Loading...
2019.01.07_COD_FollowUp i Gas Well Inspection Type 2018 Annual � L��OF I n s p e ct i o n s Inspection Cycle 2nd Half _ DENTOR 24hr Phone 855-820-6008 Well Operator Eagleridge Inspection Date 11-19-18 Record Close Date 1-4-19 Active Padsite Name 15 Smith-Braewood Pad Jurisdiction CoD Re-Inspection Date 1-4-19 Site Address 2801 Bonnie Brae Padsite Type Multi Well Rt 27 2nd Follow-up Inspection Ordinance Reg 2002-040 Rod Weatherby Inspected by y Inspection Status Closed Plat/Site Permit No Plan No Lease Name _ _RRC Id Aoi No. Spud Date Imoact 1106-0489 GWP02-0007 BRAEWOOD 1 H 237614 12133083 10/28/2007 Moderate 1106-0498 GWP02-0007 SMITH UNIT 1 195446 12131748 12/18/2002 Moderate 1106-0499 GWP02-0007 SMITH-BRAEWOOD 2 196437 12131917 5/1/2003 Moderate INSPECTION CHECK LIST Signs/Labels General Location I Operator Name • Good Need Resolved Fencing • Good Need Resolved Site Address • Good Need Resolved Entry Gate Locked • Good Need Resolved Well Name • Good Need Resolved Site Surface • Good Need Resolved 24hr.Phone No • Good Need Resolved Stains • Good Need Resolved RRC&Api No Good Need • Resolved Trash/Debris • Good Need Resolved No Smoking • Good Need Resolved Weeds/Brush • Good Need Resolved Reflective/Lighting • Good Need Resolved Oders/Fumes/Dust • Good Need Resolved Wellhead Sign Good Need Resolved Site Lighting • Good Need Resolved Tank Battery Sign Good Need Resolved Landscaping • Good Need Resolved Storage Tank Labels Good Need • Resolved Erosion Control • Good Need Resolved Facility Equipment I Miscellaneous I Wellhead Paint • Good Need Resolved Electric Lines Safe • Good Need Resolved Wellhead Leaks • Good Need Resolved Pipeline Markers • Good Need Resolved Tank Battery Paint • Good Need Resolved Layout Per Site Plan • Good Need Resolved Tank Battery Leaks Good Need • Resolved Tank Integrity Good Need • Resolved No Wells Approved Db Level @ Inspection Containment Integrity • Good Need Resolved Fire Dept. Drip Pots@ Load • Good Need Resolved Lightning Arresting • Good Need Resolved Fire Lane Access Referred Tank Level Activated Referred Equip Height • Good Need Resolved Foam Lines Referred Pit Fencing Referred Accessible ESD Referred Auto Safety Valve Referred Inspection Comments I RRC ID#Needed on entry sign, Chem Tank needs Hazcom Label. At compress-dv controller venting. operator attempted to repair during inspection still venting. Middle tank has small hole in top of tank. On 1/4/19, RW conducted a re-inspection. Operator addressed —issues