Loading...
HomeMy WebLinkAbout1992-069ALL001AD\1705 5 3 ORDINANCE NO / c2'C) 9 AN ORDINANCE OF THE CITY OF DENTON, TEXAS, AMENDING THE SCHEDULE OF ELECTRIC RATES BY ADOPTING AN AMENDED SCHEDULE TGS (GENERAL SERVICE TIME OF USE RATE), AND PROVIDING FOR AN EFFECTIVE DATE THE COUNCIL OF THE CITY OF DENTON HEREBY ORDAINS SECTION I That the Schedule of Rates for electrical services, as adopted by Ordinance No 90-168, is amended by amending the provisions of Schedule TGS (General Service Time of Use Rate), a copy of which is attached hereto in Exhibit "A" and incorporated by reference herein SECTION II That this ordinance shall become effective May 1, 1992 PASSED AND APPROVED this the4',-V& day of 1992 ATTEST JENNIFER WALTERS, CITY SECRETARY BY APPROVED AS TO LEGAL FORM DEBRA A DRAYOVITCH, CITY ATTORNEY BY� EXHIBIT "A" SCHEDULE TGS GENERAL SERVICE TIME OF USE (TGS) (Effective Applicable to any commercial and industrial user for all electric service supplied at one point of delivery and measured through one meter who has peak electrical loads during off peak hours Customers electing to utilize the TGS rate may change to this rate only during the month of June and must remain on this rate for a minimum of twelve (12) continuous billing months Not applicable to resale service in any event, nor to temporary, standby or supplementary service except in conjunction with applicable rider (1) Customer Facility Charge $25 00/30 days Single Phase $30 00/30 days Three Phase (2) On -Peak Demand Charge $12 50/KW of On -Peak Demand (3) System Demand Charge (4) Energy Charge (5) Energy Cost Adjustment MINIMUM BILLING $ 4 00/KW of System Demand $ 01/KWH Per Schedule ECA The minimum monthly bill shall be the sum of the Customer Facility Charge, the On -Peak Demand Charge, and the System Demand Charge, but not less than 70W of the maximum monthly total demand charge for any month during the preceding months of May through October Secondary service available to commercial and industrial customers The City will supply single-phase service (or three-phase service if available at theipoint of delivery) at sixty (60) cycles and at any standard voltages available from the City's distribution system through one standard transformation Where service of the type desired by the customer is not already available at the point of service, special contract arrangements between the City and the customer may be required prior to its being furnished The On -Peak Demand shall be the maximum KW demand supplied during the fifteen (15) minute period of maximum use during the on peak hours as recorded by the City's demand meter and adjusted for power factor The minimum monthly bill for On Peak Demand shall be one hundred percent (100W) of the maximum on -peak demand, similarly determined during the previous billing months of June through September in the twelve (12) months ending with the current month he On -Peak Demand will be billed every month The System Demand shall be the maximum KW demand supplied during the fifteen (15) minute period of maximum use as recorded by the City's demand meter and adjusted for power factor, but not less than one hundred percent (100%) of the maximum system demand similarly determined during the previous billing months of June through September in the twelve (12) months ending with the current month The City reserves the right to determine the power factor of the customer's installation served during the period of maximum demand or by measurement of the average power factor for the monthly billing period If the power factor is below ninety percent (90*), on -peak and average demand for the demand for billing purposes will be determined by multiplying the unadjusted billing demand by ninety percent (90t) and dividing by the determined power factor The City's on -peak hours, for the purpose of this rate schedule, are designated as being from 1 00 P M to 8 00 P M each Monday through Friday, starting on June 1 and continuing through September 30 each year The City's on -peak hours may be changed from time to time and the customer will be notified twelve (12) months prior to such changes becoming effective The City's off-peak hours, schedule, shall be all hours not SUPPL•EMEM " nnWER RT11 R for the purpose of this rate designated as on -peak hours Customers requesting standby or supplementary power shall be allowed service under this rate schedule, however, the determination of system demand shall be adjusted to read The system aemand shall ne t"e sum of the maximum KW aemara supplied during the fifteen (15) minute period of maximum use as recorded by the City's demand meter plus the KW nameplate ratirg(s) of the customer's generator(s) In the event of the customer s generator(s) is/are off line at tre time of the establishment of tl,e maximum system demand, the KW nameplate rating of the generator(s) unavailable for service shall be removed from the determination of the system demand In no event shall the system demand be less than seventy percent (70U of the maximum system demand similarly determined during the previous billing months of June through September in the twelve (12) months ending with the current month All service which requires special facilities in order to meet the customer's service requirements shall be provided subject to special facilities rider (a) Billing for the Facility Charge shall be based on 12 billings annually using the following formula Actual day in reading period X Customer Charge 30 (b) Billing for demand shall be calculated on a 30-day-per- month basis and pro -rated for longer or shorter billing periods using the following formula Actual days in reading period x KW Demand x Rate 30 A charge per M of energy taken for fuel cost calculated in accordance with Schedule E C A Bills are due when rendered, and become past due if not paid within fifteen (is) calendar days from date of issuance TGSRATE 0