Loading...
6516 - Underground Directional Boring Services, 1.Pricing SheetExhibit 1 RFP 6516 Pricing Sheet for DIRECTIONAL BORING SERVICES FOR THE CITY OF DENTON The respondent shall complete the following section, which directly corresponds to the specifications. The contractor shall not make changes to this format. Services Proposal Pricing: ITEM SECTION I – DIRECTIONAL BORE WITH NO CASING – Contractor is to install conduit lines provided by the City. Pit excavation and backfill is to be included. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 SECTION II: DIRECTIONAL BORES WITH STEEL CASING AND CONDUIT LINE(S) INSTALLED. Price includes all costs required per specifications excluding steel casing and conduit line costs. Pit excavation and backfill to be included. Note: Pricing shall be by steel casing size. The contractor shall determine bore size needed. Steel casing cost will be determined by adding the appropriate line item from Section III. 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 SECTION III: STEEL CASING TO BE SUPPLIED BY CONTRACTOR 41 42 43 44 45 46 47 48 49 50 51 52 SECTION IV: BORES WITH STEEL CASING ONLY INSTALLED. Price includes all costs required per specifications excluding steel casing costs. Pit excavation and backfill to be included. 53 54 55 56 57 58 59 60 61 62 SECTION V: DIRECTIONAL BORE (NO STEEL CASING) Contractor is to install conduit provided by the City. PIT EXCAVATION/BACKFILL SHALL NOT BE INCLUDED IN UNIT PRICING. In the event that pit excavation/backfill is required, Section VI includes separate pricing for these items. SEE SPECIAL EXCEPTIONS FOR THIS SECTION IN THE SPECIFICATIONS (EXHIBIT 2) 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 SECTION VI: MISCELLANEOUS 81 82 83 84 85 86 87 * Per TxDOT standards 88 89 QTY 20000 2000 10000 1000 5000 400 4000 400 4000 400 2000 500 2000 500 2000 500 2000 500 2000 500 2000 500 2000 200 1000 100 2000 200 300 100 300 100 300 100 300 100 300 100 300 100 500 500 500 500 500 500 500 500 500 500 500 500 2000 200 1000 100 2000 200 300 100 300 100 3500 1000 15000 7500 1500 750 1500 750 1500 750 1500 750 1500 750 1500 750 1500 750 As needed As needed As needed As needed As needed As needed As needed UOM FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT FT EA LS SY FT EA HR LS *NOTE: PLEASE EMAIL THIS EXHIBIT 1 AS AN EXCEL FILE TO EBIDS@CITYOFDENTON.COM ID DBW1 DBW2 DBW3 DBW4 DBW5 DBW6 DBW7 DBW8 DBW9 DBW10 DBW11 DBW12 DBW13 DBW14 DBW15 DBW16 DBW17 DBW18 DBW19 DBW20 DBW21 DBW22 DBSC1 DBSC2 DBSC3 DBSC4 DBSC5 DBSC6 DBSC7 DBSC8 DBSC9 DBSC10 DBSC11 DBSC12 DBSC13 DBSC14 DBSC15 DBSC16 DBSC17 DBSC18 SC4 SC6 SC8 SC10 SC12 SC14 SC16 SC18 SC20 SC24 SC30 SC36 DBS1 DBS2 DBS3 DBS4 DBS5 DBS6 DBS7 DBS8 DBS9 DBS10 DB1 DB2 DB3 DB4 DB5 DB6 DB7 DB8 DB9 DB10 DB11 DB12 DB13 DB14 DB15 DB16 DB17 DB18 M1 M2 M3 M4 M5 M6 M7 EA EA Respondent's Business Name Principal Place of Business (City and State) Type of Service Requested Bore in Dirt with 2" or 2.5" Conduit Line installed Bore in Rock with 2" or 2.5" Conduit Line installed Bore in Dirt with 4" Conduit Line installed Bore in Rock with 4" Conduit Line installed Bore in Dirt with 6" Conduit Line installed Bore in Rock with 6" Conduit Line installed 8" Diameter Bore in Dirt with Conduit Line(s) installed 8" Diameter Bore in Rock with Conduit Line(s) installed 10" Diameter Bore in Dirt with Conduit Line(s) installed 10" Diameter Bore in Rock with Conduit Line(s) installed 12" Diameter Bore in Dirt with Conduit Line(s) installed 12" Diameter Bore in Rock with Conduit Line(s) installed 14" Diameter Bore in Dirt with Conduit Line(s) installed 14" Diameter Bore in Rock with Conduit Line(s) installed 16" Diameter Bore in Dirt with Conduit Line(s) installed 16" Diameter Bore in Rock with Conduit Line(s) installed 18" Diameter Bore in Dirt with Conduit Line(s) installed 18" Diameter Bore in Rock with Conduit Line(s) installed 20" Diameter Bore in Dirt with Conduit Line(s) installed 20" Diameter Bore in Rock with Conduit Line(s) installed 24" Diameter Bore in Dirt with Conduit Line(s) installed 24" Diameter Bore in Rock with Conduit Line(s) installed Bore in Dirt for 6" diameter steel casing with Conduit Line(s) installed in Steel Casing Bore in Rock for 6" diameter steel casing with Conduit Line(s) installed in Steel Casing Bore in Dirt for 8" diameter steel casing with Conduit Line(s) installed in Steel Casing Bore in Rock for 8" diameter steel casing with Conduit Line(s) installed in Steel Casing Bore in Dirt for 10" diameter steel casing with Conduit Line(s) installed in Steel Casing Bore in Rock for 10" diameter steel casing with Conduit Line(s) installed in Steel Casing Bore in Dirt for 12" diameter steel casing with Conduit Line(s) installed in Steel Casing Bore in Rock for 12" diameter steel casing with Conduit Line(s) installed in Steel Casing Bore in Dirt for 14" diameter steel casing with Conduit Line(s) installed in Steel Casing Bore in Rock for 14" diameter steel casing with Conduit Line(s) installed in Steel Casing Bore in Dirt for 16" diameter steel casing with Conduit Line(s) installed in Steel Casing Bore in Rock for 16" diameter steel casing with Conduit Line(s) installed in Steel Casing Bore in Dirt for 18" diameter steel casing with Conduit Line(s) installed in Steel Casing Bore in Rock for 18" diameter steel casing with Conduit Line(s) installed in Steel Casing Bore in Dirt for 20" diameter steel casing with Conduit Line(s) installed in Steel Casing Bore in Rock for 20" diameter steel casing with Conduit Line(s) installed in Steel Casing Bore in Dirt for 24" diameter steel casing with Conduit Line(s) installed in Steel Casing Bore in Rock for 24" diameter steel casing with Conduit Line(s) installed in Steel Casing 4" Diameter steel casing with 0.2500" minimum thickness 6" Diameter steel casing with 0.2500" minimum thickness 8" Diameter steel casing with 0.2500" minimum thickness 10" Diameter steel casing with 0.2500"' minimum thickness 12" Diameter steel casing with 0.2500" minimum thickness 14" Diameter steel casing with 0.3125" minimum thickness 16" Diameter steel casing with 0.3125" minimum thickness 18" Diameter steel casing with 0.3125" minimum thickness 20" Diameter steel casing with 0..3750" minimum thickness 24" Diameter steel casing with 0.4375" minimum thickness 30" Diameter steel casing with 0.5000" minimum thickness 36" Diameter steel casing with 0.5625" minimum thickness Bore in Dirt for 4" diameter steel casing installed in Steel Casing Bore in Rock for 4" diameter steel casing installed in Steel Casing Bore in Dirt for 6" diameter steel casing installed in Steel Casing Bore in Rock for 6" diameter steel casing installed in Steel Casing Bore in Dirt for 8" diameter steel casing installed in Steel Casing Bore in Rock for 8" diameter steel casing installed in Steel Casing Bore in Dirt for 10" diameter steel casing installed in Steel Casing Bore in Rock for 10" diameter steel casing installed in Steel Casing Bore in Dirt for 12" diameter steel casing installed in Steel Casing Bore in Rock for 12" diameter steel casing installed in Steel Casing Bore in Dirt with 1" Line installed Bore in Rock with 1" Line installed 2" Diameter Bore in Dirt 2" Diameter Bore in Rock 4" Diameter Bore in Dirt 4" Diameter Bore in Rock 6" Diameter Bore in Dirt 6" Diameter Bore in Rock 8" Diameter Bore in Dirt 8" Diameter Bore in Rock 10" Diameter Bore in Dirt 10" Diameter Bore in Rock 12" Diameter Bore in Dirt 12" Diameter Bore in Rock 14" Diameter Bore in Dirt 14" Diameter Bore in Rock 16" Diameter Bore in Dirt 16" Diameter Bore in Rock Mobilization Fee for Bores less than 20 ft. in length. Barricades, Warning, and Detour Signage (per job) ADDER: Cleanup and Restoration (Section V only) ADDER: Excavation of Sending and Receiving Viewing Pit $________/ foot deep/ pit (Section V only) ADDER: Backfill of Viewing Pit (Section V only) ADDER: Hourly crew rate for waiting on pits to be excavated Payment and Performance Bonds for a single project exceeding $250,000 (100% of $250,000) Grand Total: Number of boring machines available to City of Denton at one time Number of Crews Available to City of Denton at one time Unit Price Extended Price 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0