Loading...
6518 - Underground Electric Service Installation, 1.Pricing SheetExhibit 1 RFP 6518 - Pricing Sheet for UNDERGROUND ELECTRIC SERVICE INSTALLATION The respondent shall complete the following section, which directly corresponds to the specifications. The contractor shall not make changes to this format. Product Proposal Pricing (PRICING SHALL INCLUDE ALL COSTS TO DELIVER GOODS AS SPECIFIED F.O.B DESTINATION): RFP Item # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 Payment Term Discounts Payment terms for the City of Denton are typically 30 days. Please indicate the additional discount extended to each monthly invoice that is paid within the time period indicated below. DME Item # D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 D13 D14 D15 D16 D17 D18 D19 D20 D21 D22 D23 D24 D25 D26 D27 D28 D29 D30 D31 D32 D33 CT1 CT2 CT3 CT4 CT5 CT6 CT7 CT8 CT9 CT10 CT11 CT12 CT13 CT14 CT15 CB1 CB2 CB3 CB4 CB5 CB6 CB7 CB8 CB9 CB10 CB11 CB12 CB13 CB14 CB15 CB16 CB17 CB18 CB19 CB20 CB21 CB22 CB23 CB24 CB25 CB26 CB27 CI1 CI2 CI3 CI4 CI5 CI6 CI7 CI8 CI9 CI10 CI11 CI12 CI13 CI14 CI15 CI16 CI17 T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 T12 T13 T14 T15 T16 T17 T18 T19 T20 T21 T22 T23 T24 T25 T26 T27 T28 T29 A1 A2 A3 V1 V2 V3 V4 V5 V6 V7 V8 V9 V10 V11 V12 V13 V14 V15 V16 V17 V18 V19 V20 V21 V22 V23 V24 V25 P1 P2 P3 E1 E2 E3A E3B E3C E4 E5 E6 E7 E8 SL1 SL2 SL3 SL4 S1 S2 S3 S4 M1 M2 M3 M4 M5 M6 M7 M8 M8 M10 M11 M12 M13 M14 EST. ANNUAL QTY 2000 5000 5000 25000 25000 15000 1000 1000 1000 10000 10000 5000 1000 1000 1000 1000 1000 1000 2000 1000 1000 500 1000 1000 1000 1000 500 2500 2500 1000 500 500 1000 1000 5000 5000 100 2500 25 50 50 1 50 10 10 1 10 10 1000 100 25000 2000 20000 1000 100 100 20000 20000 20000 12000 5000 1000 500 1000 1000 5 1000 1000 50 50 1 200 200 100 100 2500 5000 70000 10000 100000 500 500 25000 1000 10000 1000 15000 150000 2000 700 400 40 1000 20 500 30 60 300 150 4 50 10 5 5 1 1 25 5 30 100 210 50 50 5 25 25 30 150 30 60 200 300 90 30 4 4 5 10 120 5 30 5 12 100 15 25 10 10 6 6 6 6 6 6 6 6 150 75 50 350 50 10 600 350 30 20 10 75 15 20 5 5 300 100 25 50 50000 50 30 3000 250 300 500 500 300 25 10 35 25 10 35 20 10 30 UOM Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Cy Ft LF LF LF LF Ft Ft Ft Ft Ft Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ea Set Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ft Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ea Ft Ea Trip Ft HR HR HR HR HR Ea Ea Ea Ea Ea Ea Ea Ea Ea EA EA Respondent's Business Name: Principal Place of Business (City and State) Description 2 Excavation and Backfill Trench with Trencher 6" wide by 30" deep Trench with Trencher 6" wide by 48" deep Trench with Trencher 6" wide by 60" deep Trench with Backhoe 18" wide 48" deep Trench with Backhoe 18" wide 60" deep Trench with Backhoe 18" wide 72" deep Trench with Backhoe 18" wide 84" deep Trench with Backhoe 18" wide 96" deep Trench with Backhoe 24" wide 48" deep Trench with Backhoe 24" wide 60" deep Trench with Backhoe 24" wide 72" deep Trench with Backhoe 24" wide 84" deep Trench with Backhoe 24" wide 96" deep Trench with Backhoe 36" wide 48" deep Trench with Backhoe 36" wide 60" deep Trench with Backhoe 36" wide 72" deep Trench with Backhoe 36" wide 84" deep Trench with Backhoe 36" wide 96" deep Special trencher for trenching in rock, 6" width Rock Adder, Backhoe 18" Width, Cutting & Jack Hammer Rock Adder, Backhoe 24" Width, Cutting & Jack Hammer Rock Adder, Backhoe 36" Width, Cutting & Jack Hammer Rock Adder, Backhoe 18" Width, Large Rock Quantity Rock Adder, Backhoe 24" Width, Large Rock Quantity Rock Adder, Backhoe 36" Width, Large Rock Quantity Hand Digging 12" x 30" deep or less Hand Digging 12" x 31" - 48" deep Concrete Backfill of Trench Excavated by Backhoe Mechanical Tamping of Trench Excavated by Backhoe 2" - 4" Thick Asphalt Saw Cut 1" - 6" Concrete Saw Cut 8"+ Thick Concrete Saw Cut 4"+ Asphalt and/or Concrete Saw Cut Conduit Installation in 6" Wide Trench Conduit 1" PVC Conduit 2" PVC Conduit 2 & 1/2 " PVC Conduit 3" PVC Conduit 4" PVC Conduit 1" PVC 90 degree sweep Conduit 2" PVC 90 degree sweep Conduit 2 & 1/2 " PVC 90 degree sweep Conduit 3" PVC 90 degree sweep Conduit 4" PVC 90 degree sweep Conduit 2" PVC 45 degree sweep Conduit 2 & 1/2 " PVC 45 degree sweep Conduit 3" PVC 45 degree sweep Conduit 4" PVC 45 degree sweep Conduit 4" PVC 22 & 1/2 degree sweep Multiple Conduit Installations in 18" to 36" Trench Conduit 1" PVC Additional 1" PVC Conduit in Trench Conduit 2" PVC Additional 2" PVC Conduit in Trench Conduit 2 & 1/2 " PVC Additional 2 & 1/2" PVC Conduit in Trench Conduit 3" PVC Additional 3" PVC Conduit in Trench Conduit 4" PVC Additional 4" PVC Conduit in Trench Conduit 6" PVC Additional 6" PVC Conduit in Trench Bank of two 6", two 4", two 2", and two 1" installed in conduit spacers Bank of three 6", three 4", three 2", and two 1" installed in conduit spacers Conduit 1" PVC 90 degree sweep Conduit 2" PVC 90 degree sweep Conduit 2 & 1/2 " PVC 90 degree sweep Conduit 3" PVC 90 degree sweep Conduit 4" PVC 90 degree sweep Conduit 6" PVC 90 degree sweep Multiple Conduit Installations in 18" to 36" Trench (Continued) Conduit 2" PVC 45 degree sweep Conduit 2 & 1/2 " PVC 45 degree sweep Conduit 3" PVC 45 degree sweep Conduit 4" PVC 45 degree sweep Conduit 6" PVC 45 degree sweep Conduit 4" PVC 22 & 1/2 degree sweep Conduit 6" PVC 22 & 1/2 degree sweep Primary and Secondary Conductor Installation Cable, Cu UF SOL, 12/2 awg Secondary Cable, Al #6 Duplex Cable, Al 4/0 4/0 2/0 Secondary Cable, 350, 350, 4/0 Secondary Cable, # 2 Al 15 kV Single Phase Pull Cable, # 1/0 Al 15 kV Single Phase Pull Cable, #4/0 Al 15 kV Single Phase Pull Cable, #2 Al 15 kV Three Phase Pull Cable, #1/0 Al 15 kV Three Phase Pull Cable, # 4/0 Al 15 kV Three Phase Pull Cable, 250 MCM Cu 15 kV Three Phase Pull (Includes 4/0 bare neutral) Cable, 500 MCM Cu 15 kV Three Phase Pull (Includes 4/0 bare neutral) Cable, 750 MCM Cu 15 kV Three Phase Pull (Includes 4/0 bare neutral) Cable, 8 Triplex Cu Install Fault Indicator Single Phase Install Fault Indicator Three Phase Multiple Duct Bank Tagging of Conductors in Multiple Duct Banks (individual conduits and cables shall be included in base bid) Terminations Elbow, Loadbreak #2 AL 220 mil 15 kV Elbow, Loadbreak #1/0 AL 220 mil 15 kV Elbow, Loadbreak #4/0 AL 220 mil 15 kV Elbow, T Nonloadbreak 250 MCM or 4/0 15 kV Elbow, T Nonloadbreak 500 MCM 15 kV Elbow, T Nonloadbreak 750 MCM 15 kV Termination Rack / Utility Pole single phase # 2 Termination Rack / Utility Pole vee phase # 2 Termination Rack / Utility Pole 3 phase # 2 Termination Rack / Utility Pole single phase #1/0 Termination Rack on a Utility Pole vee phase # 1/0 Termination Rack on a Utility Pole 3 phase # 1/0 Termination Rack / Utility Pole single phase #4/0 Termination Rack on a Utility Pole vee phase # 4/0 Termination Rack on a Utility Pole 3 phase # 4/0 Termination Rack on a Utility Pole 3 phase 250MCM Termination Rack on a Utility Pole 3 phase 500 MCM Termination Rack on a Utility Pole 3 phase 750MCM 600 - 200 AMP Plug Adapter Insulated Plugs/Deadend Plugs Splice, #2 AL 220 mil 15 kV Splice, #1/0 AL 220 mil 15 kV Splice, #4/0 AL 220 mil 15 kV Splice, 250 MCM or 4/0 15 kV Splice, 500 MCM 15 kV Splice, 750 MCM 15 kV Indoor Termination 250MCM Indoor Termination 500MCM Indoor Termination 750MCM Arresters Arrester Elbow, 10 kV Arrester, Bushing 10 kV Arrester, Parking Stand 10 kV Manholes and Vaults 2 Way Manhole 12' X 12' X 9' with 5' of Cover 4 Way Manhole 12' X 12' X 9' with 5' of Cover 3 Way Manhole 12' X 10' X 9' with 5' of Cover Additional foot of cover for 4 Way or 3 Way to 10' Polymer Concrete Vault 4'W X 5'D x 8'L Surface Mount Polymer Concrete Vault 4'W X 5'D x 6'L Surface Mount Polymer Concrete Vault 3'W X 5'D x 5'L Surface Mount Polymer Concrete Vault 4'W X 4'D x 4'L Surface Mount Polymer Concrete Box 13"W X 18"D x 24"L Surface Mount Polymer Concrete Box 12"W X 12"D x 12"L Surface Mount Fiberglass Sleeve, Pri. Connection Cabinet 1 Phase Fiberglass Sleeve, Pri. Connection Cabinet 3 Phase Excavation to Access side of a Manhole Excavation to Access side of a Vault 6" Conduit Entry into Manhole 4" Conduit Entry into Manhole 2 1/2" Conduit Entry into Manhole 2" Conduit Entry into Manhole 6" Conduit Entry into Vault 4" Conduit Entry into Vault 2 1/2" Conduit Entry into Vault 2" Conduit Entry into Vault Installation of 4' x 6' Concrete Pull Box Installation of 3' x 5' Concrete Pull Box Installation of Fiber Communications Box Foundations Transformer Pad 48" X 54" Fibercrete Switch Gear Pad 7' x 7' x 3' Transformer Pad 83" X 83" Old Castle Equipment Secondary Connection Pedestal Single Phase Transformer on Pad Three Phase Transformer on Pad up to 500KVA Three Phase Transformer on Pad above 500KVA up to 1500KVA Three Phase Transformer on Pad above 1500KVA Switch Gear on Pad - (PME Gear) Primary 1 Phase Sectionalizing Pedestal on Sleeve Primary 3 Phase Sectionalizing Pedestal on Sleeve Fused Cabinet Fused Cabinet Sleeve Other 20 Ft Concrete Pole and Street Light, 976 pounds 35 Ft Concrete Pole and Street Light 1,750 pounds 45 Ft Fiberglass Pole and Street Light Streetlight Poles with either bases or anchor cages on streetlights Service Installation Install 2.5" conduit with underground secondary conductors and warning tape. Secondary Riser Trip charge for additional trips after initial trip Bore for service installations (Residential) Hourly Three man crew to perform small projects Two man crew and backhoe to perform small projects Three man crew and backhoe to perform medium projects Four man crew and backhoe to perform large projects Dump truck used on projects where all excavated material is hauled off Large Track Hoe per day Large Track Hoe per week Delivery & Pickup of Large Track Hoe Aluminum Trench Box per day Aluminum Trench Box per week Delivery & Pickup of Aluminum Trench Box Steel Trench Box 8'Hx16'L per day Steel Trench Box 8'Hx16'L per week Delivery & Pickup of Steel 8'Hx16'L Trench Box Total Cost of Services (Annual) Number of Licensed Utility/Class A Journeyman available to DME Number of Crews Available to DME at one time Payment Terms Invoice Paid in 20 days Invoice Paid in 15 days Invoice Paid in 10 days *NOTE: EMAIL THIS EXHIBIT 1 AS AN EXCEL FILE TO EBIDS@CITYOFDENTON.COM Unit Price Additional Discount % Extended Price 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0