S24-0004a
ORDINANCE NO.S24-0004a AN ORDINANCE OF THE CITY OF DENTON, TEXAS REGARDING A REQUEST FOR A SPECIFIC USE PERMIT (SUP) TO ALLOW FOR A HIGH-IMPACT MANUFACTURING USE ON APPROXIMATELY 9.5 ACRES OF LAND, GENERALLY LOCATED ON THE WEST SIDE OF DAKOTA LANE, APPROXIMATELY 800 FEET SOUTH OF SHELBY LANE, IN THE CITY OF DENTON, DENTON COUNTY, TEXAS; ADOPTING AN AMENDMENT TO THE CITY’S OFFICIAL ZONING MAP; PROVIDING FOR A PENALTY IN THE MAXIMUM AMOUNT OF $2,000.00 FOR VIOLATIONS THEREOF; PROVIDING FOR SEVERABILITY; AND ESTABLISHING AN EFFECTIVE DATE. (S24-0004a) WHEREAS, Jesse Copeland with Winstead, representing the applicant, Advanced Microbial Solutions, LLC has applied for a new Specific Use Permit (“SUP”) to allow for a High- Impact Manufacturing use on an approximately 9.5-acre site, within the Heavy Industrial (Hl) zoning district and use classification, as described in Exhibit “A” (hereinafter, “the Property”); and WHEREAS, on June 12, 2024, the Planning and Zoning Commission, in compliance with the laws of the State of Texas, having given the requisite notices by publication and otherwise, and having afforded full and fair hearings and to all property owners interested in this regard, has recommended approval [6 – 0] of the requested SUP, subject to conditions; and WHEREAS, on July 16, 2024, the City Council likewise conducted a public hearing as required by law to consider the SUP request. Upon consideration, the City Council hereby finds that the request is consistent with the Denton Plan and federal, state, and local law, and that the Applicant has agreed to comply with all provisions of the Denton Development Code (“DDC”), and has further agreed to comply with the additional restrictions and conditions set forth herein; and WHEREAS, the City Council has determined that it will be beneficial to Denton and its citizens to grant the SUP; that such grant will not be detrimental to the public welfare, safety, or health; that proposed permit, as conditioned below, satisfies criteria set forth in Sections 2.4.5E and 2.5.2D of the Denton Development Code; and that the SUP should be granted; NOW THEREFORE, THE COUNCIL OF THE CITY OF DENTON HEREBY ORDAINS: SECTION 1. The findings and recitations contained in the preamble of this ordinance are incorporated herein by reference and found to be true. SECTION 2. The SUP to allow the High-Impact Manufacturing use on the Property as shown on the site plan and site layout plan attached and incorporated herein as Exhibit “B” and Exhibit “C,” is hereby approved, with the following conditions: 1. The zoning map shall reflect the Specific Use Permit on the property consistent with the DDC I 2. Maintain compliance with the Texas Muitisector Storm Water General Permit and update the certification every 5 years or as required by Texas Commission on Environmental Quality. Documentation shall be provided to the City upon request demonstrating compliance. 3. The chiller shall be relocated outside of the floodway and the 100-year floodplain within 90 days of the SUP effective date. Additionally, all mechanical equipment shall be located outside of the floodway and the 100-year floodplain. 4. Outdoor storage is not permitted within the floodway and 100-year floodplain. Therefore, all outdoor storage, including tractor trailers, shall be removed within 90 days of the SUP effective date and not stored in the floodway and floodplain. 5. All stored hazardous chemicals shall be located inside the buildings only. Outdoor storage tanks shown on the plans are not permitted to hold hazardous materials. 6. Any hazardous chemicals stored onsite shall require approval from the Fire Department within 90 days of the SUP effective date, including obtaining any necessary permits. 7. Obtain all necessary permits within 90 days of the SUP effective date to achieve proper storage and placement of materials or chemicals within control area(s) in accordance with the 202 1 International Building Code. 8. Maintain a spill response team that entails staff training at least once a year to review Standard Operating Procedures. Documentation shall be provided to the City upon request demonstrating compliance . 9. Prior to any manufacturing or processing wastewater discharge being connected to the City’s wastewater collection system, building permit plans shall be submitted to the City for review and approval and issuance of applicable wastewater discharge permit. SECTION 3. Failure to Comply. Except as otherwise stated above, all terms of the SUP shall be complied with prior to issuance of a Certificate of Occupancy. Failure to comply with any term or condition of the Ordinance will result in the SUP being declared null and void, and of no force and effect. The SUP is issued to the entity named above runs with the land and is assignable and transferable to subsequent owners of the Property. SECTION 4. SUP Regulations. Upon notice to the property owner and a hearing before the City Council, a SUP may be revoked or modified if: 1. There is one or more of the conditions imposed by this Ordinance that has not been met or has been violated on the Property; or 2. The SUP was obtained or extended by fraud or deception; or 3. As otherwise permitted by law and/or permitted by the Denton Development Code. SECTION 5. Unlawful use. It shall be unlawful for any person, firm, entity, or corporatio to mak© use of the above-referenced Property in some manner other than as authorized by the Denton’s Codes of Ordinances and this Ordinance. 2 SECTION 6. Severability. If any provision of this ordinance or the application thereof to any person or circumstance is held invalid by any court, such invalidity shall affect the validity of the provisions or applications, and to this end the provisions of this ordinance are severable. SECTION 7. Penalty. Any person, firm, entity or corporation violating any provision of this ordinance shall, upon conviction, be fined a sum not exceeding $2,000.00 for each violation. Each day that a provision of this ordinance is violated shall constitute a separate and distinct offense. The penal provisions imposed under this Ordinance shall not preclude Denton from filing suit to enjoin the violation and it retains all legal rights and remedies available to it under local, state and federal law. SECTION 8. In compliance with Section 2.09(c) of the Denton Charter, this ordinance shall become effective fourteen (14) days from the date of its passage, and the City Secretary is hereby directed to cause the caption of this ordinance to be published twice in the Denton Record- Chronicle, a daily newspaper published in the City of Denton, Texas, within ten (10) days of the date of its passage. :;'"'YhT’T::FJh:;'~:""''"”":f„:“„f„',',::=,Ph:hY,Sc,';,==;'::”1: following vote L - Aye Nay Abstain Absent Mayor Gerard Hudspeth:,/ ,/ L/ L/ &/ Vicki Byrd, District 1 : Brian Beck, District 2 :L/ Paul Meltzer, District 3 : Joe Holland, District 4: Brandon Chase IVlcGee, At Large Place 5 : Jill Jester, At Large Place 6: PASSED ANDAPPROVEDMisthe /6 h day of J-Iv _, 2024. miKmb ATTEST: 3 LAUREN THODEN, CITY SECRETARY APPROVED AS TO LEGAL FORM: MACK REINWAND, CITY ATTORNEY -'+'I'-'-BY: U EXHIBIT A Corbin Road Industrial Park. Block A, Lot 2R, 3R, and 4R. ii IM ! liiii ;+++ ];iiiloo'e Le q;:;;!!i !i Rd dG < Z; y Eg E Q g i ! ! ! on 2 >i ;!!!!ii fB C) fr < ! ! ! lz9'ez 3v gr\ =n•Hl• ) II r'I,v-aIUVl–IDIPN 9Nlalirlq aNO nuJS:=:==a :=:n lz6m lILLl90o00 S Fit+Hi a) a) +=1 g / // // / /-A /2f;/9/;/ § inalq i 4951 Capacity (GL) 28,000 28,000 3,000 9,500 28,000 28,000 28,000 28,000 28.000 28, OOO 28,000 28,000 28,000 28,000 28,000 28,000 42, OOO 42,000 42, OOO Dakota Lane - Legend Diameter Height (IN) (IN)Code TOI T02 T03 T04 T05 T06 T07 T08 T09 T1 O T1 1 T12 T1 3 T14 T1 5 T16 T17 T18 T1 9 Tank Material Fiberglass Fiberglass Poly Stainless Steel Fiberglass Fiberglass Fiberglass Fiberglass Fiberglass Fiberglass Fiberglass Fiberglass Fiberglass Fiberglass Fiberglass Fiberglass Fiberglass Fiberglass Fiberglass Type Flat Bottom Fiat Bottom Cone Bottom Cone Bottom Flat Bottom Cone Bottom Flat Bottom Flat Bottom Flat Bottom Flat Bottom Flat Bottom Flat Bottom Flat Bottom Flat Bottom Flat Bottom Flat Bottom Flat Bottom Flat Bottom Flat Bottom Potentially Hazardous No No No No No No No No No No No No No No No No No No No Description 240 Process Tank Contents Water Water Water Accomplish LM Accomplish LM Accomplish LM Accomplish LM Accomplish LM Accomplish LM Accomplish LM Accomplish LM Accomplish LM Accomplish LM Accomplish LM Accomplish LM Accomplish LM Soilbuilder MC Accomplish LM Accomplish LM 186 186 240 Process Tank 96 120 Process Tank 144 186 Process Tank 186 240 Process Tank 186 240 Process Tank 186 240 Process Tank 186 240 Process Tank 186 240 Process Tank 186 240 Process Tank 186 240 Process Tank 186 240 Process Tank 186 240 Process Tank 186 240 Process Tank 186 240 Process Tank 186 240 Process Tank FP Storage 360 Tank FP Storage Tank FP Storage Tank 186 186 360 186 360 Tank Material Fiberglass Fiberglass Fiberglass Fiberglass Fiberglass Fiberglass Fiberglass Fiberglass Fiberglass Fiberglass Fiberglass Fiberglass Fiberglass Fiberglass Fiberglass Fiberglass Fiberglass Poly Poly Poly Capacity (GAL) 42,000 42,000 42,000 42,000 42,000 42,000 42,000 42,000 42,000 42,000 42,000 42,000 42,000 42,000 42,000 42,000 42,000 10,000 10,000 10,000 Diameter (IN) 186 186 186 186 186 186 186 186 186 186 186 186 186 186 186 186 186 142 142 142 Height (IN) 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 208 208 208 Potentiall! Hazardous No No No No No No No No No No No No No No No No No No No No Code T20 T21 T22 T23 T24 T25 T26 T27 T28 T29 T30 T31 T32 T33 T34 T35 T36 T37 T38 T39 Type Flat Bottom Flat Bottom Flat Bottom Flat Bottom Flat Bottom Flat Bottom Flat Bottom Flat Bottom Flat Bottom Flat Bottom Flat Bottorn Flat Bottom Flat Bottom Flat Bottom Flat Bottom Flat Bottom Flat Bottom Cone Bottom Cone Bottom Cone Bottom Description FP Storage Tank FP Storage Tank FP Storage Tank FP Storage Tank FP Storage Tank FP Storage Tank FP Storage Tank FP Storage Tank FP Storage Tank FP Storage Tank FP Storage Tank FP Storage Tank FP Storage Tank FP Storage Tank FP Storage Tank FP Storage Tank FP Storage Tank Process Tank Process Tank Process Tank Contents Maritime CA (AGS I033) Accomplish LM AccomplishLM AccomplishLM AccomplishLM Maritirne CA (AGS 1033) Soilbuilder MC Accomplish LM AccomplishLM Accomplish LM Accomplish LM AccomplishLM Accomplish LM AccomplishLM Accomplish LM AccomplishLM Accomplish LM Accomplish LM Accomplish LM Accomplish LM Code T40 T4 1 T42 T43 T44 T45 T46 T47 T48 T49 T50 T51 T52 T53 T54 T55 T56 T57 Tank Material Poly Poly Poly Poly Poly Poly Poly Poly Stainless Steel Poly Poly Poly Poly Poly Poly Poly Poly Poly Type Cone Bottom Cone Bottom Cone Bottom Cone Bottom Cone Bottom Cone Bottom Cone Bottom Cone Bottom Cone Bottom Cone Bottom Cone Bottom Cone Bottom Cone Bottom Cone Bottom Cone Bottom Cone Bottom Cone Bottom Cone Bottom Capacity (GAL) 10,000 10,000 10,000 10,000 10,000 10,000 10,000 5,500 5,500 8,250 8,250 8.250 5,500 5,500 5,500 5,500 10.000 10,000 Diameter (IN) 142 142 142 142 142 142 142 90 132 122 122 122 120 90 90 90 142 142 Height (IN) 208 208 208 208 208 208 208 241 144 193 193 193 204 241 241 241 208 208 Potentially Hazardous No No No No No No No No No No No No No No SDS Provided No No No Description Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank FP Storage Tank Loadout Tank Ingredient Storage Tank Ingredient Storage Tank Ingredient Storage Tank Ingredient Storage Tank Ingredient Storage Tank Ingredient Storage Tank Ingredient Storage Tank BLEND TANK BLEND TANK Contents Accomplish LM Accomplish LM Accomplish LM Accomplish LM Accomplish LM Accomplish LM Accomplish LM Soilbuilder MC VARIOUS KA-60 MBT-E PST CBT HA-20 UAN-32 KA-60 VARIOUS VARiOUS 5001 Dakota Lane – Legend CAPACITY DIAMrrER HEIGHT (GAL) ( IN) (IN) DESCRIPTION FP Storage42.000 1 86 360 Tank - FP Storage42,000 1 86 360 Tank - FP Storage 360 Tank - FP Storage 360 Tank - FP Storage 360 Tank - FP Storage 360 Tank - FP Storage 360 Tank - FP Storage 360 Tank - FP Storage 300 Tank - FP Storage 300 Tank - FP Storage 300 Tank . FP Storage 300 Tank - FP Storage 300 Tank - FP Storage 241 Tank - FP Storage 241 Tank - FP Storage 241 Tank - FP Storage 241 Tank - FP Storage 241 Tank - FP Storage 241 Tank . TANK MATERIAL Fiberglass Fiberglass Fiberglass Fiberglass Fiberglass FibergLass Fiberglass Fiberglass Fibergtass FibergLass FibergLass Fiberglass Fiberglass Poly Poly Poly PoLy PoLy Poly POTENTIALLY HAZARDOUS? No No No No No No No No No No No No No No No No No No No CODE TOI T02 T03 T04 TOS T06 T07 T08 T09 TIO T1 1 T1 2 T1 3 T1 4 T1 5 T1 6 T1 7 T18 T19 TYPE Ftatbottom Flatbottom FLatbottorn Flat bottom Ftatbottom Flatbottom FLatbottom Ftatbottom Flat bottom Flatbottom Flatbottom Ftatbottom Flatbottom Conebottom Conebottom Conebottom Conebottom Conebottom Conebottom CONTENTS MARITIME CA (AGS 1033) MARITIME CA (AGS 1033) MARITIME CA (AGS 1033) MARITIME CA (AGS 1033) MARITIME CA (AGS 1033) MARITIME CA (ACS 1033) PST (AGS 1 038) PST (AGS 1 038) PST (AGS 1038) PST (ACS 1038) M BT-E (ACS 1 1 99) MARITIME CA (AGS 1033) MARITIME CA (AGS 1033) CBT (AGS 1 1 50) CBT (AGS 1 1 50) CBT (AGS 1 150) CBT (AGS 1 1 50) CBT (ACS 1 150) CBT (AGS 1 1 50) 42,000 42,000 42,000 42,000 42,000 42,000 22,000 22,000 22,000 22,000 22,000 5,500 5,500 5,500 5,500 5,500 5,500 186 186 186 186 186 186 144 144 144 144 144 DU 90 90 90 90 90 TANK MATERIAL Poly PoLy Poly Poly Poly Poly Poly PoLy PoLy Poly Poly Poly Poly Poly Poly PoLy Poly Poly Poly PoLy CAPACITY (GAL) 5,500 8,250 8,250 8,250 8,250 8,250 8,250 8,250 8,250 8,250 8,250 8,250 4,200 8,000 4,200 4,200 4,200 4,200 4,200 4,200 POTENTIALLY HAZARDOUS? No No No No No No No No No No No No No No No No No No No No CODE T20 T21 T22 T23 T24 T25 T26 T27 T28 T29 T30 T31 T32 T33 T34 T35 T36 T37 T38 T39 DIAMFrER (IN) 90 122 122 122 122 122 122 122 122 122 122 122 122 122 122 122 122 122 122 122 HEIGHT (IN) 241 193 193 193 193 193 193 193 193 193 193 193 113 180 113 113 113 113 113 113 TYPE Conebottom Conebottom Conebottom Conebottom Conebottom Conebotto m Conebottom Conebottom Conebottom Conebottom Conebottam (;onebottom Conebottom Conebottom Conebottom Conebottom Conebottom Conebottom Conebottom Conebottom DESCRIPTION FP Storage Tank - FP Storage Tank - FP Storage Tank - FP Storage Tank - FP Storage Tank - FP Storage Tank - FP Storage Tank - FP Storage Tank - FP Storage Tank - FP Storage Tank - FP Storage Tank - FP Storage Tank - Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank CONTENTS CBT (AGS 1 1 50) CBT tAGS 1150) CBT (AGS 1 1 50) CBT (AGS 1 150) CBT (AGS 1 150) CBT (AGS 1 1 50) CBT (AGS 1 150) CBT (AGS 1 1 50) CBT (AGS 1150) CBT (ACS 1150) CBT (AGS 1150) CBT (AGS 1 150) WATER CBT (AGS 1 150) CBT (AGS 1 1 50) CBT (ACS 1 1 50) CBT (ACS 1 1 50) CBT (AGS 1 1 50) CBT tAGS 1 150) CBT tAGS 1 1 50) CODE T40 T41 T42 T43 T44 T45 T46 T47 T48 T49 T50 T51 T52 T53 T54 T55 T56 T57 T58 T59 TANK MATERIAL PoLy Poly Poly Poly Poly Poly PoLy Poly Poly Poly Poly Poly Poly Poly Poly Poly Poly PoLy PoLy Poly CAPACITY (GAL) 4,200 4,200 1 ,000 8,250 8,250 5,500 1 ,000 9,500 9,500 1 ,000 1 ,000 5,500 5,500 5,500 5,500 5,500 5,500 5,500 5,500 5,500 POTENTIALLY HAZARDOUS? No No No No No No No No No No No No No No No No No No No No TYPE Conebottom Conebottom Conebottom Conebottorn Conebottom Conebottom Conebottom Flatbottom Flatbottom Conebottom Conebottom Conebottom Conebottom Conebottom Conebottom Conebottom Conebottom Conebottom Conebottom Conebottom DIAMETER (IN) 122 122 64 122 122 90 64 120 120 64 64 90 90 90 90 90 90 90 90 90 HEIGHT (IN) 113 113 99 193 193 241 99 204 204 98 98 241 241 241 241 241 241 241 241 241 DESCRIPTION Process Tank Process Tank Process Tank FP Storage Tank - FP Storage Tank - Ingredient Storage Tank Ingredient Storage Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank CONTENTS CBT tAGS 1 1 50) CBT (AGS 1 1 50) CBT (AGS 1 150) Terra Mar 0-0-2 TerraMar 0-0-2 KA-60 PRO-K WATER WATER MARITIME CA (AGS 1033) MARITIME CA (ACS 1033) MARITIME CA (ACS 1033) MARITIME CA (AGS 1033) MARITIME CA (AGS 1033) MARITIME CA (AGS 1033) MARITIME CA (ACS 1033) MARiTIME CA (ACS 1033) MARITIME CA (AGS 1033) MARITIME CA tAGS 1033) MARITIME CA (AGS 1033) CODE T60 T61 T62 T63 T64 T65 T66 T67 T68 T69 T70 T71 T72 T73 T74 T75 T76 T77 T78 T79 TANK MATERIAL Poly Poly Poly Poly Poly Poly Poly Poly Poty STEEL Poly Poly Poly Poly Poly Poly Poly Poly Poly Poly TYPE Conebottom Conebottom Conebottom Flatbottom Flatbottom Flatbottom Ftatbottom Flatbottom Flatbottom CUSTOM Conebottom Ftatbottom Ftatbottom Ftatbottom Ftatbottom Flatbottom Conebottom Conebottom Conebottom Conebottom CAPACITY (GAL) 5,500 5,500 5,500 6,500 6,500 6,500 6,500 6,500 6,500 33,000 500 1 ,650 1 ,650 12,500 12,500 5,600 200 1 ,010 1,010 1,010 DIAMFrER (IN) 90 90 90 102 102 102 102 102 102 NA 64 68 68 142 1 42 120 38 64 64 64 HEIGHT (IN) 241 241 241 196 196 196 196 196 196 192 72 78 78 21 6 216 120 66 99 99 99 POTENTIALLY HAZARDOUS? No No No No No No No No No No No No No No No No No No No No DESCRIPTION Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank CONTENTS MARITIME CA (AGS 1033) MARITIME CA (AGS 1033) MARITIME CA (AGS 1033) MARITIME CA (AGS 1033) MARITIME CA (AGS 1 033) MARITIME CA (AGS 1033) MARITIME CA (AGS 1033) MARITIME CA (AGS 1033) MARITIME CA (ACS 1033) PST (AGS 1 038) PST (AGS 1038) PST (ACS 1 038) PST (AGS 1 038) WATER PST (AGS 1 038) PST (AGS 1 038) MB FE (AGS 1 1 99) MBT-E (AGS 1199) MBT-E (AGS 1 199) MBT-E (AGS 1 199) TANK MATERIAL Poly Poly Poly Poly Poly Poly Poly Poly Poly Poly Poly Poly Poly Poly Poly Poly Poly Poly Poly Poly POTENTIALLY HAZARDOUS? No No No No No No No No No No No No No No No No No No No No CODE T80 T81 T82 T83 T84 T85 T86 T87 T88 T89 T9a T91 T92 T93 T94 T95 T96 T97 T98 T99 CAPACITY (GAL) 1 ,010 1,010 1 ,01 0 275 200 1 ,010 1,010 1,010 1,010 1,010 1 ,010 275 200 1,010 1 ,010 1,010 1 ,010 1 ,010 1 ,010 275 DIAMETER (IN) 64 64 64 NA 38 64 64 64 64 64 64 NA 38 64 64 64 64 64 64 NA HEIGHT (IN) 99 99 99 48 66 99 99 99 99 99 99 48 66 99 99 99 99 99 99 48 TYPE Conebottom Conebottom Conebottom Flatbottom Conebottom Conebottom Conebottom Conebottom Conebottom Conebottom Conebottom FLatbottom Conebottom Conebottom Conebottom Conebottom Conebottom Conebottom Conebottom Flatbottom DESCRIPTION Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank Process Tank CONTENTS MBT-E (AGS 1 1 99) M BT-E (AGS 1 199) MBT-E (AGS 1 199) M BT-E (AGS 1 199) M BT-E (AGS 1 199) MBT-E (AGS 1 199) MBT-E (AGS 1 199) MBT-E (AGS 1 199) MBT-E (ACS 1 1 99) MBT-E (AGS 1 1 99) MBT-E ( AGS 1 1 99) MBT-E (AGS 1 1 99) N-Trifecta (ACS 1306) N-Trifecta (ACS 1306) N-Trifecta {AGS 1306) N-Trifecta (AGS 1306) N-Trifecta (AGS 1306) N-Trifecta (AGS 1306) N-Trifecta (ACS 1306) N-Trifecta (AGS 1306) TANK CODE MATERIAL TYPE CAPACITY DIAMEtER HEIGHT €GAL) (IN) (IN) D£SCRIPTION CONTENTS Conebottom liOOO M 98 ProcessTank WATER Conebottom 2,440 Flatbottom 6,500 Ftatbottom 6,500 Ftatbottom 6,500 Ftatbottom 6,500 Conebottom 200 POTENTIALLY HAZARDOUS? No No No No No No No T1 00 Poly T1 01 Poly T1 02 Poly T1 Q3 Poly T1 Q4 Poly T1 Q5 Poly T1 06 Poly 91 117 ProcessTank WATER 102 196 ProcessTank MBT-E (AGS 1199) FP Storage 196 Tank - N-Trifecta (AGS 1306) FP Storage 196 Tank - MBT-E (AGS 1 1 99) FP Storage 196 Tank - N-Trifecta (ACS 1306) 55 ProcessTank PST(AGS 1038) 102 102 102 42 LU(9 <(a(0I C/) LU1-01- 1-Z LUa LU0( CDZ i\/ g ONK)