Loading...
7200 IFB-- ADDENDUM #4 - Main DocumentAddendum No. 4 File #/IFB# 7200 DTN12314 – North-South Phase III 42-inch Water Transmission Main DTN12314 CITY OF DENTON NORTH-SOUTH PHASE III 42-INCH WATER TRANMISSION MAIN ADDENDUM NO. 4 IFB #7200 NOVEMBER 14th, 2019 BID DATE: Thursday, November 21st, 2019, 11:00 a.m. The following additions, deletions, modifications, or clarifications shall be made to the appropriate sections of the plans and specifications and shall become a part of the Contract Documents. Bidders shall acknowledge receipt of this Addendum in the space provided on the Bid form. QUESTIONS: NOTE: Any questions from IONWAVE not answered in this addendum will be answered in subsequent addendum. 1. PDV – Section 33 11 13.13/ 2.03.A.2 calls for CP reinforcement, when PDV >6,000, in accordance with AWWA M11. Respectfully requesting this paragraph is revised to fall in line with the current (5th) edition of AWWA M11, as referenced on 33 11 13.13/ 1.04.4, which allows ICT/CLR reinforcement types for PDV< 9,000 a. Paragraph 2.03.A.1.2 will be replaced with The fittings and specials shall be designed in accordance with AWWA C208 and AWWA M11, except that crotch plates shall be used for outlet reinforcement for all pressure diameter values (PDVs) greater than 6000, collars may only be used when d/D is less than or equal to 0.7 and the M factor shall not be less than 1.0 but PDV/4000 for PDVs between 4000 and 6000 unless otherwise specified. Where indicated on the Drawings, collars or wrappers shall be used in lieu of crotch plates to allow for working space and supports. 2. Please confirm whether the city or the contractor is responsible for materials testing. The general conditions, 13.03 B, states that if the contract requires it then it is to be done by the contractor but nowhere else in the documents does it call for the contractor to do the testing. If the testing is to be done by the contractor, it is requested that a line item for testing be included and it be added to the measurement and payment to state that the item is for the contractor supplied testing. a. Contractor is responsible. b. A bid item can be added. 3. Addendum #1 added 37 LF of tunnel on PL-4 but the bid item did not change. Will there be a new bid form with the tunnel item adjusted? a. Casing by bore measurement will be revised on bid form. 4. There is 27 LF of 60" Steel Casing by Open Cut that is missing from the bid item (assuming the section on PL-1). Can you please revise the bid form to reflect the additional 27 LF? a. Casing by open cut measurement will be revised on bid form. CONTRACT DOCUMENTS: Addendum No. 4 File #/IFB# 7200 DTN12314 – North-South Phase III 42-inch Water Transmission Main DTN12314 SPECIFICATIONS: A4-1 Bid Proposal Form A. Replace Bid Proposal Form with Attached A4-2 Special Requirements and Bid Item Descriptions A. Add BID ITEM 35 Material Testing. This is material testing required in the project plans and specification. Payment for this item shall be at the contract unit price per lump sum. A4-3 Section 33 11 13.13 A. Remove Paragraph 2.03.A.1.2 i. The fittings and specials shall be designed in accordance with AWWA C208 and AWWA M11 except that crotch plates shall be used for outlet reinforcement for all Pressure Diameter Valves values (PDV), greater than 6000 unless otherwise specified. Where indicated on the Drawings, collars or wrappers shall be used in lieu of crotch plates to allow working space and supports. Wrappers and collars shall meet ASME Standards. As an alternate to crotch plates, collars or wrappers may be used when designed in accordance with ASME Section VIII, Division 1. B. Add Paragraph 2.03.A.1.2 i. The fittings and specials shall be designed in accordance with AWWA C208 and AWWA M11, except that crotch plates shall be used for outlet reinforcement for all pressure diameter values (PDVs) greater than 6000, collars may only be used when d/D is less than or equal to 0.7 and the M factor shall not be less than 1.0 but PDV/4000 for PDVs between 4000 and 6000 unless otherwise specified. Where indicated on the Drawings, collars or wrappers shall be used in lieu of crotch plates to allow for working space and supports. 11/14/2019 Addendum No. 4 File #/IFB# 7200 DTN12314 – North-South Phase III 42-inch Water Transmission Main DTN12314 END OF ADDENDUM NO. 3 To:From:CONTRACTOR NAME ADDRESS CITY CONTACT PROJ.:North-South Phase 3 - 42" Water Transmission Main PHONE IFB:7200 EMAIL ENG PMO:180006 SECTION 00 42 43 Item No.Spec. Section No. Description of work UOM BID QTY Unit Price Extended Price 1 COD NCTCOG AM ITEM 203.3 Mobilization LS 1 2 COD NCTCOG AM ITEM 203.3 General Site Preparation LS 1 3 13 47 13 Corrosion Protection LS 1 4 COD NCTCOG AM ITEM 201 SWPPP Plan and Implementation LS 1 5 COD NCTCOG AM ITEM 201 Traffic Control Plan and Implemenation LS 1 6 2 Portable Changeable Message Signs DAY 270 7 COD NCTCOG AM ITEM 501.14 6'' C900 DR-14 PVC Water Line LF 21 8 COD NCTCOG AM ITEM 501.14 12'' C900 DR-14 PVC Water Line LF 918 9 COD NCTCOG AM ITEM 503.3 60”x3/4” Thick Steel Casing By Bore LF 274 10 COD NCTCOG AM ITEM 503.3 60''x3/4'' Thick Steel Casing By Open Cut LF 172 11 COD NCTCOG AM 107.19.3 Excavation Protection (Trench Safety)LF 4,910 12 8" Blowoff Valve Assembly EA 1 13 COD NCTCOG AM ITEM 502.3 Fire Hydrant Assembly EA 3 14 Connect to Existing Fire Hydrant Assembly EA 1 15 33 12 16.23 6'' Gate Valve and Box EA 1 16 33 12 16.23 12'' Gate Valve and Box EA 1 17 33 12 16.26 42'' Butterfly Valve Assembly EA 3 18 COD NCTCOG AM ITEM 502.6.3 2'' Type 1 CAV Assembly EA 1 19 COD NCTCOG AM ITEM 502.6.3 4'' Type 2 CAV Assembly EA 2 20 Connect to Existing 16'' Water Line EA 2 21 Connect to Existing 12'' Water Line EA 2 22 Connect to Existing 42'' Water Line EA 2 23 COD NCTCOG AM ITEM 502.10.3A Reconnect Water Meter (long) EA 2 24 COD NCTCOG AM ITEM 502.10.3A Reconnect Water Meter (short) EA 3 25 Remove exisitng 16" and 20" Water Line LF 1,475 26 Asphalt Pavement Repair SY 7,200 27 Sidewalk Replacement SY 13 28 Curb and Gutter Replacement LF 1,601 29 Manway Vault EA 2 30 Temporary Asphalt Repair SY 500 31 Asbestos Removal from Property (Each Property)EA 3 30,000.00$ 90,000.00$ 32 Remove Existing Building(s) from Property (Each Property)EA 3 33 COD NCTCOG AM ITEM 501.14 16'' DIP Special Class 52 LF 20 34 Ductile Iron Fittings TON 4 35 Material Testing LS 1 1A 33 11 13.13 & 09 97 16 42 Inch Water Line (Poly Coated Steel)LF 4,225 1B 33 05 01.05 42 Inch Water Line (Bar-Wrapped)LF 4,225 TOTAL BASE BID PLUS CHOSEN ALTERNATE BID: 5% CONTENGENCY: North-South Phase 3 - 42" Water Transmission Main TOTAL BASE BID: Alternate A Bid- Poly-Coated Steel Pipe City of Denton - Capital Projects 901-B Texas Street Denton, TX 76209 Laura Hermosillo/Purchasing Dept. BIDDERS APPLICATION - UNIT PRICE BID TOTAL ALT. "A" BID: TOTAL ALT. "B" BID: Alternate B Bid-Bar Wrapped Pipe TOTAL PROJECT BID: CONTRACTOR NAME