Loading...
1976-052AN ORDINANCE ADDING TO THE CODE OF ORDINANCES OF THE CITY OF DENTON, TEXAS, A NEW CHAPTER 16 ENTITLED "MECHANICAL CODE" REGULATING THE INSTALLATION, ALTERATION, REPAIRS AND MAINTENANCE OF HEATING, VENTI- LATING, COOLING, AND REFRIGERATION SYSTEMS, INCINERATORS AND MIS- CELLANEOUS HEAT PRODUCING APPLIANCES IN ALL BUILDINGS AND STRUCTURES WITHIN T~{E CITY, DEFINING ADMINISTRATIVE RESPONSIBILITY, PROVIDING FOR PERMITS AND FEES, PROVIDING ALTERNATIVE REQUIREMENTS, ESTABLISH- ING A MECHANICAL CODE, AND ADOPTING CERTAIN INSTALLATION REQUIREMENTS AND APPENDICES, MAKING THIS ORDINANCE CUMULATIVE OF PRIOR ORDINANCES, REPEALING ALL ORDINANCES AND PROVISIONS OF THE CODE IN CONFLICT HERE- WITH, PROVIDING A SEVERABILITY CLAUSE, PROVIDING A PFNALTY, AND PRO- VIDING AN EFFECTIVE DATE THE COUNCIL OF THE CITY OF DENTON, TEXAS, HEREBY ORDAINS PART I That the Code of Ordinances of the Czty of Denton, Texas, ~s hereby amended by adding a new Chapter 16 "Mechanical Code", and at shall hereafter read as follows "ARTICLE I IN GENERAL SECTION 16-1 COMPLIANCE WITH UNIFORM MECHANICAL CODE, 1973 EDITION, REQUIRED The Unlform Meohanlcal Code, 1973 Edltlon, coples of whlch are on fale ~n the off~ce of the C~ty Secretary, ~s hereby adopted and designated as the Mechanical Code of the C~ty of Denton, the same as though sa~d volu~e of such code were cop~ed at length hereln, subject to the deletlons and amendments enumerated hereafter SECTION 16-2 AMENDMENTS TO THE UNIFOR~ MECHANICAL CODE 1973 EDITION The Un~form Mechanloal Code, 1973 Edition, as hereby amended as follows (1) SECTION 202 - Amend Paragraph (2) Change amount of fane from $500 00 to $200 00 and delete "or by lmpr~sonment for no more than slx months, or by both such f~ne and ~mprasonment" (2) SECTION 203 - Delete as written and amend to read The Plumb~na and Mechan~oal Code Board as created by Ordanance No 75-51 is hereby adopted as the Board of Appeals for the Mechanical Code (3) SECTION 306 - Add to Paragraph (1) The anspectlon shall be made wlthan twenty-four (24) hours after such notlflcatlon, Saturday, Sunday, and holidays excepted (4) SECTION 503 - Add to Paragraph (2) The valve shall be an iron or brass core cock (5) SECTION 505 - Delete sentence (1) and (2) and add Every attic or furred space ~n which a warm aar furnace ls lnstalled shall be readily accessible by an openlnq and passageway as large as the largest p~ece of the furnace and an no case less than 30" X 22" con- t~nuous from the opening to the furnace and ~ts controls (6) SECTION 705 - Add Paragraph (4) Top plates on partitions shall not be cut unless a 16 gauge X 3" steel header strap havang two nail holes an each end ~s used to tae the cut plates together (7) SECTION 710(e) Delete as written and amend to read Every appliance on a roof of a building shall be ~nstalled on a sub- stantlal level support No appliance shall be installed on a roof that has a slope greater than 5" vertically to 12" horlzontally un- less an appropriate working platform ~s ~nstalled ~n compliance w~th State Safety Codes (8) SECTION 1004(a) - Add to Paragraph (1) Plplng, wlre, conduat, vent p~pes or structural members shall not be w~th~n the aar stream of a supply air duct Where vent papes serving the plumbing system, vents serving heat producing appllances, natural gas p~plng or other piping oonvey~ng hazardous materials or ob]eot- · onable fumes would occur in the return aar system they shall be enclosed ~n a suitable sleeve at least one ~nch larger than the plpe enclosed ~n the sleeve (9) SECTION 1004(b) - Add to Paragraph (2) Joants between non-metallic duct sectlons other than manufacturer for use w~thout a relnforo~ng sleeve, shall be re~nforced with galvanized metal sleeves, extendang at least 4" into the ducts -2- (10) SECTION 1005 - Add to Paragraph (1) Insulation facing shall be legably marked by manufacturer an repeat patterns not over three feet apart or by retaaned roll labels lndacatang has product ldentafacataon, densaty, thaakness, and type vapor barraer (11) TABLE 10E PART II - Amended Delete No 18 gauge steel wire and add No 14 gauge steel ware (12) SECTION 1511 - Add to last paragraph or use specaal fattlngs manufactured for the purpose (13) SECTION 1513 - Delete sentence (1) and amend to read ~ stop valve shall be anstalled at the followang locataons an refrigerant papang of every bualt-up refrageratlon system of 5 h p or larger with accessible type compressors, excludang factory pre-packaged equipment PART II That af any sectaon, s~bsectaon, paragraph, sentence, clause, phrase or word ~n thas ordanance, or appl~cataon thereof to any per- son or carcumstances as held anvalld by any court of competent ]uras- daatlon, such holdang shall not affect the valadaty of the remaanang portaons of thas ordanance, and the Caty Council of the City of Denton, Texas, hereby declares it would have enacted such remaanang portaons despate any such anvaladaty PART III Any person who vaolates any provas~on of thas ordanance shall be deemed gualty of a m~sdemeanor, and, upon conv~ctlon, shall be punished by a fane not to exceed Two Hundred Dollars ($200 00) Each day such a v~olataon shall contanue or be permitted, shall be treated as a separate offense PART IV That thas ordanance shall become effectave fourteen (14) days from the date of ats passage, and the City Secretary as hereby d~rected to oause the caption of thas ordinance to be publashed -3- twice ~n the Denton Record-Chronicle, the official newspaper of the C~ty of Denton, Texas, w~th~n ten (10) days of the date of its passage PASSED AND APPROVED Thls the 23rd day of November, A D , 1976 ELINOR HUGHES ~ M~OR CITY OF DENTON, TEXAS ATTES~ ~OKS HOLT, CITY SECR~ AR CITY OF DENTON, TEXAS APPROVED AS TO LEGAL FORM PAU~ ~ ISHA/~;--C T CITY OF DENTON, TEXAS -4-