2020.05.11_COD_FollowUp Gas Well Inspection Type 2020 Annual Inspections Inspection Cycle 1st Half _ DENTON 24hr Phone 817-841-8885 Well Operator Bedrock Inspection Date 4-20-20 Record Active Padsite Name 8 BAKER 1 Close Date 4-28-20 Jurisdiction CoD Lnc Re-Inspection Date 4-28-20 Site Address 4302 Hampton Rd. Padsite Type Single Well Rt 03 2nd Re-Inspection Date Ordinance Reg 2001-465 R Weatherby Inspected by y Inspection Status Closed Plat/Site Permit No Plan No Lease Name .RRC Id Ali No. Spud Date Impact 1108-0305 No Record BAKER 1 190295 12131380 1/30/2002 Moderate MPECTION CHECK LIST Signs/Labels General Location Facility Equipment Operator • Good Need Resolve Wellhead Paint • Good Need Resolve p Fencing • Good Need Resolve Site Address • Good Need Resolve Wellhead Leaks • Good Need Resolve Well Name • Good Need Resolves Entry Gate • Good Need Resolve Site • Good Need Resolve T Battery Paint • Good Need Resolve 24hr. Phone • Good Need Resolves Stains • Good Need Resolve T Battery Leaks Good Need • Resolve RRC/A i# • Good Need Resolve Tank Integrity Good Need • Resolve p� Trash/Debris • Good Need Resolve Containment • Good Need Resolve No Smoking • Good Need Resolves Weeds/Brus • Good Need Resolve Reflective • Good Need Resolves Oders/Fumes/Dus • Good Need Resolve Drip Pots • Good Need Resolve Wellhead • Good Need Resolves Site Lighting • Good Need Resolve Lightning • Good Need Resolve • Good Need Resolve Equip Height • Good Need Resolve Tank Battery Landscaping • Good Need Resolve Tank Labels • Good Need Resolves Erosion • Good Need Resolve INO Wells Approved Db Level Miscellaneous Electric Lines • Good Need Resolve Pipeline • Good Need Resolves Layout • Good Need Resolves Markers per Site IInspection Comments I Meco Regulator at suction controller to Compressor venting -needs repair(red flagged). Thief Hatch on Tank 583-2 (C)venting-needs repair. On 4/28/20, RW conducted a followup inspection. Operator resolved issues Inspections Conducted by Third Party and COD Follow Up Third Party Inspection Date: 3-25-20 COD Follow Up Date: 4-20-20 Leaks:AST A thief hatch, _ Leaks at thief hatches on AST C thief hatch,AST E Lywnd: Tanks A,E,G were tested thief hatch,AST G thief A Q w.1 and found working hatch and enardo valve, C seoo.,ot properly. Thief Hatch at AST H enardo valve,AST 1 Tank C was found venting, enardo valve,and AST J AST 4/28/20 Thief hatch C was enardo valve C °oiWe"°" repaired and working !� AndtaryEwp"M properly ® Upw 0 A.Sampanq Purl '® D—..d A.Sampung Pont 8 --■.-r * V11nd DNNLdI 1101 c D E p a A •• iencel—Saeemnp Mgt ce t C E A O A■ OCservaean Pam E D f N A E Q Padsd. ® a Deem Cwmy Pycets •. I