HomeMy WebLinkAbout1995-028E:\WPDOCS\ORD\TGS.0
ORDINANCE NO. _1_,L--0-21P
AN ORDINANCE OF THE CITY OF DENTON, TEXAS, AMENDING THE SCHEDULE OF
ELECTRIC RATES BY ADOPTING AN AMENDED SCHEDULE TGS (GENERAL SERVICE
TIME OF USE RATE); AND PROVIDING FOR AN EFFECTIVE DATE.
THE COUNCIL OF THE CITY OF DENTON HEREBY ORDAINS:
SECTION I. That the Schedule of Rates for electrical services,
as adopted by Ordinance No. 94-162, is amended by amending the
provisions of Schedule TGS (General Service Time of Use Rate), a
copy of which is attached hereto and incorporated by reference
herein.
SECTION II. That this ordinance supersedes Ordinance No. 94-
162 in all respects.
SECTION III. That this ordinance shall become effective
immediately upon its passage and /approval.
PASSED AND APPROVED this the day of f 1995.
ATTEST:
JENNIFER WALTERS, CITY SECRETARY
m
AP
-NEY
SCHEDULE TGS
GENERAL SERVICE TIME OF USE
(Effective 2/15/95)
APPLICATION
Applicable to any customer having a minimum demand of 250 KW
for all electric service supplied at one point of delivery and
measured through one meter, with the City providing all facilities
necessary to receive primary voltage service. Supplementary ser-
vice will be available subject to the applicable rider. Not appli-
cable to resale or temporary service. Customers electing this rate
must remain on this rate for a minimum of twelve (12) continuous
billing months.
NET MONTHLY RATE
(1) Customer Facility Charge $70.70/30 days
(2) On -Peak Demand Charge
(3) System Demand Charge
(4) Energy Charge
(5) Energy Cost Adjustment
(6) Power Cost Adjustment:
MINIMUM BILLING
$12.20/KW of On -Peak Demand
$ 2.40/KW of System Demand
0.51C/KWH
Per Schedule ECA
Per Schedule PCA
The minimum monthly bill shall be the sum of the Customer
Facility Charge, the On -Peak Demand Charge, and the System Demand
Charge. The October through May demand charge shall be the
measured system demand plus not less than 1006 of the maximum
monthly on -peak demand charge for any month during the months of
June through September in the twelve (12) months immediately
preceding the current month.
TYPE OF SERVICE
Secondary or primary service available to commercial and
industrial customers. Primary voltage service is available to any
customer with a minimum demand of 250 KW. Primary service is
rendered at one point on the customer's premises at a nominal
voltage of 13,200 volts.
The City will supply single-phase service (or three-phase ser-
vice if available at the point of delivery) at sixty (60) cycles
and at any standard voltages available from the City's distribution
system through one standard transformation. Where service of the
type desired by the customer is not already available at the point
of service, special contract arrangements between the City and the
customer may be required.
PRIMARY SERVICE DISCOUNT
Customers who own, operate and maintain all facilities neces-
sary to receive three phase primary voltage service and all trans-
formation facilities required for conversion to utilization voltage
shall receive a discount of 0.34/KWH. If primary service is provi-
ded and the City owns and operates all facilities and transforma-
tion equipment necessary to receive primary voltage service, a
discount of 0.i�/KW will be applied to the customer's bill. The
City shall own, operate and maintain all metering facilities,
either at primary or secondary voltage, at the City's option.
DETERMINATION OF ON -PEAK DEMAND
The on -peak demand shall be determined by the KW demand sup-
plied during the fifteen (15) minute period of maximum use each
month during on -peak hours as recorded by the City's demand meter
and adjusted for power factor, but not less than one hundred per-
cent (100%) of the maximum on -peak demand similarly determined dur-
ing the months of June through September in the twelve (12) months
immediately preceding the current month. If the customer is new or
does not have a history of use for any month during the period June
through September, the on -peak demand charge shall begin when the
customer establishes a history for any month during the June
through September period. The on -peak demand will be billed every
month once an on -peak demand history is established.
DETERMINATION OF SYSTEM DEMAND
The system demand shall be determined by the maximum KW demand
supplied during the fifteen (15) minute period of maximum use each
month during off-peak hours as recorded by the City's demand meter
and adjusted for power factor. The system demand will be billed
every month.
POWER FACTOR PENALTY
The City reserves the right to make tests to determine the
power factor of the customer's installation served either by
measurement during periods of maximum demand or by measurement of
the average power factor for the monthly billing period. If the
power factor is below ninety percent, the demand for billing
purposes will be determined by multiplying the uncorrected KW
billing demand by 90% and dividing by the determined power factor.
DEFINITION OF ON -PEAK HOURS
The City's on -peak hours, for the purpose of this rate sched-
ule, are designated as being from 2:00 P.M. to 7:00 P.M. each
Monday through Friday, for the months of June through September.
The City's on -peak hours may be changed from time to time and the
customer will be notified twelve (12) months before such changes
become effective.
DEFINITION OF SYSTEM (OFF-PEAK) HOURS
The City's system (off-peak) hours, for the purpose of this
rate schedule, shall be all hours not designated as on -peak hours.
SUPPLEMENTAL POWER RIDER
Customers requesting standby or supplementary power shall be
allowed service under this rate schedule; however, the determina-
tion of off-peak demand shall be adjusted to read:
The off-peak demand shall be the sum of the maximum KW
demand supplied during the fifteen (15) minute period of maxi-
mum use during off-peak hours as recorded by the City's demand
meter, plus the KW nameplate ratings) of the customer's gen-
erator(s). In the event the customer's generator(s) is/are
off-line at the time of the establishment of the maximum
system demand, the KW nameplate rating of the generator(s)
unavailable for service shall be removed from determination of
the system demand.
SPECIAL FACILITIES
All services which require special facilities in order to meet
the customer's service requirements shall be provided subject to
special facilities rider.
PRORATION OF UTILITY BILLS
(a) Billing for the Facility Charge shall be based on 12
billings annually and prorated for longer or shorter
periods using the following formula:
Actual days in reading period x customer facility charge
30 days
(b) Billing for demand shall be calculated on a 30-day-per-
month basis and pro rated for longer or shorter billing
periods using the following formula:
Actual days in reading period x KW Demand x Rate
30 days
ENERGY CHARGE
Billing for the energy charge shall be based on actual KWH
consumption during the billing period.
Formula:
KWH in rate block x Rate per KWH in rate block
ENERGY COST ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule ECA.
POWER COST ADJUSTMENT
A charge per KW of demand for fixed purchased power cost
calculated in accordance with Schedule PCA.
PAYMENT
Bills are due when rendered, and become past due if not paid
within 15 calendar days from date of issuance.