6553-3 Phase Over Phase 138kV GOAB Switch - Tech SpecsIFB 6553– Exhibit 3 Page 1 of 5 IFB # 6553 EXHIBIT 3 Technical Specifications Phase Over Phase 138kV GOAB Switch A. PURPOSE The City of Denton is providing information that will allow prospective suppliers to prepare submissions to supply completely assembled and tested, phase over phase, 138kV, pole mounted, gang operated air break (GOAB) switches with interrupters and motor operators or hand crank operator, where applicable, in accordance with the technical requirement contained herein. A drawing showing the expected arrangement of the pole mounted switches is shown on page 5. Field service for installation support and a five year warranty are required. The switches are to be priced FOB to the Spencer Utility Site, 1701C Spencer Road, in Denton, Texas or to other substation sites in or near Denton as directed at the time of shipment. B. SUBMISSIONS Submissions shall be provided using the Exhibit 1, with supporting documentation as required. Additional information clarifying the supplier’s product may be attached to their submission. Pricing shall include all costs to deliver goods as specified in this specification. Any special fees or commissions, and all freight for delivery to the City of Denton must be included in the quoted price. Item pricing shall be mutually exclusive, thus the City of Denton reserves the right to choose the best valued item from different vendors. C. QUALITY CONTROL The manufacturer shall be responsible for the quality control of the manufacturing processes to assure that all requirements of these specifications are met. However, the City reserves the right to observe, to inspect and to require additional quality control investigations, either by its personnel or an independently employed quality control investigator, at any or all stages of fabrication at the manufacturer’s facilities. Failure to adequately maintain fabrication and quality of fabrication until completion shall be grounds for cancellation of the order or any part thereof. Field failure or field repairs required due to quality control failures or manufacturing procedures shall be the responsibility of the manufacturer. D. WRITTEN WARRANTY and GUARANTEES Written guarantees shall include any limitations as to the nature of failure or time limitations. The guarantee shall begin upon receipt of the accepted units, not on the date of manufacture. Guarantees shall indicate whether or not it is made on a full replacement basis or a prorated basis and if prorated then what are the terms. Manufacturer/supplier guarantees that the goods furnished under this specification are of high quality and agrees to replace any goods found to be defective IFB 6553– Exhibit 3 Page 2 of 5 during inspection, installation, or service for a minimum period of 60 months after unit is delivered to Denton. All replacements by the manufacturer/supplier shall be free of charge F.O.B. at the same delivery point called for in the original order. Replacements must be handled in a professional and timely manner and in no case shall a replacement unit take longer than 60 days to arrive in Denton after first being submitted for replacement. Respondent guarantees that all products quoted and furnished under this agreement will be accepted at any normally used United States approved repair and warranty shop should one be available for the manufacturer’s product quoted. The City of Denton will not accept a manufacturer’s product that was rejected or substandard and then sold to a broker for either resale or scrap that would not be fully warranted by the original manufacturer. The respondent must be an approved distributor by the manufacturer of these products, and is authorized to sell the products to the City of Denton. The respondent also guarantees that the City will be represented by the Manufacturer, should an issue arise, and that all manufacturer’s warranties will be in effect for the life of the contract. E. SPECIAL DELIVERY REQUIREMENTS 1. Shipment by open flatbed truck: Switches purchased under this agreement shall be shipped FOB Destination by open flatbed truck fully assembled and ready for installation. The owner will provide unloading and installation. 2. Delivery location: Switches shall be delivered to the Spencer Utility Site, 1701C Spencer Road, Denton, Texas, 76205 or to other DME substations. 3. Notice of factory shipments: The supplier shall provide notice when the products are shipped. The owner only has a forklift to unload the products. Contact Sam Bridges at (940) 390-6279 for notices of shipment. Secondary contact is Misty Willis at 940-597- 7912. Delivery of the products will be accepted only between the hours of 8:00 am and 3:00 pm Monday through Friday, excluding holidays. 4. Damaged or defective material or equipment: Freight that is obviously damaged on arrival will be refused. Any necessary action regarding replacement of materials or equipment delivered in unacceptable condition shall be the responsibility of the supplier. This includes concealed freight damage as well as items originally defective from the manufacturer. The supplier shall be fully responsible for detecting shipping damage as a part of field services and assembly and for initiating all action necessary for replacement or repair of such damage in a timely manner. IFB 6553– Exhibit 3 Page 3 of 5 F. TECHNICAL RESPONSIBILITIES AND REQUIREMENTS Switch Specifications Quantity 1 Configuration One-Way Orientation Staggered (Delta) Nominal Voltage 138 kV BIL Rating 650 kV Continuous Current Rating 3000 Amps at 30° Temp Rise Momentary Current Rating 100 kA Vacuum Interrupter Devices Included with Switch? Yes Insulators Included with Switch? Yes Insulator Strength High BIL Rating 650 kV Technical Reference Number TR-289 Pole Structure Pole Type Steel Guyed (G) / Self-Supporting (SS) SS Shield Wire? Yes Distribution Underbuilt? Yes Clearance Issues? No Pole Structure Furnished with Switch? No Operating Environment Location Denton, TX NESC Loading District Heavy Approximate Elevation 604 feet above sea level Subject to heavy airborne particulate? No Subject to salt-laden environment? No Optional Features Grounding Platforms Furnished 1 Tin-plated Terminal Pads Furnished? Yes Terminal Connectors Furnished? Yes Motor Operator Quantity 1 Batteries, Charger and Battery Test? Yes Motor Control Voltage 24 VDC Customer Supplied Voltage 120 VAC Torque 20,000 inch/lbs. Operating Speed 3-5 seconds IFB 6553– Exhibit 3 Page 4 of 5 Switches shall be factory pre-assembled and adjusted to the maximum extent compatible with shipping limitations. RTU and communication devices will not be located within the motor operator enclosure. RTU and communication devices will be provided and installed by the Owner. The manufacturer shall include a price for onsite field installation assistance for final switch adjustment. The manufacturer shall provide a five year warranty on all parts along with the on-site installation assistance for each switch. The Owner will provide the steel pole and installation of the pole. G. ACCEPTABLE MANUFACTURERS DME will only accept submissions from specific manufacturers listed in the approved manufacturers list below. 1. SEECO 2. TURNER 3. SOUTHERN STATES The City has implemented a pre-approval process for substitution commodities and services. The commodity approval form can be obtained via email (laura.hermosillo@cityofdenton.com). Supporting documentation or samples must be submitted for review by Purchasing, Engineering, field crews, QAG (Quality Assurance Group), and the manager of DME. Testing may be required and may take substantial time to review. Vendors are encouraged to submit forms and samples for consideration on the next solicitation for similar items. IFB 6553– Exhibit 3 Page 5 of 5