6612 - Electric Meter and Equipment, Addendum 1 - REVISED PRICING SHEETIFB 6612 - Pricing Sheet for SUPPLY OF ELECTRIC METERS AND EQUIPMENT-REVISED
Exhibit 1
The respondent shall complete the following section, which directly corresponds to the specifications. The contractor shall not make changes to this format.
Product Proposal Pricing (FOB DESTINATION):
Item #
SECTION A- ELECTRIC METERS with Trilliant Secure Mesh NIC card
1
2
2
3
4
5
6
7
8
9
10
11
12
13
14
15
SECTION B- Photovolatic Meters
16
17
18
19
SECTION C- ELECTRIC SOCKETS
20
21
SECTION D- SECONDARY INSTRUMENT RATED TRANSFORMERS
22
23
24
25
26
SECTION E- PRIMARY INSTRUMENT RATED TRANSFORMERS
27
28
29
30
31
32
33
34
35
36
37
SECTION F- TRILLIANT SECURE MESH AMI EQUIPMENT
38
39
40
41
42
Total Cost of Products (Annual)
*NOTE: PLEASE EMAIL THIS EXHIBIT 1 AS AN EXCEL FILE TO EBIDS@CITYOFDENTON.COM
EST. ANNUAL QTY
20
12
10
7000
510
40
20
40
20
30
40
300
48
200
5
5
5
5
50
40
120
300
30
6
36
60
6
6
3
3
3
3
3
3
3
3
3
1
1
1
1
1
UOM
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
Respondent's Company Name:
City and State:
Product Description
Meter, Single Phase, Class 100, 120V, 2 wire, 1s
Meter, Single Phase, Class 100, 120V, 2 wire, 1s w/ Disconnect under the cover
Meter, Single Phase, Class 100, 120V, 2 wire, 1s, w / kW Demand
Meter, Single Phase, Class 200, 240V, 3 wire, 2s with Disconnect under the cover
Meter, Single Phase, Class 200, 240V, 3 wire, 2s, w/ kW Demand
Meter, Single Phase, Class 200, 120-480V, 3 wire, 2s, w/ kW Demand
Meter, Single Phase, Class 320, 240V, 3 wire, 2s
Meter, Single Phase, Class 320, 120-480V, 3 wire, 2s, w / kW Demand
Meter, Single Phase, Class 20, 120-480V, 3 wire, 4s, w / kW Demand
Meter, Single Phase, Class 200, 120V, 3 wire, 12s /25s with Disconnect under the cover
Meter, Single Phase, Class 200, 120-480V, 3 wire, 12s/25s, w/ kW Demand
Meter, Three Phase, Class 200, 120-480V, 4 wire, 15-16s, w/ kW Demand
Meter, Three Phase, Class 320, 120-480V, 4 wire, 15-16s, w/ kW Demand
Meter, Three Phase, Class 20, 120-480V, 4 wire, 8-9s, w/ kW Demand
Meter, Three Phase, Class 20, 120-480V, 4 wire, 8-9s, kWH, kW/kVA Demand (4 quadrant kVA metering)
Option: KYZ Pulse Initiator Board
Meter, Three Phase, Class 20, 120-480V, 4 wire, 8-9s, kWH, kW/kVA Demand capable of alpha/numeric labeling of displays
Meter, Three Phase, Class 200, 120-480V, 4 wire, 15-16s, kWH, kW Demand capable of alpha/numeric labeling of displays
Meter, Single Phase, Class 200, 120-480V, 3 wire, 2s, kWH, kW Demand capable of alpha/numeric labeling of displays
Meter, Single Phase, Class 200, 240V, 3 wire, 2s with Disconnect under the cover capable of alpha/numeric labeling of the displays
Socket, Ring-less, 6 Terminal, 20 amp, One piece cover, Closure Plate, Seven Pole Test switch(Milbank #TS07-0105 or equivalent), Pre-wired with DME's color-coded wiring diagram for a
4S meter
Socket, Ring-less, 13 Terminal, 20 amp, One piece cover, Closure Plate, Ten Pole Test switch(Milbank #TS10-0109 or equivalent), Pre-wired with DME's color-coded wiring diagram for a
8-9S meter
Current Transformers: 600 volt, over-bushing type 500:5, ANSI meter accuracy class .3B-0.1, rating factor of 4.0 @ 30 C. Extended range (4%-40% at .6 accuracy as defined by IEEE C57.13)
Current Transformers: 600 volt, over-bushing type 1000:5, ANSI meter accuracy class .3B-0.9, rating factor of 2.0 @ 30 C. Extended range (4%-40% at .6 accuracy as defined by IEEE C57.13)
Current Transformers: 600 volt, over-bushing type 2000:5, ANSI meter accuracy class .3B-1.8, rating factor of 2.0 @ 30 C. Extended range (4%-40% at .6 accuracy as difined by C57.13)
Current Transformers: 100:5 ratio, 600 volt, window type. 2.5" window, ANSI meter accuracy class .3B-0.5, rating factor of 4.0 @ 30 C.
Current Transformers: 500:5 ratio, 600 volt, window type. 2.5" window, ANSI meter accuracy class .3B-0.5, rating factor of 4.0 @ 30 C. Extended range (4%-40% at .6 accuracy as difined
by IEEE C57.13)
Voltage Transformers: ANSI accuracy class 0.3 thru Burden Z, Thermal Rating 1500 VA at 30 degrees C ambient, 8400:120 voltage rating, single bushing, 110 KV BIL, ABB Type VOZ-11M, Part
#7525A91G07 or equal
Current Transformers: ANSI accuracy class .3 thru B-0.5, 110 KV, BIL, 13,800 nominal or 15 KV acceptable
15:5 ABB Type KON-11, Part #7524A25G02 or equal
20:5 ABB Type KON-11, Part #7524A25G03 or equal
25:5 ABB Type KON-11, Part #7524A25G04 or equal
30:5 ABB Type KON-11, Part #7524A25G05 or equal
40:5 ABB Type KON-11, Part #7524A25G06 or equal
50:5 ABB Type KON-11, Part #7524A25G07 or equal
100:5 ABB Type KON-11, Part #7524A25G09 or equal
200:5 ABB Type KON-11, Part #7524A25G11 or equal
200:5 ratio Primary Current Transformer Accuracy class 0.15% extended range, RF 1.5 @ 30c, 13,800v or 15kV acceptable
Trilliant Secure Mesh PSU Card
Trilliant Secure Mesh PSU
Trilliant Secure Mesh Extender Bridge
Trilliant Secure Mesh Repeaters
Trilliant Secure Mesh Gateway
Unit Price
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Extended Price
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Estimated Delivery ARO (Days)