6576C - Construction of Cooper Creek Interceptor I & II, Addendum2 - Additional Info & ModificationADDENDUM NO.2
TO
PLANS, SPECIFICATIONS AND CONTRACT DOCUMENTS
FOR
CITY OF DENTON, TEXAS
COOPER CREEK INTERCEPTOR I & II
IFB 6576
TO: PROSPECTIVE BIDDERS AND PLAN HOLDERS
The Plans, Specifications and Contract Documents shall be modified as required by the
following items:
Ttam ')-1
PLANS: Multiple Sheets: Additional Information
The vent elevations for the vented manholes were left off of the construction plans. The
following table specifies the elevation for the manhole vent at each vented manhole:
Manhole Plan Set Elevation
13+89.70 Cooper I 578.00
29+75.69 Cooper I 585.00
10+35.09 Cooper II 590.00
21+14.98 Cooper II 592.00
33+93.44 Cooper II 596.00
Item 2-2
PLANS: Sheet 20, Detail U208A: Modification
Note 2 of Detail U208A is incorrect. Non -pressurized pipe does not require a longitudinal thrust
restraint system. Only vertical restraints through casing spacers are required.
All items in conflict with this addendum are hereby deleted.
THIS ADDENDUM IS MADE PART OF THE PLANS, SPECIFICATIONS AND
CONTRACT DOCUMENTS AND SHALL BE ACKNOWLEDGED ON THE
PROPOSAL.