Loading...
6395 - Landfill Cell 3 Liner Construction and Site Improvements, 4.Drawings/ PlansD C B A 1 2 3 4 5 1 2 3 4 5 ISSUING OFFICE: NO DESCRIPTIONDATE PROJECT NO: KEY PLAN FRISCO 0172-16 CITY OF DENTON MSW LANDFILL CELL 3 LINER CONSTRUCTION AND 1527 SOUTH MAYHILL ROAD DENTON, TEXAS 76208 SITE IMPROVEMENTSPROF E SSIONA L E N G IN EERL I C E N S E D S T A T E OF TEXA S PARKHILL S M IT H & COOPER,I N C. F-560FRANK E. PUGSLEY 98460 02/16/2017 DENTON SHEET TITLESHEET NO. PROJECT LOCATION MAP, VICINITY MAP & SHEET INDEXG-002 COVER SHEETG-001 V-001 TOPOGRAPHIC SURVEY G-002 C-001 OVERALL SITE PLAN DENTON 0 1200600 PROJECT LOCATION GENERAL NOTES THE CONTRACTOR SHALL VISIT AND FAMILIARIZE HIMSELF / HERSELF WITH THE PROJECT SITE PRIOR TO SUBMITTING BIDS. IT WILL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE, PROTECT, AND REPLACE ALL UNDERGROUND UTILITY LINES AT NO EXTRA COST TO THE OWNER WHEN LINES ARE DISTURBED AS A RESULT OF THE WORK. SERVICE SHALL BE PROVIDED TO USER AT ALL TIMES. IT WILL BE THE RESPONSIBILITY OF THE CONTRACTOR TO SCHEDULE AND PERFORM HIS/HER WORK TO ASSURE PROPER PASSAGE OF STORM RUNOFF DURING THE COURSE OF OPERATIONS. ALL LABOR, TOOLS, EQUIPMENT, AND SUPERVISION REQUIRED TO ASSURE SUCH PROPER PASSAGE OF RUNOFF WATER AND ANY REMOVAL OR HANDLING OF WATER IN ORDER TO MAINTAIN DRY CONDITIONS SHALL BE CONSIDERED INCIDENTAL TO THE WORK, AND SHALL BE AT THE EXPENSE OF THE CONTRACTOR. THE CONTRACTOR SHALL COORDINATE THE CONSTRUCTION SCHEDULE WITH THE CITY OF DENTON, ALL UTILITIES, AND ALL OTHER AGENCIES WITH JURISDICTION OVER THE PROJECT. ALL EXISTING PAVEMENT, ADJACENT UTILITIES, STRUCTURES, ETC., DISTURBED AS A RESULT OF THE CONSTRUCTION, SHALL BE REPLACED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. THE DRAWINGS INDICATE HORIZONTAL AND VERTICAL CONTROL REFERENCE POINTS ONLY. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND GRADES BEFORE PROCEEDING WITH THE WORK. ANY DISCREPANCIES FOUND SHALL BE REPORTED IMMEDIATELY TO THE ENGINEER, OTHERWISE THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THEIR CORRECTNESS. ALL WORK REQUIRED BY THESE PLANS SHALL BE CONDUCTED IN CONFORMANCE WITH THE CURRENT SAFETY CODES AND STANDARDS HAVING JURISDICTION OVER THE PROJECT. THE PROJECT'S INTERNAL AND PERIMETER HORIZONTAL AND VERTICAL CONTROL WAS FURNISHED BY COLEMAN & ASSOCIATES LAND SURVEYING. UNDERGROUND UTILITIES WERE LOCATED VISUALLY AND FROM AS-BUILT RECORDS. THERE WERE NO EXPOSURES OF UNDERGROUND UTILITIES CONDUCTED FOR LOCATION. THE NORMAL HOURS OF OPERATION FOR THE LANDFILL ARE FROM 7:00 A.M. TO 5:00 P.M. MONDAY THROUGH SATURDAY. THE CONTRACTOR WILL NOT BE ALLOWED TO WORK BEYOND THE LANDFILL NORMAL HOURS OF OPERATION. THE CONTRACTOR WILL BE RESPONSIBLE FOR SECURING THE LANDFILL PREMISES AT THE PROJECT SITE. RE-USE WATER SHALL BE AVAILABLE TO THE CONTRACTOR AT NO COST. IF AT ANY TIME CONSTRUCTION INHIBITS NORMAL LANDFILL TRAFFIC, THEN IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE A FLAGMAN OR SIGNS FOR TRAFFIC CONTROL. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. C-002 C-003 C-004 C-006 C-007 C-008 C-009 C-010 C-011 C-012 C-013 C-014 C-015 C-016 LANDFILL LOCATION S-001 E-101 E-102 E-103 EROSION CONTROL PLANG-003 LANDFILL - SUBGRADE PLAN LANDFILL - CLAY LINER PLAN LANDFILL - PROTECTIVE COVER AND LEACHATE COLL SYS PLAN LINER SECTIONS AND DETAILS OLD EDWARDS ROAD - PLAN & PROFILE STA. 0+00 TO STA. 12+00 PRE-CAST WALL PLAN & PROFILE, STA. 0+00 TO STA. 12+00 LITTER FENCE - SITE PLAN TRUCK SCALE - SITE PLAN TRUCK SCALE - DEMOLITION PLAN TRUCK SCALE - PAVEMENT & GRADING PLAN ELR SYSTEM - TANK PLAN REST AREA - SITE PLAN REST AREA - BUILDING PLAN REST AREA - DETAILS TRUCK SCALE - SECTIONS & DETAILS ELECTRICAL SITE PLAN ELECTRICAL REST AREA ELECTRICAL TANK AND PUMP STATION PRE-CAST WALL PLAN & PROFILE, STA. 12+00 TO STA. 15+75 ELECTRICAL DETAILSE-501 C-005 C-006A OLD EDWARDS ROAD - PLAN & PROFILE STA. 12+00 TO STA. 19+25 C-017 DETAILS FUTURE TIE-IN AREA 0.5% SLOPE LEACHATE COLLECTION TRENCH 3:1 SIDESLOPE 0.5% SLOPE LINER TIE-IN AREA 3:1 SIDESLOPE TOE 1.0% SLOPE1.0% SLOPETOED C B A 1 2 3 4 5 1 2 3 4 5 ISSUING OFFICE: NO DESCRIPTIONDATE PROJECT NO: KEY PLAN FRISCO 0172-16 CITY OF DENTON MSW LANDFILL CELL 3 LINER CONSTRUCTION AND 1527 SOUTH MAYHILL ROAD DENTON, TEXAS 76208 SITE IMPROVEMENTSPROF E SSIONA L E N G INEERL I C E N S E D S T A T E OF TEXA S PARKHILL S M IT H & COOPER,I N C. F-560FRANK E. PUGSLEY 98460 02/16/2017 G-003 100 200 0 PERMIT BOUNDARY EXISTING LINER EXISTING CONTOURS PROPOSED CONTOURS LIMITS OF DISTURBANCE GRADE BREAK 3H:1V SLOPE LINER TIE-IN AREA LEGEND 566 PREVIOUSLY LINED AREA PREVIOUSLY LINED AREA A1 SILT FENCE DETAIL NO SCALE 90° 1 3 4 2 SILT FENCE, A1/G-003 FLOW DIRECTION (EXISTING) FLOW DIRECTION (PROPOSED) 5 NOTES: CONTRACTOR WILL BE AN "OPERATOR" ON THIS PROJECT AND WILL BE REQUIRED TO OBTAIN COVERAGE UNDER A TPDES GENERAL PERMIT FOR STORM WATER DISCHARGES ASSOCIATED WITH CONSTRUCTION ACTIVITY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO ASSURE THAT CONTRACTOR'S ACTIVITIES ARE IN COMPLIANCE WITH ALL APPLICABLE PERMIT CONDITIONS. SHOULD ANY FIELD INSPECTIONS BY THE CONTRACTOR, OWNER'S REPRESENTATIVE, OR OTHER AUTHORITY HAVING JURISDICTION INDICATE THAT CONTRACTOR'S MEASURES OR ACTIVITIES ARE NOT IN COMPLIANCE WITH PERMIT CONDITIONS, CONTRACTOR SHALL IMPLEMENT WHATEVER MEASURES NECESSARY TO BRING THE PROJECT INTO COMPLIANCE. LOCATION OF CONSTRUCTION STAGING AREA IS TO BE COORDINATED WITH OWNER. IF CONSTRUCTION STAGING AREA IS LOCATED OUTSIDE LIMITS OF DISTURBANCE, THEN THE ADDITIONAL AREA SHALL BE ADDED TO THE LIMITS OF DISTURBANCE SHOWN ON PLANS. EROSION CONTROL PLAN TO BE ADJUSTED BY CONTRACTOR AS NECESSARY. TURN ALL SILT FENCES 45° UP SLOPE AT END OF REACH FOR A MINIMUM OF 15 FEET. CONSTRUCTION STAGING AREA TO BE RETURNED TO PRE-CONSTRUCTION CONDITIONS UPON COMPLETION OF CONSTRUCTION. NO WET LANDS ON SITE. NO OFF-SITE BORROW AREAS. TOTAL DISTURBED AREA = 21.6± ACRES OFP.O. BOX 686 · DENTON, TEXAS 76202 PH(940)565-8215, FAX (940)565-9800 W W W . C O L E M A N S U R V E Y I N G . C O M REGISTRATION # 10095100 L AND S U R V EYING COLEM A N & A SSO C . Coleman & Assoc. Land Surveying 2016 COLEMAN & ASSOC. SURVEYINGDENTON COUNTY, TEXAS CITY OF DENTON LANDFILL CELLS 3D, 3C, & PART OF 3B G. WALKER SURVEY ABSTRACT 1330 CITY OF DENTON1" = 60'010115-1991City of Denton Landfill David Dugger PRE-CONSTRUCTION TOPOGRAPHIC SURVEY 08-04-16THIS DOCUMENTIS RELEASED FOR THE PURPOSEOF INTERIM REVIEW UNDER THEAUTHORITY OF WILLIAM M. COLEMAN,RPLS 4001 DURING AUGUST 2016. IT ISNOT TO BE USED FOR RECORDING,CONSTRUCTION, BIDDING, OR PERMITPURPOSES. THIS DOCUMENT IS NOTTO BE RELIED UPON AS ACOMPLETE SURVEY ANDSHALL NOTBE RECORDED1206001030N D C B A 1 2 3 4 5 1 2 3 4 5 ISSUING OFFICE: NO DESCRIPTIONDATE PROJECT NO: KEY PLAN FRISCO 0172-16 CITY OF DENTON MSW LANDFILL CELL 3 LINER CONSTRUCTION AND 1527 SOUTH MAYHILL ROAD DENTON, TEXAS 76208 SITE IMPROVEMENTSPROF E SSIONA L E N G IN EERL I C E N S E D S T A T E OF TEXA S PARKHILL S M IT H & COOPER,I N C. F-560FRANK E. PUGSLEY 98460 02/16/2017 C-001 200 4000 1. ALL CONSTRUCTION TRAFFIC MUST ENTER SITE FROM SPENCER ROAD AND MAYHILL. 2.BENCH MARKS AND CONTROL POINTS FOR HORIZONTAL AND VERTICAL CONTROL WERE PROVIDED BY COLEMAN & ASSOCIATES LAND SURVEYING: 300 N. ELM ST. #200, DENTON, TEXAS 76201, PH. 940-565-8215, FAX 940-565-9800. 3. CONTRACTOR SHALL STOCKPILE CLAY AND SAND IN DESIGNATED STOCKPILE AREAS. EXCAVATED CLAY MATERIAL MUST BE TESTED TO MEET TCEQ CRITERIA FOR LINERS PRIOR TO PLACEMENT IN THE CLAY LINER STOCKPILE AREA. EXCAVATED MATERIAL NOT MEETING TCEQ CRITERIA FOR LINERS SHALL BE PLACED IN THE SAND/COVER STOCKPILE LOCATIONS OF THE STOCKPILES TO BE DESIGNATED AT THE PRE-CONSTRUCTION CONFERENCE. 4. CONTRACTOR SHALL CONSTRUC/INSTALL AND/OR IMPLEMENT ALL TEMPORARY DRAINAGE AND SOIL EROSION AND SEDIMENT CONTROL FEATURES/MEASURES SO AS TO CONFORM TO DETAILS AND SPECIFICATIONS INCLUDED IN THE "STORMWATER QUALITY BEST MANAGEMENT PRACTICES FOR CONSTRUCTION ACTIVITIES" MANUAL PUBLISHED BY NORTH CENTRAL TEXAS COUNCIL OF GOVERNMENTS (NCTCOG). ALL CONTRACTOR ACTIVITIES SHALL BE CONDUCTED IN SUCH A MATER AS TO PREVENT SOIL EROSION AND SEDIMENT MIGRATION AT THE SITE. NOTES CELL 3A/B CELL 4A/BCELL 2 CELL 5 CELL 1 CELL 1590 LANDFILL CELL CONSTRUCTION SEE SHEET C-002 THRU C-005 TRUCK SCALE/BY-PASS LANE SEE SHEET C-010 THRU C-012 REST AREA SEE SHEET C-014 THRU C-016 LITTER FENCE SEE SHEET C-009 STREET OVERLAY AND PRE-CAST SCREENING WALL SEE SHEET C-006 THRU C-008 LEGEND PROPERTY LINE PERMIT BOUNDARY PREVIOUSLY CONSTRUCTED LANDFILL WORK IN THIS CONTRACT TANK, PUMP STATION & ELR SYSTEM/PIPING SEE SHEET C-013 STOCKPILE AREA STOCKPILE AREA STOCKPILE AREA FUTURE TIE-IN AREA 0.5% SLOPE LEACHATE COLLECTION TRENCH 3:1 SIDESLOPE 0.5% SLOPE LINER TIE-IN AREA 3:1 SIDESLOPE TOE 1.0% SLOPE1.0% SLOPETOE SEE NOTE 2 GRADE TO EXISTING DITCH SEE NOTE 3 SEE NOTE 4 300.00' (TYP.) UNDERDRAIN TYPICAL OF 4 SEE D1/C-006 CELL ENTRANCE GRADE TO THE EAST TO MATCH EXISTING 409.00'40.00'960.00'40.00' CELL ENTRANCE GRADE TO THE EAST TO MATCH EXISTING 60-LF 36" DIA. RCP TYPICAL OF 2 CONTROL POINT TABLE POINT # 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 NORTHING 7,118,282.29 7,118,481.77 7,118,718.75 7,118,918.83 7,119,118.92 7,117,686.99 7,117,886.49 7,118,085.99 7,118,285.49 7,118,484.99 7,118,575.20 7,118,720.46 7,118,920.29 7,119,120.12 7,119,204.59 EASTING 2,402,081.88 2,402,096.35 2,402,104.81 2,402,106.88 2,402,108.96 2,401,994.26 2,402,008.39 2,402,022.53 2,402,036.67 2,402,050.81 2,402,057.20 2,402,063.16 2,402,071.36 2,402,079.56 2,402,083.54 ELEVATION 567.71 568.65 569.87 570.92 571.97 579.66 580.71 581.77 582.82 583.88 584.35 583.77 582.77 581.78 581.61 CONTROL POINT TABLE POINT # 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 NORTHING 7,117,595.73 7,117,597.39 7,118,572.64 7,119,263.90 7,119,203.63 7,119,200.32 7,119,197.01 7,119,196.60 7,119,196.20 7,119,251.84 7,119,261.71 7,119,255.17 7,119,260.95 7,118,547.78 7,117,578.96 7,117,588.81 7,118,390.70 7,117,683.86 7,117,883.34 7,118,082.81 EASTING 2,402,032.03 2,401,987.91 2,402,102.94 2,402,085.46 2,402,109.84 2,402,203.76 2,402,298.43 2,402,430.50 2,402,559.44 2,402,571.49 2,402,581.86 2,402,440.72 2,402,205.62 2,402,543.77 2,402,499.12 2,402,238.44 2,402,267.98 2,402,038.44 2,402,052.92 2,402,067.40 ELEVATION 570.89 578.80 569.07 592.83 572.76 571.76 570.78 571.76 572.73 589.37 589.53 590.33 591.98 569.82 564.84 562.10 566.73 564.89 565.83 566.77 D C B A 1 2 3 4 5 1 2 3 4 5 ISSUING OFFICE: NO DESCRIPTIONDATE PROJECT NO: KEY PLAN FRISCO 0172-16 CITY OF DENTON MSW LANDFILL CELL 3 LINER CONSTRUCTION AND 1527 SOUTH MAYHILL ROAD DENTON, TEXAS 76208 SITE IMPROVEMENTSPROF E SSIONA L E N G IN EERL I C E N S E D S T A T E OF TEXA S PARKHILL S M IT H & COOPER,I N C. F-560FRANK E. PUGSLEY 98460 02/16/2017 C-002 100 200 0 PERMIT BOUNDARY EXISTING LINER EXISTING CONTOURS PROPOSED CONTOURS LIMITS OF EXCAVATION GRADE BREAK UNDERDRAIN, SEE D1/C-005 3H:1V SLOPE LINER TIE-IN AREA DOUBLE SIDED GEOCOMPOSITE STRIP DRAIN LAYOUT CONTROL POINT LEGEND 566 1. PROPOSED CONTOURS REPRESENT THE TOP OF SUBGRADE. 2. REMOVE EXISTING POWER POLES (2) AND GROUNDWATER MANHOLE. BACKFILL MANHOLE WITH GENERAL FILL AS NEEDED TO CONSTRUCT SUBGRADE. 3. 12' WIDE DOUBLE SIDED GEOCOMPOSITE 24' O.C. ON FLOOR 4. 4' WIDE DOUBLE SIDED GEOCOMPOSITE 25' O.C. ON SIDE SLOPE. NOTESB1/C-005D4/C-005B3/C-005 C1/C-005 A2/C-005 201 A1/C-005 PREVIOUSLY LINED AREA PREVIOUSLY LINED AREA B3/C-005 FUTURE TIE-IN AREA 0.5% SLOPE LEACHATE COLLECTION TRENCH 3:1 SIDESLOPE 0.5% SLOPE LINER TIE-IN AREA 3:1 SIDESLOPE TOE 1.0% SLOPE1.0% SLOPETOED C B A 1 2 3 4 5 1 2 3 4 5 ISSUING OFFICE: NO DESCRIPTIONDATE PROJECT NO: KEY PLAN FRISCO 0172-16 CITY OF DENTON MSW LANDFILL CELL 3 LINER CONSTRUCTION AND 1527 SOUTH MAYHILL ROAD DENTON, TEXAS 76208 SITE IMPROVEMENTSPROF E SSIONA L E N G IN EERL I C E N S E D S T A T E OF TEXA S PARKHILL S M IT H & COOPER,I N C. F-560FRANK E. PUGSLEY 98460 02/16/2017 C-003 100 200 0 PERMIT BOUNDARY EXISTING LINER EXISTING CONTOURS PROPOSED CONTOURS LIMITS OF EXCAVATION GRADE BREAK 3H:1V SLOPE LINER TIE-IN AREA LEGEND 568 1. PROPOSED CONTOURS REPRESENT TOP OF CLAY LINER. 2. CLAY LINER SHALL BE INSTALLED AS SPECIFIED. NOTESB1/C-005D4/C-005B3/C-005 C1/C-005 A2/C-005 A1/C-005 PREVIOUSLY LINED AREA PREVIOUSLY LINED AREA B3/C-005 FUTURE TIE-IN AREA 0.5% SLOPE LEACHATE COLLECTION TRENCH 3:1 SIDESLOPE 0.5% SLOPE LINER TIE-IN AREA 3:1 SIDESLOPE TOE 1.0% SLOPE1.0% SLOPECELL ENTRANCE CELL ENTRANCE D C B A 1 2 3 4 5 1 2 3 4 5 ISSUING OFFICE: NO DESCRIPTIONDATE PROJECT NO: KEY PLAN FRISCO 0172-16 CITY OF DENTON MSW LANDFILL CELL 3 LINER CONSTRUCTION AND 1527 SOUTH MAYHILL ROAD DENTON, TEXAS 76208 SITE IMPROVEMENTSPROF E SSIONA L E N G IN EERL I C E N S E D S T A T E OF TEXA S PARKHILL S M IT H & COOPER,I N C. F-560FRANK E. PUGSLEY 98460 02/16/2017 C-004 100 200 0 PERMIT BOUNDARY EXISTING LINER EXISTING CONTOURS PROPOSED CONTOURS LIMITS OF EXCAVATION GRADE BREAK 3H:1V SLOPE LINER TIE-IN AREA LEGEND 570 1. PROPOSED CONTOURS REPRESENT TOP OF PROTECTIVE COVER. 2. PROTECTIVE COVER SHALL BE INSTALLED AS SPECIFIED. NOTES PREVIOUSLY LINED AREA PREVIOUSLY LINED AREA B1/C-005D4/C-005B3/C-005 C1/C-005 A2/C-005 A1/C-005 B3/C-005 D C B A 1 2 3 4 5 1 2 3 4 5 ISSUING OFFICE: NO DESCRIPTIONDATE PROJECT NO: KEY PLAN FRISCO 0172-16 CITY OF DENTON MSW LANDFILL CELL 3 LINER CONSTRUCTION AND 1527 SOUTH MAYHILL ROAD DENTON, TEXAS 76208 SITE IMPROVEMENTSPROF E SSIONA L E N G IN EERL I C E N S E D S T A T E OF TEXA S PARKHILL S M IT H & COOPER,I N C. F-560FRANK E. PUGSLEY 98460 02/16/2017 C-005 10+75 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 702703 704705 9+00 10+00 11+00 12+00 714 CONTROL POINT TABLE POINT # 701 702 703 704 705 706 NORTHING 7116497.63 7116474.76 7116508.84 7116473.76 7116468.34 7116457.25 EASTING 2401271.71 2402346.45 2401242.56 2401252.82 2401241.11 2402171.05 ELEVATION 594.49 0.00 0.00 0.00 0.00 588.96 DESCRIPTION ALIGNMENT ALIGNMENT LIP OF CURB LIP OF CURB LIP OF CURB CONCRETE CONTROL POINT TABLE POINT # 707 708 709 710 711 712 NORTHING 7116455.67 7116477.16 7116478.74 7116455.02 7116450.52 7116454.75 EASTING 2402246.04 2402246.49 2402171.51 2402272.96 2402272.86 2402171.00 ELEVATION 588.50 588.30 589.39 587.50 587.50 588.91 DESCRIPTION CONCRETE FILL LIMIT LIP OF CURB INTLET INTLET LIP OF CURB CONTROL POINT TABLE POINT # 713 714 715 NORTHING 7116466.75 7116463.15 7116063.23 EASTING 2402171.25 2402344.89 2402336.60 ELEVATION 588.91 0.00 0.00 DESCRIPTION LIP OF CURB PC RADIUS A1 SECTION SCALE: 1" =10' * FROM STA. 0+00.00 TO STA. 9+00.00 24.00' * D C B A 1 2 3 4 5 1 2 3 4 5 ISSUING OFFICE: NO DESCRIPTIONDATE PROJECT NO: KEY PLAN FRISCO 0172-16 CITY OF DENTON MSW LANDFILL CELL 3 LINER CONSTRUCTION AND 1527 SOUTH MAYHILL ROAD DENTON, TEXAS 76208 SITE IMPROVEMENTSPROF E SSIONA L E N G IN EERL I C E N S E D S T A T E OF TEXA S PARKHILL S M IT H & COOPER,I N C. F-560FRANK E. PUGSLEY 98460 02/16/2017 C-006 50 1000 LEGEND 560 PROPERTY LINE PERMIT BOUNDARY EXISTING CONTOURS PROPOSED CONTOURS ASPHALT PAVEMENT, REF C3/C-006 FILL MATERIAL 4.5' WIDE CONCRETE/FLUME AND CURBA1/C-006REF C-007 B2/C-006 OLD EDWARDS ROAD MAYHILL ROADEXISTING GROUND PROPOSED CURB ALIGNMENT PROPOSED LIP OF CURB AS INDICATED BY:00 KEY NOTES 1 DEMOLISH EXISTING CONCRETE CURB, INSTALL NEW CURB AND MATCH EXISTING LIP OF CURB 2 35' LAY-DOWN CURB SEGMENT, CENTERED ON EXISTING ROAD. 3 MATCH EXISTING LIP OF CURB FROM STA. 10+01.93 TO STA. 14+27.58 1 NORTH LIP OF CURB - PROFILE 1 B2 6 1/8"6"6"7 1/2"12"7 1/2"4 1/4" 5 3/4" 9 11/16" 2'-0" 4'-6" (FROM STA. 9+00 TO 10+02, SOUTH CURB) R = 2' R = 3' C3/C-006 5"DROP LIP SECTION B2/C-006 2 35' B2/C-006 LAY-DOWN CURB SECTION B2/C-006 DROP LIP SECTION B2/C-006 ** MATCH EXISTING SURFACE ** ** ** ** L ROAD - PROFILEC PROPOSED L OF ROAD ALIGNMENT C 715R400.00'* TRANSITION FROM STA. 10+01.93 TO STA. 10+50.00 3 ** ** A2 SECTION SCALE: 1" =10' * FROM STA. 10+50.00 TO STA. 14+84.83 C2 SECTION SCALE: 1" =10' * FROM STA. 15+40.98 TO STA. 15+89.78 D C B A 1 2 3 4 5 1 2 3 4 5 ISSUING OFFICE: NO DESCRIPTIONDATE PROJECT NO: KEY PLAN FRISCO 0172-16 CITY OF DENTON MSW LANDFILL CELL 3 LINER CONSTRUCTION AND 1527 SOUTH MAYHILL ROAD DENTON, TEXAS 76208 SITE IMPROVEMENTSPROF E SSIONA L E N G INEERL I C E N S E D S T A T E OF TEXA S PARKHILL S M IT H & COOPER,I N C. F-560FRANK E. PUGSLEY 98460 02/16/2017 C-006A 50 1000 OLD EDWARDS ROAD CELL 4 (PREVIOUSLY LINED) EXISTING GROUND PROPOSED ROAD L ALIGNMENT PROPOSED ROAD LC C2/C-006A0 2010 C LEGEND 560 AS INDICATED BY:00 KEY NOTES 1 C3/C-006 L ROAD - PROFILEC 715 R400.00'REF. C-009R260.00'1 C3/C-006 * TRANSITION FROM STA. 14+84.83 TO STA. 15+40.98 * FROM STA. 15+89.78 TO STA. 19+25.00 A 2 /C -0 0 6 A A2/C-006A 1 ** MATCH EXISTING SURFACE # SEE PROFILE FOR ELEVATIONS PRC: POINT OF REVERSE CURVATURE ** # # # # # # # # # # # # ** ** ** ** ** ** D C B A 1 2 3 4 5 1 2 3 4 5 ISSUING OFFICE: NO DESCRIPTIONDATE PROJECT NO: KEY PLAN FRISCO 0172-16 CITY OF DENTON MSW LANDFILL CELL 3 LINER CONSTRUCTION AND 1527 SOUTH MAYHILL ROAD DENTON, TEXAS 76208 SITE IMPROVEMENTSPROF E SSIONA L E N G IN EERL I C E N S E D S T A T E OF TEXA S PARKHILL S M IT H & COOPER,I N C. F-560FRANK E. PUGSLEY 98460 02/16/2017 C-007 50 1000 LEGEND 560 PROPERTY LINE PERMIT BOUNDARY EXISTING CONTOURS PROPOSED CONTOURSA1/C-006REF C-006 OLD EDWARDS ROAD MAYHILL ROADCELL 2 (PREVIOUSLY LINED) CELL 3 (PREVIOUSLY LINED) EXISTING GROUND PROPOSED PRE-CAST SCREENING WALL ALIGNMENT PROPOSED BOTTOM OF WALL PROPOSED TOP OF WALL 1. WALL PROFILE IS FOR REPRESENTATIVE PURPOSES ONLY. FINAL WALL DESIGN AND LAYOUT SHALL BE IN ACCORDANCE WITH THE WALL PERFORMANCE AND DESIGN PARAMETERS NOTED ON THIS SHEET. THE MAXIMUM GAP BELOW WALL SHALL NOT EXCEED 8-INCHES. NOTES PERFORMANCE AND APPEARANCE DESIGN PARAMETERS 1. 2012 INTERNATIONAL BUILDING CODE 2. WIND LOADS A. ULTIMATE WIND SPEED 120 MPH B. WIND EXPOSURE CATEGORY C C. RISK CATEGORY I 3. WALL REQUIREMENTS A. WALL CONSTRUCTED OF PRECAST CONCRETE ELEMENTS B. MINIMUM CONCRETE STRENGTH (COLUMNS AND WALLS) I. 4,000 PSI 28-DAY COMPRESSIVE STRENGTH C. MINIMUM HEIGHT BETWEEN COLUMNS FROM GROUND – 8 FEET D. MAXIMUM HEIGHT BETWEEN COLUMNS FROM GROUND – 8 FEET 8 INCHES E. MINIMUM WALL THICKNESS BETWEEN COLUMN ELEMENTS – 3-INCHES F. MAXIMUM SPACING BETWEEN WALL COLUMNS – 10 FEET ON CENTER G. SPACE BETWEEN BOTTOM OF WALL AND GROUND BETWEEN COLUMNS I. MINIMUM – 4 INCHES II. MAXIMUM – 8 INCHES H. MINIMUM COLUMN SIZE – 12-INCH SQUARE I. COLUMN CAPS AT EACH COLUMN J. FINISH TEXTURE – STONE AS SELECTED BY THE OWNER K. COLOR – ONE BASE COLOR AND TWO ACCENT COLORS L. CONSTRUCT 2-FT WIDE, 4" THICK MOW STRIP CENTERED ON WALL WITH 2 - #3 CONTINUOUS REBAR. 4. MINIMUM FOUNDATION REQUIREMENTS AT EACH COLUMN A. 18-INCH DIAMETER PIER EXTENDING A MINIMUM OF 8 FEET INTO GROUND B. MINIMUM VERTICAL REINFORCING – 1% OF THE PIER AREA C. PIER DIAMETER SHALL BE SUFFICIENT SIZE IN ORDER TO BE LARGER THAN COLUMN ITS SUPPORTS D. ACTUAL DESIGN REQUIREMENTS TO BE CONFIRMED BY THE PROFESSIONAL ENGINEER OF RECORD PRIOR TO CONSTRUCTION, SITE SPECIFIC SHOP DRAWINGS AND STRUCTURAL CALCULATIONS SHALL BE SUBMITTED SEALED AND SIGNED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF TEXAS FOR REVIEW. 5. SAMPLES OF INTENDED WALL CONSTRUCTION INDICATING FINISH TEXTURE AND COLORS SHALL BE SUBMITTED FOR REVIEW AND APPROVAL. 6. BID PRICE SHALL INCLUDE ENGINEERING, DESIGN, SHOP DRAWINGS, REVISIONS TO SHOP DRAWINGS IF REQUIRED, DELIVERY, INSTALLATION OF FOUNDATIONS/COLUMNS/WALLS 0 2010 D C B A 1 2 3 4 5 1 2 3 4 5 ISSUING OFFICE: NO DESCRIPTIONDATE PROJECT NO: KEY PLAN FRISCO 0172-16 CITY OF DENTON MSW LANDFILL CELL 3 LINER CONSTRUCTION AND 1527 SOUTH MAYHILL ROAD DENTON, TEXAS 76208 SITE IMPROVEMENTSPROF E SSIONA L E N G IN EERL I C E N S E D S T A T E OF TEXA S PARKHILL S M IT H & COOPER,I N C. F-560FRANK E. PUGSLEY 98460 02/16/2017 C-008 50 1000 LEGEND 560 PROPERTY LINE PERMIT BOUNDARY EXISTING CONTOURS PROPOSED CONTOURS OLD EDWARDS ROAD CELL 4 (PREVIOUSLY LINED) EXISTING GROUND PROPOSED PRE-CAST SCREENING WALL ALIGNMENT PROPOSED BOTTOM OF WALL PROPOSED TOP OF WALLA1/C-0061. WALL PROFILE IS FOR REPRESENTATIVE PURPOSES ONLY. FINAL WALL DESIGN AND LAYOUT SHALL BE IN ACCORDANCE WITH THE WALL PERFORMANCE AND DESIGN PARAMETERS NOTED ON THIS SHEET. THE MAXIMUM GAP BELOW WALL SHALL NOT EXCEED 8-INCHES. NOTES 0 2010 PERFORMANCE AND APPEARANCE DESIGN PARAMETERS 1. 2012 INTERNATIONAL BUILDING CODE 2. WIND LOADS A. ULTIMATE WIND SPEED 120 MPH B. WIND EXPOSURE CATEGORY C C. RISK CATEGORY I 3. WALL REQUIREMENTS A. WALL CONSTRUCTED OF PRECAST CONCRETE ELEMENTS B. MINIMUM CONCRETE STRENGTH (COLUMNS AND WALLS) I. 4,000 PSI 28-DAY COMPRESSIVE STRENGTH C. MINIMUM HEIGHT BETWEEN COLUMNS FROM GROUND – 8 FEET D. MAXIMUM HEIGHT BETWEEN COLUMNS FROM GROUND – 8 FEET 8 INCHES E. MINIMUM WALL THICKNESS BETWEEN COLUMN ELEMENTS – 3-INCHES F. MAXIMUM SPACING BETWEEN WALL COLUMNS – 10 FEET ON CENTER G. SPACE BETWEEN BOTTOM OF WALL AND GROUND BETWEEN COLUMNS I. MINIMUM – 4 INCHES II. MAXIMUM – 8 INCHES H. MINIMUM COLUMN SIZE – 12-INCH SQUARE I. COLUMN CAPS AT EACH COLUMN J. FINISH TEXTURE – STONE AS SELECTED BY THE OWNER K. COLOR – ONE BASE COLOR AND TWO ACCENT COLORS L. CONSTRUCT 2-FT WIDE, 4" THICK MOW STRIP CENTERED ON WALL WITH 2 - #3 CONTINUOUS REBAR. 4. MINIMUM FOUNDATION REQUIREMENTS AT EACH COLUMN A. 18-INCH DIAMETER PIER EXTENDING A MINIMUM OF 8 FEET INTO GROUND B. MINIMUM VERTICAL REINFORCING – 1% OF THE PIER AREA C. PIER DIAMETER SHALL BE SUFFICIENT SIZE IN ORDER TO BE LARGER THAN COLUMN ITS SUPPORTS D. ACTUAL DESIGN REQUIREMENTS TO BE CONFIRMED BY THE PROFESSIONAL ENGINEER OF RECORD PRIOR TO CONSTRUCTION, SITE SPECIFIC SHOP DRAWINGS AND STRUCTURAL CALCULATIONS SHALL BE SUBMITTED SEALED AND SIGNED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF TEXAS FOR REVIEW. 5. SAMPLES OF INTENDED WALL CONSTRUCTION INDICATING FINISH TEXTURE AND COLORS SHALL BE SUBMITTED FOR REVIEW AND APPROVAL. 6. BID PRICE SHALL INCLUDE ENGINEERING, DESIGN, SHOP DRAWINGS, REVISIONS TO SHOP DRAWINGS IF REQUIRED, DELIVERY, INSTALLATION OF FOUNDATIONS/COLUMNS/WALLS 201 202 203 204 205 206 207 CONTROL POINT TABLE POINT # 201 202 203 204 205 206 207 NORTHING 7,116,556.23 7,116,595.37 7,116,676.63 7,116,173.69 7,116,194.13 7,116,421.24 7,116,446.94 EASTING 2,402,973.49 2,403,065.51 2,403,123.78 2,402,745.12 2,402,843.01 2,402,947.53 2,402,990.42 D C B A 1 2 3 4 5 1 2 3 4 5 ISSUING OFFICE: NO DESCRIPTIONDATE PROJECT NO: KEY PLAN FRISCO 0172-16 CITY OF DENTON MSW LANDFILL CELL 3 LINER CONSTRUCTION AND 1527 SOUTH MAYHILL ROAD DENTON, TEXAS 76208 SITE IMPROVEMENTSPROF E SSIONA L E N G IN EERL I C E N S E D S T A T E OF TEXA S PARKHILL S M IT H & COOPER,I N C. F-560FRANK E. PUGSLEY 98460 02/16/2017 C-009 50 1000 A1/C-009 A1/C-009 LEGEND PROPERTY LINE PERMIT BOUNDARY EXISTING FENCE EXISTING SEWER LINE EXISTING VEGETATION EXISTING POST/BOLLARD EXISTING UTILITY MANHOLE EXISTING GROUND TAMPED BACKFILL EXISTING GROUND 50' O.C.25'8' - 10'VARIES VARIESVARIES25'8' - 10'TREATED UTILITY POLE 5/8" GALV. STEEL EYEBOLTS 5/16" GALV. STEEL MILSPEC CABLE VINYL COATED TO 3/8" NETTEXX GF-X NETTING HELICAL/BUST OUT STYLE ANCHOR 3/8" GALV. STEEL MILSPEC CABLE POLY ROPE BORDER 3/8" GALV. STEEL SNAP HOOKS TAMPED BACKFILL YELLOW SAFETY COVER 3/8" GALV. STEEL MILSPEC CABLE NETTEXX GF-X NETTING TREATED UTILITY POLE (CLASS III) A1 A4A4/C-009REF. C-006A EXISTING SCALE HOUSE EXISTING OUTBOUND SCALE EXISTING INBOUND SCALES 1 1 ***CAUTION*** EXISTING ELECTRICAL STATION TO REMAIN PROPOSED SCALE SEE STRUCTURAL SHEETS FOR SCALE DESIGN 3 1 2 PROPOSED BY-PASS LANE SEE SHEET C-012 FOR PAVEMENT & GRADING PLAN EXISTING 12" PVC DRAIN LINE EXISTING 2" PVC REUSE WATER LINE EXISTING 8" REUSE WATER LINE MODULAR BUILDING EXISTING PROPANE TANK ON CONC PAD EXISTING DUMPSTERS ON CONC PAD EXISTING PROPANE-FED GENERATOR ON CONC PAD MODULAR BUILDING ***CAUTION*** EXISTING UNDERGROUND UTILITIES FIELD VERIFY LOCATION PRIOR TO CONSTRUCTION OR EXCAVATION 5 4 D C B A 1 2 3 4 5 1 2 3 4 5 ISSUING OFFICE: NO DESCRIPTIONDATE PROJECT NO: KEY PLAN FRISCO 0172-16 CITY OF DENTON MSW LANDFILL CELL 3 LINER CONSTRUCTION AND 1527 SOUTH MAYHILL ROAD DENTON, TEXAS 76208 SITE IMPROVEMENTSPROF E SSIONA L E N G IN EERL I C E N S E D S T A T E OF TEXA S PARKHILL S M IT H & COOPER,I N C. F-560FRANK E. PUGSLEY 98460 02/16/2017 C-010 20 400 1 INSTALL PIPE FENCING (±116 LF TOTAL) 2 3 ADJUST TO GRADE/ADD CLEANOUT TO DRAIN VENT KEY NOTES REPLACE CONCRETE PAVEMENT PER DETAIL D4 SHEET C-016 FOLLOWING SCALE INSTALLATION 25'-4"± x 40'-0" HIP SHADE STRUCTURE, MINIMUM 15-FT ENTRY HEIGHT. REF. C-016 28'-0"± x 40'-0" HIP SHADE STRUCTURE, MINIMUM 15-FT ENTRY HEIGHT. REF. C-016 EXISTING FENCE EXISTING VEGETATION EXISTING POST/BOLLARD EXISTING UTILITY MANHOLE NEW SCREEN FENCE POST NEW SWALE CENTERLINE AND DIRECTION OF FLOW FINISH GRADE CONTOUR FINISH GRADE SPOT ELEVATION LEGEND 601.88 FL. 602.75 PROPOSED PIPE FENCING CONCRETE PAVEMENT EXISTING FIRE HYDRANT EXISTING SEWER LINE WITH MANHOLE EXISTING WATER LINE WITH VALVE NEW WATER LINE WITH VALVE PERMIT BOUNDARY NOTES 1. SEE SHEET C-013 FOR THE TRUCK SCALE DEMOLITION PLAN 2. SHADE MANUFACTURER SHALL VISIT THE SITE PRIOR TO FABRICATION EXISTING STORM DRAIN LINE EXISTING POWER POLE EXISTING OVERHEAD ELECTRIC EXISTING RAW WATER LINE EXISTING SIGN EXISTING LIGHT POLE 4 5 EXISTING SCALE HOUSE EXISTING OUTBOUND SCALE EXISTING INBOUND SCALES ***CAUTION*** EXISTING ELECTRICAL STATION TO REMAIN 1 PROPOSED BY-PASS LANE SEE SHEET C-012 FOR PAVEMENT & GRADING PLAN EXISTING 12" PVC DRAIN LINE EXISTING 2" PVC REUSE WATER LINE EXISTING 8" REUSE WATER LINE MODULAR BUILDING EXISTING PROPANE TANK ON CONC PAD EXISTING DUMPSTERS ON CONC PAD EXISTING PROPANE-FED GENERATOR ON CONC PAD MODULAR BUILDING ***CAUTION*** EXISTING UNDERGROUND UTILITIES FIELD VERIFY LOCATION PRIOR TO CONSTRUCTION OR EXCAVATION 1 1 2 3 4 5 66 7 2 5 8 D C B A 1 2 3 4 5 1 2 3 4 5 ISSUING OFFICE: NO DESCRIPTIONDATE PROJECT NO: KEY PLAN FRISCO 0172-16 CITY OF DENTON MSW LANDFILL CELL 3 LINER CONSTRUCTION AND 1527 SOUTH MAYHILL ROAD DENTON, TEXAS 76208 SITE IMPROVEMENTSPROF E SSIONA L E N G IN EERL I C E N S E D S T A T E OF TEXA S PARKHILL S M IT H & COOPER,I N C. F-560FRANK E. PUGSLEY 98460 02/16/2017 C-011 20 400 1 KEY NOTES 1 SAWCUT & REMOVE 24" EXISTING PAVEMENT (±152 LF TOTAL) 2 SAWCUT & REMOVE EXISTING SIDEWALK (±64 SF) 3 REMOVE EXISTING PIPE FENCING (±170 LF) 4 REMOVE & RELOCATE EXISTING SIGN DEMOLITION NOTES 5 SAWCUT & REMOVE EXISTING CONCRETE PAVEMENT (±245 SF) 6 REMOVE & RELOCATE EXISTING LIGHT POLE 7 CUT & PLUG EXISTING 2" PVC REUSE WATER LINE EXISTING FENCE EXISTING VEGETATION EXISTING POST/BOLLARD EXISTING UTILITY MANHOLE NEW SCREEN FENCE POST NEW SWALE CENTERLINE AND DIRECTION OF FLOW FINISH GRADE CONTOUR FINISH GRADE SPOT ELEVATION LEGEND 601.88 FL. 602.75 PROPOSED PIPE FENCING CONCRETE PAVEMENT EXISTING FIRE HYDRANT EXISTING SEWER LINE WITH MANHOLE EXISTING WATER LINE WITH VALVE NEW WATER LINE WITH VALVE PERMIT BOUNDARY EXISTING STORM DRAIN LINE EXISTING POWER POLE EXISTING OVERHEAD ELECTRIC EXISTING RAW WATER LINE EXISTING SIGN EXISTING LIGHT POLE FUNCTIONALITY OF THE EXISTING OUTBOUND SCALE SHALL BE PRESERVED THROUGHOUT CONSTRUCTION 8 SAWCUT & REMOVE EXISTING CONCRETE PAVEMENT (±901 SF) EXCAVATE PIT FOR PROPOSED SCALE PER REQUIRED DEPTH SHOWN ON THE STRUCTURAL SHEETS C-013 D C B A 1 2 3 4 5 1 2 3 4 5 ISSUING OFFICE: NO DESCRIPTIONDATE PROJECT NO: KEY PLAN FRISCO 0172-16 CITY OF DENTON MSW LANDFILL CELL 3 LINER CONSTRUCTION AND 1527 SOUTH MAYHILL ROAD DENTON, TEXAS 76208 SITE IMPROVEMENTSPROF E SSIONA L E N G IN EERL I C E N S E D S T A T E OF TEXA S PARKHILL S M IT H & COOPER,I N C. F-560FRANK E. PUGSLEY 98460 02/16/2017 EXISTING GROUND CONTOURS AND ELEVATION EXISTING FENCE EXISTING VEGETATION EXISTING POST/BOLLARD EXISTING UTILITY MANHOLE NEW SCREEN FENCE POST NEW SWALE CENTERLINE AND DIRECTION OF FLOW FINISH GRADE CONTOUR FINISH GRADE SPOT ELEVATION LEGEND N 0 105 601.88 FL. 602.75 1 NOTES 1. REMOVE AND DISPOSE OF EXISTING TREE. AS INDICATED BY:00 KEY NOTES 1. 6" HDPE PIPE 2. 6" VALVE 3. 6"X4" REDUCER 4. 4" HDPE PIPE 5. 4" VALVE 6. 4" CROSS 7. 4" BASKET STRAINER 8. 4" TEE 9. 3 - VARIABLE DRIVE PUMPS 10. PUMP CONTROL PANEL 11. ELECTRICAL PANEL 12. 4" 90° BEND 13. 10'X10' PREBUILT METAL BUILDING 14. 6" 90° BEND 15. 6" 45° BEND 16. PIPE SUPPORT 17. FILL LEVEL INDICATOR 18. HEATER 01 02 03 04 05 06 07 08 05 09 0305 09 09 10 TANK TANK 6" CONCRETE FOUNDATION WITH #4's @ 18" E.W. 06 09 10 12 05 C4 SECTION 3/8"=1'-0" B4 PLAN 3/8"=1'-0" 11 13 13 B4/C-013 C4/C-013CONNECT TO EXISTING 6" ELR FORCEMAIN 15 CONNECT TO EXISTING 6" ELR FORCEMAIN 14 14 2 12 05 16 (TYP.) 16 (TYP.) 08 12 05 05 TANK FOUNDATION (ENGINEERED BY TANK MANUFACTURER) 17 17 6" CONCRETE FOUNDATION WITH #4's @ 18" E.W. TANK FOUNDATION (ENGINEERED BY TANK MANUFACTURER) EXPANSION JOINT 17 18 15 07 14 14 14 2 1 3 4 5 6 7 8 9 10 10 11 12'12'12' 12 12 12 13 14 D C B A 1 2 3 4 5 1 2 3 4 5 ISSUING OFFICE: NO DESCRIPTIONDATE PROJECT NO: KEY PLAN FRISCO 0172-16 CITY OF DENTON MSW LANDFILL CELL 3 LINER CONSTRUCTION AND 1527 SOUTH MAYHILL ROAD DENTON, TEXAS 76208 SITE IMPROVEMENTSPROF E SSIONA L E N G IN EERL I C E N S E D S T A T E OF TEXA S PARKHILL S M IT H & COOPER,I N C. F-560FRANK E. PUGSLEY 98460 02/16/2017 C-014 20 400 LEGEND 560 PERMIT BOUNDARY EXISTING CONTOURS PROPOSED CONTOURS 1 EASI-SET RESTROOM PER SHEET C-015 2 VENDING AREA 3 KEY NOTES 265 SF 5" CONCRETE SIDEWALK 4 STANDARD 6' PICNIC TABLE 5 20' X 20' SHADE STRUCTURE PER C-016 6 TAP INTO EXISTING & INSTALL 43 LF 4" SANITARY SEWER SERVICE LINE 7 TAP INTO EXISTING & INSTALL 14 LF 3/4" WATER SERVICE LINE & METER8 REST AREA ACCESS DRIVE9 PARKING LANE10 ACCESS DRIVING LANE11 INSTALL SANITARY SEWER CLEANOUT MATCH EXISTING GRADES12 CONCRETE ENCASE, 20-LF CENTERED OVER EXISTING WATER LINE13 REFER E-102 FOR SERVICE CONNECTION TO RESTROOM14 D C B A 1 2 3 4 5 1 2 3 4 5 ISSUING OFFICE: NO DESCRIPTIONDATE PROJECT NO: KEY PLAN FRISCO 0172-16 CITY OF DENTON MSW LANDFILL CELL 3 LINER CONSTRUCTION AND 1527 SOUTH MAYHILL ROAD DENTON, TEXAS 76208 SITE IMPROVEMENTSPROF E SSIONA L E N G IN EERL I C E N S E D S T A T E OF TEXA S PARKHILL S M IT H & COOPER,I N C. F-560FRANK E. PUGSLEY 98460 02/16/2017 C-015 1 ROOFLINE WILL BE EXTENDED TO INCLUDE VENDING AREA 2 SLAB WILL BE EXTENDED TO INCLUDE VENDING AREA 3 KEY NOTES VENDING AREA FOR DRINK/SNACK MACHINES 1 GENERAL NOTES 1. PRECAST CONCRETE BUILDING TO BE DELIVERED FULLY EQUIPPED WITH FIXTURES, FORM LINER FINISHED, LIGHTS (60 AMP ELECTRICAL PANEL), FANS, DOORS, AND WINDOWS. 2. BUILDING MANUFACTURER TO DELIVER AND SET BUILDING ON-SITE. CRANE ACCESS TO WITHIN 25' OF BUILDING LOCATION REQUIRED. 3. CONTRACTOR SHALL PROVIDE WATER & SEWER STUB-OUTS AND GRANULAR SUB-BASE FOR THE RESTROOM BUILDING. 3 2 1 3 2 1 2 3 D C B A 1 2 3 4 5 1 2 3 4 5 ISSUING OFFICE: NO DESCRIPTIONDATE PROJECT NO: KEY PLAN FRISCO 0172-16 CITY OF DENTON MSW LANDFILL CELL 3 LINER CONSTRUCTION AND 1527 SOUTH MAYHILL ROAD DENTON, TEXAS 76208 SITE IMPROVEMENTSPROF E SSIONA L E N G IN EERL I C E N S E D S T A T E OF TEXA S PARKHILL S M IT H & COOPER,I N C. F-560FRANK E. PUGSLEY 98460 02/16/2017 C-016 DETAILS C-017 D C B A 1 2 3 4 5 1 2 3 4 5 ISSUING OFFICE: NO DESCRIPTIONDATE PROJECT NO: KEY PLAN FRISCO 0172-16 CITY OF DENTON MSW LANDFILL CELL 3 LINER CONSTRUCTION AND 1527 SOUTH MAYHILL ROAD DENTON, TEXAS 76208 SITE IMPROVEMENTSPROF E SSIONA L E N G IN EERL I C E N S E D S T A T E OF TEXA S PARKHILL S M IT H & COOPER,I N C. F-560FRANK E. PUGSLEY 98460 02/16/2017