HomeMy WebLinkAbout1992-172,lecrete o
NOTE AMENDED BY ORDINANCE 92-214 A COPY OF WHICH IS ATTACHED
ORDINANCE NO.
AN ORDINANCE AMENDING THE SCHEDULE OF ELECTRIC RATES, ADDING NEW
GENERAL SERVICF LP.RGE (GSL), GENERAL SERVICE SMALL (GSS), EXPERI-
MENTAL WEEKEND (E11K), APPLIANCE REBATE (APR), AIR CONDITIONING
CYCLING REBATE (ACR), AND VOLUNTARY LOAD REDUCTION (VLR) RATE
SCHEDULES; DELETING THE GENERAL SERVICE (GS), LARGE PRIMARY (LP),
GENERAL SERVICE PRIMARY (GP), GENERAL SERVICE PRIMARY TIME OF USE
(TGP), AND LARGE PRIMARY TIME OF USE (TLP) RATE SCHEDULES, PROVI-
DING FOR A SEVERABILITY CLAUSE; AND PROVIDING FOR AN EFFECTIVE
DATE
THE COUNCIL OF THE CITY OF DENTON HEREBY ORDAINS:
SECTION I.
That the Schedule of Rates for electrical services as provided
for in Chapter 26 of the Code of Ordinances, is amended to read as
follows
R1
R2
GSL
GSS
EWK
G1
TR
TGS
LS
LO
LT
DO
T1
P1
AF
ES
DL
IDR
TS
UPS
ECA
APR
ACR
V LR
ARTICLE I. ELECTRIC RATE SCHEDULES
Residential Service Rate
Residential Service Rate
General Service Large
General Service Small
Experimental Weekend
Local Government Lighting & Power
(City, County, Independent
Residential Time of Use Rate
General Service Time of Use Rate
Street Lighting
other Lighting
Traffic Lighting
PAGE
4
6
9
12
Service Rate 14
School District)
Dusk -to -Dawn Lighting (Security Light)
Temporary Service Schedule
Interruptible Primary Service
Athletic: Field
Standby, Si-plementary & Maintenance Service
Decorat ve Lighting
Industr.al Development Rate
Thermal Storage Rate
Uninterruptible Power Supply
Energy Cost Adjustment
Appliance Rebate
Air Conditioner Cycling Rebate
Voluntary Load Reduction
16
18
21
23
25
26
28
30
33
35
40
41
42
43
45
46
51
52
SCHEDULE R1
RESIDENTIAL SERVICE
(Effective 10/07/92)
APPLICATION
Applicable to all electric service used for residential pur-
poses in a single family dwelling or an individually metered
apartment, supplied at one point of delivery and measured through
one meter where usage is not in excess of 700 KWH per 30-day month
during the billing months MAY through OCTOBER. If usage in any
such month exceeds 700 KWH, billing will be rendered that month
under Rate Schedule R-2 and thereafter for a period extending
through the 12 billing months of the next year ending with the
October billing Annually, in November, the customer may again
qualify for the R-1 rate provided that consumption has not exceeded
700 KWH per 30-day month during the previous six summer months.
Where individual dwelling units are being served through the
same meter and the KWH in the billing months of MAY through OCTOBER
exceed 700 KWH times the number of dwelling units, the billing for
that month and thereafter will be rendered under Rate Schedule R-2
NET MONTHLY RATE
(1) Customer Facility Charge $6.50/30 days
(2) Energy Charge 4 204/KWH
(3) Energy Cost Adjustment Schedule ECA
MINIMUM BILLING
$6.50/30 days
TYPE OF SERVIC
The City will supply single-phase service at any standard volt-
ages available from the City's distribution system through one
standard transformation
PAYMENT
Bills are due when rendered, and become past due if not paid
within 15 calendar days from date of issuance.
SPECIAL FACILITIES
All services which require special facilities in order to meet
customer's service requirements shall be provided sub3ect to the
special facilities rider
PAGE 2
PRORATION OF UTILITY BILLS
Billing for the Facility charge shall be based on 12 billings
annually
Formula:
Actual days in reading period x customer facility charge
33 days
ENERGY COST ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule ECA.
PAGE 3
SCHEDULE R2
RESIDENTIAL SERVICE
(Effective 10/07/92)
APPLICATION
Applicable to any customer for all electric service used for
residential purposes in an individual private dwelling or an indi-
vidually metered apartment, supplied at one point of delivery and
measured through one meter. Also applicable to any customer heat-
ing with electric energy, resistance or heat pump
Not applicable to resale service in any event, nor to tempo-
rary, standby, or supplementary service except in con3unction with
applicable rider
NET MONTHLY RATE WINTER
Billing months of
NOV through APRIL
(1) Customer Facility Charge
Single Phase
Three Phase
(2) Energy Charge
First 1,000 KWH
Additional KWH
First 3,000 KWH
Additional KWH
$ 7 50/30 days
$15.00/30 days
4 200/KWH
3.80C/KWH
(3) Energy Cost Ad3ustment
MINIMUM BILLING
Single Phase
Three Phase
TYPE OF SERVICE
Schedule ECA
$ 7.50/30 days
$15 00/30 days
SUMMER
Billing months of
MAY through OCT
$ 7.50/30 days
$15 00/30 days
5.45C/KWH
6.004/KWH
Schedule ECA
$ 7.50/30 days
$15 00/30 days
The City will supply single-phase service (or three-phase ser-
vice if available at the point of delivery) at sixty (60) cycles
and at any standard voltages available from the City Is distribution
system through one standard transformation Where service of the
type desired by the customer is not already available at the point
of service, special contract arrangements between the City and the
customer may be required in advance.
PAGE 4
PAYMENT
Bills are due when rendered, and become past due if not paid
within 15 calendar days from date of issuance
SPECIAL FACILITIES
All services which require special facilities in order to meet
customer's service requirements shall be provided subject to the
special facilities rider
PRORATION OF UTILITY BILLS
Billing for the Facility charge shall be based on 12 billings
annually.
Formula.
Actual days ir.readina period x customer facility charge
30 days
ENERGY CHARGE
Billing for the energy charge shall be based on actual KWH con-
sumption during the billing period.
Formula:
KWH in rate block x Rate per KWH in rate block
ENERGY COSH' ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule ECA.
PAGE 5
SCHEDULE GSL
GENERAL SERVICE LARGE
(Effective 10/07/92)
APPLICATION
The GSL Rate is applicable to any customer having a minimum
actual demand of 250 KW for all electric service supplied at one
point of delivery and measured through one meter
Customers with an average actual demand equal to or greater
than 18o KW during the previous twelve month period may be
allowed service under this rate, subject to the minimum billing
provision
Customers who elect to discontinue service under this rate are
ineligible for service under this rate for twelve months.
Not applicable to resale service in any event, nor to tempo-
rary, standby or supplementary service except in conjunction with
applicable rider
NET MONTHLY RATE
(1) Customer Facility Charge
(2) Demand Charge
(3) Energy Charge
(4) Energy Cost Adjustment
MINIMUM BILLING
$60.00 per 30 days
$ 9 00 per KW of demand per
30 days
1 40C/KWH for all KWH
Schedule ECA
An amount equal to the facility charge plus the greater of 1)
demand charge as calculated on 250 KW, or 2) seventy percent (70%)
of the maximum monthly demand charge for any month during the pre-
ceding months of May through October.
TYPE OF SERVICE
Secondary or primary service available to commercial and indus-
trial customers. Primary service is rendered at one point on the
customer's premises at a nominal voltage of 13,200 volts
PRIMARY SERVICE DISCOUNT
Customers who own, operate, and maintain all facilities neces-
sary to receive three phase primary voltage service and all trans-
formation facilities required for conversion to utilization voltage
shall receive a discount of 0.3Cr/KWH. Primary service customers
PAGE 6
utilizing City owned and operated facility and transformation
equipment necessary to receive primary voltage service shall
receive a discount of 0 1G/KWH. The City shall own, operate and
maintain all metering facilities, either at primary or secondary
voltage.
PAYMENT
Bills are due when rendered, and become past due if not paid
within 15 calendar days from date of issuance
DETERMINATION OF DEMAND
The demand shall be determined by the KW supplied during the
15-minute period o- maximum use during the current month as deter-
mined by City's demand meter, but shall not be less than 70% of the
highest monthly demand determined during the billing months of MAY
through OCTOBER in the 12 months immediately preceding the current
month
POWER FACTOR
The City reserves the right to make tests to determine eligi-
bility for the GSL rate, and to determine the power factor of the
customer's installation served either by measurement during periods
of maximum demand or by measurement of the average power factor for
the monthly billing period. If the power factor is below ninety
percent, the demand for billing purposes will be determined by
multiplying the uncorrected KW billing demand by 90% and dividing
by the determined power factor
SPECIAL FACILITIES
All services dnich require special facilities in order to meet
customer's service requirements shall be provided subject to the
special facilities rider
PRORATION OF UTILITY BILLS
(a) Billing for the Facility charge shall be based on 12 bill-
ings annually
Formula
Actual days in reading period x customer facility charge
30 days
PAGE 7
(b) Billing for demand shall be calculated on a 30 day per
month basis and prorated for longer or shorter billing
periods
Formula
Actual dais in reading period x KW demand x Rate
30 days
ENERGY CHARGE
Billing for the energy charge shall be based on actual KWH con-
sumption during the billing period.
Formula:
KWH in rate block x Rate per KWH in rate block
ENERGY COST ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule ECA
PAGE 8
SCHEDULE GSS
GENERAL SERVICE SMALL
(Effective 10/07/92)
APPLICATION
The GSS rate is applicable to any commercial or industrial
customer having a maximum demand less than 250 KW for all electric
service supplied at one point of delivery and measured through one
meter
Not applicable to resale service in any event, nor to tempo-
rary, standby or supplementary service except in con3unction with
applicable rider
NET MONTHLY RATE
(1) Customer Facility Charge
Single Phase
Three Phase
(2) Demand Charge
(3) Energy Charge
First 2500 KWH
All KAH over 2500
$15 00 per 30 days
$20 00 per 30 days
$ 7 00 per KW (first 20 KW
not billed)
6. 564r/KWH
3.500/KWH
(4) Energy Cost Ad3ustment Current ECA Schedule
MINIMUM BILLING
An amount equal to the facility charge plus the greater of: 1)
the demand charge calculated on the actual KW demand, or 2) seventy
percent (70%) of the maximum monthly demand charge for any month
during the preceding months of May through October.
TYPE OF SERVICE
Secondary service available to commercial and industrial
customers
The City will supply single-phase service (or three-phase ser-
vice if available at the point of delivery) at sixty (60) cycles
and at any standard voltages available from the city's distribution
system through one standard transformation. Where service of the
type desired by the customer is not already available at the point
of service, special contract arrangements between the City and the
customer may be required prior to its being furnished.
PAGE 9
PAYMENT
Bills are due when rendered, and become past due if not paid
within 15 calendar days from date of issuance.
DETERMINATION OF DEMAND
The demand shall be determined by the KW supplied during the
15-minute period of maximum use during the current month as deter-
mined by city's demand meter, but shall not be less than 70% of the
highest monthly demand determined during the billing months of MAY
through OCTOBER in the 12 months immediately preceding the current
month In no case, shall billed demand be less than 0 KW
In cases where the connected load is constant, the City may, at
its option, estimate the KW demand. For neon signs, one volt am-
pere shall be considered the equivalent of 3/4 watt.
POWER FACTOR
The City reserves the right to make tests to determine the
power factor of the customer's installation served either by
measurement during periods of maximum demand or by measurement of
the average power factor for the monthly billing period If the
power factor is below ninety percent, the demand for billing
purposes will be determined by multiplying the uncorrected KW
billing demand by 90% and dividing by the determined power factor
SPECIAL FACILITIES
All services which require special facilities in order to meet
customer's service requirements shall be provided subject to the
special facilities rider.
PRORATION OF UTILITY BILLS
(a) Billing for the Facility charge shall be based on 12 bill-
ings annually
Formula:
Actual days in reading period x customer facility charge
30 days
(b) Billing for demand shall be calculated on a 30 day per
month bads and prorated for longer or shorter billing
periods
Formula
Actual days in reading period x adjusted KW demand x Rate
30 days
PAGE 10
ENERGY CHARGE
Billing for the energy charge shall be based on actual KWH con-
sumption during the billing period.
Formula:
KWH in rate block x Rate per KWH in rate block
ENERGY COST ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule ECA.
PAGE 11
SCHEDULE EWK
EXPERIMENTAL WEEKEND RATE
(EFFECTIVE 10/07/92)
APPLICATION
Applicable to any commercial and industrial user whose maximum
demand load occurs during the period from Friday at 12 midnight
through Sunday at 12 midnight and does not experience a demand load
during the period from Sunday 12 midnight through Friday 12 mid-
night that exceeds 80% of the maximum demand load. Customers on
this rate who do not meet the application requirements are ineligi-
ble for service under this rate for twelve (12) months.
Not applicable to resale service in any event, nor to tempo-
rary, standby or supplementary service except in conjunction with
applicable rider
NET MONTHLY RATE
(1) Customer Facility Charge
(2) Demand Charge
(3) Energy Charge
First 2,500 KWH
All over 2,500 KWH
(4) Energy Cost Adjustment
MINIMUM BILLING
$15.00/30 days --Single Phase
$20 00/30 days --Three Phase
$ 5 60/KW (first 20 KW not
billed)
6 56¢/KWH
3.504/KWH
Per Schedule ECA
An amount equal to the demand charge as calculated below plus
$15/month for single phase service or $20/month for three phase
service, per 30 day billing
TYPE OF SERVICE
The City will supply single-phase service (or three-phase ser-
vice if available at the point of delivery) at sixty (60) cycles
and at any standard voltages available from the City's distribution
system through one standard transformation. Where service of the
type desired b} the customer is not already available at the point
of service, special contract arrangements between the City and the
customer may be required.
PAYMENT
Bills are due when rendered and become past due if not paid
within 15 calendar days from date of issuance.
PAGE 12
DETERMINATION OF DEMAND
The demand shall be determined by the KW supplied during the
fifteen (15) minute period of maximum use during the current month
as determined by the City's demand meter Billing shall be based
on an adjusted KW demand, which is the actual demand less 20 KW.
The adjusted KW demand will subsequently be used for billing the
demand portion of the utility bill In no case, shall billed
demand be less than 0 KW
SPECIAL FACILITIES
All services which require special facilities in order to meet
customer's service requirements shall be provided subject to the
special facilities rider
PRORATION OF UTILITY BILLS
Billing for customer facility charge and demand shall be calcu-
lated on a 30-day basis and prorated for longer or shorter billing
period
(a) Billing for the Customer Facility Charge shall be based on
12 billings annually.
Formula:
Actual days in reading period x customer facility charge
30 days
(b) Billing for the Demand Charge shall be based on 12 bill-
ings annually
Formula
Actuai days in reading period x adjusted KW demand x Rate
30 days
ENERGY CHARGE
Billing for the energy charge shall be based on actual KWH con-
sumption during tna billing period
Formula•
KWH in rate block x Rate per KWH in rate block
ENERGY COST ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule ECA
PAGE 13
SCHEDULE G1
LOCAL GOVERNMENT
(Effective 10/07/92)
APPLICATION
Applicable to any local City, County or School District for all
electric service supplied at one point of delivery and measured
through one meter
Not applicable to resale service in any event, nor to tempo-
rary, standby or supplementary service except in conjunction with
applicable rider.
NET MONTHLY RATE
(1) Customer Charge
Single Phase
Three Phase
(2) Demand Charge
(3) Energy Charge
(4) Energy Cost Adjustment
MINIMUM BILLING
$15 00 per 30 days
$20.00 per 30 days
$ 6 0o per KW of demand
2 88C per KWH for all KWH
Current ECA Schedule
An amount equal to the demand charge as calculated below but
not less than fifty percent (50%) of the maximum monthly demand
charge for any month during the preceding months of May through
October plus $15.00/month for single phase service or less than
$20 o0/month for three phase service, per 30 day billing period.
TYPE OF SERVICE
The City will supply single-phase service (or three-phase ser-
vice if available at the point of delivery) at sixty (60) cycles
and at any standard voltages available from the City's distribution
system through one standard transformation Where service of the
type desired by the customer is not already available at the point
of service, special contract arrangements between the City and the
customer may be required
PAYMENT
Bills are due when rendered, and become past due if not paid
within 15 calendar days from date of issuance.
PAGE 14
DETERMINATION OF DEMAND
The demand shall be determined by the KW supplied during the
15-minute period of maximum use during the current month as deter-
mined by City's demand meter
POWER FACTOR
The City resex ves the right to make tests to determine the
power factor of the customer's installation served either by
measurement during periods of maximum demand or by measurement of
the average power factor for the monthly billing period. If the
power factor is below ninety percent, the demand for billing
purposes will be determined by multiplying the uncorrected KW
billing demand by 90% and dividing by the determined power factor
SPECIAL FACILITIES
All services which require special facilities in order to meet
customer's service requirements shall be provided subject to the
special facilities rider
PRORATION OF UTILITY BILLS
(a) Billing for the Facility charge shall be based on 12 bill-
ings annually.
Formula
Actual days in reading Period x customer facility charge
30 days
(b) Billing for demand shall be calculated on a 30 day per
month ba.,is and prorated for longer or shorter billing
periods
Formula
Actual days in reading Period x KW demand x Rate
30 days
ENERGY COST ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule ECA.
PAGE 15
SCHEDULE TR
RESIDENTIAL TIME OF USE
(Effective 10/07/92)
APPLICATION
Applicable to any customer for all electric service used for
residential purposes in an individual private dwelling or an indi-
vidually metered apartment, supplied at one point of delivery and
measured through one meter. Customers applying for the TR rate
must remain on this rate for twelve (12) continuous billing per-
iods
Not applicable to resale service in any event, nor to tempo-
rary, standby, or supplementary service except in conjunction with
applicable rider.
NET MONTHLY RAPE
(1) Customer Facility Charge
Single Phase
Three Phase
(2) Energy Charge
On -Peak Hours
Off -Peak Hours
(3) Energy Cost Adjustment
$15 00/30 days
$20.00/30 days
24.80 /KWH
1.40 /KWH
Schedule ECA
MINIMUM BILLING
The minimum monthly bill shall be the Customer Facility Charge
TYPE OF SERVICE
Single-phase or three-phase at sixty (60) cycles at secondary
distribution voltage Where service of the type desired by the
customer is not already available at the point of service, special
contract arrangements between the City and the customer may be
required prior to its being furnished
DEFINITION OF ON -PEAK HOURS
The City's on -peak hours, for the purpose of this rate sched-
ule, are designated as being from 1.00 P.M. to 8:00 P.M. each
Monday through Friday, staring on June 1 and continuing through
September 30 each year. The City's on -peak hours may be changed
from time to time and the customer will be notified twelve (12)
months before such changes become effective.
PAGE 16
DEFINITION OF OFF-PEAK HOURS
The City's off-peak hours, for the purpose of this rate sched-
ule, shall be all hours not designated as on -peak hours
SPECIAL FACILITIES
All services which require special facilities in order to meet
customer's service requirements shall be provided subject to the
special facilities rider.
PRORATION OF UTILITY BILLS
Billing for the Facility Charge shall be based on 12 billings
annually using the following formula.
Actual days in reading period x customer facility charge
30 days
ENERGY CHARGE
Billing for the energy charge shall be based on actual KWH con-
sumption during the billing period.
Formula:
KWH in rate block x Rate per KWH in rate block
ENERGY COST ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule ECA.
PAYMENT
Bills are due when rendered, and become past due if not paid
within 15 calendar days from date of issuance
PAGE 17
SCHEDULE TGS
GENERAL SERVICE TIME OF USE
(Effective 10/07/92)
APPLICATION
Applicable to any customer having a minimum demand of 750 KW
for all electric service supplied at one point of delivery and
measured through one meter, with the City providing all facilities
necessary to receive primary voltage service. Supplementary ser-
vice will be available sub3ect to the applicable rider. Not appli-
cable to resale or temporary service Customers electing this rate
must remain on this rate for a minimum of twelve (12) continuous
billing months.
NET MONTHLY RATE
(1) Customer Facility Charge
(2) On -Peak Demand Charge
(3) System Demand Charge
(4) Energy Charge
(5) Energy Cost Ad3ustment:
MINIMUM BILLING
$70 00/30 days
$10.00/KW of On -Peak Demand
$ 4.00/KW of System Demand
0 50/KWH
Per Schedule ECA
The minimum monthly bill shall be the sum of the Customer
Facility Charge, the On -Peak Demand Charge, and the System Demand
Charge; but not less than 100% of the maximum monthly total demand
charge for any month during the preceding months of May through
October.
TYPE OF SERVICE
Secondary or primary service available to commercial and indus-
trial customers Primary voltage service is available to any cus-
tomer with a minimum demand of 250 KW Primary service is rendered
at one point on the customer's premises at a nominal voltage of
13,200 volts.
The City will supply single-phase service (or three-phase ser-
vice if available at the point of delivery) at sixty (60) cycles
and at any standard voltages available from the City's distribution
system through one standard transformation Where service of the
type desired by the customer is not already available at the point
of service, special contract arrangements between the City and the
customer may be required.
PAGE 18
DETERMINATION OF ON -PEAK DEMAND
The on -peak demand shall be determined by the KW demand sup-
plied during the fifteen (15) minute period of maximum use each
month during on -peak hours as recorded by the City's demand meter
and adjusted for power factor, but not less than one hundred per-
cent (100%) of the maximum on -peak demand similarly determined dur-
ing the billing months of June through September in the twelve (12)
months immediately preceding the current month The on -peak demand
will be billed every month.
DETERMINATION OF SYSTEM DEMAND
The system demand shall be determined by the maximum KW demand
supplied during the fifteen (15) minute period of maximum use each
month as recorded by the City's demand meter and adjusted for power
factor, but not less than one hundred percent (100%) of the maximum
system demand similarly determined during the billing months of
June through September in the twelve (12) months immediately
preceding the current month
POWER FACTOR PENALTY
The City reserves the right to make tests to determine the
power factor of the customer's installation served either by
measurement during periods of maximum demand or by measurement of
the average poser factor for the monthly billing period. If the
power factor is below ninety percent, the demand for billing
purposes will be determined by multiplying the uncorrected KW
billing demand by 90% and dividing by the determined power factor.
DEFINITION OF_JN-PEAK HOURS
The City's on -peak hours, for the purpose of this rate sched-
ule, are designated as being from 1.00 P M to 8.00 P.M. each
Monday through Friday The City's on -peak hours may be changed
from time to time and the customer will be notified twelve (12)
months before to such changes become effective
DEFINITION OF OFF-PEAK HOURS
The City's off-peak hours, for the purpose of this rate sched-
ule, shall be all hours not designated as on -peak hours
SUPPLEMENTAL POWER RIDER
Customers requesting standby or supplementary power shall be
allowed service under this rate schedule; however, the determina-
tion of system demand shall be adjusted to read -
The system demand shall be the sum of the maximum KW
demand supplied during the fifteen (15) minute period of maxi-
mum use as recorded by the City's demand meter plus the KW
nameplate ratLng(s) of the customer's generator(s). In the
PAGE 19
event the customer's generator(s) is/are off-line at the time
of the establishment of the maximum system demand, the KW
nameplate rating of the generator(s) unavailable for service
shall be removed from the determination of the system demand
In no event shall the system demand be less than one hundred
percent (100%) of the maximum system demand similarly deter-
mined during the billing months of June through September in
the twelve (12) months immediately preceding the current month
SPECIAL FACILITIES
All services which require special facilities in order to meet
the customer's service requirements shall be provided subject to
special facilities rider
PRORATION OF UTILITY BILLS
(a) Billing for the Facility Charge shall be based on 12 bill-
ings annually using the following formula.
Actual days in readina period x customer facility charge
30 days
(b) Billing for demand shall be calculated on a 30-day-per-
month basis and pro rated for longer or shorter billing
periods using the following formula
Actual days in reading period x KW Demand x Rate
30 days
ENERGY COST ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule ECA
PAYMENT
Bills are due when rendered, and become past due if not paid
within 15 calendar days from date of issuance.
PRIMARY SERVICE DISCOUNT
Customers oho own, operate and maintain all facilities neces-
sary to receive three phase primary voltage service and all trans-
formation facilities required for conversion to utilization voltage
shall receive a discount of 0 3C/KWH If primary service is
provided and the City owns and operates all facilities and
transformation equipment necessary to receive primary voltage
service, a discount of 0 10/KW will be applied to the customer's
bill The City shall own, operate and maintain all metering
facilities, either at primary or secondary voltage, at the City's
option
PAGE 20
SCHEDULE LS
STREET LIGHTING
APPLICATION
Applicable to all street lighting owned and maintained by the
City of Denton.
NET MONTHLY RATE
(1) Facility Charae See table
Monthly Bulb
(2) Energy Cost AdIustment Current ECA x Wattage Factor
Facility Charge Bulb Wattage Factor
LS
LSA
100W
Sodium Vapor
$
4
75
48
KWH
LSB
250W
Sodium Vapor
$
6
75
105
KWH
LSC
400W
Sodium Vapor
$
8
50
159
KWH
LM
LMA
175W
Mercury Vapor
$
5
50
70
KWH
LMB
250W
Mercury Vapor
$
6
50
98
KWH
LMC
400W
Mercury Vapor
$
8
25
153
KWH
LMD
1000W
Mercury Vapor
$15.00
380
KWH
TYPE OF SERVICE
The City will supply single-phase service (or three-phase ser-
vice if available at the point of delivery) at sixty (60) cycles
and at any standard voltages available from the City's distribution
system through one standard transformation. Where service of the
type desired by the customer is not already available at the point
of service, special contract arrangements between the City and the
customer may be required prior to its being furnished
PAYMENT
Bills are due when rendered, and become past due if not paid
within 15 calendar days from date of issuance.
PRORATION OF UTILITY BILLS
a) Billing for the Facility Charge shall be based on 12 bill-
ings annually based on the following formula
Actual days in reading period x customer facility charge
30 days
PAGE 21
ENERGY COST ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule ECA.
PAGE 22
SCHEDULE LO
OTHER LIGHTING
LOA
APPLICATION
Applicable to State and Local Government agencies that install
and maintain their own street lights, other than the City of
Denton.
BULB WATTAGE
NET MONTHLY RATE FACTOR
LS1
250W
Sodium Vapor
5.140/KWH
105
KWH
LS2
400W
Sodium Vapor
5.144/KWH
159
KWH
LM1
40OW
Mercury Vapor
5.140/KWH
153
KWH
LM2
100ow
Mercury Vapor
5.14G/KWH
380
KWH
LOB
APPLICATION
Applicable to other unmetered lighting services
NET MONTHLY RATE
Total Watts x Hours used per Month x 5 140/KWH
1,000
TYPE OF SERVICE
At the city's available secondary voltage and phase
PAYMENT
Bills are due when rendered, and become past due if not paid
within 15 calendar days from date of issuance.
MAINTENANCE CHARGE
Maintenance expenses billed at cost.
SPECIAL FACILITIES
All services which require special facilities in order to meet
customer's service requirements shall be provided sub3ect to the
special facilities rider.
PAGE 23
ENERGY COST ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule ECA.
PAGE 24
SCHEDULE LT
TRAFFIC LIGHTING
APPLICATION
Applicable to State and Local Government agencies that operate
and maintain their own traffic signals
NET MONTHLY RATE
All KWH 5.14(` per KWH
TYPE OF SERVICE
At the city's available secondary voltage and phase
PAYMENT
Bills are due when rendered, and become past due if not paid
within 15 calendar days from date of issuance.
MAINTENANCE CH4RGE
Maintenance expenses billed at cost
SPECIAL FACILITIES
All services wnich require special facilities in order to meet
customer's service requirements shall be provided subject to the
special facilities rider.
ENERGY COST ADJUSTMENT
A charge p.r KWH of energy taken for fuel cost calculated in
accordance with Schedule ECA.
PAGE 25
SCHEDULE DD
DUSK TO DAWN LIGHTING
APPLICATION
Applicable to any customer within the area served by the City's
electric distribution system for outdoor area lighting when such
lighting facilities are operated as an extension of the City's
distribution system
NET MONTHLY RATE
(1) Facility Charge See table
Monthly Bulb
(2) Energy Cost Adjustment Current ECA x Wattage Factor
Facility Charge Bulb Wattage Factor
DSA
100W
Sodium Vapor
$
7
50
48
KWH
DSB
250W
Sodium Vapor
$
9
75
105
KWH
DSC
400W
Sodium Vapor
$12
00
159
KWH
DMA
175W
Mercury Vapor
$
6
25
70
KWH
DMB
250W
Mercury Vapor
$
7
25
98
KWH
DMC
400W
Mercury Vapor
$
8
00
153
KWH
TYPE OF SERVICE
The City shall furnish, install, maintain and deliver electric
service to automatically controlled, mercury or sodium vapor light-
ing fixtures conforming to the City's standards and subject to its
published rules and regulations.
Where necessary for proper illumination or where existing poles
are inadequate, the City will install or cause to be installed, one
(1) pole for each installed light, at a distance not to exceed
eighty (801) feet from said existing lines, at no charge to the
customer. Each additional pole span shall not exceed a span spac-
ing of one hundred (1001) feet Additional poles required to in-
stall a light in a customer's specifically desired location, and
not having a light installed on same, shall bear the cost.
PAYMENT
Bills are due when rendered, and become past due if not paid
within 15 calendar days from date of issuance.
TERM OF CONTRACT
A two (2) year contract shall be agreed to and signed by each
customer desiring Dusk -to -Dawn Lighting Service authorizing fixed
monthly charges, which may be reviewed annually, and to be applied
PAGE 26
to the monthly municipal utilities bill In the event that a cus-
tomer desired the removal of the unit or continuance o remainder e ser-
vice prior to completion of two (2) years
the
contract period shall become due and payable. After the end of the
initial two (2) year contract, service shall continue on a month -
to -month basis and may be canceled by either party upon thirty (30)
days notice.
SPECIAL FACILITIES
All service which requires special facilities in order to meet
the customer's service requirements shall be provided sub]ect to
special facilities rider.
PRORATION OF UTILITY BILLS
Billing for the Facility charge shall be based on 12 billings
annually.
Formula:
Actual days in reading period x customer facility charge
30 days
ENERGY COST ADJUSTMENT
A charge per RWH of energy taken for fuel cost calculated in
accordance with Sciedule ECA
PAGE 27
SCHEDULE T1
TEMPORARY SERVICE
(Effective 10/07/92)
APPLICATION
Applicable when a customer requests electric service on a short
term or temporary basis where a customer has received a permit from
the City of Denton's Building Inspections Department This rate is
not applicable after the certificate of occupancy has been issued
NET MONTHLY RATE
(1) Facility Charge
Single Phase
Three Phase
(2) Energy Charge
(3) Energy Cost Adjustment
MINIMUM BILLING
TYPE OF SERVICE
$15 00/30 days
$20 00/30 days
6.56(�/KWH
Current ECA Schedule
Facility charge
At the City's available secondary supply
PAYMENT
Bills are due when rendered, and become past due if not paid
within 15 calendar days from date of issuance
ADDITIONAL TEMPORARY SERVICE CHARGES
Labor (Regular Time) $60.00 minimum up to 1 hour $60.00
for each additional hour (to be mea-
sured to the nearest one -quarter hour)
Labor (Overtime) $75 00 minimum up to 1 hour. $75.00
for each additional hour (to be mea-
sured to the nearest one -quarter hour).
Premium time to be added where applica-
ble.
Transportation To be billed by hours or miles, as
applicable, according to the estimated
cost of operating the equipment.
PAGE 28
Material Material that cannot be salvaged to be
billed at Stores cost plus 25% and
applicable sales tax
At the time a temporary service is re-
moved or converted, any loss in the
material installed due to negligence or
willful action by the customer will be
billed separately to customer at Stores
cost plus 25% and sales tax.
SPECIAL FACILITIES
All services which require special facilities in order to meet
the customer's service requirements shall be provided subject to
special facilities rider. See Section 25-23(e) for standard re-
quirements.
PRORATION OF UTILITY BILLS
Billing for the Facility charge shall be based on 12 billings
annually
Formula
Actual davF in reading period x customer facility charge
30 days
ENERGY CHARGE
Billing for the energy charge shall be based on actual KWH con-
sumption during the billing period.
Formula
KWH in rate black x Rate per KWH in rate block
ENERGY COST ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule ECA
PAGE 29
SCHEDULE P1
INTERRUPTIBLE PRIMARY SERVICE
(Effective 10/07/92)
APPLICATION
Applicable to all customers taking primary service at a firm
power load exceeding 1,000 KVA during the months of June, July,
August and September and is, by contract, provided service subject
to load interruptions The City retains the right to limit the
number of customers on this rate if the City's load reduction goals
are met.
NET MONTHLY CHARGE
(1) Facility Charge
(2) Energy Charge
(3) Demand Charge
(Estimated transmission firm)
$70.00/30 days
0 20¢/KWH
$ 4.00/KW
(4) Energy Cost Adjustment Current ECA Schedule
PAYMENT
Bills are due when rendered, and become past due if not paid
within 15 calendar days from date of issuance
MINIMUM BILLING
An amount equal to the demand charge as calculated below but
not less than one hundred percent (100%) of the maximum monthly KW
similarly determined during the previous billing months of MAY
through OCTOBEP in the 12 months ending with the current month, nor
LESS than 1,000 KW
TYPE OF SERVICE
Interruptible primary voltage service (transformation equipment
owned by customer) is available to any customer with a 12-month
minimum monthly demand of 5,000 KW or greater Interruptible pri-
mary service rendered at one point on the customer's premises at a
nominal voltage of 13,200 volts or 69,000 volts three-phase at the
option of the utility
The primary voltage service customer shall own, operate, and
maintain all facilities necessary to receive three phase primary
voltage service and all transformation facilities required for
conversion to utilization voltage. The City shall own, operate and
maintain all metering facilities, either at primary or secondary
voltage, at the Utility's option. Where the City elects to meter
at secondary voltage, two percent shall be added to the demand
PAGE 30
charge, the energy charge and the energy cost ad3ustment charge to
account for transformer losses.
DETERMINATION OF DEMAND
The demand shall be determined by the KW supplied during the
15-minute period of maximum use during the current month as
determined by city's demand meter, but not less than 100% of the
maximum monthly KW similarly determined during the billing months
of MAY through OCTOBER in the 12 months immediately preceding the
current month, nor less than 1,000 KW.
POWER FACTOR REQUIREMENTS AND ADJUSTMENTS
The City reserves the right to make tests to determine the
power factor of the user's installation served hereunder during
periods of maximum demand for the monthly billing periods. Should
the power factor so determined be below ninety (90%) percent, the
demand for billing purposes will be determined by multiplying the
uncorrected KW billing demand by ninety (90%) percent and dividing
by the determined power factor.
SPECIAL FACILITIES
All service which requires special facilities in order to meet
the customer's service requirements shall be provided sub3ect to
special facilities rider
PRORATION OF UTILITY BILLS
(a) Billing tor the Facility charge shall be based on 12 bill-
ings annually
Formula:
Actual days in reading period x customer facility charge
30 days
(b) Billing for demand shall be calculated on a 30 day per
month basis and prorated for longer or shorter billing
periods.
Formula•
Actual days in reading period x KW Demand x Rate
30 days
ENERGY CHARGE
Billing for the energy charge shall be based on actual KWH
consumption during the billing period
PAGE 31
Formula.
KWH in rate block x Rate per KWH in rate block
ENERGY COST AIIfUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule ECA.
PAGE 32
SCHEDULE AF
ATHLETE FIELD
APPLICATION
Applicable to all electric service metered at one point for use
to light specified areas for athletic events where such electrical
use will not occur between the hours of 10:00 A.M and 7:00 P.M.
for the months of June through September.
NET MONTHLY RATE
(1) Customer Facilities Charge
Single Phase
Three Phase
(2) Energy Charge
(3)
(4)
$20 00 per 30 days
$30.00 per 30 days
Billing months of June through September.
All Other Hours (Off Peak) 3 75(` per KWH
1:00 PM to 7.00 PM (Peak) 7 50G per KWH
(Weekdays excluding City Holidays)
Billing months of October through May
All hours
Demand Charge
3 750/KWH
Billing :n2nths of June through September
All Other Hours (Off Peak) $1.00 per KW per
30 days
1:00 PM to 7 00 PM (Peak) $4 50 per KW per
30 days
Billing months of October through May:
All hours
Energy Cost Adjustment
MINIMUM BILLING
PAGE 33
$1 00 per KW per
30 days
Current ECA Schedule
Facility Charge
TYPE OF SERVICE
At the city's available secondary voltage and available phase.
For use only between the hours of 7:00 P M. and 10:00 A.M. from
June through September and all hours from October through May.
POWER FACTOR
The City reserves the right to make tests to determine the
power factor of the customer's installation served during periods
of maximum demand or by measurement of the average power factor for
the monthly billing period. If the power factor is below ninety
percent, the demand for billing purposes will be determined by
multiplying the uncorrected KW billing demand by 90% and dividing
by the determined power factor.
SPECIAL FACILITIES
All services which require special facilities in order to meet
customer's service requirements shall be provided subject to the
special facilities rider.
PRORATION OF UTILITY BILLS
(a) Billing for the Facility charge shall be based on 12 bill-
ings annually
Formula.
Actual days in reading period x customer facility charge
30 days
(b) Billing for demand shall be calculated on a 30 day per
month basis and prorated for longer or shorter billing
periods.
Formula:
Actual days in reading period x KW demand x Rate
30 days
ENERGY CHARGE
Billing for the energy charge shall be based on actual KWH con-
sumption during the billing period
Formula:
KWH in rate block x Rate per KWH in rate block
ENERGY COST ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule ECA.
PAGE 34
SCHEDULE ES
STANDBY, SUPPLEMENTARY AND MAINTENANCE SERVICE
(Effective 10/07/92)
APPLICATION
Applicable in all areas served by the City to customers who:
(1) own and/or operate an electric power generation facility
mainly used for non -emergency uses and which has a total
nameplate or effective capacity (whichever is lesser) of
fifty (50) KW or more in parallel with the City's electric
system for the purpose of generating power for the custom-
er's own consumption, and
(2) employ equipment which is compatible with the City's elec-
tric system at the customer's delivery point and which
will cause no damage to the City's electric system or
equipment or present undue hazards to City personnel, and
(3) own and/or operate an electrical generating facility which
has been certified annually by a registered professional
engineer practicing in the utility or Independent Power
Production Industry to be a functioning and reliable
generating facility
(4) operate an electrical power generating system at least
6,500 hours annually.
(5) execute an agreement for interconnection and parallel
operation with the City.
INTERCONNECTION COSTS
The customer.hall reimburse the City for any equipment or
facilities required as a result of the installation by the customer
of generation in parallel with the City's electric system.
The customer shall pay all costs of the City to extend its
facilities or modify them at the time of interconnection, or at
some future time in order to permit parallel operation of the
customer's facility
TYPE OF SERVICE
The City shall supply alternating current at sixty (60) cycles
and at the voltage and phase of the City's electric system most
available to the location of the customer. The primary voltage
customer shall own, operate and maintain all facilities necessary
to receive three phase primary voltage service and all transforma-
tion facilities required for conversion to utilization voltage.
The City shall own, operate and maintain all metering facilities,
PAGE 35
either at primary or secondary voltage, at the city's option.
Where the City elects to meter at secondary voltage, the secondary
energy and on- peak demand charges shall apply
NET MONTHLY_RATE
ing.
(1) Facility Charge
(2) Demand Charges:
On -Peak Demand
System Demand
(3) Energy Charges•
Non -Emergency Energy
Emergercy Energy
(5) Energy Cost Adjustment
Primary
Service
$60.00/30 days
$11.00/KW
$ 4 00/KW
0 20/KWH
5.2G/KWH
Per Sch ECA
Secondary
Service
$25.00/30 days
$11.00/KW
$ 4.00/KW
0 5C/KWH
5. 3 V`/KWH
Per Sch ECA
MINIMUM BILLING
The minimum monthly billing shall be the higher of the follow-
(1) The sum of the Customer Facility Charge, the On -Peak
Demand Charge, and the System Demand Charge, or
(2) A charge of $1 00 per KVA of installed transformer capaci-
ty
DETERMINATION OF ON -PEAK DEMAND
The on -peak demand shall be determined by the KW demand
supplied by the City during the fifteen (15) minute period of
maximum use during the on -peak hours as recorded by the City's
demand meter and adjusted for power factor, but not less than one
hundred percent (100%) of the maximum on -peak demand which occurred
during the billing months of June through September in the twelve
(12) months immediately preceding the current month
DETERMINATION OF ON -PEAK DEMAND - COGENERATION UNITS NOT
OPERATING AND CUSTOMER'S PEAK DID NOT CONTRIBUTE TO CITY'S ANNUAL
SYSTEM PEAK
If a customer's cogeneration unit(s) is/are off during peak
hours, and the customer's peak did not contribute to the City's
annual system peak, and the cogeneration unit is one (1) MW or
larger, then the nameplate rating of the customer's unit(s) shall
be deducted from the peak demand.
PAGE 36
The customer shall be charged the appropriate on -peak demand
charges for the KW supplied by the City for the succeeding twelve
(12) months.
DETERMINATION OF SYSTEM DEMAND
The system demand shall be determined by the sum of the KW
demand supplied during the fifteen (15) minute period of maximum
use as recorded by the City's demand meter, plus the KW nameplate
rating(s) of the customers generator(s).
In no event shall the system demand be less than seventy per-
cent (70%) of the maximum on -peak demand similarly determined dur-
ing the billing months of June through September in the twelve (12)
months immediately preceding the current month
DETERMINATION OF NON -EMERGENCY ENERGY
All energy supplied to customers whose generating units are
less than one (1) MW capacity
DETERMINATION OF EMERGENCY ENERGY
Emergency energy is all energy supplied by the City during peak
hours of operation to displace energy normally supplied by custom-
er's one (1) MW or larger unit.
POWER FACTOR PENALTY
The City reserves the right to determine the power factor of
the customer's installation served during periods of maximum demand
or by measurement of the average power factor for the monthly bill-
ing period. If the power factor is below ninety percent (90%) dur-
ing on -peak hours, the demand for billing purposes will be deter-
mined by multiplying the uncorrected KW billing demand by 90% and
dividing by the determined power factor The formula is as fol-
lows
Unadjusted billing demand x .9
Determined power factor
DEFINITION OF ON -PEAK HOURS
The City's on -peak hours, for the purpose of this rate sched-
ule, are designated as being from 1.00 P M. to 8:00 P.M. each
Monday through Friday
DEFINITION OF OFF-PEAK HOURS
The City's off-peak hours, for the purpose of this rate sched-
ule, shall be all hours not designated as on -peak hours.
PAGE 37
SPECIAL FACILITIES
All services which require special facilitle: in order to meet
customer's service requirements shall be provided subject to the
special facilities rider.
PRORATION OF UTILITY BILLS
(a) Billing for demand shall be calculated on a 30 day per
month basis and prorated for longer or shorter billing
periods using the following formula•
Actual days in reading period x customer facility charge
30 days
(b) Billing for demand shall be calculated on a 30 day per
month basis and prorated for longer or shorter billing
periods using the following formula•
Actual days in reading period x KW Billing Demand x Rate
30 days
ENERGY CHARGE
Billing for energy shall be based on actual KWH consumption
during the billing period.
Formula•
KWH in rate block x Rate per KWH in rate block
CREDIT FOR ENERGY DELIVERED INTO CITY'S SYSTEM DURING ON -PEAK
HOURS
If Customer -produced energy is fed back into the City's system
during on -peak hours, an amount equal to fuel cost calculated in
accordance with Schedule ECA, as applicable to such energy is cred-
ited monthly, provided that Customer has paid the City for neces-
sary added metering, protective and other equipment as determined
by the City
CREDIT FOR ENERGY DELIVERED INTO CITY'S SYSTEM DURING OFF-PEAK
HOURS
If Customer -produced energy is fed back into the City's system
during off-peak hours, an amount equal to $0.01241 per KWH (for
each KWH delivered back into the City's system) will be credited
monthly, provided that Customer has paid the City for necessary
added metering, protective and other equipment as determined by the
City
PAGE 38
ENERGY COST ADJUSTMENT
A charge per M4H of energy taken for fuel cost calculated in
accordance with Schedule ECA
PAYMENT
Bills are due when rendered, and become past due if not paid
within twenty (20) calendar days from date of issuance
LATE PAYMENT CHARGES
Bills are considered past due if not received within twenty
(20) calendar days and shall be accessed a late payment charge of
one and one-half percent (1 5%) per month on any unpaid balance
PAGE 39
SCHEDULE DL
DECORATIVE LIGHTING
APPLICATION
Applicable to any customer on the perimeter of the square ser-
ved by the City's electric distribution system for outdoor area
lighting when such lighting facilities are operated as an extension
of the City's distribution system.
NET MONTHLY RATE
(1) Facility Charge $3 70
(2) Energy Cost Adjustment agrMonthly B
Factor, based on b Watt-
eKWH per
Customer
TYPE OF SERVICE
The City shall furnish, install, maintain and deliver electric
service to automatically controlled lighting fixtures conforming to
the City's standards and subject to its published rules and regula-
tions The service is provided between dusk and midnight.
PAYMENT
Bills are due when rendered, and become past due if not paid
within 15 calendar days from date of issuance
SPECIAL FACILITIES
All service which requires special facilities in order to meet
the customer's service requirements shall be provided subject to
special facilities rider.
PRORATION OF UTILITY BILLS
Billing for the Facility Charge shall be based on 12 billings
annually.
Formula*
Actual days in reading period x Facility Charge
30 days
ENERGY COST ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule ECA
PAGE 40
SCHEDULE IDR
INDUSTRIAL/ECONOMIC DEVELOPMENT RIDER
AVAILABILITY
This rider is available to the customers who receive service
from either of City's Rate Schedules GSS or GSL
APPLICATION
This rider is available to electric service supplied at any one
location and measured through one meter. This is for firm electric
service applicable to new customers and existing customers as de-
scribed below.
(1) New customers whose electric service represents demand not
previously served by the City at any location in the
City's service area in the last 12 months and where such
metered demand is in excess of 200 KW
(2) Existing customers served under Rate Schedules GSS or GSL
who add additional metered demand of at least 200 KW on
top of their existing level of demand. This additional
load will be separately metered
Under no circumstances may this rider be used to reduce the
current amount of other firm service billed to the customer. Dur-
ing the term of this agreement, the customer may not reduce other
firm service peak demand
NET MONTHLY RACE
The customer shall be charged under the appropriate applicable
rate schedules with the exception that the monthly billing demand
or system demand will be adjusted in accordance with the following
table:
Reduction to Billing
Time Period Demand or System Demand
First Year
50%
Second Year
40%
Third Year
30%
Fourth Year
20%
Fifth Year
10%
CONTRACT PERIOD
The term of the contract will be a five-year period.
PAGE 41
SCHEDULE TS
THERMAL STORAGE INCENTIVE
(Effective 10/07/92)
APPLICATION
Applicable to any customer who agrees to be on Time -of -Use rate
for five (5) years and who has a thermal storage facility of a min-
imum storage capacity of 500,000 BTU.
THERMAL STORAGE INCENTIVE PAYMENTS
First 500 KW shifted $250/KW
to off-peak hours
Additional KW shifted $125/KW
to off-peak hours
Thermal storage incentive payments shall be made to qualifying
customers based on the following method•
A design shall be submitted to the Director of Electric Utili-
ties for approval The thermal storage equipment shall be checked
for input electric demand (KW) and output capacity (BTU). The
system shall be limited for incentive payment to a maximum of
12,000 BTU per 500 square feet for the conditioned area of the
facility to be served
Upon completion, the input-output of the thermal storage units
will be measured by the City of Denton. The customer may observe
and verify all information and calculations for the actual size of
the facility. Auxiliary equipment used to circulate fluid or air
handlers which would operate under normal peak periods will not be
included in calculating the KW load for incentive payments.
PAGE 42
SCHEDULE UPS
UNINTERRUPTIBLE POWER SUPPLY
APPLICATION
Applicable to any customer who, by written agreement, receives
service for unlnterruptible power supply for a computer or other
electrical equipment.
Not applicable for resale service in any event, nor to tempo-
rary or standby service except in conjunction with applicable
rider.
NET MONTHLY RATE
(1) Customer Facility Charge:
250 W Power Standby Unit $ 7 55/30 days
1,200 W Power Standby Unit $30.95/30 days
(2) Installation Charge $25.00
For any W Power Standby Unit other than above, the monthly
customer charge will be based on the following formula
(1) Monthly Charge
5 of Annual Maintenance Cost PLUS
12 months
6$ AnnuaL Return of Investment PLUS
12 months
8% Interest on a 5 Year Life
TYPE OF SERVICE
The City shall furnish, install, maintain an automatically
controlled alternating current power backup unit conforming to the
City's standards and subject to its published rules and regula-
tions.
PAYMENT
Bills are due when rendered, and become past due if not paid
within 15 calendar days from date of issuance.
SPECIAL FACILITIES
All services w'iich require special facilities in order to meet
customer's service requirements shall be provided subject to the
special facilities rider.
PAGE 43
PRORATION OF UTILITY BILLS
(a) Billings for the Facility charge shall be based on 12
billings annually.
Formula.
Actual day in reading period x customer facility charge
30 days
PAGE 44
SCHEDULE ECA
ENERGY COST ADJUSTMENT
(Effective 10/07/92)
ENERGY COST ADJUSTMENT
All monthly KWH charges shall be increased or decreased by an
amount equal to "X" cents per KWH, to be known as the energy cost
adjustment (ECA). The ECA shall be computed in the months of April
and October to be applied to the following periods of May through
October and November through April respectively. The City shall in
no case change the energy cost adjustment more than twice in either
of the six (6) months periods The ECA shall be calculated by the
following formula:
Projected energy
cost
for winter months
ECA
(Winter) =
Projected KWH
sales
for winter months
Projected energy
cost
for summer months
ECA
(Summer) =
Projected KWH
sales
for summer months
The
above formula
results in Winter 1992/93 and Summer 1993
ECA's
as follows'
ECA
(Winter) =
1.70G/KWH
ECA
(Summer) =
1.700/KWH
In the event that actual cumulative costs of fuel, variable
costs of Texas Municipal Power Agency (TMPA) energy and purchased
energy (excluding TMPA's fixed charges) are greater than or less
than the cumulative ECA revenues by $1,000,000 during the fiscal
year, the City may recompute the Energy Cost Adjustment and re-
establish an ECA that collects or returns such difference over the
remaining months of the fiscal year. Such change in ECA shall be
applied evenly to all remaining months' ECA.
PAGE 45
SCHEDULE APR
APPLIANCE REBATE
(Effective 10/7/92)
Application/Program Summary
The City of Denton Utility Department is offering cash
payments to customers who purchase and install high efficiency air
conditioners or heat pumps in new or existing residential or
commercial facilities.
The program's objective is to reduce energy demand and con-
sumption, thereby saving customers dollars on their utility bills
and reducing the peak load of the City of Denton's electric system.
Program Guidelines
1 All installations must be for accounts served by the City
of Denton Utility Department and must meet all applicable
national, local, and manufacturers' codes and specifica-
tions.
2. To qualify for a rebate, equipment must be new when in-
stalled.
3. All equipment must be purchased No leased or lease/
purchased equipment will qualify for a cash rebate
4. Installations must be made by licensed contractors and/or
dealers
5. No rebate will be paid on a partial replacement of an air
conditioner The compressor, condenser and the evapora-
tor coil must be replaced to qualify for a rebate
6 Payments for residential central cooling systems, which
include apartments and mobile homes, will be limited to
a capacity based on a minimum of 500 conditioned square
feet per ton.
7. The conditioned area in square feet is required on each
residential central system request for payment
8 The rebate will be paid to the purchaser of the qualify-
ing equipment upon verification of compliance with
program guidelines.
9. Requests for payment must be received by the Director of
Electric Utilities within 60 days of installation.
PAGE 46
10. Equipment and installation are subject to inspection by
the City's Building Inspection Department before final
approval for payment is issued.
11. The Appliance Rebate Program guidelines and payments are
subject to change without notice.
12. The Appliance Rebate Program may be discontinued without
prior notice at any time by the City of Denton.
I. GENERAL PROCEDURES
A Application
To determine who qualifies for a rebate, an appli-
cation for rebate must be completed and sent to the
Director of Electric Utilities within 60 days of
installation of the equipment Participating
dealers have rebate application forms and will
com,)lete these forms for the purchaser It is the
purchaser's responsibility to see that the dealer
completes the form and submits it to the Director
of 'lectric Utilities
B Inspections
Installations of central systems will be inspected
by the City's Building Inspection Department and
must be approved before rebates will be processed.
C. Payments to Participants
Cash payments will be made to the purchaser of the
qualifying equipment. Participating retail equip-
ment dealers will receive a cash payment of $20 per
unit for the sale of window units, central air
conditioning systems, or heat pumps to offset their
cost for properly filling out the applications for
purchasers. Program participants are responsible
for submitting the correct information. The Utili-
ty Department will not issue any additional payment
unless the payment was incorrect due to a mistake
in processing by a City employee
1 The twenty dollar ($20.00) payments to dealers
will be made only if they supply the qualify-
ing equipment to the customer or builder who
is paying for the installation of the equip-
ment. Dealers and purchasers may be denied
payment for failure to follow program guide-
lines such as. failing to supply correct
square footage or SEER/EER figures; installing
equipment which is not new; replacing part of
PAGE 47
a split system; or failure to fill out rebate
forms properly
2. Payments will be made to customers who pur-
chase and install new qualifying equipment.
If a tenant purchases and installs qualifying
equipment, the payment is made to the tenant.
If the owner of rental property purchases and
installs qualifying equipment, the payment is
made to the owner. If the purchaser of a
mobile or custom home selects and pays for a
qualifying unit, the purchaser will receive
the rebate
II. CENTRAL ELECTRIC AIR CONDITIONERS AND HEAT PUMPS
A A new condensing unit with an inside evaporator
coil will qualify if matched, as specified, in the
current issue of the ARI Directory of Certified Air
Conditioners and Air Source Heat Pumps and the unit
meets the minimum ratings as specified in the 1992
Appliance Rebate Program. If the unit is not in
the current ARI Directory, the manufacturer's
latest data approved for publication will be ac-
cepted
If the unit is not in the current ARI Directory or
data approved for publication, the average of the
high and low SEER/EER coil only, not including
blower coil, will be accepted as listed in the
current ARI Directory.
B. Computer simulations may be used if ratings are not
listed in the current ARI Directory, provided the
following criteria are met.
1. Systems using mix -matched coils must meet all
established program guidelines to qualify for
a rebate.
2. The computer simulations must be signed,
certified, and dated by a registered profes-
sional engineer and an officer of the company
making the submittal
3. The engineer who certifies a simulation must
attest to the accuracy of the input data, the
validity of the calculation procedure used,
and that the results are in accordance with
D O.E. approved methodology.
4. A complete set of the input data and an indi-
cation of the source of the data must accompa-
ny the simulated ratings
PAGE 48
A
5 The simulated ratings must be based on the
condensing unit's tested combination as listed
in the current ARI Directory or latest data
approved for publication and identified by the
correct model numbers of both the condensing
unit and coil as listed in the current ARI
Directory.
6. Simulated ratings must not exceed 10 of the
SEER rating of the tested system used as a
base.
7. An open file of computer simulations will be
maintained at the Energy Management Office
Supplying erroneous ratings or data can lead
to disqualification of those involved from
further program participation
Program Capacity and Payment Formula
1 The maximum allowable BTU per hour capacity
eligible for a residential rebate is deter-
mined by dividing the square footage of the
conditioned area by 500 and multiplying by
12,000.
Example The Program Capacity for a 1,500 square
foot house is•
1,500 = 3 0 x 12,000 = 36,000 BTUH
500
The City will pay a rebate on a unit that meets
program efficiency standards and is sized at
36,000 BTUH or less.
2. Actual payment will be determined by dividing the
BTUH of the installed unit (up to, and including
the Program Capacity) by 12,000 and multiplying by
the incentive
The incentive amounts and SEER ratings are refer-
enced on page 5 and are incorporated herein as if
fully set forth at length•
Example A• A person in a 1,500 square foot house
installs a 30,000 BTUH central air
conditioner with a SEER rating of 12.0.
1.500 = 3 x 12,000 = 36,000 Program Capacity
500
PAGE 49
30.000 = 2.5 x $100/ton = $250.00 Rebate Amount
12,000
Example B: A person in a 2,000 square foot house
installs a 60,000 BTUH central air
conditioner with a SEER rating of 12.0.
2,000 = 4 x 12,000 = 48,000 Program Capacity
500
48.000 = 4 x $100/ton = $400 Rebate Amount
12,000
Example C: A person in a 2,000 square foot house
installs a 60,000 BTUH central heat pump
with a SEER rating of 12.0.
2.000 = 4 x 12,000 = 48,000 Program Capacity
500
48,000 = 4 x $100/ton = $400 Rebate Amount
Minimum
SEER/EER
Central Air Conditio in Ratina Incentive
Single Phase (SEER) 12.0 $100/ton*t
Three Phase (EER) 12.0 $100/ton
Central Heat Pumps
Single Phase (SEER) 12.0 $100/ton
Three Phase (EER) 12.0 $100/ton
Room Air Conditioners 10.0 $ 50/unit
Room Heat Pumps 10.0 $ 50/unit
Geothermal Heat Pumps 12.0 $500/unit
* Refer to 111992 Appliance Rebate Program. Methods Used in
Determining Equipment Efficiency and Eligibility"
t For calculation purposes, one ton equals 12,000 BTUH
PAGE 50
SCHEDULE ACR
AIR CONDITIONER CYCLING REBATE
(Effective 10/07/92)
APPLICATION
This schedule is available to any customer of the City of Denton
Utility who is served and billed pursuant to rate schedules R-1,
R-2, GSS/GSL and G1, has a central air conditioning system with a
minimum connected compressor output of 2 5 tons and who agrees to
permit the utility to install a control device to his or her air
conditioning system The device will enable the utility to control
the operation of the air conditioner compressor during periods of
the utility's peak load and emergency conditions. The utility shall
have the right to interrupt service to the compressor unit for
approximately seven and one-half minutes of each thirty minute
interval during peak load conditions Peak load conditions are
defined as being from June 1 through September 30 of each year
TERMS AND CONDITIONS
A customer may apply for this schedule at any time by applying
and entering into a contract with the City of Denton Utility The
contract shall be for a term of one year and shall be renewable for
additional one year terms. Upon approval of the application and
installation of the load reduction device, the customer shall
receive a monthly credit on his or her utility bill, the amount of
which shall be based upon the customer's compressor output (tons)
The start date for receiving credit shall be the date the load
reduction device is installed on the compressor and tested for
proper operation. The amount of the credit is based upon thirty
(30) day billing cycle and prorated according to the start date.
The amount of credit on an eligible customer's bill shall be
determined in the following manner•
Compressor output in Tons
2 5 to 5.0
All over 5.0
Credit per Billing Cycle
$10 00
$ 2.00 per ton
Any credit on a customer's electric bill shall not exceed fifty
percent (50%) of said bill. The Utility shall rebate applicable
credits to customers in the months of June, July, August and
September.
PAGE 51
SCHEDULE VLR
VOLUNTARY LOAD REDUCTION
(Effective 10/07/92)
APPLICATION
This program is available to customers who agree to reduce peak
demand by a minimum of 100KW upon request by the City. Customers
who execute contracts authorizing the City to interrupt power under
the terms and conditions set forth in the attached sample contracts
are eligible for credits on their utility bills
TERMS AND CONDITIONS
Electric utility bill incentives shall be provided as set forth
in the attached sample contract agreements. Customers agreeing to
reduce demand between 2:00 p.m and 7.00 p.m. receive an incentive
of twenty-four dollars ($24.00) per KW demand. Those customers
agreeing to reduce demand between the hours of 3.00 p.m. and 7:00
p.m will receive an incentive of twelve dollars ($12.00) per KW
demand. The customer will be charged according to the current rate
schedule for the months of July, August, and September of each year.
A credit shall be applied to the customer's October bill.
PAGE 52
The
County,
through
(SAMPLE)
AGREEMENT FOR
TEMPORARY REDUCTION IN DEMAND
City of Denton, Texas, a Home Rule City situated in Denton
Texas, hereinafter called "CITY," acting herein by and
its Executive Director of Utilities, Robert E. Nelson and
_ , whose address is ,
hereinafter called "CUSTOMER," hereby mutually agree as follows•
1. APPLICATION: This Agreement is applicable only when
CUSTOMER receives service during the months of July, August, and
September, 1992, when service is subject to load reductions of a
minimum of one -hundred kilowatts (100 KW) upon two hours notifica-
tion by telephone by CITY'S Representative.
The CITY and CUSTOMER have determined the estimated peak
loads for the months of July, August, and September, 1992, for
CUSTOMER to be as follows
Peak Demand.
Service Address•
2. DEFINITIONS: The following definitions shall apply to this
Agreement:
Peak KW Demand: The actual or estimated peak KW usage,
whichever is greater, for the months of July, August, and September,
1992, based on nistorical billing records plus estimates of changes
in load, equipment, etc.
Maximum Demand During Reduction: Customer's maximum (or
peak) demand KW that occurs during reduction(s) requested by the
City
Demand Reduction: Peak KW Demand less Maximum Demand Dur-
ing Reduction.
Utility's Peak Day: The day on which the maximum KW demand
is placed on the entire electrical system
3. SERVICES TO BE PERFORMED• The City has a public interest
in reducing the system peak KW in order to maximize the efficiency
of its utility system and thus, agrees to pay CUSTOMER twenty-four
($24.00) dollars per KW demand for a one time reduction of at least
one -hundred KW (100KW) during the months of July, August, and
September, 1992. CUSTOMER calculates the Maximum Estimated Reduc-
tion in Demand to be an estimated KW The actual reduc-
tion shall be based upon measurements taken by City's representa-
tive.
CITY agrees to monitor its system load and determine if a
reduction in peak KW is required. CITY shall notify CUSTOMER by
PAGE 53
telephone not later than twelve noon of a day if such reduction is
required during that day. CUSTOMER agrees to acknowledge such re-
quest and reduce its load for that day between the hours of 2.00
o'clock p m. and 7:00 o'clock p m.
4 GENERAL BILLING INFORMATION. CUSTOMER will be charged
according to the current rate schedule applicable to the CUSTOMER
for the months of July, August, and September, 1992 A credit shall
be applied to CUSTOMER'S October, 1992 bill, which shall be
calculated as follows'
Peak KW Minimum Demand July -September, 1992 KW
LESS Maximum Demand During Reduction(s) ( xx ) KW
Total Demand Reduction xx KW
x 24.00
Total Credit S xx.xx
5 MISCELLANEOUS. CUSTOMER is granted a one-time exemption
whereby CUSTOMER need not reduce demand by at least 100 KW from its
peak KW demand However, if the CUSTOMER's one-time exemption
occurs on the same date as the Utility's Peak Day, this contract
becomes void and shall terminate immediately If the CUSTOMER
fails, when requested, to reduce its peak demand more than 100 KW on
more than one occasion, this Agreement becomes void and shall
terminate immediately without further notice by the City.
6. TERM. This Agreement is in effect for the period beginning
July 1, 1992 and ending at midnight, September 30, 1992
EXECUTED this day of
CUSTOMER
(Name)
Address
City/State/Zip Code
Telephone Number
Account Number
Meter Number
Contact
, 1992.
CITY OF DENTON, TEXAS
BY:
R. E NELSON, EXECUTIVE
DIRECTOR OF UTILITIES
APPROVED AS TO LEGAL FORM.
DEBRA A DRAYOVITCH, CITY ATTORNEY
BY
PAGE 54
(SAMPLE)
AGREEMENT FOR
TEMPORARY REDUCTION IN DEMAND
The City of Denton, Texas, a Home Rule City situated in Denton
County, Texas, hereinafter called "CITY," acting herein by and
through its Executive Director of Utilities, Robert E Nelson and
, whose address is
hereinafter called "CUSTOMER," hereby mutually agree as follows:
1 APPLICATION. This Agreement is applicable only when
CUSTOMER receives service during the months of July, August, and
September, 1992, when service is subDect to load reductions of a
minimum of one -hundred kilowatts (100 KW) upon two hours notifica-
tion by telephone by CITY'S Representative.
The CITY and CUSTOMER have determined the estimated peak
loads for the months of July, August, and September, 1992, for CUS-
TOMER to be as follows:
Peak Demand: KW
Service Address:
2. DEFINITIONS. The following definitions shall apply to this
Agreement:
Peak KW Demand: The actual or estimated peak KW usage,
whichever is greater, for the months of July, August, and September,
1992, based on historical billing records plus estimates of changes
in load, equipment, etc.
Maximum Demand During Reduction Customer's maximum (or
peak) demand Mi that occurs during reduction(s) requested by the
City
Demand Reduction: Peak KW Demand less Maximum Demand
During Reduction.
Utility's Peak Day: The day on which the maximum KW demand
is placed on the entire electrical system.
3. SERVICES TO BE PERFORMED. The City has a public interest
in reducing the system peak KW in order to maximize the efficiency
of its utility system and thus, agrees to pay CUSTOMER twelve
($12 00) dollars per KW demand for a one time reduction of at least
one -hundred KW (100KW) during the months of July, August, and
September, 1992. CUSTOMER calculates the Maximum Estimated Reduc-
tion in Demand to be an estimated KW The actual reduc-
tion shall be based upon measurements taken by City's representa-
tive
CITY agrees to monitor its system load and determine if a
reduction in peak KW is required. CITY shall notify CUSTOMER by
PAGE 55
telephone not later than twelve noon of a day if such reduction is
required during that day. CUSTOMER agrees to acknowledge such
request and reduce its load for that day between the hours of 3 00
o'clock p.m. and 7.00 o'clock p.m.
4. GENERAL BILLING INFORMATION• CUSTOMER will be charged
according to the current rate schedule applicable to the CUSTOMER
for the months of July, August, and September, 1992 A credit shall
be applied to CUSTOMER'S October, 1992 bill, which shall be
calculated as follows:
Peak KW Minimum Demand July -September, 1992 KW
LESS Maximum Demand During Reduction(s) S xx 1 KW
Total Demand Reduction xx KW
x 12.00
Total Credit $ xx.xx
5. MISCELLANEOUS• CUSTOMER is granted a one-time exemption
whereby CUSTOMER need not reduce demand by at least 100 KW from its
peak KW demand However, if the CUSTOMER's one-time exemption
occurs on the same date as the Utility's Peak Day, this contract
becomes void and shall terminate immediately If the CUSTOMER
fails, when requested, to reduce its peak demand more than 100 KW on
more than one occasion, this Agreement becomes void and shall
terminate immediately without further notice by the City.
6 TERM: This Agreement is in effect for the period beginning
July 1, 1992 and ending at midnight, September 30, 1992.
EXECUTED this day of
CUSTOMER
(Name)
Address
City/State/Zip Code
Telephone Number
Account Number
Meter Number
Contact Person
, 1992
CITY OF DENTON, TEXAS
BY.
R E. NELSON, EXECUTIVE
DIRECTOR OF UTILITIES
APPROVED AS TO LEGAL FORM:
DEBRA A. DRAYOVITCH, CITY ATTORNEY
BY
PAGE 56
SECTION II. That the Executive Director of Utilities is hereby
authorized to execute agreements with electric utility customers in
the form and type set forth herein as an attachment to Schedule VLR.
SECTION III. That if any section, subsection, paragraph,
sentence, clause, phrase or word in this ordinance, or application
thereof to any person or circumstances is held invalid by any court
of competent jurisdiction, such holding shall not affect the
validity of the remaining portions of this ordinance, and the City
Council of the City of Denton, Texas, hereby declares it would have
enacted such remaining portions despite any such invalidity.
SECTION IV. That the Schedule of Rates herein adopted shall be
effective, charged and applied to all energy consumption occurring
on or after October 7, 1992.
PASSED AND APPROVED this the l0 day of O, 1992.
BOB CASTLEBERRY, MAYOR
ATTEST.
JENNIFER WALTERS, CITY SECRETARY
DEBRA A.
DRAYOVITCH,
CITY ATTORNEY
PAGE 57