulting from its use.The use of this standard is governed by the "Texas Engineering Practice Act". No warranty of any kind is made by TxDOT for any purpose whatsoever. DISCLAIMER:FILE:DATE:$FILE$$DATE$
EROSION CONTROL LOG AT CURB INLET
CL-CI
EROSION CONTROL LOG AT CURB INLET
CL-CI
SANDBAG DETAIL
SECTION B-B
16"-18"
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT01.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT01.dgn1:404:44:05 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
12" WATER LINE A
WATER PLAN & PROFILE
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
PARKING AREA
S
S
S
587.72
5/8" IRS W/RANDOM
3
0LOT 24A
LOOP 288
7-ELEVEN INC
LOT 1
LOT 1
101 N LOOP 288
DENNIS J KOOP
LOT 1
3612 E McKINNEY STREET
McKINNEY BUILDING, LP
VOL. 1029, PG. 281
UTILITY EASEMENT
75' MAINTAINING PUBLIC
VOL. 60
3,
PG. 520
EASEMENT
16' PUBL
IC UT
IL
ITY
CAB. R, PG. 32
EASEMENT
20' PUBLIC UTILITY
CAB. F, PG. 336ELEC. EASEMENT20' UTILITY &
VOL. 603, PG. 520
EASEMENT16' PUBL
IC UT
IL
ITY
101 S LOOP 288
INVESTMENT COMPANY
SEJ ASSET MANAGEMENT &
CAB. F, PG. 336& ELEC.EASEMENT16' UTILITY
D.R.D.C.T.
PG. 394
VOL. 440,
EASEMENT
DRAINAGE
40' TXDOT
WV
WV WV
LT
LT
LT
LT
LT30" WW3
0
" WW3
0
" WW8" WW8" WW
8" W
8" W8" W8" W2
0" W
2
0" W
8" W
24" RCP
36" RCP
36" RCP
BOX CULVERTEx. 9'
x
5' BOX CULVERTEx.
9'
x
5' BOX CULVERTEx.
9'
x
5' BOX CULVERTEx. 5'x4' BOX CULVERTEx.
5'x4' BOX CULVERTEx.
5'
x
4' BOX CULVERTEx.
5'
x
3' BOX CULVERTEx.
6'
x
3'
24" RCP
24" RCP
24
" RC
P
WV
2
0" W
PT 90+20.1888+00 90+00
91+00
87+00
1
0072+
0
0
100
7
3
+0
0
1
0
0
7
4
+0
0
89+00
24" RCP
4'X2' RCB
12" W
12" W
91+00FL 12" = 582.07 FL 12" = 582.17 FL 12" = 582.00FL EX. 8" = 582.00Ex. 8" Water 1-12" 11.25° H. BENDINSTALL:LINE A 90+92.17, 43.17' RT1-12" GATE VALVE1-12"x6" TEEINSTALL:LINE A 91+00.00, 41.74' RT1-12" 11.25° H. BENDINSTALL:LINE A 91+33.07, 35.69' RT(+) 0.20%
AT PIPE CL
PROP. GROUND
AT PIPE CL
EX. GROUNDBEGIN 12" PVC WATER LINE A1-12" GATE VALVE1-12" 22.5° H. BEND1-12"x8" REDUCERINSTALL:CONNECT TO EX. 8" WATERLINE A 90+65.00, 53.93' RTEX. GAS EX. CCTV
CL McKINNEY STREET
McKINNEY STREET
MATCHLINE STA 91+50251MATCHLINE STA 91+50N LOOP 288S LOOP
2
8812" WATER LINE A
1-12" GATE VALVE
11 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-12"x6" TEE
INSTALL:
91+00.00, 41.74' RT
EX. 8" WATER
CUT & PLUG
EX. R.O.W
EX. R.O.W
EX. R.O.W
EX. R.O.W
570
600
595
585
580
575
590
570
600
595
585
580
575
590
EX. 8" WATER TO BE KILLED
12" PVC C900 (DR-14) WATER
INSTALL 88 LF
BEGIN PROP. 12" WATER LINE A
CONNECT TO EX. 8 WATER (W)
1-12" GATE VALVE
1-12" 22.5° H. BEND
1-12"x8" REDUCER
INSTALL:
90+65.00, 53.93' RT
1-12" 11.25° H. BEND
INSTALL:
90+92.17, 43.17' RT
1-12" 11.25° H. BEND
INSTALL:
91+33.07, 35.69' RT
570
600
595
585
580
575
590
CLASS B-3 EMBEDMENT
88 LF 12" PVC C900 (DR-14)
12" WATER LINE A
24" RCP
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT02.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT02.dgn1:404:44:08 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
12" WATER LINE A
WATER PLAN & PROFILE
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
V
E
PARKING AREA
S
PARKING AREA
LOT 1
3730 E McKINNEY STREET
LISA FONG LEUNG
LOT 1
100 N LOOP 288
100 NORTH LOOP 288, LLC
LOT 41
101 S LOOP 288
DNB INVESTMENTS LTD
LOT 1
101 S LOOP 288
SEJ ASSET MANAGEMENT & INVESTMENT COMPANY
LOT 24A
LOOP 288
7-ELEVEN INC
VOL. 603, PG. 520
EASEMENT
16' PUBLIC UTILITY
CAB. R, PG. 32
EASEMENT
20' PUBLIC UTILITY CAB. D, PG. 191
16' UTILITY EASEMENT
WV
WV
8" WW 8" WW 8" WW
8" W8" W 8" W
8" W
8" W
8" W 8" W 8" W
24" RCP
18" RCP
15" RCP
24" RCP 8" W
20" W
PT 94+85.56 PC 93+74.5992+00 93+00 94+00 95+00 96+00
D18" RCP 18" RCP 18" RCP 18"
24" RCP
D
4'X2' RCB RCP30" 24" RCP
18"
12" W 12" W 12" W
12" W
20" W
20" W
20" W
20"
W
SLEEVES6" PVC
SLEEVES6" PVC SLEEVES6" PVC 6" W6" W1-12" GATE VALVE1-12"x6" TEEINSTALL:LINE A 94+00.00, 39.91' RTAT PIPE CL
PROP. GROUND
AT PIPE CL
EX. GROUND2.69° LEFTPULL PIPELINE A 92+24.89, 40.00' RT1.82° RIGHTPULL PIPELINE A 94+30.08, 39.57' RT(+) 0.20%
EX. FIBER EX. CCTV 1.43° LEFTPULL PIPELINE A 95+60.00, 40.00' RT1-12" GATE VALVE1-12"x6" TEEINSTALL:LINE A 94+25.00, 39.64' RT1-12" GATE VALVE1-12"x6" TEEINSTALL:LINE A 96+00.00, 39.00' RT92+00 93+00 94+00 95+00 96+00FL 12" = 582.17 FL 12" = 582.27 FL 12" = 582.37 FL 12" = 582.47 FL 12" = 582.57 FL 12" = 582.77 FL 12" = 582.87 FL 12" = 582.97 FL 12" = 583.17 FL 6" = 582.92FL 12" = 582.67 FL 6" = 582.97FL 12" = 582.72 FL 6" = 582.32FL 12" = 583.07 CL McKINNEY STREET
McKINNEY STREET
MATCHLINE STA 96+50252MATCHLINE STA 91+50MATCHLINE STA 91+50MATCHLINE STA 96+5012" WATER LINE A
1-12" GATE VALVE
6 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-12"x6" TEE
INSTALL:
94+00.00, 39.91' RT
EX. R.O.W
EX. R.O.W
EX. FH
REMOVE & DELIVER
570
600
595
585
580
575
590
570
600
595
585
580
575
590
CLASS B-3 EMBEDMENT
499 LF 12" PVC C900 (DR-14)
12" WATER LINE A
SEE SHEET20" WATER LINE B 20" WATER LINE B
EX. 8" WATER TO BE KILLED
12" PVC C900 (DR-14) WATER
INSTALL 499 LF
257SEE SHEET
20" WATER LINE B
40'40'1.82° RIGHT
PULL PIPE
94+30.08, 39.57' RT
2.69° LEFT
PULL PIPE
92+24.89, 40.00' RT
1-12" GATE VALVE
68 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-12"x6" TEE
INSTALL:
94+25.00, 39.64' RT
101 S LOOP 288
DNB INVESTMENTS LTD
LOT 41
18" RCP
1-12" GATE VALVE
68 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-12"x6" TEE
INSTALL:
96+00.00, 39.00' RT
3730 E McKINNEY STREET
LISA FONG LEUNG
LOT 1
1.43° LEFT
PULL PIPE
95+60.00, 40.00' RT
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT03.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT03.dgn1:404:44:10 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
12" WATER LINE A
WATER PLAN & PROFILE
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
V
V
PARKING AREA
S
S S
590.91
5/8" IRS W/RANDOM
31
LOT 1
E McKINNEY STREET
CCD-RLG DENTON I LP
LOT 1
3701 E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
LOT 1
3730 E McKINNEY STREET
LISA FONG LEUNG 191 DUCHESS DRIVE
JBJ/CALDER FUND VII JOINT VENTURE
LOT 1
CAB. D, PG. 191
16' UTILITY EASEMENT
CAB. D, PG. 15
20' PUBLIC UTILITY EASEMENT
CAB. O, PG. 264
EASEMENT
15' PUBLIC UTILITY
CAB. O, PG. 264
10' UTILITY EASEMENT
CAB. O, PG. 264
10' UTILITY EASEMENT
CAB. XX, PG. XX
EASEMENT
PRIVATE DRAINAGE
CAB. X, PG. XX
EASEMENT
8' PUBLIC UTILITY
WV
WV
WV
8" WW
8" WW 8" WW
8" W 8" W 8" W 8" W
8" W
8" W 8" W 6" W(15" STEEL ENCASEMENT)8" WW(15" STEEL ENCASEMENT)8" WW8" WW8" W8
" W6" W
6" W6" W
6" W
T PC 99+35.0897+00 98+00 99+00 100+00 101+00
24" RCP
18" RCP
D18"
D
20" W
12" W 12" W 12" W 12" W
20" W 20" W
20" W
6" W6" WSLEEVES
6" PVC
SLEEVES6" PVC SLEEVES6" PVC 6" W1-12" GATE VALVE1-12"x6" TEEINSTALL:LINE A 97+00.00, 37.50' RT1-12" GATE VALVE1-12"x6" TEEINSTALL:LINE A 99+75.00, 37.50' RT1-12" GATE VALVE1-12"x6" TEEINSTALL:LINE A 100+25.00, 38.10' RTAT PIPE CL
EX. GROUND
AT PIPE CL
PROP. GROUND
1.43° RIGHTPULL PIPELINE A 96+60.00, 37.50' RT(+) 0.20%(-) 0.24%(-) 0.24%(-) 0.80%PULL PIPE (DOWN)LINE A 97+25.00, 37.50' RTPULL PIPE (DOWN)LINE A 99+50.00, 37.50' RTEX. GAS
FL 8" 579.81+/-
W/ 15" STEEL ENCASEMENT
EX. 8" WW 1-12" GATE VALVE1-12"x6" TEEINSTALL:LINE A 100+15.00, 38.01' RT97+00 98+00 99+00 100+00 101+00FL 12" = 583.17 FL 12" = 583.26FL 12" = 583.14FL 12" = 583.01FL 12" = 582.89FL 12" = 582.77 FL 12" = 581.97 FL 12" = 581.57 FL 12" = 581.17 FL 6" = 583.52FL 12" = 583.27 FL 6" = 582.82FL 12" = 582.57FL 6" = 582.42FL 12" = 582.17 FL 12" = 582.37 FL 12" = 583.32FL 6" = 582.50FL 12" = 582.25CL McKINNEY STREET
McKINNEY STREET
MATCHLINE STA 101+50MATCHLINE STA 96+50MATCHLINE STA 96+50MATCHLINE STA 101+50253DRIVEDUCHESS 12" WATER LINE A
EX. 6" WATER
CUT & PLUG
1-12" GATE VALVE
5 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-12"x6" TEE
INSTALL:
97+00.00, 37.50' RT
DEG = 1° 08' 45.30"
CURVE 1 (CV A-1)
CV A-1
= 3° 35' 00.00" LT
EX. R.O.W
EX. R.O.W
EX. R.O.W
1-12" GATE VALVE
63 LF 6" PVC WATER
1-6" 90° H. BEND
1-6" GATE VALVE
1-12"x6" TEE
INSTALL:
99+75.00, 37.50' RT
CONNECT TO EX. 6" WATER (E)
REMOVE EX. 6" 45°H. BEND
100+07.86, 66.68' RTEX. FH
REMOVE & DELIVER
570
600
595
585
580
575
590
570
600
595
585
580
575
590
N = 7127582.79
E = 2400948.27
T = 156.40'
L = 312.70'
R = 5,000.00'
1-12" GATE VALVE
66 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-12"x6" TEE
INSTALL:
100+25.00, 38.10' RT
CLASS B-3 EMBEDMENT
502 LF 12" PVC C900 (DR-14)
12" WATER LINE A
SEE SHEET20" WATER LINE B
EX. R.O.W
EX. R.O.W
PT STA = 102+94.35, 40.00' RT
PI STA = 101+38.99, 39.04' RT
PC STA = 99+34.77, 40.00' RT
PC CV A-1
99+34.77 LINE A
EX. 8" WATER TO BE KILLED
12" PVC C900 (DR-14) WATER
INSTALL 502 LF
258SEE SHEET
20" WATER LINE B
1.43° RIGHT
PULL PIPE
96+60.00, 37.50' RT
37.5'1-12" GATE VALVE
66 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-12"x6" TEE
INSTALL:
100+15.00, 38.01' RT
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT04.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT04.dgn1:404:44:12 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
12" WATER LINE A
WATER PLAN & PROFILE
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
DBL. 10" HACKBERRY
18" ELM 6" TREE
TRI 4" TREE
QUAD 6" ELM
DBL. 8" HACKBERRY 6" ELM DBL. 6"/12" HACKBERRY DBL. 6" HACKBERRY DBL. 8" HACKBERRY
4" ELM
6" ELM
DBL. 12" HACKBERRY
DBL. 6" ELM
10" TREE
S
586.24
X CUT SET
32
LOT 1
191 DUCHESS DRIVE
JBJ/CALDER FUND VII JOINT VENTURE
LOT 27
E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
LOT 29
E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
STREET
3910 E McKINNEY
SCOTTIE ADAMS
LOT 1
CAB. D, PG. 15
20' PUBLIC UTILITY EASEMENT
CAB. O, PG. 264
10' UTILITY EASEMENT
CAB. O, PG. 264
10' UTILITY EASEMENT
CAB. B, PG. 71
25' UTILITY EASEMENT
CAB. B, PG. 71
16' UTILITY EASEMENT
8" W
8" W 8" W
6" W
6" W6" W
6" W
8" WW
15" RCP PT 102+63.42 PC 104+55.99102+00 103+00 104+00 105+00
106+00
24" RCP18" RCP18" RCP18"
RCP36" RCP18"
12" W
20" W 20" W 20" W 20" W
12" W 12" W
12" W
SLEEVES6" PVC 6" W6" W102+00 103+00 104+00 105+00 106+00FL 12" = 581.17 FL 12" = 580.77 FL 12" = 579.97 FL 12" = 579.57 FL 12" = 579.17 FL 12" = 578.37 FL 12" = 577.97 FL 12" = 577.57 FL 6" = 579.02FL 12" = 578.77 FL 6" = 580.62FL 12" = 580.37 FL 6" = 578.14FL 12" = 577.89FL 6" = 578.42FL 12" = 578.17FL 6" = 580.42FL 12" = 580.17 1-12" GATE VALVE1-12"x6" TEEINSTALL:LINE A 102+50.00, 39.82' RT1-12" GATE VALVE1-12"x6" TEEINSTALL:LINE A 104+50.00, 40.00' RT1-12" GATE VALVE1-12"x6" TEEINSTALL:LINE A 105+60.00, 40.01' RT(-) 0.80%
AT PIPE CL
PROP. GROUND
AT PIPE CL
EX. GROUND
EX. GAS
EX. CCTV EX. CCTV
EX. FIBER1-12" GATE VALVE1-12"x6" TEEINSTALL:LINE A 102+75.00, 39.96' RT1-12" GATE VALVE1-12"x6" TEEINSTALL:LINE A 105+25.00, 40.01' RTMcKINNEY STREET
MATCHLINE STA 106+00MATCHLINE STA 101+50MATCHLINE STA 101+50254MATCHLINE STA 106+00CL McKINNEY STREET
CONNECT TO EX. 8 WATER (NE)1-12" GATE VALVE1-12"x8" TEEINSTALL:90+56.50, 44.00' RT
6" W
1-12" GATE VALVE
5 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-12"x6" TEE
INSTALL:
104+50.00, 40.00' RT
1-12" GATE VALVE
6 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-12"x6" TEE
INSTALL:
102+50.00, 39.82' RT
CV A-1
DEG = 3° 25' 14.32"
CURVE 2 (CV A-2)
CV A-2
EX. R.O.W
EX. R.O.W
CONNECT TO EX. 6" WATER (SW)
1-12" GATE VALVE
5 LF 6" PVC WATER
1-6" 45° H. BEND
1-6" GATE VALVE
1-12"x6" TEE
INSTALL:
105+60.00, 40.01' RT
570
600
595
585
580
575
590
570
600
595
585
580
575
590
N = 7127378.85
E = 2401387.66
T = 166.20'
L = 331.32'
R = 1,675.00'
PC STA = 104+56.15, 40.00' RT
CLASS B-3 EMBEDMENT
455 LF 12" PVC C900 (DR-14)
12" WATER LINE A
SEE SHEET
PI STA = 106+18.40, 40.01' RT
PC STA = 107+79.57, 40.00' RT
PT CV A-1
102+94.35 LINE A
PC CV A-2
104+56.15 LINE A
EX. 8" WATER TO BE KILLED
12" PVC C900 (DR-14) WATER
INSTALL 455 LF
259
20" WATER LINE B
EX. 6" WATER
CUT & PLUG
40' = 11° 20' 00.00" LT
DEG = 1° 08' 45.30"
CURVE 1 (CV A-1)
= 3° 35' 00.00" LT
N = 7127582.79
E = 2400948.27
T = 156.40'
L = 312.70'
R = 5,000.00'
PT STA = 102+94.35, 40.00' RT
PI STA = 101+38.99, 39.04' RT
PC STA = 99+34.77, 40.00' RT
CRITERIA
WASTEWATER DESIGN
CITY OF DENTON
SAND ACCORDING TO
CEMENT-STABILIZED
WASTEWATER MANHOLE IN
ENCASE EXISTING
PLACE FINAL BACKFILL.
(MINIMUM 2.5 BAGS OF CEMENT PER CY OF SAND)
PLACE 2 FT OF CEMENT-STABILIZED SAND
TO THE SPRINGLINE OF EX. 8" WW PIPE.
REMOVE EXISTING EMBEDMENT
DONE BY OTHERS TO STA 119+50
CONTRACT, BEGIN WORK TO BE
STA 106+00 END WORK THIS
LINE A
12" WATER
1-12" GATE VALVE
69 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-12"x6" TEE
INSTALL:
102+75.00, 39.96' RT
LOT 1
191 DUCHESS DRIVE
JBJ/CALDER FUND VII JOINT VENTURE
1-12" GATE VALVE
69 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-12"x6" TEE
INSTALL:
105+25.00, 40.01' RT
6
" W
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT05.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT05.dgn1:404:44:15 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
12" WATER LINE A
WATER PLAN & PROFILE
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
V
PARKING AREA PARKING AREA
PARKING AREA
CONCRETE
PARKING AREA
PARKING AREA
PARKING AREA
24" HACKBERRYDBL. 12" TREE24" TREETRI 6" TREE
15" HACKBERRY10" CEDAR
DBL. 10" TREE
DBL. 12" HACKBERRY
S
LOT 38
LOT 4LOT 3LOT 2
3912 E McKINNEY STREET
DUNCAN STREET COMMERCIAL LLC
LOT 1
3910 E McKINNEY STREET
SCOTTIE ADAMS
LOT 29
E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
3801 E McKINNEY STREET
ANGEL & GRISELDA ENRIQUEZ
3919/3921 E McKINNEY STREET
NSA PROPERTY HOLDINGS, LLC
LOT 1R
3916 E McKINNEY STREET
EDWARD D & SHARYL K DIELEMAN
3918-3920 E McKINNEY STREET
LESLIE A & MICHAEL L ORINGDERFF
CAB. B, PG. 71
25' UTILITY EASEMENTCAB. B, PG. 71
16' UTILITY EASEMENT
CAB. Y, PG. 289
20' UTILITY EASEMENT
McKINNEY STREET
3919/3921 E
HOLDINGS, LLC
NSA PROPERTY
WV
WVWV
WV6" W
6" W
8" WW
8" WW 8" WW
8" W 8" W 8" W
6" W6" W
6" W
8" WW 8" WW
15" RCP
24" RCP
18" RCP
15" RCP
18" RCP 18" RCP
18" RCP
8" WW PT 107+79.73106+00
107+00 108+00 109+00 110+00
36" RCP 24"18"36" RCP
D 18"30" RCP24" RCP18"18"
R
C
P18"RCB
4'X4'
RCB
4'X4'
RCB
4'X4'
20" W
12" W
12" W 12" W 12" W
20" W 20" W 20" W
12" W12" WSLEEVES
6" PVC
SLEEVES
6" PVC
SLEEVES
6" PVC
SLEEVES
6" PVC
SLEEVES
6" PVC
SLEEVES6" PVC
SLEEVES6" PVC
106+00 107+00 108+00 109+00 110+00FL 12" = 577.57 FL 12" = 577.17 FL 12" = 576.83 FL 12" = 576.53 FL 12" = 575.93 FL 12" = 575.33 FL 12" = 575.03 FL 12" = 574.86 FL 12" = 577.01FL 6" = 577.17FL 12" = 576.92FL 12" = 576.23 FL 12" = 576.23 FL 6" = 575.88FL 12" = 575.63 FL 12" = 574.881-12" GATE VALVE1-12"x6" TEEINSTALL:LINE A 106+85.00, 40.01' RT1-12" GATE VALVE1-12"x6" TEEINSTALL:LINE A 109+60.00, 40.00' RTAT PIPE CL
PROP. GROUND 1-12" GATE VALVE1-12"x12" TEEINSTALL:LINE A 108+00.00, 40.00' RTPULL PIPE (UP)LINE A 106+70.00, 40.01' RT(-) 0.80%(-) 0.60%
(-) 0.60%
AT PIPE CL
EX. GROUND PULL PIPE (UP)LINE A 111+25.00, 40.00' RT(-) 0.10%
EX. CCTV
EX. GAS
EX. CCTV
FL 6" 577.85+/-
(TO BE KILLED)
EX. 6" WATER
FL 6" 577.47+/-
(TO BE KILLED)
EX. 6" WATER
CL McKINNEY STREET
McKINNEY STREET
MATCHLINE STA 110+50MATCHLINE STA 106+00255MATCHLINE STA 106+00MATCHLINE STA 110+501-12" GATE VALVE
8 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" 90° H. VALVE
1-6" GATE VALVE
1-12"x6" TEE
INSTALL:
106+85.00, 40.01' RT
1-12" GATE VALVE
6 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-12"x6" TEE
INSTALL:
109+00.00, 40.00' RT
CV A-2
EX. R.O.W
EX. R.O.W
EX. FH
REMOVE & DELIVER
570
595
585
580
575
590
570
595
585
580
575
590
565565
CLASS B-3 EMBEDMENT
455 LF 12" PVC C900 (DR-14)
12" WATER LINE A
PT CV A-2
107+79.57 LINE A
12" WATER LINE A
EX. 8" WATER TO BE KILLED
12" PVC C900 (DR-14) WATER
INSTALL 455 LF
15 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-12"x6" TEE
INSTALL:
108+00.00, 28.25' LT
CONNECT TO PROP. 20"x12" TEE(N)
87 LF 12" PVC WATER
2-12" GATE VALVES
1-12"x12" TEE
INSTALL:
108+00.00, 40.00' RT
260SEE SHEET
20" WATER LINE B
40'40'DEG = 3° 25' 14.32"
CURVE 2 (CV A-2)
N = 7127378.85
E = 2401387.66
T = 166.20'
L = 331.32'
R = 1,675.00'
PC STA = 104+56.15, 40.00' RT
PI STA = 106+18.40, 40.01' RT
PC STA = 107+79.57, 40.00' RT
= 11° 20' 00.00" LTPULL PIPE (UP)
106+70.00, 40.01' RT
PLACE FINAL BACKFILL.
CEMENT PER CY OF SAND)
(MINIMUM 2.5 BAGS OF
CEMENT-STABILIZED SAND
PLACE 2 FT OF
OF EX. 8" WW PIPE.
TO THE SPRINGLINE
REMOVE EXISTING EMBEDMENT
REFERENCE ONLY
BY OTHERS TO STA 119+50
BEGIN WORK TO BE DONE
END WORK THIS CONTRACT,
STA 106+00
WASTEWATER DESIGN CRITERIAPER CITY OF DENTON(MINIMUM 18")1/2" STEEL ENCASEMENT PIPE LIMITS 100 LF
WATER DESIGN CRITERIA
PER CITY OF DENTON
(MINIMUM 18")
1/2" STEEL ENCASEMENT PIPE LIMITS
64 LF
36" RCP
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT06.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT06.dgn1:404:44:18 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
12" WATER LINE A
WATER PLAN & PROFILE
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
CONCRETE
CONCRETE
E
E
PARKING AREA
S
S
S
D
S
585.34
PK NAIL SET
33
S
LOT 153
LOT 3
LOT 151 (PT)
E McKINNEY STREET (200' STRIP)
BCI REAL ESTATE VENTURES, LP
LOT 5R1
LOT 152
STREET
4001 E McKINNEY
CITY OF DENTON
E McKINNEY STREET
CITY OF DENTON
3922 E McKINNEY STREET
GOEL VENTURES ONE, LLC
3918-3920 E McKINNEY STREET
LESLIE A & MICHAEL L ORINGDERFF
3923 E McKINNEY STREET
DENTON 3919 McKINNEY, LLC
CAB. B, PG. 71
25' UTILITY EASEMENT
CAB. Y, PG. 289
20' UTILITY EASEMENT
CAB. B, PG. 147
16' UTILITY EASEMENT
VOL. 5039, PG. 01970
DRAINAGE EASEMENT
20' PERMANENT
McKINNEY STREET
3919/3921 E
HOLDINGS, LLC
NSA PROPERTY
LOT 1R
8" WW
8" W
6" W
12" W
12" W12" W6" W 12" W 12" W 20" W16" W
20" W20" W20" W
20" W
8" WW 10"
WW8" WW8" WW10" WW8" W12"
W20" W 12" W
12" W8" W
8" W
8" WW 8" WW8" WW
2-18" RCP
27" RCP
BOX CULVERT6'x4'BOX CULVERT6'
x
4'BOX CULVERT6'x4'18"
RCPB
O
X
C
U
L
V
E
R
T
6'x4'
8" WW
(ABANDONED)10"
WW(AB
AND
ONE
D)
1
0" WW8" WW
10'x4' RCBC PT 112+56.89 PC 111+52.17112+00 113+00 114+00 115+00
222+00223+00224+00BOX CULVERT5'x4'18" RCP18"18" RCPD18"BOX CULVERT6'x4'BOX CULVERT6'x4'RCP24" RCP24" D
4'X4' RCBRCB
4'X4'20" W12" W
12" W16" W 16" W10" WW20" W
SLEEVES6" PVC SLEEVES6" PVC
SLEEVES6" PVC SLEEVES6" PVC 6" W111+00 112+00 FL EX. 6" = 567.50FL 12" = 567.50 FL 12" = 574.86 FL 12" = 574.81FL 12" = 574.76FL 12" = 567.52FL 6" = 575.05FL 12" = 574.80FL 12" = 574.74FL 12" = 567.70FL 6" = 575.02FL 12" = 574.77Ex. 12" Water1-12" GATE VALVE1-12"x6" TEEINSTALL:LINE A 111+10.00, 40.00' RTEND 12" PVC WATER LINE ACONNECT TO EX. 12" WATERREMOVE EX. 12" 45° H. BENDLINE A 112+02.09, 50.91' RTAT PIPE CL
PROP. GROUND 1-12" 45° COMBO. BENDINSTALL:LINE A 111+84.98, 39.94' RT1-12" 22.5° V. BENDINSTALL:LINE A 111+68.00, 40.00' RTAT PIPE CL
EX. GROUND
(-) 1.20%
(-) 41.42
%(-) 0.10%
EX. CCTV EX. GAS1-12" GATE VALVE1-12"x6" TEEINSTALL:LINE A 111+35.00, 40.00' RTCL McKINNEY STREET
McKINNEY STREET
MATCHLINE STA 110+50256MATCHLINE STA 110+50N MAYHI
LL ROADS MAYHI
LL ROAD
F.L. XXXT.C. XXXCL 10' REC. INLETPAV STA 111+71.62, 50.50' RT
F.L. XXXT.C. XXXCL 10' REC. INLETPAV STA 113+99.92, 39.49' RT
12" WATER LINE A
12" PVC C900 (DR-14) WATER
INSTALL 155 LF
EX. 12" WATER
CUT & PLUG
1-12" GATE VALVE
5 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-12"x6" TEE
INSTALL:
111+10.00, 40.00' RT
EX. R.O.W
EX. R.O.W
EX. R.O.W
EX. R.O.W
END 12" PVC WATER LINE A
CONNECT TO EX. 12" WATER (SE)
REMOVE EX. 12" 45° H. BEND
112+02.09, 50.91' RT
1-12" 22.5° V. BEND
INSTALL:
111+68.00, 40.00' RT
570
595
585
580
575
590
565
560
570
595
585
580
575
590
565
560
CLASS B-3 EMBEDMENT
155 LF 12" PVC C900 (DR-14)
12" WATER LINE A
1-12" 45° COMBO. BEND
INSTALL:
111+84.98, 39.94' RT
EX. 8" WATER TO BE KILLED12" PVC C900 (DR-14) WATERINSTALL 500 LF
EX. 8" WATER TO BE KILLED
261SEE SHEET
20" WATER LINE B
261SEE SHEET
16" WATER LINE C40'REFERENCE ONLY
1-12" GATE VALVE
69 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-12"x6" TEE
INSTALL:
111+45.00, 40.00' RT
48" RCP
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT07.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT07.dgn1:404:44:20 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
20" WATER LINE B
WATER PLAN & PROFILE
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
V
PARKING AREA
E
PARKING AREA
S
PARKING AREA
LOT 1
3730 E McKINNEY STREET
LISA FONG LEUNG
LOT 1
100 N LOOP 288
100 NORTH LOOP 288, LLC
LOT 41
101 S LOOP 288
DNB INVESTMENTS LTD
LOT 1
101 S LOOP 288
SEJ ASSET MANAGEMENT & INVESTMENT COMPANY
LOT 24A
LOOP 288
7-ELEVEN INC
CAB. R, PG. 32
EASEMENT
20' PUBLIC UTILITY
VOL. 603, PG. 520
EASEMENT
16' PUBLIC UTILITY
CAB. R, PG. 32
EASEMENT
20' PUBLIC UTILITY CAB. D, PG. 191
16' UTILITY EASEMENT
VOL. 603, PG. 520
EASEMENT
16' PUBLIC UTILITY
101 S LOOP 288INVESTMENT COMPANYSEJ ASSET MANAGEMENT &
WV
WV
8" WW 8" WW 8" WW
8" W8" W 8" W
8" W
8" W
8" W 8" W 8" W
24" RCP
18" RCP
15" RCP
24" RCP
WV
8" W
20" W
PT 94+85.56 PC 93+74.5992+00 93+00 94+00 95+00 96+00
D18" RCP 18" RCP 18" RCP 18"
24" RCP
D
4'X2' RCB RCP30" 24" RCP
18"
12" W 12" W 12" W
12" W
20" W
20" W
20" W
20"
W
SLEEVES6" PVC
SLEEVES6" PVC SLEEVES6" PVC 6" W6" W92+00 93+00 94+00 95+00 96+00FL 20" = 580.50FL EX. 20" = 580.50FL 20" = 580.00 FL 20" = 579.75 FL 20" = 579.50 FL 20" = 579.45 FL 20" = 579.40 FL 20" = 579.35 FL 20" = 579.30 FL 20" = 579.25 FL 20" = 579.20 FL 20" = 580.25 Ex. 20" Water
AT PIPE CL
PROP. GROUND
BEGIN 20" D.I. WATER LINE B1-20" GATE VALVE1-20" 45° H. BENDINSTALL:CONNECT TO EX. 20" WATERLINE B 91+50.00, 80.39' LT1-20" 45° H. BENDINSTALL:LINE B 91+60.85, 66.15' LT4.00° RIGHTPULL PIPELINE B 92+50.09, 55.61' LTAT PIPE CL
EX. GROUNDPULL PIPE (UP)LINE B 93+50.00, 39.56' LT(-) 0.50%(-) 0.10%(-) 0.50%
ELECTRIC
EX. UNDERGROUND
ELECTRIC
EX. UNDERGROUND
FL 30" 584.86
PROP. 30" RCP1-20" GATE VALVE1-20" 11.25° H. BENDINSTALL:LINE B 93+31.65, 40.14' LT(To Be Killed)
0' - 15' Rt.
Ex. 8" Water
FL 8" 583.47+/-
(TO BE KILLED)
EX. 8" WATER
(To Be Killed)
3' Lt.
Ex. 8" Water
CL McKINNEY STREET
McKINNEY STREET
257MATCHLINE STA 96+5020" WATER LINE B
EX. R.O.W
EX. R.O.W
570
585
580
575
590
600
595
570
585
580
575
590
600
595
MATCHLINE STA 96+5012" PVC C900 (DR-14) WATERINSTALL 500 LF
252SEE SHEET
12" WATER LINE A 37'4.00° RIGHT
PULL PIPE
92+50.09, 55.61' LT
1-20" 45° H. BEND
INSTALL:
91+60.85, 66.15' LT
BEGIN 20" D.I. WATER LINE B
1-20" GATE VALVE
1-20" 45° H. BEND
INSTALL:
CONNECT TO EX. 20 WATER (NW)
CUT & PLUG EX. 20" WATER (SE)
91+50.00, 80.39' LT
EX. FH
REMOVE & DELIVER
CLASS B-3 EMBEDMENT
510 LF 20" DUCTILE IRON AWWA CLASS 52
20" WATER LINE B
EX. 8" WATER TO BE KILLED
20" DUCTILE IRON CLASS 52 WATER
INSTALL 510 LF
1-20" GATE VALVE
1-20" 11.25°H. BEND
INSTALL:
93+31.65, 40.14' LT
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT08.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT08.dgn1:404:44:22 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
20" WATER LINE B
WATER PLAN & PROFILE
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
V
V
PARKING AREA
S
S S
590.91
5/8" IRS W/RANDOM
31
LOT 1
E McKINNEY STREET
CCD-RLG DENTON I LP
LOT 1
3701 E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
LOT 1
3730 E McKINNEY STREET
LISA FONG LEUNG 191 DUCHESS DRIVE
JBJ/CALDER FUND VII JOINT VENTURE
LOT 1
CAB. D, PG. 191
16' UTILITY EASEMENT
CAB. D, PG. 15
20' PUBLIC UTILITY EASEMENT
CAB. O, PG. 264
EASEMENT
15' PUBLIC UTILITY
CAB. O, PG. 264
10' UTILITY EASEMENT
CAB. O, PG. 264
10' UTILITY EASEMENT
CAB. XX, PG. XX
EASEMENT
PRIVATE DRAINAGE
CAB. X, PG. XX
EASEMENT
8' PUBLIC UTILITY
WV
WV
WV
8" WW
8" WW 8" WW
8" W 8" W 8" W 8" W
8" W
8" W 8" W 6" W(15" STEEL ENCASEMENT)8" WW(15" STEEL ENCASEMENT)8" WW8" WW8" W8
" W6" W
6" W6" W
6" W
T PC 99+35.0897+00 98+00 99+00 100+00 101+00
24" RCP
18" RCP
D18"
D
20" W
12" W 12" W 12" W 12" W
20" W 20" W
20" W
6" W6" WSLEEVES
6" PVC
SLEEVES6" PVC SLEEVES6" PVC 6" W97+00 98+00 99+00 100+00 101+00FL 20" = 579.20 FL 20" = 579.15 FL 20" = 579.10 FL 20" = 579.05 FL 20" = 579.00 FL 20" = 578.95 FL 20" = 578.90 FL 20" = 578.85 FL 20" = 578.45 FL 20" = 578.05 FL 20" = 577.65 AT PIPE CL
PROP. GROUND
AT PIPE CL
EX. GROUND
(-) 0.10%(-) 0.80%PULL PIPE (DOWN)LINE B 100+00.00, 37.00' LTEX. FIBER EX. GAS
FL 24" 584.94
PROP. 24" RCP
FL 8" 583.47+/-
W/ 15" STEEL ENCASEMENT
EX. 8" WW
(To Be Killed)
4' - 9' Lt.
Ex. 8" Water
CL McKINNEY STREET
McKINNEY STREET
MATCHLINE STA 101+50MATCHLINE STA 96+50MATCHLINE STA 96+50MATCHLINE STA 101+50258DRIVEDUCHESS 20" WATER LINE B
DEG = 1° 06' 06.63"
CURVE 1 (CV B-1)
= 3° 35' 00.00" LT
CV B-1
EX. R.O.W
EX. R.O.W
EX. R.O.W
570
585
580
575
590
600
595
570
585
580
575
590
600
595
N = 7127668.46
E = 2400946.99
T = 162.66'
L = 325.21'
R = 5,200.00'
20" DUCTILE IRON C151 WATERINSTALL 488 LF
PC CV B-1
99+35.49 LINE B
PI STA = 100+99.31, 36.99' LT
PC STA = 102+63.02, 37.00' LT
PC STA = 99+35.49, 37.00' LT
EX. R.O.W
EX. R.O.W
SEE SHEET 253
12" WATER LINE A37'E McKINNEY STREET
CCD-RLG DENTON I LP
LOT 1
CONNECT TO EX. 8" WATER (NE)
15 LF 8" PVC WATER
2-8" GATE VALVES
1-20" GATE VALVE
1-20"x8" TEE
INSTALL:
REMOVE EX. 8" GATE VALVE
REMOVE EX. 8"x8' TEE
98+47.50, 37.00' LT
7 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-8"x6" TEE
INSTALL:
98+47.50, 47.00' LT
CONNECT TO EX. 8" WATER (NE)
11 LF 8" PVC WATER
1-8" GATE VALVE
1-20" GATE VALVE
1-20"x8" TEE
INSTALL:
REMOVE EX. 8"x8' TEE (N)
99+59.60, 37.00' LT
CLASS B-3 EMBEDMENT
510 LF 20" DUCTILE IRON AWWA CLASS 52
20" WATER LINE B
EX. 8" WATER TO BE KILLED
20" DUCTILE IRON CLASS 52 WATER
INSTALL 498 LF
CLASS B-3 EMBEDMENT
498 LF 20" DUCTILE IRON AWWA CLASS 52
20" WATER LINE B
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT09.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT09.dgn1:404:44:25 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
20" WATER LINE B
WATER PLAN & PROFILE
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
E
DBL. 10" HACKBERRY
18" ELM 6" TREE
TRI 4" TREE
QUAD 6" ELM
DBL. 8" HACKBERRY 6" ELM DBL. 6"/12" HACKBERRY DBL. 6" HACKBERRY DBL. 8" HACKBERRY
4" ELM
6" ELM
DBL. 12" HACKBERRY
DBL. 6" ELM
10" TREE
S
586.24
X CUT SET
32
LOT 1
191 DUCHESS DRIVE
JBJ/CALDER FUND VII JOINT VENTURE
LOT 27
E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
LOT 29
E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
STREET
3910 E McKINNEY
SCOTTIE ADAMS
LOT 1
CAB. D, PG. 15
20' PUBLIC UTILITY EASEMENT
CAB. O, PG. 264
10' UTILITY EASEMENT
CAB. O, PG. 264
10' UTILITY EASEMENT
CAB. B, PG. 71
25' UTILITY EASEMENT
CAB. B, PG. 71
16' UTILITY EASEMENT
8" W
8" W 8" W
6" W
6" W
6" W6" W
6
" W6" W
8" WW
15" RCP PT 102+63.42 PC 104+55.99102+00 103+00 104+00 105+00
106+00
24" RCP18" RCP18" RCPD18"
RCP36" RCP18"
12" W
20" W 20" W 20" W 20" W
12" W 12" W
12" W
SLEEVES6" PVC 6" W6" W102+00 103+00 104+00 105+00 106+00FL 20" = 577.65 FL 20" = 577.25 FL 20" = 576.85 FL 20" = 576.45 FL 20" = 576.05 FL 20" = 575.65 FL 20" = 575.25 FL 20" = 574.85 FL 20" = 574.45 FL 20" = 574.05 AT PIPE CL
PROP. GROUND
AT PIPE CL
EX. GROUND FL 36" 579.42PROP. 36" RCP(-) 0.80%FL 36" 579.42
PROP. 36" RCP
(To Be Killed)
0' - 9' Lt.
Ex. 8" Water
(To Be Killed)
4' Rt.
Ex. 8" Water
FL 8" 585.76+/-
(TO BE KILLED)
EX. 8" WATER
McKINNEY STREET
MATCHLINE STA 106+00MATCHLINE STA 101+50MATCHLINE STA 101+50259MATCHLINE STA 106+00CL McKINNEY STREET
20" WATER LINE B
CONNECT TO EX. 8 WATER (NE)1-12" GATE VALVE1-12"x8" TEEINSTALL:90+56.50, 44.00' RT
CV B-2
CV B-1
EX. R.O.W
EX. R.O.W
585
580
575
590
600
595
570
585
580
575
590
600
595
570
PT CV B-1
102+63.02 LINE B
PC CV B-2
104+55.96 LINE B
254SEE SHEET
12" WATER LINE A37'
DEG = 1° 06' 06.63"
CURVE 1 (CV B-1)
= 3° 35' 00.00" LT
N = 7127668.46
E = 2400946.99
T = 162.66'
L = 325.21'
R = 5,200.00'
PI STA = 100+99.31, 36.99' LT
PC STA = 102+63.02, 37.00' LT
PC STA = 99+35.49, 37.00' LT
DEG = 3° 24' 51.55"
CURVE 2 (CV B-2)
N = 7127451.91
E = 2401413.14
= 11° 20' 00.00" LT
T = 158.76'
L = 346.49'
R = 1,600.00'
PC STA = 104+55.96, 37.00' LT
PI STA = 106+18.39, 37.00' LT
PT STA = 107+79.77, 37.00' LT
DONE BY OTHERS TO STA 119+50
CONTRACT, BEGIN WORK TO BE
STA 106+00 END WORK THIS
EX. 8" WATER TO BE KILLED
20" DUCTILE IRON CLASS 52 WATER
INSTALL 446 LF
CLASS B-3 EMBEDMENT
446 LF 20" DUCTILE IRON AWWA CLASS 52
20" WATER LINE B
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT10.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT10.dgn1:404:44:27 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
20" WATER LINE B
WATER PLAN & PROFILE
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
V
PARKING AREA PARKING AREA
PARKING AREA
CONCRETE
PARKING AREA
PARKING AREA
PARKING AREA
24" HACKBERRYDBL. 12" TREE24" TREETRI 6" TREE
15" HACKBERRY10" CEDAR
DBL. 10" TREE
DBL. 12" HACKBERRY
S
LOT 38
LOT 4LOT 3LOT 2
3912 E McKINNEY STREET
DUNCAN STREET COMMERCIAL LLC
LOT 1
3910 E McKINNEY STREET
SCOTTIE ADAMS
LOT 29
E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
3801 E McKINNEY STREET
ANGEL & GRISELDA ENRIQUEZ
3919/3921 E McKINNEY STREET
NSA PROPERTY HOLDINGS, LLC
LOT 1R
3916 E McKINNEY STREET
EDWARD D & SHARYL K DIELEMAN
3918-3920 E McKINNEY STREET
LESLIE A & MICHAEL L ORINGDERFF
CAB. B, PG. 71
25' UTILITY EASEMENTCAB. B, PG. 71
16' UTILITY EASEMENT
CAB. Y, PG. 289
20' UTILITY EASEMENT
McKINNEY STREET
3919/3921 E
HOLDINGS, LLC
NSA PROPERTY
WV
WVWV
WV6" W
6" W
8" WW
8" WW 8" WW
8" W 8" W 8" W
6" W6" W
6" W
8" WW 8" WW
15" RCP
24" RCP
18" RCP
15" RCP
18" RCP 18" RCP
18" RCP
8" WW PT 107+79.73106+00
107+00 108+00 109+00 110+00
36" RCP 24"18"36" RCP
D 18"30" RCP24" RCP18"18"
R
C
P18"RCB
4'X4'
RCB
4'X4'
RCB
4'X4'
20" W
12" W
12" W 12" W 12" W
20" W 20" W 20" W
12" W12" WSLEEVES
6" PVC
SLEEVES
6" PVC
SLEEVES
6" PVC
SLEEVES
6" PVC
SLEEVES
6" PVC
SLEEVES6" PVC
SLEEVES6" PVC
106+00 107+00 108+00 109+00 110+00FL 20" = 573.65FL 12" = 573.08FL 20" = 572.75 FL 20" = 574.05 FL 20" = 573.35 FL 20" = 573.05 FL 20" = 572.80 FL 20" = 572.85 FL 20" = 572.90 FL 20" = 572.95 FL 20" = 573.00 AT PIPE CL
PROP. GROUND
1-20" GATE VALVE1-20"x12" TEEINSTALL:LINE B 108+00.00, 37.00' LTAT PIPE CL
EX. GROUNDPULL PIPE (UP)LINE B 106+50.00, 37.00' LT(-) 0.80%(-) 0.60%
EX. GASFL 30" 578.16
PROP. 30" RCP
FL 24" 578.14
PROP. 24" RCP
FL 6" 577.75
(TO BE KILLED)
EX. 6" WATER
FL 18" 579.00
PROP. 18" RCP
FL 24" 577.95
PROP. 24" RCP
(-) 0.60%(+) 0.10%
FL 8" 579.16+/-
(TO BE KILLED)
EX. 8" WATER (To Be Killed)
6' Lt.
Ex. 8" Water
CL McKINNEY STREET
McKINNEY STREET
MATCHLINE STA 110+50MATCHLINE STA 106+00260MATCHLINE STA 106+00MATCHLINE STA 110+5020" WATER LINE B
CV B-2
EX. R.O.W
EX. R.O.W
570
585
580
575
590
565
595
585
580
575
590
565
595
570
PT CV B-2
107+79.77 LINE B
CONNECT TO PROP. 12" PVC WATER
1-20" GATE VALVE
1-20"x12" TEE
INSTALL:
108+00.00, 37.00' LT
255SEE SHEET
12" WATER LINE A 37'DEG = 3° 24' 51.55"
CURVE 2 (CV B-2)
N = 7127451.91
E = 2401413.14
= 11° 20' 00.00" LT
T = 158.76'
L = 346.49'
R = 1,600.00'
PC STA = 104+55.96, 37.00' LT
PI STA = 106+18.39, 37.00' LT
PT STA = 107+79.77, 37.00' LT
119+50
TO STA
BY OTHERS
TO BE DONE
BEGIN WORK
CONTRACT,
THIS
END WORK
STA 106+00
REFERENCE ONLY
WATER DESIGN CRITERIA
PER CITY OF DENTON
(MINIMUM 18")
1/2" STEEL ENCASEMENT PIPE LIMITS
64 LF
EX. 8" WATER TO BE KILLED
20" DUCTILE IRON CLASS 52 WATER
INSTALL 446 LF
CLASS B-3 EMBEDMENT
446 LF 20" DUCTILE IRON AWWA CLASS 52
20" WATER LINE B
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT11.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT11.dgn1:404:44:30 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
20" LINE B & 16" LINE C
WATER PLAN & PROFILE
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
CONCRETE
CONCRETE
E
E
PARKING AREA
S
S
S
D
S
585.34
PK NAIL SET
33
S
LOT 153
LOT 3
LOT 151 (PT)
E McKINNEY STREET (200' STRIP)
BCI REAL ESTATE VENTURES, LP
LOT 5R1
LOT 152
STREET
4001 E McKINNEY
CITY OF DENTON
E McKINNEY STREET
CITY OF DENTON
3922 E McKINNEY STREET
GOEL VENTURES ONE, LLC
3918-3920 E McKINNEY STREET
LESLIE A & MICHAEL L ORINGDERFF
3923 E McKINNEY STREET
DENTON 3919 McKINNEY, LLC
CAB. B, PG. 71
25' UTILITY EASEMENT
CAB. Y, PG. 289
20' UTILITY EASEMENT
CAB. B, PG. 147
16' UTILITY EASEMENT
VOL. 5039, PG. 01970
DRAINAGE EASEMENT
20' PERMANENT
McKINNEY STREET
3919/3921 E
HOLDINGS, LLC
NSA PROPERTY
8" WW
8" W
6" W
12" W
12" W12" W6" W 12" W 12" W 20" W16" W
20" W20" W20" W
20" W
8" WW 10"
WW8" WW8" WW10" WW8" W12"
W20" W 12" W
12" W8" W
8" W
8" WW 8" WW8" WW
2-18" RCP
27" RCP
BOX CULVERT6'x4'BOX CULVERT6'
x
4'BOX CULVERT6'x4'18"
RCPB
O
X
C
U
L
V
E
R
T
6'x4'
8" WW
(ABANDONED)10"
WW(AB
AND
ONE
D)
1
0" WW8" WW
10'x4' RCBC PT 112+56.89 PC 111+52.17111+00 112+00 113+00 114+00 115+00
222+00223+00224+00BOX CULVERT5'x4'18" RCP18"18" RCPD18"BOX CULVERT6'x4'BOX CULVERT6'x4'RCP24" RCP24" D
4'X4' RCBRCB
4'X4'20" W12" W
12" W16" W 16" W10" WW20" W
SLEEVES6" PVC SLEEVES6" PVC
SLEEVES6" PVC SLEEVES6" PVC 6" W111+00 FL 20" = 573.15FL EX. 20"=575.07FL 20" = 575.07FL 20" = 573.00 FL 20" = 573.05 FL 20" = 573.10 FL 20" = 573.15 FL 20" = 574.99Ex. 20" Water1-20" 45°H. BENDINSTALL:LINE B 111+63.32, 37.01' LTAT PIPE CL
PROP. GROUND
AT PIPE CL
EX. GROUND 1-20" 45°COMBO. BENDINSTALL:LINE B 111+92.31, 75.96' LT* DENOTES GRADE MEASURED ALONG ACTUAL LENGTH OF PIPE
38.62 LF
(+) 0.10%*
EX. GAS
EX. GAS
FL 24" 578.99
PROP. 24" RCP
FL 8" 576.15+/-
(ABANDONED)
EX. 8" WW 1-20" 45°COMBO. BENDINSTALL:LINE B 111+84.31, 76.94' LT14.67 LF
(+) 19.89%*(+) 0.50%*
9.26
(+) 0.10%END 20" D.I. WATER LINE BCONNECT TO EX. 20 WATER1-20" GATE VALVE1-20" 90° H. BENDINSTALL:REMOVE EX. 20"x8" TEELINE B 111+88.48, 92.94' LT(To Be Killed)
7' Lt.
Ex. 8" Water
114+00 115+00FL 16"=567.40FL 20"=567.23 FL 16" = 570.21 FL 16" = 572.71 FL 16"=567.42 FL 16"=567.46FL 6"=568.13FL 16"=567.71 AT PIPE CL
PROP. GROUND1-16" GATE VALVE1-16"x6" TEEINSTALL:LINE C 114+50.00, 40.00' RTAT PIPE CL
EX. GROUNDBEGIN 16" PVC WATER LINE C1-16" GATE VALVE1-20"x16" TEEINSTALL:CONNECT TO EX. 20" WATER (W)LINE C 113+81.36, 40.00' RT(+) 0.10%
(+) 5.00%PULL PIPE (UP)LINE C 114+45.00, 40.00' RTFL 10" 572.28
W/ 18" ENCASEMENT
PROP. 10" WW FL BOX 576.99
PROP. 5'X4' BOX CULVERT
CL McKINNEY STREET
McKINNEY STREET
MATCHLINE STA 110+50261MATCHLINE STA 110+50N MAYHI
LL ROADS MAYHI
LL ROADMATCHLINE STA 115+50MATCHLINE STA 115+5016" WATER LINE C
1-16" GATE VALVE
6 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-16"x6" TEE
INSTALL:
114+50.00, 40.00' RT
EX. R.O.W
EX. R.O.W
EX. R.O.W
EX. R.O.W
EX. FH
REMOVE & DELIVER
585
580
575
590
565
595
570
585
580
575
590
565
595
570
585
580
575
590
565
595
570
585
580
575
590
565
595
570
E McKINNEY STREET (200' STRIP)
BCI REAL ESTATE VENTURES, LP
LOT 151 (PT)
20" WATER LINE B
256SEE SHEET
12" WATER LINE A 40'1-20" 45°H. BEND
INSTALL:
111+63.32, 37.01' LT
EX. 8" WATER
CUT & PLUG
BEGIN 16" D.I. WATER LINE C
1-16" GATE VALVE
1-20"x16" TEE
INSTALL:
CONNECT TO EX. 20" WATER (W)
113+81.36, 40.00' RT37'1-20" 45°COMBO. BEND
INSTALL:
111+86.35, 67.91' LT
1-20" 11.25°V. BEND
INSTALL:
111+84.31, 76.94' LT
REFERENCE ONLY
McKINNEY STREET
3919/3921 E
HOLDINGS, LLC
NSA PROPERTY
LOT 1R
END 20" D.I. WATER LINE B
CONNECT TO EX. 20 WATER (E)
1-20" GATE VALVE
1-20" 90° H. BEND
INSTALL:
REMOVE EX. 20" PLUG
111+81.09, 91.25' LTEX. 8" WATER TO BE KILLED
20" DUCTILE IRON CLASS 52 WATER
INSTALL 176 LF
CLASS B-3 EMBEDMENT
AWWA CLASS 52
169 LF 16" DUCTILE IRON
16" WATER LINE C
CLASS B-3 EMBEDMENT
AWWA CLASS 52
176 LF 20" DUCTILE IRON
20" WATER LINE B
16" DUCTILE IRON CLASS 52 WATER
INSTALL 169 LF
EX. 16" WATER TO BE KILLED
WASTEWATER DESIGN CRITERIA
PER CITY OF DENTON
(MINIMUM 18")
1/2" STEEL ENCASEMENT PIPE
100 LF
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT12.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT12.dgn1:404:44:33 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
16" WATER LINE C
WATER PLAN & PROFILE
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
LOT 151 (PT)
E McKINNEY STREET (200' STRIP)
BCI REAL ESTATE VENTURES, LP
LOT 159
4301 E McKINNEY STREET
CITY OF DENTON
LOT 154
4393 E McKINNEY STREET
KENNETH L & GLADYS F STOUT
WV16" W 16" W 16" W
8" W 8" W
8" WW 8" WW
15" CMP 15" CMP
PC 116+81.83116+00 117+00 118+00 119+0018"5'X2' RCB5'X2' RCB 5'X2' RCB
18" RCP
RCP
24"
16" W 16" W 16" W
SLEEVES6" PVC
116+00 117+00 118+00 119+00FL 6" = 575.26FL 16" = 574.84 FL 16" = 574.49 FL 16" = 575.19 FL 16" = 575.54 FL 16" = 575.89 FL 16" = 576.24 FL 16" = 572.71 FL 16" = 574.14 FL 16" = 573.96AT PIPE CL
PROP. GROUND1-16" GATE VALVE1-16"x6" TEEINSTALL:LINE C 117+00.00, 40.00' RTAT PIPE CL
EX. GROUND
(+) 5.00%(+) 0.70%PULL PIPE (DOWN)LINE C 115+75.00, 40.00' RTMcKINNEY STREET
MATCHLINE STA 115+50262MATCHLINE STA 115+50
F.L. XXXT.C. XXXCL 10' REC. INLETPAV STA 117+31.37, 39.50' RT
16" WATER LINE C
1-16" GATE VALVE
6 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-16"x6" TEE
INSTALL:
117+00.00, 40.00' RT
DEG = 0° 30' 06.17"
CURVE 1 (CV C-1)
= 4° 14' 00.00" RT
CV C-1
EX. R.O.W
EX. R.O.W
EX. FH
REMOVE & DELIVER
585
580
575
590
565
595
570
PC CV C-1
116+81.87 LINE C
PI STA = 121+05.43, 40.00' RT
N = 7127019.18
E = 2403833.70
T = 422.08'
L = 843.77'
R = 11,420.00'
PC STA = 116+81.87, 40.00' RT
PT STA = 125+28.60, 40.00' RT
585
580
575
590
565
595
570
CL McKINNEY STREET
40'MATCHLINE STA 119+00MATCHLINE STA 119+00REFERENCE ONLY
LOT 161
STREET
4515 E McKINNEY
GLADYS F STOUT
KENNETH L &
LOT 151 (PT)
BAYLOR UNIVERSITY
16" DUCTILE IRON CLASS 52 WATER
INSTALL 350 LF
EX. 16" WATER TO BE KILLED
CLASS B-3 EMBEDMENT
350 LF 16" DUCTILE IRON AWWA CLASS 52
16" WATER LINE C
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT13.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT13.dgn1:404:44:35 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
16" WATER LINE C
WATER PLAN & PROFILE
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
PBX
585.19
5/8" IRS W/RANDOM
34
BAYLOR UNIVERSITY
4515 E McKINNEY STREET
KENNETH L & GLADYS F STOUT
LOT 161
4663 E McKINNEY STREET
MEMORIAL BAPTIST CHURCH OF DENTON
(OLD DCAD 1P, 1P2, 1R), AC
LOT 162, 163, 164
DOC # 99-R0026679
EASEMENT
20' PUBLIC UTILITY
FM
16" W 16" W
8" W
8" WW
8" WW
15" CMP 15" CMP
16" W
119+00 120+00 121+00
5'X2' RCB
24" RCP 24" RCP
5'X2' RCB18"
16" W 16" W
SLEEVES
6" PVC 6" PVC SLEEVES
119+00 120+00 121+00FL 6" = 575.36FL 16" = 576.94 FL 16" = 576.24 FL 16" = 576.59 FL 16" = 576.94 FL 16" = 577.29 FL 16" = 577.64 FL 16" = 577.99 AT PIPE CL
PROP. GROUND
AT PIPE CL
EX. GROUND1-16" GATE VALVE1-16"x6" TEEINSTALL:LINE C 120+00.00, 40.00' RT(+) 0.70%
EX. FIBER EX. FIBER
McKINNEY STREET
MATCHLINE STA 121+50MATCHLINE STA 121+50263
CV C-1
16" WATER LINE C
40'EX. R.O.W
EX. R.O.W
BAYLOR UNIVERSITY
LOT 151 (PT)MATCHLINE STA 119+00MATCHLINE STA 119+00DEG = 0° 30' 06.17"
CURVE 1 (CV C-1)
= 4° 14' 00.00" RT
PI STA = 121+05.43, 40.00' RT
N = 7127019.18
E = 2403833.70
T = 422.08'
L = 843.77'
R = 11,420.00'
PC STA = 116+81.87, 40.00' RT
PT STA = 125+28.60, 40.00' RT
1-16" GATE VALVE
6 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-16"x6" TEE
INSTALL:
120+00.00, 40.00' RT
585
580
575
590
595
570
600
585
580
575
590
595
570
600
END WORK TO BE DONE BY OTHERS
BEGIN WORK THIS CONTRACT
STA 119+50
CL McKINNEY STREET
16" DUCTILE IRON CLASS 52 WATER
INSTALL 149 LF
EX. 16" WATER TO BE KILLED
CLASS B-3 EMBEDMENT
149 LF 16" DUCTILE IRON AWWA CLASS 52
16" WATER LINE C
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT14.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT14.dgn1:404:44:37 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
16" WATER LINE C
WATER PLAN & PROFILE
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
PBX
8" HACKBERRY
DBL. 15"/24" PECAN24" PECAN
27" PECANDBL. 18" ELM
15" PECAN
TRI 12" PECAN
30" PECAN
DBL. 8" TREEDBL. 8"/15" TREE
S
BAYLOR UNIVERSITY
4673 E McKINNEY STREET
MEMORIAL BAPTIST CHURCH OF DENTON
4683 E McKINNEY STREET
SAYR RESOURCES INC
LOT 151 (PT)
LOT 166 LOT 167
(OLD DCAD 1P, 1P2, 1R), AC
LOT 162, 163, 164
4663 E McKINNEY STREET
MEMORIAL BAPTIST CHURCH OF DENTON
BCI REAL ESTATE VENTURES,LP
LOT 151 (PT)
VOL. 5039, PG. 01056
EASEMENT
8' PUBLIC UTILITY
VOL. 5039, PG. 01056
EASEMENTCONSTRUCTION
20' TEMPORARY
VOL. 5039, PG. 01056
EASEMENT
20' PUBLIC UTILITY
WV
WV 16" W 16" W
8" W
8" W
8" WW 8" WW 8" WW
18" CMP 15" RCP 15" RCP
PT 125+28.65122+00 123+00 124+00 125+00 126+00
5'X2' RCB 36" RCPRCB
5'X3'
16" W16" W 16" W 16" W
6" PVC SLEEVES
6" PVC SLEEVES122+00 123+00 124+00 125+00 126+00FL 6" = 579.46FL 16" = 579.04FL 6" = 580.01FL 16" = 579.59 FL 16" = 577.99 FL 16" = 578.34 FL 16" = 578.69 FL 16" = 579.39 FL 16" = 579.66 FL 16" = 579.79 FL 16" = 579.76 FL 16" = 579.34 1-16" GATE VALVE1-16"x6" TEEINSTALL:LINE C 123+00.00, 40.00' RT1-16" GATE VALVE1-16"x6" TEEINSTALL:LINE C 125+50.00, 40.00' RTAT PIPE CL
EX. GROUND
AT PIPE CL
PROP. GROUND 1-TYPE 1 AIR RELEASE VALVEINSTALL:LINE C 124+50.00, 40.00' RT200' V.C.
(+) 0.70%(-) 0.50%
McKINNEY STREET
MATCHLINE STA 121+50MATCHLINE STA 121+50MATCHLINE STA 126+00264MATCHLINE STA 126+00CV C-1
16" WATER LINE C
1-16" GATE VALVE
6 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-16"x6" TEE
INSTALL:
123+00.00, 40.00' RT
1-16" GATE VALVE
6 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-16"x6" TEE
INSTALL:
125+50.00, 40.00' RT40'PT CV C-1
125+28.60 LINE C
EX. R.O.W
CL McKINNEY STREET
EX. R.O.W
DEG = 0° 30' 06.17"
CURVE 1 (CV C-1)
= 4° 14' 00.00" RT
PI STA = 121+05.43, 40.00' RT
N = 7127019.18
E = 2403833.70
T = 422.08'
L = 843.77'
R = 11,420.00'
PC STA = 116+81.87, 40.00' RT
PT STA = 125+28.60, 40.00' RT
BELOW STORM DRAIN
LOWERING
EX. 8" WATER MAIN
585
580
575
590
595
570
600
585
580
575
590
595
570
600
STANDARD DRAWING W801
PER CITY OF DENTON
1-TYPE I AIR RELEASE VALVE
INSTALL:
124+50.00, 40.00' RT
16" DUCTILE IRON CLASS 52 WATER
INSTALL 448 LF
EX. 16" WATER TO BE KILLED
CLASS B-3 EMBEDMENT
448 LF 16" DUCTILE IRON AWWA CLASS 52
16" WATER LINE C
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT15.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT15.dgn1:404:44:40 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
16" WATER LINE C
WATER PLAN & PROFILE
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PBX
36" TREE
36" PECAN
2" TREE
36" PECAN
2" TREE
48" PECAN
DBL. 4"/15" HACKBERRY
6" HACKBERRY
21" CEDARDBL. 15"/24" PECAN
S
586.97
5/8" IRS W/RANDOM
35
BCI REAL ESTATE VENTURES,LP
5001 E McKINNEY STREET
BARBARA McDONALD COBB
LOT 151 (PT)
LOT 168 LOT 169
5043 E McKINNEY STREET
CHELA DARLINE McDONALD
VOL. 5039, PG. 01056
EASEMENTCONSTRUCTION
20' TEMPORARY
VOL. 5039, PG. 01056
EASEMENT
20' PUBLIC UTILITY DOC
#
9
9
-R00773
0
9
2
0' PUBLI
C UTI
LI
TY EASEMENTSTREET
5043 E McKINNEY
McDONALD
CHELA DARLINE
VOL. 5039, PG. 01056
EASEMENT
8' PUBLIC UTILITY
FM
16" W 16" W
8" WW
8
"
WW6" W
6
" W6
" W8" W
15" RCP
15" RCP
21" RCP 21" RCP 21" RCP
PC 129+61.61126+00 127+00 128+00 129+00 130+00
D
18" RCP18" RCP36"
R
C
P
18" RCP
36" RCP
36" RCP18"18" RCPD
36" RCP
RCP
24"
4'x3' RCB
16" W 16" W 16" W 16" W 16" W
SLEEVES
6" PVC
SLEEVES
6" PVC
SLEEVES
6" PVC
SLEEVES
6" PVC
SLEEVES
6" PVC
126+00 127+00 128+00 129+00 130+00FL 6" = 578.76FL 16" = 578.34 FL 16" = 579.34 FL 16" = 579.09 FL 16" = 578.84 FL 16" = 578.59 FL 16" = 578.09 FL 16" = 577.84 FL 16" = 577.59 FL 16" = 577.34 1-16" GATE VALVE1-16"x6" TEEINSTALL:LINE C 128+00.00, 40.00' RTAT PIPE CL
EX. GROUND
AT PIPE CL
PROP. GROUND
(-) 0.50%
EX. FIBER EX. FIBER
McKINNEY STREET
MATCHLINE STA 126+00MATCHLINE STA 126+00265MATCHLINE STA 126+00MATCHLINE STA 130+00ROADN CARPENTER
CV C-2
16" WATER LINE C
1-16" GATE VALVE
6 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-16"x6" TEE
INSTALL:
128+00.00, 40.00' RT
EX. R.O.W.
EX. R.O.W
PC CV C-2
129+61.61 LINE C
40'McKINNEY STREET
DEG = 0° 55' 21.49"
CURVE 2 (CV C-2)
= 9° 48' 00.00" RT
PI STA = 134+97.42, 40.00' RT
N = 7126579.72
E = 3404149.74
T = 532.38'
R = 6,210.00'
PC STA = 129+61.61, 40.00' RT
PT STA = 140+30.62, 40.00' RT
L = 1,062.17'
EX. R.O.W.
585
580
575
590
595
570
600
585
580
575
590
595
570
600
16" DUCTILE IRON CLASS 52 WATER
INSTALL 400 LF
EX. 16" WATER TO BE KILLED
CLASS B-3 EMBEDMENT
400 LF 16" DUCTILE IRON AWWA CLASS 52
16" WATER LINE C
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT16.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT16.dgn1:404:44:42 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
16" WATER LINE C
WATER PLAN & PROFILE
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
CONCRETE
PBX
E
5101 E McKINNEY STREET
DENTON ISD
5090 E McKINNEY STREET
EDIBERTO A RODRIGUEZ
LOT 1R4
LOT 150
BCI REAL ESTATE VENTURES,LP
LOT 151 (PT)
E McKINNEY STREET
KIM Y PHAM
LOT 1
CAB. H, PG. 62
20' UTILITY EASEMENT
CAB. E, PG. 330
4' SIDEWALK EASEMENT
LOT 169
STREET
5043 E McKINNEY
McDONALD
CHELA DARLINE
WV
WV
WVFM
16" W 16" W
16" W
8" W
8" W 8" W10" W10" W
10" W
24" RCP
27" RCP
15"
R
C
P
24"
R
C
P
27" RCP 27" RCP
2-48" RCP24"
R
CPRCBCEX.9'X6'
130+00 131+00 132+00 133+00 134+00
135+00
BOX CULVERT3-6'x3'D18"
30" RCP 24" RCP18"18" RCP36" RCP36" RCP36" RCP24" RCP24"24"18"RCB
5'X3'
18" RCP
4'X3' RCB
4'X3' RCB
16" W 16" W 16" W
16" W
1
0
" W6" PVC SLEEVES
6" PVC SLEEVES
130+00 131+00 132+00 133+00 134+00 135+00FL 6" = 577.38FL 16" = 576.96FL 6" = 577.93FL 16" = 577.51 FL 16"=575.99FL 16"=572.88FL 16"=572.93FL 16"=577.49FL 16" = 577.34 FL 16" = 577.09 FL 16" = 576.84 FL 16" = 576.59 FL 16" = 576.34 FL 16" = 576.09 FL 16" = 572.90 FL 16" = 577.61 FL 16" = 577.71 FL 16" = 577.81 1-16" GATE VALVE1-16"x6" TEEINSTALL:LINE C 130+75.00, 40.00' RT1-16" GATE VALVE1-16"x6" TEEINSTALL:LINE C 133+50.00, 40.00' RTAT PIPE CL
EX. GROUND
AT PIPE CL
PROP. GROUND 1-16" 22.5°V. BENDINSTALL:LINE C 132+70.00, 40.00' RT1-16" 22.5°V. BENDINSTALL:LINE C 133+25.00, 40.00' RT1-16" 22.5°V. BENDINSTALL:LINE C 133+36.00, 40.00' RT(-) 0.50%(-) 41.42
%(+) 0.10%(+) 41.42%(+) 0.20%
FL BOX 577.37
PROP. 3-6'X3' BOX CULVERT1-16" 22.5°V. BENDINSTALL:LINE C 132+80.00, 40.00' RTMcKINNEY STREET
MATCHLINE STA 130+00266MATCHLINE STA 135+00MATCHLINE STA 130+00MATCHLINE STA 135+00RYAN WAYCV C-2
16" WATER LINE C
40'40'McKINNEY STREET
1-16" GATE VALVE
6 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-16"x6" TEE
INSTALL:
130+75.00, 40.00' RT
1-16" GATE VALVE
6 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-16"x6" TEE
INSTALL:
133+50.00, 40.00' RT
EX. R.O.W.
DEG = 0° 55' 21.49"
CURVE 2 (CV C-2)
= 9° 48' 00.00" RT
PI STA = 134+97.42, 40.00' RT
N = 7126579.72
E = 3404149.74
T = 532.38'
R = 6,210.00'
PC STA = 129+61.61, 40.00' RT
PT STA = 140+30.62, 40.00' RT
L = 1,062.17'
EX. R.O.W.
1-16" 22.5°V. BEND
INSTALL:
132+70.00, 40.00' RT
1-16" 22.5°V. BEND
INSTALL:
133+36.00, 40.00' RT
1-16" 22.5°V. BEND
INSTALL:
133+25.00, 40.00' RT
585
580
575
590
595
570
565
585
580
575
590
595
570
565
BEGIN PROP. 12" WATER LINE ACONNECT TO EX. 8 WATER (W)1-12" GATE VALVE1-12" 22.5° H. BEND1-12"x8" REDUCERINSTALL:90+65.00, 53.93' RT
STORM
BELOW PROP.
WATER MAIN
LOWER EX. 8"
CUT & PLUG EX. 10" WATER
43 LF 10" D.I. WATER
2-10" 22.5° H. BENDS
1-10" GATE VALVE
1-10"x8" TEE
INSTALL:
131+88.33, 51.91' LT
STORM
BELOW PROP.
WATER MAIN
LOWER EX. 8"
16" DUCTILE IRON CLASS 52 WATER
INSTALL 497 LF
EX. 16" WATER TO BE KILLED
CLASS B-3 EMBEDMENT
497 LF 16" DUCTILE IRON AWWA CLASS 52
16" WATER LINE C
1-16" 22.5°V. BEND
INSTALL:
132+80.00, 40.00' RT
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT17.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT17.dgn1:404:44:45 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
16" WATER LINE C
WATER PLAN & PROFILE
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
E
587.02
5/8" IRS W/RANDOM36
5101 E McKINNEY STREET
DENTON ISD
E McKINNEY STREET
KIM Y PHAM
LOT 1R4
LOT 1
CAB. H, PG. 62
20' UTILITY EASEMENT
CAB. E, PG. 330
4' SIDEWALK EASEMENT
WV
10" W 10" W
16" W
16" W
16" W
24" RCP
135+00 136+00 137+00 138+00 139+00
18" RCP
24" RCP
18" RCP
16" W 16" W 16" W
6" PVC SLEEVES
135+00 136+00 137+00 138+00 139+00FL 6" = 578.53FL 16" = 578.11 FL 16" = 577.81 FL 16" = 577.91 FL 16" = 578.01 FL 16" = 578.21 FL 16" = 578.31 FL 16" = 578.41 FL 16" = 578.51 FL 16" = 578.61 AT PIPE CL
EX. GROUND
AT PIPE CL
PROP. GROUND
1-16" GATE VALVE1-16"x6" TEEINSTALL:LINE C 136+50.00, 40.00' RT(+) 0.20%
SIGNAL CABLE
EX. TRAFFIC
McKINNEY STREET
MATCHLINE STA 135+00267MATCHLINE STA 139+00MATCHLINE STA 135+00MATCHLINE STA 139+00CV C-2
16" WATER LINE C
McKINNEY STREET
EX. R.O.W.
EX. R.O.W.
1-16" GATE VALVE
6 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-16"x6" TEE
INSTALL:
136+50.00, 40.00' RT 40'EX. FH
REMOVE & DELIVER
E McKINNEY STREET
KIM Y PHAM
LOT 1
DEG = 0° 55' 21.49"
CURVE 2 (CV C-2)
= 9° 48' 00.00" RT
PI STA = 134+97.42, 40.00' RT
N = 7126579.72
E = 3404149.74
T = 532.38'
R = 6,210.00'
PC STA = 129+61.61, 40.00' RT
PT STA = 140+30.62, 40.00' RT
L = 1,062.17'
585
580
575
590
595
570
600
585
580
575
590
595
570
600
16" DUCTILE IRON CLASS 52 WATER
INSTALL 397 LF
EX. 16" WATER TO BE KILLED
CLASS B-3 EMBEDMENT
397 LF 16" DUCTILE IRON AWWA CLASS 52
16" WATER LINE C
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT18.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT18.dgn1:404:44:47 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
16" WATER LINE C
WATER PLAN & PROFILE
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
V
E
ES
592.87
5/8" IRS W/RANDOM
37
5101 E McKINNEY STREET
DENTON ISD
E McKINNEY STREET
KIM Y PHAM
E McKINNEY STREET
KIM Y PHAM
LOT 1R4
LOT 1, BLOCK A LOT 1, BLOCK B
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
LOT 1
CAB. H, PG. 62
20' UTILITY EASEMENT
CAB. H, PG. 62
16' UTILITY EASEMENT
CAB. E, PG. 60
16' UTILITY EASEMENT
C
AB. H,
P
G.
6
2
1
6'
U
TI
LI
T
Y
E
AS
E
ME
NT
CAB. E, PG. 330
EASEMENT
4' SIDEWALK
CAB. E, PG. 330
4' SIDEWALK EASEMENT
WV WV
WVWV
WV
WV
WVWV
FM
10" W 10" W
16" W 16" W 16" W 16" W16" W8" W8" W10" WW
10" WW
10" WW10"WW16" W
(
F
O
R
C
E MAI
N)
8" WW8" WW8" W PT 140+30.62139+00 140+00 141+00 142+00 143+00
D18"24" RCP
18"RCP
16" W 16" W 16" W 16" W16 " W16" W16" W 16" W
16" W
6" PVC SLEEVES
SLEEVES
6" PVC 6" PVC SLEEVES139+00 140+00 141+00 142+00 143+00FL 6" = 579.14FL 16" = 578.72FL 6" = 583.78FL 16" = 583.36 FL 16" = 584.36 FL 16" = 584.36 FL 16" = 584.56FL 16" = 578.86FL 16" = 578.61 FL 16" = 578.71 FL 16" = 578.81 FL 16" = 579.36 FL 16" = 580.36 FL 16" = 581.36 FL 16" = 582.36 FL 8" = 579.16FL 16" = 578.831-16" GATE VALVE1-16"x6" TEEINSTALL:LINE C 139+55.00, 40.00' RT1-16" GATE VALVE1-16"x8" TEEINSTALL:LINE C 140+10.42, 40.00' RT1-16" GATE VALVE1-16"x6" TEEINSTALL:LINE C 142+50.00, 40.00' RT1-16" GATE VALVE1-16"x16" TEEINSTALL:LINE C 143+00.00, 40.00' RTEND 16" D.I. WATER LINE C1-16" PLUGINSTALL:LINE C 143+10.00, 40.00' RTAT PIPE CL
EX. GROUND
AT PIPE CL
PROP. GROUNDPULL PIPE (DOWN)LINE C 140+25.00, 40.00' RTWASTEWATER DESIGN CRITERIA
PER CITY OF DENTON
(MINIMUM 18")
1/2" STEEL ENCASEMENT PIPE
(+) 0.20%(+) 2.00%
(+) 2.00%
EX. FIBER
EX. CCTV
EX. GASEX. CCTV EX. FIBER
FL 10" 582.01+/-
EX. 10" WW
FL 16" 581.98+/-
(TO BE KILLED)
EX. 16" WATER
McKINNEY STREET
MATCHLINE STA 139+00268MATCHLINE STA 139+00WAYGLENNGARY
CV C-2
16" WATER LINE C
PT CV C-2
140+30.62 LINE C
1-16" GATE VALVE
22 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-16"x6" TEE
INSTALL:
139+55.00, 40.00' RT
1-16" GATE VALVE
6 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-16"x6" TEE
INSTALL:
142+50.00, 40.00' RT
CONNECT TO EX. 8" WATER (S)
16 LF 8" PVC WATER
1-16" GATE VALVE
1-8" GATE VALVE
1-16"x8" TEE
INSTALL:
REMOVE EX. 16"x8" TEE
140+10.46, 40.00' RT
269SEE SHEET
16" WATER LINE D
16"x16" TEE (N)
CONNECT TO PROP.
77 LF 16" D.I. WATER
2-16" GATE VALVES
1-16"x16" TEE
INSTALL:
143+00.00, 40.00' RT
END 16" D.I. WATER LINE C
1-16" PLUG
INSTALL:
143+10.00, 40.00' RT
McKINNEY STREET
EX. R.O.W.
EX. R.O.W.40'EX. FH
REMOVE & DELIVER
EX. FH
REMOVE & DELIVER
EX. 16" WATER
CUT & PLUG
EX. 16" WATER
CUT & PLUG
DEG = 0° 55' 21.49"
CURVE 2 (CV C-2)
= 9° 48' 00.00" RT
PI STA = 134+97.42, 40.00' RT
N = 7126579.72
E = 3404149.74
T = 532.38'
R = 6,210.00'
PC STA = 129+61.61, 40.00' RT
PT STA = 140+30.62, 40.00' RT
L = 1,062.17'
E McKINNEY STREET
KIM Y PHAM
LOT 1, BLOCK B
585
580
575
590
595
600
605
585
580
575
590
595
600
605
WASTEWATER DESIGN CRITERIA
PER CITY OF DENTON
(MINIMUM 18")
1/2" STEEL ENCASEMENT PIPE
18 LF 6" PVC SLEEVESWATER DESIGN CRITERIA
PER CITY OF DENTON
(MINIMUM 18")
1/2" STEEL ENCASEMENT PIPE
70 LF
16" DUCTILE IRON CLASS 52 WATER
INSTALL 409 LF
EX. 16" WATER TO BE KILLED
CLASS B-3 EMBEDMENT
409 LF 16" DUCTILE IRON AWWA CLASS 52
16" WATER LINE C
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT19.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT19.dgn1:404:44:49 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
16" WATER LINE D
WATER PLAN & PROFILE
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
V
E
ES
592.87
5/8" IRS W/RANDOM
37
5101 E McKINNEY STREET
DENTON ISD
E McKINNEY STREET
KIM Y PHAM
E McKINNEY STREET
KIM Y PHAM
LOT 1R4
LOT 1, BLOCK A LOT 1, BLOCK B
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
LOT 1
CAB. H, PG. 62
20' UTILITY EASEMENT
CAB. H, PG. 62
16' UTILITY EASEMENT
CAB. E, PG. 60
16' UTILITY EASEMENT
C
AB. H,
P
G.
6
2
1
6'
U
TI
LI
T
Y
E
AS
E
ME
NT
CAB. E, PG. 330
EASEMENT
4' SIDEWALK
CAB. E, PG. 330
4' SIDEWALK EASEMENT
WV WV
WVWV
WV
WV
WVWV
FM
10" W 10" W 10" W
16" W 16" W 16" W 16" W16" W8" W8" W10" WW
10" WW
10" WW10"WW16" W
(
F
O
R
C
E MAI
N)
8" WW8" WW8" W PT 140+30.62139+00 140+00 141+00 142+00 143+00
D
18" RCP 18"24" RCP
18"RCP
16" W 16" W 16" W 16" W 16" W16 " W16" W16" W 16" W
16" W
6" PVC SLEEVES
SLEEVES
6" PVC 6" PVC SLEEVES142+00 143+00FL 16" = 585.00 FL 16" = 584.00 FL 16" = 585.50FL EX. 10" = 585.50FL 8" = 585.09FL 16" = 584.76FL 16" = 584.50 FL 16" = 584.50Ex. 10" Water 1-16" GATE VALVE1-16"x8" TEEINSTALL:LINE D 142+73.56, 37.00' LT1-16" GATE VALVE1-16"x16" TEEINSTALL:LINE D 143+00.00, 37.00' LTAT PIPE CL
EX. GROUND
AT PIPE CL
PROP. GROUNDBEGIN 16" D.I. WATER LINE DCONNECT TO EX. 10" WATER1-10" GATE VALVE1-16" 45° H. BEND1-16"x10" REDUCERINSTALL:LINE D 142+00.00, 48.77' LT1-12" 45°H. BENDINSTALL:LINE D 142+11.35, 37.00' LT(-) 1.00%
EX. CCTV EX. CCTV
FL 16" 585.48+/-
(TO BE KILLED)
EX. 16" WATER
McKINNEY STREET
269MATCHLINE STA 143+50MATCHLINE STA 143+50WAYGLENNGARY
16" WATER LINE D
268SEE SHEET
16" WATER LINE C
EX. R.O.W.37'EX. R.O.W.
McKINNEY STREET
E McKINNEY STREET
KIM Y PHAM
LOT 1, BLOCK A
CONNECT TO EX. 8" WATER (N)
1-16" GATE VALVE
5 LF 8" PVC WATER
1-8" GATE VALVE
1-16"x8" TEE
INSTALL:
142+73.56, 37.00' LT
D.I. WATER (S)
CONNECT TO PROP. 16"
1-16" GATE VALVE
1-16"x16" TEE
INSTALL:
143+00.00, 37.00' LT
1-12" 45°H. BEND
INSTALL:
142+11.35, 37.00' LT
BEGIN 16" D.I. WATER LINE D
CONNECT TO EX. 10" WATER (W)
1-10" GATE VALVE
1-16" 45° H. BEND
1-16"x10" REDUCER
INSTALL:
142+00.00, 48.77' LT
EX. R.O.W.
585
580
575
590
595
600
605
585
580
575
590
595
600
605
WATER DESIGN CRITERIA
PER CITY OF DENTON
(MINIMUM 18")
1/2" STEEL ENCASEMENT PIPE
70 LF
16" DUCTILE IRON CLASS 52 WATER
INSTALL 155 LF
EX. 16" WATER TO BE KILLED
CLASS B-3 EMBEDMENT
155 LF 16" DUCTILE IRON AWWA CLASS 52
16" WATER LINE D
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT20.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT20.dgn1:404:44:52 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
16" WATER LINE D
WATER PLAN & PROFILE
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
S
E McKINNEY STREET
KIM Y PHAM
E McKINNEY STREET
ATMOS ENERGY CORP
LOT 1
LOT 147B
LOT 1, BLOCK B
CAB. E, PG. 60
16' UTILITY EASEMENT
CAB. E, PG. 330
EASEMENT
4' SIDEWALK
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
FM
T
16" W 16" W 16" W
8" WW 8" WW 8" WW
18" RCP
8" WW6" WW144+00 145+00 146+00 147+00 148+00
D18"RCP18"18" RCP
16" W 16" W 16" W 16" W
SLEEVES
6" PVC
144+00 145+00 146+00 147+00 148+00FL 16" = 584.00 FL 16" = 583.50 FL 16" = 583.00 FL 16" = 582.00 FL 16" = 581.00 FL 16" = 580.00 FL 16" = 579.70 FL 16" = 579.40 FL 16" = 579.10 FL 16" = 578.80 FL 6" = 580.92FL 16" = 580.501-16" GATE VALVE1-16"x6" TEEINSTALL:LINE D 145+75.00, 37.00' LTAT PIPE CL
EX. GROUND
AT PIPE CL
PROP. GROUND
(-) 1.00%(-) 2.00%
(-) 2.00%(-) 0.60%PULL PIPE (DOWN)LINE D 144+50.00, 37.00' LTPULL PIPE (UP)LINE D 146+00.00, 37.00' LTMcKINNEY STREET
MATCHLINE STA 143+50270MATCHLINE STA 148+00MATCHLINE STA 143+50MATCHLINE STA 148+0016" WATER LINE D
EX. R.O.W.
McKINNEY STREET
EX. R.O.W.
1-16" GATE VALVE
9 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-16"x6" TEE
INSTALL:
145+75.00, 37.00' LT
37'585
580
575
590
595
600
570
585
580
575
590
595
600
570
16" DUCTILE IRON CLASS 52 WATER
INSTALL 450 LF
EX. 16" WATER TO BE KILLED
CLASS B-3 EMBEDMENT
450 LF 16" DUCTILE IRON AWWA CLASS 52
16" WATER LINE D
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT21.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT21.dgn1:404:44:54 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
16" WATER LINE D
WATER PLAN & PROFILE
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
CONCRETE
S S
S
582.48
X CUT SET
38
E McKINNEY STREET
ATMOS ENERGY CORP
LOT 147B
CAB. E, PG. 60
16' UTILITY EASEMENT
CAB. E, PG. 60
16' UTILITY EASEMENT
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
LOT 1 LOT 1
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
WV
WV
FMFM
16" W
16" W
8" WW 8" WW
12" WW12" W W
8" WW 8" WW
16" W
18" RCP BOX CULVERT4.35'x4'3-
3
6
" CMP
8" WW 6" WW8" WW
RCBEX.3-6'x3' PC 152+46.66148+00 149+00 150+00 151+00 152+00
18" RCP 18" RCP18"24" RCP 24" RCP 18" RCP24" RCP24" RCP18" RCPCULVERTBOX 3-7'x3'16" W 16" W 16" W
16" W
6" PVC SLEEVES
12" WW0+001+00148+00 149+00 150+00 151+00 152+00FL 16" = 578.80 FL 16" = 578.20 FL 16" = 577.90 FL 16" = 577.60 FL 16" = 576.18 FL 16" = 574.76FL 16" = 571.76FL 6" =578.92FL 16" = 578.50 FL 6" = 575.18FL 16" = 574.76 FL 16" = 571.65FL 16" = 576.15FL 8" = 567.90FL 16" = 567.57 FL 16" = 574.86 FL 16" = 574.81 FL 16" = 571.70 FL 16" = 574.911-16" GATE VALVE1-16"x6" TEEINSTALL:LINE D 148+50.00, 37.00' LT1-16" GATE VALVE1-16"x8" TEEINSTALL:LINE D 148+92.80, 37.00' LT1-16" GATE VALVE1-16"x6" TEEINSTALL:LINE D 151+50.00, 37.39' LTAT PIPE CL
EX. GROUND
AT PIPE CL
PROP. GROUND
1.50° LEFTPULL PIPELINE D 151+35.00, 37.00' LT(-
) 100.
0
0%(+) 100.00%(+) 0.30%
(-) 0.60%1-16" 45°V. BENDINSTALL:LINE D 151+55.00, 37.52' LT1-16" 45°V. BENDINSTALL:LINE D 151+58.00, 37.65' LT1-16" 45°V. BENDINSTALL:LINE D 152+42.00, 39.80' LT(-) 0.60%(-) 41.42
%(-) 0.10%(-) 0.10%
(-) 0.13%(-) 0.13%1-16" 22.5°V. BENDINSTALL:LINE D 150+00.00, 37.00' LT1-16" 22.5°V. BENDINSTALL:LINE D 150+06.50, 37.00' LTEX. CCTV
EX. CCTV FL 24" 578.89
PROP. 24" RCP
FL 18" 578.47
PROP. 18" RCP
FL BOX 576.94
PROP. 3-7'X3' BOX CULVERT
FL 12" 571.75
W/ 20" STEEL ENCASEMENT
PROP. 12" WW 1-16" 45°V. BENDINSTALL:LINE D 152+35.00, 39.62' LTMcKINNEY STREET
MATCHLINE STA 148+00271MATCHLINE STA 152+50MATCHLINE STA 148+00MATCHLINE STA 152+5016" WATER LINE D DRIVES FORK McKINNEY STREET
EX. R.O.W.
EX. R.O.W.37'1-16" GATE VALVE
9 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-16"x6" TEE
INSTALL:
148+50.00, 37.00' LT
1-16" GATE VALVE
9 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-16"x6" TEE
INSTALL:
151+50.00, 37.39' LT
CONNECT TO EX. 8" WATER (N)
1-16" GATE VALVE
1-16"x8" TEE
INSTALL:
148+92.80, 37.00' LT
1.50° LEFT
PULL PIPE
151+35.00, 37.00' LT
EX. R.O.W.
1-16" 45°V. BEND
INSTALL:
151+55.00, 37.52' LT
1-16" 45°V. BEND
INSTALL:
151+58.00, 37.60' LT
1-16" 45°V. BEND
INSTALL:
152+42.00, 39.80' LT
585
580
575
590
595
565
570
585
580
575
590
595
565
570
1-16" 22.5°V. BEND
INSTALL:
150+00.00, 37.00' LT 1-16" 22.5°V. BEND
INSTALL:
150+06.50, 37.00' LT
151+60.00152+30.00WASTEWATER DESIGN CRITERIA
PER CITY OF DENTON
(MINIMUM 20")
1/2" STEEL ENCASEMENT PIPE LIMITS
70 LF
WASTEWATER DESIGN CRITERIA
PER CITY OF DENTON
(MINIMUM 18")
1/2" STEEL ENCASEMENT PIPE
100 LF 151+60.00152+30.00WATER DESIGN CRITERIA
PER CITY OF DENTON
(MINIMUM 18")
1/2" STEEL ENCASEMENT PIPE
70 LF
16" DUCTILE IRON CLASS 52 WATER
INSTALL 450 LF
EX. 16" WATER TO BE KILLED
CLASS B-3 EMBEDMENT
450 LF 16" DUCTILE IRON AWWA CLASS 52
16" WATER LINE D
1-16" 45°V. BEND
INSTALL:
152+35.00, 39.62' LT
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT22.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT22.dgn1:404:44:56 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
16" WATER LINE D
WATER PLAN & PROFILE
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
S
E McKINNEY STREET
ATMOS ENERGY CORP
LOT 147A
E McKINNEY STREET
ATMOS ENERGY CORP
LOT 147B
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
LOT 1
CAB. E, PG. 60
16' UTILITY EASEMENT
FM
8" WW
16" W
16" W
8" WW
8" WW
3'x2' RCB
3'x2' RCB PC 152+46.66 PT 156+32.66153+00
154+00 155+00 156+00
157+00
18" RCP3'x2' RCB
18" RCP
18"
16" W
16" W
16" W
16" W
153+00 154+00 155+00 156+00 157+00FL 16" = 576.18 FL 16" = 576.33 FL 16" = 576.48 FL 16" = 576.63 FL 16" = 576.93 FL 16" = 577.08 FL 16" = 577.23 FL 16" = 577.38 FL 16" = 577.53 FL 6" = 577.20FL 16" = 576.78 1-16" GATE VALVE1-16"x6" TEEINSTALL:LINE D 154+50.00, 39.44' LTAT PIPE CL
EX. GROUND
AT PIPE CL
PROP. GROUND
(+) 0.30%1.50° RIGHTPULL PIPELINE D 152+60.00, 40.32' LTEX. GAS
McKINNEY STREET
MATCHLINE STA 152+50272MATCHLINE STA 157+00MATCHLINE STA 152+50MATCHLINE STA 157+00CV D-1
16" WATER LINE D
DEG = 3° 37' 34.73"
CURVE 1 (CV D-1)
= 9° 39' 00.00" RT
T = 133.37'
L = 266.11'
R = 1,580.00'
PC STA = 152+75.16, 40.46' LT
PT STA = 155+36.68, 36.54' LT
N = 7125745.58
E = 2405870.68
PI STA = 154+06.17, 40.30' LT
PT CV D-1
155+36.68 LINE D
1-16" GATE VALVE
10 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-16"x6" TEE
INSTALL:
154+50.00, 39.44' LT
EX. R.O.W.
EX. R.O.W.34.5'CL McKINNEY STREET
PC CV D-1
152+75.16 LINE D
1.50° RIGHT
PULL PIPE
152+60.00, 40.32' LT
585
580
575
590
595
565
570
585
580
575
590
595
565
570
16" DUCTILE IRON CLASS 52 WATER
INSTALL 457 LF
EX. 16" WATER TO BE KILLED
CLASS B-3 EMBEDMENT
457 LF 16" DUCTILE IRON AWWA CLASS 52
16" WATER LINE D
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT23.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT23.dgn1:404:44:59 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
16" WATER LINE D
WATER PLAN & PROFILE
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
585.97PK NAIL SET39
DD
E McKINNEY STREET
ATMOS ENERGY CORP
E McKINNEY STREET & TRINITY ROAD
THE WOODLANDS ON McKINNEY STREET LLCK
O
R
N
U
P
A
UL
& WE
N
TS
AI
LOT 147A
LOT 143, 144
L
OT 108CAB. E, PG. 60
16' UTILITY EASEMENT
V
O
L. 990, P
G.640
15'
U
TI
LI
T
Y E
ASE
ME
NT
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
LOT 1
16" W 16" W 16" W12" W12" W8" WW
24" RCP 24" RCP 18"18" RCP18"18" RCP24" RCP
D RCP18" D
157+00 158+00 159+00 160+00 161+00
16" W 16" W 16" W 16" W
157+00 158+00 159+00 160+00 161+00FL 16" = 577.53 FL 16" = 577.68 FL 16" = 578.28 FL 16" = 579.18 FL 16" = 580.08 FL 16" = 580.98 FL 16" = 581.88 FL 16" = 582.78 FL 16" = 583.68 FL 16" = 577.92FL 12" = 579.99FL 16" = 579.82 FL 12" = 580.53FL 16" = 580.36FL 6" = 578.25FL 16" = 577.83 FL 6" = 583.56FL 16" = 583.141-16" GATE VALVE1-16"x6" TEEINSTALL:LINE D 158+00.00, 34.50' LT2-16" GATE VALVES1-16"x12" TEEINSTALL:LINE D 159.35.68, 34.50' LT1-16" GATE VALVE1-16"x12" TEEINSTALL:LINE D 159.65.68, 34.50' LT1-16" GATE VALVE1-16"x6" TEEINSTALL:LINE D 161+20.00, 34.50' LTAT PIPE CL
EX. GROUND
AT PIPE CL
PROP. GROUND
(+) 0.30%(+) 1.80%PULL PIPE (UP)LINE D 158+30.00, 34.50' LTWITH 6' OF COVER
1/4" STEEL ENCASEMENT PIPE
EX. 25 LF 24",
McKINNEY STREET
MATCHLINE STA 157+00273MATCHLINE STA 161+50MATCHLINE STA 157+00MATCHLINE STA 161+5016" WATER LINE D
EX. R.O.W.
EX. R.O.W.
1-16" GATE VALVE
10 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-16"x6" TEE
INSTALL:
161+20.00, 34.50' LT
34.5'CL McKINNEY STREET
CONNECT TO EX. 12" WATER (N)
5 LF 12" PVC WATER
2-16" GATE VALVES
1-16"x12" TEE
INSTALL:
REMOVE EX. 16"x12" TEE
159+35.68, 34.50' LT
CONNECT TO EX. 12" WATER (N)
4 LF 12" PVC WATER
1-16" GATE VALVE
1-16"x12" TEE
INSTALL:
REMOVE EX. 16"x12" TEE
159+65.68, 34.50' LT
1-16" GATE VALVE
10 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-16"x6" TEE
INSTALL:
158+00.00, 34.50' LT
STEEL ENCASEMENT PIPE
EX. 25 LF 24", 1/4"
585
580
575
590
595
600
570
585
580
575
590
595
600
570
16" DUCTILE IRON CLASS 52 WATER
INSTALL 450 LF
EX. 16" WATER TO BE KILLED
CLASS B-3 EMBEDMENT
450 LF 16" DUCTILE IRON AWWA CLASS 52
16" WATER LINE D
ALONG EX. R.O.W.
ON STEEL T POSTS ON 6' CENTERS
WITH 4"x4" OPENINGS
WELDED WIRE MESH FENCE
INSTALL 277 LF OF 60" TALL
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT24.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT24.dgn1:404:45:01 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
16" WATER LINE D
WATER PLAN & PROFILE
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
D
E McKINNEY STREET & TRINITY ROAD
THE WOODLANDS ON McKINNEY STREET LLC
E McKINNEY STREET
ATMOS ENERGY CORP
E McKINNEY STREET
ATMOS ENERGY CORP
LOT 143, 144
LOT 146LOT 147A
FM
16" W16" W
18" RCP 18" RCPD PC 164+36.86162+00 163+00 164+00 165+00 166+00
16" W 16" W 16" W 16" W
162+00 163+00 164+00 165+00 166+00FL 16" = 583.68 FL 16" = 584.58 FL 16" = 585.48 FL 16" = 586.38 FL 16" = 587.28 FL 16" = 589.08 FL 16" = 589.98 FL 16" = 590.18 FL 16" = 590.38 FL 6" = 588.60FL 16" = 588.18 1-16" GATE VALVE1-16"x6" TEEINSTALL:LINE D 164+00.00, 34.50' LT1-TYPE 1 AIR RELEASE VALVEINSTALL:LINE D 165.97.50, 35.17' LTAT PIPE CL
EX. GROUND
AT PIPE CL
PROP. GROUND
(+) 1.80%(+) 0.40%(+) 0.40%
WITH 6' OF COVER
1/4" STEEL ENCASEMENT PIPE
EX. 25 LF 24",PULL PIPE (DOWN)LINE D 165+00.00, 35.40' LTEX. GAS
EX. GAS
McKINNEY STREET
MATCHLINE STA 161+50274MATCHLINE STA 166+00MATCHLINE STA 166+00MATCHLINE STA 161+50ORR ROAD
F.L. XXXT.C. XXXCL 10' REC. INLETPAV STA 117+31.37, 39.50' RT
16" WATER LINE D
EX. R.O.W.
EX. R.O.W.
1-16" GATE VALVE
9 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-16"x6" TEE
INSTALL:
164+00.00, 34.50' LT
34.5'CL McKINNEY STREET
EX. R.O.W.
STEEL ENCASEMENT PIPE
EX. 25 LF 24", 1/4"
585
580
590
595
600
610
605
585
580
590
595
600
610
605
STANDARD DRAWING W801
PER CITY OF DENTON
1-TYPE I AIR RELEASE VALVE
INSTALL:
165+97.50, 35.17' LT
16" DUCTILE IRON CLASS 52 WATER
INSTALL 449 LF
EX. 16" WATER TO BE KILLED
CLASS B-3 EMBEDMENT
449 LF 16" DUCTILE IRON AWWA CLASS 52
16" WATER LINE D
ALONG EX. R.O.W.
ON STEEL T POSTS ON 6' CENTERS
WITH 4"x4" OPENINGS
WELDED WIRE MESH FENCE
INSTALL 449 LF OF 60" TALL
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT25.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT25.dgn1:404:45:03 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
16" WATER LINE D
WATER PLAN & PROFILE
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
594.11
5/8" IRS W/RANDOM
40
D
E McKINNEY STREET & TRINITY ROAD
THE WOODLANDS ON McKINNEY STREET LLC
LOT 145
E McKINNEY STREET
ATMOS ENERGY CORP
LOT 146
LOT 143, 144
TRINITY ROAD
E McKINNEY STREET &
McKINNEY STREET LLC
THE WOODLANDS ON
FM
16" W 16" W16" W 18" RCP18" RCP
D
EX. GAS
(EMPTY UNTIL FUTURE EXTENSION)
18" RCP PT 168+00.19166+00
167+00 168+00 169+00 170+00
16" W
16" W 16" W 16" W
166+00 167+00 168+00 169+00 170+00FL 16" = 590.38 FL 16" = 589.58 FL 16" = 587.98 FL 16" = 587.18 FL 16" = 586.38 FL 16" = 585.58 FL 16" = 584.88 FL 16" = 583.48 FL 6" = 589.20FL 16" = 588.78 FL 6" = 584.60FL 16" = 584.18 1-16" GATE VALVE1-16"x6" TEEINSTALL:LINE D 167+00.00, 33.50' LT1-16" GATE VALVE1-16"x6" TEEINSTALL:LINE D 170+00.00, 31.00' LTAT PIPE CL
EX. GROUND
AT PIPE CL
PROP. GROUND
(-) 1.60%
(-) 1.60%(-) 1.40%
WITH 6' OF COVER
1/4" STEEL ENCASEMENT PIPE
EX. 25 LF 24",PULL PIPE (UP)LINE D 169+00.00, 35.40' LTMcKINNEY STREET
MATCHLINE STA 166+00275MATCHLINE STA 170+50MATCHLINE STA 166+00MATCHLINE STA 170+50CV D-2
16" WATER LINE D
PT CV D-2
168+00.33 LINE D
1-16" GATE VALVE
6 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-16"x6" TEE
INSTALL:
170+00.00, 31.00' LT
31'EX. R.O.W.
EX. R.O.W.
CL McKINNEY STREET
1-16" GATE VALVE
8 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-16"x6" TEE
INSTALL:
167+00.00, 33.50' LT
DEG = 1° 02' 30.27"
CURVE 2 (CV D-2)
= 2° 39' 03.82" LT
T = 127.26'
L = 254.48'
R = 5,500.00'
PC STA = 166+37.66, 34.60' LT
PT STA = 168+93.06, 31.00' LT
N = 7124913.27
E = 2406948.65
PI STA = 167+65.65, 32.37' LT
PC CV D-2
166+37.66 LINE D
STEEL ENCASEMENT PIPE
EX. 25 LF 24", 1/4"
585
580
575
590
595
600
605
585
580
575
590
595
600
605
16" DUCTILE IRON CLASS 52 WATER
INSTALL 449 LF
EX. 16" WATER TO BE KILLED
CLASS B-3 EMBEDMENT
449 LF 16" DUCTILE IRON AWWA CLASS 52
16" WATER LINE D
ALONG EX. R.O.W.
ON STEEL T POSTS ON 6' CENTERS
WITH 4"x4" OPENINGS
WELDED WIRE MESH FENCE
INSTALL 449 LF OF 60" TALL
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT26.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-UWT26.dgn1:404:45:06 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
16" WATER LINE D
WATER PLAN & PROFILE
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
S
S
S
587.06
5/8" IRS W/RANDOM
41
D
E McKINNEY STREET
ATMOS ENERGY CORP
E McKINNEY STREET & TRINITY ROAD
THE WOODLANDS ON McKINNEY STREET LLC
LOT 146
LOT 143, 144
VOL. 695, PG. 351
16' UTILITY EASEMENT
VOL. XX, PG. XX
UTILITY EASEMENT
VARIABLE WIDTH
VOL. XX, PG. XX
25' UTILITY EASEMENT
VOL. XX, PG. XX
16' UTILITY EASEMENT
TRINITY ROAD
E McKINNEY STREET &
McKINNEY STREET LLC
THE WOODLANDS ON LOT 143, 144
GRISSOM ROAD
E McKINNEY STREET &
YES COMPANIES KEY LLC
VOL. XX, PG. XX
EASEMENT
30' TEMPORARY CONSTRUCTION
16" W 16" W 16" W
21" WW
21" WW21" WW18" RCPD
18" RCP
18" RCP
16" W
RCP18" FUTURE EXTENSION)
(EMPTY UNTIL
18" RCP
(EMPTY UNTIL FUTURE EXTENSION)
24" RCP
(EMPTY UNTIL FUTURE EXTENSION)
24" RCP
171+00 172+00 173+00 174+00 175+00
16" W
16" W 16" W
171+00 172+00 173+00FL 16" = 583.48 FL 16" = 582.78 FL 16" = 582.08 FL 16" = 581.38 FL 16" = 580.68 FL 16" = 579.28 FL 6" = 580.40FL 16" = 579.98 FL 16" = 579.17FL EX. 16" = 576.25FL 16" = 576.251-16" GATE VALVE1-16"x6" TEEINSTALL:LINE D 173+00.00, 40.00' LTEx. 16" Water
AT PIPE CL
EX. GROUND
AT PIPE CL
PROP. GROUND
4.00° LEFTPULL PIPELINE D 171+22.77, 31.00' LT4.00° RIGHTPULL PIPELINE D 172+51.48, 40.00' LTEND PROP. 16" WATER LINE DCONNECT TO EX. 16 WATER1-16" GATE VALVE1-16" 45° H. BENDINSTALL:LINE D 173+65.00, 32.96' LT1-16" 45° COMBO. BENDINSTALL:LINE D 173+57.96, 40.00' LT(-) 1.40%(-) 41.42
%EX. CCTV EX. GAS
EX. GAS
EX. CCTV
McKINNEY STREET
MATCHLINE STA 170+50276MATCHLINE STA 170+5016" WATER LINE D EX. R.O.W.40'EX. R.O.W.
1-16" GATE VALVE
9 LF 6" PVC WATER
1-FH ASSEMBLY
1-6" GATE VALVE
1-16"x6" TEE
INSTALL:
173+00.00, 40.00' LT
CL McKINNEY STREET31'4.00° RIGHT
PULL PIPE
172+51.48, 40.00' LT
4.00° LEFT
PULL PIPE
171+22.77, 31.00' LT
EX. R.O.W.
END PROP. 16" WATER LINE D
CONNECT TO EX. 16 WATER (SW)
1-16" GATE VALVE
1-16" 45° H. BEND
INSTALL:
173+65.00, 32.96' LT
1-16" 45°COMBO. BEND
INSTALL:
173+57.96, 40.00' LT
585
580
575
590
595
600
570
585
580
575
590
595
600
570
16" DUCTILE IRON CLASS 52 WATER
INSTALL 318 LF
EX. 16" WATER TO BE KILLED
CLASS B-3 EMBEDMENT
318 LF 16" DUCTILE IRON AWWA CLASS 52
16" WATER LINE D
EX. 16" WATER
CUT & PLUG
ALONG EX. R.O.W.
ON STEEL T POSTS ON 6' CENTERS
WITH 4"x4" OPENINGS
WELDED WIRE MESH FENCE
INSTALL 473 LF OF 60" TALL
LOT 143, 144
E McKINNEY STREET & TRINITY ROAD
THE WOODLANDS ON McKINNEY STREET LLC
TO EXISTING WIRE AND POST FENCE
CONNECT PROP. WELDED WIRE MESH FENCE
1"=40'H
1"=10'V CITY OF DENTON - McKINNEY STREET PHASE TWOMcKINNEY STREET - PHASE 2
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400
Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USS01.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-USS01.dgn1:40.01944:45:08 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
KENNETH A. ROBERTS
55446P
ROFES
SIONAL ENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
10" LINE A & 12" LINE B
WASTEWATER PLAN & PROFILECONCRETECONCRETESS12" W20" W
16" W20" W16" W20" W12" W12" W
8" W8" W8" WW8" WW
8" WWBOX CULVERT
10'x4'114+00115+00BOX CULVERT
5'x4'18" RCP18"18" RCP5'X2' RCBD16" W16" W10" WW
0+00 1+00
6" PVC SLEEVES
0+00 1+00 FL EX. 8" WW IN=572.74FL PROP. 10" WW OUT=572.54FL PROP. 10" WW IN=572.24FL EX. 8" WW OUT=572.04FL PROP. 10" WW=572.36FL PROP. 10" WW=572.49AT PIPE CL
EX. GROUND
PROP. 10" WW IN (N)EX. 8" WW OUT (W)CONNECT:1-STD. 4.0' DIA. WWMHCONSTRUCT:REMOVE EX. 4.0' DIA. WWMH0+00.00 PROP. 10" WW LINE AEX. 8" WW IN (E)PROP. 10" WW OUT (S)CONNECT:1-STD. 4.0' DIA. WWMHCONSTRUCT:REMOVE EX. 4.0' DIA. WWMH1+22.32 PROP. 10" WW LINE A10" ON 0.25%
AT PIPE CL
PROP. GROUND
(To Be Removed)
Ex. 8" WW
EX. FIBER
EX. GAS
FL 18" 578.93
PROP. 18" RCP
FL 16" 568.35
PROP. 16" WATER
FL 16" 574.95+/-
(T0 BE KILLED)
EX. 16" WATER
(TO BE KILLED)
EX. 8" WATER 150+00151+00CONCRETEESS582.48X CUT SET38WVFMFM16" W16" W8" WW12" WW
12" WW8" WW8" WW18" RCP8" WW16" W16" W6" PVC SLEEVES12" WW
0+00 1+00
18"24" RCP24" RCP24" RCP24" RCP18" RCP
PROP. 10" WW IN (N)EX. 8" WW OUT (W)CONNECT:1-STD. 4.0' DIA. WWMHCONSTRUCT:REMOVE EX. 4.0' DIA. WWMH0+00.00 PROP. 10" WW LINE AEX. 8" WW IN (SE)EX. 8" WW IN (NW)PROP. 12" WW OUT (SW)CONNECT:1-STD. 4.0' DIA. WWMHCONSTRUCT:REMOVE EX. 4.0' DIA. WWMH1+33.29 PROP. 12" WW LINE BEx. 12" WW
AT PIPE CL
PROP. GROUND
AT PIPE CL
EX. GROUND
12" ON 1.85%
EX. CCTV
EX. FOC
EX. GAS
(TO BE KILLED)
EX. 16" WATER
FL 16" 568.35
PROP. 16" WATER
FL 24" 577.68
PROP. 24" RCP FL 24" 577.97
PROP. 24" RCP
(To Be Removed)
w/ 20" Steel EncasementEx. 12" WW
0+00 1+00 FL EX. 8" WW IN(SE)=572.34FL EX. 8" WW IN(NW)=574.05FL PROP. 12" WW OUT=572.13FL PROP. 12" WW IN=569.70FL EX. 12" WW OUT=569.50FL PROP. 12" WW=570.59FL PROP. 12" WW=571.51277
LOT 151 (PT)
E McKINNEY STREET
CITY OF DENTON
LOT 153
4301 E McKINNEY STREET
CITY OF DENTON
LOT 154
MAYHILL ROAD
10" WW LINE A
BEGIN 10" WW LINE A
PROP. 10" WW IN (N)
EX. 8" WW OUT (W)
CONNECT:
1-STD. 4.0' DIA. WWMH
CONSTRUCT:
REMOVE EX. 4.0' DIA. WWMH
E: 2402208.15
N: 7127160.83
0+00.00 PROP. 10" WW LINE A
END 10" WW LINE A
EX. 8" WW IN (E)
PROP. 10" WW OUT (S)
CONNECT:
1-STD. 4.0' DIA. WWMH
CONSTRUCT:
REMOVE EX. 4.0' DIA. WWMH
E: 2402238.31
N: 7127279.38
1+22.32 PROP. 10" WW LINE A
570
585
580
575
590
565
595
570
585
580
575
590
565
595
CONSTRUCT 10" WASTEWATER LINE
IN SAME TRENCH AS EX. 8" WW
EX. R.O.W
EX. R.O.W
CL McKINNEY STREETCLASS B-3 EMBEDMENT
ASTM D3034 (SDR-35)
123 LF 10" PVC WASTEWATER PIPE
10" WASTEWATER LINE AMcKINNEY STREET1+06.500+06.50REFERENCE ONLY McKINNEY STREETS FORK DRIVE
LOT 1
LOT 147B
E McKINNEY STREET
ATMOS ENERGY CORP
(200' STRIP)
E McKINNEY STREET
VENTURES, LP
BCI REAL ESTATE
PG. 01970
VOL. 5039,
DRAINAGE EASEMENT
20' PERMANENT
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
LOT 1
24" RCP
CL McKINNEY STREET18" RCP18" RCP5'X2' RCB16" W16" W16" W16" W6" PVC SLEEVESCONSTRUCT 12" WASTEWATER LINE
IN SAME TRENCH AS EX. 12" WW
BEGIN 12" WW LINE B
PROP. 12" WW IN (NE)
EX. 12" WW OUT (SW)
CONNECT:
1-STD. 4.0' DIA. WWMH
CONSTRUCT:
REMOVE EX. 4.0' DIA. WWMH
E: 2405507.33
N: 7125809.39
0+00.00 PROP. 12" WW LINE B
END 12" WW LINE B
EX. 8" WW IN (SE)
EX. 8" WW IN (NW)
PROP. 12" WW OUT (SW)
CONNECT:
1-STD. 4.0' DIA. WWMH
CONSTRUCT:
REMOVE EX. 4.0' DIA. WWMH
E: 2405572.02
N: 7125925.94
1+33.29 PROP. 12" WW LINE B24" RCP24" RCP1+00
EX. R.O.W
EX. R.O.W
EX. R.O.W0+25.001+25.00 0+25.001+25.00
24" RCP
CLASS B-3 EMBEDMENT
ASTM D3034 (SDR-35)
133 LF 12" PVC WASTEWATER PIPE
12" WASTEWATER LINE B
(MINIMUM 18")
1/2" STEEL ENCASEMENT PIPE LIMITS
100 LF
(MINIMUM 18")
1/2" STEEL ENCASEMENT PIPE LIMITS
100 LF 0+06.501+06.50(MINIMUM 18")
1/2" STEEL ENCASEMENT PIPE LIMITS
18 LF
(MINIMUM 18")
1/2" STEEL ENCASEMENT PIPE LIMITS
100 LF
S LOOP 288
N LOOP 288
E. McKINNEY STEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUMA
T
C
H
L
I
N
E
:
S
H
E
E
T
279
E. McKINNEY STE. McKINNEY STEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUMATCHLINE: SHEET 278
MA
T
C
H
L
I
N
E
:
S
H
E
E
T
280
DU
C
H
E
S
S
D
R E. McKINNEY STEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUMATCHLINE: SHEET 279
MA
T
C
H
L
I
N
E
:
S
H
E
E
T
281
E. McKINNEY STEU
EU
EU
NEW 240/120, 1 PH, 3 W,ELECTRIC SERVICE ATEXISTING POLENEW LIGHTINGCONTACTOR PANELGROUND BOX, TYPICALGROUND BOX, TYPICALEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUMATCHLINE: SHEET 280
MAT
C
H
L
I
N
E
:
S
H
E
E
T
282
END WORK THISCONTRACT. WORKFROM STA 106+00 TO119+50 BY OTHERS
E. McKINNEY STEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUMATCHLINE: SHEET 281
MATCH
L
I
N
E
:
S
H
E
E
T
283 END WORK THISCONTRACT. WORKFROM STA 106+00 TO119+50 BY OTHERSREFERENCE ONLYWORK FROM STA 106+00TO 119+50 BY OTHERS
S MAYHILL RD N MAYHILL RDE. McKINNEY STEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUMATCHLINE: SHEET 282
MATCH
L
I
N
E
:
S
H
E
E
T
284 WORK FROM STA 106+00TO 119+50 BY OTHERSREFERENCE ONLY
PRIVATE RDE. McKINNEY STEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUMATCHLINE: SHEET 283
MATC
H
L
I
N
E
:
S
H
E
E
T
285 WORK FROM STA 106+00TO 119+50 BY OTHERSREFERENCE ONLY
E. McKINNEY STEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUMATCHLINE: SHEET 284
MATCHLIN
E
:
S
H
E
E
T
286 BEGIN WORK THISCONTRACT. WORKFROM STA 106+00 TO119+50 BY OTHERS
E. McKINNEY STEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUMATCHLINE: SHEET 285
MATCHLINE: SHEET 287
N CARPENTER RDE. McKINNEY STEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUMATCHLINE: SHEET 286
MATCHLINE: SHEET 288
E. McKINNEY STEU EU EU
NEW 240/120, 1 PH, 3 W,ELECTRIC SERVICE ATEXISTING POLENEW LIGHTINGCONTACTOR PANELGROUND BOX, TYPICALGROUND BOX, TYPICALEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUMATCHLINE: SHEET 287
MATCHLINE: SHEET 289
E. McKINNEY STEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUMATCHLINE: SHEET 288
MATCHLINE: SHEET 290
GLENNGARY WAYE. McKINNEY STE. McKINNEY STEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUMATCHLINE: SHEET 289
MATCHLINE: SHEET 291
E. McKINNEY STE. McKINNEY STEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUMATCHLINE: SHEET 290
MATCHLINE: SHEET 292
E. McKINNEY STE. McKINNEY STS FORKEUEUEUEUEUEUEUEUEU
EUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUMATCHLINE: SHEET 291
MATCHLINE: SHEET 293
E. McKINNEY STE. McKINNEY STEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUMATCHLINE: SHEET 292
MATCHLINE: S
H
E
E
T
294
E. McKINNEY STEU EU EU
NEW 240/120, 1 PH, 3 W,ELECTRIC SERVICE ATEXISTING POLENEW LIGHTINGCONTACTOR PANELGROUND BOX, TYPICALGROUND BOX, TYPICALEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUMATCHLINE: SHEET 293
MATCHLINE: SHEET 295
E. McKINNEY STE. McKINNEY STEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUMATCHLINE: SHEET 294
MATCHLINE: SHEET 296
E. McKINNEY STEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUMATCHLINE: SHEET 295
MATCHLINE: SHEET 297
E. McKINNEY STEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUEUMATCHLINE: SHEET 296
ALL CONDUIT SHALL BE 2" TYPE EPC-40-PVCNOTES:1.ROADWAY AND PEDESTRIAN POLES AND LUMINAIRES AREFURNISHED BY DENTON MUNICIPAL ELECTRIC FOR INSTALLATION BYTHE CONTRACTOR.*FOR REFERENCE ONLY
STREET LUMINAIRE POLE FOUNDATION DETAILSD1NOT TO SCALE
STREET LUMINAIRE CONDUIT AND GROUND BOX DETAILSD2NOT TO SCALE
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOLEGEND:
NOTES:
SIDEWALK
PROPOSED CONCRETE
McKINNEY STREET - PHASE 2
MINIMUM RADIUS = 60'
BIKE/PED PATH DESIGN SPEED = 18 MPH.2.
FOR ADDITIONAL INFORMATION.
1. SEE CITY OF DENTON STANDARD DETAILS
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CSW01.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CSW01.dgn1:404:45:13 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
SIDEWALK PLAN
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
PARKING AREA
S
S
S
587.72
5/8" IRS W/RANDOM
3
0LOT 24A
LOOP 288
7-ELEVEN INC
LOT 1
LOT 1
101 N LOOP 288
DENNIS J KOOP
LOT 1
3612 E McKINNEY STREET
McKINNEY BUILDING, LP
VOL. 1029, PG. 281
UTILITY EASEMENT
75' MAINTAINING PUBLIC
VOL. 60
3,
PG. 520
EASEMENT
16' PUBL
IC UT
IL
ITY
CAB. R, PG. 32
EASEMENT
20' PUBLIC UTILITY
CAB. F, PG. 336ELEC. EASEMENT20' UTILITY &
VOL. 603, PG. 520
EASEMENT16' PUBL
IC UT
IL
ITY
101 S LOOP 288
INVESTMENT COMPANY
SEJ ASSET MANAGEMENT &
CAB. F, PG. 336& ELEC.EASEMENT16' UTILITY
D.R.D.C.T.
PG. 394
VOL. 440,
EASEMENT
DRAINAGE
40' TXDOT
WV
WV WV
LT
LT
LT
LT
LT30" WW3
0
" WW3
0
" WW8" WW8" WW
8" W
8"
W8" W8" W2
0" W
20
" W
8" W
24" RCP
36" RCP
36" RCP
BOX CULVERTEx. 9'
x
5' BOX CULVERTEx.
9'
x
5' BOX CULVERTEx.
9'
x
5' BOX CULVERTEx. 5'x4' BOX CULVERTEx.
5'x4' BOX CULVERTEx.
5'
x
4' BOX CULVERTEx.
5'
x
3' BOX CULVERTEx.
6'
x
3'
24" RCP
24" RCP
24" RCP
24
" RC
PWV
2
0" W
PT 90+20.1888+00 90+00
91+00
87+00
1
0072+
0
0
100
7
3
+0
0
1
0
0
7
4
+0
0
89+00
24" RCP
4'X2' RCB
12" W
12" W
EX. R.O.W
301MATCHLINE STA 91+50N LOOP 28
8
S LOOP 28
8
EX. R.O.W
EX. R.O.W
EX. R.O.W
6' SIDEWALK
STREETCL McKINNEY LOOP 288
STA 10073+29.69
McKINNEY STREET=
STA 88+88.74
DENTON COUNTY, TX
MINUTES
COMMISIONER'S COURT
PAGE 366
ATTACHED TO VOL S,
DATED: 10-08-1947
RIGHT OF WAY EASEMENT 5.5'5.5'McKINNEY STREET
McKINNEY STREET
CONSTRUCTION
BIKE/PED PATH
BEGIN 12'
STA 89+41.97
EX. R.O.W
EX. R.O.W
STRIPE (TYP.)
THERMOPLASTIC
4" YELLOW
(TYP.)
3'
(TYP.)
9'
LOOP 288
7-ELEVEN INC
LOT 24A
PATH
12' BIKE/PED
ALTERNATE BID
CONSTRUCTION
BEGIN 6' SIDEWALK
STA 90+77.72
KEEP KEEP
RIGHT LEFT RIGHTLEFT
24x18
R9-7 (MOD)
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOLEGEND:
NOTES:
SIDEWALK
PROPOSED CONCRETE
McKINNEY STREET - PHASE 2
MINIMUM RADIUS = 60'
BIKE/PED PATH DESIGN SPEED = 18 MPH.2.
FOR ADDITIONAL INFORMATION.
1. SEE CITY OF DENTON STANDARD DETAILS
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CSW02.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CSW02.dgn1:404:45:15 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
SIDEWALK PLAN
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
V
E
PARKING AREA
S
PARKING AREA
VOL. 603, PG. 520
EASEMENT
16' PUBLIC UTILITY
CAB. R, PG. 32
EASEMENT
20' PUBLIC UTILITY CAB. D, PG. 191
16' UTILITY EASEMENT
3730 E McKINNEY STREET
LISA FONG LEUNG
100 N LOOP 288
100 NORTH LOOP 288, LLC
101 S LOOP 288
DNB INVESTMENTS LTD
101 S LOOP 288
SEJ ASSET MANAGEMENT & INVESTMENT COMPANY
LOOP 288
7-ELEVEN INC
LOT 1LOT 41LOT 1
LOT 24A
VOL. 603, PG. 520
EASEMENT
16' PUBLIC UTILITY
WV
WV
8" WW 8" WW 8" WW
8" W8" W 8" W
8" W
8" W
8" W 8" W 8" W
24" RCP
18" RCP
15" RCP
24" RCP 8" W
20" W
PT 94+85.56 PC 93+74.5992+00 93+00 94+00 95+00
96+00
D18" RCP 18" RCP 18" RCP 18"
24" RCP
D
4'X2' RCB RCP30" 24" RCP
18"
12" W 12" W 12" W
12" W
20" W
20" W
20" W
20" W6" PVC SLEEVES
6" PVC SLEEVES6" PVC SLEEVES6" W6" WCAB. D, PG. 191
16' UTILITY EASEMENT
CAB. O, PG. 264
EASEMENT
15' PUBLIC UTILITY
CAB. O, PG. 264
10' UTILITY EASEMENT
CAB. O, PG. 264
10' UTILITY EASEMENT
CAB. XX, PG. XX
EASEMENT
PRIVATE DRAINAGE
CAB. X, PG. XX
EASEMENT
8' PUBLIC UTILITY
CAB. D, PG. 15
20' PUBLIC UTILITY EASEMENT
E McKINNEY STREET
CCD-RLG DENTON I LP
3701 E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
3730 E McKINNEY STREET
LISA FONG LEUNG 191 DUCHESS DRIVE
JBJ/CALDER FUND VII JOINT VENTURE
LOT 1LOT 1
LOT 1
LOT 1
LOT 1
100 N LOOP 288
LLC
100 NORTH LOOP 288, PC 99+35.0897+00 98+00 99+00 100+00 101+00
V
15" HACKBERRY
S
S S
WV
WV
WV
8" WW
8" WW 8" WW
8" W 8" W 8" W 8" W
8" W
8" W 8" W 6" W(15" STEEL ENCASEMENT)8" WW(15" STEEL ENCASEMENT)8" WW8" W8
" W6" W
6" W6" W
T
20" W
12" W 12" W 12" W 12" W
20" W 20" W
20" W
6" W6" W6" PVC
SLEEVES
6" PVC SLEEVES
6" PVC SLEEVES6" W24" RCP
18" RCP
D18"
D
CL McKINNEY STREET
McKINNEY STREET MATCHLINE STA 96+50CV-3
DRIVEDUCHESS FENCEIRON
EX. WROUGHT
EX. R.O.W
EX. R.O.W
EX. R.O.W
6' SIDEWALK
6' SIDEWALK5.5'MATCHLINE STA 101+50MATCHLINE STA 96+50MATCHLINE STA 91+503'302
EX. R.O.W
6' SIDEWALK
CL McKINNEY STREET McKINNEY STREET
EX. R.O.W
5.5'120' R.O.W.120' R.O.W.(TYP.)
3'
(TYP.)
9'
(TYP.)
3'
(TYP.)
9'
STRIPE (TYP.)
THERMOPLASTIC
4" YELLOW
STRIPE (TYP.)
THERMOPLASTIC
4" YELLOW 5'5.5'12'BIKE/PED PATH
PATH
BIKE/PED
12' 3'ALTERNATE BID
ALTERNATE BID5.5'PC CV-1
STA 94+08.25, 37.00' LT
PCC CV-2
PCC CV-1
STA 94+70.83, 47.57' LT
PT CV-2
STA 95+38.37, 59.00' LT
PC CV-3
STA 96+11.14, 59.00' LT
DEG = 27° 48' 48.55"L = 64.47'R = 206.00'
R = 206.00'
L = 64.47'
T = 32.50'
DEG = 27° 48' 48.55"
= 17° 55' 57.87" LT
E = 2400367.97
N = 7127982.23
PI STA = 94+40.26, 39.71' LT
CURVE 1 (CV A-1)
100 N LOOP 288
100 NORTH LOOP 288, LLC
LOT 1
R = 206.00'
L = 69.03'
T = 34.84'
DEG = 27° 48' 48.55"
= 19° 11' 54.37" RT
E = 2400434.43
N = 7127971.36
PI STA = 95+04.34, 56.17' LT
CURVE 2 (CV A-2)
R = 206.00'
L = 67.63'
T = 34.12'
DEG = 27° 48' 48.55"
= 18° 48' 33.43" RT
E = 2400559.01
N = 7127903.77
PI STA = 96+45.11, 56.18' LT
CURVE 3 (CV A-3)
LOT 1
E McKINNEY STREET
CCD-RLG DENTON I LP
R = 206.00'
L = 67.63'
T = 34.12'
DEG = 27° 48' 48.55"
= 18° 48' 33.43" LT
E = 2400605.30
N = 7127583.63
PI STA = 97+10.63, 39.72' LT
CURVE 4 (CV A-4)
PT CV-4
STA 97+43.98, 37.00' LT
PCC CV-4
PCC CV-3
STA 96+77.57, 48.00' LT
5.5'PC CV-5
STA 100+31.39, 37.00' LT
R = 126.00'
L = 59.11'
T = 30.11'
DEG = 45° 28' 22.23"
= 26° 52' 40.20" LT
E = 2400914.45
N = 7127687.52
PI STA = 100+61.44, 40.49' LT
CURVE 5 (CV A-5)
PCC CV-6
PCC CV-5
50.30' LT
STA 100+88.90,
PATH
BIKE/PED
12'
R = 126.00'
L = 114.31'
T = 61.43'
DEG = 45° 28' 22.23"
= 51° 58' 44.95" RT
E = 2401005.98
N = 7127686.64
PI STA = 101+49.06, 62.90' LT
CURVE 6 (CV A-6)
KEEP KEEP
RIGHT LEFT RIGHTLEFT
24x18
R9-7 (MOD)
KEEP KEEP
RIGHT LEFT RIGHTLEFT
24x18
R9-7 (MOD)6" W
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOLEGEND:
NOTES:
SIDEWALK
PROPOSED CONCRETE
McKINNEY STREET - PHASE 2
MINIMUM RADIUS = 60'
BIKE/PED PATH DESIGN SPEED = 18 MPH.2.
FOR ADDITIONAL INFORMATION.
1. SEE CITY OF DENTON STANDARD DETAILS
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CSW03.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CSW03.dgn1:404:45:18 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
SIDEWALK PLAN
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
DBL. 10" HACKBERRY
18" ELM 6" TREE
TRI 4" TREE
QUAD 6" ELM
DBL. 8" HACKBERRY 6" ELM DBL. 6"/12" HACKBERRY DBL. 6" HACKBERRY DBL. 8" HACKBERRY
4" ELM
6" ELM
DBL. 12" HACKBERRY
DBL. 6" ELM
10" TREE
S
586.24
X CUT SET
32
CAB. D, PG. 15
20' PUBLIC UTILITY EASEMENT
CAB. O, PG. 264
10' UTILITY EASEMENT
CAB. O, PG. 264
10' UTILITY EASEMENT
CAB. B, PG. 71
25' UTILITY EASEMENT
CAB. B, PG. 7116' UTILITY EASEMENT
191 DUCHESS DRIVE
JBJ/CALDER FUND VII JOINT VENTURE
E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
STREET
3910 E McKINNEY SCOTTIE ADAMS
LOT 1
LOT 27 LOT 29
LOT 1
8" W
8" W
8" W
6" W
6" W
6" W6" W
6" W
8" WW PT 102+63.42 PC 104+55.99103+00 104+00 105+00
106+00
24" RCP18" RCP18" RCPD18"
RCP36" RCP18"
12" W
20" W 20" W 20" W 20" W
12" W 12" W
12" W
6" PVC SLEEVES6" W6" WCAB. B, PG. 71
25' UTILITY EASEMENTCAB. B, PG. 71
16' UTILITY EASEMENT
CAB. Y, PG. 289
20' UTILITY EASEMENT
3912 E McKINNEY STREET
DUNCAN STREET COMMERCIAL LLC3910 E McKINNEY STREET
SCOTTIE ADAMS
E McKINNEY STREET
McKINNEY MAYHILL PARTNERS LLC
3801 E McKINNEY STREET
ANGEL & GRISELDA ENRIQUEZ
3919/3921 E McKINNEY STREET
NSA PROPERTY HOLDINGS, LLC
3916 E McKINNEY STREET
EDWARD D & SHARYL K DIELEMAN
3918-3920 E McKINNEY STREET
LESLIE A & MICHAEL L ORINGDERFF
LOT 38
LOT 4
LOT 3LOT 2
LOT 1
LOT 29 LOT 1R
PT 107+79.73106+00
107+00 108+00 109+00 110+00
V
PARKING AREA PARKING AREA PARKING AREA PARKING AREA
PARKING AREA
24" HACKBERRYDBL. 12" TREE24" TREETRI 6" TREE
15" HACKBERRY10" CEDAR
DBL. 10" TREE
DBL. 12" HACKBERRY
S
WV
WVWV
WV
6" W
6" W
8" WW
8" WW 8" WW
8" W 8" W 8" W
6" W6" W
6" W
8" WW 8" WW
8" WW
20" W
12" W
12" W 12" W 12" W
20" W 20" W 20" W
12" W12" W6" PVC
SLEEVES 6" PVC
SLEEVES
6" PVC
SLEEVES 6" PVC
SLEEVES
6" PVC
SLEEVES
6" PVC SLEEVES
6" PVC SLEEVES
36" RCP 24"18"36" RCP
D 18"30" RCP24" RCP18"1
8"
R
C
P18"RCB
4'X4'
RCB
4'X4'
RCB
4'X4'
6' SIDEWALK
McKINNEY STREET
EX. R.O.W
MATCHLINE STA 101+50MATCHLINE STA 106+00EX. R.O.W FENCEIRON
EX. WROUGHT
FENCEIRON
EX. WROUGHT 5.5'5.5'EX. R.O.W
6' SIDEWALK
McKINNEY STREET
MATCHLINE STA 106+00MATCHLINE STA 110+50FENCE
EX. IRON
IRON FENCE
EX. WROUGHT
R.O.WEX. 5.5'5.5'303
R.O.WEX.
EX. R.O.W
CL McKINNEY STREET
113.5' R.O.W.103' R.O.W.120' R.O.W.120' R.O.W.(TYP.)
3'
(TYP.)
9'
STRIPE (TYP.)
THERMOPLASTIC
4" YELLOW
STRIPE (TYP.)
THERMOPLASTIC
4" YELLOW
(TYP.)
3'
(TYP.)
9'
2'ALTERNATE BID
DONE BY OTHERS TO STA 119+50
CONTRACT, BEGIN WORK TO BE
STA 106+00 END WORK THIS
ONLY
BID-REFERENCE
ALTERNATE
CV-6
PCC CV-7
PCC CV-6
STA 102+00.39, 49.63' LT
PT CV-7
STA 102+53.80, 37.00' LT
R = 114.00'
L = 54.98'
T = 28.04'
DEG = 50° 15' 34.04"
= 27° 38' 00.39" LT
E = 2401060.40
N = 7127615.64
PI STA = 102+26.89, 40.04' LT
CURVE 7 (CV A-7)
PC CV-8
STA 103+64.08, 37.00' LT
PATH
BIKE/PED
12'
PCC CV-9
PCC CV-8
STA 104+18.88, 49.55' LT
PT CV-9
STA 104+73.03, 62.00' LT
PC CV-10
STA 105+24.80, 62.00' LT
PCC CV-10
PCC CV-9
STA 105+77.33, 50.44' LT
R = 126.00'
L = 56.71'
T = 28.84'
DEG = 45° 28' 22.23"
= 25° 47' 09.95" LT
E = 2401211.96
N = 7127545.29
PI STA = 103+92.67, 40.29' LT
CURVE 8 (CV A-8)
R = 126.00'
L = 55.39'
T = 28.15'
DEG = 45° 28' 22.23"
= 25° 11' 22.83" RT
E = 2401268.94
N = 7127546.17
PI STA = 104+45.38, 58.87' LT
CURVE 9 (CV A-9)
CV-11
R = 126.00'
L = 52.40'
T = 26.58'
DEG = 45° 28' 22.23"
= 23° 49' 39.67" RT
E = 2401364.88
N = 7127504.64
PI STA = 105+52.17, 58.99' LT
CURVE 10 (CV A-10)
PATH
BIKE/PED
12'
R = 126.00'
L = 61.11'
T = 31.17'
DEG = 45° 28' 22.23"
= 27° 47' 20.31" LT
E = 2401404.76
N = 7127462.87
PI STA = 106+07.55, 40.27 LT
CURVE 11 (CV A-11)
PT CV-11
STA 106+37.96, 58.99' LT3.5'STREET
CL McKINNEY
KEEP KEEP
RIGHT LEFT RIGHTLEFT
24x18
R9-7 (MOD)
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOLEGEND:
NOTES:
SIDEWALK
PROPOSED CONCRETE
McKINNEY STREET - PHASE 2
MINIMUM RADIUS = 60'
BIKE/PED PATH DESIGN SPEED = 18 MPH.2.
FOR ADDITIONAL INFORMATION.
1. SEE CITY OF DENTON STANDARD DETAILS
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CSW04.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CSW04.dgn1:404:45:20 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
SIDEWALK PLAN
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
E
E
PARKING AREA
S
S
S
S
S
STREET
4001 E McKINNEY
CITY OF DENTON
E McKINNEY STREET
CITY OF DENTON
3922 E McKINNEY STREET
GOEL VENTURES ONE, LLC
3918-3920 E McKINNEY STREET
LESLIE A & MICHAEL L ORINGDERFF
3923 E McKINNEY STREET
DENTON 3919 McKINNEY, LLC
LOT 153
LOT 3
LOT 151 (PT)LOT 5R1
LOT 152
CAB. B, PG. 71
25' UTILITY EASEMENT
CAB. Y, PG. 289
20' UTILITY EASEMENT
CAB. B, PG. 147
16' UTILITY EASEMENT
VOL. 5039, PG. 01970
DRAINAGE EASEMENT
20' PERMANENT
STRIP)
E McKINNEY STREET (200'
VENTURES, LP
BCI REAL ESTATE
WV
wv1719590.20
WV
wv no lid5248583.02
Ex. 8" Water
Ex. 8" Water
Ex. 8" Wat
er
Ex. 16" Water
8" WW
8" W
6" W
12" W
12" W12" W6" W 12" W 12" W 20" W16" W
20" W20"
W20" W
8" WW 10" WW8" WW8" WW10" WW8" W20" W 12" W
12" W8" W
8" W
8" WW 8" WW8" WW
2-18" RCP
27" RCP
BOX CULVERT6'x4'BOX CULVERT6'x4'BOX CULVERT6'x4'B
O
X
C
U
L
V
E
R
T
6'x4'
8" WW
(ABANDONED)10" WW(AB
A
NDON
E
D)
1
0" WW8" WW
10'x4' RCBC PT 112+56.89 PC 111+52.17111+00 112+00 113+00 114+00 115+00
222+00223+00BOX CULVERT5'x4'18" RCP18"18" RCPD18"BOX CULVERT6'x4'BOX CULVERT6'x4'RCP24" RCP24" D
4'X4' RCBRCB
4'X4'
PARKING AREA
E McKINNEY STREET (200' STRIP)
BCI REAL ESTATE VENTURES, LP BAYLOR UNIVERSITY
4301 E McKINNEY STREET
CITY OF DENTON
4393 E McKINNEY STREET
KENNETH L & GLADYS F STOUT
LOT 151 (PT)LOT 151 (PT)
LOT 161LOT 154
STREET
4515 E McKINNEY
GLADYS F STOUT
KENNETH L &
STREET
4515 E McKINNEY
GLADYS F STOUT
KENNETH L &
WV16" W 16" W 16" W
8" W 8" W
8" WW 8" WW
15" CMP 15" CMP
PC 116+81.83116+00 117+00 118+00 119+0018"5'X2' RCB5'X2' RCB 5'X2' RCB
18" RCP20" W12" W
12" W16" W 16" W10" WW20" W
6" PVC SLEEVES 6" PVC SLEEVES
6" PVC SLEEVES
6" PVC SLEEVES6" WPC 13+00.5216" W 16" W 16" W
6" PVC SLEEVES
304MATCHLINE STA 110+50MATCHLINE STA 115+50MATCHLINE STA 115+50LOT 5R1
MATCHLINE STA 119+00BAYLOR UNIVERSITY
LOT 151 (PT)
EX. R.O.W
6' SIDEWALK
CL McKINNEY STREET
LINK FENCE
EX. CHAIN
EX. R.O.W
EX. R.O.W
6' SIDEWALK5.5'5.5'5' SIDEWALK
10' SIDEWALK
10' SIDEWALK
STA 222+65.23 MAYHILL ROAD
STA 112+75.57 McKINNEY STREET
PATH
12' BIKE/PED
5' SIDEWALK
5.5'5.5'S MAYHI
LL ROADMcKINNEY STREET N MAYHI
LL ROADMcKINNEY STREET
EX. R.O.W
PATH
12' BIKE/PED
EX. R.O.W
6' SIDEWALK
CL McKINNEY STREET
McKINNEY STREET
5.5'5.5'EX. R.O.W
EX. R.O.W
140' R.O.W.121' R.O.W.125' R.O.W.(TYP.)
3'
(TYP.)
9'
STRIPE (TYP.)
THERMOPLASTIC
4" YELLOW
(TYP.)
3'
(TYP.)
9'
STRIPE (TYP.)
THERMOPLASTIC
4" YELLOW
PATH
12' BIKE/PED
STRIPE (TYP.)
THERMOPLASTIC
4" YELLOW
ONLY
BID-REFERENCE
ALTERNATE
ONLY
BID-REFERENCE
ALTERNATE
R.O.W
EX.
KEEP KEEP
RIGHT LEFT RIGHTLEFT
24x18
R9-7 (MOD)
KEEP KEEP
RIGHT LEFT RIGHTLEFT
24x18
R9-7 (MOD)
KEEP KEEP
RIGHT LEFT RIGHTLEFT
24x18
R9-7 (MOD)
KEEP KEEP
RIGHT LEFT RIGHTLEFT
24x18
R9-7 (MOD)
STREET
4515 E McKINNEY
GLADYS F STOUT
KENNETH L &
LOT 161
4393 E McKINNEY STREET
KENNETH L & GLADYS F STOUT
LOT 159
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOLEGEND:
NOTES:
SIDEWALK
PROPOSED CONCRETE
McKINNEY STREET - PHASE 2
MINIMUM RADIUS = 60'
BIKE/PED PATH DESIGN SPEED = 18 MPH.2.
FOR ADDITIONAL INFORMATION.
1. SEE CITY OF DENTON STANDARD DETAILS
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CSW05.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CSW05.dgn1:404:45:23 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
SIDEWALK PLAN
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
PARKING AREA
PBX
585.19
5/8" IRS W/RANDOM
34
DOC # 99-R0026679
EASEMENT
20' PUBLIC UTILITY
BAYLOR UNIVERSITY
4515 E McKINNEY STREET
KENNETH L & GLADYS F STOUT
LOT 151 (PT)
LOT 161 LOT 162, 163, 164 (OLD DCAD 1P, 1P2, 1R), AC
4663 E McKINNEY STREET
MEMORIAL BAPTIST CHURCH OF DENTON
FM
16" W
16" W
8" W
8" WW 8" WW
15" CMP 15" CMP
16" W
119+00 120+00 121+00
5'X2' RCB
24" RCP 24" RCP
5'X2' RCB18"
16" W 16" W
6" PVC
SLEEVES
6" PVC SLEEVES
VOL. 5039, PG. 01056
EASEMENT
8' PUBLIC UTILITY
VOL. 5039, PG. 01056
EASEMENTCONSTRUCTION
20' TEMPORARY
VOL. 5039, PG. 01056
EASEMENT
20' PUBLIC UTILITY
BAYLOR UNIVERSITY
4663 E McKINNEY STREETMEMORIAL BAPTIST CHURCH OF DENTON 4673 E McKINNEY STREET
MEMORIAL BAPTIST CHURCH OF DENTON
4683 E McKINNEY STREET
SAYR RESOURCES INC
LOT 151 (PT)
LOT 162, 163, 164 (OLD DCAD 1P, 1P2, 1R), AC
LOT 166 LOT 167
BCI REAL ESTATE VENTURES,LP
LOT 151 (PT) PT 125+28.65122+00 123+00 124+00 125+00 126+00
PARKING AREA
DBL. 15"/24" PECAN24" PECAN
27" PECANDBL. 18" ELM
15" PECAN
TRI 12" PECAN
30" PECAN
DBL. 8" TREEDBL. 8"/15" TREE
S
WV
WV 16" W 16" W
8" W 8" W
8" WW 8" WW 8" WW
18" CMP 15" RCP 15" RCP
16" W16" W 16" W 16" W
6" PVC SLEEVES
6" PVC SLEEVES5'X2' RCB 36" RCPRCB
5'X3'MATCHLINE STA 121+50
F.L. XXXT.C. XXXCL 10' REC. INLETPAV STA 113+99.92, 39.49' RT
305MATCHLINE STA 121+50MATCHLINE STA 126+00MATCHLINE STA 119+00EX. R.O.W
5.5'5.5'EX. R.O.W
McKINNEY STREET
CL McKINNEY STREET
6' SIDEWALK
PATH
12' BIKE/PED
6' SIDEWALK
EX. R.O.W
EX. R.O.W
CL McKINNEY STREET
McKINNEY STREET5.5'5.5'EX. R.O.W
EX. R.O.W
EX. R.O.W121' R.O.W.111' R.O.W.111' R.O.W.121' R.O.W.127' R.O.W.(TYP.)
3'
(TYP.)
9'
STRIPE (TYP.)
THERMOPLASTIC
4" YELLOW
(TYP.)
3'
(TYP.)
9'
STRIPE (TYP.)
THERMOPLASTIC
4" YELLOW
PATH
12' BIKE/PED ALTERNATE BID
ALTERNATE BID
END WORK TO BE DONE BY OTHERS
BEGIN WORK THIS CONTRACT
STA 119+50
KEEP KEEP
RIGHT LEFT RIGHTLEFT
24x18
R9-7 (MOD)
KEEP KEEP
RIGHT LEFT RIGHTLEFT
24x18
R9-7 (MOD)
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOLEGEND:
NOTES:
SIDEWALK
PROPOSED CONCRETE
McKINNEY STREET - PHASE 2
MINIMUM RADIUS = 60'
BIKE/PED PATH DESIGN SPEED = 18 MPH.2.
FOR ADDITIONAL INFORMATION.
1. SEE CITY OF DENTON STANDARD DETAILS
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CSW06.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CSW06.dgn1:404:45:26 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
SIDEWALK PLAN
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
36" PECAN
36" PECAN
48" PECAN
6" HACKBERRY
21" CEDARDBL. 15"/24" PECAN
S
586.97
5/8" IRS W/RANDOM
35
BCI REAL ESTATE VENTURES,LP
5001 E McKINNEY STREET
BARBARA McDONALD COBB
5043 E McKINNEY STREET
CHELA DARLINE McDONALD
LOT 151 (PT)
LOT 168 LOT 169
VOL. 5039, PG. 01056
EASEMENTCONSTRUCTION
20' TEMPORARY
VOL. 5039, PG. 01056
EASEMENT
20' PUBLIC UTILITY
VOL. 5039, PG. 01056
EASEMENT
8' PUBLIC UTILITY DOC
#
9
9
-R0
07730
9UTILITY EASEMENT
2
0' PUBLI
C PC 129+61.61126+00 127+00 128+00 129+00 130+00
D
18" RCP18" RCP36"
R
CP
18" RCP
36" RCP
36" RCP18"18" RCPD
36" RCP
RCP
24"
4'x3' RCB
BCI REAL ESTATE VENTURES,LP
5101 E McKINNEY STREET
DENTON ISD
5090 E McKINNEY STREET
EDIBERTO A RODRIGUEZ E McKINNEY STREET
KIM Y PHAM
LOT 151 (PT)
LOT 1R4
LOT 150 LOT 1
CAB. H, PG. 62
20' UTILITY EASEMENT
CAB. E, PG. 330
4' SIDEWALK EASEMENT
130+00 131+00 132+00 133+00 134+00
135+00
BOX CULVERT3-6'x3'D
18"
30" RCP 24" RCP18"18" RCP36" RCP36" RCP36" RCP24" RCP24"24"18"RCB5'X3'
18" RCP
4'X3' RCB
4'X3' RCB
FM
16" W 16" W
8" WW 8"
WW6" W 6
" W8" W
8" WW 8"
WWWV
WV
WVFM
16" W 16" W
16" W
8" W
8" W 8" W 10" W
10" W
16" W 16" W 16" W 16" W 16" W
6" PVC
SLEEVES
6" PVC
SLEEVES
6" PVC
SLEEVES
6" PVC
SLEEVES
6" PVC
SLEEVES
16" W 16" W 16" W
16" W
1
0
" W6" PVC SLEEVES
6" PVC SLEEVES MATCHLINE STA 130+00MATCHLINE STA 130+00MATCHLINE STA 135+00MATCHLINE STA 126+00McKINNEY STREET
McKINNEY STREETRYAN WAY306ROADN CARPENTER5.5'5.5'R.O.WEX.
PATH
12' BIKE/PED
CL McKINNEY STREET
EX. R.O.W
6' SIDEWALK
R.O.WEX. 5.5'5.5'EX. R.O.W
R.O.WEX.
EX. R.O.W
6' SIDEWALK
EX. R.O.W
CL McKINNEY STREET
FENCE
EX. WOOD
(TYP.)
3'
(TYP.)
9'
STRIPE (TYP.)
THERMOPLASTIC
4" YELLOW
(TYP.)
3'
(TYP.)
9'
STRIPE (TYP.)
THERMOPLASTIC
4" YELLOW
5101 E McKINNEY STREET
DENTON ISD
LOT 1R4127' R.O.W.119' R.O.W.124' R.O.W.121.5' R.O.W.119' R.O.W.7'BID
ALTERNATE
BID
ALTERNATE
PC CV-12
STA 132+35.27, 37.00' LT
PCC CV-13
PCC CV-12
STA 132+85.59, 45.53' LT
R = 206.00'
L = 54.62'
T = 27.47'
DEG = 27° 48' 48.55"
= 15° 11' 30.34" RT
E = 2404005.12
N = 7126713.06
PI STA = 133+12.33, 48.77' LT
CURVE 13 (CV A-13)
PATH
BIKE/PED
12'
PT CV-13
STA 133+39.20, 50.50' LT
PC CV-14
STA 134+01.50, 50.50' LT
R = 206.00'
L = 54.62'
T = 27.47'
DEG = 27° 48' 48.55"
= 15° 11' 30.34" RT
E = 2404114.13
N = 7126668.55
PI STA = 134+28.68, 48.73' LT
CURVE 14 (CV A-14)
R = 206.00'
L = 54.62'
T = 27.47'
DEG = 27° 48' 48.55"
= 15° 11' 30.34" RT
E = 2404114.13
N = 7126668.55
PI STA = 134+80.19, 38.62' LT
CURVE 15 (CV A-15)
R = 206.00'
L = 51.19'
T = 25.73'
DEG = 27° 48' 48.55"
= 14° 14' 20.44" LT
E = 2403952.29
N = 7126719.30
PI STA = 132+60.77, 38.66' LT
CURVE 12 (CV A-12)PCC CV-15
PCC CV-14
43.53' LT
STA 134+55.11,
KEEP KEEP
RIGHT LEFT RIGHTLEFT
24x18
R9-7 (MOD)
KEEP KEEP
RIGHT LEFT RIGHTLEFT
24x18
R9-7 (MOD)
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOLEGEND:
NOTES:
SIDEWALK
PROPOSED CONCRETE
McKINNEY STREET - PHASE 2
MINIMUM RADIUS = 60'
BIKE/PED PATH DESIGN SPEED = 18 MPH.2.
FOR ADDITIONAL INFORMATION.
1. SEE CITY OF DENTON STANDARD DETAILS
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CSW07.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CSW07.dgn1:404:45:29 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
SIDEWALK PLAN
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
587.025/8" IRS W/RANDOM36
5101 E McKINNEY STREET
DENTON ISD
LOT 1R4
E McKINNEY STREET
KIM Y PHAM
LOT 1
CAB. H, PG. 6220' UTILITY EASEMENT
CAB. E, PG. 330
4' SIDEWALK EASEMENT
135+00 136+00 137+00 138+00
139+00
18" RCP
24" RCP
18" RCP
5101 E McKINNEY STREET
DENTON ISD
E McKINNEY STREET
KIM Y PHAM E McKINNEY STREET
KIM Y PHAM
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
LOT 1R4
LOT 1
LOT 1, BLOCK A
LOT 1, BLOCK B
CAB. H, PG. 62
20' UTILITY EASEMENT
CAB. H, PG. 62
16' UTILITY EASEMENT
CAB. E, PG. 60
16' UTILITY EASEMENTCAB.
H,
P
G.
6
2
1
6' UTI
LI
T
Y
E
AS
E
ME
N
T
CAB. E, PG. 330
EASEMENT
4' SIDEWALK
CAB. E, PG. 330
4' SIDEWALK EASEMENT PT 140+30.62139+00 140+00 141+00 142+00 143+00
V
E
ES
D18"24" RCP
18"RCP
WV
10" W 10" W
16" W
16" W
16" W
WV WV
WVWV
WV
WV
WVWV
FM
10" W 10" W
16" W 16" W 16" W 16" W16" W8" W10" WW
10" WW10"WW16" W
(F
O
R
C
E MAI
N)
8" WW8" WW8" W16" W 16" W 16" W
6" PVC SLEEVES
16" W 16" W 16" W 16" W16" W16" W16" W 16" W
16" W
6" PVC SLEEVES
6" PVC
SLEEVES
6" PVC SLEEVESMATCHLINE STA 143+50MATCHLINE STA 139+00MATCHLINE STA 135+00MATCHLINE STA 139+00McKINNEY STREET
McKINNEY STREET
GLENNGARY WAY307
PATH
12' BIKE/PED
R.O.WEX.
6' SIDEWALK
6' SIDEWALK
EX. R.O.W5.5'5.5'CL McKINNEY STREET
R.O.WEX.
6' SIDEWALK5.5'5.5'108' R.O.W.CL McKINNEY STREET
R.O.WEX.
PATH
12' BIKE/PED
5' SIDEWALK
R.O.WEX.
FENCE
EX. WOOD
FENCE
EX. WOOD
R.O.WEX.
STRIPE (TYP.)
THERMOPLASTIC
4" YELLOW
(TYP.)
3'
(TYP.)
9'
(TYP.)
3'
(TYP.)
9'
STRIPE (TYP.)
THERMOPLASTIC
4" YELLOW
BID
ALTERNATE
BID
ALTERNATE
PC CV-15
STA 135+05.42, 37.00' LT
CAB. H, PG. 62
16' UTILITY EASEMENT
KEEP KEEP
RIGHT LEFT RIGHTLEFT
24x18
R9-7 (MOD)
KEEP KEEP
RIGHT LEFT RIGHTLEFT
24x18
R9-7 (MOD)
5101 E McKINNEY STREET
DENTON ISD
LOT 1R4
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOLEGEND:
NOTES:
SIDEWALK
PROPOSED CONCRETE
McKINNEY STREET - PHASE 2
MINIMUM RADIUS = 60'
BIKE/PED PATH DESIGN SPEED = 18 MPH.2.
FOR ADDITIONAL INFORMATION.
1. SEE CITY OF DENTON STANDARD DETAILS
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CSW08.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CSW08.dgn1:404:45:31 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
SIDEWALK PLAN
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
S
E McKINNEY STREET
KIM Y PHAM
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
E McKINNEY STREET
ATMOS ENERGY CORP
LOT 1
LOT 147BLOT 1, BLOCK B
CAB. E, PG. 60
16' UTILITY EASEMENT
CAB. E, PG. 330
EASEMENT
4' SIDEWALK
144+00 145+00 146+00 147+00 148+00
D18"RCP18"18" RCP
E McKINNEY STREET
ATMOS ENERGY CORP
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
LOT 147B
LOT 1 LOT 1
CAB. E, PG. 60
16' UTILITY EASEMENT
CAB. E, PG. 60
16' UTILITY EASEMENT
PC 152+46.66148+00 149+00 150+00 151+00 152+00
CONCRETE E
S S
S
18" RCP 18" RCP
18"24" RCP 24" RCP 18" RCP24" RCP24" RCP18" RCPCULVERTBOX 3-7'x3'FM
T
16" W 16" W 16" W
8" WW 8" WW 8" WW 8" WW6" WW16" W 16" W 16" W
8" WW 8" WW 8" WW 8" WW6" WWWV
WV
FMFM
16" W
16" W
8" WW 8" WW
12" WW12" W W8" WW 8" WW
16" W
8" WW 6" WW8" WW
16" W 16" W 16" W 16" W
6" PVC
SLEEVES
16" W 16" W 16" W
16" W
6" PVC SLEEVES
12" WWMATCHLINE STA 143+50MATCHLINE STA 148+00MATCHLINE STA 152+50MATCHLINE STA 148+00McKINNEY STREET
McKINNEY STREETS FORK DRIVE308
12" WWFENCE
EX. WOOD
LINK FENCE
EX. CHAIN EX. R.O.W
6' SIDEWALK
CL McKINNEY STREET
R.O.WEX.
PATH
12' BIKE/PED 111' R.O.W.5.5'5.5'POND
EX. DETENTION
R.O.WEX.
6' SIDEWALK
EX. WOOD FENCE
FENCE
EX. WOOD
POND
EX. DETENTION
R.O.WEX.
PATH
12' BIKE/PED
EX. BRICK WALL
CL McKINNEY STREET
R.O.WEX.
EX. WOOD FENCE
5.5'5.5'111' R.O.W.108' R.O.W.(TYP.)
3'
(TYP.)
9'
STRIPE (TYP.)
THERMOPLASTIC
4" YELLOW
(TYP.)
3'
(TYP.)
9'
STRIPE (TYP.)
THERMOPLASTIC
4" YELLOW 5.5'BID
ALTERNATE
BID
ALTERNATE
KEEP KEEP
RIGHT LEFT RIGHTLEFT
24x18
R9-7 (MOD)
KEEP KEEP
RIGHT LEFT RIGHTLEFT
24x18
R9-7 (MOD)
KEEP KEEP
RIGHT LEFT RIGHTLEFT
24x18
R9-7 (MOD)
KEEP KEEP
RIGHT LEFT RIGHTLEFT
24x18
R9-7 (MOD)
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOLEGEND:
NOTES:
SIDEWALK
PROPOSED CONCRETE
McKINNEY STREET - PHASE 2
MINIMUM RADIUS = 60'
BIKE/PED PATH DESIGN SPEED = 18 MPH.2.
FOR ADDITIONAL INFORMATION.
1. SEE CITY OF DENTON STANDARD DETAILS
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CSW09.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CSW09.dgn1:404:45:33 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
SIDEWALK PLAN
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
S
E McKINNEY STREET
ATMOS ENERGY CORP
LOT 147A
E McKINNEY STREET
ATMOS ENERGY CORP
LOT 147B
LOT 1
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
CAB. E, PG. 60
16' UTILITY EASEMENT
PC 152+46.66 PT 156+32.66153+00
154+00 155+00 156+00
157+00
18" RCP3'x2' RCB
18" RCP
18"
E McKINNEY STREET
ATMOS ENERGY CORP
E McKINNEY STREET & TRINITY ROAD
THE WOODLANDS ON McKINNEY STREET LLC
K
O
R
N
U
P
A
U
L
& WE
N TS
AI
LOT 147A
LOT 143, 144L
O
T 108
LOT 1
5301 E McKINNEY STREET
YES COMPANIES KEY LLC
CAB. E, PG. 60
16' UTILITY EASEMENT
V
OL. 990, P
G.640
15'
UTILIT
Y E
AS
E
ME
N
T
157+00 158+00 159+00 160+00 161+00
585.97PK NAIL SET39
DD
FM
8" WW
16" W
16" W
8" WW
8" WW
16" W
16" W
8" WW
8" WW
8" WW
3'x2' RCB
3'x2' RCB
16" W 16" W 16" W12" W12" W8" WW
16" W 16" W 16" W12" W12" W8" WW
24" RCP 24" RCP 18"18" RCP18"18" RCP24" RCP
D RCP18" D
16" W
16" W
16" W
16" W
16" W 16" W 16" W 16" WMATCHLINE STA 152+50MATCHLINE STA 157+00MATCHLINE STA 161+50MATCHLINE STA 157+00McKINNEY STREET
McKINNEY STREET
309
POND
EX. DETENTION
EX. WOOD FENCEPATH
12' BIKE/PED
CL McKINNEY STREET
R.O.WEX.
6' SIDEWALK
FENCE
EX. CHAIN LINK 5.5'5.5'111' R.O.W.R.O.WEX.
R.O.WEX.
R.O.WEX. LINK FENCE
EX. CHAIN
6' SIDEWALK115' R.O.W.5.5'5.5'PATH
12' BIKE/PED
CL McKINNEY STREET
R.O.WEX.
FENCE
EX. WOOD 115' R.O.W.STRIPE (TYP.)
THERMOPLASTIC
4" YELLOW
(TYP.)
3'
(TYP.)
9'
3'(TYP.)
3'
(TYP.)
9'
STRIPE (TYP.)
THERMOPLASTIC
4" YELLOW
BID
ALTERNATE
BID
ALTERNATE
KEEP KEEP
RIGHT LEFT RIGHTLEFT
24x18
R9-7 (MOD)
KEEP KEEP
RIGHT LEFT RIGHTLEFT
24x18
R9-7 (MOD)
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOLEGEND:
NOTES:
SIDEWALK
PROPOSED CONCRETE
McKINNEY STREET - PHASE 2
MINIMUM RADIUS = 60'
BIKE/PED PATH DESIGN SPEED = 18 MPH.2.
FOR ADDITIONAL INFORMATION.
1. SEE CITY OF DENTON STANDARD DETAILS
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CSW10.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CSW10.dgn1:404:45:36 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
SIDEWALK PLAN
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
D
E McKINNEY STREET & TRINITY ROAD
THE WOODLANDS ON McKINNEY STREET LLC
E McKINNEY STREET
ATMOS ENERGY CORP
LOT 143, 144
LOT 147A LOT 146
E McKINNEY STREET
ATMOS ENERGY CORP PC 164+36.86162+00 163+00 164+00 165+00 166+00
E McKINNEY STREET & TRINITY ROAD
THE WOODLANDS ON McKINNEY STREET LLC
E McKINNEY STREET
ATMOS ENERGY CORP
LOT 146
LOT 145
LOT 143, 144
TRINITY ROAD
E McKINNEY STREET &
McKINNEY STREET LLC
THE WOODLANDS ON PT 168+00.19166+00 167+00 168+00 169+00 170+00
594.11
5/8" IRS W/RANDOM
40
D
FM
16" W16" W 16" W16" W
18" RCP 18" RCPD
FM
16" W 16" W16" W16" W 16" W16" W 18" RCP18" RCP
D
EX. GAS
(EMPTY UNTIL FUTURE EXTENSION)
18" RCP
16" W 16" W 16" W 16" W
16" W
16" W 16" W 16" WMATCHLINE STA 161+50MATCHLINE STA 166+00MATCHLINE STA 170+50MATCHLINE STA 166+00McKINNEY STREET
McKINNEY STREET
310ORR ROADEX. R.O.W
6' SIDEWALK
LINK FENCE
EX. CHAIN EX. R.O.W
LINK FENCE
EX. CHAIN
6' SIDEWALK
PATH
12' BIKE/PED
R.O.WEX.
CL McKINNEY STREET
115' R.O.W.5.5'5.5'EX. R.O.WLINK FENCE
EX. CHAIN
6' SIDEWALK
PATH
12' BIKE/PED
R.O.WEX.
CL McKINNEY STREET5.5'5.5'(TYP.)
3'
(TYP.)
9'
STRIPE (TYP.)
THERMOPLASTIC
4" YELLOW
(TYP.)
3'
(TYP.)
9'
STRIPE (TYP.)
THERMOPLASTIC
4" YELLOW
E McKINNEY STREET & TRINITY ROAD
THE WOODLANDS ON McKINNEY STREET LLC
LOT 145
112' R.O.W.BID
ALTERNATE
BID
ALTERNATE
PATH CONSTRUCTION
END 12' BIKE/PED
STA 169+43.58
KEEP KEEP
RIGHT LEFT RIGHTLEFT
24x18
R9-7 (MOD)
KEEP KEEP
RIGHT LEFT RIGHTLEFT
24x18
R9-7 (MOD)
KEEP KEEP
RIGHT LEFT RIGHTLEFT
24x18
R9-7 (MOD)
KEEP KEEP
RIGHT LEFT RIGHTLEFT
24x18
R9-7 (MOD)
(INCLUDE ON BASE BID)
TYPE 1A RAMP
CITY OF DENTON
1:40
CITY OF DENTON - McKINNEY STREET PHASE TWOLEGEND:
NOTES:
SIDEWALK
PROPOSED CONCRETE
McKINNEY STREET - PHASE 2
MINIMUM RADIUS = 60'
BIKE/PED PATH DESIGN SPEED = 18 MPH.2.
FOR ADDITIONAL INFORMATION.
1. SEE CITY OF DENTON STANDARD DETAILS
CITY OF DENTON
DATENO.REVISIONS APPROVED
DESIGN
BDE
DRAWN APPR.
KAR
SCALE DATE PROJ. NO.SHEET
Phone (214) 871-3311 Fax (214) 871-0757
Dallas, Texas 75202
1717 McKinney Avenue, Suite 1400Huitt-Zollars, Inc.
I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CSW11.dgnI:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\SHEETS\Phase Two\305837-CSW11.dgn1:404:45:38 PMTIME:DATE:9/4/2019alimPEN TABLE:I:\proj\R305837.01 - City of Denton Mckinney Street\10 CADD & BIM\10.6 MicroStation\Support\Plot\HZIHALF_BENT.TBLR305837
0
SCALE IN FEET
10 20 30 40
E. OF LOOP 288 TO W. OF GRISSOM ROAD
AL
OR BLAST - STOP CALL
BEFORE YOU DIG, DRILL,
REQUEST 48 HOURS NOTICE
TEXAS ONE CALL PARTICIPANT
CALL BEFORE YOU DIG!
TEXAS ONE CALL SYSTEM
1-800-DIG-TESS
2019
SEP
SIDEWALK PLAN
KENNETH A. ROBERTS
55446P
ROFES
SIONALENGINEERSTATEOFTEXASDERETSIGER
FIRM REGISTRATION NO. F-761
ON SEPTEMBER 4, 2019.
BY KENNETH A. ROBERTS, P.E. 55446
APPROVED FOR BIDDING & CONSTRUCTION
THE SEAL APPEARING ON THIS PLAN IS
S
S
S
D
E McKINNEY STREET
ATMOS ENERGY CORP
E McKINNEY STREET & TRINITY ROAD
THE WOODLANDS ON McKINNEY STREET LLC
LOT 146
LOT 143, 144 LOT 143, 144
TRINITY ROAD
E McKINNEY STREET &
McKINNEY STREET LLC
THE WOODLANDS ON
TRINITY ROAD
E McKINNEY STREET &
ON McKINNEY STREET LLC
THE WOODLANDS
VOL. 695, PG. 351
16' UTILITY EASEMENT
VOL. XX, PG. XX
UTILITY EASEMENT
VARIABLE WIDTH
VOL. XX, PG. XX
25' UTILITY EASEMENT
VOL. XX, PG. XX
16' UTILITY EASEMENT
VOL. XX, PG. XX
EASEMENT
30' TEMPORARY CONSTRUCTION
171+00 172+00 173+00 174+00 175+00
16" W
16" W 16" W
16" W 16" W 16" W
21" WW
21" WW21" WW16" W 16" W 16" W
21" WW
21" WW21" WW18" RCPD
18" RCP
18" RCP
16" W
RCP18" FUTURE EXTENSION)
(EMPTY UNTIL
18" RCP
(EMPTY UNTIL FUTURE EXTENSION)
24" RCP
(EMPTY UNTIL FUTURE EXTENSION)
24" RCP
MATCHLINE STA 170+50McKINNEY STREET
311
R.O.WEX.
R.O.WEX. 5.5'CL McKINNEY STREET
R.O.WEX.
6' SIDEWALK
LINK FENCE
EX. CHAIN
173+00
BID
ALTERNATE
END 6' SIDEWALK CONSTRUCTION
STA 171+00.00 114.5' R.O.W.