Loading...
1975-051NO 95 -51 AN ORDINANCE AMENDING CHAPTER 17 "DENTON PLUMBING CODE" OF THE CODE OF ORDINANCES OF THE CITY OF DENTON, TEXAS, BY AMENDING CERTAIN SEC- TIONS OF THE CODE, REPEALING ALL ORDINANCES AND PROVISIONS OF THE CODE IN CONFLICT HEREWITH, PROVIDING A SEVERABILITY CLAUSE, PROVID- ING A PENALTY, AND PROVIDING AN EFFECTIVE DATE THE COUNCIL OF THE CITY OF DENTON$ TEXAS, HEREBY ORDAINS PART I (1) That Chapter 17 "Denton Plumbing Code" of the Code of Ordinances of the City of Denton, Texas, is hereby amended by en- acting the following sections, which shall hereafter read as fol- lows "ARTICLE IV - PLUMBING AND MECHANICAL CODE BOARD SECTION 17-26 CREATION There is hereby created a Plumbing and Mechanical Code Board consisting of seven members, each to be appointed by the City Council for a term of two years, and removable for cause by said Council Initially, however, three members shall be appointed for a term of one year and four members shall be appointed for two year terms To the extent that persons are available within this city, the said board shall consist of two licensed master plumbers, two mechanical contractors, two mechanical engineers, and one lay- man, who shall all reside within the city The initial terms for the members shall be staggered whereby one master plumber, one mechanical engineer, and one mechanical contractor shall have terms expiring on the odd number years, and one master plumber, one mech- anical engineer, one mechanical contractor, and the layman shall have terms expiring on the even number years No appointed member shall serve more than three consecutive terms The City Council may appoint ex officio members to this board, to have a voice in all matters before it, but who shall have no vote " (2) ARTICLE V, CHAPTER 3, SECTION 313 EXCEPTIONS is hereby deleted and amended by adding a new "Exceptions" to said Section 313, which shall hereafter read as follows G- "SECTION 313 - EXCEPTIONS More than one building may be connected to the same building sewer when all of the following conditions are met (1) Prior approval by the administrative authority (2) When all buildings to be connected to the sewer are located on the same lot or tract of land (3) When all applicable provisions of this code are complied with " (3) ARTICLE V, CHAPTER 4, SECTION 413, TABLE 4-1 is hereby amended by changing the minimum trap and trap arm size for single wash basins as follows "TABLE 4-1" Trap & Trap Kind of Fixture Arm Size Units Wash Basins (lavatories) single 1-1/4" 1 (4) ARTICLE V, CHAPTER 6, SECTION 615, TABLE 6-1 is hereby amended by adding 1-1/4" size of fixture drain, which shall hereafter read as follows "TABLE 6-1" Distance of Fixture Trap From Vent Size of Fixture Distance Trap Drain Inches To Vent 1-1/4" 2 ft 6 in (5) ARTICLE V, CHAPTER 7, SECTION 702, TABLE 7-1 is hereby amended by adding a size of fixture of 1-1/4" to the table, which shall hereafter read as follows "TABLE 7-1" Horizontal Distance of Trap Arms Distance Trap To Vent Feet Inches 1-1/4" 2 6 -2- (6) ARTICLE V, CHAPTER 7, SECTION 703 (c) is hereby deleted and amended by adding a new Section (c) of said article and chapter, which shall hereafter read as follows "SECTION 703 - Traps Described (c) The size (nominal diameter) of a trap for a given fixture shall be sufficient to drain the fixture rapidly, and shall not be less than given in Table 4-1 No trap shall be larger than the trap arm to which it is connected (Floor drain traps serving drains in restaurants, cafes, lunch counters, cafeterias, bars, clubs, kitchens in hotels, hospitals, sanitariums, factories, or schools, or any other establishment where food is prepared, sold, dispensed, or eaten, shall be not less than three inch (3") size (7) ARTICLE V, CHAPTER 9, SECTION 904 is hereby amended by de- leting subsection (b) from Section 904 and the present subsection (c) shall become subsection (b) and the present subsection (d) will be- come subsection (c) (8) ARTICLE V, CHAPTER 10, SECTION 1005 (b) is hereby deleted and amended by adding a new subsection (b) to Sections 1005 of said article and chapter, which shall hereafter read as follows "SECTION 1005 - Valves (b) An approved fullway gate valve, globe valve, ball valve, or lubricating plug cock controlling all outlets shall be installed on the discharge side of each water meter and on each unmetered water supply The valve shall have an operating handle of cast iron, brass, or cadmium-plated steel (not less than one-eighth (1/8) inch thick), and shall be installed as an approved valve box immediately adjacent to the meter box Water piping supplying more than one building on any one premises shall be equipped with a separate such shut-off valve to each building, so arranged that the water supply can be turned on or off to any individual or separate building, pro- vided however, that supply piping to a single family residence and building accessory thereto, may be controlled by one valve Such shut-off valve shall be readily accessible at all times A valve of this type shall be installed on the discharge piping from water -3- supply tanks at or near the tank A valve of this type shall be in- stalled on the cold water supply pipe to each water heater at or near the water heater A valve of this type shall be installed for each apartment or dwelling of more than one (1) family In lieu of the main supply shut-off in each apartment, individual valves may be provided at each fixture (9)I ARTICLE V, CHAPTER 10$ ECTION 1005 (g) is hereby deleted and the present subsection (h) of Section 1005 shall become sub- section (g) (14) ARTICLE V, CHAPTER 10, SECTION 1010, TABLE 10-3 is hereby deletedland amended by adding a new Table 10-3 of said article and chapterk which shall hereafter read as follows "TABLE 10-3" Water Service Line Sizes Minimum NUMBER OF FIXTURE LENGTH OF RUN, METER TO BUILDING UNITS 0'-50 51'-100 101' & UP 1-5 3/4" 3/4" 3/4" 6-10 3/4" 3/4" 11-15 1" 16-20 1" 1-1/4" 21-40 1-1/4" 1-1/4" 2" (11) ARTICLE V, CHAPTER 10, SECTION 1010 TABLE 10-4 is hereby deleted and amended by adding a new Table 10-4 of said article and chapter, which shall hereafter read as follows "TABLE 10-4" Branch Water Line Sizes (minimum) NUMBER OF FIXTURE LENGTH OF RUN OF BRANCH UNITS 01-25 261-50 51' & UP 1 1/2" 1/2" 1/2" 2 1/2" 1/2" 3/4" 3-6 3/4" 3/4" 3/4" 7-10 3/4" 3/4" it, 11-18 1" 1" 1" 19-40 1-1/4" 1-1/2" 1-1/2" -4- twice in the Denton Record-Chronicle, the official newspaper of the City of Denton, Texas, within ten (10) days of the date of its passage PASSED AND APPROVED This the 16th day of December, A D 1975 =k A J .1~ MAYOR CITY OF DEN N, T S ATTEST, BMqKS DOLT; CITY SECRETARY C T OF DENTON, TEXAS APPROVED AS TO LEGAL FORM PAUL C ISHAM, CITY AT OWN Y CITY OF DENTON, TEXAS -6-