HomeMy WebLinkAbout1987-0271246L
4730U
NOTE THIS ORDINANCE HAS BEEN AMENDED BY ORDINANCE NO 88-110
NOTE THIS ORDINANCE HAS BEEN AMENDED BY ORDINANCE NO 88-098
NO U / -01027
AN ORDINANCE ADOPTING NEW RATE SCHEDULES FOR ELECTRICAL SERVICES,
PROVIDING FOR A SEVERABILITY CLAUSE, AND PROVIDING FOR AN
EFFECTIVE DATE
THE COUNCIL OF THE CITY OF DENTON HEREBY ORDAINS
SECTION I
That the Schedule of Rates for electrical services as
provided for 1n Chapter 25 of the Code of Ordinances, are hereby
established as follows
ARTICLE I
ELECTRIC RATE SCHEDULES PAGE
2
RI
Residential Service Rate
4
R2
Residential Service Rate
LP
Large Primary Commercial $ Industrial
Lighting and Power Service Rates
6
8
GP
General Service Primary
GS
General Service Commercial
10
12
RW
Religious Worship
G1
Local Government Lighting & Power Service Rate
(City, County, Independent School District)
14
TR
Residential Time of Use Rate
16
18
TP
Primary Time of Use Rate
TG
General Service Time of Use Rate
20
22
G2
Street Lighting
23
G3
Traffic Signal Lighting
Di
Dusk -to -Dawn Lighting (Security Light)
24
T1
Temporary Service Schedule
26
2830
P1
Interruptible Primary Service
AF
Athletic Field
32
h,CA Energy Cost Adjustment
UPS Uninterruptible Power Supply
33
SCHEDULE R-1
RESIDENTIAL SERVICE
APPLICATION
Applicable to all electric service used for residential pur-
poses in a single family dwelling or an individually metered
apartment, supplied at one point of delivery and measured through
one meter where usage is not in excess of 700 KWH per 30-day
month during the billing months MAY through OCTOBER If usage in
any such month exceeds 700 KWH, billing will be rendered that
month under Rate Schedule R-2 and thereafter for a period
extending through the 12 billing months of the next year ending
with the October billing Annually, in November, the customer may
again qualify for the R-1 rate provided that consumption has not
exceeded 700 KWH per 30-day month during the previous six summer
months
Where individual dwelling units are being served through the
same meter as of the effective date of this rate schedule and the
KWH in the billing months of MAY through OCTOBER exceed 700 KWH
times the number of dwelling units, the billing for that month
and thereafter will be rendered under Rate Schedule R-2
NET MONTHLY RATE
(1) Customer Facility Charge $5 50/30 days
(2) Energy Charge 4 65¢/KWH
(3) Energy Cost Adjustment Schedule ECA
MINIMUM BILLING
$5 50/30 days
TYPE OF SERVICE
The City will supply single-phase service at any standard
voltages available from the City's distribution system through
one standard transformation
PAYMENT
Bills are due when rendered, and become past due if not paid
within 15 calendar days from date of issuance
PAGE 2
SPECIAL FACILITIES
All services which require special facilities in order to
meet customer's service requirements shall be provided subject to
the special facilities rider
PRORATION OF UTILITY BILLS
Billing for the Facility charge shall be based on 12 billings
annually
Formula
Actual days in reading period x customer charge
30
ENERGY COST ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule E C A
PAGh 3
SCHEDULE R-2
RESIDENTIAL SERVICE
APPLICATION
Applicable to any customer for all electric service used for
residential purposes in an individual private dwelling or an
individually metered apartment, supplied at one point of delivery
and measured through one meter Also applicable to any customer
heating with electric energy, resistance or heat pump
Not applicable to resale service in any event, nor to
temporary, standby, or supplementary service except in
conjunction with applicable rider
NET MONTHLY RATE
WINTER
SUMMER
Billing months of Billing months of
Nov through April May through Oct
(1) Customer Facility Charge
Single Phase
Three Phase
(2) Energy Charge
First 1,000 KWH
All additional KWH
First 3,000 KWH
All additional KWH
$ 6 50/30 days
$11 00/30 days
5 150/KWH
4 654/KWH
(3) Energy Cost Adjustment Schedule ECA
MINIMUM BILLING
Single Phase
Three Phase
TYPE OF SERVICE
$ 6 50/30 days
$11 00/30 days
$ 6 50/30 days
$11 00/30 days
5 65¢/KWH
6 154/KWH
Schedule ECA
$ 6 50/30 days
$11 00/30 days
The City will supply single-phase service (or three-phase
service if available at the point of delivery) at sixty (60)
cycles and at any standard voltages available from the City's
distribution system through one standard transformation Where
service of the type desired by the customer is not already
available at the point of service, special contract arrangements
between the City and the customer may be required prior to its
being furnished
PAGE 4
PAYMENT
Bills are due when rendered, and become past due if not paid
within 15 calendar days from date of issuance
SPECIAL FACILITIES
All services which require special facilities in order to meet
customer's service requirements shall be provided subject to the
special facilities rider
PRORATION OF UTILITY BILLS
(a) Billing for the Facility charge shall be based on 12
billings annually
Formula
Actual days in reading period x customer charge
3�
(b) Billing for the energy charge shall be based on 30 days
per month to determine the KWH consumption to be charged
to each rate block
Formula
Actual days in reading period x KWH in rate block x Rate per
30 KWH in rate block
ENERGY COST ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule E C A
PAGE 5
SCHEDULE LP
LARGE PRIMARY
APPLICATION
LP Rate applicable to any customer having a minimum demand of
750 KW for all electric service supplied at one point of delivery
and measured through one meter, with customer providing all
facilities necessary to receive primary voltage service
Not applicable to resale service in any event, nor to
temporary, standby or supplementary service except in conjunction
with applicable rider
NET MONTHLY RATE
(1) Customer Facility Charge
(2) Demand Charge
(3) Energy Charge
(4) Energy Cost Adjustment
MINIMUM BILLING
$45 00 per 30 days
$5 50 per KW of demand
2 954/KWH for all KWH
Schedule ECA
An amount equal to the demand charge as calculated below
but not less than seventy percent (70%) of the maximum monthly
demand charge for any month during the preceding months of May
through October plus $45 00 per 30 day Billing
TYPE OF SERVICE
LP rate primary voltage service (transformation equipment
owned by customer) is available to any customer who has a minimum
demand of 750 KW * Primary service is rendered at one point on
the customer's premises at a nominal voltage of 13,200 volts
*Customers on primary service prior to February 3, 1987, are
not required to meet the 750 KW requirement
The primary voltage service customer shall own, operate, and
maintain all facilities necessary to receive three phase primary
voltage service and all transformation facilities required for
conversion to utilization voltage The City shall own, operate
and maintain all metering facilities, either at primary or
secondary voltage, at the City's option Where the City elects to
meter at secondary voltage, two percent shall be added to the
PAGE 6
demand charge, the energy charge and the energy cost adjustment
charge to account for transformer losses
PAYMENT
Bills are due when rendered, and become past due if not paid
within 15 calendar days from date of issuance
DETERMINATION OF DEMAND
The demand shall be the KW supplied during the 15-minute
period of maximum use during the current month as determined by
City's demand meter, but not less than 70% of the maximum monthly
KW similarly determined during the previous billing months of MAY
through OCTOBER in the 12 months ending with the current month
POWER FACTOR
The City reserves the right to make tests to determine eligi-
bility for the LP rate, and to determine the power factor of the
customer's installation served during periods of maximum demand or
by measurement of the average power factor for the monthly billing
period If the power factor is below ninety percent, the demand
for billing purposes will be determined by multiplying the uncor-
rected KW billing demand by 90% and dividing by the determined
power factor
SPECIAL FACILITIES
All services which require special facilities in order to meet
customer's service requirements shall be provided subject to the
special facilities rider
PRORATION OF UTILITY BILLS
(a) Billing for the Facility charge shall be based on 12
billings annually
Formula
Actual days in reading period x customer charge
3U
PAGE 7
(b) Billing for demand shall be calculated on a 30 day per
month basis and prorated for longer or shorter billing
periods
Formula
Actual days in reading period x KW demand x Rate
3 ays
ENERGY COST ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule E C A
PAGE 8
SCHEDULE GP
GENERAL SERVICE PRIMARY
APPLICATION
GP Rate applicable to any customer having a minimum demand of
750 KW for electric service supplied at one point of delivery and
measured through one meter, with the City providing and owning all
facilities and transformation equipment necessary to receive
primary voltage service
Not applicable to resale service in any event, nor to tempo-
rary, standby or supplementary service, except in conjunction with
applicable rider
NET MONTHLY RATE
(1) Facility Charge
(2) Demand Charge
(3) Energy Charge
(4) Energy Cost Adjustment
MINIMUM BILLING
$4S 00/30 days
$5 75/KW
3 1¢/KWH
Current ECA
An amount equal to the demand charge as calculated below but
not less than seventy percent (70%) of the maximum monthly demand
charge for any month during the preceding months of May through
October, inclusive, plus $45 00 per 30 day billing
TYPE OF SERVICE
For GP primary voltage service, the City will supply three-
phase service at sixty (60) cycles and at any standard voltages
available from the City's distribution system To be eligible for
GP service, customers must have a minimum demand of 750 KW *
Where required facilities are not already available at the point
of service, special contractual arrangements between the City and
the customer will be required prior to its being furnished
*Customers on primary service prior to February 3, 1987, are
not required to meet the 750 KW requirement
PAYMENT
Bills are due when rendered, and become past due if not paid
within 15 days from date of issuance
PAGE 9
DETERMINATION OF DEMAND
The demand shall be the KW supplied during the 15-minute
period of maximum use during the current month as determined by
City's demand meter, but not less than 70% of the maximum monthly
KW similarly determined during the previous billing months of MAY
through OCTOBER in the 12 months ending with the current month
POWER FACTOR
The City reserves the right to make tests to determine the
power factor of the customer's installation served during periods
of maximum demand or by measurement of the average power factor
for the monthly billing period If the power factor is below
ninety percent, the demand for billing purposes will be determined
by multiplying the uncorrected KW billing demand by 90% and
dividing by the determined power factor
SPECIAL FACILITIES
All services which require special facilities in order to meet
the customer's service requirements shall be provided subject to
special facilities rider
PRORATION OF UTILITY BILLS
(a) Billing for the Facility charge shall be based on 12
billings annually
Formula
Actual days in reading period x customer charge
3
(b) Billing for demand shall be calculated on a 30 day per
month basis and prorated for longer or shorter billing
periods Formula
Actual days in reading period x KW demand x Rate
30 days
ENERGY COST ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule E C A
PAGE 10
SCHEDULE GS
GENERAL SERVICE
APPLICATION
Applicable to any commercial and industrial users for all
electric service supplied at one point of delivery and measured
through one meter
Not applicable to resale service in any event, nor to
temporary, standby or supplementary service except in conjunction
with applicable rider
NET MONTHLY RATE
(1) Customer Facility Charge
Single Phase
Three Phase
(2) Demand Charge
(3) Energy Charge
First 700 KWH
All KWH over 700
(4) Energy Cost Adjustment
MINIMUM BILLING
$10 00 per 30 days
$15 00 per 30 days
$ 5 75 per KW (first 5 KW not
billed)
7 500/KWH
3 50¢/KWH
Current ECA Schedule
An amount equal to the demand charge as calculated below but
not less than seventy percent (70%) of the maximum monthly demand
charge for any month during the preceding months of May through
October plus $10/ month for single phase or less than $15/month
for three phase, per 30 day billing
TYPE OF SERVICE
Secondary service available to commercial and industrial
customers
The City will supply single-phase service (or three-phase
service if available at the point of delivery) at sixty (60)
cycles and at any standard voltages available from the City's
distribution system through one standard transformation Where
service of the type desired by the customer is not already
PAGE 11
available at the point of service, special contract arrangements
between the City and the customer may be required prior to its
being furnished
PAYMENT
Bills are due when rendered, and become past due if not paid
within 15 calendar days from date of issuance
DETERMINATION OF DEMAND
The demand shall be the KW supplied during the 15-minute
period of maximum use during the current month as determined by
City's demand meter, but not less than 70% of the maximum monthly
KW similarly determined during the previous billing months of MAY
through OCTOBER in the 12 months ending with the current month
The KW demand used for billing shall be adjusted by subtracting 5
KW The adjusted KW demand will subsequently be used for billing
for the demand portion of the utility bill In no case, shall
billed demand be less than 0 KW
In cases where the connected load is constant, the City may,
at it's option, estimate the KW demand For neon signs, one volt
ampere shall be considered the equivalent of 3/4 watt
POWER FACTOR
The City reserves the right to make tests to determine the
power factor of the customer's installation served during periods
of maximum demand or by measurement of the average power factor
for the monthly billing period If the power factor is below
ninety percent, the demand for billing purposes will be determined
by multiplying the uncorrected KW billing demand by 90% and
dividing by the determined power factor
SPECIAL FACILITIES
All services which require special facilities in order to meet
customer's service requirements shall be provided subject to the
special facilities rider
PRORATION OF UTILITY BILLS
(a) Billing for the Facility charge shall be based on 12
billings annually
Formula
Actual days in reading period x customer charge
30
PAGE 12
Billig for
nd shall be
n a
er
(b) monthn bass and prorated for longer calculated oorshorts billing
periods
Formula
Actual days in reading period x adjusted KW demand x Rate
30 ays
ENERGY COST ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule E C A
PAGE 13
SCHEDULE RW
RELIGIOUS WORSHIP
APPLICATION
Applicable to any facility used primarily for religious wor-
ship, education and meeting Vernon's Annotated Texas Statutes
guidelines
e for ry tax exemption as a religious
organization
NET MONTHLY BILLING
(1) Facility Charge
Single Phase
Three Phase
(2) Energy Charge
First 700 KWH
All over 700 KWH
(3) Demand Charge
(4) Energy Cost Adjustment
$10 00/30 days
$15 00/30 days
$ 7 50O/KWH
$ 3 25¢/KWH
$ 3 75/KW (first 5 KW not
billed)
Current ECA Schedule
MINIMUM BILLING
An amount equal to the demand charge as calculated below but
not less than fifty percent (50$) of the maximum monthly demand
charge for any month during the preceding months of May through
October plus $10/ month or in le phase service or $15/month for
three phase service, p day g
TYPE OF SERVICE
The City will supply single-phase service (or three-phase
service if available at the point of delivery) at sixty (60)
cycles and at any standard voltages available from the City's
distribution system through one standard transformation Where
service of the type desired by the customer is not already
available at the point of service, special contract arrangements
between the City and the customer may be required prior to its
being furnished
PAYMENT
Bills are due when rendered, and become past due if not paid
within 15 calendar days from date of issuance
PAGE 14
DETERMINATION OF DEMAND
The demand shall be the KW supplied during the 15-minute
period of maximum use during the current month as determined by
City's demand meter, but not less than 50% of the maximum monthly
KW similarly determined during the previous billing months of MAY
through OCTOBER in the 12 months ending with the current month
The KW demand used for billing shall be adjusted by subtracting 5
KW The adjusted KW demand will subsequently be used for billing
for the demand portion of the utility bill In no case, shall
billed demand be less than 0 KW
SPECIAL FACILITIES
All services which require special facilities in order to meet
customer's service requirements shall be provided subject to the
special facilities rider
PRORATION OF UTILITY BILLS
Billing for consumption and demand shall be calculated on a
30-day basis and prorated for longer or shorter billing periods
(a) Billing for the Facility charge shall be based on 12
billings annually
Formula
Actual days in reading period x customer charge
30
per
(b) Billimonthg for basis andnd shall be prorated forcalculated
oron a shorte0r billing
periods
Formula
Actual days in reading period x KW demand x Rate
30 days
ENERGY COST ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule E C A
PAGE 15
SCHEDULE G-1
LOCAL GOVERNMENT
APPLICATION
Applicable to any local City, County or School Districts for
all electric service supplied at one point of delivery and
measured through one meter
Not applicable to resale service in any event, nor to
temporary, standby or supplementary service except in conjunction
with applicable rider
NET MONTHLY RATE
(1) Customer Charge
Single Phase $10 00 per 30 days
Three Phase $15 00 per 30 days
(2) Demand Charge $
4 50 per KW of demand
(3) Energy Charge $ 3 250 per KWH for all KWH
(4) Energy Cost Adjustment Current ECA Schedule
MINIMUM BILLING
An amount equal tothe de(50%) charge
theamaximumcalculated
monthlyldemand
but
not less than fifty percent
charge for any month during the preceding months of May through
Octber plus $100/ month ase
$15o00/month for three phase fservice,or eperh30 day billing vice or less than
billing period
TYPE OF SERVICE
The City will supply single-phase service (or three-phase
service if available at the point of delivery) at sixty (60)
cycles and at any standard voltages available from the City's
distribution system through one standard transformation Where
service of the type desired by the customer is not already
available at the point of service, special contract arrangements
between the City and the customer may be required prior to its
being furnished
PAYMENT
Bills rendered,
te and
i suance past due if not paid
within 15 cale dar days from daof
PAGE 16
DETERMINATION OF DEMAND
ofe maximums
ax hall
during Ktuhesupplied
currentduring
monththe
aslsdeterminedperiod demand be the by
City's demand meter
POWER FACTOR
The City reserves the right to make tests to determine ltthe
ods
power factor of the customer's installation served during p
of maximum demand or by measurement of the average power factor
for the monthly billing period If the power factor is below
ninety percent, thedemand uncorrectedilKWngbillingeSwill dem demand b by and
by multiplying the
dividing by the determined power factor
SPECIAL FACILITIES
All services which require special facilities in order to meet
customer's service requirements shall be provided subject to the
special facilities rider
PRORATION OF UTILITY BILLS
(a) Billing for the Facility charge shall be based on 12
billings annually
Formula
Actual days in reading period x customer charge
30
n a day er
(b) monthn basis
Billig as and prorated fornd shall be longer calculated oorshorts billing
periods
Formula
Actual days in readin eriod x KW demand x Rate
'5U Gays
ENERGY COST ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule E C A
PAGE 17
SCHEDULE TR
RESIDENTIAL TIME OF USE RATES
APPLICATION
Applicable to any customer for all electric service used for
residential purposes in an individual private dwelling or an indi-
vidually metered apartment, supplied at one point of delivery and
measured through one meter Customers applying for TR rate must
remain on this rate for 12 continuous billing periods
Not applicable to resale service in any event, nor to
temporary, standby, or supplementary service except in conjunction
with applicable rider
NET MONTHLY RATE
(1) Customer Facility Charge $10 00/30 days
(2) Energy Charge
Billing months of June through September
12 00 Noon through 8 00 p m (Peak Period) 10 250/KWH
(Weekdays and excluding all City of Denton
Holidays)
All other hours (Off Peak Period) 4 54/KWH
Billing months of October through May
All KWH 4 5¢/KWH
(3) Energy Cost Adjustment Schedule ECA
MINIMUM BILLING
Facility Charge
TYPE OF SERVICE
The City will supply single-phase service (or three-phase
service if available at the point of delivery) at sixty (60)
cycles and at any standard voltages available from the City's
distribution system through one standard transformation Where
service of the type desired by the customer is not already
available at the point of service, special contract arrangements
between the City and the customer may be required prior to its
being furnished
PAGE 18
PAYMENT
Bills are due when rendered, and become past due if not paid
within 15 calendar days from date of issuance
SPECIAL FACILITIES
All services which require special facilities in order to meet
customer's service requirements shall be provided subject to the
special facilities rider
PRORATION OF UTILITY BILLS
Billing for the Facility charge shall be based on 12 billings
annually
Formula
Actual days In reading period x customer charge
30
ENERGY COST ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule E C A
PAGE 19
SCHEDULE TP
PRIMARY TIME OF USE RATES
APPLICATION
Applicable to approved electric service required for secondary
distribution service at voltage levels not to exceed 69,000 volts,
and billing demand equal to or greater than 750 KW Customers
applying for TP rate must remain on this rate for 12 continuous
billing periods
NET MONTHLY RATE
(1) Facility Charge $60 00/30 days
(2) Energy Charge
Billing months of June through September
12 00 Noon through 8 00 p m (Peak Period) 12 00�/KWH
(Weekdays and excluding all City of Denton
Holidays)
All other hours (Off Peak Period) 3 504/KWH
Billing months of October through May
All KWH 3 50¢/KWH
(3) Demand Charge No demand charge
(4) Energy Cost Adjustment Schedule ECA
MINIMUM BILLING
Facility Charge
TYPE OF SERVICE
At the City's available primary voltage and phase
PAYMENT
Bills are due when rendered, and become past due if not paid
within 15 calendar days from date of issuance
PAGE 20
SPECIAL FACILITIES
All services which require special facilities in order to meet
the customer's service requirements shall be provided subject to
special facilities rider
PRORATION OF UTILITY BILLS
Billing for the Facility charge shall be based on 12 billings
annually
Formula
Actual days in reading period x customer charge
ENERGY COST ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule E C A
PAGE 21
SCHEDULE TG
GENERAL SERVICE TIME OF USE RATES
APPLICATION
Applicable to approved electric service required for secondary
distribution service at voltage levels not to exceed 480 volts
Customers applying for TG rate must remain on this rate for 12
continuous billing periods
NET MONTHLY RATE
(1) Facility Charge
Single Phase
Three Phase
$10 00/30 days
$20 00/30 days
(2) Energy Charge
Billing months of June through September
12 00 Noon through 8 00 p m (Peak Period) 10 25�/KWH
(Weekdays and excluding all City of Denton
Holidays)
All other hours (Off Peak Period) 4 54/KWH
Billing months of October through May
All KWH 4 5¢/KWH
(3) Demand Charge No demand charge
(4) Energy Cost Adjustment Schedule ECA
MINIMUM BILLING
Facility Charge
TYPE OF SERVICE
Secondary service available to commercial and industrial
customers The City will supply single-phase service (or three-
phase service if available at the point of delivery) at sixty (60)
cycles and at any standard voltages available from the City's
distribution system through one standard transformation Where
service of the type desired by the customer is not already
available at the point of service, special contract arrangements
PAGE 22
between the City and the customer may be required prior to its
being furnished
PAYMENT
Bills are due when rendered, and become past due if not paid
within 15 calendar days from date of issuance
SPECIAL FACILITIES
All services which require special facilities in order to meet
customer's service requirements shall be provided subject to the
special facilities rider
PRORATION OF UTILITY BILLS
Billing for the Facility charge shall be based on 12 billings
annually
Formula
Actual days in reading period x customer charge
30
ENERGY COST ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule E C A
PAGE 23
SCHEDULE G-2
STREET LIGHTING
APPLICATION
Applicable to all street lighting owned and maintained by the
City of Denton
NET MONTHLY RATE
(1) Facility Charge
100W Sodium Vapor
250W Sodium Vapor
400W Sodium Vapor
175W Mercury Vapor
250W Mercury Vapor
400W Mercury Vapor
1000W Mercury Vapor
TYPE OF SERVICE
(2) Energy Cost Adjustment
Current ECA x Monthly Bulb Wattage Factor
Bulb Wattage Factor
$ 4
50
48
KWH
$ 6
50
105
KWH
$ 8
25
1559
KWH
$ 5
25
70
KWH
$ 6
25
98
KWH
$ 8
00
153
KWH
$14
75
380
KWH
The City will supply single-phase service (or three-phase ser-
vice if available at the point of delivery) at sixty (60) cycles
and at any standard voltages available from the City's distribution
system through one standard transformation Where service of the
type desired by the customer is not already available at the point
of service, special contract arrangements between the City and the
customer may be required prior to its being furnished
PAYMENT
Bills are due when rendered, and become past due if not paid
within 15 calendar days from date of issuance
PRORATION OF UTILITY BILLS
a) Billing for the Facility charge shall be based on 12
billings annually
Formula
Actual days in reading period x customer charge
38
PAGE 24
ENERGY COST ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule E C A
PAGE 25
SCHEDULE G-3
TRAFFIC SIGNAL LIGHTING
APPLICATION
Applicable to State and Local Government agencies that install
and maintain their own street lights and traffic signals
NET MONTHLY RATE
All KWH
4 90¢ per KWH
TYPE OF SERVICE
At the City's available secondary voltage and phase
PAYMENT
Bills are due when rendered, and become past due if not paid
within 15 calendar days from date of issuance
MAINTENANCE CHARGE
Maintenance expenses billed at cost
SPECIAL FACILITIES
All services which require special facilities in order to meet
customer's service requirements shall be provided subject to the
special facilities rider
ENERGY COST ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule E C A
PAGE 26
SCHEDULE D-1
DUSK TO DAWN LIGHTING
APPLICATION
Applicable to any customer within the area served by the
City's electric distribution system for outdoor area lighting when
such lighting facilities are operated as an extension of the
City's distribution system
NET MONTHLY RATE
(1) Facility Charge (2) Energy Cost Adjustment
Current ECA x monthly bulb wattage factor
Bulb Wattage Factor
A 100W
Sodium Vapor
$
6
20
48
KWH
E 250W
Sodium Vapor
$
8
20
105
KWH
F 400W
Sodium Vapor
$10
10
159
KWH
B 175W
Mercury Vapor
$
5
45
70
KWH
C 250W
Mercury Vapor
$
6
10
98
KWH
D 400W
Mercury Vapor
$
6
85
153
KWH
TYPE OF SERVICE
The City shall furnish, install, maintain and deliver electric
service to automatically controlled, mercury or sodium vapor
lighting fixtures conforming to the City's standards and subject
to its published rules and regulations
Where necessary for proper illumination or where existing
poles are inadequate, the City will install or cause to be instal-
led, one (1) pole for each installed light, at a distance not to
exceed eighty (801) feet from said existing lines, at no charge to
the customer Each additional pole span shall not exceed a span
spacing of one hundred (1001) feet Additional poles required to
install a light in a customer's specifically desired location, and
not having a light installed on same, shall bear the cost
PAYMENT
Bills are due when rendered, and become past due if not paid
within 15 calendar days from date of issuance
PAGE 27
TERM OF CONTRACT
A two (2) year contract shall be agreed to and signed by each
customer desiring Dusk -to -Dawn Lighting Service authorizing fixed
monthly charges, which may be reviewed annually, and to be applied
to the monthly municipal utilities bill In the event that a
customer desired the removal of the unit or discontinuance of the
service prior to completion of two (2) years, the remainder of the
contract period shall become due and payable After the end of
the initial two (2) year contract, service shall continue on a
month -to -month basis and may be cancelled by either party upon
thirty (30) days notice
SPECIAL FACILITIES
All service which requires special facilities in order to meet
the customer's service requirements shall be provided subject to
special facilities rider
PRORATION OF UTILITY BILLS
Billing for the Facility charge shall be based on 12 billings
annually
Formula
Actual days in reading period x customer charge
30
ENERGY COST ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule E C A
PAGE 28
SCHEDULE T-1
TEMPORARY SERVICE
APPLICATION
Applicable when a customer requests electric service on a
short term or temporary basis
NET MONTHLY RATE
(1) Facility Charge
Single Phase
Three Phase
(2) Energy Charge
(3) Energy Cost Adjustment
MINIMUM BILLING
$10 00/30 days
$15 00/30 days
$ 6 504/KWH
Current ECA Schedule
Facility charge
TYPE OF SERVICE
At the City's available secondary supply
PAYMENT
Bills are due when rendered, and become past due if not paid
within 15 calendar days from date of issuance
ADDITIONAL TEMPORARY SERVICE CHARGES
Labor (Regular Time) $40 40 minimum up to 1 hour
$40 40 for each additional hour (to be
measured to the nearest one -quarter hour)
Labor (Overtime) $60 20 minimum up to 1 hour
measu0red or to each
cthe additionalh
our (to be
nearest one -quarter
hour) Premium time to be added where
applicable
Transportation To be billed by hours or miles, as
applicable, according to the estimated
cost of operating the equipment
PAGE 29
Material Material that cannot be salvaged to be
billed at Stores cost plus 25% and
applicable sales tax
At the time a temporary service is
removed or converted, any loss in the
material installed due to negligence or
willful action by the customer will be
billed separately to customer at Stores
cost plus 25% and sales tax
SPECIAL FACILITIES
All services which require special facilities in order to meet
s shall
special tofacilitiesvirider quirSee ntSection 25-23(e)desubject for standard
requirements
PRORATION OF UTILITY BILLS
Billing for the Facility charge shall be based on 12 billings
annually
Formula
Actual days in reading period x customer charge
30
ENERGY COST ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule E C A
PAGE 30
SCHEDULE PI
INTERRUPTIBLE PRIMARY SERVICE
APPLICATION
Applicable to all customers taking primary service at a firm
power load exceeding 5,000 KVA during the months of June, July,
August and September and is, by contract, provided service subject
to load interruptions
NET MONTHLY CHARGE
(1) Facility Charge
(2) Energy Charge
(3) Demand Charge
(Estimated transmission firm)
$45 00/30 days
2 6¢/KWH
$5 00/KW
(4) Energy Cost Adjustment Current ECA Schedule
PAYMENT
Bills are due when rendered, and become past due if not paid
within 15 calendar days from date of issuance
MINIMUM BILLING
An amount equal to the demand charge as calculated below but
not less than seventy percent (70%) of the maximum monthly KW
similarly determined during the previous billing months of MAY
through OCTOBER in the 12 months ending with the current month,
nor LESS than 750 KW
TYPE OF SERVICE
Primary voltage service (transformation equipment owned by
customer) is available to any customer with a 12-month minimum
monthly demand of 750 KW or greater Primary service rendered at
one point on the customer's premises at a nominal voltage of
13,200 volts or 69,000 volts three-phase at the option of the
utility
The primary voltage service customer shall own, operate, and
maintain all facilities necessary to receive three phase primary
voltage service and all transformation facilities required for
conversion to utilization voltage The City shall own, operate
and maintain all metering facilities, either at primary or
secondary voltage, at the Utility's option Where the City elects
PAGE 31
to meter at secondary voltage, two percent shall be
added
ad7u o the
demand charge, the energy charge and the energy
cost ent
charge to account for transformer losses
DETERMINATION OF DEMAND
The demand shall be the KW supplied during the 15-minute
period of the
City's demand lmeter ,s but unot g current
less than70% month
tthe maximumm monthly
months of
throughl OCTOBERt in ithe during2m months ending uwith billing
current month, h
nor LESS than 750 KW
POWER FACTOR REQUIREMENTS AND ADJUSTMENTS
The City reserves the right to make tests to determine the
power factor of the user's installation served hereunder during
periods of maximum demand for the monthly billing periods Should
the power factor so determined be below ninety (90%) percent, the
demand for billing purposes will be determined by multipldiv ng ding
the
uncorrected KW billing demand by ninety (90%) percent
by the determined power factor
SPECIAL FACILITIES
All service which requires special facilities in order to meet
the customer's service requirements shall be provided subject to
special facilities rider
PRORATION OF UTILITY BILLS
(a) Billing for the Facility charge shall be based on 12
billings annually
Formula
Actual days In reading period x customer charge
30
(b) monthn bs as andnd shall be prorated for longer calculatedon
o shorte0day per
r billing
periods
Formula
Actual days in reading period x KW Demand x Rate
30
PAGE 32
ENERGY COST ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule E C A
PAGE 33
SCHEDULE AF
ATHLETE FIELD
APPLICATION
Applicable to all electric service metered at one point for
use to light specified areas for athletic events where such
electrical use will not occur between the hours of 10 00 A M and
7 00 P M
NET MONTHLY RATE
(1) Customer Facilities Charge
Single Phase
Three Phase
(2) Energy Charge
$20 00 per 30 days
$30 00 per 30 days
Billing months of June through September
All Other Hours(Off Peak) 3 750 per KWH
10 00 AM to 7 00 PM(Peak) 7 50¢ per KWH
(Weekdays excluding City Holidays)
Billing months of October through May
All hours 3 75¢/KWH
(3) Demand Charge
Billing months of June through September
All Other Hours(Off Peak) $1 00 per KW per
30 days
10 00 AM to 7 00 PM(Peak) $4 50 per KW per
30 days
Billing months of October through May
All hours
(4) Energy Cost Adjustment
MINIMUM BILLING
$1 00 per KW per
30 days
Current ECA Schedule
Facility Charge
PAGE 34
TYPE OF SERVICE
At the City's available secondary voltage and available phase
For use only between the hours of 7 00 P M and 10 00 A M from
June through September and all hours from October through May
POWER FACTOR
The City reserves the right to make tests to determine the
power factor of the customer's installation served during periods
of maximum demand or by measurement of the average power factor
for the monthly billing period If the power factor is below
ninety percent, the demand for billing purposes will be determined
by multiplying the uncorrected KW billing demand by 90% and
dividing by the determined power factor
SPECIAL FACILITIES
All services which require special facilities in order to meet
customer's service requirements shall be provided subject to the
special facilities rider
PRORATION OF UTILITY BILLS
(a) Billing for the Facility charge shall be based on 12
billings annually
Formula
Actual days in reading period x customer charge
30
er
(b) Billimonth basis demand
as andprorated for c longer eoro n a 0 shorter bili billing
periods
Formula
Actual days in readin period x KW demand x Rate
3 ays
ENERGY COST ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule E C A
PAGE 35
SCHEDULE ECA
ENERGY COST ADJUSTMENT
ENERGY COST ADJUSTMENT
All monthly KWH charges shall be increased or decreased by an
amount equal to "X" cents per KWH, to be known as the energy cost
adjustment (ECA) The ECA shall be computed in the months of
April and October to be applied to the following periods of May
through October and November through April respectively The
City shall in no case change the energy cost adjustment more than
twice in either of the six (6) months periods The ECA shall be
calculated by the following formula
ECA (Winter) Pro ected energY cost for winter months
Projecte KWH sa es or winter mont s
ECA (Summer) = Pro ected energycost for summer months
rojecte sa es or summer mont s
The above formula results in Winter 1986/87 and Summer 1987
ECA's as follows
ECA (Winter) 2 00¢/KWH
ECA (Summer) = 2 004/KWH
In the event that actual cumulative costs of fuel, variable
costs of Texas Municipal Power Agency (TMPA) energy and purchased
energy (excluding TMPA's fixed charges) is greater than or less
than the cumulative ECA revenues by $1,000,000 during the fiscal
year, the City may recompute the Energy Cost Adjustment and
re-establish an ECA that collects or returns such difference over
the remaining months of the fiscal year Such change in ECA
shall be applied evenly to all remaining months' ECA
PAGE 36
SCHEDULE UPS
UNINTERRUPTIBLE POWER SUPPLY
APPLICATION
Applicable to any customer who, by written agreement,
receives service for uninterruptible power supply for a computer
or other electrical equipment
Not applicable for resale service in any event, nor to
temporary or standby service except in conjunction with
applicable rider
NET MONTHLY RATE
(1) Customer Facility Charge
90 W Power Standby Unit $12 70/30 days
200 W Power Standby Unit $17 50/30 days
(2) Installation Charge $20 00
TYPE OF SERVICE
The City shall furnish, install, maintain an automatically
conolledthetrClty's to
astandardslternating and rrsubject powerent backup
bIts published nfrulesg and
regulations
PAYMENT
Bills are due when rendered, and become past due if not paid
within 15 calendar days from date of issuance
SPECIAL FACILITIES
All services which require special facilities in order to
meet customer's service requirements shall be provided subject to
the special facilities rider
PRORATION OF UTILITY BILLS
(a) Billing for the Facility charge shall be based on 12
billings annually
Formula
Actual days in reading period x customer charge
30
PAGE 37
SECTION II
That if any section, subsection, paragraph, sentence, clause,
phrase or word in this ordinance, or application thereof to any
person or circumstances is held invalid by any court of competent
3urisdiction, such holding shall not affect the validity of the
remaining portions of this ordinance, and the City Council of the
City of Denton, Texas, hereby declares it would have enacted such
remaining portions despite any such invalidity
SECTION III
That the Schedule of Rates adopted by Ordinance No 85-24
shall continue to be effective, charged and applied to the last
regular billing cycle which begins prior to March 3, 1987
SECTION IV
That the Schedule of Rates herein adopted shall be effective,
charged and applied to the first regular billing cycle on or
after March 3, 1987
PASSED AND APPROVED this3� day of , 1987
RL, - - k-: � 2 AY E , MA !OR
CITY DENTON, TEXAS
ATTEST
JE +RA ERSAC TGSECRETARY
CIT OF DENTON, TEXAS
APPROVED AS TO LEGAL FORM
DEBRA ADAMI DRAYOVITCH, CITY ATTORNEY
CITY OF DENTON, TEXAS
BY
PAGE 38
29
AN ORDINANCE OF THE CITY OF DENTON AMENDING SCHEDULES TR, TP, AND
TG OF THE SCHEDULE OF RATES FOR ELECTRICAL SERVICE, AS ADOPTED BY
ORDINANCE NO 87-027, TO PROVIDE FOR A CHANGE IN PEAK PERIODS FOR
ENERGY CHARGES, AND PROVIDING FOR AN EFFECTIVE DATE
THE COUNCIL OF THE CITY OF DENTON HEREBY ORDAINS
SECTION I That Schedule TR (Residential Time of Use
Rates), Schedule TP (Primary Time of Use Rates), and Schedule TG
(General Service Time of Use Rates), of the Schedule of Rates
for electrical service adopted by Ordinance 87-027 on February
3, 1987, are hereby amended to provide for a change in the peak
periods for energy charges from 12 00 noon through 8 00 p m to
1 30 p m through 8 00 p m , in accordance with the revised
Schedules attached hereto and incorporated herein by reference
SECTION II That a copy of this ordinance shall be attached
to Ordinance No 87-027, showing the amendment herein made
PASSED AND APPROVED this the /;V'iw" day of, 1988
RAY SF
F PRENS, 14AYOR
ATTEST
1
NXrEPTWALTERS, CITY SECRETARY
APPROVED AS TO LEGAL FORM
DEBRAiADAMI DRAYOVITCH, CITY ATTORNEY
BY
31
PAYMENT
Bills are due when rendered, and become past due if not paid
within 15 calendar days from date of issuance
SPECIAL FACILITIES
All services which require special facilities in order to
meet customer's service requirements shall be provided subject to
the special facilities rider
PRORATION OF UTILITY BILLS
Billing for the Facility charge shall be based on 12 billings
annually
Formula
Actual days in reading period x customer charge
ENERGY COST ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule E C A
33
SPECIAL FACILITIES
All services which require special facilities in order to
meet the customer's service requirements shall be provided
subject to special facilities rider
PRORATION OF UTILITY BILLS
Billing for the Facility charge shall be based on 12 billings
annually
Formula
Actual days in reading period x customer charge
30
ENERGY COST ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule E.0 A
35
�WM
Bills are due when rendered, and become past due if not paid
within 15 calendar days from date of issuance
SPECIAL FACILITIES
All services which require special facilities in order to
meet customer's service requirements shall be provided subject to
the special facilities rider
PRORATION OF UTILITY BILLS
Billing for the Facility charge shall be based on 12 billings
annually
Formula
Actual days in reading period x customer charge
JU
ENERGY COST ADJUSTMENT
A charge per KWH of energy taken for fuel cost calculated in
accordance with Schedule E C A