2019.01.03_COD_FollowUp i Gas Well Inspection Type 2018 Annual � L��OF I n s p e ct i o n s Inspection Cycle 2nd Half _ DENTOR 24hr Phone 855-820-6008 Well Operator Eagleridge Inspection Date 11-16-18 Record Active Close Date 12-20-18 Padsite Name 59 Cod Airport B Pad Jurisdiction COD Re-Inspection Date 12-20-18 Site Address 7483 Tom Cole Rd Padsite Type Multi Well Rt 14 2nd Follow-up Inspection Ordinance Reg 2005-223 Rod Weatherby Inspected by y Inspection Status Closed Plat/Site Permit No Plan No Lease Name .RRC Id Aai No. Spud Date Imoact 1106-0515 GWP05-0014 CITY OF DENTON-AIRPORT 4H 252629 12132677 1/2/2009 Low 1106-0516 GWP05-0014 CITY OF DENTON-AIRPORT 7H 252636 12133130 1/20/2009 Low INSPECTION CHECK LIST Signs/Labels General Location Operator Name • Good Need Resolved Fencing • Good Need Resolved Site Address • Good Need Resolved Entry Gate Locked • Good Need Resolved Well Name • Good Need Resolved Site Surface • Good Need Resolved 24hr.Phone No • Good Need Resolved Stains • Good Need Resolved RRC&Api No • Good Need Resolved Trash/Debris • Good Need Resolved No Smoking • Good Need Resolved Weeds/Brush Good Need • Resolved Reflective/Lighting • Good Need Resolved Oders/Fumes/Dust • Good Need Resolved Wellhead Sign • Good Need Resolved Site Lighting • Good Need Resolved Tank Battery Sign • Good Need Resolved Landscaping • Good Need Resolved Storage Tank Labels • Good Need Resolved Erosion Control • Good Need Resolved Facility Equipment Miscellaneous Wellhead Paint • Good Need Resolved Electric Lines Safe • Good Need Resolved Wellhead Leaks Good Need • Resolved Pipeline Markers • Good Need Resolved Tank Battery Paint • Good Need Resolved Layout per Site Plan • Good Need Resolved Tank Battery Leaks Good Need • Resolved Tank Integrity • Good Need Resolved No Wells Approved Db Level @ Inspection Containment Integrity • Good Need Resolved Fire Dept. Drip Pots@ Load • Good Need Resolved Lightning Arresting • Good Need Resolved Fire Lane Access Referred Tank Level Activated Referred Equip Height • Good Need Resolved Foam Lines Referred Pit Fencing Referred Accessible ESD Referred Auto Safety Valve Referred Inspection Comments Weed control needed. #7 WH Tubing head venting, needing immediate action. Operator made call for crew. Crew arrived and made repairs within 2 hours of discovery. DV Controllers venting needs repair. Operator made repairs during inspection. On 12/20/18,RW —conducted a follow-up inspection of the well site.Operator resolved all items requiring further attention.