Loading...
1993-160FILE REFERENCE FORM 93-160 X Additional File Exists Additional File Contains Records Not Public, According to the Public Records Act Other FILES Date Initials Amended by Ordinance No. 94-098 09/14/93 )R j:\wpdocs\ord\94e1rate 23 NOTE: This Ordinance has been ORDINANCE NO. amended by Ordinance No. 94-098 AN ORDINANCE AMENDING THE SCHEDULE OF ELECTRIC RATES; PROVIDING FOR A SEVERABILITY CLAUSE; AND PROVIDING FOR AN EFFECTIVE DATE. THE COUNCIL OF THE CITY OF DENTON HEREBY ORDAINS: SECTION I. That the Schedule of Rates for electrical services as provided for in Chapter 26 of the Code of Ordinances, is amended to read as follows: ARTICLE I. ELECTRIC RATE SCHEDULES PAGE R1 Residential Service Rate 2 R2 Residential Service Rate 4 GSL General Service Large 6 GSS General Service Small 9 EWK Experimental Weekend 12 G1 Local Government Lighting & Power Service Rate 15 (City, County, Independent School District) TR Residential Time of Use Rate 18 TGS General Service Time of Use Rate 20 LS Street Lighting 24 LO Other Lighting 26 LT Traffic Lighting 28 DD Dusk-to-Dawn Lighting (Security Light) 29 T1 Temporary Service Schedule 31 P1 Interruptible Primary Service 33 AF Athletic Field 36 ES Standby, Supplementary & Maintenance Service 38 DL Decorative Lighting 43 IDR Industrial Development Rate 44 TS Thermal Storage Rate 45 UPS Uninterruptible Power Supply 46 ECA Energy Cost Adjustment 48 APR Appliance Rebate 49 ACR Air Conditioner Cycling Rebate 54 VLR Voluntary Load Reduction 55 SCHEDULE R1 RESIDENTIAL SERVICE (Effective 10/01/93) APPLICATION Applicable to all electric service used for residential pur- poses in a single family dwelling or an individually metered apart- ment; supplied at one point of delivery and measured through one meter where usage is not in excess of 700 KWH per 30-day month dur- ing the billing months MAY through OCTOBER. If usage in any such month exceeds 700 KWH, billing will be rendered that month under Rate Schedule R-2 and thereafter for a period extending through the 12 billing months of the next year ending with the October billing. Annually, in November, the customer may again qualify for the R-1 rate provided that consumption has not exceeded 700 KWH per 30-day month during the previous six summer months. Where individual dwelling units are being served through the same meter and the KWH in the billing months of MAY through OCTOBER exceed 700 KWH times the number of dwelling units, the billing for that month and thereafter will be rendered under Rate Schedule R-2. NET MONTHLY RATE (1) Customer Facility Charge $6.65/30 days (2) Energy Charge 4.30/KWH (3) Energy Cost Adjustment Schedule ECA MINIMUM BILLING $6.65/30 days TYPE OF SERVICE The City will supply single-phase service at any standard volt- ages available from the City's distribution system through one standard transformation. PAYMENT Bills are due when rendered, and become past due if not paid within 15 calendar days from date of issuance. SPECIAL FACILITIES All services which require special facilities in order to meet customer's service requirements shall be provided subject to the special facilities rider. PAGE 2 PRORATION OF UTILITY BILLS Billing for the Facility charge shall be based on 12 billings annually. Formula: Actual days in reading period x customer facility charge 30 days ENERGY CHARGE Billing for the energy charge shall be based on actual KWH con- sumption during the billing period. Formula: KWH in rate block x Rate per KWH in rate block ENERGY COST ADJUSTMENT A charge per KWH of energy taken for fuel cost calculated in accordance with Schedule ECA. PAGE 3 SCHEDULE R2 APPLICATION Applicable to any customer for all electric service used for residential purposes in an individual private dwelling or an indi- vidually metered apartment, supplied at one point of delivery and measured through one meter. Not applicable to resale service in any event, nor to tempo- rary, standby, or supplementary service except in conjunction with applicable rider. NET MONTHLY RATE WINTER RESIDENTIAL SERVICE (Effective 10/01/93) Billing months of NOV through APRIL SUMMER Billing months of MAY through OCT (1) Customer Facility Charge Single Phase Three Phase $ 7.65/30 days $15.30/30 days $ 7.65/30 days $15.30/30 days (2) Energy Charge First 1,000 KWH Additional KWH First 3,000 KWH Additional KWH (3) Energy Cost Adjustment 4.300/KWH 3.900/KWH Schedule ECA 5.550/KWH 6.150/KWH Schedule ECA MINIMUM BILLING Single Phase Three Phase $ 7.65/30 days $15.30/30 days $ 7.65/30 days $15.30/30 days TYPE OF SERVICE The City will supply single-phase service (or three-phase ser- vice if available at the point of delivery) at sixty (60) cycles and at any standard voltages available from the City's distribution system through one standard transformation. Where service of the type desired by the customer is not already available at the point of service, special contract arrangements between the City and the customer may be required in advance. PAGE 4 PAYMENT Bills are due when rendered, and become past due if not paid within 15 calendar days from date of issuance. SPECIAL FACILITIES All services which require special facilities in order to meet customer's service requirements shall be provided subject to the special facilities rider. PRORATION OF UTILITY BILLS Billing for the Facility charge shall be based on 12 billings annually. Formula: Actual days in reading period x customer facility charge 30 days ENERGY CHARGE Billing for the energy charge shall be based on actual KWH con- sumption during the billing period. Formula: KWH in rate block x Rate per KWH in rate block ENERGY COST ADJUSTMENT A charge per KWH of energy taken for fuel cost calculated in accordance with Schedule ECA. PAGE 5 SCHEDULE GSL GENERAL SERVICE LARGE (Effective 10/01/93) APPLICATION The GSL Rate is applicable to any customer having a minimum actual demand of 250 KW for all electric service supplied at one point of delivery and measured through one meter. Customers with an average actual demand equal to or greater than 180 KW during the previous twelve month period may be allowed service under this rate, subject to the minimum billing provision. Customers who elect to discontinue service under this rate are ineligible for service under this rate for twelve months. Not applicable to resale service in any event, nor to tempo- rary, standby or supplementary service except in conjunction with applicable rider. NET MONTHLY RATE (1) Customer Facility Charge (2) Demand Charge (3) Energy Charge (4) Energy Cost Adjustment $60.00 per 30 days $ 9.50 per KW of demand per 30 days 1.400/KWH for all KWH Schedule ECA MINIMUM BILLING An amount equal to the facility charge plus the greater of: 1) demand charge as calculated on 250 KW, or 2) seventy percent (700) of the maximum monthly demand charge for any month during the pre- ceding months of May through October. TYPE OF SERVICE Secondary or primary service available to commercial and indus- trial customers. Primary service is rendered at one point on the customer's premises at a nominal voltage of 13,200 volts. PRIMARY SERVICE DISCOUNT Customers who own, operate, and maintain all facilities neces- sary to receive three phase primary voltage service and all trans- formation facilities required for conversion to utilization voltage shall receive a discount of 0.3(~/KWH. Primary service customers utilizing City owned and operated facility and transformation PAGE 6 equipment necessary to receive primary voltage service shall receive a discount of 0.14/KWH. The City shall own, operate and maintain all metering facilities, either at primary or secondary voltage. PAYMENT Bills are due when rendered, and become past due if not paid within 15 calendar days from date of issuance. DETERMINATION OF DEMAND The demand shall be determined by the KW supplied during the 15-minute period of maximum use during the current month as deter- mined by City's demand meter, but shall not be less than 700 of the highest monthly demand determined during the billing months of MAY through OCTOBER in the 12 months immediately preceding the current month. POWER FACTOR The City reserves the right to make tests to determine eligi- bility for the GSL rate, and to determine the power factor of the customer's installation served either by measurement during periods of maximum demand or by measurement of the average power factor for the monthly billing period. If the power factor is below ninety percent, the demand for billing purposes will be determined by multiplying the uncorrected KW billing demand by 90% and dividing by the determined power factor. SPECIAL FACILITIES All services which require special facilities in order to meet customer's service requirements shall be provided subject to the special facilities rider. PRORATION OF UTILITY BILLS (a) Billing for the Facility charge shall be based on 12 bill- ings annually. Formula: Actual days in reading period 30 days x customer facility charge PAGE 7 (b) Billing for demand shall be calculated on a 30 day per month basis and prorated for longer or shorter billing periods. Formula: Actual days in reading period x KW demand x Rate 30 days ENERGY CHARGE Billing for the energy charge shall be based on actual KWH con- sumption during the billing period. Formula: KWH in rate block x Rate per KWH in rate block ENERGY COST ADJUSTMENT A charge per KWH of energy taken for fuel cost calculated in accordance with Schedule ECA. PAGE 8 SCHEDULE GSS GENERAL SERVICE SMALL (Effective 10/01/93) APPLICATION The GSS rate is applicable to any commercial or industrial customer having a maximum demand less than 250 KW for all electric service supplied at one point of delivery and measured through one meter. Not applicable to resale service in any event, nor to tempo- rary, standby or supplementary service except in conjunction with applicable rider. NET MONTHLY RATE (1) Customer Facility Charge Single Phase Three Phase (2) Demand Charge $15.00 per 30 days $20.00 per 30 days $ 7.50 per KW (first 20 KW not billed) (3) Energy Charge First 2500 KWH All KWH over 2500 6.70/KWH 3.354"/KWH (4) Energy Cost Adjustment Current ECA Schedule MINIMUM BILLING An amount equal to the facility charge plus the greater of: 1) the demand charge calculated on the actual KW demand, or 2) seventy percent (70%) of the maximum monthly demand charge for any month during the preceding months of May through October. TYPE OF SERVICE Secondary service available to commercial and industrial customers. The City will supply single-phase service (or three-phase ser- vice if available at the point of delivery) at sixty (60) cycles and at any standard voltages available from the City's distribution system through one standard transformation. Where service of the type desired by the customer is not already available at the point of service, special contract arrangements between the City and the customer may be required prior to commencement of service. PAGE 9 PRIMARY SERVICE DISCOUNT Customers who own, operate, and maintain all facilities neces- sary to receive three phase primary voltage service and all trans- formation facilities required for conversion to utilization voltage shall receive a discount of 0.3(~/KWH. Primary service customers utilizing City owned and operated facility and transformation equipment necessary to receive primary voltage service shall receive a discount of 0.1C/KWH. The City shall own, operate and maintain all metering facilities, either at primary or secondary voltage. PAYMENT Bills are due when rendered, and become past due if not paid within 15 calendar days from date of issuance. DETERMINATION OF DEMAND The demand shall be determined by the KW supplied during the 15-minute period of maximum use during the current month as deter- mined by City's demand meter, but shall not be less than 70% of the highest monthly demand determined during the billing months of MAY through OCTOBER in the 12 months immediately preceding the current month. In cases where the connected load is constant, the City may, at its option, estimate the KW demand. For neon signs, one volt am- pere shall be considered the equivalent of 3/4 watt. POWER FACTOR The City reserves the right to make tests to determine the power factor of the customer's installation served either by measurement during periods of maximum demand or by measurement of the average power factor for the monthly billing period. If the power factor is below ninety percent, the demand for billing pur- poses will be determined by multiplying the uncorrected KW billing demand by 90% and dividing by the determined power factor. SPECIAL FACILITIES All services which require special facilities in order to meet customer's service requirements shall be provided subject to the special facilities rider. PAGE 10 PRORATION OF UTILITY BILLS (a) Billing for the Facility charge shall be based on 12 bill- ings annually. Formula: Actual days in reading period x customer facility charge 30 days (b) Billing for demand shall be calculated on a 30 day per month basis and prorated for longer or shorter billing periods. Formula: Actual days in reading period x adjusted KW demand x Rate 30 days ENERGY CHARGE Billing for the energy charge shall be based on actual KWH con- sumption during the billing period. Formula: KWH in rate block x Rate per KWH in rate block ENERGY COST ADJUSTMENT A charge per KWH of energy taken for fuel cost calculated in accordance with Schedule ECA. PAGE 11 SCHEDULE EWK EXPERIMENTAL WEEKEND RATE (EFFECTIVE 10/01/93) APPLICATION Applicable to any commercial and industrial user whose maximum demand load occurs during the period from Thursday at 12 midnight through Sunday at 12 midnight and does not experience a demand load during the period from Sunday 12 midnight through Thursday 12 mid- night that exceeds 80% of the maximum demand load. Customers who violate the 80% requirement more than four times during the month, or more than twice on the same day of the week, during the months of June through September are ineligible for ser- vice under this rate for twelve (12) months. Not applicable to resale service in any event, nor to tempo- rary, standby or supplementary service except in conjunction with applicable rider. NET MONTHLY RATE (1) Customer Facility Charge $22.00/30 days--Single Phase $27.00/30 days--Three Phase (2) Demand Charge (3) Energy Charge First 2,500 KWH All over 2,500 KWH (4) Energy Cost Adjustment MINIMUM BILLING $ 6.00/KW (first 20 KW not billed) 6.70/KWH 3.350/KWH Per Schedule ECA An amount equal to the demand charge as calculated below plus $22.00/month for single phase service or $27.00/month for three phase service, per 30 day billing. TYPE OF SERVICE The City will supply single-phase service (or three-phase ser- vice if available at the point of delivery) at sixty (60) cycles and at any standard voltages available from the City's distribution system through one standard transformation. Where service of the type desired by the customer is not already available at the point of service, special contract arrangements between the City and the customer may be required. PAGE 12 PAYMENT Bills are due when rendered and become past due if not paid within 15 calendar days from date of issuance. DETERMINATION OF DEMAND The demand shall be determined by the KW supplied during the fifteen (15) minute period of maximum use during the current month as determined by the City's demand meter. Billing shall be based on an adjusted KW demand, which is the actual demand less 20 KW. The adjusted KW demand will subsequently be used for billing the demand portion of the utility bill. SPECIAL FACILITIES All services which require special facilities in order to meet customer's service requirements shall be provided subject to the special facilities rider. PRORATION OF UTILITY BILLS Billing for customer facility charge and demand shall be calcu- lated on a 30-day basis and prorated for longer or shorter billing period. (a) Billing for the Customer Facility Charge shall be based on 12 billings annually. Formula: Actual days in reading period x customer facility charge 30 days (b) Billing for the Demand Charge shall be based on 12 bill- ings annually. Formula: Actual days in reading period x adjusted KW demand x Rate 30 days ENERGY CHARGE Billing for the energy charge shall be based on actual KWH con- sumption during the billing period. PAGE 13 Formula: KWH in rate block x Rate per KWH in rate block ENERGY COST ADJUSTMENT A charge per KWH of energy taken for fuel cost calculated in accordance with Schedule ECA. PAGE 14 SCHEDULE G1 LOCAL GOVERNMENT (Effective 10/01/93) APPLICATION Applicable to any local City, County or School District for all electric service supplied at one point of delivery and measured through one meter. Not applicable to resale service in any event, nor to tempo- rary, standby or supplementary service except in conjunction with applicable rider. NET MONTHLY RATE (1) Customer Charge Single Phase Three Phase (2) Demand Charge (3) Energy Charge (4) Energy Cost Adjustment $15.00 per 30 days $20.00 per 30 days $ 6.25 per KW of demand 3.00 per KWH for all KWH Current ECA Schedule MINIMUM BILLING An amount equal to the demand charge as calculated below but not less than fifty percent (50%) of the maximum monthly demand charge for any month during the preceding months of May through October plus $15.00/month for single phase service or less than $20.00/month for three phase service, per 30 day billing period. TYPE OF SERVICE The City will supply single-phase service (or three-phase ser- vice if available at the point of delivery) at sixty (60) cycles and at any standard voltages available from the City's distribution system through one standard transformation. Where service of the type desired by the customer is not already available at the point of service, special contract arrangements between the City and the customer may be required. PAYMENT Bills are due when rendered, and become past due if not paid within 15 calendar days from date of issuance. PAGE 15 DETERMINATION OF DEMAND The demand shall be determined by the KW supplied during the 15-minute period of maximum use during the current month as deter- mined by City's demand meter. POWER FACTOR The City reserves the right to make tests to determine the power factor of the customer's installation served either by measurement during periods of maximum demand or by measurement of the average power factor for the monthly billing period. If the power factor is below ninety percent, the demand for billing pur- poses will be determined by multiplying the uncorrected KW billing demand by 90% and dividing by the determined power factor. SPECIAL FACILITIES All services which require special facilities in order to meet customer's service requirements shall be provided subject to the special facilities rider. PRORATION OF UTILITY BILLS (a) Billing for the Facility charge shall be based on 12 bill- ings annually. Formula: Actual days in reading period x customer facility charge 30 days (b) Billing for demand shall be calculated on a 30 day per month basis and prorated for longer or shorter billing periods. Formula: Actual days in reading period x KW demand x Rate 30 days ENERGY CHARGE Billing for the energy charge shall be based on actual KWH con- sumption during the billing period. Formula: KWH in rate block x Rate per KWH in rate block PAGE 16 ENERGY COST ADJUSTMENT A charge per KWH of energy taken for fuel cost calculated in accordance with Schedule ECA. PAGE 17 SCHEDULE TR RESIDENTIAL TIME OF USE (Effective 10/01/93) APPLICATION Applicable to any customer for all electric service used for residential purposes in an individual private dwelling or an indi- vidually metered apartment, supplied at one point of delivery and measured through one meter. Customers applying for the TR rate must remain on this rate for twelve (12) continuous billing per- iods. Not applicable to resale service in any event, nor to tempo- rary, standby, or supplementary service except in conjunction with applicable rider. NET MONTHLY RATE (1) Customer Facility Charge Single Phase Three Phase (2) Energy Charge $15.30/30 days $20.40/30 days On-Peak Hours Off-Peak Hours (3) Energy Cost Adjustment MINIMUM BILLING 25.3P' /KWH 1.4(," /KWH Schedule ECA The minimum monthly bill shall be the Customer Facility Charge. TYPE OF SERVICE Single-phase or three-phase at sixty (60) cycles at secondary distribution voltage. Where service of the type desired by the customer is not already available at the point of service, special contract arrangements between the City and the customer may be required prior to commencement of service. DEFINITION OF ON-PEAK HOURS The City's on-peak hours, for the purpose of this rate sched- ule, are designated as being from 2:00 P.M. to 7:00 P.M. each Monday through Friday, starting on June 1 and continuing through September 30 each year. The City's on-peak hours may be changed from time to time and the customer will be notified twelve (12) months before such changes become effective. PAGE 18 DEFINITION OF OFF-PEAK HOURS The City's off-peak hours, for the purpose of this rate sched- ule, shall be all hours not designated as on-peak hours. SPECIAL FACILITIES All services which require special facilities in order to meet customer's service requirements shall be provided subject to the special facilities rider. PRORATION OF UTILITY BILLS Billing for the Facility Charge shall be based on 12 billings annually using the following formula: Actual days in reading period x customer facility charge 30 days ENERGY CHARGE Billing for the energy charge shall be based on actual KWH con- sumption during the billing period. Formula: KWH in rate block x Rate per KWH in rate block ENERGY COST ADJUSTMENT A charge per KWH of energy taken for fuel cost calculated in accordance with Schedule ECA. PAYMENT Bills are due when rendered, and become past due if not paid within 15 calendar days from date of issuance. PAGE 19 SCHEDULE TGS GENERAL SERVICE TIME OF USE (Effective 10/01/93) APPLICATION Applicable to any customer having a minimum demand of 250 KW for all electric service supplied at one point of delivery and measured through one meter, with the City providing all facilities necessary to receive primary voltage service. Supplementary ser- vice will be available subject to the applicable rider. Not appli- cable to resale or temporary service. Customers electing this rate must remain on this rate for a minimum of twelve (12) continuous billing months. NET MONTHLY RATE (1) Customer Facility Charge (2) On-Peak Demand Charge (3) System Demand Charge (4) Energy Charge (5) Energy Cost Adjustment: MINIMUM BILLING $70.00/30 days $10.30/KW of On-Peak Demand $ 4.15/KW of System Demand 0.54/KWH Per Schedule ECA The minimum monthly bill shall be the sum of the Customer Facility Charge, the On-Peak Demand Charge, and the System Demand Charge; but not less than 100% of the maximum monthly total demand charge for any month during the preceding months of May through October. TYPE OF SERVICE Secondary or primary service available to commercial and indus- trial customers. Primary voltage service is available to any cus- tomer with a minimum demand of 250 KW. Primary service is rendered at one point on the customer's premises at a nominal voltage of 13,200 volts. The City will supply single-phase service (or three-phase ser- vice if available at the point of delivery) at sixty (60) cycles and at any standard voltages available from the City's distribution system through one standard transformation. Where service of the type desired by the customer is not already available at the point of service, special contract arrangements between the City and the customer may be required. PAGE 20 PRIMARY SERVICE DISCOUNT Customers who own, operate and maintain all facilities neces- sary to receive three phase primary voltage service and all trans- formation facilities required for conversion to utilization voltage shall receive a discount of 0.34/KWH. If primary service is provi- ded and the City owns and operates all facilities and transforma- tion equipment necessary to receive primary voltage service, a dis- count of 0.14:/KW will be applied to the customer's bill. The City shall own, operate and maintain all metering facilities, either at primary or secondary voltage, at the City's option. DETERMINATION OF ON-PEAK DEMAND The on-peak demand shall be determined by the KW demand sup- plied during the fifteen (15) minute period of maximum use each month during on-peak hours as recorded by the City's demand meter and adjusted for power factor, but not less than one hundred per- cent (100%) of the maximum on-peak demand similarly determined dur- ing the billing months of June through September in the twelve (12) months immediately preceding the current month. The on-peak demand will be billed every month. DETERMINATION OF SYSTEM DEMAND The system demand shall be determined by the maximum KW demand supplied during the fifteen (15) minute period of maximum use each month as recorded by the City's demand meter and adjusted for power factor, but not less than one hundred percent (100%) of the maximum system demand similarly determined during the billing months of June through September in the twelve (12) months immediately prece- ding the current month. POWER FACTOR PENALTY The City reserves the right to make tests to determine the power factor of the customer's installation served either by mea- surement during periods of maximum demand or by measurement of the average power factor for the monthly billing period. If the power factor is below ninety percent, the demand for billing purposes will be determined by multiplying the uncorrected KW billing demand by 90% and dividing by the determined power factor. DEFINITION OF ON-PEAK HOURS The City's on-peak hours, for the purpose of this rate sched- ule, are designated as being from 2:00 P.M. to 7:00 P.M. each Monday through Friday. The City's on-peak hours may be changed from time to time and the customer will be notified twelve (12) months before such changes become effective. PAGE 21 DEFINITION OF OFF-PEAK HOURS The City's off-peak hours, for the purpose of this rate sched- ule, shall be all hours not designated as on-peak hours. SUPPLEMENTAL POWER RIDER Customers requesting standby or supplementary power shall be allowed service under this rate schedule; however, the determina- tion of system demand shall be adjusted to read: The system demand shall be the sum of the maximum KW demand supplied during the fifteen (15) minute period of maxi- mum use as recorded by the City's demand meter plus the KW nameplate rating(s) of the customer's generator(s). In the event the customer's generator(s) is/are off-line at the time of the establishment of the maximum system demand, the KW nameplate rating of the generator(s) unavailable for service shall be removed from the determination of the system demand. In no event shall the system demand be less than one hundred percent (100%) of the maximum system demand similarly deter- mined during the billing months of June through September in the twelve (12) months immediately preceding the current month. SPECIAL FACILITIES All services which require special facilities in order to meet the customer's service requirements shall be provided subject to special facilities rider. PRORATION OF UTILITY BILLS (a) Billing for the Facility Charge shall be based on 12 bill- ings annually using the following formula: Actual days in reading period x customer facility charge 30 days (b) Billing for demand shall be calculated on a 30-day-per- month basis and pro rated for longer or shorter billing periods using the following formula: Actual days in reading period x KW Demand X Rate 30 days ENERGY CHARGE Billing for the energy charge shall be based on actual KWH con- sumption during the billing period. Formula: KWH in rate block x Rate per KWH in rate block PAGE 22 ENERGY COST ADJUSTMENT A charge per KWH of energy taken for fuel cost calculated in accordance with Schedule ECA. PAYMENT Bills are due when rendered, and become past due if not paid within 15 calendar days from date of issuance. PAGE 23 SCHEDULE LS STREET LIGHTING (Effective 10/01/93) APPLICATION Applicable to all street lighting owned and maintained by the City of Denton. NET MONTHLY RATE (1) Facility Charge (2) Energy Cost Adjustment LS LSA 100W Sodium Vapor LSB 250W Sodium Vapor LSC 400W Sodium Vapor See table Current ECA x Monthly Bulb Wattage Factor Facility Charge Bulb Wattage Factor $ 4.85/30 Days 48 KWH $ 6.90/30 Days 105 KWH $ 8.65/30 Days 159 KWH LM LMA 175W Mercury Vapor LMB 250W Mercury Vapor LMC 400W Mercury Vapor LMD 1000W Mercury Vapor $ 5.60/30 Days 70 KWH $ 6.65/30 Days 98 KWH $ 8.40/30 Days 153 KWH $15.30/30 Days 380 KWH TYPE OF SERVICE The City will supply single-phase service (or three-phase service if available at the point of delivery) at sixty (60) cycles and at any standard voltages available from the City's distribution system through one standard transformation. Where service of the type desired by the customer is not already available at the point of service, special contract arrangements between the City and the customer may be required prior to commencement of service. PAYMENT Bills are due when rendered, and become past due if not paid within 15 calendar days from date of issuance. PAGE 24 PRORATION OF UTILITY BILLS Billing for the Facility Charge shall be based on 12 billings annually based on the following formula: Actual days in reading period x # of lights x customer facility 30 days per type charge ENERGY COST ADJUSTMENT A charge per KWH of energy taken for fuel cost calculated in accordance with Schedule ECA. ENERGY CHARGE Billing for the energy charge shall be based on actual KWH consumption per 30 day period for each type of light. PAGE 25 SCHEDULE LO OTHER LIGHTING (Effective 10/01/93) LOA APPLICATION Applicable to State and Local Government agencies that install and maintain their own street lights, other than the City of Denton. BULB WATTAGE MONTHLY RATE FACTOR LS1 250W Sodium Vapor 5.25/KWH 105 KWH LS2 40OW Sodium Vapor 5.25qI/KWH 159 KWH LM1 40OW Mercury Vapor 5.250/KWH 153 KWH LM2 1000W Mercury Vapor 5.250/KWH 380 KWH LOB APPLICATION Applicable to other unmetered lighting services. TYPE OF SERVICE At the City's available secondary voltage and phase. PAYMENT Bills are due when rendered, and become past due if not paid within 15 calendar days from date of issuance. MAINTENANCE CHARGE Maintenance expenses billed at cost. SPECIAL FACILITIES All services which require special facilities in order to meet customer's service requirements shall be provided subject to the special facilities rider. ENERGY COST ADJUSTMENT A charge per KWH of energy taken for fuel cost calculated in accordance with Schedule ECA. PAGE 26 ENERGY CHARGE Billing for the energy charge shall be based on actual KWH consumption per 30 day period for each type of light. Formula: Days in billing period x monthly bulb wattage x # of lights 30 days rate x factor per type PAGE 27 SCHEDULE LT TRAFFIC LIGHTING (Effective 10/01/93) APPLICATION Applicable to State and Local Government agencies that operate and maintain their own traffic signals. NET MONTHLY RATE All KWH 5.25 per KWH TYPE OF SERVICE At the City's available secondary voltage and phase. PAYMENT Bills are due when rendered, and become past due if not paid within 15 calendar days from date of issuance. MAINTENANCE CHARGE Maintenance expenses billed at cost. SPECIAL FACILITIES All services which require special facilities in order to meet customer's service requirements shall be provided subject to the special facilities rider. ENERGY CHARGE Billing for the energy charge shall be based on actual KWH con- sumption during the billing period. Formula: KWH x Rate per KWH ENERGY COST ADJUSTMENT A charge per KWH of energy taken for fuel cost calculated in accordance with Schedule ECA. PAGE 28 SCHEDULE DD DUSK TO DAWN LIGHTING (Effective 10/01/93) APPLICATION Applicable to any customer within the area served by the City's electric distribution system for outdoor area lighting when such lighting facilities are operated as an extension of the City's distribution system. NET MONTHLY RATE (1) Facility Charge See table (2) Energy Cost Adjustment Current ECA x Monthly Bulb Wattage Factor Facility Charge Bulb Wattage Factor DSA 100W Sodium Vapor $ 7.65/30 Days 48 KWH DSB 250W Sodium Vapor $ 9.95/30 Days 105 KWH DSC 400W Sodium Vapor $12.25/30 Days 159 KWH DMA 175W Mercury Vapor $ 6.40/30 Days 70 KWH DMB 250W Mercury Vapor $ 7.45/30 Days 98 KWH DMC 400W Mercury Vapor $ 8.25/30 Days 153 KWH TYPE OF SERVICE The City shall furnish, install, maintain and deliver electric service to automatically controlled, mercury or sodium vapor light- ing fixtures conforming to the City's standards and subject to its published rules and regulations. Where necessary for proper illumination or where existing poles are inadequate, the City will install or cause to be installed, one (1) pole for each installed light, at a distance not to exceed eighty (801) feet from said existing lines, at no charge to the customer. Each additional pole span shall not exceed a span spac- ing of one hundred (1001) feet. Additional poles required to in- stall a light in a customer's specifically desired location, and not having a light installed on same, shall bear the cost. PAYMENT Bills are due when rendered, and become past due if not paid within 15 calendar days from date of issuance. PAGE 29 TERM OF CONTRACT A two (2) year contract shall be agreed to and signed by each customer desiring Dusk-to-Dawn Lighting Service authorizing fixed monthly charges, which may be reviewed annually, and to be applied to the monthly municipal utilities bill. In the event that a cus- tomer desired the removal of the unit or discontinuance of the ser- vice prior to completion of two (2) years, the remainder of the contract period shall become due and payable. After the end of the initial two (2) year contract, service shall continue on a month- to-month basis and may be canceled by either party upon thirty (30) days notice. SPECIAL FACILITIES All service which requires special facilities in order to meet the customer's service requirements shall be provided subject to special facilities rider. PRORATION OF UTILITY BILLS Billing for the Facility charge shall be based on 12 billings annually. Formula: Actual days in reading period X # of lights X customer facility 30 days per type charge ENERGY CHARGE Billing for the energy charge shall be based on actual KWH consumption per 30 day period for each type of light. Formula: Days in billing period X bulb wattage x # of lights 30 days factor per type ENERGY COST ADJUSTMENT A charge per KWH of energy taken for fuel cost calculated in accordance with Schedule ECA. PAGE 30 SCHEDULE T1 TEMPORARY SERVICE (Effective 10/01/93) APPLICATION Applicable when a customer requests electric service on a short term or temporary basis where a customer has received a permit from the City of Denton's Building Inspections Department. This rate is not applicable after the certificate of occupancy has been issued. NET MONTHLY RATE (1) Facility Charge Single Phase Three Phase $15.00/30 days $20.00/30 days (2) Energy Charge (3) Energy Cost Adjustment MINIMUM BILLING TYPE OF SERVICE 6.70/KWH Current ECA Schedule Facility charge At the City's available secondary supply. PAYMENT Bills are due when rendered, and become past due if not paid within 15 calendar days from date of issuance. ADDITIONAL TEMPORARY SERVICE CHARGES Labor (Regular Time) $60.00 minimum up to 1 hour. $60.00 for each additional hour (to be mea- sured to the nearest one-quarter hour) . Labor (Overtime) $75.00 minimum up to 1 hour. $75.00 for each additional hour (to be mea- sured to the nearest one-quarter hour). Premium time to be added where applica- ble. Transportation To be billed by hours or miles, as applicable, according to the estimated cost of operating the equipment. PAGE 31 Material Material that cannot be salvaged to be billed at Stores cost plus 25% and applicable sales tax. At the time a temporary service is re- moved or converted, any loss in the material installed due to negligence or willful action by the customer will be billed separately to customer at Stores cost plus 25% and sales tax. SPECIAL FACILITIES All services which require special facilities in order to meet the customer's service requirements shall be provided subject to special facilities rider. PRORATION OF UTILITY BILLS Billing for the Facility charge shall be based on 12 billings annually. Formula: Actual days in reading period x customer facility charge 30 days ENERGY CHARGE Billing for the energy charge shall be based on actual KWH con- sumption during the billing period. Formula: KWH consumption x Rate per KWH in rate block ENERGY COST ADJUSTMENT A charge per KWH of energy taken for fuel cost calculated in accordance with Schedule ECA. PAGE 32 SCHEDULE P1 INTERRUPTIBLE PRIMARY SERVICE (Effective 10/01/93) APPLICATION Applicable to all customers taking primary service at a firm power load exceeding 1,000 KW during the months of June, July, August and September and is, by contract, provided service subject to load interruptions. The City retains the right to limit the number of customers on this rate if the City's load reduction goals are met. NET MONTHLY CHARGE (1) Facility Charge (2) Energy Charge (3) Demand Charge (Estimated transmission firm) $70.00/30 days 0.200/KWH $ 4.15/KW (4) Energy Cost Adjustment Current ECA Schedule PAYMENT Bills are due when rendered, and become past due if not paid within 15 calendar days from date of issuance. MINIMUM BILLING An amount equal to the demand charge as calculated below but not less than one hundred percent (100%) of the maximum monthly KW similarly determined during the previous billing months of MAY through OCTOBER in the 12 months ending with the current month, nor LESS than 1,000 KW. TYPE OF SERVICE Interruptible primary voltage service (transformation equipment owned by customer) is available to any customer with a 12-month minimum monthly demand of 1,000 KW or greater. Interruptible pri- mary service rendered at one point on the customer's premises at a nominal voltage of 13,200 volts or 69,000 volts three-phase at the option of the utility. The primary voltage service customer shall own, operate, and maintain all facilities necessary to receive three phase primary voltage service and all transformation facilities required for conversion to utilization voltage. The City shall own, operate and maintain all metering facilities, either at primary or secondary voltage, at the Utility's option. Where the City elects to meter at secondary voltage, two percent shall be added to the demand PAGE 33 charge, the energy charge and the energy cost adjustment charge to account for transformer losses. DETERMINATION OF DEMAND The demand shall be determined by the KW supplied during the 15-minute period of maximum use during the current month as determined by City's demand meter, but not less than 100% of the maximum monthly KW similarly determined during the billing months of MAY through OCTOBER in the 12 months immediately preceding the current month, nor less than 1,000 KW. POWER FACTOR REQUIREMENTS AND ADJUSTMENTS_ The City reserves the right to make tests to determine the power factor of the user's installation served hereunder during periods of maximum demand for the monthly billing periods. Should the power factor so determined be below ninety (90%) percent, the demand for billing purposes will be determined by multiplying the uncorrected KW billing demand by ninety (90%) percent and dividing by the determined power factor. SPECIAL FACILITIES All service which requires special facilities in order to meet the customer's service requirements shall be provided subject to special facilities rider. PRORATION OF UTILITY BILLS (a) Billing for the Facility charge shall be based on 12 bill- ings annually. Formula: Actual days in reading period x customer facility charge 30 days (b) Billing for demand shall be calculated on a 30 day per month basis and prorated for longer or shorter billing periods. Formula: Actual days in reading period x KW Demand x Rate 30 days ENERGY CHARGE Billing for the energy charge shall be based on actual KWH consumption during the billing period. PAGE 34 Formula: KWH consumption x Rate per KWH ENERGY COST ADJUSTMENT A charge per KWH of energy taken for fuel cost calculated in accordance with Schedule ECA. PAGE 35 SCHEDULE AF ATHLETE FIELD (Effective 10/01/93) APPLICATION Applicable to all electric service metered at one point for use to light specified areas for athletic events where such electrical use will not occur between the hours of 2:00 P.M. and 7:00 P.M. for the months of June through September. NET MONTHLY RATE (1) Customer Facilities Charge Single Phase Three Phase (2) Energy Charge $20.00 per 30 days $30.00 per 30 days Billing months of June through September: All Other Hours (Off Peak) 3.754 per KWH 2:00 PM to 7:00 PM (Peak) 7.504 per KWH (Weekdays excluding City Holidays) Billing months of October through May: All hours (3) Demand Charge 3.754/KWH Billing months of June through September: All Other Hours (Off Peak) $1.10 per KW per 30 days 2:00 PM to 7:00 PM (Peak) $4.65 per KW per 30 days Billing months of October through May: All hours (4) Energy Cost Adjustment MINIMUM BILLING $1.10 per KW per 30 days Current ECA Schedule Facility Charge PAGE 36 TYPE OF SERVICE At the City's available secondary voltage and available phase. For use only between the hours of 7:00 P.M. and 2:00 P.M. from June through September and all hours from October through May. POWER FACTOR The City reserves the right to make tests to determine the power factor of the customer's installation served during periods of maximum demand or by measurement of the average power factor for the monthly billing period. If the power factor is below ninety percent, the demand for billing purposes will be determined by multiplying the uncorrected KW billing demand by 90% and dividing by the determined power factor. SPECIAL FACILITIES All services which require special facilities in order to meet customer's service requirements shall be provided subject to the special facilities rider. PRORATION OF UTILITY BILLS (a) Billing for the Facility charge shall be based on 12 bill- ings annually. Formula: Actual days in reading period x customer facility charge 30 days (b) Billing for demand shall be calculated on a 30 day per month basis and prorated for longer or shorter billing periods. Formula: Actual days in reading period x KW demand x Rate 30 days ENERGY CHARGE Billing for the energy charge shall be based on actual KWH con- sumption during the billing period. Formula: KWH in rate block x Rate per KWH in rate block ENERGY COST ADJUSTMENT A charge per KWH of energy taken for fuel cost calculated in accordance with Schedule ECA. PAGE 37 SCHEDULE ES STANDBY SUPPLEMENTARY AND MAINTENANCE SERVICE (Effective 10/01/93) APPLICATION Applicable in all areas served by the City to customers who: (1) own and/or operate an electric power generation facility mainly used for non-emergency uses and which has a total nameplate or effective capacity (whichever is lesser) of fifty (50) KW or more in parallel with the City's electric system for the purpose of generating power for the custom- er's own consumption, and (2) employ equipment which is compatible with the City's elec- tric system at the customer's delivery point and which will cause no damage to the City's electric system or equipment or present undue hazards to City personnel, and (3) own and/or operate an electrical generating facility which has been certified annually by a registered professional engineer practicing in the utility or Independent Power Production Industry to be a functioning and reliable generating facility. (4) operate an electrical power generating system at least 6,500 hours annually. (5) execute an agreement for interconnection and parallel operation with the City. INTERCONNECTION COSTS The customer shall reimburse the City for any equipment or facilities required as a result of the installation by the customer of generation in parallel with the City's electric system. The customer shall pay all costs of the City to extend its facilities or modify them at the time of interconnection, or at some future time in order to permit parallel operation of the customer's facility. TYPE OF SERVICE The City shall supply alternating current at sixty (60) cycles and at the voltage and phase of the City's electric system most available to the location of the customer. The primary voltage customer shall own, operate and maintain all facilities necessary to receive three phase primary voltage service and all transforma- tion facilities required for conversion to utilization voltage. The City shall own, operate and maintain all metering facilities, PAGE 38 either at primary or secondary voltage, at the City's option. Where the City elects to meter at secondary voltage, the secondary energy and on- peak demand charges shall apply. NET MONTHLY RATE (1) Facility Charge (2) Demand Charges: On-Peak Demand System Demand (3) Energy Charges: Non-Emergency Energy Emergency Energy (5) Energy Cost Adjustment MINIMUM BILLING Primary Service $60.00/30 days $11.35/KW $ 4.15/KW 0.24/KWH 5.24/KWH Per Sch ECA Secondary Service $25.00/30 days $11.35/KW $ 4.15/KW 0.54/KWH 5.34/KWH Per Sch ECA The minimum monthly billing shall be the higher of the follow- ing: (1) The sum of the Customer Facility Charge, the On-Peak Demand Charge, and the System Demand Charge; or (2) A charge of $1.00 per KVA of installed transformer capaci- ty. DETERMINATION OF ON-PEAK DEMAND The on-peak demand shall be determined by the KW demand supplied by the City during the fifteen (15) minute period of maximum use during the on-peak hours as recorded by the City's demand meter and adjusted for power factor, but not less than one hundred percent (100%) of the maximum on-peak demand which occurred during the billing months of June through September in the twelve (12) months immediately preceding the current month. DETERMINATION OF ON-PEAK DEMAND - COGENERATION UNITS NOT OPERATING AND CUSTOMER'S PEAK DID NOT CONTRIBUTE TO CITY'S ANNUAL SYSTEM PEAK If a customer's cogeneration unit(s) is/are off during peak hours, and the customer's peak did not contribute to the City's annual system peak, and the cogeneration unit is one (1) MW or larger, then the nameplate rating of the customer's unit(s) shall be deducted from the peak demand. PAGE 39 The customer shall be charged the appropriate'on-peak demand charges for the KW supplied by the City for the succeeding twelve (12) months. DETERMINATION OF SYSTEM DEMAND The system demand shall be determined by the sum of the KW demand supplied during the fifteen (15) minute period of maximum use as recorded by the City's demand meter, plus the KW nameplate rating(s) of the customers generator(s). In no event shall the system demand be less than seventy per- cent (70%) of the maximum on-peak demand similarly determined dur- ing the billing months of June through September in the twelve (12) months immediately preceding the current month. DETERMINATION OF NON-EMERGENCY ENERGY All energy supplied to customers whose generating units are less than one (1) MW capacity. DETERMINATION OF EMERGENCY ENERGY Emergency energy is all energy supplied by the City during peak hours of operation to displace energy normally supplied by custom- er's one (1) MW or larger unit. POWER FACTOR PENALTY The City reserves the right to determine the power factor of the customer's installation served during periods of maximum demand or by measurement of the average power factor for the monthly bill- ing period. If the power factor is below ninety percent (90%) dur- ing on-peak hours, the demand for billing purposes will be deter- mined by multiplying the uncorrected KW billing demand by 90% and dividing by the determined power factor. The formula is as fol- lows: Unadjusted billing demand x .9 Determined power factor - DEFINITION OF ON-PEAK HOURS The City's on-peak hours, for the purpose of this rate sched- ule, are designated as being from 2:00 P.M. to 7:00 P.M. each Monday through Friday. DEFINITION OF OFF-PEAK HOURS The City's off-peak hours, for the purpose of this rate sched- ule, shall be all hours not designated as on-peak hours. PAGE 40 SPECIAL FACILITIES All services which require special facilities in order to meet customer's service requirements shall be provided subject to the special facilities rider. PRORATION OF UTILITY BILLS (a) Billing for facility charge shall be calculated on a 30 day per month basis and prorated for longer or shorter billing periods using the following formula: Actual days in reading period x customer facility charge 30 days (b) Billing for demand shall be calculated on a 30 day per month basis and prorated for longer or shorter billing periods using the following formula: Actual days in reading period x KW Billing Demand x Rate 30 days ENERGY CHARGE Billing for energy shall be based on actual KWH consumption during the billing period. Formula: KWH in rate block x Rate per KWH in rate block CREDIT FOR ENERGY DELIVERED INTO CITY'S SYSTEM DURING ON-PEAK HOURS If Customer-produced energy is fed back into the City's system during on-peak hours, an amount equal to fuel cost calculated in accordance with Schedule ECA, as applicable to such energy is cred- ited monthly, provided that Customer has paid the City for neces- sary added metering, protective and other equipment as determined by the City. CREDIT FOR ENERGY DELIVERED INTO CITY'S SYSTEM DURING OFF-PEAK HOURS -If Customer-produced energy is fed back into the City's system during off-peak hours,- an-amount. equal .to 0.013 2 8 per KWH _ (.f or_ _ _ each KWH delivered back into the City's system) will be credited monthly, provided that Customer has paid the City for necessary added metering, protective and other equipment as determined by the city. PAGE 41 ENERGY COST ADJUSTMENT A charge per KWH of energy taken for fuel cost calculated in accordance with Schedule ECA. PAYMENT Bills are due when rendered, and become past due if not paid within twenty (20) calendar days from date of issuance. LATE PAYMENT CHARGES Bills are considered past due if not received within twenty (20) calendar days and shall be accessed a late payment charge of one and one-half percent (1.5%) per month on any unpaid balance. PAGE 42 SCHEDULE DL DECORATIVE LIGHTING (Effective 10/01/93) APPLICATION Applicable to any customer on the perimeter of the square ser- ved by the City's electric distribution system for outdoor area lighting when such lighting facilities are operated as an extension of the City's distribution system. NET MONTHLY RATE (1) Facility Charge (2) Energy Cost Adjustment $3.80/30 Days Current ECA x Monthly Bulb Watt- age Factor, based on 415 KWH per Customer TYPE OF SERVICE The City shall furnish, install, maintain and deliver electric service to automatically controlled lighting fixtures conforming to the City's standards and subject to its published rules and regula- tions. The service is provided between dusk and midnight. PAYMENT Bills are due when rendered, and become past due if not-paid' within-15 calendar days from date of issuance. SPECIAL FACILITIES All service which requires special facilities in order to meet the customer's service requirements shall be provided subject to special facilities rider. PRORATION OF UTILITY BILLS Billing for the Facility Charge shall be based on 12 billings annually. Formula: Actual days in reading period x Facility Charge 30 days ENERGY COST ADJUSTMENT -A charge per KWH of energy taken for fuel cost calculated in accordance with Schedule ECA. PAGE 43 4- i SCHEDULE IDR INDUSTRIAL/ECONOMIC DEVELOPMENT RIDER AVAILABILITY This rider is available to the customers who receive service from Rate Schedules GSS, GSL, or TGS. APPLICATION This rider is available to electric service supplied at any one location and measured through one meter. This is for firm electric service applicable to new customers and existing customers as de- scribed below. (1) New customers whose electric service represents demand not previously served by the City at any location in the City's service area in the last 12 months and where such metered demand is in excess of 200 KW. (2) Existing customers served under Rate Schedules GSS or GSL who add additional metered demand of at least 200 KW on top of their existing level of demand. This additional load will be separately metered. Under no circumstances may this rider be used to reduce the current amount of other firm service billed to the customer. Dur- ing the term of this agreement, the customer may not reduce other firm service peak demand. NET MONTHLY RATE The customer shall be charged under the appropriate applicable rate schedules, except that the monthly billing demand or system demand will be adjusted in accordance with the following table: Reduction to Billing Time Period Demand or System Demand First Year 50% Second Year 40% Third Year 30% Fourth Year 20% Fifth Year 10% CONTRACT PERIOD The term of the contract will be a five-year period. PAGE 44 l SCHEDULE TS THERMAL STORAGE INCENTIVE (Effective 10/01/93) APPLICATION Applicable to any customer who agrees to be on Time-of-Use rate for five (5) years and who has a thermal storage facility of a min- imum storage capacity of 500,000 BTU. THERMAL STORAGE INCENTIVE PAYMENTS First 500 KW shifted $250/KW to off-peak hours Additional KW shifted $125/KW to off-peak hours Thermal storage incentive payments shall be made to qualifying customers based-on the following method: A design shall be submitted to the Director of Electric Utili- ties for approval. The thermal storage equipment shall be checked for input electric demand (KW) and output capacity (BTU). The sys- tem shall be limited for incentive payment to a maximum of 12,000 BTU per 500 square feet for the conditioned area of the facility to be served. Upon completion, the input-output of the thermal storage units will be measured by the City of Denton. The customer may observe and verify all information and calculations for the actual size of the facility. Auxiliary equipment used to circulate fluid or air handlers which would operate under normal peak periods will not be included in calculating the KW=load for incentive payments. PAGE 45 SCHEDULE UPS UNINTERRUPTIBLE POWER SUPPLY (Effective 10/01/93) APPLICATION Applicable to any customer who, by written agreement, receives service for uninterruptible power supply for a computer or other electrical equipment. . Not applicable for resale service in any event, nor to tempo- rary or standby service except in conjunction with applicable rider. NET MONTHLY RATE (1) Customer Facility Charge: 250 W Power Standby Unit $ 7.70/30 days 1,200 W Power Standby Unit $31.55/30 days (2) Installation Charge $25.50 For any W Power Standby Unit other than above, the monthly customer charge will be based on the following formula: (l)- Monthly Charge: 5% of Annual Maintenance Cost PLUS 12 months 6% Annual Return of Investment PLUS 12 months 8% Interest on a 5 Year Life TYPE OF SERVICE The City shall furnish, install, maintain an automatically controlled alternating current power backup unit conforming to the City's standards and subject to its published rules and regula- tions. PAYMENT _ Bills are due when rendered, and become past due if not paid within 15 calendar days from date of issuance. SPECIAL FACILITIES All services which require special facilities in order to meet customer's service requirements shall be provided subject to the special facilities rider. PAGE 46 PRORATION OF UTILITY BILLS (a) --Billings for the Facility charge shall be based-on 12 billings annually. Formula: Actual days in reading period x customer facility charge 30 days PAGE 47 SCHEDULE ECA ENERGY COST ADJUSTMENT (Effective 10/01/93) ENERGY COST ADJUSTMENT All monthly KWH charges shall be increased or decreased by an amount equal to "X" cents per KWH, to be known as the energy cost adjustment (ECA). The ECA shall be computed in the months of March and September to -.be.applied to the-following periods of April through September and October through March respectively. The City shall in no case change the energy cost adjustment more than twice in either of the six (6) months periods. The ECA shall be calculated by the following formula: ECA (Winter) = Projected energy cost for winter months Projected KWH sales for winter months ECA (Summer) Projected energy cost for summer months Projected KWH sales for summer months The above formula results in- Winter1993/94 and estimated Summer 1994 ECA's as follows: ECA (Winter) = 1.904/KWH ECA (Summer) = 1.904/KWH In the event that actual plus estimated cumulative costs of fuel, variable costs of Texas Municipal Power Agency (TMPA) energy and purchased energy (excluding TMPA's fixed charges) are greater than or less than the actual and projected ECA revenues by $1,000,000 during the October through March or April through September period, the City may recompute the Energy Cost Adjustment and re- establish an ECA that collects or returns such difference over the next six months of the year. Such change in ECA shall be applied evenly to each month during the six month period. PAGE 48 SCHEDULE APR APPLIANCE REBATE (Effective 10/01/93) Application/Program Summary The City of Denton Utility Department is offering cash pay- ments to customers who purchase and install high efficiency air conditioners or heat pumps in new or existing residential or com- mercial facilities. - The program's objective is to reduce energy demand and con- sumption, thereby saving customers dollars on their utility bills and reducing the peak load of the City of Denton's electric system. Program Guidelines 1. All installations must be for accounts served by the City of Denton Utility Department and must meet all applicable national, local, and manufacturers' codes and specifica- tions. 2. To qualify for a rebate, equipment must be new when in- stalled. 3. All equipment must be purchased. No leased or lease/ purchased equipment will qualify for a cash rebate. 4. Installations must be made by licensed contractors and/or dealers. 5. No rebate will be paid on a partial replacement of an air conditioner. The compressor, condenser and the evapora- tor coil must be replaced to qualify for a rebate. 6. Payments for residential central cooling systems, which include apartments and mobile homes, will be limited to a capacity based on a minimum of 500 conditioned square feet per ton. 7. The conditioned area in square feet is required on each residential central system request for payment. 8. The. rebate will be paid to the purchaser of the qualify- ing equipment upon verification of compliance with program guidelines. 9. Requests for payment must be received by the Director of Electric Utilities within 60 days of installation. PAGE 49 10. Equipment and installation are subject to inspection by the City's Building Inspection Department before final approval for payment is issued. 11. The Appliance Rebate Program guidelines and payments are subject to change without notice. 12. The Appliance Rebate Program may be discontinued without prior notice at any time by the City of Denton. I. GENERAL PROCEDURES A. Application To determine who qualifies for a rebate, an appli- cation for rebate must be completed and sent to the Director of Electric Utilities within 60 days of installation of the equipment. Participating dealers have rebate application forms and will complete these forms for the purchaser. It is the purchaser's responsibility to see that the dealer completes the form and submits it to the Director of Electric Utilities. B. Inspections Installations of central systems will be inspected by the City's Building Inspection Department and must be approved before rebates will be processed. C. Payments to Participants Cash payments will be made to the purchaser of the qualifying equipment. Participating retail equip- ment dealers will receive a cash payment of $20 per unit for the sale of window units, central air con- ditioning systems, or heat pumps to offset their cost for properly filling out the applications for purchasers. Program participants are responsible for submitting the correct information. The Utili- ty Department will not issue any additional payment unless the payment was incorrect due to a mistake in processing by a City employee. 1. The twenty dollar ($20.00) payments to dealers will be made only if they supply the qualify- ing equipment to the customer or builder who is paying for the installation of the equip- ment. Dealers and purchasers may be denied payment for failure to follow program guide- lines such as: failing to supply correct square footage or SEER/EER figures; installing equipment which is not new; replacing part of PAGE 50 a split-system; or failure to fill out rebate forms properly. 2. Payments will be made to customers who pur- chase and install new qualifying equipment. If a tenant purchases and installs qualifying equipment, the payment is made to the tenant. If the owner of rental-property purchases and installs qualifying equipment, the payment is made to the owner. If the purchaser of a mobile or custom home selects and pays for a qualifying unit, the purchaser will receive the rebate. II. CENTRAL ELECTRIC AIR CONDITIONERS AND HEAT PUMPS -A. A new condensing unit with an inside evaporator coil will qualify if matched, as specified, in the current issue of the ARI Directory of Certified Air Conditioners and Air Source Heat Pumps and the unit meets the minimum ratings as specified in the 1992 Appliance Rebate Program. If the unit -is -not-in the current ARI Directory, the manufacturer's latest data approved for publication will be ac- cepted. If the unit is not in the current ARI Directory or data approved for publication, the average of the high and low SEER/EER coil only, not including blower coil, will be accepted as listed in the current ARI Directory. B. Computer simulations may be used if ratings are not listed in the current ARI Directory, provided the following criteria are met: 1. Systems using mix-matched coils must meet all established program guidelines to qualify for a rebate. 2. The computer simulations must be signed, cer- tified, and dated by a registered professional engineer and an officer of the company making the submittal. 3. The engineer who certifies a simulation must attest to the accuracy of the input data, the validity of the calculation procedure - used, and that the results are in accordance with D.O.E. approved methodology. 4. A complete set of the input data and an indi- cation of the source of the data must accompa- ny the simulated ratings. PAGE 51 5. The simulated ratings must be based on the condensing unit's tested combination as listed in the current ARI Directory or latest data approved for publication and identified' by the correct model numbers of both the condensing unit and coil as listed in the current ARI Directory. 6. Simulated ratings must not exceed 105% of the SEER rating of the tested system used as a base. 7. An open file of computer simulations will be maintained at the Energy Management Office. Supplying erroneous ratings or data can lead to disqualification of those involved from further program participation. C. Program Capacity and Payment Formula 1. The maximum allowable BTU per hour capacity eligible for a residential rebate is deter- mined by dividing the square footage of the conditioned area by 500 and multiplying by 12,000. Example: The Program Capacity for a 1,500 square foot house is: 1,500 = 3.0 x 12,000 = 36,000 BTUH 500 The City will pay a rebate on a unit that meets program efficiency standards and is sized at 36,000 BTUH or less. 2. Actual payment will be determined by dividing the BTUH of the installed unit (up to, and including the Program Capacity) by 12,000 and multiplying by the incentive. The incentive amounts and SEER ratings are refer- enced on page 5 and are incorporated herein as if fully set forth at length: Example A: A person in a -1,500 square foot house installs a 30,000 BTUH central air conditioner with a SEER rating of 12.0. 1,500 = 3 x 12,000 = 36,000 Program Capacity 500 PAGE 52 z 30,000 = 2.5 x $100/ton= $250.00 Rebate Amount 12,000 Example B: A person in a 2,000 square foot house installs a 60,000 BTUH central air conditioner with a SEER rating of 12.0. 21000 = 4 x 12,000 = 48,000 Program capacity 500 48,000 = 4 x $100/ton = $400 Rebate Amount 12,000 Example C: A person in a 2,000 square foot house installs a 60,000 BTUH central heat pump with a SEER rating of 12.0. 2,000 = 4 x 12,000 = 48,000 Program Capacity 500 48,000 = 4 x $100/ton = $400 Rebate Amount Minimum SEER/EER Central Air Conditioning Rating Incentive Single Phase (SEER) 12.0 $100/ton*t Three Phase-(EER) 12.0 $100/ton Central Heat Pumps Single Phase (SEER) 12.0 $100/ton Three Phase (EER) 12.0 $100/ton Room Air Conditioners 10.0 $ 50/unit Room Heat Pumps 10.0 $ 50/unit Geothermal Heat Pumps 12.0 $500/unit * Refer to 111992 Appliance Rebate Program: Methods Used in Determining Equipment Efficiency and Eligibility" t' For calculation purposes, one ton equals 12,000 BTUH PAGE 53 SCHEDULE ACR AIR CONDITIONER CYCLING REBATE (Effective 10/01/93) APPLICATION -This schedule is available to any -customer- of the City of Denton Utility who is served and billed pursuant to rate schedules R-1, R-2, GSS/GSL and G1, has a central air conditioning system with a minimum connected compressor output of 2.5 tons and who agrees to permit the utility to install a control device to his or her air conditioning system. The device will enable the utility to control the operation of the air conditioner compressor-during periods of the utility's peak load and emergency conditions. The utility shall have the right to interrupt service to the compressor unit for approximately seven and one-half minutes of each thirty minute interval during peak load conditions. Peak load conditions are defined as being- from-June 1-through- September 3.0_ of.. each year. TERMS AND CONDITIONS A customer may apply for this schedule at any time by applying and entering into a contract with the City of Denton Utility. The contract shall be for a term of one year and shall be renewable for additional one year -terms. Upon approval of the application and installation of the load reduction device, the customer shall receive a monthly credit on his or her utility bill, the amount of which shall be based upon the customer's compressor output (tons). The start date for receiving credit shall be the date the load reduction device is installed on the compressor and tested for proper operation. The amount of the credit is based upon thirty (30) day billing cycle and prorated according to the start date. The amount of credit on an eligible customer's bill shall be deter- mined in the following manner: Compressor Output in Tons 2.5 to 5.0 All over 5.0 Credit per Billing Cycle $10.00 $ 2.00 per ton Any credit on a customer's electric bill shall not exceed fifty percent (50%) of said bill. The Utility shall rebate applicable credits to customers in the months of June, July, August and September. PAGE 54 SCHEDULE VLR VOLUNTARY LOAD REDUCTION (Effective 10/01/93) APPLICATION This program is available to customers who agree to reduce peak demand by a minimum of 100KW upon request by the City. Customers who execute contracts agreeing to interrupt power under the terms and conditions set forth in the attached sample contracts are eligi- ble for credits on their utility bills. TERMS AND CONDITIONS Electric utility bill incentives shall be provided as set forth in the attached sample contract agreements. Customers agreeing to reduce demand between 2:00 p.m. and 7:00 p.m. receive an incentive of twenty-four dollars ($24.00) per KW demand. The customer will be charged according to the current rate schedule for the months of July, August, and September of each year. A credit shall be applied to the customer's October bill. PAGE 55 J (SAMPLE) AGREEMENT FOR TEMPORARY REDUCTION IN DEMAND The County, through City of Denton, Texas, a Home Rule City situated in Denton Texas, hereinafter called "CITY," acting herein by and its Executive Director of Utilities, Robert E. Nelson and whose address is 11 hereinafter called "CUSTOMER," hereby mutually agree as follows: 1. APPLICATION: This Agreement is applicable only when CUSTOMER receives service during the months of July, August, and September, 1994, when service is subject to load reductions of a minimum of one-hundred kilowatts (100 KW) upon two hours notifica- tion by telephone by CITY'S Representative. The CITY and CUSTOMER have determined the estimated peak loads for the months of July, August, and September, 1994, for CUSTOMER to be the same as the actual peak for the months of July through-September of 1993; Peak Demand: KW Service Address: 2. DEFINITIONS: The following definitions shall apply to this Agreement: Peak KW Demand: The actual peak KW usage for the months of July, August, and September, 1993, based on historical billing records. Maximum Demand During Reduction: Customer's maximum (or peak) demand KW that occurs during reduction (s) requested by the city. Demand Reduction: Peak KW Demand less Maximum Demand Dur- ing Reduction. Utility's Peak Day: The day on which the maximum KW demand is placed on the entire electrical system. 3. SERVICES TO BE PERFORMED: The City has a public interest in reducing the system peak KW in order to maximize the efficiency of its utility system and thus, agrees to pay CUSTOMER twenty four ($24.00) dollars per KW demand for a one time reduction of at least one-hundred KW (100KW) during the months of July, August, and September, 1994. CUSTOMER calculates the Maximum Estimated Reduc- tion in Demand to be an estimated KW. The actual reduc- tion shall be based upon measurements taken by City's representa- tive. CITY-agrees to monitor its_system_load and determine if a reduction in peak KW is required. CITY shall notify CUSTOMER by telephone not later than twelve noon of a day if such reduction is- required during that day. CUSTOMER agrees'to acknowledge such re- I Y quest and reduce its load for that day between the hours of 2:00 o'clock p.m. and 7:00 o'clock p.m. 4. GENERAL BILLING INFORMATION: CUSTOMER will be charged according to the current rate schedule applicable to the CUSTOMER for the months of July, August, and September, 1994. A credit shall be -applied to CUSTOMER'S October, 1993 bill, which shall be calculated as follows: Peak KW Demand July-September, 1993 KW LESS Maximum Demand During Reduction(s) ( xx ) KW Total Demand Reduction xx KW x 24.00 Total Credit: $ xx.xx 5. MISCELLANEOUS: CUSTOMER is granted a one-time exemption whereby CUSTOMER need not reduce demand by at least 100 KW from its peak KW demand. However, if the CUSTOMER's one-time exemption occurs on the same date as the Utility's Peak Day, this contract becomes void and shall terminate immediately. If the CUSTOMER fails, when requested, to reduce its peak demand more than 100 KW on more than one occasion, this Agreement becomes void and shall terminate immediately without further notice by the City. 6. TERM: This Agreement is in effect for the period beginning July 1, 1994 and ending at midnight, September 30, 1994. EXECUTED this day of CUSTOMER (Name) Address City/State/Zip Code Telephone Number Account Number Meter Number Contact Person , 1994. CITY OF DENTON, TEXAS BY: R. E. NELSON, EXECUTIVE DIRECTOR OF UTILITIES APPROVED AS TO LEGAL FORM: DEBRA A. DRAYOVITCH, CITY ATTORNEY BY: SPECIAL FACILITIES RIDER (1) All service shall be offered from available facilities. If a customer service characteristic requires facilities and devices which are not normally and readily available at the location which the customer requests service, then the City shall provide the service subject to paragraph 2 of this schedule. (2) The total cost of all facilities reburied to meet the custome- r's load characteristics which are incurred by the City shall be subject to a special contract entered into between the Utility and the customer. This contract shall be signed by both parties prior to the City providing service to the customer. _ SECTION II. That the Executive Director of Utilities is hereby authorized to execute agreements with electric utility customers in the form and type set forth herein as an attachment to Schedule . VLR. SECTION III. That if any section, subsection, paragraph, sen- tence, -clause,- phrase or word in this ordinance, or application thereof to any person or circumstances is held invalid by any court of competent jurisdiction, such holding shall not affect the valid- ity of the remaining portions of this ordinance, and the City Coun- cil of the City of Denton, Texas, hereby declares it would have enacted such remaining portions despite any such invalidity. SECTION IV. That the Schedule of Rates herein adopted shall be effective, charged and applied to all energy consumption occurring on or after October 1, 1993. , 1993. J9-;&,M;m PASSED AND APPROVED this the LiLeday of ATTEST JENNIFER WALTERS, CITY SECRETARY BOB CASTLEBERRY, BY: APPROVED AS TO LEGAL FORM: DEBRA A. DRAYOVITCH, CITY ATTORNEY