HomeMy WebLinkAbout1976-052NO 7to-.5A AN ORDINANCE ADDING TO THE CODE OF ORDINANCES OF THE CITY OF DENTON, TEXAS, A NEW CHAPTER 16 ENTITLED "MECHANICAL CODE" REGULATING THE INSTALLATION, ALTERATION, REPAIRS AND MAINTENANCE OF HEATING, VENTI- LATING, COOLING, AND REFRIGERATION SYSTEMS, INCINERATORS AND MIS- CELLANEOUS HEAT PRODUCING APPLIANCES IN ALL BUILDINGS AND STRUCTURES WITHIN THE CITY, DEFINING ADMINISTRATIVE RESPONSIBILITY, PROVIDING FOR PERMITS AND FEES, PROVIDING ALTERNATIVE REQUIREMENTS, ESTABLISH- ING A MECHANICAL CODE, AND ADOPTING CERTAIN INSTALLATION REQUIREMENTS AND APPENDICES, MAKING THIS ORDINANCE CUMULATIVE OF PRIOR ORDINANCES, REPEALING ALL ORDINANCES AND PROVISIONS OF THE CODE IN CONFLICT HERE- WITH, PROVIDING A SEVERABILITY CLAUSE, PROVIDING A PFNALTY, AND PRO- VIDING AN EFFECTIVE DATE THE COUNCIL OF THE CITY OF DENTON, TEXAS, HEREBY ORDAINS PART I That the Code of Ordinances of the City of Denton, Texas, is hereby amended by adding a new Chapter 16 "Mechanical Code", and it shall hereafter read as follows "ARTICLE I IN GENERAL SECTION 16-1 COMPLIANCE WITH UNIFORM MECHANICAL CODE, 1973 EDITION, REQUIRED The Uniform Mechanical Code, 1973 Edition, copies of which are on file in the office of the City Secretary, is hereby adopted and designated as the Mechanical Code of the City of Denton, the same as though said volume of such code were copied at length herein, subject to the deletions and amendments enumerated hereafter SECTION 16-2 AMENDMENTS TO THE UNIFORM MECHANICAL CODE 1973 EDITION The Uniform Mechanical Code, 1973 Edition, is hereby amended as follows (1) SECTION 202 - Amend Paragraph (2) Change amount of fine from $500 00 to $200 00 and delete "or by imprisonment for no more than six months, or by both such fine and imprisonment " (2) SECTION 203 - Delete as written and amend to read The Plumbinc and Mechanical Code Board as created by Ordinance No 75-51 is hereby adopted as the Board of Appeals for the Mechanical Code (3) SECTION 306 - Add to Paragraph (1) The inspection shall be made within twenty-four (24) hours after such notification, Saturday, Sunday, and holidays excepted (4) SECTION 503 - Add to Paragraph (2) The valve shall be an iron or brass core cock (5) SECTION 505 - Delete sentence (1) and (2) and add Every attic or furred space in which a warm air furnace is installed shall be readily accessible by an opening and passageway as large as the largest piece of the furnace and in no case less than 30" X 22" con- tinuous from the opening to the furnace and its controls (6) SECTION 705 - Add Paragraph (4) Top plates on partitions shall not be cut unless a 16 gauge X 3" steel header strap having two nail holes in each end is used to tie the cut plates together (7) SECTION 710(e) - Delete as written and amend to read Every appliance on a roof of a building shall be installed on a sub- stantial level support No appliance shall be installed on a roof that has a slope greater than 5" vertically to 12" horizontally un- less an appropriate working platform is installed in compliance with State Safety Codes (8) SECTION 1004(a) - Add to Paragraph (1) Piping, wire, conduit, vent pipes or structural members shall not be within the air stream of a supply air duct Where vent pipes serving the plumbing system, vents serving heat producing appliances, natural gas piping or other piping conveying hazardous materials or ob]ect- ionable fumes would occur in the return air system they shall be enclosed in a suitable sleeve at least one inch larger than the pipe enclosed in the sleeve (9) SECTION 1004(b) - Add to Paragraph (2) Joints between non-metallic duct sections other than manufacturer for use without a reinforcing sleeve, shall be reinforced with galvanized metal sleeves, extending at least 4" into the ducts -2- (10) SECTION 1005 - Add to Paragraph (1) Insulation facing shall be legibly marked by manufacturer in repeat patterns not over three feet apart or by retained roll labels indicating his product identification, density, thickness, and type vapor barrier (11) TABLE 10E PART II - Amended Delete No 18 gauge steel wire and add No 14 gauge steel wire (12) SECTION 1511 - Add to last paragraph or use special fittings manufactured for the purpose (13) SECTION 1513 - Delete sentence (1) and amend to read A stop valve shall be installed at the following locations in refrigerant piping of every built-up refrigeration system of 5 h p or larger with accessible type compressors, excluding factory pre -packaged equipment PART II That if any section, subsection, paragraph, sentence, clause, phrase or word in this ordinance, or application thereof to any per- son or circumstances is held invalid by any court of competent juris- diction, such holding shall not affect the validity of the remaining portions of this ordinance, and the City Council of the City of Denton, Texas, hereby declares it would have enacted such remaining portions despite any such invalidity PART III Any person who violates any provision of this ordinance shall be deemed guilty of a misdemeanor, and, upon conviction, shall be punished by a fine not to exceed Two Hundred Dollars ($200 00) Each day such a violation shall continue or be permitted, shall be treated as a separate offense PART IV That this ordinance shall become effective fourteen (14) days from the date of its passage, and the City Secretary is hereby directed to cause the caption of this ordinance to be published -3- twice in the Denton Record -Chronicle, the official newspaper of the City of Denton, Texas, within ten (10) days of the date of its passage PASSED AND APPROVED This the 23rd day of November, A D , 1976 ATTEST ,C WOKS HOLTCITY SEC NARY CITY OF DENTON, TEXAS APPROVED AS TO LEGAL FORM PAUL C I HAM, TY ATTORNEY CITY OF DENTON, TEXAS ELINOR HUGHES, MAJOR CITY OF DENTON, TEXAS -4- t* s