Loading...
HomeMy WebLinkAbout2003-198ORDINANCE NO. AN ORDINANCE GRANTING APPROVAL OF A LICENSE AGREEMENT FOR THE SUBSURFACE USE OF A PORTION OF THE DENTON BRANCH RAIL TRAIL 600 FEET NORTH OF POCKRUS PAGE ROAD AT MILE POST 725.7 FOR THE PURPOSE OF AN UNDERGROUND ELECTRIC LINE CROSSING IN ACCORDANCE WITH CHAPTER 26 OF THE TEXAS PARKS AND WILDLIFE CODE; PROVIDING FOR THE ISSUANCE OF A LICENSE; AND PROVIDING AN EFFECTIVE DATE. WHEREAS, Section 26.001 of the Texas Parks of Wildlife Code provides that public land designated and used as a park may be used for a non -park purpose if the City Council finds after notice and hearing that there is not feasible and prudent alternative to the use of such land for the proposed project and the proposed project includes all reasonable planning to minimize the harm to the park resulting from such use; and WHEREAS, the City of Denton desires to cooperate with the Denton Municipal Electric in the development of properties within the City of Denton by providing a license for the construction of an underground electric line 100 linear feet across the trail for an electric distribution line; and WHEREAS, Denton Municipal Electric desires to construct the subsurface electric line across the Denton Branch Rail/Trail since alternative options would not be feasible and prudent; and WHEREAS, the City provided notice in the Denton Record Chronicle on May 26, June 2, and June 16, 2003 of a Public Hearing to be held on June 17, 2003 in the Council Chambers to consider the alternatives to the use of City Park and Recreational land for the subject subsurface electric line project; and WHEREAS, the City Council on June 17, 2003, received testimony from City staff and citizens regarding alternatives to the use of the Denton Branch Rail/Trail for this subsurface electric line; and WHEREAS, the City Council finds that the fact situation discussed above does not fall within the purview of Section 253.001 of the Texas Local Government Code; and WHEREAS, the City Council finds that there is no feasible and prudent alternative to the use of the Park land and that the subsurface electric line project when constructed in accordance with the provisions of the license as described below will minimize the harm to the park land resulting from the proposed use and the surface of such park land effected shall remain useable for the park patrons once the construction of the electric line improvements are completed; NOW, THEREFORE, THE COUNCIL OF THE CITY OF DENTON HEREBY ORDAINS: SECTION 1. The subsurface electric line proposed by Denton Municipal Electric must be constructed and maintained below the surface of the park property described in Exhibit A, SA0ur Documents\OrdinnncM\03\Chapter 26 DME electric line, MP 725.7 Pockrm Page rd.doc which is attached hereto and made a part hereof for all purposes, and that the surface of the park after installation of the overhead electric line be constructed in a manner so that the park land may still be used by its patrons after completion of the project in the same manner it was used prior to the project. SECTION 2. A License which is revocable as required by law (National Trails System Act, 16 U.S.C. 1247(d)) be composed by the City Manager or his designee and approved by the City Attorney allowing the use of the park property as referenced above with appropriate provision to insure the improvements are constructed in accordance with City Subdivision Rules and Regulations; American Railway Engineering and Maintenance of Way standards, protects the patrons using the park from injury and damage both during and after construction of the project; compensates the City for the reasonable market value of the use herein granted and generally protect the health, safety and general welfare of the City. SECTION 3. During construction of the above described improvements, Denton Municipal Electric may have temporary use of such additional park land necessary to stage the construction of the improvements as may be approved by the Director of Parks and Recreation Department and at the completion of the construction activities for the above improvements such additional park land shall be restored to the condition to which it existed prior to the beginning of such construction activities. SECTION 4. The rights and benefits set forth in this ordinance may not be assigned without the express written consent of the City. SECTION 5. The License above grantee shall, to the extent allowed by law, constitute a covenant running with the land and be filed in the Deed Records of Denton County, Texas. SECTION 6. The findings contained in the preamble of this ordinance are incorporated into the body of this ordinance. SECTION 7. This ordinance shall become effective immediately upon its passage and approval. PASSED AND APPROVED this the Iff day of j� 2003. EULINE BROCK, MAYOR ATTEST: WALTERS, CI17Y SECRETARY APIWOVEDWS TO LEGAL FORM: HERBERT L. UTY, C ATTORNEY By: SAOur Documenw\Ordinnnces\OMapter 26 DM electric line, MP 725.7 POGvus Page ad.Page 2 of 2 Exhibit A Application to The City of Denton Park Department For License to Install Wire Lines Encroaching Under, Over, or Parallel Tracks of the Rails to Trails 1. Applicant Information Data SIR/ns Name of Applicant: Address of Applicant: Check One: () Individual () Co -partnership () Corporation () Municipality Contact Person (Preferably, Engineer): Donald noel anghlin gan_z u 711a phone # check one: (X) Underground () Overhead () Parallel If overhead; vertical clearance is ' a 28' minimum is required from top of rail to bottom of overhead crossing point. If parallel will there be poles on Railway right-of-way_, if yes please show location on prints. Location of wireline Crossing in relation to centerline of Railroad Tracks at Mile Post _ plus _ feet if parallel give beginning Mile Post_ plus _feet to Mile Post_ plus _feet. If Spur give distance from point of Switch feet. 4. Near Denton rname of City, Town, or Village and State) in Denton Parish/County, Section Township Range Distance from inside face of backwall on nearest Railroad Bridge (Give Bridge # if available) Distance from Centerline of DOT-AAR Numbered Vehicular Crossing (Give DOT #) ono' Nnrth of intersaetion of Pnekma and Rails to Traila 6. Will wireline be in a dedicated street or Highway? NO r If yes, please provide documented information proving ownership of street or highway RAN. 7. Angle wire line crossing the Railway Tracks: a0_-_'-_" & Type of Wire: ( )Telephone ( X ) Power Line (if powerline please provide voltage {) Fiber Optic ( ) other (please specify) ynnagot InAnn onitc 9. Size: ta" Material: Steel 10. Depth of top of casing pipe below base of rail as' (minimum 5 1/2 feet) (minimum 36 inch depth between top of casing and natural ground or ditch bottom on Railway right-of-way.) 11. Length of casing pipe: Inn' (If casing is vented, casing shall extend to right-of-way lines, if not vented casing shall be a minimum 25' each side as measured at right angles to centerline of track.) 12 Will casing pipe have protective coating? Nn Type: 13. Will casing pipe be cathodically protected?—Na 14. Method of installing casing Pipe: n A bow (Dry bore and jack or directional bore; wet boring will not be permitted.) 15. Will casing pipe be vented? Nn Diameter. (minimum 2 inches) All wire lines will be marked at entry and exit to railway right-of-way with a sign mounted on a substantial post at least 4 feet above ground surface. The sign must convey the type of wire line, name of licensee, address of licensee, emergency phone number and any emergency response Information. Height above ground surface: (minimum 4 feet) Applicant to furnish 2 copies of the fully completed questionnaire and 2-8 1/2' x 11" or 14" prints showing drawing with crossing measured from the nearest mile post, Bridge backwall, point of main line switch and DOT-AAR numbered vehicular crossing, as well as limits of railroad (and street or highway if involved) right-of-way; plus 2 prints of profile sketch of actual situation showing relationship of tracks, contours of ground and surface ditches, the wire line, other buried pipe lines or wire lines (if known), etc. This is to be used to prepare exhibit for agreement. (PRINTS NFFn Tn SHQW NORTH G Signature of Applicant \ s 3CALE: 1 = 200' DESCRIPTION DENTON MUNICIPAL ELECTRIC REQUESTS A PERMITTO BORE ACROSS R.O.W. AND INSTALL 3 -6' CONDUITS IN 18" STEEL ENCASEMENT W/ 750 MCM 30 CABLE, LOCATED 600' NORTH OF CENTERLINE OF POCKRUS RD. POCKRUS = El TOP VIEW I I PROPOSED BORE 18 O CROSSING W/3-6' � CONDUITS IN 18" STEEL �, S ENCASEMENT W/ 1 RUN 750 MCM 30 CABLE I I° ISCALE: 1 HOR. 1" = 25' �\ Iz CENTERLNEO PROP051_ _IEO \ ELECTRIC BORE CROSSNO \(3-YCMDUMIN18'S EL ENCRSEMENTWI RUN70 RO MCM00GSLE) \ 9 \ V \ CENTERLNEO AO \POCKRUS RD. m 30" WATERLINE b �I 2T' WATERLINE I_ PROFILE RD. s10 ��_ j I I I I I I I—I+I 600NORTH ' OF CENTERLINE POCKRUS I 3 _ I 605 I I _V- I ._ GROUND -LINE - ITER -GROUNDLINE �. ILSi—� 30�RAW LINE —I — _ 600 65-MINIMUM 595 �I � —� I 590 I I I SCA f- - - - I IPR�LP_OSEOBORE W/3 18 BTEE T=WATER' I— — 1FHOR i25' 1 IN NCACSROSSIN�G ICONDUITS EMENTW/ 1 RU SUPPLY LINEL—! I I750 MOM CABLE— 16"— -7 I_1 I —I _ CAMON NI C I P A L L L C C T H I Q [UW* `N.wgWs, Permit Reg. - Pockrus New CircuiDAM t; 60041$00 F o krus Sub - Denton, TX 76209 arxE: (varies) EmlOdw ,p D&m* Bw w. Edsel Sapian � Fare Emadi mm 5/15/0 ,.m WN . 1 of 1