Loading...
HomeMy WebLinkAbout1983-099398L NO .5-7m AN ORDINANCE AMENDING CHAPTER 17 OF THE CODE OF ORDINANCES OF THE CITY OF DENTON, TEXAS, BY ADOPTING THE APPENDICES TO THE 1979 EDITION OF THE UNIFORM PLUMBING CODE, PROVIDING FOR CERTAIN DELETIONS AND AMENDMENTS TO THE 1979 EDITION OF THE UNIFORM PLUMBING CODE, INCREASING MINIMUM PLUMBING PERMIT FEES AND DECLARING AN EFFECTIVE DATE THE COUNCIL OF THE CITY OF DENTON, IEXAb, HEREBY ORDAINS PART I That Paragraph (a) of Section 17-2, Chapter 17, Article I of the Code of Ordinances of the City of Denton, Texas, is hereby amended to read as follows (a) The Uniform Plumbing Code, 1979 Edition, and Appendices A through I thereto, as recommended by the International Asso- ciation of Plumbing and Mechanical Officials, a copy of which shall be filed with the Office of the City Secretary as Document No 4 and be available for public inspection, is hereby adopted and designated as the Plumbing Code of the City of Denton, Texas, the same as though said Edition of such code and the appendices thereto were copied at length herein, subject to the deletions and amendments enumerated hereafter (1) (No change from Ordinance No 81-20) (l,l) Amend Section 315 (f) to read No soil or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless adequate provision is made to protect such pipe from freezing All water piping run in an exterior wall, attic, or crawl space shall be adequately insulated to protect from freezing (2) (No change from Ordinance No 81-20) (3) (No change from Ordinance No 81-20) (4) Amend Section 318 2(b) to read (b) Media The piping of the plumbing, drainage and venting systems shall be tested with water or air The administrative authority may require the removal of any clean - out, etc , to ascertain if the pressure has reached all parts of the system After the plumbing fixtures have been set and their traps filled with water, they shall be submitted to a final test All fixtures designed to retain water, such as lava- tories, sinks, bathtubs, laundry trays, etc , shall be filled with water to the overflow level and shall retain same for fiteen (15) minutes without leakage when requested by the Plumbing Inspector (5) Amend Section 401 to read (a) Drainage pipe shall be cast iron, galvanized steel, galvanized wrought iron, lead, copper, brass, ABS or PVC having a smooth and uniform bore, except (1) That no galvanized steel pipe shall be used underground and shall be kept at least six (6) inches (152 4mm) above ground (2) ABS or PVC installations are permitted in buildings not exceeding three (3) stories in height (b) Drainage fittings shall be of cast iron, malleable iron, lead, brass, copper, ABS or PVC having a smooth interior waterway of the same diameter as the piping served and all such fittings shall conform to the type of pipe used (1) Fittings on screwed pipe shall be of the recessed drainage type Burred ends shall be reamed to the full bore of the pipe (2) The threads of drainage fittings shall be tapped so as to allow one fourth (1/4) inch per foot (20 9 mm/m) grade (6) (No change from Ordinance No 81-20) (7) (No change from Ordinance No 81-20) (8) (No change from Ordinance No 81-20) (8 1) Delete Section 904 (b), Connections (9) (No change from Ordinance No 81-20) (9 1) Amend Section 1004 (a) to read (a) Water pipe and fittings shall be of brass, copper, cast iron, galvanized malleable iron, galvanized wrought iron, galvanized steel or lead Schedule 40 PVC having the National Sanitation Foundation seal followed by the letters PW may be used for cold water distribution systems outside of buildings All materials used in the water supply system, except valves and similar devices shall be of a like material, except where otherwise approved by the Administrative authority PAOh 2 (10) (No change from Ordinance No 81-20) (11) (No change from Ordinance No 81-20) (12) (No change from Ordinance No 81-20) (13) (No change from Ordinance No 81-20) (13 1) Amend Section 1212 (a) to read (a) All gas piping used for the installation, exten- sion, alteration, or repair of any gas piping shall be standard weight wrought iron or steel (galvanized or black), yellow brass (containing not more than seventy-five (75%) percent copper), or internally tinned or equivalently treated copper of iron pipe size Approved PE pipe may be used in exterior buried piping systems (14)(a)-(14)(c) (No change from Ordinance No 81-20) (14)(d) Alternate methods of supplying combustion air In lieu of other requirements, combustion air supply may be designed in accordance with recognized engineering principles when first approved by the administrative authority PART II That this ordinance shall become effective immediately upon its passage and approval A PASSED AND APPROVED this the day of 1983 OR C1T OF DE TON, TEXAS ATTEST ���CHAR "fTE LLEN, CI Y SfiCRE CITY OF DENTON, TEXAS APPROVED AS TO LEGAL FORM L J TAYLOR, JR , CITY ATTORNEY CITY OF DENTON, TEXAS BY PAGE 3