Loading...
6612 - Electric Meter and Equipment, Addendum 1 - REVISED PRICING SHEETIFB 6612 - Pricing Sheet for SUPPLY OF ELECTRIC METERS AND EQUIPMENT-REVISED Exhibit 1 The respondent shall complete the following section, which directly corresponds to the specifications. The contractor shall not make changes to this format. Product Proposal Pricing (FOB DESTINATION): Item # SECTION A- ELECTRIC METERS with Trilliant Secure Mesh NIC card 1 2 2 3 4 5 6 7 8 9 10 11 12 13 14 15 SECTION B- Photovolatic Meters 16 17 18 19 SECTION C- ELECTRIC SOCKETS 20 21 SECTION D- SECONDARY INSTRUMENT RATED TRANSFORMERS 22 23 24 25 26 SECTION E- PRIMARY INSTRUMENT RATED TRANSFORMERS 27 28 29 30 31 32 33 34 35 36 37 SECTION F- TRILLIANT SECURE MESH AMI EQUIPMENT 38 39 40 41 42 Total Cost of Products (Annual) *NOTE: PLEASE EMAIL THIS EXHIBIT 1 AS AN EXCEL FILE TO EBIDS@CITYOFDENTON.COM EST. ANNUAL QTY 20 12 10 7000 510 40 20 40 20 30 40 300 48 200 5 5 5 5 50 40 120 300 30 6 36 60 6 6 3 3 3 3 3 3 3 3 3 1 1 1 1 1 UOM EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA Respondent's Company Name: City and State: Product Description Meter, Single Phase, Class 100, 120V, 2 wire, 1s Meter, Single Phase, Class 100, 120V, 2 wire, 1s w/ Disconnect under the cover Meter, Single Phase, Class 100, 120V, 2 wire, 1s, w / kW Demand Meter, Single Phase, Class 200, 240V, 3 wire, 2s with Disconnect under the cover Meter, Single Phase, Class 200, 240V, 3 wire, 2s, w/ kW Demand Meter, Single Phase, Class 200, 120-480V, 3 wire, 2s, w/ kW Demand Meter, Single Phase, Class 320, 240V, 3 wire, 2s Meter, Single Phase, Class 320, 120-480V, 3 wire, 2s, w / kW Demand Meter, Single Phase, Class 20, 120-480V, 3 wire, 4s, w / kW Demand Meter, Single Phase, Class 200, 120V, 3 wire, 12s /25s with Disconnect under the cover Meter, Single Phase, Class 200, 120-480V, 3 wire, 12s/25s, w/ kW Demand Meter, Three Phase, Class 200, 120-480V, 4 wire, 15-16s, w/ kW Demand Meter, Three Phase, Class 320, 120-480V, 4 wire, 15-16s, w/ kW Demand Meter, Three Phase, Class 20, 120-480V, 4 wire, 8-9s, w/ kW Demand Meter, Three Phase, Class 20, 120-480V, 4 wire, 8-9s, kWH, kW/kVA Demand (4 quadrant kVA metering) Option: KYZ Pulse Initiator Board Meter, Three Phase, Class 20, 120-480V, 4 wire, 8-9s, kWH, kW/kVA Demand capable of alpha/numeric labeling of displays Meter, Three Phase, Class 200, 120-480V, 4 wire, 15-16s, kWH, kW Demand capable of alpha/numeric labeling of displays Meter, Single Phase, Class 200, 120-480V, 3 wire, 2s, kWH, kW Demand capable of alpha/numeric labeling of displays Meter, Single Phase, Class 200, 240V, 3 wire, 2s with Disconnect under the cover capable of alpha/numeric labeling of the displays Socket, Ring-less, 6 Terminal, 20 amp, One piece cover, Closure Plate, Seven Pole Test switch(Milbank #TS07-0105 or equivalent), Pre-wired with DME's color-coded wiring diagram for a 4S meter Socket, Ring-less, 13 Terminal, 20 amp, One piece cover, Closure Plate, Ten Pole Test switch(Milbank #TS10-0109 or equivalent), Pre-wired with DME's color-coded wiring diagram for a 8-9S meter Current Transformers: 600 volt, over-bushing type 500:5, ANSI meter accuracy class .3B-0.1, rating factor of 4.0 @ 30 C. Extended range (4%-40% at .6 accuracy as defined by IEEE C57.13) Current Transformers: 600 volt, over-bushing type 1000:5, ANSI meter accuracy class .3B-0.9, rating factor of 2.0 @ 30 C. Extended range (4%-40% at .6 accuracy as defined by IEEE C57.13) Current Transformers: 600 volt, over-bushing type 2000:5, ANSI meter accuracy class .3B-1.8, rating factor of 2.0 @ 30 C. Extended range (4%-40% at .6 accuracy as difined by C57.13) Current Transformers: 100:5 ratio, 600 volt, window type. 2.5" window, ANSI meter accuracy class .3B-0.5, rating factor of 4.0 @ 30 C. Current Transformers: 500:5 ratio, 600 volt, window type. 2.5" window, ANSI meter accuracy class .3B-0.5, rating factor of 4.0 @ 30 C. Extended range (4%-40% at .6 accuracy as difined by IEEE C57.13) Voltage Transformers: ANSI accuracy class 0.3 thru Burden Z, Thermal Rating 1500 VA at 30 degrees C ambient, 8400:120 voltage rating, single bushing, 110 KV BIL, ABB Type VOZ-11M, Part #7525A91G07 or equal Current Transformers: ANSI accuracy class .3 thru B-0.5, 110 KV, BIL, 13,800 nominal or 15 KV acceptable 15:5 ABB Type KON-11, Part #7524A25G02 or equal 20:5 ABB Type KON-11, Part #7524A25G03 or equal 25:5 ABB Type KON-11, Part #7524A25G04 or equal 30:5 ABB Type KON-11, Part #7524A25G05 or equal 40:5 ABB Type KON-11, Part #7524A25G06 or equal 50:5 ABB Type KON-11, Part #7524A25G07 or equal 100:5 ABB Type KON-11, Part #7524A25G09 or equal 200:5 ABB Type KON-11, Part #7524A25G11 or equal 200:5 ratio Primary Current Transformer Accuracy class 0.15% extended range, RF 1.5 @ 30c, 13,800v or 15kV acceptable Trilliant Secure Mesh PSU Card Trilliant Secure Mesh PSU Trilliant Secure Mesh Extender Bridge Trilliant Secure Mesh Repeaters Trilliant Secure Mesh Gateway Unit Price 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Extended Price 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Estimated Delivery ARO (Days)