Oil and Gas Pipeline
Oil and Gas Pipeline License Agreement Checklist
Page 1 of 2
Updated 4/22/21
PLANNING AND DEVELOPMENT DEPARTMENT
City Hall – 401 N. Elm St. – Denton, Texas 76201 voice:(940) 349-8541 fax:(940) 349-7707
www.cityofdenton.com
Please note that this checklist is intended to assist developers and design professionals in the preparation of submittals for
DRC review and are generally what is needed to facilitate the review of the proposed Oil and Gas Pipeline License
Agreement. A submittal of a complete application will facilitate a timely review. Failure of the applicant to provide required
information or obtain a waiver from the DRC Chair will result in application not being processed. Under special
circumstances, additional items may be required through the Development Review Committee process prior to approval.
Items to be submitted with Application:
Universal Application
Associated Fee(s): An initial application review fee of $1000, plus an additional application review fee of $500 for each
instance the proposed pipeline traverses a public street right-of-way within the jurisdiction of the City of Denton and a
$250 application review fee for each instance the pipeline traverses a City of Denton public easement tract. The fee(s)
shall be paid at the front desk of the Planning Department at the time of initial submission. If application is submitted by
mail or other means, then payment of the fee(s) shall accompany the application in the form of a check, made payable to
the City of Denton, with the submission package being sent to the Planning and Development Department at the address
stipulated above. These fees are non-refundable. Applicant acknowledges, demonstrated by their signature(s) herein
and submission of the accompanying City of Denton Development Services Universal Application form, that payment of
the application review fee(s) in no way obligates the City to grant the use requested within public property. (For Staff
information only: Deposit review and processing fee(s) into Account # 6300.5150 Real Estate Application and Processing
Fees).
Project Narrative: Written proposal from the petitioner(s) which describes a general overview of the scope and locations
of the proposed pipeline project and a listing of the accompanying application support materials that will provide the most
practicable details to the following requirements:
1. A full set of construction plans and specifications signed and sealed by a professional engineer, showing the proposed
location, course, and alignment of the proposed pipelines(s) within the jurisdiction of the City of Denton;
2. Additional information in regard to the pipe material type, pipe specifications, schedule timing, manner, means and
method of the proposed pipeline construction, the particular commodity proposed to be transported in the pipeline(s)
and the maximum pressure and maximum temperature under which the same may be pumped or otherwise caused or
be permitted to flow through any and all of the particular portions of the pipeline(s) and design type and locations of
any proposed cathodic protection systems;
3. Maps, schematic drawings, profile views and the like showing the specific installation location of the pipeline, to
include both horizontal and vertical relationship at each street right-of-way crossing and/or longitudinal installation,
as well as the same for instances where the proposed pipeline is to cross public easement(s). Specifically, an 8 ½ x 11
inch sized detail sheet for each instance the proposed pipeline crosses a public street right-of-way or public easement.
This detail sheet shall have a schematic plan view: (1) depicting the limits of the street right-of-way lines or easement
lines to a measurable scale, (2) depicting the precise location of the proposed pipeline within the street right-of-way
or easement limits, a distance tie shall also be annotated on the drawing locating the proposed pipeline in relation to
an intersecting road centerline or deed/plat referenced property corner , (3) depicting a dimension length of the linear
footage of proposed pipeline within the street right-of-way or easement tract, (4) depicting the precise location and
type of any exiting utility facilities, pavement configurations or other material improvements within the street right-of-
way or public easement tract, (5) depicting the proposed location of all pipeline location markers to be placed within
the public street right-of-way or easement tract. This detail sheet shall also have a schematic profile view: (1)
depicting the limits of the street right-of-way lines or easement lines to a measurable scale, (2) depicting the precise
location of the proposed pipeline within the street right-of-way or easement limits, (3) depicting a dimension length of
the linear footage of proposed pipeline within the street right-of-way or easement tract, (4) depicting the precise
location and type of any exiting utility facilities, top of pavement and edges of pavement, or any other material
improvements within the street right-of-way or public easement tract. The individual 8 ½ x 11 inch sized detail
sheet(s) shall each be titled by either street name or overall pipeline project stationing number range.
Oil and Gas Pipeline License Agreement Checklist
Page 2 of 2
Updated 4/22/21
PLANNING AND DEVELOPMENT DEPARTMENT
City Hall – 401 N. Elm St. – Denton, Texas 76201 voice:(940) 349-8541 fax:(940) 349-7707
www.cityofdenton.com
4. In applications involving multiple crossing events of public street right-of-ways and easements, then a separate
“Roster of Crossings” schedule is required. This schedule shall specifically describe each crossing event by provision
of project stationing range for each crossing instance, provide linear footage for each individual pipeline crossing
event of the public street or easement, provide a written description of the crossing type, and a column showing the
fee amount required for each crossing instance.
5. The diameter, normal operating pressure range and the maximal allowable operating pressure of any such existing
pipeline(s) within the City that the proposed subject pipeline is to connect;
6. The specific location of pipeline shut-off valves for each pipeline segment installation proposed to traverse or to be
longitudinally installed within a City of Denton public street right-of-way and the specific location of pipeline shut-off
valves for each existing pipeline that is to be connected to the proposed pipeline(s);
7. The business address and telephone number(s) of the person(s) responsible for the day-to-day operation of subject
proposed pipeline(s);
8. The business address and telephone number(s) of the owner of each existing pipeline slated for connection to the
proposed pipeline(s);
9. The telephone number(s) of at least one (1) emergency contact person available on a 24-hour on-call basis.
Traffic control plan for any proposed work within City of Denton public street right-of-way in accordance with the Texas
Manual of Uniform Traffic Control Devices.
Oil and Gas Pipeline License Agreement Checklist: I have reviewed the checklist and all submittals for completeness
and accuracy.
_______________________________________________ _ ______________________
Signature Date
_______________________________________________ _
Print Name
Questions regarding this type of action request and the respective application requirements are best directed to: